MULTIFUNCTION METERS
MFM384-C-CE * # $ 7287
85 to 270V AC, Class 1 (Class 0.5 option)
MFM376-C-CE $ 5246
40 to 270V DC & 85 to 270V AC
MFM391 New LED multifunction meter, Measures V, A ,F with Power and PF, 85 to 270V AC 1918
MFM SERIES
Note: * UL variant available # MID variant available $ Class 0.5s variant available Pricelist 2021 (w.e.f. May 20 , 2021)
th
www.selec.com Page 5
Save Time,
Save Money
PLUG-N-WIRE
MULTIFUNCTION METER
Rail mount LCD Plug-N-Wire multifunction meter with RJ45 current input,
MRJ4M-SL # 9020
Dual load monitoring and RS485 communication, 60 to 300V AC
90303390
Rail mount LCD Plug-N-Wire multifunction meter with RJ45 current input and
MRJ4M # 7473
RS485 communication, 60 to 300V AC
ACCESSORIES - PLUG-N-WIRE
POWER & COMMUNICATION CABLE
PWCON-F Plug-N-Wire connector Female type 143
PWCBL_CON-F-1 Plug-N-Wire Power cable with Female type connector, 1 Meter length 424
PWCBL_CON-F-3 Plug-N-Wire Power cable with Female type connector, 3 Meter length 885
85444299
PWCBL_CON-M/F-1 Plug-N-Wire Daisy chain cable with Male & Female type connectors, 1 Meter length 586
PWCBL_CON-M/F-3 Plug-N-Wire Daisy chain cable with Male & Female type connectors, 3 Meter length 1074
ACH-004 Cable to connect MRJ Meter with PWCT/PLCT – RJ45 to RJ45 (8Pin) 443
PLUG-N-WIRE
CTV CONVERTER 1A/330 mV Converter used with PLCT series 85043100 1109
Note: * UL variant available # MID variant available $ Class 0.5s variant available Pricelist 2021 (w.e.f. May 20 , 2021)
th
www.selec.com Page 6
Product Code Description HSN Code Unit MRP
PLCT 21/25 100 /1A VA 1 CL 3 100A Plug-N-Wire CT - To be used wth CTV Converter 1217
PLCT 21/25 125 /1A VA 1.5 CL 1 125A Plug-N-Wire CT - To be used wth CTV Converter 1263
PLCT 21/25 150 /1A VA 2.5 CL 0.5 150A Plug-N-Wire CT - To be used wth CTV Converter 1300
PLCT 21/25 160 /1A VA 2.5 CL 0.5 160A Plug-N-Wire CT - To be used wth CTV Converter 1325
PLCT 21/25 200 /1A VA 3 CL 0.5 200A Plug-N-Wire CT - To be used wth CTV Converter 1417
PLCT 21/25 250 /1A VA 3 CL 0.5 250A Plug-N-Wire CT - To be used wth CTV Converter 1537
www.selec.com Page 7
ENERGY METERS
3Ø Direct 100A kWh meter, Self powered, 85 to 285V AC (L-N), 154 to 494V AC (L-L)
EM4M-3P-C-100A New 90303390 7692
with RS485 communication
EM2M-1P-C-100A # 1Ø Direct 100A kWh meter, Self powered, 184 to 276V AC with RS485 communication 3271
www.selec.com Page 8
SELCOM
PRICE ON
REQUEST
Energy Monitoring
Monitor &
Control
Energy Analytics
Management
Device 1 Device 2
Dashboards Alarms
Configure
Local Monitoring
Control
Connect
Installed At:
Cement Industries
Education Institutes (Universities)
Defence Sectors
FMCG Companies
Textile & Automobile Industries
Food Processing Industries
New
LC
OM OM
FREE PC based software for
E
S IT E LC
L
SE ITE
L monitoring 6 slave devices
on USB port.
