0% found this document useful (0 votes)
30 views8 pages

Ams2710 Datasheet

The AMS 2710 is a miniaturized PCB pressure sensor module that provides a 0 to 10 V output across various pressure ranges, featuring fully calibrated and temperature compensated measurements. It is designed for industrial applications with a supply voltage range of 12 to 36 V, and offers high precision and long-term stability. The sensor is available in multiple configurations for different pressure types, including differential, absolute, and barometric pressures, and is compliant with RoHS and REACH standards.

Uploaded by

maymoun jabnouni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views8 pages

Ams2710 Datasheet

The AMS 2710 is a miniaturized PCB pressure sensor module that provides a 0 to 10 V output across various pressure ranges, featuring fully calibrated and temperature compensated measurements. It is designed for industrial applications with a supply voltage range of 12 to 36 V, and offers high precision and long-term stability. The sensor is available in multiple configurations for different pressure types, including differential, absolute, and barometric pressures, and is compliant with RoHS and REACH standards.

Uploaded by

maymoun jabnouni
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

AMS 2710

PCB pressure sensor module with 0 .. 10 V output

FEATURES GENERAL DESCRIPTION


 Universal pressure sensor module with AMS 2710 is a series of miniaturized pressure
0 .. 10 V voltage output sensor modules with analog 0 .. 10 V output in
various pressure ranges. The sensor modules are
 Fully calibrated and temperature calibrated and temperature compensated in a wide
compensated sensor module temperature range of -25 .. 85 °C and allow
 Variants for (bidirectional) differential, gage, precise pressure measurements with high long
absolute and barometric pressure term stability.

 Wide variety of pressure ranges: With its large supply voltage range of 12 .. 36 V,
5 mbar up to 2 bar reverse polarity protection (Vs - GND) and the
current limited voltage output the sensor modules
 Piezoresistive sensing principle AMS 2710 are especially suitable for applications
in industrial environments.
 High precision signal conditioning
AMS 2710 can be easily integrated in other
 Typical accuracy < 0.5 %FSO @ room
assemblies or used stand alone in a suitable
temperature for standard pressure ranges
package. Pressure is applied via metal pressure
 Typical overall error < 0.7 %FSO within ports, the electrical connection can be done via
-25 .. +85 °C for standard pressure ranges solder pads, pin connectors or a PCB terminal
block.
 Supply voltage range: 12 .. 36 V
The pressure sensor modules in the AMS 2710
 Integrated circuit protection against reverse series are available for various pressure ranges
polarity, current limited output and types: Differential (relative) devices in
 Different product variants with solder pads, pressure ranges from 0 .. 5 mbar up to 0 .. 2 bar,
terminal block or DIL pins absolute pressure variants for 0 .. 1 and 0 .. 2 bar
as well as a barometric type for 0.7 .. 1.2 bar.
 Ready for packaging or integration in other Bidirectional differential devices are available from
assemblies -5 .. +5 mbar up to -1 .. +1 bar for measurement of
positive and negative pressure differences. Other
 Compact size (30 mm x 27.5 mm x 14.3 mm)
pressure ranges or modifications are available on
 RoHS and REACH compliant request.

TYPICAL APPLICATIONS
 Static pressure sensing
 Dynamic pressure sensing
 Barometric pressure sensing
 Vacuum measurement
 Level measurement
 Gas flow measurement
 Heating, Ventilation and Air Conditioning
(HVAC)

Phone:+49 (0)6131/91 0730-0


Fax: +49 (0)6131/91 073-30
Internet: www.analogmicro.de
E–Mail: [email protected]
Analog Microelectronics GmbH
An der Fahrt 13, D – 55124 Mainz February 2018 - Rev. 1.0, preliminary
AMS 2710
PCB pressure sensor module with 0 .. 10 V output

