PCR HH350 Manual

The document is a technical manual for the HH-350B Plant Power Supply Cabin, detailing its design, operation, and maintenance procedures. It includes information on the plant's power supply system, components, calibration, and safety protocols. The manual serves as a comprehensive guide for qualified personnel to ensure proper usage and maintenance of the power supply system.

Uploaded by

rafael
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views91 pages

PCR HH350 Manual

The document is a technical manual for the HH-350B Plant Power Supply Cabin, detailing its design, operation, and maintenance procedures. It includes information on the plant's power supply system, components, calibration, and safety protocols. The manual serves as a comprehensive guide for qualified personnel to ensure proper usage and maintenance of the power supply system.

Uploaded by

rafael
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 91

Page 1 di 91

Date 10/06/11
Ref. PCR-003A

Purchaser data

Company: PETROWORKS

Address:

Plant:

Design: PCR-003A

HH-350B PETROWORKS Plant Power Supply Cabin


Automation design realized by: Drillmec S.p.A.

Issues: Preliminary Executive As executed


Rev. Date View Rev. Date View Rev. Date View
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
Page 2 di 91
DESIGN Date 10/06/11
HH350B Plant Power Supply System Ref. PCR-003A

CHAPTER 1 SYSTEM DEFINITION ................................................................................................................................................... 4


1.1) DESCRIPTION OF THE PLANT OPERATION .................................................................................................................................. 4
1.2) DESCRIPTION OF THE CABIN AND ITS PARTS ............................................................................................................................. 6
1.3) REFERENCE ELECTRIC NORMATIVES ......................................................................................................................................... 6
1.4) SAFETY RULES ADOPTED .......................................................................................................................................................... 7
CHAPTER 2 DESIGN TECNICA DATA ............................................................................................................................................ 11
2.1) REFERENCE ELECTRIC DATA .................................................................................................................................................. 11
2.2) DESIGN ELECTRO-TECHNICAL CALCULATIONS ....................................................................................................................... 11
2.2.a) Calculation of presumed Icc downstream the Generators .......................................................................................... 11
2.2.b) Calculation of presumed Icc downstream the Generators .......................................................................................... 12
2.2.c) Calculation of presumed Icc on Bars ........................................................................................................................... 12
2.2.d) Raceway data ................................................................................................................................................................ 13
CHAPTER 3 DETAIL DESCRIPTION OF CABIN PANELS ................................................................................................................. 16
3.1) PLC PANEL COMPOSED BY: .................................................................................................................................................... 16
3.1.a) Panel – 47017038 - PLC ............................................................................................................................................... 16
3.2) POWER DISTRIBUTION PANEL COMPOSED BY: ......................................................................................................................... 16
3.2.a) Column - 470170570 – generator 1 inlet, trasformer power supplì auxiliary generator inlet and trasformer output ..
....................................................... 16
3.2.b) Column - 47017021- arrival generator 2 controls the generator 2, fused power inverter fuse disconnector MP1A
MP1B ............................................................. 16
3.2.c) Column - 47017022 - arrival generator 3 controls the generator 3, fusedpower inverter fuse disconnector MP2A
MP2B ............................................................ 17
3.2.d) Column - 47017023 - arrival generator 4, controls generator 4, switch upstream transformer 1000kVA, switch
downstream trasformer 1000kVA ................................................................ 17
3.2.e) Column - 47017024 - arrival generator auxiliary, switch upstream transformer 250kVA, switch downstream
trasformer 250kVA ...................................................................... 17
3.3) SOCKET AND DISTRIBUTION PANELS 460V - 400/230V – 208/110 COMPOSED BY: ................................................................. 18
3.3.a) Column 47017027- Switches downstream and upstream transformer 75kVA and soket 460 - 208/110 .............. 18
3.3.b) Column 47017026- Box socket and switches 400/230V .............................................................................................. 18
3.4) ELECTRIC BOARD SOFT-STAR DEPARTURES OF ENGINE:.......................................................................................................... 18
3.4.a) SOFT-START board switch and motor startes 75kW – 47017025.............................................................................. 18
3.5) PIPE HANDLER ELECTRIC BOARD: ........................................................................................................................................... 18
3.5.a) Pipe handler electric board - 47017028 ....................................................................................................................... 18
3.6) INVERTER PANEL COMPOSED BY:............................................................................................................................................ 19
3.6.a) Panel - 47500504 inverter MP1A – MP2A and 47500503 inverter MP1B - MP2B ................................................... 19
3.7) CONFIGURATION OF CABIN CONTROL SYSTEM ........................................................................................................................ 19
DETAIL (MANUAL OPERATION / AUTOMATIC / PLC / COMMAND PANEL) .................................................................. 19
3.7.a) GENERATORS............................................................................................................................................................. 19
3.7.b) MUD PUMPS ............................................................................................................................................................... 20
3.7.c) MAIN HYDRAULIC POWER UNIT (HPU) ............................................................................................................... 21
3.7.d) Centrifugal pump of mud transfer (DESANDER and DESILTER) .......................................................................... 22
3.7.e) Centrifugal pump (SUPERCHARGING PUMP 1 & 2, TRIP TANK PUMP 1 & 2) ................................................. 23
3.7.f) Mixing pump (1-2-3-scorta) .......................................................................................................................................... 24
3.7.g) Water pump (1-2-3-4) ................................................................................................................................................... 25
3.7.h) Mud Degasser ............................................................................................................................................................... 26
CHAPTER 4 CALIBRATION ........................................................................................................................................................... 28
4.1) CALIBRATION OF POWER SUPPLY SWITCHES FROM MAIN GENERATORS .................................................................................. 28
4.1.a) Setting of overload intervention ................................................................................................................................... 28
4.1.b) Setting of delayed short-circuit intervention ................................................................................................................ 28
4.1.c) Setting of immediate short-circuit intervention ........................................................................................................... 28
4.1.d) Setting of intervention of differential “G” (in case of failure at ground) ................................................................... 29
4.1.e) Setting phase current unbalance .................................................................................................................................. 29
4.1.f) Setting protection against overtemperature inside the relay “OT” .............................................................................. 29
4.1.g) Setting the protection of closed circuit “MCR” ........................................................................................................... 29
4.2) CALIBRATION OF POWER SUPPLY SWITCHES FROM AUXILIARY GENERATOR ........................................................................... 30
4.2.a) Setting of overload intervention ................................................................................................................................... 30
42.2b) Setting of instantaneous short-circuit intervention .................................................................................................... 30
4.3) CALIBRATION OF TRANSFORMER 1000KVA POWER SUPPLY SWITCHES ................................................................................. 30
4.3.a) Setting of overload intervention .................................................................................................................................. 30
4.3.b)Setting of instantaneous short-circuit intervention “I” ................................................................................................ 30
Page 3 di 91
DESIGN Date 10/06/11
HH350B Plant Power Supply System Ref. PCR-003A

4.4) CALIBRATION OF TRASFORMER 1000KVA OUTPUT SWITCHES ............................................................................................... 31


4.4.a) Setting of overload intervention ................................................................................................................................... 31
4.4.b)Setting of instantaneous short-circuit intervention “I” ................................................................................................ 31
4.4.c)Setting of overload intervention..................................................................................................................................... 31
4.4.d)Setting of instantaneous short-circuit intervention “I” ................................................................................................ 31
4.5) SETTING OF INSULATION CONTROLLER ................................................................................................................................... 32
4.5.a) Setting of resistance thresholds .................................................................................................................................... 32
CHAPTER 5 SPECIAL OPERATIONS .............................................................................................................................................. 33
5.1) GESTIONE POWER-LIMIT. ....................................................................................................................................................... 33
CHAPTER 6 ANOMALIES .............................................................................................................................................................. 34
6.1) LIST OF THE ANOMALY CODES AND RELEVANT POSSIBLE CAUSES .......................................................................................... 34
CHAPTER 7 SUPERVISION PAGES ................................................................................................................................................. 67
7.1) SUPERVISION PAGES ............................................................................................................................................................... 67
7.1.a) Page start....................................................................................................................................................................... 68
7.1.b) Page General Lay-Out .................................................................................................................................................. 68
7.1.c) Pages Generator ............................................................................................................................................................ 69
7.1.d) H.P.U. Page................................................................................................................................................................... 70
7.1.e) Mud Pump Page ............................................................................................................................................................ 71
7.1.f) Tanks page ..................................................................................................................................................................... 72
7.1.g) Pagina agitatori ........................................................................................................................................................... 73
7.1.h) Profibus Network Diagnostics Page............................................................................................................................. 74
7.1.i) Page display profibus nodes .......................................................................................................................................... 75
CHAPTER 8 PROCEDURES FOR ELECTRICAL SAFETY ................................................................................................................. 76
8.1) INVERTER ........................................................................................................................................................................... 76
8.2) GENERATORS PRAMAC ........................................................................................................................................................... 76
8.3) MANIPOLATORE ASTE ..................................................................................................................................................... 76
8.4) POMPE 12T1600AC ............................................................................................................................................................. 77
8.4.a) Pump 1 .......................................................................................................................................................................... 77
8.4.b) Pump 2 .......................................................................................................................................................................... 78
8.5) MAIN HYDRAULIC POWER UNIT (HPU) ........................................................................................................................ 79
8.6) DRILLING RIG .................................................................................................................................................................... 79
8.7) SNUBBING HPU .................................................................................................................................................................. 79
8.8) MIXING PUMPS .................................................................................................................................................................. 80
8.9) MUD DEGASSER ................................................................................................................................................................ 80
8.10) TRIP TANK PUMPS ........................................................................................................................................................... 80
8.11) WATER PUMP ................................................................................................................................................................... 80
8.12) MUD PUMPS 12T1600AC SUPERCHARGING PUMPS ................................................................................................. 81
8.13) ELECTRAGITATORS........................................................................................................................................................ 81
8.14) AIR COMPRESSOR ........................................................................................................................................................... 81
8.15) SHALE SHAKER................................................................................................................................................................ 81
8.16) BOP ACCUMULATOR ...................................................................................................................................................... 81
8.17) MUD TANK ELECTRIC PANELS .................................................................................................................................... 82
8.18) RESERVE AND SERVICES .............................................................................................................................................. 82
8.19) POWER TRANSFORMER ................................................................................................................................................. 82
8.20) AIR-CONDITIONERS........................................................................................................................................................ 82
CHAPTER 9 ANNEXES................................................................................................................................................................... 83
SCHEDA TECNICA GENERATORI PRINCIPALI .................................................................................................................................. 83
SCHEDA TECNICA TRASFORMATORE ............................................................................................................................................. 84
SCHEDA TECNICA SISTEMA A SBARRE 600V .................................................................................................................................. 85
SCHEDA TECNICA SISTEMI A SBARRE QUADRO PRESE 400V.......................................................................................................... 85
INVERTER MOTORI UTENZE PRINCIPALI 600V .............................................................................................................................. 86
COMPONENTI IMPIANTO ILLUMINAZIONE ...................................................................................................................................... 88
ALTRA DOCUMENTAZIONE ............................................................................................................................................................ 91
Page 4 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Chapter 1 System definition


This technical manual describes the components and the operating procedures to
respect for the utilization of the power supply cabin of HH-300 plant.
The plant power supply system consists in four 1500kVA power generators, one 250kVA
auxiliary electric set, a PCR cabin containing the manoeuvre switches and the power
transformer to provide the necessary voltage to all equipment. The whole high-automation
system in the Power Control Room is supervisioned by means of proper touch-screens.
System flexibility is ensured by fast connection/disconnection through connectors of the
system itself.

1.1) Description of the plant opertation

• First switch-on and plant power supply sequence

a) Verify the correct connection of the external connectors to the cabin.

b) Activate the emergency lighting by means of the selector on connector panel [S012.13].

c) Switch-on of UPS, located on PLC and Manipulator panel, for the power supply of electronic and
emergency circuits (in case of exhausted batteries, go to the switch-on of the auxiliary electric
set).

d) Restore the black-out emergency relay by means of the proper push-button.

e) Switch-on the auxiliary generator and check the electrical parameters on generator.

f) Close switch [QF06.1] (following the procedure at step 1.4) and close switch [QF07.13]: in this
condition you can power supply the lighting and pump heater circuits.

g) Power the auxiliary circuits of main generator sets, by engaging the switches [QF01.2], [QF02.2],
[QF03.2] & [QF04.2].

h) Switch the main electrical sets on and check the current and voltage electrical parameters of
generators.

i) Closing the main switches [QF01], [QF02], [QF03] and [QF04] provides the supply of 600V main
bar system.

j) Close the power supply switch of power transformer [QF07.1].

k) Open the switch [QF06.1] of auxiliary electrical set (in this phase, emergency lamps turn on).

l) Close the switch [QF07.12] (following the procedure at step 1.4) and, if previously opened, close
the switch [QF07.11]: now the emergency lamps turn off.

m) Commission the ventilation system for the air-conditioning by switches [QF011.1] and [QF011.2].

n) At last, the operator can power the utilities necessary for the working, respecting the procedures
reported in chapter 3.9.

• Plant shutdown (for transport)


Page 5 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

a) Switch-off all the utilities following the procedures reported in annexes.

b) Set the power supply switches of the main panels to OFF position.

c) Set the switches [QF07.11] of the transformer secondary circuit to OFF position (emergency
lamps turn on).

d) Set the switches [QF01], [QF2], [QF03] & [QF04] of the main generators to OFF.

e) Switch the main electric sets off.

f) Switch-off UPS keeping the push-button on PLC panel door pressed for 5 sec.

g) Insert the emergency lighting cutting switch [S012.13].

• Maintenance procedures

Being stated that maintenance operations must be executed, respecting the


made schedules, by qualified personnel; this must be provided with all the necessary
control equipment and even with those materials specified by the scheduled
maintenance.
 For all the extraordinary maintenance operations, that is all the operations
regarding failures which cannot be foreseen, an intervention procedure must be foreseen,
however authorized by a person belonging to the plant and with perfect knowledge about the
complexity of the system object of the interventions. A series of materials of possible use, for the
urgent operations in case of need, must be however provided to maintenance operator. As
regards the management and adjustment system of mechanical plant, the maintenance and the
management of faults and anomalies will be detected, and a specific intervention modality,
directly foreseen by the management program, will correspond to the relevant fault.

 For the on-field maintenance relevant to mud pumps, respect the following prescriptions:
o Pump MP1 motor A: set the fuse main switch [QS1.1] to OFF, turn the key switch SA1.1 to
MAINTENANCE, extract the key, open the maintenance contact located near the pump.
o Pump MP1 motor B: set the fuse main switch [QS1.2] to OFF, turn the key switch SA1.2 to
MAINTENANCE, extract the key, open the maintenance contact located near the pump.
o Pump MP2 motor A: set the fuse main switch [QS2.1] to OFF, turn the key switch SA2.1 to
MAINTENANCE, extract the key, open the maintenance contact located near the pump.
o Pump MP2 motor B: set the fuse main switch [QS2.2] to OFF, turn the key switch SA2.2 to
MAINTENANCE, extract the key, open the maintenance contact located near the pump.

 For the maintenance of the hydraulic power unit motors, it is necessary:

o Motor HPU 1: set the main cutting switch [QS7.1] to OFF, set the “maintenance” selector
[SA7.1] (located inside the inverter itself) to 1.
o Motor HPU 2: set the main cutting switch [QS7.2] to OFF, set the “maintenance” selector
[SA7.2] (located inside the inverter itself) to 1.
Page 6 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

1.2) DESCRIPTION OF THE CABIN AND ITS PARTS

• The electric cabin is composed by:

Outside

o A room, for the housing and the support of Transformer BT/BT, completely closed and accessible
only by removing the proper barriers.
o A room for the housing and the support of the air-conditioning machines of the container itself.
o A room for 400/230V connection sockets and auxiliary circuits, located at one end of the
container for the power supply and the control of the utilities on field.
o Rooms for sockets, located along the long sides of the container for the interconnection of the
600V main utilities and of the manipulator.

Inside

o Panels for disconnection and protection of lines from generators and power distribution
o Panels for the start-up of mud pumps M.P.
o Panels for the start-up of hydraulic power unit H.P.U. pumps.
o Panels for the start-up of mud treatment.
o Panel for the distribution of use power supply.
o Panel for manipulator control.

Every panel is provided with I/O remote interface modules for the collection of
information to manage through the central PLC S7-300 and the operator
dialogue units (Touch panels) on the front side of the board.
Every panel /column is identified by a constructive code, allowing the fast detection
of the location of the components in the electrical drawing. Vice versa, from the
component code, it is possible to identify rapidly the page or the set of pages of
the drawing. By using the code of an auxiliary wire connected to the component,
it is possible to arrive to the exact page of the drawing.

