PROCEDURE FOR ETHERNET OPERATION THROUGH FANUC
PROGRAM TRANSFER TOOL
SET THE FOLLOWING PARAMETERS FOR ETHERNET OPERATION (APPLICABLE FOR FANUC 0-
I MF SERIES CNC SYSTEMS)
NO 20 = 9 (I/O CHANNEL SETTING FOR ETHERNET TRANSFER)
NO 138#7 = 1 (DNC OPERATION WITH MEMORY CARD ENABLE)
14885 =1 (ISO NEED TO BE 1)
1). MACHINE SIDE
SELECT MDI MODE
Press System Soft Key
Press Right Arrow Key till Embedded Soft Key appears
Choose available device as EMBEDDED by pressing Embedded soft Key
Common Embedded Screen will appear and fill the following details as shown in fig.
IP Address – Eg. 192.168.1.1(Machine IP Address)
Subnet Mask – 255.255.255.0
Restart and Execute to save the data.
Press FOCAS2 Soft key
Input the Details as given below :
PORT NUMBER (TCP) – 8193
PORT NUMBER (UDP) – 0
TIME INTERVAL - 10
Restart and Execute to save the data.
Press the FTP TRANS soft key
Fill the details as given below :
HOST NAME ( IP ADDRESS ) -- 192.168.1.1(Machine IP Address)
PORT NUMBER -- 21
USER NAME -- AMS
PASSWORD -- AMS
LOG IN FOLDER -- /AMS
Restart and Execute to save the data.
2). PC SIDE
Open the PC Ethernet Setting and open the Internet Protocol Version 4 (TCP/IPv4)
Properties
And Input the IP Address eg.192.168.1.2 & Subnet mask as 255.255.255.0P
(PC IP Address)
Install the Program Transfer Tool app
Finish the installation
Open the Setting Dialog by window button pressing and selecting the Setting dialog at
Program Transfer Tool drop down.
First click on Machine Info. And choose the given details:
Machine Number -- 1
Machine Name -- AMS
CNC Type -- Series oi-F
Control Path -- 1
And SAVE
Now click on Program Memory and fill the following details :
Ethernet Type -- Embedded Ethernet
IP Address -- 192.168.1.1(Machine IP Address)
TCP Port No. – 8193
Communication Timeout -- 10
And SAVE
Now click on Data Server and fill the following details :
IP Address -- 192.168.1.2(PC IP Address)
User Name . – 8193
Password -- AMS
FTP Port No. -- 21
Login Folder -- /AMS
And SAVE
Now click on Display and select the following details :
Make a folder in “C” Drive and create its shortcut on desktop. And select in “PC folder to be
displayed when communication is started”.
Select “Program Memory” in CNC device for communication startup.
And SAVE
Now again select the Program Memory and press “Communication Setting confirmation” and
one more window will appear as shown in fig.
If communication is proper established , then it will show the the all details
e.g. Get System information test
CNC type
M/T M
Series D4G3
Version 22.0
Max. Axes 3
Axes 3
Again open the machine Ethernet setting, Click on next/+ and Press the PING
Press OPRT and Press PING FTP1
Now machine Enthernet communication setting is completed , and now open the main Fanuc
Program Transfer Tool software, Before opening the Program Tranfer Tool Software close
Setting Dialog
Now it will shows the AMS Folder created in “C” Drive (keep folder shortcut at desktop) and
machine programs .