COMMUNICATION GATEWAYS
AC-S2E-02 New Converter – RS485 to Ethernet 5345
www.selec.com Page 9
DIGITAL PANEL
METERS
VAF39A-1-230V Digital VAF meter with LED display, Built in RPM / RUN hour measurement, 230V AC 2040
MVA593-CE New Three phase VA meter up to 800A current measurement using external CT, CE certified 1505
New Single Phase Multifunction Digital panel meter with 1 alarm relay output and
MX300-1-C-CE 90303310 2078
RS485 MODBUS communication
New Single Phase Multifunction Digital panel meter with universal auxiliary supply
MX300-CE 1408
of 85 to 300V AC/DC
MVA591-80A-230V New Single phase VA meter with measurement up to 80A with built in CT 1192
MVA591-30A-230V New Single phase VA meter with measurement up to 30A with built in CT 1148
www.selec.com Page 10
DIGITAL PANEL METER - VOLTMETER
Class 0.5 accuracy
True RMS voltage measurement
Available in LCD and LED display
Analog style bar graph model available
PT programmable (For three phase variant)
CE & RoHS certified
MV507-230V-CE 1Ø Digital voltmeter with LCD display, Bar graph representation for voltage, 230V AC 1390
90303310
MV15 1Ø Digital voltmeter with LED display, 230V AC 845
MA12-75mV-DC 1Ø Digital ammeter with LED display, 75mV DC shunt input, 230V AC 1662
MA12-20A-AC 1Ø Digital ammeter with LED display, 20A direct input, 230V AC 1503
90303310
MA501-230V-CE 1Ø Digital ammeter with LCD display, Bar graph representation for current, 230V AC 1468
www.selec.com Page 11
ANALOG METERS
www.selec.com Page 12
Product Code Description HSN Code Unit MRP
AM-I-D-2-80A Analog ammeter, Class 1.5, 80A AC direct input 653
AM-PF-2-3P1E-0.5 CAP-1-0.5 IND-415V-5A Analog power factor meter, Class 1.5, 0.5 CAP - 0.5 IND, 415V AC, 72 x 72mm 956
90303310
AM-PF-3-3P1E-0.5 CAP-1-0.5 IND-440V-5A Analog power factor meter, Class 1.5, 0.5 CAP - 0.5 IND, 440V, 96 x 96mm 995
AM-PF-2-3P1E-0.5 CAP-1-0.5 IND-440V-5A Analog power factor meter, Class 1.5, 0.5 CAP - 0.5 IND, 440V, 72 x 72mm 956
TC-3 Terminal cover for 96 x 96 Analog meter Ammeter / Voltmeter / Direct type up to 30A 52
39269099
TC-D-2 Terminal cover for 72 x 72 Analog meter for Direct type Ammeter above 30A 52
TC-D-3 Terminal cover for 96 x 96 Analog meter for Direct type Ammeter above 30A 55
ANALOG METERS
www.selec.com Page 13
CURRENT
TRANSFORMERS
New
SCCT 30/20 100/5A VA 1.5 CL 3 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 100/5A, Accuracy class 1.5 2352
SCCT 30/20 150/5A VA 1 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 150/5A, Accuracy class 0.5 2352
SCCT 30/20 150/5A VA 1.5 CL 3 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 150/5A, Accuracy class 3 2352
SCCT 30/20 200/5A VA 1 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 200/5A, Accuracy class 0.5 2352
SCCT 30/20 200/5A VA 1.5 CL 1 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 200/5A, Accuracy class 1 2352
SCCT 30/20 200/5A VA 2.5 CL 3 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 200/5A, Accuracy class 3 2352
SCCT 30/20 250/5A VA 1.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 250/5A,Accuracy class 0.5 2352
SCCT 30/20 250/5A VA 2 CL 1 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 250/5A, Accuracy class 1 2352
SCCT 30/20 250/5A VA 3.75 CL 3 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 250/5A, Accuracy class 3 2352
SCCT 30/20 300/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 300/5A, Accuracy class 0.5 2352
SCCT 30/20 300/5A VA 3.75 CL 1 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 250/5A, Accuracy class 1 2352
85043100
SCCT 30/20 300/5A VA 5 CL 3 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 250/5A, Accuracy class 3 2352