1.3) REFERENCE ELECTRIC NORMATIVES

• CEI 17-5: Low voltage equipment - Part 2: automatic switches;


• CEI 17-11: Low voltage equipment - Part 3: manoeuvre switches, disconnecting switches,
manoeuvre- disconnecting switches and fuse-combined units;
• CEI 17-13/1 (EN 60439-1): Manoeuvre protection assembled equipment for low voltage;
• CEI 20-19: Rubber-insulated wires with rated voltage not over 450/750V;
• CEI 20-20: Poly vinyl chloride - insulated wires with rated voltage not over 450/750V;
• CEI 20-21: Calculation of electric wire capacity;
• CEI 20-40: Guide to use of low voltage cables;
• CEI 23-12/1: Sockets and plugs for industrial use – Part 1: general prescriptions;
• CEI EN 60445: Individuation of clamps and equipment and terminals of designed wires and
general rules for an alphanumeric system;
• CEI EN 60529: Protection degrees of the container (IP code);
• CEI 64-8: Utility electric systems with voltage not over 1000 V A.C. and 1500V D.C.;
Page 7 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

1.4) SAFETY RULES ADOPTED


• N° 2 Pulsanti di Black-Out, posizionati esternamen te al container in prossimità degli accessi; se azionati
tolgono tensione e spengono tutti i generatori.

• Nr 1 Black-Out push-button, located in Dog House; if operates, it disconnects the voltage and switch all
the generators off.

• Nr 1 Black-Out push-button, located in Cabin on PLC board 47000170; if operates, it disconnects the
voltage and switch all the generators off.
Page 8 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

• Electric and mechanical interlock between 400V power supply switch from auxiliary generator [QF06.1]
and 400V power supply switch from transformer [QF07.12]. This kind of operation must be executed only
by trained personnel following the reported procedure.

Power supply from Auxiliary set.


If the switch under transformer is
closed, open it by front command
(emergency lights turn-on).
This operation disengages the
mechanical interlock allowing the
closing, by local or remote command,
of the switch of the auxiliary generator
(emergency lights turn-off).

Power supply from transformer.


If the auxiliary generator switch is
closed, open it by front command
(emergency lights turn-on).
Auxiliary This operation disengages the
Transformator mechanical interlock allowing the
Generator
Switch closing, by local command, of the
Switch transformer switch (emergency lights
QF07.12
QF06.1 turn-off).

• Stop and safety circuits of Mud Pumps belong to category SIL 2; PLC boards of type FAIL-SAFE have
been used.

• Protection against direct contacts by barriers and cases. If it was necessary to access to the active parts
removing barriers, opening cases or removing parts of cases, this is possible only by using a key or a
tool. Instead, where the opening is realized by means of a push-button handle, the minimum protection
degree IP20 has been preserved, in such a way to ensure the insulation of the active parts. With the term
“key” we mean a single item or a limited number of items, and the possibility to execute this type of
operations must be entrusted only to trained personnel.
Page 9 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

• An alarm siren [HA82.1] is present in Dog House.

• Every inverter contains key disconnection switches which deactivate the emergency contactor integrated
in the inverter itself, in order to provide to maintenance ([SA1.1] [SA1.2] [SA2.1] [SA2.2] [SA7.1] [SA7.2]).

• An emergency contactor is associated to every inverter HPU. The contactor is controlled by a FAIL-SAFE
output and, if operated, stops the inverter itself.
Page 10 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

• Since the used main 600V electric system is of type IT, a proper instrument has been adopted to control
the measure of the insulation value of the plant from ground. Under the threshold values, which can be
configured by the operator, the lost of insulation is signalled. Then the PERSON RESPONSIBLE OF THE
SYSTEM IS CHARGED to manage the stop condition, in order to detect the failure point and to restore
the system status.
Clearly, in case of second ground fault, the STOP CONDITION due to the intervention of the protection
measures will be UNAVOIDABLE!
Page 11 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Chapter 2 Design tecnica data


2.1) REFERENCE ELECTRIC DATA
• Power supply:

o N° 4 Generators 1500kVA 600V 50Hz


o N° 1 Auxiliary generator 250kVA 400V 50Hz

• Transformer data:

o N° 1 Three-phase dry transformer insulation and na tural cooling:

− Power: 1000kVA
− Primary voltage: 600V
− Secondary voltage empty/load: 479,7V/460V
− Connection: triangle/star+neutral
− Group: Dyn11
− Frequency: 60Hz
− Test of voltage: 3kV

o N° 1 Three-phase dry transformer insulation and na tural cooling:

− Power: 250kVA
− Primary voltage: 460V
− Secondary voltage empty/load: 420,1V/400V
− Connection: triangle/star+neutral
− Group: Dyn11
− Frequency:60Hz
− Test of voltage: 3kV

o N° 1 Three-phase dry transformer insulation and na tural cooling:

− Power: 75kVA
− Primary voltage 460V
− Secondary voltage empty/load: 215,8V/208V
− Connection: triangle/star+neutral
− Gruppo: Dyn11
− Frequenza:60Hz
− Test of voltage: 3kV

2.2) DESIGN ELECTRO-TECHNICAL CALCULATIONS

2.2.a) Calculation of presumed Icc downstream the Generators

 Transformer 1500kVA

In = Sn / (1.73 x Un) = 1445A


Xd” = 12.4 (Vedi allegato 10.1)
Icc = (100 x In) / Xd” = 13,76kA

The demolition off the Icc due to the impedance of the cable negligible, so is not
considered.
Page 12 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

 Transformer 250kVA

In = Sn / (1.73 x Un) = 361A


Xd” = 7.2 (Presunta)
Icc = (100 x In) / Xd” = 5,01 kA

2.2.b) Calculation of presumed Icc downstream the Generators

 Transformer 1000kVA

Ucc% = 4,5%
Icc = (100 x Sn) / (1.73 x Un x Ucc%) = 3,6kA

The lowering of Icc due to cable impedance is minor, and then it is not considered.

 Transformer 250kVA

Ucc% = 4,5%
Icc = (100 x Sn) / (1.73 x Un x Ucc%) = 1,4kA

The lowering of Icc due to cable impedance is minor, and then it is not considered.

 Transformer 75kVA

Ucc% = 4,5%
Icc = (100 x Sn) / (1.73 x Un x Ucc%) = 540A

The lowering of Icc due to cable impedance is minor, and then it is not considered.

2.2.c) Calculation of presumed Icc on Bars

 Bars 600V

Icc = 13,76 x 4 = 55,04 kA


For the sizing of bar supports and switches, Ipk equal to 155kA is considered.

Icc contribution due to great-size motors is not considered, because the inverters do not
allow the return of the current from the Motor (not regenerative)

 Bars 460V (3F)

Icc = max (3,6 ; 1,4) = 3,6 kA

For the sizing of bar supports and switches, Ipk equal to 80kA is considered.
Page 13 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

2.2.d) Raceway data

 Line from Electric set 1

Type INSULATED BUS BARS


Phase section 63x1x10
Laying in air K = 1
Rated capacity In = 1600A (∆∆t = 50°)
Steady state capacity Iz = In x K = 1600A

 Line from Electric set 2

Type INSULATED BUS BARS


Phase section 63x1x10
Laying in air K = 1
Rated capacity In = 1600A (∆∆t = 50°)
Steady state capacity Iz = In x K = 1600°

 Line from Electric set 3

Type INSULATED BUS BARS


Phase section 63x1x10
Laying in air K = 1
Rated capacity In = 1600A (∆∆t = 50°)
Steady state capacity Iz = In x K = 1600A

 Line from Electric set 4

Type INSULATED BUS BARS


Phase section 63x1x10
Laying in air K = 1
Rated capacity In = 1600A (∆∆t = 50°)
Steady state capacity Iz = In x K = 1600A

 Power supply line of transformer 1000KVA

Type NSSHOU HEAVY DUTY


Phase section 3x240 (n x S)
Laying in structure hollow ref.21 K = 0,7
Single cord rated capacity In = 775A
Steady state capacity Iz = In x n x K = 1627,5A
Voltage loss % DV = 0,09%
Dissipated power = 776,98W
Working temperature = 66,07°C

 Output line of transformer 1000KVA

Type NSSHOU HEAVY DUTY


Phase section 4x240 (n x S)
Laying in structure hollow ref.21 K = 0,65
Single cord rated capacity In = 775A
Steady state capacity Iz = In x n x K = 2015A
Voltage loss % DV = 0,09%
Dissipated power = 1482,61W
Working temperature = 75,08°C
Page 14 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

 Power supply line of transformer 250KVA

Type NSSHOU HEAVY DUTY


Phase section 3x240 (n x S)
Laying in structure hollow ref.21 K = 0,7
Single cord rated capacity In = 775A
Steady state capacity Iz = In x n x K = 1627,5A
Voltage loss % DV = 0,12%
Dissipated power = 260,49W
Working temperature = 49,18°C

 Output line of transformer 250KVA

Type NSSHOU HEAVY DUTY


Phase section 4x240 (n x S)
Laying in structure hollow ref.21 K = 0,65
Single cord rated capacity In = 775A
Steady state capacity Iz = In x n x K = 2015A
Voltage loss % DV = 0,13%
Dissipated power = 455,14W
Working temperature = 61,14°C

 Power supply line of transformer 75KVA

Type NSSHOU HEAVY DUTY


Phase section 3x240 (n x S)
Laying in structure hollow ref.21 K = 0,7
Single cord rated capacity In = 775A
Steady state capacity Iz = In x n x K = 1627,5A
Voltage loss % DV = 0,14%
Dissipated power = 55,2W
Working temperature = 37,64°C

 Output line of transformer 75KVA

Type NSSHOU HEAVY DUTY


Phase section 4x240 (n x S)
Laying in structure hollow ref.21 K = 0,65
Single cord rated capacity In = 775A
Steady state capacity Iz = In x n x K = 2015A
Caduta di tensione % DV = 0,24%
Dissipated power = 408,65W
Working temperature = 67,16°C

 Power supply line AC DRIVE mud pump MP1A operation

Type OLFLEX FD90 CY


Phase section for one power supply module 2x150 (n x S)
Laying in structure hollow ref.25 K = 0,85
Single cord rated capacity In = 391A
Steady state capacity Iz = In x n x K = 665A
Voltage loss % DV = 0,05%
Dissipated power = 363,84W
Working temperature = 66,23°C
Page 15 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

 Power supply line AC DRIVE mud pump MP1B operation

Type OLFLEX FD90 CY


Phase section for one power supply module 2x150 (n x S)
Laying in structure hollow ref. 25 K = 0,85
Single cord rated capacity In = 391A
Steady state capacity Iz = In x n x K = 665A
Voltage loss % DV = 0,05%
Dissipated power = 363,84W
Working temperature = 66,23°C

 Power supply line AC DRIVE mud pump MP2A operation

Type OLFLEX FD90 CY


Phase section for one power supply module 2x150 (n x S)
Laying in structure hollow ref. 25 K = 0,85
Single cord rated capacity In = 391A
Steady state capacity Iz = In x n x K = 665A
Voltage loss % DV = 0,05%
Dissipated power = 363,84W
Working temperature = 66,23°C

 Power supply line AC DRIVE mud pump MP2B operation

Type OLFLEX FD90 CY


Phase section for one power supply module 2x150 (n x S)
Laying in structure hollow ref. 25 K = 0,85
Single cord rated capacity In = 391A
Steady state capacity Iz = In x n x K = 665A
Voltage loss % DV = 0,05%
Dissipated power = 363,84W
Working temperature = 66,23°C

 Power supply line of AIR-CONDITIONER 1

Type NSSHOU
Phase section 1x16 (n x S)
Laying in structure hollow ref. 21 K = 1
Rated capacity In = 80A
Steady state capacity Iz = In x K = 80A

 Power supply line of AIR-CONDITIONER 2

Type NSSHOU
Phase section 1x16 (n x S)
Laying in structure hollow ref. 21 K = 1
Rated capacity In = 80A
Steady state capacity Iz = In x K = 80A
Page 16 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Chapter 3 Detail description of cabin panels


3.1) PLC PANEL COMPOSED BY:

3.1.a) Panel – 47017038 - PLC

 CPU of PLC (node Profibus 2)


 Interface module for Profibus DP communication
 24Vdc auxiliary power supply
 Automatic switches of 24Vdc auxiliary circuits
 Automatic switches of 230Vca auxiliary circuits
 UPS for 230V power supply of release circuits

3.2) POWER DISTRIBUTION PANEL COMPOSED BY:

3.2.a) Column - 470170570 – generator 1 inlet, trasformer power supplì auxiliary


generator inlet and trasformer output

 Nr.1 automatic switch of type E2B-1600A in motorized with drawable execution with
horizontal rear terminals, release switch based on microprocessor with overload
protection, instantaneous short-circuit and delayed time, failure to ground. The switch is
provided with interface for Profibus DP communication and voltage measure module.
 Measure instruments for the control of voltage and current.
 N°1 Card run the parallel and synchronization of g enerator 1.
 N°2 automatic switch of type E2B-1000A in fixed ex ecution with horizontal rear terminals,
release switch based on microprocessor with overload protection, instantaneous short-
circuit and delayed time.
 N°1 Card excitation alternator generator 1.
 Ground fault monitoring tool.
 Relays contactors.
 N°1 touch-screen 15” operator panel.
 Management PLC area.
 Signalling lamps.

3.2.b) Column - 47017021- arrival generator 2 controls the generator 2, fused power
inverter fuse disconnector MP1A MP1B

 N°.1 automatic switch of type E2B-1600A in motoriz ed withdrawable execution with


horizontal rear terminals, release switch based on microprocessor with overload
protection, instantaneous short-circuit and delayed time, failure to ground. The switch is
provided with interface for Profibus DP communication and voltage measure module.
 Measure instruments for the control of voltage and current.
 N°1 Card run the parallel and synchronization of g enerator 2.
 N°2 cutting switches of type OT-1000A in fixed exe cution with front operated.
 N°1 Card excitation alternator generator 2.
 Relays and 24V contactors.
 Management PLC area.
 Signalling lamps.
Page 17 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

3.2.c) Column - 47017022 - arrival generator 3 controls the generator 3, fused power
inverter fuse disconnector MP2A MP2B

 N°.1 automatic switch of type E2B-1600A in motoriz ed with drawable execution with
horizontal rear terminals, release switch based on microprocessor with overload
protection, instantaneous short-circuit and delayed time, failure to ground. The switch is
provided with interface for Profibus DP communication and voltage measure module.
 Measure instruments for the control of voltage and current.
 N°.2 cutting switches of type OT-1600A in fixed ex ecution with horizontal rear terminals.
 Relays and 24V contactors.
 N°1 Card run the parallel and synchronization of g enerator 3.
 N°1 Card excitation alternator generator 3.
 Management PLC area.
 N°1 touch-screen 15” operator panel.
 Signalling lamps.

3.2.d) Column - 47017023 - arrival generator 4, controls generator 4, switch


upstream transformer 1000kVA, switch downstream trasformer 1000kVA
 N°.1 automatic switch of type E2B-1600A in motoriz ed with drawable execution with
horizontal rear terminals, release switch based on microprocessor with overload
protection, instantaneous short-circuit and delayed time, failure to ground. The switch is
provided with interface for Profibus DP communication and voltage measure module.
 Measure instruments for the control of voltage and current.
 N°2 automatic switch of type E2B-1000A in fixed ex ecution with horizontal rear terminals,
release switch based on microprocessor with overload protection, instantaneous short-
circuit and delayed time.
 N°1 automatic switch of type T7S-1250A in fixed ex ecution with front terminals, thermo-
magnetic release switch.
 Relays and 24V contactors.
 N°1 Card run the parallel and synchronization of g enerator 4.
 N°1 Card excitation alternator generator 4.
 Management PLC area.
 Signalling lamps.

3.2.e) Column - 47017024 - arrival generator auxiliary, switch upstream transformer


250kVA, switch downstream trasformer 250kVA

 N°2 automatic switch of type T5N-400 in fixed exec ution with front terminals, thermo-
magnetic release switch.
 Nr.1 automatic switch of type T5S-630 open in fixed motorized execution with horizontal
rear terminals, release switch based on microprocessor with overload protection,
instantaneous short-circuit and delayed time, from failure to ground.
 N°1 automatic switch of type T5S-400 in fixed exec ution with front terminals, thermo-
magnetic release switch.
 Measure instruments for the control of voltage and current.
 Relays and 24V contactors.
 Management PLC area.
 Signalling lamps.
Page 18 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

3.3) SOCKET AND DISTRIBUTION PANELS 460V - 400/230V – 208/110 COMPOSED BY:

3.3.a) Column 47017027- Switches downstream and upstream transformer 75kVA


and soket 460 - 208/110

 Modular differential magneto-thermal switches in fixed execution.


 Relays and 24V contactors.
 N°1 automatic switch upstream trasformer 75kVA.
 N°1 automatic switch downstream trasformer 75kVA.
 Management PLC area.
 Distribution system
 Signalling lamps.
 Switch and buttons of control.

3.3.b) Column 47017026- Box socket and switches 400/230V

 Modular differential magneto-thermal switches in fixed execution.


 Relays and 24V contactors.
 Management PLC area.
 Distribution system
 Signalling lamps.
 Switch and buttons of control.

3.4) ELECTRIC BOARD SOFT-STAR DEPARTURES OF ENGINE:

3.4.a) SOFT-START board switch and motor startes 75kW – 47017025

 Modular differential magneto-thermal switches in fixed execution.


 Relays and 24V contactors.
 N°2 SOFT-START type PSTB840 -690-70 with integrate d bypass.
 Management PLC area.
 Distribution system
 Signalling lamps.
 Switch and buttons of control.

