0% found this document useful (0 votes)
29 views20 pages

Aqua Rite Product Manual

The document outlines the maintenance requirements for an electrolytic chlorine generator used in pool sanitation, detailing ideal ranges for free chlorine, pH, alkalinity, salt, stabilizer, and calcium, along with necessary adjustments. It includes safety instructions, warranty information, troubleshooting tips, and operational guidelines for the Aqua Rite system. Regular inspections and chemical adjustments are emphasized to ensure optimal performance and safety of the pool system.

Uploaded by

Wayne Wamback
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views20 pages

Aqua Rite Product Manual

The document outlines the maintenance requirements for an electrolytic chlorine generator used in pool sanitation, detailing ideal ranges for free chlorine, pH, alkalinity, salt, stabilizer, and calcium, along with necessary adjustments. It includes safety instructions, warranty information, troubleshooting tips, and operational guidelines for the Aqua Rite system. Regular inspections and chemical adjustments are emphasized to ensure optimal performance and safety of the pool system.

Uploaded by

Wayne Wamback
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

ELECTROLYTIC CHLORINE GENERATOR

BASIC POOL MAINTENANCE REQUIREMENTS


TEST IDEAL RANGE ADJUSTMENT REQUIRED

Raise desired output % to


Free Chlorine 1.0 - 3.0 ppm increase, lower desired output %
WEEKLY

Aqua Rite
to decrease -OR- increase or
decrease pump filtration time. ®
pH 7.2 - 7.8
Too high - add muriatic acid
Too low - add soda ash.

Alkalinity 80 - 120 ppm Add baking soda to increase.


MONTHLY

Add acid as required to decrease.

Salt 2700 - 3400 ppm Add salt as required to increase.

Stabilizer 60 - 80 ppm Add cyanuric acid to increase.


QUARTERLY

Calcium 200 - 400 ppm Add calcium to increase.


Drain and add water to decrease.

Electrolytic Cell inspect & clean Refer to section in manual.

Head Loss Curve


14
13 Electronic Chlorine Generator
12 12.03
Head Loss (FtH O)

11
2

10
9
8
7
6.79
Operation and Installation
6
5 Manual
4
AQR
3 3.08
2
1
.82
0
40 (25%) 80 (50%) 120 (75%) 160 (100%)

Flow Rate (gpm)

620 Division St. 092009N RevP


Elizabeth, NJ 07207 Copyright © 2010 Hayward Inc. www.haywardnet.com
LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and
IMPORTANT SAFETY INSTRUCTIONS E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and
SwimPure chlorination products to be free of defects in materials and workmanship, under
When using this electrical equipment, basic safety precautions normal use and service, for a period of three (3) years. Hayward/Goldline also warrants its
Aqua Trol chlorination products to be free of defects in materials and workmanship, under
should always be followed, including the following: normal use and service for a period of one (1) year. These warranties are applicable from the
initial date of installation on private residential swimming pools in the US and Canada.