PRESSURE RANGES
Pressure sensor Pressure type Pressure Burst Pressure Burst
1) 1)
module type (code) range pressure range pressure
in mbar in bar in PSI in PSI
Ultra low pressure
AMS 2710-0005-D differential / relative 0 .. +5 > 0.2 0 .. 0.073 >3
AMS 2710-0010-D differential / relative 0 .. 10 > 0.2 0 .. 0.145 >3
AMS 2710-0005-D-B bidirectional differential -5 .. +5 > 0.2 -0.073 .. +0.073 >3
AMS 2710-0010-D-B bidirectional differential -10 .. +10 > 0.2 -0.145 .. +0.145 >3
Low pressure
AMS 2710-0020-D differential / relative 0 .. 20 > 0.4 0 .. 0.290 >6
AMS 2710-0050-D differential / relative 0 .. 50 >1 0 .. 0.725 > 15
AMS 2710-0100-D differential / relative 0 .. 100 >1 0 .. 1.450 > 15
AMS 2710-0020-D-B bidirectional differential -20 .. +20 > 0.4 -0.290 .. +0.290 >6
AMS 2710-0050-D-B bidirectional differential -50 .. +50 >1 -0.725 .. +0.725 > 15
AMS 2710-0100-D-B bidirectional differential -100 .. +100 >1 -1.450 .. +1.450 > 15
Standard pressure
AMS 2710-0200-D differential / relative 0 .. 200 >5 0 .. 2.901 > 72
AMS 2710-0350-D differential / relative 0 .. 350 >5 0 .. 5.076 > 72
AMS 2710-0500-D differential / relative 0 .. 500 >5 0 .. 7.251 > 72
AMS 2710-1000-D differential / relative 0 .. 1000 >5 0 .. 14.50 > 72
AMS 2710-2000-D differential / relative 0 .. 2000 >5 0 .. 29.01 > 72
AMS 2710-0200-D-B bidirectional differential -200 .. +200 >5 -2.901 .. +2.901 > 72
AMS 2710-0350-D-B bidirectional differential -350 .. +350 >5 -5.076 .. +5.076 > 72
AMS 2710-1000-D-B bidirectional differential -1000 .. +1000 >5 -14.50 .. +14.50 > 72
AMS 2710-1000-A absolute 0 .. 1000 >5 0 .. 14.50 > 72
AMS 2710-2000-A absolute 0 .. 2000 >5 0 .. 29.010 > 72
AMS 2710-1200-B barometric 700 .. 1200 >5 10.15 .. 17.40 > 72

Table 1: AMS 2710 standard pressure ranges (other ranges on request)

Notes:
1) Burst pressure is defined as the maximum pressure, which can be applied to one pressure port relative to the
other port (or while only one pressure port is connected) without causing damages / leaks.

MAXIMUM RATINGS
Parameter Minimum Typical Maximum Units
Absolute maximum supply voltage: Vmax 36 V
Operating and storage temperature: T -25 85 °C
1)
Common mode pressure: pCM 16 bar
Output short circuit resistance duration against GND 1800 s

Table 2: Maximum ratings


Notes:
1) Common mode pressure is defined as the maximum pressure, which can be applied simultaneously on both pressure
ports of a differential or bidirectional pressure sensor module without causing damages, while no differential pressure
is applied.

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 2/8


AMS 2710
PCB pressure sensor module with 0 .. 10 V output

SPECIFICATIONS
All parameters apply to VS = 24 V, Top = 25°C and RL = 10 kΩ, unless otherwise stated.
Parameter Minimum Typical Maximum Units
Analog output signal
1)
@ specified minimum pressure (see “pressure ranges”) 0 < 0.025 0.05 V
1)
@ specified maximum pressure (see “pressure ranges”) 10 V
2)
Full span output (FSO) 10 V
without pressure (only bidirectional differential types) 5 V
3)
Accuracy @ Top = 25°C
Ultra low pressure types (5, 10 mbar) ±1.0 ±1.5 %FSO
Low pressure types (20, 50, 100 mbar) ±0.5 ±1.0 %FSO
Standard pressure types (≥ 200 mbar) ±0.5 ±1.0 %FSO
4)
Overall error @ Top = -25 .. 85°C
Ultra low pressure types (5, 10 mbar) ±1.5 ±2.5 %FSO
Low pressure types (20, 50, 100 mbar) ±1.0 ±2.0 %FSO
Standard pressure types (≥ 200 mbar) ±0.7 ±1.5 %FSO
Long term stability < 0.5 %FSO/a
5)
Nonlinearity -0.3 < 0.1 0.3 %FSO
Resolution analog output signal 0.05 %FSO
Supply voltage (VS to Ground) 12 24 36 V
Current consumption 10 mA
Response time (10% .. 90% rise time) 1 2 ms
Load resistor RL 1 kΩ
Capacitive load 50 nF
6)
Dependency of VOUT on VS < 0.1 %FSO
6
Pressure Changes 10
Compensated operating temperature range -25 85 °C
Weight (AMS2710 without terminal block) 6.7 gram
3
Dimensions (l x w x h, standard version with tubes) 30.0 x 27.5 x 14.3 mm
7), 8)
Media compatibility See notes