3.5) PIPE HANDLER ELECTRIC BOARD:

3.5.a) Pipe handler electric board - 47017028

 Inverter for power supply and drilling pipe translation motor control
 Manipulator management PLC
 Operator interface industrial PC
 UPS
Page 19 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

3.6) INVERTER PANEL COMPOSED BY:

3.6.a) Panel - 47500504 inverter MP1A – MP2A and 47500503 inverter MP1B - MP2B

 Managment PLC area.


 Inverter ACS800

3.7) CONFIGURATION OF CABIN CONTROL SYSTEM

The management of whole network for Profibus communication is situated in PLC board
(47017051); all the control circuits relevant to the component statuses are derived from
here, as reported in the annexed layout (Profibus layout).

DETAIL (MANUAL OPERATION / AUTOMATIC / PLC / COMMAND PANEL)

NOTE: With adjective LOCAL, we mean the place where the working machines or the utilities
are present on field.

3.7.a) GENERATORS
Each generator set is equipped with:

-PCR control panel


-LOCAL control panel (generator on board)

PCR control panel

Consists of: N°1 Touch screen (common to all genera tors)

LOCAL control panel

Consists of: N° 1 Caterpillar ADEM A3 ECM control system

You can find attached documentation regarding the module.

The Generator's start/stop operations, are done only from local control panel.

NOTE: the parallel and synchronization operations for the generator set are done exclusively with automatic
procedure without any operator intervention.

All the information regarding the generator and the respective main circuit breaker, are accessible via dedicated
pages on touch screen.
Page 20 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

STARTUP PROCEDURE

• From LOCAL control panel start the generator set turning the 4 position selector on MANUAL START
position. When the engine is running the corresponding signaling lamp turning on.
• From PCR control panel push the close command of generator circuit breaker.
• At this point when the generator set is synchronized with the 600V grid, the system enable the closure of
the circuit breaker.

Four position selector

• When the unit is started it is possible to control the electrical operating parameters through dedicated
page on touch screen in PCR. The engine parameters ( e.g. temperature, fuel level, ecc), can be
controlled on local control panel.

SHUTDOWN PROCEDURE

 From PCR control panel push the opening command of generator circuit breaker.
 After verifying that the circuit breaker is in open position go to local control panel and turn the 4 position
selector on COOLDOWN STOP position.
 When the temperature go down to set value the engine stop.

3.7.b) MUD PUMPS


Each pump is equipped with:

-Dog-House control panel

Dog-House control panel

Consists of: N°1 Touch screen


N°1 BLACK-OUT mushroom push button
N°3 MUD-PUMP SPEED regulation, rotary knob (one f or each pump)
Page 21 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

NOTE: The BLACK-OUT mushroom push button overrides all other commands. Its activation automatically TURN
OFF the entire plant and, as long as active, exclude any possibility of start up.

All the informations regarding the mud pumps (number of strokes etc...) are accessible via dedicated pages on
touch screen.

For each mud pump the start/stop operations are done by proper commands displayed on touch screen.

The speed regulation of the pump can be performed via the corresponding rotary knob or by a numeric keypad
displayed on-screen, using the appropriate command. Inserting the number of strokes via the numeric keypad. By
entering the number of strokes by the numeric keypad, the pump will reach the set speed via an acceleration
ramp.

For simplicity, the following procedure are only referred to the rotary knobs

STARTUP PROCEDURE

• Turn the speed regulation rotary knob of the mud pump that you want to start, in zero position
• Select the START function on touch screen. The system will disable the main electric motor heaters and
shall verify the proper operation of mud pump auxiliaries (blower, lubrication etc...).
If the verification is successful, mud pump main electric motor is powered.
• Then proceed by turning the mud pump speed knob, until the desired number of strokes is not reached.

NOTE: At startup, as long as the mud pump speed knob is not turned in zero position, the system will prevent the
mud pump rotation. This to prevent that the pump starts immediately with a high number of strokes.

SHUTDOWN PROCEDURE

• Turn the speed regulation rotary knob of the mud pump you want to stop, in zero position
• After verifying the shutdown of pump rotation, select the STOP function on touch screen. The system
then proceed to open the main electric motor circuit breaker, turn off the auxiliaries and turn on the main
motor heaters.

3.7.c) MAIN HYDRAULIC POWER UNIT (HPU)


The main hydraulic power unit is composed by two independent units, HPU1 and HPU2 both equipped with:

-PCR control panel


-Dog-House control panel

PCR control panel

Consists of: n°1 Two-position selector (PCR-DOG HO USE) common to both the unit
n°2 START push button (one for each unit)
n°2 STOP push button (one for each unit)
n°2 ON green signaling lamps (one for each unit)
n°2 OFF red signaling lamps (one for each unit)
n°2 THERMAL tripping yellow signaling lamps (one for each unit)
n°2 EMERGENCY STOP mushroom push button with res et system (one for each unit)

Both units can be started or stopped independently of each other, but the selection of the command location is
common to both and can only be made using the appropriate two-position selector placed in PCR, as follow:

-PCR: PCR push-button controls are enabled on both units, for start/stop operations
-DOG HOUSE: Dog-House push-button controls are enabled on both units, for start/stop operations.
Page 22 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

NOTE: Enable a command location (PCR or DOG HOUSE) automatically excludes the other, except for the
EMERGENCY STOP mushroom push button.
Change the command location while the unit is ON, implies the SHUTDOWN of the unit itself.

Dog House control panel

Consists of: N°1 Touch screen

All information relating to the units HPU1 and HPU2 are accessible via dedicated pages on touch screen.
For each unit, start/stop operations are done by proper commands displayed on touch screen.

STARTUP PRODEDURE

• From PCR push-button panel, select the command location through the two-position dedicated selector

• At this time the procedure is the same, whether it is performed from PCR or from Dog House.

• Push the START button (or select the proper START function from touch screen, if you are in Dog
House).

The system shall monitor the relevant consensus signals and, in absence of abnormalities, proceed with unit
startup.

When the unit is on, the green signaling lamps turning on.

SHUTDOWN PROCEDURE

• From PCR push-button panel, select the command post through the two-position dedicated selector.

At this time the procedure is the same, whether it is performed from PCR or from Dog House.

• Push the STOP button (or select the proper STOP function from touch screen, if you are in Dog House).

When the unit is stopped, the red signaling lamps turning on.

3.7.d) Centrifugal pump of mud transfer (DESANDER and DESILTER)

Provided with:

- Local command push-button panel.


- Control panel in PCR.

Local command push-button panel

It is composed by: Nr.1 selector/push-button MAINTENANCE


Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The local push-button panel is provided by the customer.

NOTE: The push-button/selector MAINTENANCE overrides all the other commands. Activating it automatically
switches the pump off and, until active, it excludes any possibility of start-up both LOCAL and from PCR.
Page 23 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Control panel in PCR

It is composed by: Nr.1 Touch Screen (common to all centrifugal pumps)


Nr.1 two-position selector (LOCAL-PCR)
Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The selection of the start-up/shutdown position is made only by PCR by means of the proper 2-positions selector,
in the following way:

- PCR: the commands for the start-up/ shutdown from command panel in PCR are enabled.
- LOCAL: the commands for the start-up/ shutdown from local push-button panel are enabled

NOTE: For every single pump, the enabling of a command post (LOCAL or PCR.) automatically disables the
other (excluded the selector/push-button MAINTENANCE).
The change of command place with pump ON causes the automatic shutdown of the pump itself.

Start procedure

• From the control panel in PCR, enable the command post by means of the corresponding two-position
selector.
• Now the procedure is the same both if executed from PCR or from LOCAL.
• Press push-button START (or turn the selector to START).
• With pump ON the corresponding signals will turn on.

Shutdown procedure

• From the control panel where the utility has been started, press push-button STOP (or turn the selector to
STOP)
• With pump OFF, the corresponding signals turn off.

3.7.e) Centrifugal pump (SUPERCHARGING PUMP 1 & 2, TRIP TANK PUMP 1 & 2)

Provided with:

- Local command push-button panel


- Control panel in PCR
- Control panel in Doghouse

Local command push-button panel

It is composed by: Nr.1 selector/push-button MAINTENANCE


Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The local push-button panel is provided by the customer.

NOTE: The push-button/selector MAINTENANCE overrides all the other commands. Activating it automatically
switches the pump off and, until active, it excludes any possibility of start-up both LOCAL and from PCR.
Page 24 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Control panel in PCR

It is composed by: Nr.1 Touch Screen (common to all centrifugal pumps)


Nr.1 two-position selector (LOCAL-PCR)
Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

Control panel in Dog-House

It is composed by: Nr.1 Touch Screen (common to all centrifugal pumps)

The selection of the start-up/shutdown position is made only by PCR by means of the proper 2-positions selector,
in the following way:

- PCR: the commands for the start-up/shutdown from command panel in PCR are enabled.
- LOCAL: the commands for the start-up/shutdown from local push-button panel are enabled
- DOGHOUSE: the commands for the start-up/shutdown from local push-button panel are enabled from Dog-
House

NOTE: For every single pump, the enabling of a command place (LOCAL, PCR, DOG-HOUSE.) automatically
disables the others (excluded the selector/push-button MAINTENANCE).
The change of command place with pump ON causes the automatic shutdown of the pump itself.

Start procedure

• From the control panel in PCR, enable the command post by means of the corresponding two-position
selector.
• Now the procedure is the same both if executed from PCR or from LOCAL or from DOG-HOUSE.
• Press push-button START (or turn the selector to START).
• With pump ON, the corresponding signals will turn on.

Shutdown procedure

• From the control panel where the utility has been started, press push-button STOP (or turn the selector to
STOP)
• With pump OFF, the corresponding signals turn off.

3.7.f) Mixing pump (1-2-3-scorta)

Provided with:

- Local command push-button panel


- Control panel in PCR

Local command push-button panel

It is composed by: Nr.1 selector/push-button MAINTENANCE


Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The local push-button panel is provided by the customer.


Page 25 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

NOTE: The push-button/selector MAINTENANCE overrides all the other commands. Activating it automatically
switches the pump off and, until active, it excludes any possibility of start-up both LOCAL and from PCR.

Control panel in PCR

It is composed by: Nr.1 Touch Screen (common to all centrifugal pumps)


Nr.1 two-position selector (LOCAL-PCR)
Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The selection of the start-up/shutdown position is made only by PCR by means of the proper 2-positions selector,
in the following way:

- PCR: the commands for the start-up/ shutdown from command panel in PCR are enabled.
- LOCAL: the commands for the start-up/ shutdown from local push-button panel are enabled

NOTE: For every single pump, the enabling of a command post (LOCAL or PCR.) automatically disables the
other (excluded the selector/push-button MAINTENANCE).
The change of command place with pump ON causes the automatic shutdown of the pump itself.

Start procedure

• From the control panel in PCR, enable the command post by means of the corresponding two-position
selector.
• Now the procedure is the same both if executed from PCR or from LOCAL.
• Press push-button START (or turn the selector to START).
• With pump ON, the corresponding signals will turn on.

Shutdown procedure

• From the control panel where the utility has been started, press push-button STOP (or turn the selector to
STOP)
• With pump OFF, the corresponding signals turn off.

3.7.g) Water pump (1-2-3-4)


Provided with:

- Local command push-button panel


- Control panel in PCR

Local command push-button panel

It is composed by: Nr.1 selector/push-button MAINTENANCE


Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The local push-button panel is provided by the customer.

NOTE: The push-button/selector MAINTENANCE overrides all the other commands. Activating it automatically
switches the pump off and, until active, it excludes any possibility of start-up both LOCAL and from PCR.
Page 26 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Control panel in PCR

It is composed by: Nr.1 Touch Screen (common to all centrifugal pumps)


Nr.1 two-position selector (LOCAL-PCR)
Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The selection of the start-up/shutdown position is made only by PCR by means of the proper 2-positions selector,
in the following way:

- PCR: the commands for the start-up/shutdown from command panel in PCR are enabled.
- LOCAL: the commands for the start-up/shutdown from local push-button panel are enabled

NOTE: For every single pump, the enabling of a command place (LOCAL, PC) automatically disables the others
(excluded the selector/push-button MAINTENANCE).
The change of command place with pump ON causes the automatic shutdown of the pump itself.

Start procedure

• From the control panel in PCR, enable the command post by means of the corresponding two-position
selector.
• Now the procedure is the same both if executed from PCR or from LOCAL.
• Press push-button START (or turn the selector to START).
• With pump ON, the corresponding signals will turn on.

Shutdown procedure

• From the control panel where the utility has been started, press push-button STOP (or turn the selector to
STOP)
• With pump OFF, the corresponding signals turn off.

3.7.h) Mud Degasser


Provided with:

- Local command push-button panel


- Control panel in PCR

Local command push-button panel

It is composed by: Nr.1 selector/push-button MAINTENANCE


Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The local push-button panel is provided by the customer.

NOTE: The push-button/selector MAINTENANCE overrides all the other commands. Activating it automatically
switches the pump off and, until active, it excludes any possibility of start-up both LOCAL and from PCR.
.
Page 27 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Control panel in PCR

It is composed by: Nr.1 Touch Screen (common to all centrifugal pumps)


Nr.1 two-position selector (LOCAL-PCR)
Nr.1 push-button START
Nr.1 push-button STOP
Nr.1 motor green lamp ON

The selection of the start-up/shutdown position is made only by PCR by means of the proper 2-positions selector,
in the following way:

- PCR: the commands for the start-up/shutdown from command panel in PCR are enabled.
- LOCAL: the commands for the start-up/shutdown from local push-button panel are enabled

NOTE: For every single pump, the enabling of a command place (LOCAL, PC) automatically disables the others
(excluded the selector/push-button MAINTENANCE).
The change of command place with pump ON causes the automatic shutdown of the pump itself.

Start procedure

• From the control panel in PCR, enable the command post by means of the corresponding two-position
selector.
• Now the procedure is the same both if executed from PCR or from LOCAL.
• Press push-button START (or turn the selector to START).
• With pump ON, the corresponding signals will turn on.

Shutdown procedure

• From the control panel where the utility has been started, press push-button STOP (or turn the selector to
STOP)
• With pump OFF, the corresponding signals turn off.
Page 28 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Chapter 4 Calibration
4.1) CALIBRATION OF POWER SUPPLY SWITCHES FROM MAIN GENERATORS

Following the instructions of the relevant manual, set the following values of general validity on display.
Adjustments can be made depending on the plant characteristics.

4.1.a) Setting of overload intervention


Data Theoric value Set value

Curve type t=k/i²

Threshold I1 1456A = 0,91xIn

Time t1 21s

Thermic
OFF
memory

4.1.b) Setting of delayed short-circuit intervention


Data Theoric value Set value

Enabling ON

Curve type t=k/i²

Threshold I2 7200A = 4,5xIn

Time t2 0,8s

Area selectivity OFF

Start Up
OFF
enabling

4.1.c) Setting of immediate short-circuit intervention


Data Theoric value Set value

Enabling ON

Threshold I3 12800A = 8xIn

Start Up
OFF
enabling
Page 29 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

4.1.d) Setting of intervention of differential “G” (in case of failure at ground)


Data Theoric value Set value

Enabling ON

Curve type t=k/i²

Threshold I4 480A = 0,3In

Time t4 1s

4.1.e) Setting phase current unbalance


Data Theoric value Set value

Enabling ON/OFF

4.1.f) Setting protection against overtemperature inside the relay “OT”


Data Theoric value Set value

Enabling ON/OFF

4.1.g) Setting the protection of closed circuit “MCR”


Data Theoric value Set value

Enabling ON/OFF
Page 30 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

4.2) CALIBRATION OF POWER SUPPLY SWITCHES FROM AUXILIARY GENERATOR

Following the instructions of the relevant manual, set the following values of general validity on display.
Adjustments can be made depending on the plant characteristics.

4.2.a) Setting of overload intervention


Data Theoric value Set value

Threshold I1 310A = 0,775xIn

42.2b) Setting of instantaneous short-circuit intervention


Data Theoric value Set value

Enabling ON

Threshold I3 2000A = 5xIn

4.3) CALIBRATION OF TRANSFORMER 1000KVA POWER SUPPLY SWITCHES

Following the instructions of the relevant manual, set the following values of general validity on display.
Adjustments can be made depending on the plant characteristics.

4.3.a) Setting of overload intervention


Data Theoric value Set value

Threshold I1 1250A = 1xIn

Time t1 0,2s

4.3.b)Setting of instantaneous short-circuit intervention “I”


Data Theoric value Set value

Enabling ON

Threshold I3 12500A = 10xIn


Page 31 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

4.4) CALIBRATION OF TRASFORMER 1000KVA OUTPUT SWITCHES

 Following the instructions of the relevant manual, set the following values of general validity on display.
Adjustments can be made depending on the plant characteristics.

 Auxiliary circuits.