• READ AND FOLLOW ALL Hayward/Goldline warrants all the above-identified pool automation and chlorination prod-
ucts installed on commercial swimming pools and on swimming pools outside of the US and
INSTRUCTIONS Canada for a period of one (1) year. Likewise, Hayward/Goldline warrants all accessories
and replacement parts for the above-identified pool automation and chlorination products for
a period of one (1) year. Each of these warranties is not transferable and applies only to the
original owner.
• Use Copper Conductors Only
Proof of purchase is required for warranty service. If written proof of purchase is not
provided, the manufacturing date code will be the sole determinant of the date of installation
• Disconnect all AC power during installation. of the product. To obtain warranty service or repair, please contact the place of purchase or
the nearest Hayward/Goldline authorized warranty service center. For more information on
authorized service centers please contact the Hayward/Goldline Technical Service Support
• Warning - To reduce the risk of injury, do not permit Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the Goldline web site at
children to use this product unless they are closely www.goldlinecontrols.com or the Hayward website at www.haywardnet.com.
supervised at all times. WARRANTY EXCLUSIONS:
1. Material supplied or workmanship performed by others in process of installation.
• A green colored terminal marked "Earth Ground" is lo- 2. Damage resulting from improper installation including installation on pools larger than the
cated inside the wiring compartment. To reduce the risk product rating.
of electric shock, this terminal must be connected to the 3. Problems resulting from failure to install, operate or maintain the product(s) in accordance
with the recommendations contained in the owners manual(s).
grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to 4. Problems resulting from failure to maintain pool water chemistry in accordance with the
recommendations in the owners manual(s).
the circuit conductors supplying the equipment.
5. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or
alternations, fire, flood, lightning, freezing, external water, degradation of natural stone used in
• One bonding lug for US models (two for Canadian mod- or immediately adjacent to a pool or spa, war or acts of God.
els) is provided on the external surface. To reduce the
DISCLAIMER. THE EXPRESS LIMITED WARRANTIES ABOVE CONSTITUTE THE
risk of electric shock, connect the local common bonding ENTIRE WARRANTIES WITH RESPECT TO THE ABOVE-IDENTIFIED HAYWARD/
grid in the area of the swimming pool, spa, or hot tub to GOLDLINE POOL AUTOMATION AND CHLORINATION PRODUCTS AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WAR-
these terminals with an insulated or bare copper conduc- RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
tor not smaller than 8 AWG US / 6 AWG Canada. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO
HAVE OTHER RIGHTS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS
OF RENTING REPLACEMENTS, AND OTHER ADDITIONAL EXPENSES, EVEN IF
• All field installed metal components such as rails, ladders, THE SELLER HAD BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME STATES DO NOT ALLOW THE EXCLUSION OF LIMITATION OF INCI-
drains, or other similar hardware within 3 meters of the DENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR
pool, spa or hot tub shall be bonded to the equipment EXCLUSION MAY NOT APPLY TO YOU.
grounding bus with copper conductors not smaller than 8 NO WHOLESALER, AGENT, DEALER, CONTRACTOR OR OTHER PERSON IS
AWG US / 6 AWG Canada. AUTHORIZED TO PROVIDE, SUPPLEMENT OR MODIFY ANY WARRANTY ON
BEHALF OF HAYWARD/GOLDLINE.
THESE WARRANTIES ARE VOID IF THE PRODUCT HAS BEEN ALTERED IN ANY
• NOTICE TO USERS: This control product is to be used WAY AFTER LEAVING THE FACTORY. FOR THE ABOVE-IDENTIFIED CHLORI-
only in accordance with the directions of this label. It is NATION PRODUCTS, THESE WARRANTIES ALSO ARE VOID IF, DURING THE
WARRANTY PERIOD, YOU USE A REPLACEMENT CHLORINATOR CELL OTHER
an offense under the Pest Control Products Act to use a THAN AN UNMODIFIED, NEW HAYWARD/GOLDLINE CHLORINATOR CELL PUR-
control product under unsafe conditions. CHASED FROM HAYWARD/GOLDLINE. IF A WARRANTY BECOMES VOID, YOU
STILL MAY PURCHASE SERVICE AND/OR TELEPHONE TECHNICAL SUPPORT
AT THE THEN CURRENT TIME AND MATERIAL RATES.
• SAVE THESE INSTRUCTIONS 16
4. "Check Salt" LED illuminated or flashing
Be sure that the correct model Turbo Cell has been selected (page 7).
Check salt level in pool/spa. If salt level is low, add salt according to chart on page 4.
Before adding large quantities of salt, it is advisable to have your salt level profession-
ally checked.

5. "High Salt" LED illuminated


Be sure that the correct model Turbo Cell has been selected (page 7). Table of Contents
Check salt level in pool/spa. If salt level is too high, lower salt level by draining some of
the pool water out of the pool and replace with fresh water. Continue until the salt
concentration is at recommended levels.