SCCT 30/20 400/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 400/5A, Accuracy class 0.5 2352
SCCT 30/20 400/5A VA 5 CL 1 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 400/5A, Accuracy class 1 2352
SCCT 30/20 400/5A VA 10 CL 3 -CE Split core Current transformer. Inner Dimensions: 30/20, Rating: 400/5A, Accuracy class 3 2352
SCCT 80/50 250/5A VA1 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 250/5A, Accuracy class 0.5 2868
SCCT 80/50 250/5A VA 2 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 250/5A, Accuracy class 1 2868
CURRENT TRANSFORMERS
SCCT 80/50 250/5A VA 3.75 CL 3 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 250/5A, Accuracy class 3.75 2868
SCCT 80/50 300/5A VA1.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 300/5A, Accuracy class 0.5 2868
SCCT 80/50 300/5A VA 3 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 300/5A, Accuracy class 1 2868
SCCT 80/50 300/5A VA 5 CL 3 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 300/5A, Accuracy class 3 2868
SCCT 80/50 400/5A VA1.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 400/5A, Accuracy class 0.5 2868
SCCT 80/50 400/5A VA 3 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 400/5A, Accuracy class 1 2868
www.selec.com Page 14
Product Code Description HSN Code Unit MRP
SCCT 80/50 400/5A VA 10 CL 3 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 400/5A, Accuracy class 3 2868
SCCT 80/50 500/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 500/5A, Accuracy class 0.5 2868
SCCT 80/50 500/5A VA 5 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 500/5A, Accuracy class 1 2868
SCCT 80/50 500/5A VA 15 CL 3 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 500/5A, Accuracy class 3 2868
SCCT 80/50 600/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 600/5A, Accuracy class 0.5 2868
SCCT 80/50 600/5A VA 5 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 600/5A, Accuracy class 1 2868
SCCT 80/50 600/5A VA 15 CL 3 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 600/5A, Accuracy class 3 2868
SCCT 80/50 750/5A VA 3 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 750/5A, Accuracy class 0.5 2868
SCCT 80/50 750/5A VA 7.5 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 750/5A, Accuracy class 1 2868
SCCT 80/50 750/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 750/5A, Accuracy class 3 2868
SCCT 80/50 800/5A VA 3 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 800/5A, Accuracy class 0.5 2868
SCCT 80/50 800/5A VA 7.5 CL 1-CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 800/5A, Accuracy class 1 2868
SCCT 80/50 800/5A VA 20 CL 3-CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 800/5A, Accuracy class 3 2868
SCCT 80/50 1000/5A VA 5 CL 0.5-CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 1000/5A, Accuracy class 0.5 2868
SCCT 80/50 1000/5A VA 10 CL 1-CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 1000/5A, Accuracy class 1 2868
SCCT 80/50 1000/5A VA 20 CL 3-CE Split core Current transformer. Inner Dimensions: 80/50, Rating: 1000/5A, Accuracy class 3 2868
SCCT 80/80 250/5 A VA 1.5 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 250/5A, Accuracy class 1 3476
SCCT 80/80 300/5 A VA 1.5 CL 1 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 250/5A, Accuracy class 1 3476
SCCT 80/80 400/5 A VA 1.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 400/5A, Accuracy class 0.5 3476
SCCT 80/80 500/5 A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 500/5A, Accuracy class 0.5 3476
SCCT 80/80 600/5 A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 600/5A, Accuracy class 0.5 3476
