G65 and G100
Diaphragm Meters
The diaphragm meters G65 and G100 are designed for industrial KEY BENEFITS
applications. The design is based on high measuring accuracy and » Long term accuracy and reliability
» Robust, maintenance free meter
a long lifetime and are maintenance free.
» MID approved
This performance is made possible through the principle of two
» Wide measuring range
measuring chambers, which are driven by the pressure of the gas. » Low pressure loss
The measured volume is displayed on a numeric totalizer.
Technical Specifications
Measuring Range G65 Qmin 0.65 m3/h
Qmax 100 m3/h
G100 Qmin 1.00 m3/h
Qmax 160 m3/h
European Metrological Approval N° DE-10-MI002-PTB004 Rev.1
Approval (04/22/EC)
Temperature Range Operation temperature: -25°C to +55°C.
Storing temperature: -40°C to +70°C.
Maximum Working 500 mbar
Pressure
High Temperature The meter can be delivered, as an option, with a HTL version PN0.1
Loading (HTL) Single Pipe welded type
Connections Double and single flange connections, DN80 for G65 and DN100 for G100
Totalizer Equipped with a magnetic coupling, as standard. As an option, a
stuffing box version is also available
8-digit index with IP 54 protection
UV resistant cover
Fitted with a reflecting disc in the first drum to facilitate periodical checks
Reverse flow device The meter is equippped with a device which prevents registration
of reverse flow
Housings Welded (G65 single pipe & G100) or Drawn (G65 double pipe) with
powder coating
Colour Light grey RAL 7035
Double Pipe drawn type
SPECIFICATIONS knowledge to shape your future
TECHNICAL DESIGN
Totaliser
A direct or indirect driven register, depending on the type of coupling between the
measuring unit and the index box, indicates the passed volume of gas.
Both index box-constructions are designed in such a way that it’s impossible to access
the registers without damaging them.
Measuring unit
Totaliser with Cyble target
The measuring unit consists of two chambers with synthetic and gas-tight diaphragms,
which is moved by the differential between the inlet and outlet pressure. A transmission
gear and a magnetic coupling / stuffing box transfer the reciprocating motion to the
mechanical index.
The unit is built in a robust steel coated casing, either drawn or welded.
Accuracy
In accordance with the MID and OIML standards.
In line with MID standards, the tolerance of acceptation is +/-3 % from Qmin to 0.1
Qmax and +/-1.5% from 0.1 Qmax to Qmax.
Typical error curve
Measuring unit Error in %
4
3
2
1
0
-1
-2
-3
-4
0 10 20 30 40 50 60 70 80 90 100
EN1359 and MID Error in % % Flow rate (m3/h)
Totaliser with LF “cable” Every meter undergoes a 100% inspection for function, accuracy and safety.
All meters are EN1359 compliant and have DVGW approval.
LF pulse-emitter
Meter versions with the sardine index box are standard equipped with a
LF pulse-emitter.
1 pulse is 0.1m3 (G65) or 1 m3 (G100).
The 4 pins male-connector is fixed in a “D”-hole in the index box. The female contra-
connector is supplied with each meter.
The RF1 index box is available with a permanent magnet in one of the index drums as
standard and can be refitted with a pulse transmitter (reed switch).
Totaliser with Double LF “Binder plug”
G65-G100 VERTICAL VERSION
d b
Dimensions and Technical Data
c a
Q min Qmax Vol. Pmax Flange a b c d h Weight
Type Nozzle Type
m3/h m3/h dm3 bar DN mm mm mm mm mm kg
G65 Drawn 0.65 100 55 0.5 80 500 700 217 445 687 48
G65 Drawn 0.65 100 55 0.5 80 640 840 216 445 790 52
h
G65 Welded - EP 0.65 100 55 0.5 80 N/A 700 216 436 737 71
G100 Welded 1 160 123 0.5 100 675 894 257 532 885 105
G100 Welded 1 160 123 0.5 100 710 894 257 532 885 105
G100 Welded - EP 1 160 123 0.5 100 N/A 894 257 532 920 113
G65b Double pipe Drawn (500)
EP = Single nozzle.
d b d b d b
c a c a
c
h
h
Single Pipe Welded G100 Double Pipe Welded (675) G100 Double Pipe Welded (710)
d a
G65 HORIZONTAL VERSION c b
This version, which has also the same G65 internal parts as the other G65 meters, is
standard equipped with magnet coupling and RF1-Index box.
Dimensions and Technical Data
h
Nozzle Q min Qmax Vol. Pmax Flange a b c d h1 h Weight
Type
Type m3/h m3/h dm3 bar DN mm mm mm mm mm mm kg
h1
G65 Welded 0.65 100 55 0.5 80 680 654 212 432 400 626 69
G65 horizontal version
OPTIONS
On request the following options are possible
» AMR/AMI solution: Totaliser pre-equipped with a Cyble target
» Thermowell (second one for reference measuments on special request)
» Other flange dimensions
» Pressure tapping point
» Retrofittable Low Frequency (LF) transmitter in different versions (Cable, Binder plug)
Information to be specified
when ordering:
» Nature of gas
» Measuring range (G65 or G100)
» Specific marking (serial number,
customer logo, bar code)
» Maximum working pressure
» Version (horizontal or vertical)
» Meter interaxis and connection type
» Accessories and options
ITRON GmbH
For more information, contact your local sales representative or agency:
Hardeckstraße 2
D-76185 Karlsruhe
Germany
Phone: +49-721 5981 0
Fax: +49-721 5981 189