The document outlines the technical specifications for a Pre-Engineered Building (PEB) project in Bidkin Aurangabad, detailing design codes, material requirements, and construction parameters. It includes load specifications, geometry, materials, and design parameters, along with commercial terms and conditions. Additionally, it provides a schedule for design, delivery, site preparation, erection, and finishing phases of the project.

Uploaded by

Karan Prabhakar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views6 pages

Peb Technical Specs MJ Casting

The document outlines the technical specifications for a Pre-Engineered Building (PEB) project in Bidkin Aurangabad, detailing design codes, material requirements, and construction parameters. It includes load specifications, geometry, materials, and design parameters, along with commercial terms and conditions. Additionally, it provides a schedule for design, delivery, site preparation, erection, and finishing phases of the project.

Uploaded by

Karan Prabhakar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

PEB Specification For BIDKIN AURANGABAD

Technical Specification Remarks

Sl. No. Particulars Requirement


Reference drawing number
Part-A: DESIGN
AISC – 360 – 2016 (ASD) for Built-up Members
1 Design Code Load combinations as per
ASCE – 7 – 16 & Serviceability according to MBMA – 2018
1.1 Bulding Type Partially Enclosed
Roof Live Load 0.57 KN/m2
2
Roof Dead Load 0.15 KN/m2
2.1 Collateral Load on Roof NA
2.2 Solar Panel Load 0.25 kn/ sqm solar panel Load on Rafters & Purlins
2.3 Collateral Load on Column 200 Kg/RMT
2.4 Collateral Load on Rafter NA

3 Wind Speed/ Internal pressure/ Eqk Zone As applicable at BIDKIN AURANGABAD Zone Design as per IS 875: Part-III 2015
4 Cranes 50 ton & 10 ton 3 crane
5 Building Location BIDKIN AURANGABAD
Part-B: GEOMETRY
1 Roof Slope 1:20
2 Length C/C as per drawings
3 Width C/C as per drawings
4 Clear height as per drawings Column base plate 200 mm below FFL
5 Frame type MULTI SPAN (MS)
6 Bay Spacing As per Drawing
7 Crane Numbers 3 50 ton &10 ton capacity without tendom operation applicable
8 Staircases as per drawing
9 Purlins/ Sidewall girts/ End wall Girts AZ-150 AZ-150 (galvalume)
10 Future Expansions at Y10
11 Brick wall Height 450 for main building

12 Framed Openings with flashing As per Drawing

13 Rolling Shutters with flashing As per Drawing

14 Canopy With Sofit Yes with gutter 0.5mm TCT and Downtake

15 Mezzanine As Shown in draiwngs dispatch area with soffit below mezzanine

16 Load on Mezzanine 500kg/sqm

17 Wind Bracing Pipe Bracing in roof & Wall portal at opening location 5 mtr height (no cross at FFL)

18 Column shape - Straight Straight 200 mm below FFL

19 Wire Mesh - GI Weld Mesh 75x75x1.6 mm Yes In roof

20 Roof Light as mentioned in drawing PC Sheet in Low and High-way area as shown in drawings

21 Lean to Roof Sheet type Screw Down sheet SMP finish 0.50mm TCT. AZ150 having YS 550MPA
22 Roof monitor N/A RAL-9002
Part-C: MATERIAL
1 Roof Sheet Standing Seam 0.55 mm Bare Galvalume

2 Daylight Panels % age As per Drawing

3 Wall Sheeting Scew Down SDP finish, 0.50mm TCT, PPGL, AZ150 having YS 550MPA

4 Wall Liner Upto 5 MTR Ht from FFL No sub girts and flange bracing upto 5 MTR HT

5 Deck Sheeting Thicknes 1 mm thick 120 GSM

6 Ridge Vents N/A


7 Built Up Section ASTM A572 Gr50 (345Mpa)/ IS 2062 E350 or equivalent
8 Turbo vents N/A
9 Accessories All trim and flashing will be as wall sheet specification
1. All primary connection bolts grade HT 8.8
IS 1367 or as per ASTM A 325 M or equivalent Class-4
10 Screw and Fasteners 2. All secondary and anchor bolts grade HT 4.8
( EJOT/Corroshield/Roofix)
3. All screw must have screw cap RAL-9002
Design as per topography survey and cloud bust condition in
11 Rain water Gutter Eave type SDP finish 0.50mm TCT. AZ150 having YS 550MPA. RAL-9003
the region, minimum 150 mm/hr
2 Nos at each column SDP finish 0.50mm TCT. AZ150 having YS 550MPA.
12 Downspouts for rain water
RAL-9003
One coat PU final painting will be done at site 40 Microns
13 Painting- Primary & secondary members As per painting scheme options attached
with maintenance walkway 750 mm wide & railing and monkey
14 All crane beams and brackets 10 mtr from FFL
ladder
15 Structural partitions As Shown in draiwngs

16 Louvers N/A

17 Insulation 4mm bubble insullation for roof & lean to (Aerolam/Alutix)


Part-D: Design Parameters
1 Design Software As per Standard
2 Min thickness of plates As per Design
3 Min thickness cold form sections As per Design
4 Steel Line As per Drawing
5 Crane Data Refer electomac/K2 crane data
6 Crane impact Load 25%
7 Secondary members design IS: 801 1975 reaffirmed in 2010
8 Wind Load calculation IS 875: Part-III 2015
9 Seismic Loads IS: 1893 Part I - 2016 & IS: 1893 Part IV - 2015
10 Stress Ratio 0.99
11 Deflection Limits As per Design
12 Welding Double Side AWS D1.1 M:2015
13 Damping Factor 0.02

NOTES:
1 Submit Workplan and delivery schedule with your Offer.
2 Enclose a proposal drawing with your offer.