SCCT 80/80 750/5 A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 750/5A, Accuracy class 0.5 3476
SCCT 80/80 800/5 A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 800/5A, Accuracy class 0.5 3476
SCCT 80/80 1000/5 A VA 5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 1000/5A, Accuracy class 1 3476
SCCT 120/80 500/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 500/5A, Accuracy class 0.5 85043100 4795
SCCT 120/80 500/5A VA 3.75 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 500/5A, Accuracy class 1 4795
SCCT 120/80 500/5A VA 15 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 500/5A, Accuracy class 3 4795
SCCT 120/80 600/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 600/5A, Accuracy class 0.5 4795
SCCT 120/80 600/5A VA 5 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 600/5A, Accuracy class 1 4795
SCCT 120/80 600/5A VA 15 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 600/5A, Accuracy class 3 4795
SCCT 120/80 750/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 750/5A, Accuracy class 0.5 4795
SCCT 120/80 750/5A VA 2.5 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 750/5A, Accuracy class 1 4795
SCCT 120/80 750/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 750/5A, Accuracy class 3 4795
SCCT 120/80 800/5A VA 2.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 80/80, Rating: 800/5A, Accuracy class 0.5 4795
SCCT 120/80 800/5A VA 7.5 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 800/5A, Accuracy class 1 4795
SCCT 120/80 800/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 800/5A, Accuracy class 3 4795
SCCT 120/80 1000/5A VA 5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1000/5A, Accuracy class 0.5 4795
SCCT 120/80 1000/5A VA 10 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1000/5A, Accuracy class 1 4795
SCCT 120/80 1000/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1000/5A, Accuracy class 3 4795
SCCT 120/80 1200/5A VA 7.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1200/5A, Accuracy class 0.5 4795
SCCT 120/80 1200/5A VA 15 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1200/5A, Accuracy class 1 4795
SCCT 120/80 1200/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1200/5A, Accuracy class 3 4795
CURRENT TRANSFORMERS
SCCT 120/80 1250/5A VA 7.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1250/5A, Accuracy class 0.5 4795
SCCT 120/80 1250/5A VA 15 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1250/5A, Accuracy class 1 4795
SCCT 120/80 1250/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1250/5A, Accuracy class 3 4795
SCCT 120/80 1500/5A VA 7.5 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1500/5A, Accuracy class 0.5 4795
SCCT 120/80 1500/5A VA 10 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1500/5A, Accuracy class 1 4795
SCCT 120/80 1500/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1500/5A, Accuracy class 3 4795
SCCT 120/80 1600/5A VA 10 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 800/5A, Accuracy class 0.5 4795
www.selec.com Page 15
Product Code Description HSN Code Unit MRP
SCCT 120/80 1600/5A VA 20 CL 1 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1600/5A, Accuracy class 1 4795
SCCT 120/80 1600/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 120/80, Rating: 1600/5A, Accuracy class 3 4795
SCCT 160/80 1000/5A VA10 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1000/5A, Accuracy class 0.5 7898
SCCT 160/80 1000/5A VA 15 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1000/5A, Accuracy class 1 7898
SCCT 160/80 1000/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1000/5A, Accuracy class 3 7898
