0% found this document useful (0 votes)
23 views3 pages

CU250KVA

The document provides specifications for the C-250 and C-275S gensets, detailing their prime and standby ratings, engine technical data, and alternator technical data. It includes information on control panel specifications, standard and optional features, as well as compliance with ISO standards. The gensets are designed for medium range applications, with additional notes on assembly, fabrication, and testing procedures.

Uploaded by

kaledhamou9
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views3 pages

CU250KVA

The document provides specifications for the C-250 and C-275S gensets, detailing their prime and standby ratings, engine technical data, and alternator technical data. It includes information on control panel specifications, standard and optional features, as well as compliance with ISO standards. The gensets are designed for medium range applications, with additional notes on assembly, fabrication, and testing procedures.

Uploaded by

kaledhamou9
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

C-250 C-275S (50Hz)

Gensets
Medium Range

Ratings @ 0.8 PF Prime Rating Stand-by Rating

Voltage 1 Frequency 2 C-250 3 C-275S 4

230/400 V 50 Hz 250kVA 275kVA

The above ratings represent the generating set capability guaranteed


within ±3% at the reference conditions equivalent to those specified in ISO
8528/1 standard.

Notes
EngineTechnical Data
1. The applicable voltage range is 380V to 415V
for 50Hz applications. For other voltages, please
consult factory.
Make & Model CUMMINS QSL9-G3

Cylinders & Arrangement 6; in-line


2. This generating set is of fixed speed of 1500
rpm. Bore & Stroke (mm) 114 x 145
Induction system Turbo charged & Aftercooled
3. C-250 is the prime power rating of the
generating set is where a variable load and Combustion Direct injection
unlimited hour usage are applied with an
average load factor of 80% of the prime rating Cycle 4 stroke
over each 24-hour period. Noting that a 10% Compression ratio 17.8:1
overload is permitted for 1 hour in every 12-hour
operation. Cooling System Water cooled
Displacement 8.8 liters
4. C-275S is the standby power rating of the
generating set is where a variable load limited Lube oil capacity 26.5 liters Max
to an annual usage up to 500 hours is applied,
Coolant capacity 11.0 liters
with 300 hours of which may be continuous
running. Noting that no overload is permitted. Standard governor (Optional) Electronic
Engine Speed 1500 rpm
Fuel Consumption (L/H) @ 100% Load 59.0 @ 50% Load 34.0
Fuel Consumption (L/H) @ 75% Load 49.0 @ 25% Load 18.0
Certi�cation Radiator Cooling Air Flow (m3/s) 7.9

The complete Generating Set is Emissions regulations For non-regulated territories


type-tested according to Exhaust temperature oC (max) 585
ISO 8528-8 Standard. Max exhaust gas �ow (m /s) 3
51.0
The control panel is certified by an ISO Max. allowed back pressure (kPa) 10.0
17025 accredited laboratory to have
The above performance data are valid as per the following specs:
IP55 in compliance
• Diesel Fuel is according to BS2869 Class A2 or equivalent.
with IEC 60355.
• Lubricating oil is according to Grade SAE 15W-40 API CI4.
• The coolant should be 50% antifreeze and 50% fresh water.

Dimensions Alternator Technical Data


Length 3000 mm Make & Model Leroy Somer TAL046D

Frequency / No. of poles 50Hz / 4P Winding pitch 2/3


Width 1100 mm
Ingress protection IP23 AVR model R150 1 MX321 2
Height 1800 mm
Insulation class H Overspeed 2250 R.P.M.
Weight 1800 Kg
Terminals (Optional) 6 (12) Voltage regulation ± 1 %

Excitation system SHUNT Coolant air �ow 0.48m3/s

Forcify FZC | Hamriyah Free Zone - Sharjah, UAE


Tel: +971 6 704 3545 | Mob.: +971 55 1977 773 | [email protected] | www.forcify.com
C-250 C-275S (50Hz)

Gensets
Medium Range

Control Panel Speci�cations Construction


Sheet Fabrication • CNC shearing & bending
DSE 6020MKII panel is an automatic start generating
Paint Type • Heat-treated powder-coated
set panel of microprocessor-based design which is
capable of interfacing with electronic engine Paint Application • Electrostatic corona spraying
through the can-bus J1939. • IMPACT [EN ISO 6272]
It is fully configurable and can be monitored by front Durability tests • Salt spray resistance [ASTM B117-73]
fascia buttons or PC software. ComAP AMF9 / 25 can • Humidity Resistance [ASTM D2247]
be also offered • Panel is compliant with [ISO8528-8]
Circuit Breaker Schneider ABB LS, 3 Pole MCCB (4 Pole • Clearance & Creepage [IEC60355-1]
Compliance
available as Optional) • Leakage current & Dielectric strength [IEC60355-1]
• Protection against electric shock [IEC600 364-4-41]
Desgree of Protection IP55
• Crimping force up to 20KN
Wire Crimping • Accuracy of 0.01mm
• Each crimping is checked by Komax CFA+
• Wires are coded by wire color and cross-section
Wire Coding • Wires are coded by printed numbers
• Wires are coded by printed function of the wire

