HygroPro XP
Aluminum Oxide
Moisture Transmitter
Applications Features
This explosionproof aluminum oxide moisture transmitter • Explosionproof
measures moisture concentration in gases and non-aqueous
• Ambient to ppb-level moisture measurement using next-
liquids from trace to ambient levels. It is suitable
generation aluminum oxide moisture sensor
for a wide range of applications including:
• Built-in temperature sensor for temperature compensation
• Petrochemical
• Optional pressure sensor
• Refinery
• Calibrations traceable to National Institute of Standards
• Natural gas
and Technology (NIST) or National Physical Laboratory (NPL)
• Hydrogen with the option of fully accredited calibration to
ISO 17025
• Industrial gas
• Complete programming capability via User Interface that
• Power generation
consists of integrated display and 6-button keypad
• Analog and digital outputs
• HART communication over the 4 – 20 mA analog output
• Electropolished 316/316L enclosure option
• Real-time clock for automatic calibration reminder
The HygroPro XP moisture transmitter is a compact, 4–20 Advanced moisture sensor technology
mA transmitter designed to meet the needs of the most
The HygroPro XP combines a technologically advanced
demanding hazardous area applications. It features an
aluminum oxide moisture sensor with onboard temperature
integrated backlit display with a six-button programmable
compensation, state-of-the-art hygrometry software,
keypad, housed in an IP66/Type 4X rated explosion proof
and robust read-out electronics for unequaled overall
enclosure. The integrated display and keypad allow easy
performance. The probe is maintained dry during shipment
navigation of the software for configuration of the probe
using high-capacity desiccant packs inside a metal
measurement, analog and digital (HART) output, and other
shipping cap, which if unscrewed just prior to installation on
user functions and diagnostics. The HygroPro XP has built-
the process, enables fast dry down.
in multi-drop networking capability via the digital HART
interface that allows multiple units to be connected on a
single network. Calibration traceable to international standards
Using an industry-proven state-of-the-art aluminum Superior sensitivity, speed of response, calibration stability,
oxide moisture sensor, the HygroPro XP features a built-in and wide dynamic range have made Panametrics aluminum
thermistor and optional pressure transducer to provide oxide moisture probes the standard of performance
real-time measurement of the sample dew/frost point, and value in industrial moisture measurement. They are
temperature and pressure. This allows for the calculation and suitable for process and industrial moisture measurement
display of other moisture content parameters such as ppmv applications in a wide variety of gases and hydrocarbon
in gases, ppmw in liquids, pounds per million standard cubic liquids over a wide range of process conditions. Calibration
feet in natural gas and more. traceability is available to the NIST or the NPL with the option
of an ISO 17025 accredited calibration.
The glass-to-metal seal in the probe mount is certified to
meet ANSL/UL 122701 single seal standards ensuring reliable
isolation of the probe electronics from the process.
The HygroPro XP consists of a display head and a replaceable
transducer element (RTE), which contains the aluminum
oxide moisture sensor, thermistor and optional pressure
transducer with associated electronics. The calibration data
for the moisture and pressure sensors are stored on a non-
volatile EEPROM in the RTE, the user does not need to enter any
calibration data manually when changing an RTE.
Typical hazardous area installation showing connection to an
Analog output device/HART master.