3 Submit a declaration of confirmation to specs and drawing issued by us and deviations, if any.
Submit approx. Tonnage Breakup for main frame, Crane beams, Mezzanine, Cold form, Other secondary members, sheeting in sq.m & Tons, in
4 ±5%
5 Erection Notes:
Electrical & Water arrangement shall be in PEB supplier Scope.

All erection shall be done with Boom Lift, Farhana, Aluminium Scaffolding & all safety standards.

Site Engineer and Safety Officer in PEB supplier Scope.


ABG against advance and PBG shall be provided by PEB suppliers
6 In the End:

a) You have to ensure perfect alignment of flashings, trims at corner & edges. Any waviness will not be accepted.

b) Before Sheeting installation, the alignment and level of purlins and Girts shall be checked by our engineer.

c) Submit a Stability certificate and final as built GA/AB drawings and a set of erection drawings for our records.

d) Advance payment will release against ABG and PBG of 5 % is to be given for one year.
GST will be paid post Reflecting on GST portal
Commercial Terms & Conditions
Prices:
Supply Lump Sum

Quantity Estimated:
Built Up, MT
Purlin & Girt, MT
Other cold Form, MT
Sheeting Roof Area, m2
Roof Sheeting Tonnage, MT
Wall Cladding Area, m2
Wall Cladding Tonnage, MT
Gutter, rmt. Inclusive
Downtake Inclusive

Erection Charges
Taxes / duty Inclusive
Excise Duty on Supply Inclusive
Freight Inclusive
Entry Tax / Octroi Inclusive
Unloading Inclusive
Transit & Erection Insurance Inclusive
Painting
Grand Total

Area
Price per Sq.mt
Price per Sq.feet
Insulation NA

LD Clause
Delay in Drawing Phase 0.5 % per day limited to 5% of contract value
Delay in Supply Phase 0.5 % per day limited to 5% of contract value
Delay in Completion & Handing Over 0.5 % per day limited to 5% of contract value
SPECIAL NOTES
Following Test reports will be submitted
1. Stability certificates.
2. Quality Certificates
3. Dimensional Inspection Report
4. Magnetic Particles Test Report
5. Welding Inspection Report
6. Liquid Penetration Test Report
7. Ultrasonic Test Report
8. Painting Inspection Report
Make : -Hempel 1 MT = 20 SqM
Paint coat Product VS% DFT TSR
Epoxy Zn phosphate primer Hempadur Fast Dry 17410 74 70 11
Intermediate Coat Hempaprime Core 500 81 100 8.1
Option 1
PU Topcoat Hempathane HS 55610 67 40 17
Thinners @ 20%
Total cost for material supply 210

1 MT = 20 SqM
Paint coat Product VS% DFT TSR
Epoxy Zn phosphate primer Hempadur Fast Dry 17410 74 70 11
Intermediate Coat Hempadur Fast Dry 17410 74 100 7.4
Option 2
PU Topcoat Hempathane HS 55610 67 40 17
Thinners @ 20%
Total cost for material supply 210

One Coat of PU paint at site of


40 Micron
Loss PSR Area Paint volume Price / Ltr Paint Value Cost / SqM Per MT Cost Per KG Cost
40% 6.3 22200 3500 300 1050000 47 946 0.9
30% 5.7 22200 3915 300 1174603 53 1058 1.1
30% 11.7 22200 1893 550 1041365 47 938 0.9
22200 1862 190 353732 16 319 0.3
22200 11170 3619700 163 3261 3.3

Loss PSR Area Paint volume Price / Ltr Paint Value Cost / SqM Per MT Cost Per KG Cost
40% 6.3 22200 3500 300 1050000 47 946 0.9
30% 5.2 22200 4286 300 1285714 58 1158 1.2
30% 12 22200 1893 550 1041365 47 938 0.9
22200 1936 190 367806 17 331 0.3
22200 11615 3744885 169 3374 3.4
Paint Ltr required per KG Paint Ltr required per MT
0.158 3.153
0.176 3.527
0.085 1.706
0.084 1.677
0.503 10.063

Paint Ltr required per KG Paint Ltr required per MT


0.158 3.153
0.193 3.861
0.085 1.706
0.087 1.744
0.523 10.464
MJ casting Schedule
Phase Activity Start Date End Date Duration(Days) Responsibility
1. Design Phase Qoute Submission 7/10/2025 7/15/2025 5
Client requirements finalization 7/15/2025 7/16/2025 1
Structural design File and AB Plan Submission 7/16/2025 7/19/2025 3
AB Plan and Stad Approval 7/19/2025 7/21/2025 2
GA Drawings Submission 7/21/2025 7/27/2025 6
GA Drawings Approval 7/27/2025 7/29/2025 2

2. Delivery Anchor Bolt of all building 7/21/2025 7/28/2025 7


Primary Structure With Accessaries 8/28/2025 9/17/2025 20
Secondary Structure with Accessaries 9/2/2025 9/22/2025 20
Sheeting With Accessaries 9/7/2025 10/7/2025 30
3. Site Preparation Foundation and anchor bolt installation 7/28/2025 8/27/2025 30
4. Erection Unloading and staging 8/28/2025 9/27/2025 30
Erection of primary members 9/7/2025 10/17/2025 40
Installation of secondary members 9/7/2025 10/17/2025 40
Roof and wall cladding 10/2/2025 11/11/2025 40
Accessories installation (doors flashing,
5. Finishing 10/27/2025 11/16/2025 20
windows Flashing, Gutter, Downtake )
Final inspection and handover 11/16/2025 11/26/2025 10 90 3