Table 3: Specifications

SPECIFICATION NOTES:
1) Pressure ranges are specified in Table 1.
2) The Full Span Output (FSO) is the algebraic difference between the output signal at the specified minimum
pressure and the output signal at the specified maximum pressure (nominal FSO = 10 V).
3) The accuracy is defined as the maximum deviation of the measurement value from the ideal transfer function at
room temperature (RT) in %FSO including the adjustment error (offset and span), nonlinearity, pressure
hysteresis and repeatability. Nonlinearity is the measured deviation from the best fit straight line (BFSL) across
the entire pressure range. Pressure hysteresis is the maximum deviation of the output value at any pressure
within the specified range when the pressure is cycled to and from the specified minimum or maximum pressure.
Repeatability is the maximum variation of the output value at any pressure within the specified range over 10
pressure cycles.
4) The overall error (also known as total error band, TEB) is defined as the maximum deviation of the measurement
value from the ideal transfer function in %FSO across the entire temperature range (-25 .. 85 °C).

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 3/8


AMS 2710
PCB pressure sensor module with 0 .. 10 V output

5) Defined as best fit straight line (BFSL).


6) The given value is the maximum deviation from the output voltage at VS = 24 V over the complete supply voltage
range at any pressure in the specified range. It is normalized to the FSO.
7) Media compatibility of pressure port 1 (for a description of port 1, see Figure 3): fluids and gases non-corrosive to
ceramics, silicon, Pyrex and RTV silicone rubber.
8) Media compatibility of pressure port 2 (for a description of port 2, see Figure 3): clean, dry gases, non-corrosive to
ceramics, silicon, RTV silicone rubber, gold and tin (alkaline or acidic liquids can destroy AMS 2710).

FUNCTIONAL DESCRIPTION
AMS 2710 pressure sensor modules combine piezoresistive pressure sensing technology with modern
mixed-signal conditioning on a compact PCB.
The physical pressure to be measured is converted into a differential voltage signal at AMS 2710’s
piezoresistive pressure sensing element. This differential voltage is signal-conditioned and converted into a
standardized 0 .. 10 V voltage output signal in the following way (see Figure 1):
At first the sensing element’s differential voltage signal is pre-amplified and converted into a digital signal
using a 14-bit ADC. This digitized signal is processed mathematically by the ASIC’s integrated
microcontroller unit (μC) to achieve a calibrated and temperature compensated output signal. Herefore the
μC uses a correction algorithm and individual correction coefficients stored in the ASIC’s EEPROM during
AMS 2710’s factory calibration process. The temperature value needed for temperature compensation is
measured directly at the pressure sensing element. An 11-bit DAC reconverts the corrected digital signal into
an analog voltage signal, which is then amplified to obtain the 0 .. 10 V output voltage VOUT.
AMS 2710’s output voltage VOUT is independent of the applied supply voltage and a linear function of the
1
applied pressure p . It is given by:
p  pmin
VOUT ( p )   10 V (1)
pmax  pmin

wherein pmin is the sensor’s specified minimum pressure and pmax is the specified maximum pressure, given
by the sensor’s pressure range in Table 1.

Figure 1: AMS 2710’s block diagram

1
The applied pressure p is the pressure difference between port 1 and 2 for differential and bidirectional differential
pressure sensor modules. For relative pressure types it is the pressure difference between port 1 and ambient pressure
and for absolute and barometric pressure types it is the pressure at port 2 (for the definition of ports see Figure 3).