Protection Control Instrumentation


(Standard) (Optional 1, 3) (Standard) (Optional 1) (Standard) (Optional 1, 3)

Over /under High Oil Remote Start Battery Changer: Gen AC Voltage: Lube Oil
AC Voltage Temperature Input 5A, 10A, UL 3ph VLL & VLN Temperature

Over /under High Exhaust Emergency Stop


Fuel Pump Control Gen Frequency: Hz Exhaust Temperature
Frequency Temperature Button

Delayed Common Alarm Gen Current: 3 Engine Inlet air (Boost)


Low Fuel Pressure Extension
Over Current Volt-free Contact Phase A pressure

Event Log Ethernet – Modbus Power: KW, KVA,


Short-circuit Low Coolant Pressure Charging ammeter
(50 Events) TCP KVAR & PF

RS485- Modbus Energy: KWhr, KVAhr,


Over KW Low Fuel Level Weekly Exerciser Fuel pressure
RTU KVARhr

High Engine
Low Oil Level Audible Alarm Webnet – GPS Tracker Lube Oil Pressure Coolant pressure
Temperature

Low Oil High Winding Standard Water In Fuel Engine Coolant


Fuel level
Pressure Temperature Canbus J1939 Detection Temperature

Maintenance High Bearing


Preheat Control Battery DC Voltage Lube oil level
Alarm Temperature

High/low Battery DC Alternator Winding temperature


Low Boost Pressure
Voltage Voltage 3xRTD

Low Coolant Fusible Link Fire Bearing temperature


Engine Speed
Level 2 Protection RTD

Low coolant temperature Operating Hours

1
Some OPTIONAL features could be standard if CANbus is established within electronic engines.
2
Low coolant level protection is standard feature for Gensets above 200KVA, otherwise it is optional.
3
There is limitation in the number of protections and measurements that can be offered with GMP260MK.

Other types of control Panels & Modules can be offered according to required specifications (DSE 7310/20, 7410/20, 8610, 8810 and Others).

Forcify FZC | Hamriyah Free Zone - Sharjah, UAE


Tel: +971 6 704 3545 | Mob.: +971 55 1977 773 | [email protected] | www.forcify.com
C-250 C-275S (50Hz)

Gensets
Medium Range

Genset Standard Features

Assembly
• Gensets are assembled at Forcify FZC in compliance with ISO 8528-8
standard.

Fabrication
• The engine/alternator assembly rests on skid with Anti-vibration
mounting pads.
• The skid is made up of durable sheet metals and beams exceeding
“Vibration & Torsion” Resistance Norms.
• A skid mounted fuel tank is supplied with fuel gauge, filler cap, fuel inlet
and outlet hoses.
• The control panel enclosure is made up of metal sheet.
Paint Genset Optional Features
• The skid and control panel enclosure are painted with heat-treated
and power-coated electrostati corona spraying. • Manual & Automatic Transfer Switches
• Paints passed durability tests conforming to international quality • Synchronizing & Totalizing Panels
standards. • Fuel water separator
• Impact (EN ISO 6272) • Water jacket heater
• Salt Spray Resistance (ASTM B117-73) • Oil heater
• Humidity Resistance (ASTM D2247) • Fuel heater
• Battery heater
Works-Testing • Anti-condensation Heater
• All Gensets are tested prior to dispatch. • Air Shut-off Valve
• Test is automatically generated and checked according to ISO8528 • Oil Sampler
• Test certificate is issued for each Genset • Pre-lube Oil Pump
Equipment
• Water cooled Radiator with belt driven blower fan and full guarding.
• Electric starter with solenoid Relay.
• Battery Charging Alternator.
• Energized to run solenoid.
• Replaceable fuel, oil, and air filters.
• Heavy duty leads acid battery with matching capacity (Amps & CCA).
• One loose supplied industrial exhaust silencer – 16 DB noise reduction level.
• Integral Fuel Tank with 150L capacity.
Documentation
• User Manual for Operation, Installation and Maintenance guidance.
• Wring Diagram.
• Test Report.
• Maintenance Schedule.
• Catalogues for Engine, Alternator & AVR.

Forcify FZC | Hamriyah Free Zone - Sharjah, UAE


Tel: +971 6 704 3545 | Mob.: +971 55 1977 773 | [email protected] | www.forcify.com

You might also like