Expansion Module

The F4-XPM series expansion modules enhance the Facility Explorer system by providing input/output capabilities for various controllers, including the PCG and PCV series. These modules can be connected to the Sensor/Actuator Bus or Field Controller Bus, allowing for flexible monitoring and control options. They are BACnet certified, support wireless integration, and come in multiple models with varying point types and specifications.

Uploaded by

Muhammad Adil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views7 pages

Expansion Module

The F4-XPM series expansion modules enhance the Facility Explorer system by providing input/output capabilities for various controllers, including the PCG and PCV series. These modules can be connected to the Sensor/Actuator Bus or Field Controller Bus, allowing for flexible monitoring and control options. They are BACnet certified, support wireless integration, and come in multiple models with varying point types and specifications.

Uploaded by

Muhammad Adil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

F4-XPM Expansion Modules Catalog Page

2023-12-12 LIT-1901150

XPM Expansion Modules • PCG series General Purpose Programmable


Controllers
Figure 1: F4-XPM series expansion modules • PCV16, PCV18, PCV19, and VAV17 series
Programmable Variable Air Volume Box
Controllers
• F4-SNC series Supervisory Controllers
Note: XPM series expansion modules may
coexist on the SA Bus with PCX series input/
output expansion modules.

You can connect XPM series expansion modules to


The F4-XPM series input/output (I/O) expansion the FC bus of the following supervisory controller
modules are part of the Facility Explorer system types:
CG, CV Equipment Controller family and can serve
in one of two capacities depending on where • FX80 Supervisory Controller
they are installed in the Facility Explorer system. • F4-SNC series Supervisory Controllers
When installed on the Sensor/Actuator (SA) Bus
of a Facility Explorer controller, an XPM expands Note: XPM series expansion modules may
the input and output interfaces that can be used coexist on the FC Bus with PCX series input/
with that equipment controller. When installed on output expansion modules.
the Field Controller (FC) Bus of a Facility Explorer
supervisory controller, an XPM can be used as
I/O point multiplexors to support monitoring
and control from a Facility Explorer supervisory Features and benefits
controller. The point multiplexor can also be useful
Sleek and modern packaging and styling
for sharing points between other equipment
controllers on the FC Bus using peer-to-peer Provides a modern, aesthetically pleasing industrial
connectivity. design.
XPMs operate on an RS-485 BACnet MS/TP Bus
and are BACnet Testing Laboratory (BTL) listed Standard hardware and software platform
and certified to the BACnet Smart Actuator (B-SA)
profile. Uses a common hardware design throughout
the family line to support standardized wiring
practices and installation workflows. Also uses a
Compatibility common software design to support use of a single
tool for control applications, commissioning, and
You can connect XPM series expansion modules to troubleshooting to minimize technical training.
the SA Bus of the following device types:
Ability to reside on the FC Bus or SA Bus
• CG series General Purpose Application
Controllers Provides application flexibility.
• CV series VAV Box Controllers
BACnet Testing Laboratories (BTL) listed and
• CCM Critical Environment Controller certified
• PCA series Advanced Application Programmable
Controllers Ensures openness and interoperability with other
BTL-listed devices. BTL is a third-party agency, which

F4-XPM04060, F4-XPM09090, F4-XPM18000

168
validates that BAS vendor products meet the BACnet the ability to quickly and easily install and service
industry-standard protocol. a device without the need to disconnect and
reconnect the input/output wiring.
BACnet automatic discovery
Decimal MS/TP address set with three rotary
Supports easy integration into a Facility Explorer switches
BAS.
Easy-to-use rotary switches set the MS/TP address
Wireless ZFR Pro support
in decimal format.
Wireless ZFR Pro support provides a wireless Universal Inputs and Configurable Outputs
alternative to hard-wired FC Bus MS/TP networking,
offering application flexibility and mobility with Allows multiple signal options to provide input/
minimal disruption to building occupants, and also output flexibility.
simplifies and speeds up replacements.
End-of-Line (EOL) switch
Pluggable screw terminal blocks
Enables devices to be terminating devices on the
Pluggable input/output wiring terminal blocks communications bus.
provide electrical installers and field technicians