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 4/8


AMS 2710
PCB pressure sensor module with 0 .. 10 V output

INITIAL OPERATION
AMS 2710 can be screw mounted using the four through bores (Ø 3 mm for M2.5 screws) at its edges. As an
alternative the DIL version can be plugged or soldered on a PCB using its ten DIL pins.
AMS 2710’s electrical connection is shown in Figure 2. Vs and GND are directly connected to the power
supply’s positive output and GND. Vout can be connected to a voltmeter directly to measure the output
signal voltage VOUT (referenced to GND) or a load resistor RL can be connected between Vout and GND and
VOUT can be measured parallel to RL. Please take care that the power supply is set to a voltage in the range
between 12 and 36 V and that it is able to source at least 10 mA (for RL ≥ 10 kΩ).
In practice the electrical connection can be established in the following ways: In the standard version (type
AMS 2710-XXXX-Y-1, where XXXX has to be replaced with the four-digit pressure range and Y with the
symbol for the pressure type, see “Information for Ordering”) it is possible to solder wires to the respective
soldering pads (see Figure 3) or to use a male multipoint connector (matching to TE connector 215297-5). In
the terminal block version (type AMS 2710-XXXX-Y-2) a terminal block allows the installation of a three-wire
cable without soldering. The DIL version (type AMS2710-XXXX-Y-3) can be easily plugged or soldered onto
a PCB using the sensor’s DIL pins.
The pressure connection is made using AMS 2710’s metal pressure ports. Depending on the used type of
pressure sensor module and the type of measuring pressure one or two of the pressure ports have to be
connected to the measuring media/volume. For the pressures at port 1 and port 2 (for definition of the ports
see Figure 3) the following requirements have to be fulfilled, where p1 is the pressure at port 1 and p2 is the
pressure at port 2:
for differential pressure (type AMS 2710-XXXX-D-..): p1 > p2
for relative / gage pressure (type AMS 2710-XXXX-D-..): p1 > pambient, p1 = measuring pressure
for bidirectional differential pressure (type AMS 2710-XXXX-D-B-..): p1 > p2 or p1 < p2 possible
for absolute pressure (type AMS 2710-XXXX-A-..): p2 = measuring pressure
for barometric pressure (type AMS 2710-XXXX-B-..): p2 = measuring pressure
The maximum pressures (see Table 1) and the guidelines concerning media compatibility (specification
notes 7) and 8)) have to be taken into account.

Figure 2: Electrical connection of AMS 2710

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 5/8


AMS 2710
PCB pressure sensor module with 0 .. 10 V output

DIMENSIONS AND PINOUT

Figure 3: Dimensions and pinout of AMS 2710

Notes:
1. Absolute and barometric pressure types only have pressure port 2.
2. The electrical connection can be established using the soldering pads, a male multipoint connector
(matching to TE connector 215297-5), a terminal block or DIL pins.
3. For pressure connections Analog Microelectronics recommends a silicone tubing (inner diameter ØID = 2 mm,
outer diameter ØOD = 6 mm).
4. If silicone tubing is used it is recommended to use hose clamps.

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 6/8


AMS 2710
PCB pressure sensor module with 0 .. 10 V output

INFORMATION FOR ORDERING

Ordering code:

Pressure range:
Pressure range code mbar PSI kPa
0005 5 0.073 0.5
0010 10 0.145 1
0020 20 0.290 2
0050 50 0.725 5
0100 100 1.450 10
0200 200 2.901 20
0350 350 5.076 35
0500 500 7.251 50
1000 1000 14.50 100
1200 1200 17.40 120
2000 2000 29.01 200

Table 4: Pressure ranges

Pressure type:
Pressure type code Available pressure ranges
D differential / relative (gage) 0 .. 5 mbar to 0 .. 2 bar
D-B bidirectional differential -5 .. +5 mbar to -1000 .. +1000 mbar
A absolute 0 .. 1000 mbar and 0 .. 2000 mbar
B barometric (absolute) 700 .. 1200 mbar

Table 5: Pressure types

Electrical connection type:


Code Connection type
1 standard version Soldering pads and female connector
2 terminal block version Terminal block with screws
3 DIL version Pins

Table 6: Electrical connections

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 7/8


AMS 2710
PCB pressure sensor module with 0 .. 10 V output

ADDITIONAL EQUIPMENT
ORDER NUMBER DELIVERY FORM
AMS2710-TUBING matching silicone tubing (please order in meters)

NOTES

Analog Microelectronics GmbH reserves the right to amend any dimensions, technical data or other information contained herein without prior notification.

www.analogmicro.de

February 2018 - Rev. 1.0, preliminary Page 8/8