0% found this document useful (0 votes)
32 views11 pages

E - 2164 VIF BUILDING at SEEB - R0 (11-06-2025)

The document outlines general notes and specifications for a construction project, including dimensions, materials, and compliance standards for structural steel and welding. It details design loads, painting specifications, and installation requirements for anchor bolts. Additionally, it includes information on wall and roof sheeting materials and notes for the main contractor regarding wall thickness confirmation.

Uploaded by

mustafazahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views11 pages

E - 2164 VIF BUILDING at SEEB - R0 (11-06-2025)

The document outlines general notes and specifications for a construction project, including dimensions, materials, and compliance standards for structural steel and welding. It details design loads, painting specifications, and installation requirements for anchor bolts. Additionally, it includes information on wall and roof sheeting materials and notes for the main contractor regarding wall thickness confirmation.

Uploaded by

mustafazahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

GENERAL NOTES :-

1]. ALL DIMENSIONS ARE IN MM (U.N.O.)

2]. NO DIMENSIONS TO BE SCALED OFF THE DRAWING.


ONLY WRITTEN DIMENSIONS TO BE FOLLOWED.
3]. HOT ROLLED SECTIONS SHALL BE
COMPLIED TO BS EN 10025 S355 JR GR.43 (fy=275N/mm2) &
BUILT UP SECTIONS SHALL BE
COMPLIED BS EN 10025 S355 JR GR.50 (fy=355N/mm2)

4]. ANCHOR BOLTS SHALL CONFORM TO BS EN ISO 898-1 (Gr. 4.6.)


KT)
BYM 5]. ALL CONNECTION BOLTS SHALL CONFORM TO BS EN ISO 4017 Gr. 8.8.
T
R (NO
TA INE 6]. WELDING ELECTRODE SHALL COMPLY TO AWS A5.20 E71T-1C
N
CO
7]. WELDED JOINTS FOR WEB IS AT 3000mm & FOR FLANGES IS
AT 6000mm (OR) AS PER DESIGN.

BP1 BP2 BP2 BP2 BP2 BP3 8]. WEB TO FLANGE WELDS ARE SINGLE SIDE FILLET WELD IN
ACCORDANCE WITH THE NINTH EDITION OF THE AISC TABLE,
J2.4 PAGE 5-67 UNLESS NOTED OTHERWISE.
9]. READ THIS DRG. WITH RESPECT TO RELEVANT STRUCTURAL,
M&E DRGS. DISCREPANCY & FABRICATION/ERECTION
DIFFICULTIES IF ANY SHALL BE BROUGHT TO MK TRADING NOTICE
BEFORE THE COMMENCEMENT OF FABRICATION.

10]. THE INSTALLATION OF ANCHOR BOLTS AND EMBEDDED ITEMS


MUST BE DONE IN ACCORDANCE WITH THE CODE OF STANDARD
PRACTICE FOR STEEL BUILDINGS OF AISC SECTION 7.
ANCHOR BOLTS AND FOUNDATION BOLTS SHALL BE SET BY THE
OWNER (OR HIS CIVIL CONTRACTOR) IN ACCORDANCE
BP4 BP4a WITH M.K.TRADING "ISSUED FOR CONSTRUCTION"

ANCHOR BOLT PLAN MAXIMUM ALLOWANCE TOLERANCES


ARE AS FOLLOWS.

a) 3mm CENTER TO CENTER OF ANY TWO BOLTS WITHIN


AN ANCHOR BOLT GROUPS.
b) 6mm CENTER TO CENTER OF ADJACENT ANCHOR BOLT GROUPS.
c) ELEVATION OF THE TOP OF ANCHOR BOLTS +/- 12mm.

DESIGN LOADS:-

(i) LIVE LOAD = 0.600 kN/Sqm

(i) DEAD LOAD = 0.150 kN/Sqm


BP1a BP2a BP2a BP2a BP2a BP3a
(iii) WIND = 57 m/s ,3 SEC GUST, EXPOSURE: ' C '

(iv) COLLATERAL LOAD = 0.200kN/Sqm

WIND CODE : ASCE-7-2010

DESIGN CODE : AISC10

PAINTING SPECIFICATION:
ALL STRUCTURAL STEEL MAIN MEMBERS WILL BE SWEEP BLAST
AND COATED WITH ONE COAT OF PENGUARD EXPRESS
-75 MICRONS DFT (GREY)