4.4.a) Setting of overload intervention


Data Theoric value Set value

Threshold I1 630 = 1xIn

Time t1 0,2s

4.4.b)Setting of instantaneous short-circuit intervention “I”


Data Theoric value Set value

Enabling ON

Threshold I3 6300A = 10xIn

 Circuito di potenza

4.4.c)Setting of overload intervention


Data Theoric value Set value

Threshold I1 1250A = 1xIn

Time t1 0,2s

4.4.d)Setting of instantaneous short-circuit intervention “I”


Data Theoric value Set value

Enabling ON

Threshold I3 12500A = 10xIn


Page 32 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

4.5) SETTING OF INSULATION CONTROLLER

Following the instructions of the relevant manual, set the specified values on display.
Note. The specified values are calculated in order to avoid, in preventive way, the circulation of dangerous
currents towards ground at the first failure to ground.

4.5.a) Setting of resistance thresholds


Data Theoric value Set value

Threshold 1 1 Mohm

Threshold 2 200 kohm


Page 33 di 91
DESIGN Date 10/06/11
HH350B Plant Power supply System Ref. PCR-003A

Chapter 5 Special operations


5.1) GESTIONE POWER-LIMIT.

 Power Control Room is provided with an intelligent system for the management of the available power,
named Power Limit, whose task is avoiding possible plant black-outs to an overload of the generators.
Depending on the power in input (variable depending on the numbers of operating generators), a threshold is
fixed on the available power, in such a way that this is lower than the first one.
When the threshold is reached, the system automatically intervenes, limiting and, if necessary, decreasing the
number of strokes of the mud pumps.

In the different pages, displayed on the two operator panels present in PCR and on that present in Dog
House, a bar is displayed pointing out the power available in percentage on a scale from 0 to 100%

The colour of the bar changes from green to yellow and to red, as the percentage of power absorbed by
the system increases.

When the set threshold is reached (generally about 85% of available power), a message of Power Limit
operating is displayed on the screen.

Until Power Limit is operating, any attempt to increase the number of strokes of the mud pumps is
forbidden by the system. The possible increase of consumption by other utilities causes a decrease of the
number of strokes of the mud pumps themselves.

When the absorbed power returns under the set threshold, the normal plant operation is restored.
Pagina 34 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Chapter 6 Anomalies

6.1) LIST OF THE ANOMALY CODES AND RELEVANT POSSIBLE CAUSES

Address Tag Name Description

Insulation
DB252,X0.0 ALARM_HMI.GENERAL.Insul600VTHR1 monitor 600V
treshold 1 Alarm
Insulation
DB252,X0.1 ALARM_HMI.GENERAL.Insul600VTHR2 monitor 600V
treshold 2 Alarm
Circuit breaker
DB252,X0.2 ALARM_HMI.GENERAL.CBAuxFeedingTripped auxiliary feeding
tripped Alarm
Circuit breaker
DB252,X0.3 ALARM_HMI.GENERAL.CB230ACUPSTripped 230Vac UPS
tripped Alarm
Circuit breaker
DB252,X0.4 ALARM_HMI.GENERAL.CB230ACTripped 230Vac tripped
Alarm
Circuit breaker
DB252,X0.5 ALARM_HMI.GENERAL.CB230ACCommandTripped 230Vac command
tripped Alarm
Circuit breaker
DB252,X0.6 ALARM_HMI.GENERAL.CB230ACFeedingTripped 230Vac feeding
tripped Alarm
Circuit breaker
460Vac
DB252,X0.7 ALARM_HMI.GENERAL.CB460ACTransfPrimClosed transforme
primary closed
Alarm
Circuit breaker
460Vac
DB252,X1.0 ALARM_HMI.GENERAL.CB460ACTransfPrimTripped transforme
primary tripped
Alarm
Transformer
DB252,X1.1 ALARM_HMI.GENERAL.Transf460VACThermPad 460Vac thermal
pad Alarm
Circuit breaker
460Vac transf.
DB252,X1.2 ALARM_HMI.GENERAL.CB460ACTransfSecClosed
secondary tripped
Alarm
Circuit breaker
460Vac
DB252,X1.3 ALARM_HMI.GENERAL.CB460ACTransfSecTripped
transforme
secondary closed
Pagina 35 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Alarm

Circuit breaker
400Vac
DB252,X1.4 ALARM_HMI.GENERAL.CB400ACTransfPrimClosed transforme
primary closed
Alarm
Circuit breaker
400Vac
DB252,X1.5 ALARM_HMI.GENERAL.CB400ACTransfPrimTripped transforme
primary tripped
Alarm
Transformer
DB252,X1.6 ALARM_HMI.GENERAL.Transf400VACThermPad 400Vac thermal
pad Alarm
Circuit breaker
400Vac
DB252,X1.7 ALARM_HMI.GENERAL.CB400ACTransfSecClosed transforme
secondary tripped
Alarm
Circuit breaker
400Vac
DB252,X2.0 ALARM_HMI.GENERAL.CB400ACTransfSecTripped transforme
secondary closed
Alarm
Circuit breaker
HPU Control
DB252,X2.1 ALARM_HMI.GENERAL.CBHPUControlSysteTripped
system tripped
Alarm
Emergency black
DB252,X2.2 ALARM_HMI.GENERAL.EME_BlackOut out module OK
Alarm
Node 1 - xxx -
DB252,X6.0 ALARM_HMI.PROFIBUS.Node01 No present on
BUS
Node 2 - xxx -
DB252,X6.1 ALARM_HMI.PROFIBUS.Node02 No present on
BUS
Node 3 - RIO
DB252,X6.2 ALARM_HMI.PROFIBUS.Node03
Generator 1
Node 4 - RIO
DB252,X6.3 ALARM_HMI.PROFIBUS.Node04
Generator 2
Node 5 - RIO
DB252,X6.4 ALARM_HMI.PROFIBUS.Node05
Generator 3
Node 6 - RIO
DB252,X6.5 ALARM_HMI.PROFIBUS.Node06
Generator 4
Node 7 - xxx -
DB252,X6.6 ALARM_HMI.PROFIBUS.Node07
No present on
Pagina 36 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

BUS

Node 8 - xxx -
DB252,X6.7 ALARM_HMI.PROFIBUS.Node08 No present on
BUS
Node 9 - RIO
DB252,X7.0 ALARM_HMI.PROFIBUS.Node09 Generator
Auxiliary
Node 10 - xxx -
DB252,X7.1 ALARM_HMI.PROFIBUS.Node10 No present on
BUS
Node 11 - xxx -
DB252,X7.2 ALARM_HMI.PROFIBUS.Node11 No present on
BUS
Node 12 - RIO
DB252,X7.3 ALARM_HMI.PROFIBUS.Node12
MP1
Node 13 - xxx -
DB252,X7.4 ALARM_HMI.PROFIBUS.Node13 No present on
BUS
Node 14 - xxx -
DB252,X7.5 ALARM_HMI.PROFIBUS.Node14 No present on
BUS
Node 15 - RIO
DB252,X7.6 ALARM_HMI.PROFIBUS.Node15
MP2
Node 16 - xxx - No
DB252,X7.7 ALARM_HMI.PROFIBUS.Node16
present on BUS
Node 17 - xxx - No
DB252,X8.0 ALARM_HMI.PROFIBUS.Node17
present on BUS
Node 18 - xxx - No
DB252,X8.1 ALARM_HMI.PROFIBUS.Node18
present on BUS
Node 19 - xxx - No
DB252,X8.2 ALARM_HMI.PROFIBUS.Node19
present on BUS
Node 20 - xxx - No
DB252,X8.3 ALARM_HMI.PROFIBUS.Node20
present on BUS
Node 21 - xxx - No
DB252,X8.4 ALARM_HMI.PROFIBUS.Node21
present on BUS
Node 22 - xxx - No
DB252,X8.5 ALARM_HMI.PROFIBUS.Node22
present on BUS
Node 23 - xxx - No
DB252,X8.6 ALARM_HMI.PROFIBUS.Node23
present on BUS
Node 24 - xxx - No
DB252,X8.7 ALARM_HMI.PROFIBUS.Node24
present on BUS
Node 25 - xxx - No
DB252,X9.0 ALARM_HMI.PROFIBUS.Node25
present on BUS
Node 26 - xxx - No
DB252,X9.1 ALARM_HMI.PROFIBUS.Node26
present on BUS
Pagina 37 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Node 27 - xxx - No
DB252,X9.2 ALARM_HMI.PROFIBUS.Node27
present on BUS
Node 28 - xxx - No
DB252,X9.3 ALARM_HMI.PROFIBUS.Node28
present on BUS
Node 29 - xxx - No
DB252,X9.4 ALARM_HMI.PROFIBUS.Node29
present on BUS
Node 30 - xxx - No
DB252,X9.5 ALARM_HMI.PROFIBUS.Node30
present on BUS
Node 31 - xxx - No
DB252,X9.6 ALARM_HMI.PROFIBUS.Node31
present on BUS
Node 32 - xxx - No
DB252,X9.7 ALARM_HMI.PROFIBUS.Node32
present on BUS
Node 33 - xxx - No
DB252,X10.0 ALARM_HMI.PROFIBUS.Node33
present on BUS
Node 34 - xxx - No
DB252,X10.1 ALARM_HMI.PROFIBUS.Node34
present on BUS
Node 35 - xxx - No
DB252,X10.2 ALARM_HMI.PROFIBUS.Node35
present on BUS
Node 36 - xxx - No
DB252,X10.3 ALARM_HMI.PROFIBUS.Node36
present on BUS
Node 37 - xxx - No
DB252,X10.4 ALARM_HMI.PROFIBUS.Node37
present on BUS
Node 38 - xxx - No
DB252,X10.5 ALARM_HMI.PROFIBUS.Node38
present on BUS
Node 39 - xxx - No
DB252,X10.6 ALARM_HMI.PROFIBUS.Node39
present on BUS
Node 40 - xxx - No
DB252,X10.7 ALARM_HMI.PROFIBUS.Node40
present on BUS
Node 41 - xxx - No
DB252,X11.0 ALARM_HMI.PROFIBUS.Node41
present on BUS
Node 42 - xxx - No
DB252,X11.1 ALARM_HMI.PROFIBUS.Node42
present on BUS
Node 43 - xxx - No
DB252,X11.2 ALARM_HMI.PROFIBUS.Node43
present on BUS
Node 44 - xxx - No
DB252,X11.3 ALARM_HMI.PROFIBUS.Node44
present on BUS
Node 45 - xxx - No
DB252,X11.4 ALARM_HMI.PROFIBUS.Node45
present on BUS
Node 46 - xxx - No
DB252,X11.5 ALARM_HMI.PROFIBUS.Node46
present on BUS
Node 47 - xxx - No
DB252,X11.6 ALARM_HMI.PROFIBUS.Node47
present on BUS
Node 48 - xxx - No
DB252,X11.7 ALARM_HMI.PROFIBUS.Node48
present on BUS
Pagina 38 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Node 49 - xxx - No
DB252,X12.0 ALARM_HMI.PROFIBUS.Node49
present on BUS
Node 50 - xxx - No
DB252,X12.1 ALARM_HMI.PROFIBUS.Node50
present on BUS
Node 51 - RIO
DB252,X12.2 ALARM_HMI.PROFIBUS.Node51
MCC.1
Node 52 - RIO
DB252,X12.3 ALARM_HMI.PROFIBUS.Node52
MCC.2
Node 53 - RIO
DB252,X12.4 ALARM_HMI.PROFIBUS.Node53
MCC.3
Node 54 - xxx -
DB252,X12.5 ALARM_HMI.PROFIBUS.Node54 No present on
BUS
Node 55 - xxx -
DB252,X12.6 ALARM_HMI.PROFIBUS.Node55 No present on
BUS
Node 56 - xxx -
DB252,X12.7 ALARM_HMI.PROFIBUS.Node56 No present on
BUS
Node 57 - xxx -
DB252,X13.0 ALARM_HMI.PROFIBUS.Node57 No present on
BUS
Node 58 - xxx -
DB252,X13.1 ALARM_HMI.PROFIBUS.Node58 No present on
BUS
Node 59 - xxx -
DB252,X13.2 ALARM_HMI.PROFIBUS.Node59 No present on
BUS
Node 60 - xxx -
DB252,X13.3 ALARM_HMI.PROFIBUS.Node60 No present on
BUS
Node 61 - xxx -
DB252,X13.4 ALARM_HMI.PROFIBUS.Node61 No present on
BUS
Node 62 - xxx -
DB252,X13.5 ALARM_HMI.PROFIBUS.Node62 No present on
BUS
Node 63 -
DB252,X13.6 ALARM_HMI.PROFIBUS.Node63 Generator 1
Circuit Breaker
Node 64 -
DB252,X13.7 ALARM_HMI.PROFIBUS.Node64 Generator 2
Circuit Breaker
Node 65 -
DB252,X14.0 ALARM_HMI.PROFIBUS.Node65 Generator 3
Circuit Breaker
Node 66 -
DB252,X14.1 ALARM_HMI.PROFIBUS.Node66
Generator 4
Pagina 39 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Circuit Breaker

Node 67 - xxx -
DB252,X14.2 ALARM_HMI.PROFIBUS.Node67 No present on
BUS
Node 68 - xxx -
DB252,X14.3 ALARM_HMI.PROFIBUS.Node68 No present on
BUS
Node 69 - xxx -
DB252,X14.4 ALARM_HMI.PROFIBUS.Node69 No present on
BUS
Node 70 - xxx -
DB252,X14.5 ALARM_HMI.PROFIBUS.Node70 No present on
BUS
Node 71 - xxx -
DB252,X14.6 ALARM_HMI.PROFIBUS.Node71 No present on
BUS
Node 72 - MP1
DB252,X14.7 ALARM_HMI.PROFIBUS.Node72
Inverter A
Node 73 - MP1
DB252,X15.0 ALARM_HMI.PROFIBUS.Node73
Inverter B
Node 74 - xxx -
DB252,X15.1 ALARM_HMI.PROFIBUS.Node74 No present on
BUS
Node 75 - MP2
DB252,X15.2 ALARM_HMI.PROFIBUS.Node75
Inverter A
Node 76 - MP2
DB252,X15.3 ALARM_HMI.PROFIBUS.Node76
Inverter B
Node 77 - xxx -
DB252,X15.4 ALARM_HMI.PROFIBUS.Node77 No present on
BUS
Node 78 - xxx -
DB252,X15.5 ALARM_HMI.PROFIBUS.Node78 No present on
BUS
Node 79 - xxx -
DB252,X15.6 ALARM_HMI.PROFIBUS.Node79 No present on
BUS
Node 80 - xxx -
DB252,X15.7 ALARM_HMI.PROFIBUS.Node80 No present on
BUS
Node 81 - HPU1
DB252,X16.0 ALARM_HMI.PROFIBUS.Node81
Softstart
Node 82 - xxx -
DB252,X16.1 ALARM_HMI.PROFIBUS.Node82 No present on
BUS
Node 83 - xxx -
DB252,X16.2 ALARM_HMI.PROFIBUS.Node83 No present on
BUS
Pagina 40 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Node 84 - HPU1
DB252,X16.3 ALARM_HMI.PROFIBUS.Node84
Softstart
Node 85 - xxx -
DB252,X16.4 ALARM_HMI.PROFIBUS.Node85 No present on
BUS
Node 86 - xxx -
DB252,X16.5 ALARM_HMI.PROFIBUS.Node86 No present on
BUS
Node 87 - xxx -
DB252,X16.6 ALARM_HMI.PROFIBUS.Node87 No present on
BUS
Node 88 - xxx -
DB252,X16.7 ALARM_HMI.PROFIBUS.Node88 No present on
BUS
Node 89 - xxx -
DB252,X17.0 ALARM_HMI.PROFIBUS.Node89 No present on
BUS
Node 90 - xxx -
DB252,X17.1 ALARM_HMI.PROFIBUS.Node90 No present on
BUS
Node 91 - xxx -
DB252,X17.2 ALARM_HMI.PROFIBUS.Node91 No present on
BUS
Node 92 - xxx -
DB252,X17.3 ALARM_HMI.PROFIBUS.Node92 No present on
BUS
Node 93 - xxx -
DB252,X17.4 ALARM_HMI.PROFIBUS.Node93 No present on
BUS
Node 94 - xxx -
DB252,X17.5 ALARM_HMI.PROFIBUS.Node94 No present on
BUS
Node 95 - xxx -
DB252,X17.6 ALARM_HMI.PROFIBUS.Node95 No present on
BUS
Node 96 - xxx -
DB252,X17.7 ALARM_HMI.PROFIBUS.Node96 No present on
BUS
Node 97 - xxx -
DB252,X18.0 ALARM_HMI.PROFIBUS.Node97 No present on
BUS
Node 98 - xxx -
DB252,X18.1 ALARM_HMI.PROFIBUS.Node98 No present on
BUS
Node 99 - xxx -
DB252,X18.2 ALARM_HMI.PROFIBUS.Node99 No present on
BUS
Node 100 - xxx -
DB252,X18.3 ALARM_HMI.PROFIBUS.Node100
No present on
Pagina 41 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