XPM series model information


Table 1: XPM series information including point type counts
F4-XPM04060-0 F4-XPM09090-0 F4-XPM18000-0
Communication protocols BACnet MS/TP
Modular jacks SA/FC Bus Port: RJ-12 6-Pin Modular Jack
Point types Signals accepted Number of points
Universal Input (UI) 15 VDC Power Source (Provide 100mA total 3 7 0
current)
Analog Input - Voltage Mode (0–10 VDC)
Analog Input - Current Mode (4–20 mA)
Analog Input - Resistive Mode (0–600k ohm), RTD
(1k Nickel [Johnson Controls sensor], 1k PT, A998
SI), NTC (10k Type L, 2.252k Type 2)
Binary Input, Dry Contact Maintained Mode
Universal Input Common
Binary Input (BI) Binary Input, Dry Contact Maintained Mode 1 2 18
Binary Input - Pulse Counter/Accumulator Mode
Binary Input Common
Configurable Output (CO) Analog Output - Voltage Mode (0–10 VDC) 4 4 0
Binary Output 24 VAC Triac
Analog Output Signal Common
Binary Output Signal Common

2 F4-XPM Expansion Modules Catalog Page

169
Table 1: XPM series information including point type counts
F4-XPM04060-0 F4-XPM09090-0 F4-XPM18000-0
Analog Output (AO) Analog Output - Voltage Mode (0–10 VDC) 0 2 0
Analog Output - Current Mode (4–20 mA)
Analog Output Signal Common
Binary Output (BO) Binary Output - 24 VAC Triac (External Power 2 3 0
Source)
Binary Output Common

3 F4-XPM Expansion Modules Catalog Page

170
Ordering information and accessories
The following tables provide the product code number and description for the XPM models and accessories.
Table 2: XPM Series ordering information
Product code number Description
F4-XPM04060-0 10-point Input/Output Expansion Module
Includes: MS/TP communication; 10 points (3 UI, 1 BI, 4 CO, 2 BO); 24VAC input
F4-XPM09090-0 18-point Input/Output Expansion Module
Includes: MS/TP communication; 18 points (7 UI, 2 BI, 4 CO, 2 AO, 3 BO); 24VAC input
F4-XPM18000-0 18-point Input Expansion Module
Includes: MS/TP communication; 18 points (18 BI); 24VAC input

Note: XPM models that comply with Buy American Act requirements are available. To order the model
that complies with the Buy American Act requirements, add a G to the end of the product code. For
example, F4-XPM04060-0G.

Table 3: XPM series accessories (order separately)


Product Code Number Description
TL-CCT-0 Controller Configuration Tool (CCT) software
FX-FCP-0 Facility Explorer Equipment Controller Firmware Package Files required for CCT
TL-CWCVT-0 Communications converter that provides a temporary wireless connection
between a host device and equipment controllers that support the BACnet MS/TP
protocol.
WRZ Series Wireless Room Sensors Refer to the WRZ Series Wireless Room Sensors Product Bulletin (LIT-12011653) for
specific sensor model descriptions.
WRZ-7860-0 Receiver for One-to-One Wireless Room Sensing Systems - functions with WRZ
Series Sensors
Refer to the WRZ-7860 Receiver for One-to-One Wireless Room Sensing Product
Bulletin (LIT-12011640) for a list of available products.
WRZ-SST-120 Wireless System Survey Tool. For use with the lower power 10mW WRZ and
WRZ-7860 systems.
Refer to the WRZ-SST-120 Wireless Sensing System Tool Installation Guide
(24-10563-55) for usage instructions.
ZFR-HPSST-0 Wireless System Survey Tool. For use with the higher power WRG1830/ZFR183x
System and lower power WRZ Sensors (10mW). Refer to the ZFR-HPSST-0 Wireless
Sensing System Tool Installation Guide (Part No. 24-11461-00012) for usage
instructions.
WRG1830/ZFR183x Pro Series Wireless Field Bus For more information on products needed for wireless field bus installations and
System for a list of available products, refer to the WRG1830/FX-ZFR183x Pro Series Wireless
Field Bus System Catalog Page (LIT-1901153).
Y64T15-0 Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 92 VA, Foot Mount,
72.2 cm (30 in.), Primary Leads and 76.2 cm (30 in.) Secondary Leads, Class 2
Y65A13-0 Transformer, 120 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount (Y65AS),
20.32 cm (8 in.), Primary Leads and 76.2 cm (30 in.) Secondary Leads, Class 2