6. "Inspect Cell" LED flashing OPERATION


Be sure that the correct model Turbo Cell has been selected (page 7). General.........................................................................................1
Inspect and clean cell according to directions on page 8. When done, press the "diag-
nostic" button for 3 seconds to stop the "Inspect Cell" LED flashing. Water Chemistry........................................................................2
7. "Inspect Cell" LED illuminated
Be sure that the correct model Turbo Cell has been selected (page 7). Controls........................................................................................6
Remove and inspect the cell for scale. If the cell is scaled, follow the directions on page
8 for cell cleaning. If the pool has the proper amount of salt and the "Inspect Cell" LED Maintenance.................................................................................8
is still illuminated, the cell may be worn and need replacement.
8. Possible causes of little or no free chlorine residual
- Aqua Rite® switch in OFF position. INSTALLATION
- Desired Output % adjustment setting is too low. Mounting........................................................................................10
- Low stabilizer (Cyanuric Acid).
- Filter pump time too short (8 hours for average size pools, more for large pools)
- Salt level too low (below 2400 ppm, Check Salt LED on). Plumbing.......................................................................................11
- Salt level too high (High Salt LED on).
- Very warm pools increase chlorine demand--increase Output %, or filter run time. Wiring............................................................................................12
- Cold water (below 50ºF) causes Aqua Rite to stop generating (Generating LED flash-
ing).
- Excessive scaling on cell.
- High level of Nitrogen in pool water. TROUBLESHOOTING
- "Yellow Out" or similar treatment recently used. Some yellow algae treatments will Troubleshooting.........................................................................14
use chlorine at a very high rate and deplete the residual free chlorine. Manually shock
the pool if indicated in the directions on the algae treatment. It still may be a matter of
days before the pool returns to "normal" and chlorine tests will show the desired 1-
3ppm free chlorine reading.
WARRANTY
9. "-Pcb-" displayed and all 4 red/yellow LEDs are illuminated. Warranty......................................................................................16
A possible Printed Circuit Board fault has been detected. Call for
service.

15
OPERATION Polaris - Attach wires to proper screw terminals as shown below. Note that screw
terminal "1" is marked on the Polaris PCB.
The Aqua Rite is an automatic chlorine generation system for pool or spa sanitation.
®

The operation requires a low concentration of salt (sodium chloride) in the pool water. note
marked
These levels are low enough that it normally will not be tasted. The Aqua Rite automati- GRN 4
black
1 on PCB

cally sanitizes your pool by converting the salt into free chlorine which kills bacteria and YEL 3
yellow

algae in the pool. Chlorine will revert back to sodium chloride after killing bacteria.
Aqua Rite BLK 2
green Eos
These reactions will continuously recycle virtually eliminating the need to add sanitiz- RED 1
red

ing chemicals to your pool. The only time you may need to add more salt to the pool is
when water is replenished due to backwashing, draining, or splashing (not evapora-
tion).

The Aqua Rite is designed to handle the purification needs of most residential swim- TROUBLESHOOTING
ming pools up to 40,000 gallons (150,000 liters), or the needs of most commercial pools Visit www.goldlinecontrols.com for helpful information on operation, maintenance and
up to 25,000 gallons (95,000 liters). Check local codes for other restrictions. The actual troubleshooting your Aqua Rite® Electronic Chlorine Generator.
amount of chlorination required to properly sanitize a pool varies due to bather load,
rainfall, temperature, and the pool's cleanliness. Diagnostic Displays
Sequential pushes of the small "diagnostic" button next to the LCD display will cause
NOTE: Hayward does not recommend using the Aqua Rite to generate bromine. the Aqua Rite to display the following information:
Aqua Rite chlorine generators operating with software version 1.50 or later are designed 1. Pool temperature (xx degrees Fahrenheit or Celsius)
to use one of 3 different chlorinator cells that are available from your authorized Hay- 2. Cell voltage (xx.x volts)
ward dealer. These cells are not included with the Aqua Rite and must be purchased 3. Cell current (x.xx amps)
before installation. Choose the appropriate cell based on the size of your pool. The 4. Desired Output % ("0P" -- "100P" depending on knob position or input from remote
models are shown below: pool automation controller)
5. Instant salinity ( -xxxx ppm or -x.xx grams/Liter)
T-CELL-15- for pools up to 40,000 gallons 6. Product name sent to the pool automation control display ("AL-0" which signifies
T-CELL-9 - for pools up to 25,000 gallons "Aqua Rite")
T-CELL-3 - for pools up to 15,000 gallons 7. Software revision level (r1.xx)
8. Chlorinator cell type (t-3, t-5, t-9, t-15)
Note that the installation and mounting requirements are the same for all models.
On the 9th push of the button the display will revert back to the default salt display.
NOTE: Before installing this product as part of a saline water purification system in a Also, if the button is not pushed for 30 seconds, the display will revert back to the
pool or spa using natural stone for coping or for immediately adjacent patios/decking, a standard salt display.
qualified stone installation specialist should be consulted regarding the appropriate
type, installation, sealant (if any) and maintenance of stone used around a saline pool Common Problems and Solutions
with electronic chlorine generator in your particular location and circumstances. 1. "Power" LED not on
Check to make sure either 120VAC or 240VAC input power is connected to the proper
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged espe- screw terminals at the Aqua Rite control. Verify input voltage with a voltmeter. If there
cially in arid regions where pool water is subject to excessive evaporation and is not is input power, the fuse may have blown. The Aqua Rite is protected by a 20 amp mini
commonly diluted with fresh water. Dry acid can cause a buildup of by-products that ATO fuse located on the circuit board above the cell connector.
can damage your chlorinator cell.
2. "Generating" LED flashing
The temperature of the pool water is too high or low to operate. You can override this by
switching the main switch to SUPER CHLORINATE. The Aqua Rite will run at maximum
output for the remainder of the current pump cycle or 24 hours, whichever comes first.