SCCT 160/80 1200/5 A VA 10 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1200/5A, Accuracy class 0.5 7898
SCCT 160/80 1250/5A VA10 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1250/5A, Accuracy class 0.5 7898
SCCT 160/80 1250/5A VA 15 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1250/5A, Accuracy class 1 7898
SCCT 160/80 1250/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1250/5A, Accuracy class 31 7898
SCCT 160/80 1500/5A VA15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1500/5A, Accuracy class 0.5 7898
SCCT 160/80 1500/5A VA 20 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1500/5A, Accuracy class 1 7898
SCCT 160/80 1500/5A VA 20 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 1500/5A, Accuracy class 3 7898
SCCT 160/80 2000/5A VA15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 2000/5A, Accuracy class 0.5 7898
SCCT 160/80 2000/5A VA 20 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 2000/5A, Accuracy class 1 7898
SCCT 160/80 2000/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 2000/5A, Accuracy class 3 7898
85043100
SCCT 160/80 2500/5A VA15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 2500/5A, Accuracy class 0.5 7898
SCCT 160/80 2500/5A VA 20 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 2500/5A, Accuracy class 1 7898
SCCT 160/80 2500/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 2500/5A, Accuracy class 3 7898
SCCT 160/80 3000/5A VA 15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 3000/5A, Accuracy class 0.5 7898
SCCT 160/80 3000/5A VA 30 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 3000/5A, Accuracy class 1 7898
SCCT 160/80 3000/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 3000/5A, Accuracy class 3 7898
SCCT 160/80 4000/5A VA 15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 4000/5A, Accuracy class 0.5 7898
SCCT 160/80 4000/5A VA 30 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 4000/5A, Accuracy class 1 7898
SCCT 160/80 4000/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 4000/5A, Accuracy class 3 7898
SCCT 160/80 5000/5A VA 15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 5000/5A, Accuracy class 0.5 7898
SCCT 160/80 5000/5A VA 30 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 5000/5A, Accuracy class 1 7898
SCCT 160/80 5000/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 5000/5A, Accuracy class 3 7898
SCCT 160/80 6000/5A VA 15 CL 0.5 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 6000/5A, Accuracy class 0.5 7898
SCCT 160/80 6000/5A VA 30 CL 1 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 6000/5A, Accuracy class 1 7898
SCCT 160/80 6000/5A VA 30 CL 3 -CE Split core Current transformer. Inner Dimensions: 160/80, Rating: 6000/5A, Accuracy class 3 7898
SPCT 50/ 30 60/5 A VA 1 CL 5 * Bus bar CT with 60/5A, OD/ID: 50/30 325
SPCT 50/30 75/5A VA 1 CL 1 * Bus bar CT with 75/5A, OD/ID: 50/30 325
85043100
SPCT 50/30 80/5A VA 1 CL 1 * Bus bar CT with 80/5A, OD/ID: 50/30 325
SPCT 50/30 100/5A VA 1 CL 1 * Bus bar CT with 100/5A, OD/ID: 50/30 325
www.selec.com Page 16
Product Code Description HSN Code Unit MRP
SPCT 50/30 125/5A VA 1.25 CL 1 * Bus bar CT with 125/5A, OD/ID: 50/30 325
SPCT 50/30 160/5A VA 1.5 CL 1 * Bus bar CT with 160/5A, OD/ID: 50/30 325
SPCT 50/30 200/5A VA 3 CL 1 * Bus bar CT with 200/5A, OD/ID: 50/30 325
SPCT 50/30 250/5A VA 3 CL 1 * Bus bar CT with 250/5A, OD/ID: 50/30 338
SPCT 50/30 300/5A VA 5 CL 1 * Bus bar CT with 300/5A, OD/ID: 50/30 389
SPCT 50/30 400/5A VA 5 CL 1 * Bus bar CT with 400/5A, OD/ID: 50/30 389
SPCT 62/ 22 30/5 A VA 1 CL 5 * Bus bar CT with 30/5A, OD/ID: 62/22 584
SPCT 62/ 30 50/5 A VA 1 CL 3 * Bus bar CT with 50/5A, OD/ID: 62/30 522