BUS

Node 101 - xxx -


DB252,X18.4 ALARM_HMI.PROFIBUS.Node101 No present on
BUS
Node 102 - xxx -
DB252,X18.5 ALARM_HMI.PROFIBUS.Node102 No present on
BUS
Node 103 - xxx -
DB252,X18.6 ALARM_HMI.PROFIBUS.Node103 No present on
BUS
Node 104 - xxx -
DB252,X18.7 ALARM_HMI.PROFIBUS.Node104 No present on
BUS
Node 105 - xxx -
DB252,X19.0 ALARM_HMI.PROFIBUS.Node105 No present on
BUS
Node 106 - xxx -
DB252,X19.1 ALARM_HMI.PROFIBUS.Node106 No present on
BUS
Node 107 - xxx -
DB252,X19.2 ALARM_HMI.PROFIBUS.Node107 No present on
BUS
Node 108 - xxx -
DB252,X19.3 ALARM_HMI.PROFIBUS.Node108 No present on
BUS
Node 109 - xxx -
DB252,X19.4 ALARM_HMI.PROFIBUS.Node109 No present on
BUS
Node 110 - xxx -
DB252,X19.5 ALARM_HMI.PROFIBUS.Node110 No present on
BUS
Node 111 - xxx -
DB252,X19.6 ALARM_HMI.PROFIBUS.Node111 No present on
BUS
Node 112 - xxx -
DB252,X19.7 ALARM_HMI.PROFIBUS.Node112 No present on
BUS
Node 113 - xxx -
DB252,X20.0 ALARM_HMI.PROFIBUS.Node113 No present on
BUS
Node 114 - xxx -
DB252,X20.1 ALARM_HMI.PROFIBUS.Node114 No present on
BUS
Node 115 - xxx -
DB252,X20.2 ALARM_HMI.PROFIBUS.Node115 No present on
BUS
Node 116 - xxx -
DB252,X20.3 ALARM_HMI.PROFIBUS.Node116
No present on
Pagina 42 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

BUS

Node 117 - xxx -


DB252,X20.4 ALARM_HMI.PROFIBUS.Node117 No present on
BUS
Node 118 - xxx -
DB252,X20.5 ALARM_HMI.PROFIBUS.Node118 No present on
BUS
Node 119 - xxx -
DB252,X20.6 ALARM_HMI.PROFIBUS.Node119 No present on
BUS
Node 120 - xxx -
DB252,X20.7 ALARM_HMI.PROFIBUS.Node120 No present on
BUS
Node 121 - xxx -
DB252,X21.0 ALARM_HMI.PROFIBUS.Node121 No present on
BUS
Node 122 - xxx -
DB252,X21.1 ALARM_HMI.PROFIBUS.Node122 No present on
BUS
Node 123 - xxx -
DB252,X21.2 ALARM_HMI.PROFIBUS.Node123 No present on
BUS
Node 124 - xxx -
DB252,X21.3 ALARM_HMI.PROFIBUS.Node124 No present on
BUS
Node 125 - xxx -
DB252,X21.4 ALARM_HMI.PROFIBUS.Node125 No present on
BUS
Node 126 - xxx -
DB252,X21.5 ALARM_HMI.PROFIBUS.Node126 No present on
BUS
Node 127 - xxx -
DB252,X21.6 ALARM_HMI.PROFIBUS.Node127 No present on
BUS
Node 128 - xxx -
DB252,X21.7 ALARM_HMI.PROFIBUS.Node128 No present on
BUS
Generator water
DB252,X22.0 ALARM_HMI.GENERATOR1.POWER.CAT_H2O_HiTemp high temperature
Alarm
Generator Oil
DB252,X22.1 ALARM_HMI.GENERATOR1.POWER.CAT_Oil_HiTemp high temperature
Alarm
Generator filter
DB252,X22.2 ALARM_HMI.GENERATOR1.POWER.CAT_FilterClogged
clogged Alarm

DB252,X22.3 ALARM_HMI.GENERATOR1.POWER.Spare02
Pagina 43 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

DB252,X22.4 ALARM_HMI.GENERATOR1.POWER.Spare03

DB252,X22.5 ALARM_HMI.GENERATOR1.POWER.Spare04

DB252,X22.6 ALARM_HMI.GENERATOR1.POWER.Spare05

Circuit breaker
auxiliary feeding
DB252,X22.7 ALARM_HMI.GENERATOR1.POWER.CAT_CB24VccClosed
24Vcc Closed
Alarm
Load High limit
DB252,X23.0 ALARM_HMI.GENERATOR1.POWER.WOODWARD_LoadHighLimit
Alarm
Load low limit
DB252,X23.1 ALARM_HMI.GENERATOR1.POWER.WOODWARD_LoadLowLimit
Alarm

DB252,X23.2 ALARM_HMI.GENERATOR1.POWER.WOODWARD_Alarm Alarm

Circuit breaker IO
DB252,X23.3 ALARM_HMI.GENERATOR1.POWER.CB24VccIOClosed PLC 24Vcc Closed
Alarm
Warning Alarm
(Any Alarm /
DB252,X26.0 ALARM_HMI.GENERATOR1.CB.Warning
Timing /
Warning)

DB252,X26.1 ALARM_HMI.GENERATOR1.CB.Trip Trip Alarm

Circuit Breaker
DB252,X26.2 ALARM_HMI.GENERATOR1.CB.CBTrip
tripped Alarm
Circuit Breaker
DB252,X26.3 ALARM_HMI.GENERATOR1.CB.CBConnected
Connected Alarm
Circuit Breaker
DB252,X26.4 ALARM_HMI.GENERATOR1.CB.CBClosed
Close Alarm
Circuit Breaker
DB252,X26.5 ALARM_HMI.GENERATOR1.CB.CBOpen
Open Alarm
Circuit Breaker
DB252,X26.6 ALARM_HMI.GENERATOR1.CB.CBUndefined
Undefined Alarm
No
DB252,X26.7 ALARM_HMI.GENERATOR1.CB.LocalBusFault communication
on local Bus
Generator water
DB252,X28.0 ALARM_HMI.GENERATOR2.POWER.CAT_H2O_HiTemp high temperature
Alarm
Generator Oil
DB252,X28.1 ALARM_HMI.GENERATOR2.POWER.CAT_Oil_HiTemp high temperature
Alarm
Generator filter
DB252,X28.2 ALARM_HMI.GENERATOR2.POWER.CAT_FilterClogged
clogged Alarm
Pagina 44 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

DB252,X28.3 ALARM_HMI.GENERATOR2.POWER.Spare02

DB252,X28.4 ALARM_HMI.GENERATOR2.POWER.Spare03

DB252,X28.5 ALARM_HMI.GENERATOR2.POWER.Spare04

DB252,X28.6 ALARM_HMI.GENERATOR2.POWER.Spare05

Circuit breaker
auxiliary feeding
DB252,X28.7 ALARM_HMI.GENERATOR2.POWER.CAT_CB24VccClosed
24Vcc Closed
Alarm
Load High limit
DB252,X29.0 ALARM_HMI.GENERATOR2.POWER.WOODWARD_LoadHighLimit
Alarm
Load low limit
DB252,X29.1 ALARM_HMI.GENERATOR2.POWER.WOODWARD_LoadLowLimit
Alarm

DB252,X29.2 ALARM_HMI.GENERATOR2.POWER.WOODWARD_Alarm Alarm

Circuit breaker IO
DB252,X29.3 ALARM_HMI.GENERATOR2.POWER.CB24VccIOClosed PLC 24Vcc Closed
Alarm
Warning Alarm
(Any Alarm /
DB252,X32.0 ALARM_HMI.GENERATOR2.CB.Warning
Timing /
Warning)

DB252,X32.1 ALARM_HMI.GENERATOR2.CB.Trip Trip Alarm

Circuit Breaker
DB252,X32.2 ALARM_HMI.GENERATOR2.CB.CBTrip
tripped Alarm
Circuit Breaker
DB252,X32.3 ALARM_HMI.GENERATOR2.CB.CBConnected
Connected Alarm
Circuit Breaker
DB252,X32.4 ALARM_HMI.GENERATOR2.CB.CBClosed
Close Alarm
Circuit Breaker
DB252,X32.5 ALARM_HMI.GENERATOR2.CB.CBOpen
Open Alarm
Circuit Breaker
DB252,X32.6 ALARM_HMI.GENERATOR2.CB.CBUndefined
Undefined Alarm
No
DB252,X32.7 ALARM_HMI.GENERATOR2.CB.LocalBusFault communication
on local Bus
Generator water
DB252,X34.0 ALARM_HMI.GENERATOR3.POWER.CAT_H2O_HiTemp high temperature
Alarm
Generator Oil
DB252,X34.1 ALARM_HMI.GENERATOR3.POWER.CAT_Oil_HiTemp high temperature
Alarm
Pagina 45 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Generator filter
DB252,X34.2 ALARM_HMI.GENERATOR3.POWER.CAT_FilterClogged
clogged Alarm

DB252,X34.3 ALARM_HMI.GENERATOR3.POWER.Spare02

DB252,X34.4 ALARM_HMI.GENERATOR3.POWER.Spare03

DB252,X34.5 ALARM_HMI.GENERATOR3.POWER.Spare04

DB252,X34.6 ALARM_HMI.GENERATOR3.POWER.Spare05

Circuit breaker
auxiliary feeding
DB252,X34.7 ALARM_HMI.GENERATOR3.POWER.CAT_CB24VccClosed
24Vcc Closed
Alarm
Load High limit
DB252,X35.0 ALARM_HMI.GENERATOR3.POWER.WOODWARD_LoadHighLimit
Alarm
Load low limit
DB252,X35.1 ALARM_HMI.GENERATOR3.POWER.WOODWARD_LoadLowLimit
Alarm

DB252,X35.2 ALARM_HMI.GENERATOR3.POWER.WOODWARD_Alarm Alarm

Circuit breaker IO
DB252,X35.3 ALARM_HMI.GENERATOR3.POWER.CB24VccIOClosed PLC 24Vcc Closed
Alarm
Warning Alarm
(Any Alarm /
DB252,X38.0 ALARM_HMI.GENERATOR3.CB.Warning
Timing /
Warning)

DB252,X38.1 ALARM_HMI.GENERATOR3.CB.Trip Trip Alarm

Circuit Breaker
DB252,X38.2 ALARM_HMI.GENERATOR3.CB.CBTrip
tripped Alarm
Circuit Breaker
DB252,X38.3 ALARM_HMI.GENERATOR3.CB.CBConnected
Connected Alarm
Circuit Breaker
DB252,X38.4 ALARM_HMI.GENERATOR3.CB.CBClosed
Close Alarm
Circuit Breaker
DB252,X38.5 ALARM_HMI.GENERATOR3.CB.CBOpen
Open Alarm
Circuit Breaker
DB252,X38.6 ALARM_HMI.GENERATOR3.CB.CBUndefined
Undefined Alarm
No
DB252,X38.7 ALARM_HMI.GENERATOR3.CB.LocalBusFault communication
on local Bus
Generator water
DB252,X40.0 ALARM_HMI.GENERATOR4.POWER.CAT_H2O_HiTemp high temperature
Alarm
Pagina 46 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Generator Oil
DB252,X40.1 ALARM_HMI.GENERATOR4.POWER.CAT_Oil_HiTemp high temperature
Alarm
Generator filter
DB252,X40.2 ALARM_HMI.GENERATOR4.POWER.CAT_FilterClogged
clogged Alarm

DB252,X40.3 ALARM_HMI.GENERATOR4.POWER.Spare02

DB252,X40.4 ALARM_HMI.GENERATOR4.POWER.Spare03

DB252,X40.5 ALARM_HMI.GENERATOR4.POWER.Spare04

DB252,X40.6 ALARM_HMI.GENERATOR4.POWER.Spare05

Circuit breaker
auxiliary feeding
DB252,X40.7 ALARM_HMI.GENERATOR4.POWER.CAT_CB24VccClosed
24Vcc Closed
Alarm
Load High limit
DB252,X41.0 ALARM_HMI.GENERATOR4.POWER.WOODWARD_LoadHighLimit
Alarm
Load low limit
DB252,X41.1 ALARM_HMI.GENERATOR4.POWER.WOODWARD_LoadLowLimit
Alarm

DB252,X41.2 ALARM_HMI.GENERATOR4.POWER.WOODWARD_Alarm Alarm

Circuit breaker IO
DB252,X41.3 ALARM_HMI.GENERATOR4.POWER.CB24VccIOClosed PLC 24Vcc Closed
Alarm
Warning Alarm
(Any Alarm /
DB252,X44.0 ALARM_HMI.GENERATOR4.CB.Warning
Timing /
Warning)

DB252,X44.1 ALARM_HMI.GENERATOR4.CB.Trip Trip Alarm

Circuit Breaker
DB252,X44.2 ALARM_HMI.GENERATOR4.CB.CBTrip
tripped Alarm
Circuit Breaker
DB252,X44.3 ALARM_HMI.GENERATOR4.CB.CBConnected
Connected Alarm
Circuit Breaker
DB252,X44.4 ALARM_HMI.GENERATOR4.CB.CBClosed
Close Alarm
Circuit Breaker
DB252,X44.5 ALARM_HMI.GENERATOR4.CB.CBOpen
Open Alarm
Circuit Breaker
DB252,X44.6 ALARM_HMI.GENERATOR4.CB.CBUndefined
Undefined Alarm
No
DB252,X44.7 ALARM_HMI.GENERATOR4.CB.LocalBusFault communication
on local Bus
Pagina 47 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Generator
DB252,X46.0 ALARM_HMI.GENERATORAUX.Generator_Alarm cumulative Alarm
Alarm
Generator
DB252,X46.1 ALARM_HMI.GENERATORAUX.Generator_Block cumulative Block
Alarm
Generator motor
DB252,X46.2 ALARM_HMI.GENERATORAUX.Generator_Run
running Alarm
Generator parallel
DB252,X46.3 ALARM_HMI.GENERATORAUX.Generator_Parallel breaker closed
Alarm
Generator circuit
DB252,X46.4 ALARM_HMI.GENERATORAUX.CBClosed breaker closed
Alarm
Generator circuit
DB252,X46.5 ALARM_HMI.GENERATORAUX.CBTripped breaker tripped
Alarm
Circuit breaker IO
DB252,X46.6 ALARM_HMI.GENERATORAUX.CB24VccIOClosed PLC 24Vcc Closed
Alarm

DB252,X52.0 ALARM_HMI.MP1.A.ReadyOn Ready On Alarm

DB252,X52.1 ALARM_HMI.MP1.A.ReadyRun Ready Run Alarm

Ready reference
DB252,X52.2 ALARM_HMI.MP1.A.ReadyRef
Alarm

DB252,X52.3 ALARM_HMI.MP1.A.Inhibit Inhibit Alarm

Drive remote
DB252,X52.4 ALARM_HMI.MP1.A.Remote Alarm (Profibus
control disable)

DB252,X52.5 ALARM_HMI.MP1.A.Fault Drive Fault Alarm

DB252,X52.6 ALARM_HMI.MP1.A.Alarm Drive Alarm

Torque reference
is followed
DB252,X52.7 ALARM_HMI.MP1.A.TorqueControl
(Master/Follower)
Alarm
Mater/Follower
link (on CH2)
DB252,X53.0 ALARM_HMI.MP1.A.MFCommError
communication
error Alarm

DB252,X53.1 ALARM_HMI.MP1.A.Spare01

DB252,X53.2 ALARM_HMI.MP1.A.Spare02
Pagina 48 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

DB252,X53.3 ALARM_HMI.MP1.A.Spare03

DB252,X53.4 ALARM_HMI.MP1.A.Spare04

DB252,X53.5 ALARM_HMI.MP1.A.Spare05

DB252,X53.6 ALARM_HMI.MP1.A.Spare06

Main power
DB252,X53.7 ALARM_HMI.MP1.A.MainPowerSwitch switch closed
Alarm
Main circuit
DB252,X60.0 ALARM_HMI.MP1.A.Blower.CBClosed breaker closed
Alarm
Main circuit
DB252,X60.1 ALARM_HMI.MP1.A.Blower.CBTripped breaker tripped
Alarm
Main contactor
DB252,X60.2 ALARM_HMI.MP1.A.Blower.Running
closed Alarm

DB252,X60.3 ALARM_HMI.MP1.A.Blower.Spare01

DB252,X60.4 ALARM_HMI.MP1.A.Blower.Spare02

Air pressure
DB252,X60.5 ALARM_HMI.MP1.A.Blower.AirPS
switch Alarm

DB252,X62.0 ALARM_HMI.MP1.B.ReadyOn Ready On Alarm

DB252,X62.1 ALARM_HMI.MP1.B.ReadyRun Ready Run Alarm

Ready reference
DB252,X62.2 ALARM_HMI.MP1.B.ReadyRef
Alarm

DB252,X62.3 ALARM_HMI.MP1.B.Inhibit Inhibit Alarm

Drive remote
DB252,X62.4 ALARM_HMI.MP1.B.Remote Alarm (Profibus
control disable)

DB252,X62.5 ALARM_HMI.MP1.B.Fault Drive Fault Alarm

DB252,X62.6 ALARM_HMI.MP1.B.Alarm Drive Alarm

Torque reference
is followed
DB252,X62.7 ALARM_HMI.MP1.B.TorqueControl
(Master/Follower)
Alarm
Pagina 49 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Mater/Follower
link (on CH2)
DB252,X63.0 ALARM_HMI.MP1.B.MFCommError
communication
error Alarm