4 F4-XPM Expansion Modules Catalog Page

171
Table 3: XPM series accessories (order separately)
Product Code Number Description
Y65T31-0 Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Foot Mount
(Y65AR+), 20.32 cm (8 in.), Primary Leads and Secondary Screw Terminals, Class 2
Y65T42-0 Transformer, 120/208/240 VAC Primary to 24 VAC Secondary, 40 VA, Hub Mount
(Y65SP+), 20.32 cm (8 in.), Primary Leads and Secondary Screw Terminals, Class 2
ACC-TBKINOUT-0 Input and Output terminal block replacement kit for SNC, CG series, CV series,
CCM, and XPM products. Kit includes 5 of each 2, 3, and 4 position Input and
Output terminal blocks. 30 terminal blocks in total.
ACC-TBKPWFCSA-0 Power, FC Bus, and SA Bus terminal block replacement kit for SNC, CG series,
CV series, CCM, and XPM products. Kit includes 5 of each terminal block type. 15
terminal blocks in total.
MS-FIT100-0 The Field Inspection Tool or (FIT) is a portable handheld device with a user
interface that is used to test and troubleshoot the BACnet protocol MS/TP RS-485
communications bus that connects supervisory controllers and equipment
controllers to field point interfaces.
The FIT can be used to check out the wiring of the MS/TP RS-485 bus as well
as verify proper communications of supervisory controllers and equipment
controllers connected to the bus. The FIT can be used on both the FC Bus and SA
Bus.
TL-BRTRP-0 Portable BACnet/IP to MS/TP Router

XPM Expansion Modules technical specifications


Table 4: Technical specifications
Specification Description
Power requirement 24 VAC (nominal, 20 VAC minimum/30 VAC maximum), 50/60 Hz, Power Supply Class 2
(North America), Safety Extra-Low Voltage (SELV) (Europe)
Power consumption 14 VA maximum
Note: The VA rating does not include any power supplied to the peripheral devices
connected to Binary Outputs (BOs) or Configurable Outputs (COs), which can
consume up to 12 VA for each BO or CO; for a possible total consumption of an
additional 84 VA (maximum).
Power source +15 VDC power source terminals provide 100 mA total current.
Note: Only present on XPM09090 and XPM04060 models.
• F4-XPM09090-0: Quantity 2-located in Universal Input terminals for active (3-wire)
input devices.
• F4-XPM04060-0: Quantity 1-located in Universal Input terminals for active (3-wire)
input devices.
Ambient conditions Operating: 0°C to 50°C (32°F to 122°F); 10% to 90% RH noncondensing
Storage: -40°C to 80°C (-40°F to 176°F); 5% to 95% RH noncondensing
Communications protocol BACnet MS/TP; Zigbee Wireless also supported (at FC Bus and for Sensors) with additional
hardware.
XPM expansion modules support Zigbee wireless functionality for the FC bus and for
sensors with additional hardware.