SPCT 62/ 30 50/5 A VA 1.5 CL 3 * Bus bar CT with 50/5A, OD/ID: 62/30 522
SPCT 62/ 30 75/5 A VA 1 CL 3 * Bus bar CT with 75/5A, OD/ID: 62/30 522
SPCT 62/ 30 75/5 A VA 3 CL 3 * Bus bar CT with 75/5A, OD/ID: 62/30 540
SPCT 62/ 30 100/5 A VA 1 CL 1 * Bus bar CT with 100/5A, OD/ID: 62/30 540
SPCT 62/ 30 100/5 A VA 3 CL 1 * Bus bar CT with 100/5A, OD/ID: 62/30 543
SPCT 62/ 40 100/5 A VA 1 CL 1 * Bus bar CT with 100/5A, OD/ID: 62/40 384
SPCT 62/ 40 125/5 A VA 1 CL 1 * Bus bar CT with 125/5A, OD/ID: 62/40 384
SPCT 62/ 40 150/5 A VA 1.5 CL 1 * Bus bar CT with 150/5A, OD/ID: 62/40 384
SPCT 62/ 40 150/5 A VA 3 CL 1 * Bus bar CT with 150/5A, OD/ID: 62/40 463
SPCT 62/ 40 160/5 A VA 1.5 CL 1 * Bus bar CT with 160/5A, OD/ID: 62/40 384
SPCT 62/ 40 200/5 A VA 2.5 CL 0.5 * Bus bar CT with 200/5A, OD/ID: 62/40 384
SPCT 62/ 40 200/5 A VA 3 CL 1 * Bus bar CT with 200/5A, OD/ID: 62/40 424
SPCT 62/ 40 250/5 A VA 2.5 CL 0.5 * Bus bar CT with 250/5A, OD/ID: 62/40 384
85043100
SPCT 62/ 40 250/5 A VA 3 CL 1 * Bus bar CT with 250/5A, OD/ID: 62/40 384
SPCT 62/ 40 300/5 A VA 3 CL 0.5 * Bus bar CT with 300/5A, OD/ID: 62/40 384
SPCT 62/ 40 400/5 A VA 3.75 CL 0.5 * Bus bar CT with 400/5A, OD/ID: 62/40 410
SPCT 62/ 40 400/5 A VA 5 CL 1 * Bus bar CT with 400/5A, OD/ID: 62/40 410
SPCT 100/ 60 500/5 A VA 5 CL 1 * Bus bar CT with 500/5A, OD/ID: 100/60 779
SPCT 100/ 60 600/5 A VA 5 CL 0.5 * Bus bar CT with 600/5A, OD/ID: 100/60 779
SPCT 100/ 60 600/5 A VA 7.5 CL 1 * Bus bar CT with 600/5A, OD/ID: 100/60 779
SPCT 100/ 60 800/5 A VA 10 CL 0.5 * Bus bar CT with 800/5A, OD/ID: 100/60 844
SPCT 100/ 60 1000/5 A VA 15 CL 0.5 * Bus bar CT with 1000/5A, OD/ID: 100/60 961
SPCT 100/ 60 1200/5 A VA 15 CL 0.5 * Bus bar CT with 1200/5A, OD/ID: 100/60 1064
SPCT 140/100 800/5 A VA 15 CL 0.5 Bus bar CT with 800/5A, OD/ID: 140/100 1077
SPCT 140/ 100 1000/5 A VA 15 CL 0.5 Bus bar CT with 1000/5A, OD/ID: 140/100 1140
SPCT 140/ 100 1200/5 A VA 15 CL 0.5 Bus bar CT with 1200/5A, OD/ID: 140/100 1192
SPCT 140/ 100 1250/5 A VA 15 CL 0.5 Bus bar CT with 1250/5A, OD/ID: 140/100 1192
SPCT 140/ 100 1500/5 A VA 15 CL 0.5 Bus bar CT with 1500/5A, OD/ID: 140/100 1288
SPCT 140/ 100 1600/5 A VA 15 CL 0.5 Bus bar CT with 1600/5A, OD/ID: 140/100 1316
SPCT 140/ 100 2000/5 A VA 15 CL 0.5 Bus bar CT with 2000/5A, OD/ID: 140/100 1449
SPCT 140/ 100 2500/5 A VA 15 CL 0.5 Bus bar CT with 2500/5A, OD/ID: 140/100 1578
SPCT 140/ 100 3000/5 A VA 15 CL 0.5 Bus bar CT with 3000/5A, OD/ID: 140/100 1765
CURRENT TRANSFORMERS
SPCT 140/ 100 3500/5 A VA 15 CL 0.5 Bus bar CT with 3500/5A, OD/ID: 140/100 1898
SPCT 140/ 100 4000/5 A VA 15 CL 0.5 Bus bar CT with 4000/5A, OD/ID: 140/100 2056
www.selec.com Page 17
CURRENT TRANSFORMER - CABLE TYPE
Availabale range: 30A - 600A
Rated Burden: 1.5 /5VA
Accuracy: Class 1 to 5
Panel mount
RCT-T-D30-30/5 A VA 5 (2T) CL5 Ring type CT with 30/5A, Inner diameter - 30mm 546
RCT-T-D30-50/5 A VA 5 CL5 Ring type CT with 50/5A, Inner diameter - 30mm 544
RCT-T-D30-75/5 A VA 5 CL5 Ring type CT with 75/5A, Inner diameter - 30mm 545
RCT-T-D30-100/5 A VA 5 CL1 Ring type CT with 100/5A, Inner diameter - 30mm 545
RCT-T-D30-150/5 A VA 5 CL1 Ring type CT with 150/5A, Inner diameter - 30mm 587
85043100
RCT-T-D50-200/5 A VA 5 CL1 Ring type CT with 200/5A, Inner diameter - 50mm 587
RCT-T-D50-250/5 A VA 5 CL1 Ring type CT with 250/5A, Inner diameter - 50mm 587
RCT-T-D50-300/5 A VA 5 CL1 Ring type CT with 300/5A, Inner diameter - 50mm 587
RCT-T-D50-400/5 A VA 5 CL1 Ring type CT with 400/5A, Inner diameter - 50mm 561
RCT-T-D50-500/5 A VA 5 CL1 Ring type CT with 500/5A, Inner diameter - 50mm 587
RCT-T-D50-600/5 A VA 5 CL1 Ring type CT with 600/5A, Inner diameter - 50mm 587
