SOVISY INDIA PVT. LTD.
INTERNAL INSPECTION REPORT FOR SMC/GRP PANELS
Date : 09.07.2025
Tank Size, Capacity & Qty. : 9 X 2.5 X 1 mtr., 22.5 kL, 03 nos.
11-15, D.K. Industrial Estate-2,
6 X 4 X 1 mtr., 24 kL, 01 nos.
Chhatral - 382729
Tal.-Kalol. Distt.-Gandhinagar (Guj.) 4 X 4 X 1 mtr., 16 kL, 01 nos.
4 X 2 X 1 mtr., 08 kL, 01 nos.
4 X 1 X 1 mtr., 04 kL, 01 nos.
Client Name : M/s Jaipur Motels & Buildestates Pvt. Ltd., Jaipur, Work Order Details : 118/2025-26 Dated : 20.06.2025
Rajasthan.
Product Description : Product Category : Compression Moulding : Sheet Moulding Compound
Hot Press Moulded Thermosetting Glass Fibre Reinforced Polyster (GRP) Resin Sectional
SMC/GRP PANELS Basic Raw Material :
Water Storage tanks
Parameter / Relevent Product
Characteristics Standard : Sample / Frequency of
Sr. No Requirement Specified Test Method / Instruments Observed Value
IS 14399 PART I&II Testing
to be tested 1996
PRODUCT TESTING
1. ROUTINE TESTS
A. VISUAL
I Inspection Of Panel Clause 7 To be free from following defects. Visually under Adequate Free from all 5 nos / Once for each lot
i. Crack / Damage light Defects as per for each type of Panels
ii Short Moulding Specified Requirement
iii. Blister / Air Bubbles
iv. Pinholes
v. Warpage / Deshape
vi. Material Mixing
5 nos /
Visually under adequate
II Colour Clause 5 Ivory Ivory Once for each lot for each
light colour for comparison
type of Panels
B. DIMENSIONAL
I Thickness of panel Clause 6.4 Type ‘A’ - 3 mm Min. Digital Micrometer i. Type 'A' - 4 mm to
10 mm Once for each lot for each
Ceiling Panel - 3.5 to type of Panel
7.5 mm
i. 1000x1000 mm, 1000x500 mm i. 1000 x 1000 mm
II External size of panel Clause 6.1 to 6.3
External dimensions tolerance within ± 0.2 % 1000 x 500 mm 5 nos /
Measuring tape, Angle
Once for each lot for each
Protractor, Digital Calliper ii. Satisfactory
ii. Tolerance on angles within ± 0.3° type of Panels
PAGE : 1 of 3
Parameter / Relevent
Sr. No Characteristic Product/Material Requirement Specified Results Obtained Test Method Sample size Remarks
to be tested Standard
2. ACCEPTANCE TEST
A Mechanical and Physical Properties
Sample 1 - 91.23 Mpa Annex B of
Sample 2 - 78.27 Mpa IS 14399 (P-1): 1996
IS 14399 (P-1): 1996
I Tensile Strength 70 MPa (Min) Sample 3 - 77.31 Mpa 5 Satisfactory
–Clause 8
Sample 4 - 79.71 Mpa
Sample 5 - 84.65 Mpa
Sample 1 - 152.4 Mpa Annex C of
Sample 2 - 155.3 Mpa IS 14399 (P-1): 1996
IS 14399 (P-1): 1996
II Bending Strength 100 MPa (Min) Sample 3 - 148.1 Mpa 5 Satisfactory
–Clause 8
Sample 4 - 139.6 Mpa
Sample 5 - 143.7 Mpa
Elastic Modulus IS 14399 (P-1): 1996 Sample 1 - 10529 MPa Annex D of
III 6000 MPa (Min) 2 Satisfactory
in bend –Clause 8 Sample 2 -12691 MPa IS 14399 (P-1): 1996
Sample 1 - 31.9 % Annex E of
IS 14399 (P-1): 1996
IV Glass Content 25 % ( Min) Sample 2 - 32.47 % 3 Satisfactory
–Clause 8 IS 14399 (P-1): 1996
Sample 3 - 32.16 %
Sample 1 : 54 - 59 BHU Annex F of
Sample 2 : 53 - 61 BHU
IS 14399 (P-1): 1996
V Barcol Hardness 50 BHU (Min) Sample 3 : 55 - 60 BHU 5 Satisfactory
–Clause 8 IS 14399 (P-1): 1996
Sample 4 : 54 - 60 BHU
Sample 5 : 53 - 60 BHU
IS 14399 (P-1): 1996 Sample 1 - 0.09 % Annex G of
VI Water Absorption 0.5 % (Max) 2 Satisfactory
–Clause 8 Sample 2 - 0.14 % IS 14399 (P-1): 1996
B Hydrostatic and Deflection tests
Each type of the panels should withstand the Panels withstood
following pressure without bursting, cracking or following pressure
Hydrostatic Testing of IS 14399 (P-1): 1996 leakage without bursting, Annex H of IS 14399 (P- 1 No. of each
I Satisfactory
Panels –Clause 9 cracking or leakage 1) : 1996 type panel
Panel Pressure Value
i. Type ‘A’ – 0.04 MPa i. Type 'A' -- 0.04 Mpa
PAGE : 2 of 3
Parameter / Relevent
Sr. No Characteristic Product/Material Requirement Specified Results Obtained Test Method Sample size Remarks
to be tested Standard
W01 Panel - 3.91 mm
(Type 'A' Side Panel) Dial gauge graduated to
Not to exceed 10 mm immediately after
D1 Panel - 3.27 mm 0.01 mm. (Done 1 No. of each
II Deflection Test Clause 10 reaching working pressure and once again after Satisfactory
(Type 'A' Drain Panel) simultaneously with type panel
maintaining pressure for 4 hrs.
B1 Panel - 2.14 mm Hydrostatic Testing)
(Type 'A' Bottom Panel)
C TYPE TESTS
To be tested for effect of panel on water for
taste / odour /colour turbidity/ toxic metals/
Satisfactory Results obtained As per Tested at Shri Ram Institute For
I Potability of water Clause 11.2 to 11.5 cytotoxicity /microbiological growth. IS 14399 (P-1): 1996
as per Specifications specification Industrial Research, Delhi
Once in 3 years or whenever material grade or
compounding formulation changes.
PAGE : 3 of 3
Prepared by : Checked & approved by :