DB252,X63.1 ALARM_HMI.MP1.B.Spare01

DB252,X63.2 ALARM_HMI.MP1.B.Spare02

DB252,X63.3 ALARM_HMI.MP1.B.Spare03

DB252,X63.4 ALARM_HMI.MP1.B.Spare04

DB252,X63.5 ALARM_HMI.MP1.B.Spare05

DB252,X63.6 ALARM_HMI.MP1.B.Spare06

Main power
DB252,X63.7 ALARM_HMI.MP1.B.MainPowerSwitch switch closed
Alarm
Main circuit
DB252,X70.0 ALARM_HMI.MP1.B.Blower.CBClosed breaker closed
Alarm
Main circuit
DB252,X70.1 ALARM_HMI.MP1.B.Blower.CBTripped breaker tripped
Alarm
Main contactor
DB252,X70.2 ALARM_HMI.MP1.B.Blower.Running
closed Alarm

DB252,X70.3 ALARM_HMI.MP1.B.Blower.Spare01

DB252,X70.4 ALARM_HMI.MP1.B.Blower.Spare02

Air pressure
DB252,X70.5 ALARM_HMI.MP1.B.Blower.AirPS
switch Alarm
Main circuit
DB252,X72.0 ALARM_HMI.MP1.Heater.CBClosed breaker closed
Alarm
Main circuit
DB252,X72.1 ALARM_HMI.MP1.Heater.CBTripped breaker tripped
Alarm
Main contactor
DB252,X72.2 ALARM_HMI.MP1.Heater.Running
closed Alarm
Main circuit
DB252,X74.0 ALARM_HMI.MP1.WashPump.CBClosed breaker closed
Alarm
Main circuit
DB252,X74.1 ALARM_HMI.MP1.WashPump.CBTripped
breaker tripped
Pagina 50 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Alarm

Main contactor
DB252,X74.2 ALARM_HMI.MP1.WashPump.Running
closed Alarm
Main circuit
DB252,X76.0 ALARM_HMI.MP1.SupChargPump.CBClosed breaker closed
Alarm
Main circuit
DB252,X76.1 ALARM_HMI.MP1.SupChargPump.CBTripped breaker tripped
Alarm
Main contactor
DB252,X76.2 ALARM_HMI.MP1.SupChargPump.Running
closed Alarm
Main circuit
DB252,X78.0 ALARM_HMI.MP1.Lubrication.CBClosed breaker closed
Alarm
Main circuit
DB252,X78.1 ALARM_HMI.MP1.Lubrication.CBTripped breaker tripped
Alarm
Main contactor
DB252,X78.2 ALARM_HMI.MP1.Lubrication.Running
closed Alarm

DB252,X78.3 ALARM_HMI.MP1.Lubrication.Spare01

DB252,X78.4 ALARM_HMI.MP1.Lubrication.Spare02

Oil flow switch


DB252,X78.5 ALARM_HMI.MP1.Lubrication.OilFS
Alarm
Oil temperature
switch high
DB252,X78.6 ALARM_HMI.MP1.Lubrication.OilTS
temperature
Alarm
Oil low level
DB252,X78.7 ALARM_HMI.MP1.Lubrication.OilLLS
switch Alarm
Oil high level
DB252,X79.0 ALARM_HMI.MP1.Lubrication.OilHLS
switch Alarm
Oil level switch
DB252,X79.1 ALARM_HMI.MP1.Lubrication.OilLS incongruence
Alarm
Oil filter clogged
DB252,X79.2 ALARM_HMI.MP1.Lubrication.OilFiltKo
Alarm
Cooling flow
DB252,X80.0 ALARM_HMI.MP1.CoolingFS
switch Alarm

DB252,X82.0 ALARM_HMI.MP2.A.ReadyOn Ready On Alarm

DB252,X82.1 ALARM_HMI.MP2.A.ReadyRun Ready Run Alarm


Pagina 51 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Ready reference
DB252,X82.2 ALARM_HMI.MP2.A.ReadyRef
Alarm

DB252,X82.3 ALARM_HMI.MP2.A.Inhibit Inhibit Alarm

Drive remote
DB252,X82.4 ALARM_HMI.MP2.A.Remote Alarm (Profibus
control disable)

DB252,X82.5 ALARM_HMI.MP2.A.Fault Drive Fault Alarm

DB252,X82.6 ALARM_HMI.MP2.A.Alarm Drive Alarm

Torque reference
is followed
DB252,X82.7 ALARM_HMI.MP2.A.TorqueControl
(Master/Follower)
Alarm
Mater/Follower
link (on CH2)
DB252,X83.0 ALARM_HMI.MP2.A.MFCommError
communication
error Alarm

DB252,X83.1 ALARM_HMI.MP2.A.Spare01

DB252,X83.2 ALARM_HMI.MP2.A.Spare02

DB252,X83.3 ALARM_HMI.MP2.A.Spare03

DB252,X83.4 ALARM_HMI.MP2.A.Spare04

DB252,X83.5 ALARM_HMI.MP2.A.Spare05

DB252,X83.6 ALARM_HMI.MP2.A.Spare06

Main power
DB252,X83.7 ALARM_HMI.MP2.A.MainPowerSwitch switch closed
Alarm
Main circuit
DB252,X90.0 ALARM_HMI.MP2.A.Blower.CBClosed breaker closed
Alarm
Main circuit
DB252,X90.1 ALARM_HMI.MP2.A.Blower.CBTripped breaker tripped
Alarm
Main contactor
DB252,X90.2 ALARM_HMI.MP2.A.Blower.Running
closed Alarm

DB252,X90.3 ALARM_HMI.MP2.A.Blower.Spare01

DB252,X90.4 ALARM_HMI.MP2.A.Blower.Spare02
Pagina 52 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Air pressure
DB252,X90.5 ALARM_HMI.MP2.A.Blower.AirPS
switch Alarm

DB252,X92.0 ALARM_HMI.MP2.B.ReadyOn Ready On Alarm

DB252,X92.1 ALARM_HMI.MP2.B.ReadyRun Ready Run Alarm

Ready reference
DB252,X92.2 ALARM_HMI.MP2.B.ReadyRef
Alarm

DB252,X92.3 ALARM_HMI.MP2.B.Inhibit Inhibit Alarm

Drive remote
DB252,X92.4 ALARM_HMI.MP2.B.Remote Alarm (Profibus
control disable)

DB252,X92.5 ALARM_HMI.MP2.B.Fault Drive Fault Alarm

DB252,X92.6 ALARM_HMI.MP2.B.Alarm Drive Alarm

Torque reference
is followed
DB252,X92.7 ALARM_HMI.MP2.B.TorqueControl
(Master/Follower)
Alarm
Mater/Follower
link (on CH2)
DB252,X93.0 ALARM_HMI.MP2.B.MFCommError
communication
error Alarm

DB252,X93.1 ALARM_HMI.MP2.B.Spare01

DB252,X93.2 ALARM_HMI.MP2.B.Spare02

DB252,X93.3 ALARM_HMI.MP2.B.Spare03

DB252,X93.4 ALARM_HMI.MP2.B.Spare04

DB252,X93.5 ALARM_HMI.MP2.B.Spare05

DB252,X93.6 ALARM_HMI.MP2.B.Spare06

Main power
DB252,X93.7 ALARM_HMI.MP2.B.MainPowerSwitch switch closed
Alarm
Main circuit
DB252,X100.0 ALARM_HMI.MP2.B.Blower.CBClosed breaker closed
Alarm
Main circuit
DB252,X100.1 ALARM_HMI.MP2.B.Blower.CBTripped breaker tripped
Alarm
Pagina 53 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Main contactor
DB252,X100.2 ALARM_HMI.MP2.B.Blower.Running
closed Alarm

DB252,X100.3 ALARM_HMI.MP2.B.Blower.Spare01

DB252,X100.4 ALARM_HMI.MP2.B.Blower.Spare02

Air pressure
DB252,X100.5 ALARM_HMI.MP2.B.Blower.AirPS
switch Alarm
Main circuit
DB252,X102.0 ALARM_HMI.MP2.Heater.CBClosed breaker closed
Alarm
Main circuit
DB252,X102.1 ALARM_HMI.MP2.Heater.CBTripped breaker tripped
Alarm
Main contactor
DB252,X102.2 ALARM_HMI.MP2.Heater.Running
closed Alarm
Main circuit
DB252,X104.0 ALARM_HMI.MP2.WashPump.CBClosed breaker closed
Alarm
Main circuit
DB252,X104.1 ALARM_HMI.MP2.WashPump.CBTripped breaker tripped
Alarm
Main contactor
DB252,X104.2 ALARM_HMI.MP2.WashPump.Running
closed Alarm
Main circuit
DB252,X106.0 ALARM_HMI.MP2.SupChargPump.CBClosed breaker closed
Alarm
Main circuit
DB252,X106.1 ALARM_HMI.MP2.SupChargPump.CBTripped breaker tripped
Alarm
Main contactor
DB252,X106.2 ALARM_HMI.MP2.SupChargPump.Running
closed Alarm
Main circuit
DB252,X108.0 ALARM_HMI.MP2.Lubrication.CBClosed breaker closed
Alarm
Main circuit
DB252,X108.1 ALARM_HMI.MP2.Lubrication.CBTripped breaker tripped
Alarm
Main contactor
DB252,X108.2 ALARM_HMI.MP2.Lubrication.Running
closed Alarm

DB252,X108.3 ALARM_HMI.MP2.Lubrication.Spare01

DB252,X108.4 ALARM_HMI.MP2.Lubrication.Spare02

Oil flow switch


DB252,X108.5 ALARM_HMI.MP2.Lubrication.OilFS
Alarm
Pagina 54 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Oil temperature
switch high
DB252,X108.6 ALARM_HMI.MP2.Lubrication.OilTS
temperature
Alarm
Oil low level
DB252,X108.7 ALARM_HMI.MP2.Lubrication.OilLLS
switch Alarm
Oil high level
DB252,X109.0 ALARM_HMI.MP2.Lubrication.OilHLS
switch Alarm
Oil level switch
DB252,X109.1 ALARM_HMI.MP2.Lubrication.OilLS incongruence
Alarm
Oil filter clogged
DB252,X109.2 ALARM_HMI.MP2.Lubrication.OilFiltKo
Alarm
Cooling flow
DB252,X110.0 ALARM_HMI.MP2.CoolingFS
switch Alarm
Desander - Main
DB252,X192.0 ALARM_HMI.SHAKER_TANK.Desander_CBClosed circuit breaker
closed Alarm
Desander - Main
DB252,X192.1 ALARM_HMI.SHAKER_TANK.Desander_CBTripped circuit breaker
tripped Alarm
Desander - Main
DB252,X192.2 ALARM_HMI.SHAKER_TANK.Desander_Running contactor closed
Alarm

DB252,X192.3 ALARM_HMI.SHAKER_TANK.Desander_Spare01

DB252,X192.4 ALARM_HMI.SHAKER_TANK.Desander_Spare02

Desilter - Main
DB252,X192.5 ALARM_HMI.SHAKER_TANK.Desilter_CBClosed circuit breaker
closed Alarm
Desilter - Main
DB252,X192.6 ALARM_HMI.SHAKER_TANK.Desilter_CBTripped circuit breaker
tripped Alarm
Desilter - Main
DB252,X192.7 ALARM_HMI.SHAKER_TANK.Desilter_Running contactor closed
Alarm

DB252,X193.0 ALARM_HMI.SHAKER_TANK.Desilter_Spare01

DB252,X193.1 ALARM_HMI.SHAKER_TANK.Desilter_Spare02

Mud degasser
Pump - Main
DB252,X193.2 ALARM_HMI.SHAKER_TANK.MudDegasserPump_CBClosed
circuit breaker
closed Alarm
Mud degasser
DB252,X193.3 ALARM_HMI.SHAKER_TANK.MudDegasserPum_CBTripped
Pump - Main
Pagina 55 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

circuit breaker
tripped Alarm
Mud degasser
Pump - Main
DB252,X193.4 ALARM_HMI.SHAKER_TANK.MudDegasserPump_Running
contactor closed
Alarm

DB252,X193.5 ALARM_HMI.SHAKER_TANK.MudDegasserPump_Spare02

DB252,X193.6 ALARM_HMI.SHAKER_TANK.MudDegasserPump_Spare03

Centrifugal Pump
1 - Main circuit
DB252,X204.0 ALARM_HMI.WATER_TANK1.CentrPump1_CBClosed
breaker closed
Alarm
Centrifugal Pump
1 - Main circuit
DB252,X204.1 ALARM_HMI.WATER_TANK1.CentrPump1_CBTripped
breaker tripped
Alarm
Centrifugal Pump
1 - Main
DB252,X204.2 ALARM_HMI.WATER_TANK1.CentrPump1_Running
contactor closed
Alarm

DB252,X204.3 ALARM_HMI.WATER_TANK1.CentrPump1_Spare01

DB252,X204.4 ALARM_HMI.WATER_TANK1.CentrPump1_Spare02

Centrifugal Pump
2 - Main circuit
DB252,X204.5 ALARM_HMI.WATER_TANK1.CentrPump2_CBClosed
breaker closed
Alarm
Centrifugal Pump
2 - Main circuit
DB252,X204.6 ALARM_HMI.WATER_TANK1.CentrPump2_CBTripped
breaker tripped
Alarm
Centrifugal Pump
2 - Main
DB252,X204.7 ALARM_HMI.WATER_TANK1.CentrPump2_Running
contactor closed
Alarm

DB252,X205.0 ALARM_HMI.WATER_TANK1.CentrPump2_Spare01

DB252,X205.1 ALARM_HMI.WATER_TANK1.CentrPump2_Spare02

Centrifugal Pump
1 - Main circuit
DB252,X206.0 ALARM_HMI.WATER_TANK2.CentrPump1_CBClosed
breaker closed
Alarm
Pagina 56 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Centrifugal Pump
1 - Main circuit
DB252,X206.1 ALARM_HMI.WATER_TANK2.CentrPump1_CBTripped
breaker tripped
Alarm
Centrifugal Pump
1 - Main
DB252,X206.2 ALARM_HMI.WATER_TANK2.CentrPump1_Running
contactor closed
Alarm

DB252,X206.3 ALARM_HMI.WATER_TANK2.CentrPump1_Spare01

DB252,X206.4 ALARM_HMI.WATER_TANK2.CentrPump1_Spare02

Centrifugal Pump
2 - Main circuit
DB252,X206.5 ALARM_HMI.WATER_TANK2.CentrPump2_CBClosed
breaker closed
Alarm
Centrifugal Pump
2 - Main circuit
DB252,X206.6 ALARM_HMI.WATER_TANK2.CentrPump2_CBTripped
breaker tripped
Alarm
Centrifugal Pump
2 - Main
DB252,X206.7 ALARM_HMI.WATER_TANK2.CentrPump2_Running
contactor closed
Alarm

DB252,X207.0 ALARM_HMI.WATER_TANK2.CentrPump2_Spare01

DB252,X207.1 ALARM_HMI.WATER_TANK2.CentrPump2_Spare02

Centrifugal Pump
1 - Main circuit
DB252,X208.0 ALARM_HMI.TRIP_TANK.CentrPump1_CBClosed
breaker closed
Alarm
Centrifugal Pump
1 - Main circuit
DB252,X208.1 ALARM_HMI.TRIP_TANK.CentrPump1_CBTripped
breaker tripped
Alarm
Centrifugal Pump
1 - Main
DB252,X208.2 ALARM_HMI.TRIP_TANK.CentrPump1_Running
contactor closed
Alarm

DB252,X208.3 ALARM_HMI.TRIP_TANK.CentrPump1_Spare01

DB252,X208.4 ALARM_HMI.TRIP_TANK.CentrPump1_Spare02

Centrifugal Pump
2 - Main circuit
DB252,X208.5 ALARM_HMI.TRIP_TANK.CentrPump2_CBClosed
breaker closed
Alarm
Pagina 57 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Centrifugal Pump
2 - Main circuit
DB252,X208.6 ALARM_HMI.TRIP_TANK.CentrPump2_CBTripped
breaker tripped
Alarm
Centrifugal Pump
2 - Main
DB252,X208.7 ALARM_HMI.TRIP_TANK.CentrPump2_Running
contactor closed
Alarm

DB252,X209.0 ALARM_HMI.TRIP_TANK.CentrPump2_Spare01

DB252,X209.1 ALARM_HMI.TRIP_TANK.CentrPump2_Spare02

Centrifugal Pump
1 - Main circuit
DB252,X210.0 ALARM_HMI.MIXING_TANK.CentrPump1_CBClosed
breaker closed
Alarm
Centrifugal Pump
1 - Main circuit
DB252,X210.1 ALARM_HMI.MIXING_TANK.CentrPump1_CBTripped
breaker tripped
Alarm
Centrifugal Pump
1 - Main
DB252,X210.2 ALARM_HMI.MIXING_TANK.CentrPump1_Running
contactor closed
Alarm