TWCT-T-D35 50/5A VA 5 CL 5 Ring type CT with 30/5A, Inner diameter - 30mm 467
TWCT-T-D35 75/5A VA 5 CL 5 Ring type CT with 50/5A, Inner diameter - 30mm 393
TWCT-T-D35 100/5A VA 5 CL 1 Ring type CT with 75/5A, Inner diameter - 30mm 550
TWCT-T-D35 150/5A VA 5 CL 1 Ring type CT with 100/5A, Inner diameter - 30mm 440
TWCT-T-D55 150/5A VA 5 CL 1 Ring type CT with 150/5A, Inner diameter - 30mm 475
TWCT-T-D55 200/5A VA 5 CL 1 Ring type CT with 200/5A, Inner diameter - 50mm 419
TWCT-T-D55 250/5A VA 5 CL 1 Ring type CT with 250/5A, Inner diameter - 50mm 424
TWCT-T-D55 300/5A VA 5 CL 1 Ring type CT with 300/5A, Inner diameter - 50mm 85043100 445
TWCT-T-D55 400/5A VA 5 CL 1 Ring type CT with 400/5A, Inner diameter - 50mm 463
TWCT-T-D65 500/5A VA 5 CL 1 Ring type CT with 500/5A, Inner diameter - 50mm 440
CURRENT TRANSFORMERS
TWCT-T-D65 600/5A VA 5 CL 1 Ring type CT with 600/5A, Inner diameter - 50mm 472
TWCT-T-D110 800/5A VA 10 CL 0.5 Tape wound CT with 800/5A, Inner diameter - 110mm 711
TWCT-T-D110 1000/5A VA 10 CL 0.5 Tape wound CT with 1000/5A, Inner diameter - 110mm 786
TWCT-T-D120 1000/5A VA 10 CL 0.5 Tape wound CT with 1000/5A, Inner diameter - 120mm 607
TWCT-T-D120 1200 /5A VA 10 CL 0.5 Tape wound CT with 1200/5A, Inner diameter - 120mm 671
TWCT-T-D120 1600 /5A VA 10 CL 0.5 Tape wound CT with 1600/5A, Inner diameter - 120mm 795
www.selec.com Page 18
AUTOMATIC POWER
FACTOR CONTROLLERS
APFC146-112-90/550V-CE New Power factor controller with 1CT, 12 Stage, LCD Display, 90 to 550V AC 7853
APFC346-108-230V-CE New Power factor controller with 1CT, 8 Stage, LCD Display, 85 to 270V AC 5711
90328910
APFC147-112-90/550V Power factor controller with 1CT, 12 Stage, LED Display, 90 to 550V AC 8817
APFC147-108-90/550V Power factor controller with 1CT, 8 Stage, LED Display, 90 to 550V AC 7651
APFC347-108-230V Power factor controller with 1CT, 8 Stage, LED Display, 85 to 270V AC 5711
www.selec.com Page 19
CAPACITORS
New
HEAVY DUTY CAPACITORS
Fast discharge resistors
Over pressure disconnection system (Only above 10KVAR)
Internal fuse for protection
Polyurethane self-extinguishing resin V0, developed under standard UL94
DRY type
CE & RoHS certified
www.selec.com Page 20
LINE MONITORING SERIES
3Ø-3W, 3Ø-4W, Under / Over voltage, Phase failure, Phase sequence, Phase asymmetry,
900VPR-2-280/600V-CE New 2448
Under / Over frequency, Neutral loss, 2 x 1 C/O, Self powered
85363000
3Ø-3W, 3Ø-4W, Under / Over voltage, Phase failure, Phase sequence, Phase asymmetry,
900VPR-2-280/520V * 2355
Under / Over frequency, 2 x 1 C/O, Self powered
Digital, 1Ø-2W, 3Ø-4W, Under / Over voltage, Phase failure, Phase sequence, Phase asymmetry,
VPRD2M-BL-CE 2191
Under / Over frequency, With Backlight, 2 C/O DPDT
600VPR-310/520-CE 3Ø-3W, Under / Over voltage, Phase failure, Phase sequence, 1C/O 1864
85363000
600VPR-1-130/320-CE-RoHS New Single Phase Voltage Protection Relay 1462
800VPR-3 3Ø-3W, Under / Over voltage, Phase failure, Phase sequence, 1 C/O 1200
642PSR 3Ø-3W, Phase failure, Phase sequence, Phase asymmetry, DIN rail & Wall mount, 1 C/O 85363000 1047
800PSR 3Ø-3W, Phase failure, Phase sequence, Phase asymmetry, 1 C/O 729
AUTO SWITCH
Auto switch-313/457V New Single phase preventer with under and over voltage protection with user selectable modes 1095
LINE MONITORING
85363000
Auto switch-195/400V New Single phase preventer with under and over voltage protection with user selectable modes 1095
www.selec.com Page 21
CURRENT MONITORING
SERIES
900CPR-3-230V 1Ø & 3Ø, Over / Under current monitoring, Current asymmetry, 1 C/O, 230V AC 85363000 2889
ELR-341-1 Panel Mount ELR, Leakage Current range: 30mA to 30A, 85 to 270 V AC/DC 85363000 2916
