0% found this document useful (0 votes)
5 views2 pages

SP63DS Célula de Carga

The SP63 Digital Aluminum Single Point Load Cell has a capacity of 100kg and is designed for various weighing systems including conveyors and scales, featuring an IP67 protection class. It offers high accuracy with a combined error of ≤±0.017% FS and an internal AD conversion rate of 1200 upd/sec. The load cell can be supplied with calibration certificates and includes options for adjustable digital low pass filters and various communication protocols.

Uploaded by

EDGAR BARBOSA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views2 pages

SP63DS Célula de Carga

The SP63 Digital Aluminum Single Point Load Cell has a capacity of 100kg and is designed for various weighing systems including conveyors and scales, featuring an IP67 protection class. It offers high accuracy with a combined error of ≤±0.017% FS and an internal AD conversion rate of 1200 upd/sec. The load cell can be supplied with calibration certificates and includes options for adjustable digital low pass filters and various communication protocols.

Uploaded by

EDGAR BARBOSA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

digital single point

SP63
4053D
Digital Aluminum Single
point load cell. For use in
Conveyor weighing systems,
Tank Bin and hopper Weigh
Systems, Bench Scales and
Floor Scales. Protection class
IP67.
IP67

FEATURES OUTLINE DIMENSIONS


• Capacity 100kg.
6.85
• High grade aluminum construction. [174.0]
BLACK HEAT
SHRINK TUBE
• Environmental protection IP67.
• AD conversion rate up to 2.36
1200upd./sec. [60.0]

1.69
0.51
[43.0],(X4)
[13.0]

APPLICATIONS
• Conveyor weighing systems, 2.56
[65.0]
Tank Bin and hopper Weigh
Systems, Bench Scales and
Floor Scales.

4.802 0.28
[122.00] [7.0]

OPTIONS 1.181
[30.00]
• Load cells can be supplied with
calibration certificates as per ASTM
E74. 0.59 M8X1.25,
[15.0] 0.748
0.79[20.0]DP, [19.00],(X2)
(X8)

Group Four Transducers


22 Deer Park Drive, Phone : (800) 419 1444
E. Longmeadow, MA 01028 Fax : (413) 525 -6182
www.groupfourtransducers.com [email protected]

Page 1 of 2
digital single point
SP63 SPECIFICATIONS
Model SP63

4053D Capacities (E max)


PERFORMANCES
kg 100

Accuracy class according to OIML R60 C3


Combined Error %FS ≤±0.017
Creep @ 30min %FS ≤±0.017

Zero Balance, raw counts increments ±2000

Output resolution at full load, raw counts increments 512000


Internal AD conversion rate upd./sec 1200
18 (Supress 50Hz and 60Hz
Fix, Digital Low Pass IIR Filter, Default Hz
Influence)
Adjustable , Digital Low Pass IIR Filter 18-0.25; Selectable in 8 Steps
Adjustable , Digital Low Pass FIR Filter Hz
40-5; Selectable in 8 Steps

WIRING Adjustable, External Output Update Rate upd./sec 1200-9; Selectable in 8 Steps
GENERAL I/O’s
Pin No. Connection Cable Color
Hardware Interface, RS Version RS232
2 TxD Green
Data transm. rates RS232 kb 9.6;19.2;38.4;57.6;115.2;230.4;460.8
3 RxD White
Protocol RS232 ASCII or Modbus RTU
4 GND1 Black
Logical Input, Programmable Trigger Level 2 -30Vdc,<3mA,Ref to Gnd.
8 PWR+ Red
Power supply VDC 10-30 ≤ 0.4 Watt
INFLUENCES
PIN CONFIGURATION OF
Safe Load Limit %* Emax 150
DB9 MALE CONNECTOR
Ultimate Load %* Emax 200
Eccentric loading error acc. to OIML R76 %FS ≤±0.023
5- Max platform size
4-
-9 mm 400X600
-8
3- Temperature Effect on Zero %FS/°C 0.004
FCI

-7
2-
-6
1- Temperature Effect on Span %FS/°C 0.004
Operating: -10/+40
Temperature Range °C Storage: -40/+70
EMC performance MID Class E2 (Industrial Locations)
Note: Shield is connected to DB9
I/O Protection, All Pins Reversed Polarity; Excess Voltage and Surge
connector body.
Isolation Body/ Electronics at 500VDC GΩ ≥1
Cable 24AWG, 4 Conductor, Black, TPM Cable
Cable Length in 24 +1/-0
Vibration 2.5G Operational; 5G Non-Operational
Environmental Protection as per IEC 529 IP67
Corrosion Resistance Anodized aluminum

PART NUMBERS
Capacity(kg) Part No.
100 4053D-000-00
04.25.20 | 205712-7 | SP63

Dimensions and specifications subject to change without notice

Group Four Transducers


22 Deer Park Drive, Phone : (800) 419 1444
E. Longmeadow, MA 01028 Fax : (413) 525 -6182
www.groupfourtransducers.com [email protected]