3. "No Flow" LED illuminated


The Aqua Rite has sensed a no flow condition and has stopped generating chlorine.
Check that the flow switch is plugged into the connector on the bottom of the control
unit and that the wire is not cut or damaged. Make sure you have at least 12" of straight
pipe before the flow switch. If there is adequate flow and the LED is still on, check that
the arrows on the flow switch (on top of hex) are pointing in the direction of flow.

1 14
Input power for use with Hayward/Goldline, Pentair and Water Chemistry
Polaris controls The table below summarizes the levels that are recommended by The Association of
Wire the Aqua Rite® DIRECTLY to 120/240VAC power (not through timer or relay). Pool and Spa Professionals (APSP). The only special requirements for the Aqua Rite
are the salt level and stabilizer. It is important to maintain these levels in order to
HAYWARD/GOLDLINE,
PENTAIR prevent corrosion or scaling and to ensure maximum enjoyment of the pool. Test your
or water periodically. Your Authorized Aqua Rite Dealer (AARD) or most pool stores can
POLARIS
AQUA RITE AQUA RITE
provide you with the chemicals and procedures to adjust the water chemistry. Be sure
(240 VAC) (120 VAC) to tell the pool store that you are using an Aqua Rite chlorine generator.

SUBPANEL
GND GND

PCB PCB

NEUTRAL
BONDING BONDING
GROUND LOOP LOOP

Optional Hayward/Goldline, Pentair and Polaris controls:


The Hayward/Goldline, Pentair and Polaris controls use a 4 wire connection to commu-
nicate to the Aqua Rite and can be wired up to 500' apart. Any outdoor rated 4 conductor
cable can be used. Refer to each manufacturer's instructions and the wiring diagrams
below for proper wiring connection to the Aqua Rite. NOTE: There must be only 1
"primary" unit. All other Aqua Rite units must be configured as "secondary".
Saturation index
4 GREEN The saturation index (Si) relates to the calcium and alkalinity in the water and is an
3
2
YELLOW
BLACK Jumper Installed
Jumper Removed
indicator of the pool water "balance". Your water is properly balanced if the Si is 0 ±.2.
1 RED For Primary
(Factory Default)
For Secondary(s) If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved into
the water. If the Si is above +0.2, scaling and staining will occur. Use the chart below to
determine the saturation index.
Additional
Aqua Rite(s)
(if required)
Si = pH + Ti + Ci + Ai - 12.1
Hayward/Goldline, Aqua Rite Aqua Rite
(Secondary) Calcuim Total
Pentair (Primary) ºC ºF Ti Ci Ai
Hardness Alkalinity
or Polaris
Power Center 12 53 .3 75 1.5 75 1.9
100 1.6 100 2.0
16 60 .4
125 1.7 125 2.1
Hayward/Goldline - Attach wires to proper screw terminals as shown below. 19 66 .5 150 1.8 150 2.2
200 1.9 200 2.3
green
GRN 24 76 .6
GRN 4 4 250 2.0 250 2.4
YEL 3
yellow
3 YEL Pro Logic 29 84 .7 300 2.1 300 2.5
Aqua Rite BLK 2
black
2 BLK Aqua Logic 400 2.2 400 2.6
1
red
RED 34 94 .8
RED 1 600 2.4 600 2.8
39 103 .9 800 2.5 800 2.9