ELRA2M2-1-230V-CE Analog earth leakage relay, Leakage current range: 30mA to 30A , 1 C/O, 230V AC 85364900 1979
CURRENT MONITORING
ELCTR35-1-30mA-230V Earth leakage relay with inbuilt CBCT Leakage current fixed: 30mA, 1 C/O, 230V AC 1576
85363000
ELCTR35-1-300mA-230V Earth leakage relay with inbuilt CBCT, Leakage current fixed: 300mA, 1 C/O, 230V AC 1576
600ELR-1-30mA/500mA New Analog earth leakage relay, Leakage current range: 30mA to 500mA, 1 C/O, 230V AC, 1M size 85364900 1425
www.selec.com Page 22
Product Code Description HSN Code Unit MRP
CBCT-120-1-CE Core balance current transformer with Dia 120mm 85364900 3287
EFCT 180/35 630 /1A VA1 CL1 Earth fault Current Transformer 630A Window Size: 180x35 mm 1460
EFCT 180/35 250 /1A VA1 CL1 Earth fault Current Transformer 250A, Window Size: 180x 35 mm 1259
85043100
EFCT 140/35 160/1A VA1 CL1 Earth fault Current Transformer 160A, Window Size: 140x 35 mm 1204
EFCT 140/35 250/1A VA1 CL1 Earth fault Current Transformer 250A, Window Size: 140x35 mm 1154
EFCT 100/25 160/1A VA1 CL1 Earth fault Current Transformer 160A, Window Size: 100x25 mm 826
EARTH FAULT
www.selec.com Page 23
MOTOR & PUMP
PROTECTION RELAYS
www.selec.com Page 24
TIME SWITCH &
ANALOG TIMERS
TS2M1-2-16A-230V-CE DIN Rail - daily / weekly time switch, Dual Channel, 2 X 1 C/O SPDT, 230V AC 2466
91070000
TS2M1-1-16A-230V V2 DIN Rail - daily / weekly time switch, 1 C/O, 230V AC 1700
www.selec.com Page 25
TIME RELAYS
Single & Multifunction timers available
Wide setting ranges
Universal power supply
Precise time setting
Panel or DIN rail mount
600XU-A-1-CU Multi function timer, 0.1 sec to 3 hr, 1 C/O,20 to 240V AC & 12 to 240V DC, UL certified 1441
600ST * Single function timer, 0.1 sec to 3 hr, 1 C/O, 240V AC 1036
642SQ-A Timer with On delay / Interval modes, 0sec to 60mins, 1 C/O,230V AC & 24V DC 829
800XU * Timer with On delay / Interval modes, 1sec to 30hr, 2 C/O, 20 to 240V AC & 12 to 240V DC 1455
800SD-2-110 Star Delta timer, Run time: 30 / 60sec, Change over: 50 / 100ms, 2 C/O, 110V AC 1239
800SD-2-415 Star Delta timer, Run time: 30 / 60sec, Change over: 50 / 100ms, 2 C/O, 230 to 450V AC 85364900 1182
800XA Timer with On delay / Interval modes, 3sec to 60mins, 2 C/O, 20 to 240V AC & 12 to 240V DC 1117
800SD-2-230 Star Delta timer, Run time: 30 / 60sec, Change over: 50 / 100ms, 2 C/O, 230V AC 1042
800SQ-A Timer with On delay / Interval modes, 3sec to 60mins, 1 C/O, 230V AC & 24V AC / DC 829
55XC-T8 * Panel mount timer with cyclic function, 1sec to 10hr, 2 C/O, 20 to 240V AC & 12 to 240V DC 1727
Plug in timer with On delay / Interval modes, 1sec to 10hr, 2 C/O, 20 to 240V AC &
55XU-P * 1608
12 to 240V DC
Panel mount timer with On delay / Interval modes, 1sec to 30hr, 2 C/O, 20 to 240V AC &
55XU-T * 1608
12 to 240V DC 85364900
55Q(V1.1)-P8-230 Plug in timer with On Delay / Interval Timer, 0sec to 60min, 230V AC 1182
55Q(V1.1)-T8-230 Panel mounted On Delay / Interval Timer, 0sec to 60min, 230V AC 1182
55ES-P8-230 Plug in timer with On delay / Interval modes, 3sec to 60min, 1 C/O, 230V AC & 24V AC / DC 934
55ES-T-230 Panel mount timer with On delay / Interval modes, 3sec to 60min, 1 C/O, 230V AC & 24V AC / DC 934
ALARM ANNUNCIATOR
8 Windows, 6 colours
MODBUS RS485 MODBUS RTU serial communication
90 to 270VAC aux supply
Selectable fault detection NO/NC sensing
Programmable individual window
Relay contacts for trip & buzzer
WINDOWS
TIME RELAYS
www.selec.com Page 26
Notes
INDEX
Note: Product photographs shown are for representative purposes only. Pricelist 2021 (w.e.f. May 20 , 2021)
th
www.selec.com
Selec GmbH
Selec USA
Selec Australia