ALL PURLINS,FLANGE BRACING WILL BE PRE-GALVANIZED STEEL


WHICH IS ROLL FORMED OR PRESS BENT AND SIZES SHALL BE
AS PER OUR DESIGN WITHOUT ANY FIRE PAINT / TOP COAT

1 6

A C 2 5

A C

Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

1 6 ANCHOR BOLT SETTING DETAIL

SCHEDULE OF ANCHOR BOLT


BASE PLATE DETAIL - BP1 & BP1a BASE PLATE DETAIL - BP2 & BP2a
BASE PLATE DETAIL - BP4 & BP4a
BASE PLATE DETAIL - BP3 & BP3a DIAMETER OF A B C
ANCHOR BOLT mm mm mm

20Ø 600 75 110


NOTE:-
1- FOUNDATION TO BE DESIGNED FOR THE MOST CRITICAL LOAD COMBINATION
2- IMP. NOTE :- ADD 10% EXTRA TO ALL LOADS TO COVER ACCIDENTAL FACTOR
3- BARCED BAY/WIND BENT REACTION MUST BE ADDED WITH MAIN FRAME COLUMNS
REACTION AT BRACED BAY LOCATION
4- FOUNDATION DESIGN IS NOT THE RESPONSIBILITY OF MKT.

V +VE

H+VE

REACTION POINT

SIGN CONVERSATION

RIGID FRAME: BASIC COLUMN REACTIONS (kN)

ENDWALL COLUMN: BASIC COLUMN REACTIONS (kN)

BUILDING BRACING REACTIONS


Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450
Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450
Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450
SECTION-(A-A)

Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450
TYP. PURLIN/GIRT LAPPING DETAIL TYP. CABLE BRACING FIXING DETAIL

RIDGE DETAIL
INTERMEDIATE DETAIL

SAGROD FIXING DETAIL


Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

TYP. DETAIL OF CONTAINER OPENING


Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

TYP. ROLLING SHUTTER


OPENING

TYP. DETAIL OF ROLLING SHUTTER OPENING


GABLE END FASCIA DETAIL WITH LINER
SECTION-(C-C)
Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

TYP. ROLLING SHUTTER


OPENING

TYP. DETAIL OF ROLLING SHUTTER OPENING


SLOPE 1: 10

SLOPE 1: 10

SLOPE 1: 10
SLOPE 1: 10

SLOPE 1: 10

SLOPE 1: 10
ROOF SHEETING :-
REFER SHEET NO.07 FOR SECTION C-C
TOP SHEET : 0.40mm THK. GI. SINGLE SKIN POLYESTER COLOR COATED PROFILE SHEET.
INSULATION : 50MM THK. PU INSULATION HAVING 35kg/m3 DENSITY.
LINER SHEET : 0.35mm THK. GI SINGLE SKIN POLYESTER COLOR COATED LOW RIBBED SHEET.

Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

GABLE END FASCIA DETAIL WITH LINER


SECTION-(B-B)
WALL SHEETING :-
TOP SHEET : 0.40mm THK. GI. SINGLE SKIN POLYESTER COLOR COATED PROFILE SHEET.
INSULATION : 50MM THK. PU INSULATION HAVING 35kg/m3 DENSITY.
LINER SHEET : 0.35mm THK. GI SINGLE SKIN POLYESTER COLOR COATED LOW RIBBED SHEET.

Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

NOTE :~ BLOCK WALL & PLASTER THICKNESS TO


BE CONFIRMED BY MAIN CONTRACTOR
BEFORE FABRICATION
WALL SHEETING :-
TOP SHEET : 0.40mm THK. GI. SINGLE SKIN POLYESTER COLOR COATED PROFILE SHEET.
INSULATION : 50MM THK. PU INSULATION HAVING 35kg/m3 DENSITY.
LINER SHEET : 0.35mm THK. GI SINGLE SKIN POLYESTER COLOR COATED LOW RIBBED SHEET.

ROLLING SHUTTER ROLLING SHUTTER


(NOT BY MKT) (NOT BY MKT)

EAVE DETAIL WITH GUTTER

A C P CLADDING (NOT BY MKT)

TYP.RIDGE DETAIL

Bushar-Al Ansab,Muscat
HEC
Engineering Consultancy
P.O.BOX NO.782 .P.CODE-130
Tel : 71149450

ROLLING SHUTTER ROLLING SHUTTER


(NOT BY MKT) (NOT BY MKT)

You might also like