HygroPro XP
specifications • Weight: Aluminium: 5.5lbs (2.5kg) Stainless Steel: 11lbs (5kg)
European compliance
Calibration ranges (dew/frost point) Complies with EMC directive 2014/30/EU
Standard: 50 to -112°F (+10 to –80°C) with data from Hazardous area certification
+68 to -166°F (+20 to -110°C) North America:
Operating temperature • Cl I,II,III Div 1/Div2, Gp ABCDEFG, T6
-4°F to 140°F (–20°C to 60°C) • Cl I, Zn 1, AEx/Ex db/ia IIC T6 Gb/Ga
Storage temperature • Cl II, Zn 21 AEx/Ex tb/ia IIIC T85°C Db/Ga
-22°F to 158°F (-30°C to 70°C) • Cl I, Zn 2, AEx/Ex dc/ia IIC T6 Gc/Ga
• Cl II, Zn 22 AEx/Ex tc/ia IIIC T85°C Dc/Da
Accuracy
• -20°C < Ta < +60°C
• ±3.6°F (±2°C) above -148°F (-100°C)
• ±5.4°F (±3°C) below -148°F (-100°C) ATEX/IECEx:
• Ex db/ia IIC T6 Gb/Ga
Repeatability
• Ex tb/ia IIIC T85°C Db/Ga
• ±0.4°F (±0.2°C) above -148°F (-100°C)
• 20°C < Ta < +60°C
• ±0.9°F (±0.5°C) below -148°F (-100°C)
Moisture sensor
Electrical
Sensor type
Power
Thin-film aluminum oxide moisture sensor
• Voltage: 12 to 28 VDC (loop-powered, customer supplied)
Calibration
• Output: 4 to 20 mA analog & HART digital
Each sensor is individually computer-calibrated against known
• Output Resolution: 0.01 mA/12 bits
moisture concentrations, traceable to national standards
Note: Class 2 rated power supplies (with functional GND)
are recommended. Calibration interval
Panametrics recommends moisture sensor recalibration
Display every six to twelve months depending on application
• 128 x 64 LED backlit LCD
• Display from one to three parameters and diagnostics Temperature sensor
Sensor type
Mechanical NTC thermistor
Sample connection
Operating range
• 3/4-16 in. (19 mm) straight male thread with O-ring
-22°F to 158°F (–30°C to 70°C)
• G 1/2 with optional adapter
Accuracy
Operating pressure
5 μm Hg to 5000 psig (345 bar) ±0.9°F (±0.5°C) overall
Enclosure Pressure sensor
Type 4X, IP 66
Sensor type
Dimensions Solid state/piezoresistive
• H x W x D: 8.63 x 4.80 x 3.51 in. (219 x 122 x 89mm)
Available ranges
• 30 to 300 psig (3 to 21 bar)
• 50 to 500 psig (4 to 35 bar)
• 100 to 1000 psig (7 to 69 bar)
• 300 to 3000 psig (21 to 207 bar)
• 500 to 5000 psig (35 to 345 bar)
Accuracy
±1% of full scale (FS)
Pressure rating
Three times the span of the specified range to a maximum of
7500 psig (518 bar)
HygroPro XP dimensions
Configuration options
Record selected option in blank spaces indicated at bottom of form.
HYGROPRO XP-B-C-D-E-F-G-H-I-J Option Code
A – Model only
HYGROPRO XP: HygroPro XP absolute moisture transmitter
B – Transmitter Head/Display
1 Aluminum
2 316 Stainless Steel
C – Pressure Transducer on Probe
0 None
1 30 to 300 psig pressure transducer
2 50 to 500 psig pressure transducer
3 100 to 1000 psig pressure transducer
4 300 to 3000 psig pressure transducer
5 500 to 5000 psig pressure transducer
D – Laboratory Services
0 None
1 Cleaning for oxygen service
E – Calibration Certification
0 None
1 NIST Certificate
3 ISO-17025 Calibration
4 NPL Certificate
F – O-ring Options
0 Standard Viton O-ring
1 Teflon O-ring
2 CPA-70 O-ring
3 Kalrez O-ring
G – Material Certification
0 None
1 NACE/EN 10204.3.1 Compliant
H – Calibration
0 Standard Calibration, -80 to +10 °C dew/frost point. Data from -110 to +20 °C.
1 Low-End Calibration, -100 to -50 °C dew/frost point. Data from -110 to -50 °C.
I – Hazardous Area Certification
1 US/Canada Class I Div 1, Zone 1/21
2 US/Canada Class I Div 2, Zone 2/22
3 ATEX/IECEx/UKEX Zone 1
J – Special
0 None
1 Special, Consult Factory
A-Model only B C D E F G H I J
Panametrics, a Baker Hughes business, provides solutions in
the toughest applications and environments for moisture,
oxygen, liquid and gas flow measurement. Experts in flare
management, Panametrics technology also reduces flare
emissions and optimizes performance.
With a reach that extends across the globe, Panametrics’
critical measurement solutions and flare emissions
management are enabling customers to drive efficiency
and achieve carbon reduction targets across critical
industries including Oil & Gas, Energy, Healthcare, Water and
Wastewater, Chemical Processing, Food & Beverage and
many others.
Join the conversation and follow us on LinkedIn
linkedin.com/company/panametricscompany
Copyright 2025 Baker Hughes Company. All rights reserved.
BHCS39493 R7 (04/2025) panametrics.com