DB252,X210.3 ALARM_HMI.MIXING_TANK.CentrPump1_Spare01

DB252,X210.4 ALARM_HMI.MIXING_TANK.CentrPump1_Spare02

Centrifugal Pump
2 - Main circuit
DB252,X210.5 ALARM_HMI.MIXING_TANK.CentrPump2_CBClosed
breaker closed
Alarm
Centrifugal Pump
2 - Main circuit
DB252,X210.6 ALARM_HMI.MIXING_TANK.CentrPump2_CBTripped
breaker tripped
Alarm
Centrifugal Pump
2 - Main
DB252,X210.7 ALARM_HMI.MIXING_TANK.CentrPump2_Running
contactor closed
Alarm

DB252,X211.0 ALARM_HMI.MIXING_TANK.CentrPump2_Spare01

DB252,X211.1 ALARM_HMI.MIXING_TANK.CentrPump2_Spare02

Centrifugal Pump
3 - Main circuit
DB252,X211.2 ALARM_HMI.MIXING_TANK.CentrPump3_CBClosed
breaker closed
Alarm
Pagina 58 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Centrifugal Pump
3 - Main circuit
DB252,X211.3 ALARM_HMI.MIXING_TANK.CentrPump3_CBTripped
breaker tripped
Alarm
Centrifugal Pump
3 - Main
DB252,X211.4 ALARM_HMI.MIXING_TANK.CentrPump3_Running
contactor closed
Alarm

DB252,X211.5 ALARM_HMI.MIXING_TANK.CentrPump3_Spare01

DB252,X211.6 ALARM_HMI.MIXING_TANK.CentrPump3_Spare02

Centrifugal Pump
4 - Main circuit
DB252,X211.7 ALARM_HMI.MIXING_TANK.CentrPump4_CBClosed
breaker closed
Alarm
Centrifugal Pump
4 - Main circuit
DB252,X212.0 ALARM_HMI.MIXING_TANK.CentrPump4_CBTripped
breaker tripped
Alarm
Centrifugal Pump
4 - Main
DB252,X212.1 ALARM_HMI.MIXING_TANK.CentrPump4_Running
contactor closed
Alarm

DB252,X212.2 ALARM_HMI.MIXING_TANK.CentrPump4_Spare01

DB252,X212.3 ALARM_HMI.MIXING_TANK.CentrPump4_Spare02

Spare 1 - Main
DB252,X222.0 ALARM_HMI.MCC_SERVICE.Spare1_CBClosed circuit breaker
closed Alarm
Spare 1 - Main
DB252,X222.1 ALARM_HMI.MCC_SERVICE.Spare1_CBTripped circuit breaker
tripped Alarm
Spare 1 - Main
DB252,X222.2 ALARM_HMI.MCC_SERVICE.Spare1_Running contactor closed
Alarm

DB252,X222.3 ALARM_HMI.MCC_SERVICE.Spare1_Spare01

DB252,X222.4 ALARM_HMI.MCC_SERVICE.Spare1_Spare02

Spare 2 - Main
DB252,X222.5 ALARM_HMI.MCC_SERVICE.Spare2_CBClosed circuit breaker
closed Alarm
Spare 2 - Main
DB252,X222.6 ALARM_HMI.MCC_SERVICE.Spare2_CBTripped circuit breaker
tripped Alarm
Pagina 59 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Spare 2 - Main
DB252,X222.7 ALARM_HMI.MCC_SERVICE.Spare2_Running contactor closed
Alarm

DB252,X223.0 ALARM_HMI.MCC_SERVICE.Spare2_Spare01

DB252,X223.1 ALARM_HMI.MCC_SERVICE.Spare2_Spare02

Spare 3 - Main
DB252,X223.2 ALARM_HMI.MCC_SERVICE.Spare3_CBClosed circuit breaker
closed Alarm
Spare 3 - Main
DB252,X223.3 ALARM_HMI.MCC_SERVICE.Spare3_CBTripped circuit breaker
tripped Alarm
Spare 3 - Main
DB252,X223.4 ALARM_HMI.MCC_SERVICE.Spare3_Running contactor closed
Alarm

DB252,X223.5 ALARM_HMI.MCC_SERVICE.Spare3_Spare02

DB252,X223.6 ALARM_HMI.MCC_SERVICE.Spare3_Spare03

Spare 4 - Main
DB252,X223.7 ALARM_HMI.MCC_SERVICE.Spare4_CBClosed circuit breaker
closed Alarm
Spare 4 - Main
DB252,X224.0 ALARM_HMI.MCC_SERVICE.Spare4_CBTripped circuit breaker
tripped Alarm

DB252,X224.1 ALARM_HMI.MCC_SERVICE.Spare4_Spare01

DB252,X224.2 ALARM_HMI.MCC_SERVICE.Spare4_Spare02

DB252,X224.3 ALARM_HMI.MCC_SERVICE.Spare4_Spare03

Spare 5 - Main
DB252,X224.4 ALARM_HMI.MCC_SERVICE.Spare5_CBClosed circuit breaker
closed Alarm
Spare 5 - Main
DB252,X224.5 ALARM_HMI.MCC_SERVICE.Spare5_CBTripped circuit breaker
tripped Alarm

DB252,X224.6 ALARM_HMI.MCC_SERVICE.Spare5_Spare01

DB252,X224.7 ALARM_HMI.MCC_SERVICE.Spare5_Spare02

DB252,X225.0 ALARM_HMI.MCC_SERVICE.Spare5_Spare03

Spare 6 - Main
DB252,X225.1 ALARM_HMI.MCC_SERVICE.Spare6_CBClosed circuit breaker
closed Alarm
Pagina 60 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Spare 6 - Main
DB252,X225.2 ALARM_HMI.MCC_SERVICE.Spare6_CBTripped circuit breaker
tripped Alarm

DB252,X225.3 ALARM_HMI.MCC_SERVICE.Spare6_Spare01

DB252,X225.4 ALARM_HMI.MCC_SERVICE.Spare6_Spare02

DB252,X225.5 ALARM_HMI.MCC_SERVICE.Spare6_Spare03

Spare 7 - Main
DB252,X225.6 ALARM_HMI.MCC_SERVICE.Spare7_CBClosed circuit breaker
closed Alarm
Spare 7 - Main
DB252,X225.7 ALARM_HMI.MCC_SERVICE.Spare7_CBTripped circuit breaker
tripped Alarm

DB252,X226.0 ALARM_HMI.MCC_SERVICE.Spare7_Spare01

DB252,X226.1 ALARM_HMI.MCC_SERVICE.Spare7_Spare02

DB252,X226.2 ALARM_HMI.MCC_SERVICE.Spare7_Spare03

Spare 8 - Main
DB252,X226.3 ALARM_HMI.MCC_SERVICE.Spare8_CBClosed circuit breaker
closed Alarm
Spare 8 - Main
DB252,X226.4 ALARM_HMI.MCC_SERVICE.Spare8_CBTripped circuit breaker
tripped Alarm

DB252,X226.5 ALARM_HMI.MCC_SERVICE.Spare8_Spare01

DB252,X226.6 ALARM_HMI.MCC_SERVICE.Spare8_Spare02

DB252,X226.7 ALARM_HMI.MCC_SERVICE.Spare8_Spare03

Spare 9 - Main
DB252,X227.0 ALARM_HMI.MCC_SERVICE.Spare9_CBClosed circuit breaker
closed Alarm
Spare 9 - Main
DB252,X227.1 ALARM_HMI.MCC_SERVICE.Spare9_CBTripped circuit breaker
tripped Alarm

DB252,X227.2 ALARM_HMI.MCC_SERVICE.Spare9_Spare01

DB252,X227.3 ALARM_HMI.MCC_SERVICE.Spare9_Spare02

DB252,X227.4 ALARM_HMI.MCC_SERVICE.Spare9_Spare03
Pagina 61 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Spare 10 - Main
DB252,X227.5 ALARM_HMI.MCC_SERVICE.Spare10_CBClosed circuit breaker
closed Alarm
Spare 10 - Main
DB252,X227.6 ALARM_HMI.MCC_SERVICE.Spare10_CBTripped circuit breaker
tripped Alarm

DB252,X227.7 ALARM_HMI.MCC_SERVICE.Spare10_Spare01

DB252,X228.0 ALARM_HMI.MCC_SERVICE.Spare10_Spare02

DB252,X228.1 ALARM_HMI.MCC_SERVICE.Spare10_Spare03

Spare 11 - Main
DB252,X228.2 ALARM_HMI.MCC_SERVICE.Spare11_CBClosed circuit breaker
closed Alarm
Spare 11 - Main
DB252,X228.3 ALARM_HMI.MCC_SERVICE.Spare11_CBTripped circuit breaker
tripped Alarm

DB252,X228.4 ALARM_HMI.MCC_SERVICE.Spare11_Spare01

DB252,X228.5 ALARM_HMI.MCC_SERVICE.Spare11_Spare02

DB252,X228.6 ALARM_HMI.MCC_SERVICE.Spare11_Spare03

Spare 12 - Main
DB252,X228.7 ALARM_HMI.MCC_SERVICE.Spare12_CBClosed circuit breaker
closed Alarm
Spare 12 - Main
DB252,X229.0 ALARM_HMI.MCC_SERVICE.Spare12_CBTripped circuit breaker
tripped Alarm

DB252,X229.1 ALARM_HMI.MCC_SERVICE.Spare12_Spare01

DB252,X229.2 ALARM_HMI.MCC_SERVICE.Spare12_Spare02

DB252,X229.3 ALARM_HMI.MCC_SERVICE.Spare12_Spare03

BOP Accumulator
- Main circuit
DB252,X229.4 ALARM_HMI.MCC_SERVICE.BOPAccumulator_CBClosed
breaker closed
Alarm
BOP Accumulator
- Main circuit
DB252,X229.5 ALARM_HMI.MCC_SERVICE.BOPAccumulato_CBTripped
breaker tripped
Alarm

DB252,X229.6 ALARM_HMI.MCC_SERVICE.BOPAccumulator_Spare01
Pagina 62 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Compressor 1 -
Main circuit
DB252,X229.7 ALARM_HMI.MCC_SERVICE.Compressor1_CBClosed
breaker closed
Alarm
Compressor 1 -
Main circuit
DB252,X230.0 ALARM_HMI.MCC_SERVICE.Compressor1_CBTripped
breaker tripped
Alarm

DB252,X230.1 ALARM_HMI.MCC_SERVICE.Compressor1_Spare01

Compressor 2 -
Main circuit
DB252,X230.2 ALARM_HMI.MCC_SERVICE.Compressor2_CBClosed
breaker closed
Alarm
Compressor 2 -
Main circuit
DB252,X230.3 ALARM_HMI.MCC_SERVICE.Compressor2_CBTripped
breaker tripped
Alarm

DB252,X230.4 ALARM_HMI.MCC_SERVICE.Compressor2_Spare01

Circuit breaker
auction
DB252,X232.0 ALARM_HMI.MCC_SERVICE.SpareCB.CBAuctionManipTripped
manipulator
tripped Alarm
Circuit breaker IO
DB252,X232.1 ALARM_HMI.MCC_SERVICE.SpareCB.CB24VccIOTripped PLC 24Vcc
tripped Alarm
Circuit breaker
Line 1 light and
DB252,X232.2 ALARM_HMI.MCC_SERVICE.SpareCB.CBLine1LightServTripped
service tripped
Alarm
Circuit breaker
Line 2 light and
DB252,X232.3 ALARM_HMI.MCC_SERVICE.SpareCB.CBLine2LightServTripped
service tripped
Alarm
Circuit breaker
DB252,X232.4 ALARM_HMI.MCC_SERVICE.SpareCB.CB150ASpare1Tripped 150A Spare 1
tripped Alarm
Circuit breaker
DB252,X232.5 ALARM_HMI.MCC_SERVICE.SpareCB.CB150ASpare2Tripped 150A Spare 2
tripped Alarm
Circuit breaker
DB252,X232.6 ALARM_HMI.MCC_SERVICE.SpareCB.CB63ASpare1Tripped 63A Spare 1
tripped Alarm
Circuit breaker
DB252,X232.7 ALARM_HMI.MCC_SERVICE.SpareCB.CB63ASpare2Tripped 63A Spare 2
tripped Alarm
Pagina 63 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Circuit breaker
DB252,X233.0 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare1Tripped 32A Spare 1
tripped Alarm
Circuit breaker
DB252,X233.1 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare2Tripped 32A Spare 2
tripped Alarm
Circuit breaker
DB252,X233.2 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare3Tripped 32A Spare 3
tripped Alarm
Circuit breaker
DB252,X233.3 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare4Tripped 32A Spare 4
tripped Alarm
Circuit breaker
DB252,X233.4 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare5Tripped 32A Spare 5
tripped Alarm
Circuit breaker
DB252,X233.5 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare6Tripped 32A Spare 6
tripped Alarm
Circuit breaker
DB252,X233.6 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare7Tripped 32A Spare 7
tripped Alarm
Circuit breaker
DB252,X233.7 ALARM_HMI.MCC_SERVICE.SpareCB.CB32ASpare8Tripped 32A Spare 8
tripped Alarm
Circuit breaker
DB252,X234.0 ALARM_HMI.MCC_SERVICE.SpareCB.CB20ASpare1Tripped 20A Spare 1
tripped Alarm
Circuit breaker
DB252,X234.1 ALARM_HMI.MCC_SERVICE.SpareCB.CB20ASpare2Tripped 20A Spare 2
tripped Alarm
Circuit breaker
DB252,X234.2 ALARM_HMI.MCC_SERVICE.SpareCB.CB20ASpare3Tripped 20A Spare 3
tripped Alarm
Circuit breaker
DB252,X234.3 ALARM_HMI.MCC_SERVICE.SpareCB.CB20ASpare4Tripped 20A Spare 4
tripped Alarm
Circuit breaker
DB252,X234.4 ALARM_HMI.MCC_SERVICE.SpareCB.CB20ASpare5Tripped 20A Spare 5
tripped Alarm
Circuit breaker
DB252,X234.5 ALARM_HMI.MCC_SERVICE.SpareCB.CB20ASpare6Tripped 20A Spare 6
tripped Alarm
Circuit breaker
DB252,X234.6 ALARM_HMI.MCC_SERVICE.SpareCB.CB24VccTripped 24Vcc tripped
Alarm
Circuit breaker
400Vac PLC IO
DB252,X234.7 ALARM_HMI.MCC_SERVICE.SpareCB.CB400VacPLCIOTripped
module tripped
Alarm
Pagina 64 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Pump 1 - Main
DB252,X238.0 ALARM_HMI.HPU.Pump1MainPowerSwitch power switch
closed Alarm
Pump 1 - Main
DB252,X238.1 ALARM_HMI.HPU.Pump1MainPowerSwitchTrip power switch
tripped Alarm

DB252,X240.0 ALARM_HMI.HPU.Pump1DriveAlarm.Ready Ready Alarm

DB252,X240.1 ALARM_HMI.HPU.Pump1DriveAlarm.Run Run Alarm

Drive remote
DB252,X240.2 ALARM_HMI.HPU.Pump1DriveAlarm.Remote Alarm (Profibus
control disable)

DB252,X240.3 ALARM_HMI.HPU.Pump1DriveAlarm.Fault Drive Fault Alarm

DB252,X240.4 ALARM_HMI.HPU.Pump1DriveAlarm.Alarm Drive Alarm

Pump 2 - Main
DB252,X242.0 ALARM_HMI.HPU.Pump2MainPowerSwitch power switch
closed Alarm
Pump 2 - Main
DB252,X242.1 ALARM_HMI.HPU.Pump2MainPowerSwitchTrip power switch
tripped Alarm

DB252,X244.0 ALARM_HMI.HPU.Pump2DriveAlarm.Ready Ready Alarm

DB252,X244.1 ALARM_HMI.HPU.Pump2DriveAlarm.Run Run Alarm

Drive remote
DB252,X244.2 ALARM_HMI.HPU.Pump2DriveAlarm.Remote Alarm (Profibus
control disable)

DB252,X244.3 ALARM_HMI.HPU.Pump2DriveAlarm.Fault Drive Fault Alarm

DB252,X244.4 ALARM_HMI.HPU.Pump2DriveAlarm.Alarm Drive Alarm

Supercharging
pump 1 - Main
DB252,X246.0 ALARM_HMI.HPU.Supercharging1_CBClosed
circuit breaker
closed Alarm
Supercharging
pump 1 - Main
DB252,X246.1 ALARM_HMI.HPU.Supercharging1_CBTripped
circuit breaker
tripped Alarm
Supercharging
pump 1 - Main
DB252,X246.2 ALARM_HMI.HPU.Supercharging1_Running
contactor closed
Alarm
Pagina 65 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

DB252,X246.3 ALARM_HMI.HPU.Supercharging1_Spare01

DB252,X246.4 ALARM_HMI.HPU.Supercharging1_Spare02

Supercharging
pump 2 - Main
DB252,X246.5 ALARM_HMI.HPU.Supercharging2_CBClosed
circuit breaker
closed Alarm
Supercharging
pump 2 - Main
DB252,X246.6 ALARM_HMI.HPU.Supercharging2_CBTripped
circuit breaker
tripped Alarm
Supercharging
pump 2 - Main
DB252,X246.7 ALARM_HMI.HPU.Supercharging2_Running
contactor closed
Alarm