5 F4-XPM Expansion Modules Catalog Page

172
Table 4: Technical specifications
Specification Description
Device addressing for BACnet MS/TP Decimal address set using the three rotary switches; valid controller device addresses
4-127
Communications bus RS-485
3-wire FC Bus between the supervisory controller and expansion modules
4-wire SA Bus between equipment controller, network sensors and other sensor/actuator
devices, includes a lead to source 15 VDC supply power (from equipment controller) to
bus devices.
Processor RX64M Renesas® 32-Bit microcontroller
Memory 16 MB flash memory and 8 MB SDRAM
Input and output capabilities Universal Inputs: Defined as 0–10 VDC, 4–20 mA, 0–600k ohms, or Binary Dry Contact
Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode
Configurable Outputs: Defined as 0-10 VDC or 24 VAC @500mA Triac BO
Analog Outputs: Defined as 0–10 VDC or 4–20 mA
Binary Outputs: Defined as 24 @500mA VAC Triac (external power source only)
Universal Input (UI) Resolution / Analog Input: 24-bit Analog to Digital converter
Output (AO) Accuracy Output: +/- 200 mV accuracy in 0–10 VDC applications
Terminations Input/Output: Pluggable Screw Terminal Blocks
SA/FC Bus and Supply Power: 4-Wire and 2-Wire Pluggable Screw Terminal Blocks
SA/FC Bus Port: RJ-12 6-Pin Modular Jack
Mounting Horizontal on single 35 mm DIN rail mount (recommended), or screw mount on flat
surface with three integral mounting clips on controller
Housing Enclosure material: ABS and polycarbonate UL94 5VB; Self-extinguishing
Protection Class: IP20 (IEC529)
Dimensions (height x width x depth) XPM09090-0: 150 mm x 190 mm x 44.5 mm (5-7/8 in. x 7-1/2 in. x 1-3/4 in.) including
terminals and mounting clips
XPM04060-0 and XPM18000-0: 150 mm x 152 mm x 44.5 mm (5-7/8 in. x 6 in. x 1-3/4 in.)
including terminals and mounting clips
Note: Mounting space requires an additional 50 mm (2 in.) space on top,
bottom, and front face of controller for easy cover removal, ventilation, and wire
terminations.
Weight XPM09090-0: 0.5 kg (1.1 lb)
XPM04060-0 and XPM18000-0: 0.29 kg (0.64 lb)
Compliance United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management
Equipment
FCC Compliant to CFR47, Part 15, Subpart B, Class A
Canada: UL Listed, File E107041, CCN PAZX7 CAN/CSA C22.2 No. 205, Signal Equipment
Industry Canada Compliant, ICES-003
Europe: Johnson Controls declares that this product is in compliance with the essential
requirements and other relevant provisions of the EMC Directive and RoHS Directive.
Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant

6 F4-XPM Expansion Modules Catalog Page

173
Table 4: Technical specifications
Specification Description
BACnet International: BACnet Testing Laboratories™ (BTL) Protocol Revision 18 Listed
and Certified BACnet Smart Actuator (B-SA), based on ANSI/ASHRAE 135-2020
United Kingdom: Johnson Controls declares that this product is in compliance with
Electromagnetic Compatibility Regulations, The Electrical Equipment (Safety) Regulations,
and Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic
Equipment Regulations.

The performance specifications are nominal and conform to acceptable industry standard. For application at
conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be
liable for damages resulting from misapplication or misuse of its products.

Repair information Contact information


If an expansion module fails to operate within its Contact your local Johnson Controls representative:
specifications, replace the expansion module. For www.johnsoncontrols.com/locations
a replacement expansion module, contact your Contact Johnson Controls:
Johnson Controls representative. www.johnsoncontrols.com/contact-us

Product warranty
This product is covered by a limited
warranty, details of which can be found at
www.johnsoncontrols.com/buildingswarranty.

Single point of contact


APAC EU UK NA/SA
JOHNSON JOHNSON JOHNSON JOHNSON
CONTROLS CONTROLS CONTROLS CONTROLS
C/O CONTROLS VOLTAWEG 20 TYCO PARK 5757 N GREEN
PRODUCT 6101 XK ECHT GRIMSHAW BAY AVE.
MANAGEMENT THE LANE GLENDALE, WI
NO. 32 NETHERLANDS MANCHESTER 53209
CHANGJIANG USA
M40 2WL
RD NEW
UNITED
DISTRICT
KINGDOM
WUXI JIANGSU
PROVINCE
214028
CHINA

7 F4-XPM Expansion Modules Catalog Page

174

You might also like