DB252,X247.0 ALARM_HMI.HPU.Supercharging2_Spare01

DB252,X247.1 ALARM_HMI.HPU.Supercharging2_Spare02

Supercharging
pump 3 - Main
DB252,X247.2 ALARM_HMI.HPU.Supercharging3_CBClosed
circuit breaker
closed Alarm
Supercharging
pump 3 - Main
DB252,X247.3 ALARM_HMI.HPU.Supercharging3_CBTripped
circuit breaker
tripped Alarm
Supercharging
pump 3 - Main
DB252,X247.4 ALARM_HMI.HPU.Supercharging3_Running
contactor closed
Alarm

DB252,X247.5 ALARM_HMI.HPU.Supercharging3_Spare01

DB252,X247.6 ALARM_HMI.HPU.Supercharging3_Spare02

Supercharging
pump 4 - Main
DB252,X247.7 ALARM_HMI.HPU.Supercharging4_CBClosed
circuit breaker
closed Alarm
Supercharging
pump 4 - Main
DB252,X248.0 ALARM_HMI.HPU.Supercharging4_CBTripped
circuit breaker
tripped Alarm
Supercharging
pump 4 - Main
DB252,X248.1 ALARM_HMI.HPU.Supercharging4_Running
contactor closed
Alarm
Pagina 66 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

DB252,X248.2 ALARM_HMI.HPU.Supercharging4_Spare01

DB252,X248.3 ALARM_HMI.HPU.Supercharging4_Spare02

Ups in by-pass
DB252,X250.0 ALARM_HMI.UPS.ByPass
Alarm
AC abnormal
DB252,X250.1 ALARM_HMI.UPS.ACAbnormal
Alarm

DB252,X250.2 ALARM_HMI.UPS.ACNormal AC normal Alarm

DB252,X250.3 ALARM_HMI.UPS.InverterOn Inverter On Alarm

DB252,X250.4 ALARM_HMI.UPS.BatteryLow Battery low Alarm

DB252,X250.5 ALARM_HMI.UPS.BatteryBad Battery bad Alarm

DB252,X250.6 ALARM_HMI.UPS.Alarm Alarm

Circuit breaker
DB252,X250.7 ALARM_HMI.UPS.CBMainClosed Power supply
closed Alarm
Main circuit
DB252,X252.0 ALARM_HMI.AirConditioner1.CBMainTripped breaker tripped
Alarm
Clivet circuit
DB252,X252.1 ALARM_HMI.AirConditioner1.CLIVETTripped breaker tripped
Alarm
Fan discharge on
DB252,X252.2 ALARM_HMI.AirConditioner1.FanDischOn
Alarm
Compressor block
DB252,X252.3 ALARM_HMI.AirConditioner1.Comp1HP 1 high pressure
Alarm
Compressor block
DB252,X252.4 ALARM_HMI.AirConditioner1.Comp1LP 1 low pressure
Alarm
Pagina 67 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Chapter 7 Supervision pages


The system is managed through operator panels located in P.C.R. electric cabin and in Dog House.
Here below the graphic pages are reported with the explanations relevant to the information and commands
which can be enabled from the pages themselves.

7.1) SUPERVISION PAGES

At the bottom of every page of supervision, you will find a navigation menu that allows quick access to various
HMI screens.

1 2 3 4 5 6 7 8 9

1 Call button page HOME


2 Call button page MUD PUMPS
3 Call button page HPU
4 Call button page GENERATORI
5 Call button page MUD AGITATORS
6 Call button page MUD TANKS
7 Call button page DIAGNOSTICA RETE PROFIBUS
8 Call button page LISTA ALLARMI
9 Indicator POWER LIMIT

At the top of every page of supervision, can be displayed in a window of the alarm system.

1 2 3

1 Date/time allarms indicator


2 Date/time confirmation allarms
3 Message indicator allarm
Pagina 68 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.a) Page start


Page of generic presentation of P.C.R. with main menu push-buttons.

1 Button stand-by of monitor

2 Recall button of general layout

1
3 Recall button waveforms main utillities
3

7.1.b) Page General Lay-Out


This is the main operating page which points out, in evident way, the status of the main distribution
switches, the status of the power supply generators and of the most important utilities.
It contains push-buttons to open the pages with the detail and the display of the main electrical
parameters.

1 Indication of power and current delivered by


the generator.
2 Indication of switch status (Green / Red-Open /
Closed)

1 3 Indication of current drawn by the user


2

3
Pagina 69 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.c) Pages Generator

1 Button opening of general switch

2 Button close of general switch

1 2
3 Indication generator ON/OFF
3 5
4 Indication generator switch OPEN / CLOSED
4

5 Buttons scrolling pages generators


6
6 Button reference waveforms
7 GENERAL LAYOUT call button page
7
Pagina 70 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.d) H.P.U. Page

6
3 1
4
7
5 2
8

10
9

11

12 13

1 START button main unit HPU


2 STOP button main unit HPU

3 Indicator engine running

4 Indicator engine ready for ignition

5 Switch CLOSED

6 Commands to monitor enabled

7 Units under maintenance

8 Emergency stop operated

9 User waveforms

10 Current Consumption Indicator

11 Selector mode AUTOMATIC - MANUAL

12 CHARGING SUPER START button

13 CHARGING SUPER STOP button


Pagina 71 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.e) Mud Pump Page

6 1 2
9
7
8
10
11
12

3 4

1 START button main engines MUD PUMP

2 STOP button main engines MUD PUMP

3 Interface enable button on the monitor entry No. pump strokes

4 Enable button of control pump No. stroke potentiometer (located in the DOG HOUSE)

5 Indicators No. pump strokes set by monitor / potentiometer

6 Indicator emergency button on the control panel operated locally (if present)

7 Indicator engine running

8 Indicator engine ready for ignition

9 Mud pump maintenance

10 Indicator local controls enabled


11 Indicator remote command enabled
12 Emergency stop operated
Pagina 72 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.f) Tanks page

3
2 4
5
6
7

1 Start button of trip tank pump

2 Stop button of trip tank pump

3 Indicator engine running

4 Indicator engine ready for ignition

5 Indicator local controls enabled

6 Indicator enabled remote controls

7 DOG HOUSE Indicator commands enabled

8 Indicator emergency button user driven


Pagina 73 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.g) Pagina agitatori

1 5
2

1 Indicator engine ready for ignition

2 Indicator Engine enabled for operation

3 Enable button agitator operation

4 Button disabling agitator operation

5 Page call button of agitator spare


Pagina 74 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.h) Profibus Network Diagnostics Page

1 Profibus node status indicator

2 Display button configuration node (see section 7.1.i)


Pagina 75 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

7.1.i) Page display profibus nodes


Pagina 76 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Chapter 8 Procedures for electrical safety

Here below the procedures are listed to disconnect the electrical power supply to the utilities
relevant to plant HH350, powered by the Power Control Room.

The following operations must be executed only by qualified personnel.

8.1) INVERTER

Stated that, for every intervention on the considered parts, any electrical power supply must be
disconnected setting to OFF the relevant switch upstream the power supply line (see sections
referred to specific utilities), for any other intervention or procedure, refer to the following
manuals:

INVERTER ACS800 : ABB 3AUA0000068936

8.2) GENERATORS PRAMAC

To ensure the safety of the interconnection lines between generators and electrical cabin
(PCR), turn the key switch present on the command power unit on the generator to position
OFF/RESET. For any intervention on the electrical parts of the generator itself, refer to the
manual and the procedures specified by the manufacturer.

8.3) MANIPOLATORE ASTE

Electric panel: In electrical drawing identified by code U36.1


In cabin PCR, set the switch QF36.1 present on panel 47017058 to position OFF to disconnect
the power supply to all the 400VAC parts, set the switch S01 present on panel 47017053 to
position OFF.
After this operation, electrical power supply is cut to all the parts of the drill pipe handler.
Pagina 77 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

8.4) POMPE 12T1600AC

8.4.a) Pump 1

Motor A in AC: In electrical drawing identified by code M1.1


In cabin PCR, set the fuse breaker QS1.1 present on panel 47017054, upstream the relevant
VFD, to position OFF. Turn the key switch SA1.1 present in the command section of panel
47500504.1 to maintenance position. Remove the tongue of maintenance contact present over
the motor.

Motor B in AC: In electrical drawing identified by code M1.2


In cabin PCR, set the fuse breaker QS1.2 present on panel 47017054, upstream the relevant
VFD, to position OFF. Turn the key switch SA1.2 present in the command section of panel
47500503.1 to maintenance position. Remove the tongue of maintenance contact present over
the motor.

Electrical motor of lubrication pump: In electrical drawing identified by code M1.1.7.


In cabin PCR, set the switch QF1.1.7 present in panel 47017052 to position OFF.

Electrical motor of liner washing pump: In electrical drawing identified by code M1.1.6.
In cabin PCR, set the switch QF1.1.6 present in panel 47017052 to position OFF.

Motor A fan: In electrical drawing identified by code M1.1.5.


In cabin PCR, set the switch QF1.1.5 present in panel 47017052 to position OFF.

Motor B fan: In electrical drawing identified by code M1.2.5.


In cabin PCR, set the switch QF1.2.5 present in panel 47017052 to position OFF.
Pagina 78 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

8.4.b) Pump 2

Motor A in AC: In electrical drawing identified by code M2.1


In cabin PCR, set the fuse breaker QS2.1 present on panel 47017055, upstream the relevant
VFD drive to position OFF. Turn the key switch SA2.1, present in the command section of
panel 47500504.2 to maintenance position. Remove the tongue of maintenance contact
present over the motor.

Motor B in AC: In electrical drawing identified by code M2.2


In cabin PCR, set the fuse breaker QS2.2 present on panel 47017055, upstream the relevant
VFD drive to position OFF. Turn the key switch SA2.2, present in the command section of
panel 47500503.2 to maintenance position. Remove the tongue of maintenance contact
present over the motor.

Electric motor of lubrication pump: In electrical drawing identified by code M2.1.7.


In cabin PCR, set the switch QF2.1.7 present in panel 47017052 to position OFF.

Electric motor of liner washing pump: In electrical drawing identified by code M2.1.6.
In cabin PCR, set the switch QF2.1.6 present in panel 47017052 to position OFF.

Motor A fan: In electrical drawing identified by code M2.1.5.


In cabin PCR, set the switch QF2.1.5 present in panel 47017052 to position OFF.

Motor B fan: In electrical drawing identified by code M2.2.5.


In cabin PCR, set the switch QF2.2.5 present in panel 47017052 to position OFF.
Pagina 79 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

8.5) MAIN HYDRAULIC POWER UNIT (HPU)

Motor 1: In electrical drawing identified by code M7.1


In cabin PCR, set the fuse breaker QS7.1 present on panel 47017056, upstream the relevant
VFD drive to position OFF. Turn the key switch SA7.1, present in the command section of
panel 47500502.1 to maintenance position.

Motor 2: In electrical drawing identified by code M7.2


In cabin PCR, set the fuse breaker QS7.2 present on panel 47017056, upstream the relevant
VFD drive to position OFF. Turn the key switch SA7.2, present in the command section of
panel 47500507.1 to maintenance position.

Supercharging pumps: In electrical drawing identified by code M7.3, M7.4, M7.5, M7.6.
In cabin PCR set the switches QF7.3, QF7.4, QF7.5 e QF7.6 present in panel 47017052 to
position OFF.

HPU panel: In electrical drawing identified by code U7.7.


In cabin PCR set the switch QF7.7 present on panel 47017052 to position OFF.

Lighting and services: In electrical drawing identified by code U7.9.


In cabin PCR set the switch QF7.9 present on panel 47017058 to position OFF.

8.6) DRILLING RIG

Line 1 for Drilling Rig lighting and services: In electrical drawing identified by code U7.10.
In cabin PCR set the switch QF7.10 present on panel 47017058 to position OFF.

Line 2 for Drilling Rig lighting and services: In electrical drawing identified by code U7.11.
In cabin PCR set the switch QF7.11 present on panel 47017058 to position OFF.

8.7) SNUBBING HPU

Electric motor: In electrical drawing identified by code U10.1.


In cabin PCR set the switch QF10.1 present on panel 47017058 to position OFF.
Pagina 80 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

8.8) MIXING PUMPS

Mixing pump 1: In electrical drawing identified by code M12.1.


In cabin PCR set the switch QF12.1 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

Mixing pump 2: In electrical drawing identified by code M12.2.


In cabin PCR set the switch QF12.2 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

8.9) MUD DEGASSER

Electric motor: In electrical drawing identified by code M13.1.


In cabin PCR set the switch QF13.1 present on panel 47017052 to position OFF.

8.10) TRIP TANK PUMPS

Trip tank pump 1: In electrical drawing identified by code M14.1.


In cabin PCR set the switch QF17.1 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

Trip tank pump 2: In electrical drawing identified by code M14.2.


In cabin PCR set the switch QF14.2 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

8.11) WATER PUMP

Water pump 1: In electrical drawing identified by code M15.1.


In cabin PCR set the switch QF15.1 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

Water pump 2: In electrical drawing identified by code M15.2.


In cabin PCR set the switch QF15.2 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.
Pagina 81 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

8.12) MUD PUMPS 12T1600AC SUPERCHARGING PUMPS

Mud pump 1 supercharging pump: In electrical drawing identified by code M1.1.8.


In cabin PCR set the switch QF1.1.8 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

Mud pump 2 supercharging pump: In electrical drawing identified by code M2.1.8.


In cabin PCR set the switch QF2.1.8 present on panel 47017052 to position OFF.
Set the proper push-button/selector, present on the local panel, to maintenance position.

8.13) ELECTRAGITATORS

Electric motors: In electrical drawing identified by codes M16.1, M16.2, M16.3, M16.4, M16.5,
M16.6, M16.7, M16.8, M16.9, M16.10, M16.11, M16.12, M16.13
In cabin PCR set the relevant switches QF16.1, QF16.2, QF16.3, QF16.4, QF16.5, QF16.6,
QF16.7, QF16.8, QF16.9, QF16.10, QF16.11, QF16.12, QF16.13 present on panel 47017052
to position OFF.

8.14) AIR COMPRESSOR

Electric motors: In electrical drawing identified by codes M17.1, M17.2


In cabin PCR set the relevant switches QF17.1 and QF17.2 present on panel 47017052 to
position OFF.

8.15) SHALE SHAKER

Electric motors: In electrical drawing identified by codes M32.1, M32.2, M32.3.


In cabin PCR set the relevant switches QF32.1, QF32.2, QF32.3 present on panel 47017052
to position OFF.

8.16) BOP ACCUMULATOR

Pump: In electrical drawing identified by code U30.1.


In cabin PCR set the relevant switch QF30.1 present on panel 47017058 to position OFF.
Pagina 82 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

8.17) MUD TANK ELECTRIC PANELS

Utility: In electrical drawing identified by codes U47.1, U47.2, U47.3, U47.4, U47.5, U47.6,
U47.7. In cabin PCR set the relevant switches QF47.1, QF47.2, QF47.3, QF47.4, QF47.5,
QF47.6, QF47.7 present on panel 47017058 to position OFF.
.

8.18) RESERVE AND SERVICES

Utility: In electrical drawing identified by codes U40.1, U41.1, U42.1, U42.2, U42.3, U43.1,
U43.2, U44.1, U44.2, U45.1, U45.2, U46.1, U46.2, U46.3, U46.4, U46.5
In cabin PCR set the relevant switches QF40.1, QF41.1, QF42.2, QF42.3, QF43.2, QF44.1,
QF44.2, QF45.1, QF45.2, QF46.1, QF46.2, QF46.3, QF46.4, QF46.5 present on panel
47017058 and QF42.1, QF43.1 present on panel 47017052 to position OFF.

8.19) POWER TRANSFORMER

1250KVA transformer: In electrical drawing identified by code T07.1


In cabin PCR set the upstream switch, QF07.1 and the two downstream switches QF07.11
and QF07.12 present on panel 47017057 to position OFF, to achieve the full insulation of the
transformer from the system

8.20) AIR-CONDITIONERS

Machine1: In electrical drawing identified by code U011.1


In cabin PCR set the switch QF011.1 present on panel 47017052 to position OFF.

Machine2: In electrical drawing identified by code U011.2


In cabin PCR set the switch QF011.2 present on panel 47017052 to position OFF.
Pagina 83 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

Chapter 9 Annexes
SCHEDA TECNICA GENERATORI PRINCIPALI
Pagina 84 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

SCHEDA TECNICA TRASFORMATORE


Pagina 85 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

SCHEDA TECNICA SISTEMA A SBARRE 600V

SCHEDA TECNICA SISTEMI A SBARRE QUADRO PRESE 400V


Pagina 86 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

INVERTER MOTORI UTENZE PRINCIPALI 600V


Pagina 87 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A
Pagina 88 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

COMPONENTI IMPIANTO ILLUMINAZIONE


Pagina 89 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A
Pagina 90 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A
Pagina 91 di 91
DESIGN Data 10/06/11
HH350B Plant Power supply System Rif. PCR-003A

ALTRA DOCUMENTAZIONE

Schema elettrico generale 47006012


Schema elettrico manipolatore aste 47006038
Manuali e fogli componenti
Cd con manuali, fogli componenti e schemi elettrici.