Pentair - Attach wires to opposite numbered screw terminals as shown below. Note How to use: Measure pool pH, temperature, calcium hardness,
and total alkalinity. Use the chart above to determine Ti, Ci,and
that the colors marked on the Pentair PCB do not match the Aqua Rite. Ai from your measurements. Insert values of pH, Ti, Ci and Ai
into the above equation. If Si equals .2 or more, scaling and
staining may occur. If Si equals -.2 or less corrosion or irritation
marking on PCB
(Colors Do Not Match) green may occur.
GRN 4 1 BLK / GND -.2 0 .2
yellow CORROSIVE SCALING
Aqua Rite YEL 3
black
2 GRN / -DT Intellitouch
BLK 2 3 YEL / +DT
red
RED 1 4 RED / +15 OK

13 2
Salt Level Wiring
Use the chart on page 4 to determine how much salt in pounds or (Kgs) need to be added Power must be shut off at the circuit breaker before performing any wiring. Be sure to
to reach the recommended levels. Use the equations below (measurements are in feet/ follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite® must
gallons and meters/liters) if pool size is unknown. be properly grounded and bonded.

Input Power For stand alone operation:


Wire the Aqua Rite to the LOAD SIDE of the filter pump timer. It is very important that
Gallons Liters the Aqua Rite is powered only when the pump is running.
(pool size in feet) (pool size in meters)
Length x Width x Length x Width x Refer to the wiring label on the Aqua Rite as well as the diagram below to determine
Rectangular correct wiring connections. The Aqua Rite is shipped from the factory with the configu-
Average Depth x 7.5 Average Depth x 1000
ration jumpers in 240VAC position. If using 120VAC, move the jumpers as shown below.
Diameter x Diameter x Diameter x Diameter x For Canadian models, the Aqua Rite shall be connected to a circuit protected by a class
Round
Average Depth x 5.9 Average Depth x 785 A ground fault interrupter. Be sure to connect the ground wire to the green ground
Length x Width x Length x Width x screw terminal located on the bottom of the enclosure.
Oval Average Depth x 6.7 Average Depth x 893
TYPICAL 240 VAC WIRING 120 VAC
TIMECLOCK AQUA AQUA
The ideal salt level is between 2700-3400 ppm (parts per million) with 3200 ppm being RITE RITE
optimal. If the level is low, determine the number of gallons in the pool and add salt SUBPANEL
according to the chart on page 4. A low salt level will reduce the efficiency of the Aqua GND GND

Rite® and result in low chlorine production. A high salt level can cause the Aqua Rite® LINE LOAD
to shutdown and may begin to give a salty taste to your pool (generally, the salt will
begin to be tasted at a level of about 3500-4000 ppm). The salt in your pool/spa is PCB PCB
constantly recycled and the loss of salt throughout the swimming season should be GROUND
small. This loss is due primarily to the addition of water because of splashing, BONDING
LUG
backwashing, or draining (because of rain). Salt is not lost due to evaporation.
IMPORTANT:
Type of Salt to Use PUMP
BONDING
MOVE JUMPERS
TO POSITIONS SHOWN
It is important to use only sodium chloride (NaCl) salt that is greater than 99% pure. This LOOP

is common food quality or water softener salt and is usually available in 40-80 lb. bags Note: Wire the pump directly to the timeclock--do not use the Aqua Rite as a junction box.
labeled "Coarse Solar Salt". It is also acceptable to use water conditioning salt pellets,
however, it will take longer for them to dissolve. Do not use rock salt, salt with yellow Bonding:
prussiate of soda, salt with anti-caking additives, or iodized salt. A lug used for bonding is attached to the bottom of the Aqua Rite enclosure (see
diagram below). The Aqua Rite must be bonded with an 8 AWG copper wire (6 AWG
How to Add or Remove Salt Canada) to the pool bonding system.
For new plaster pools, wait 10-14 days before adding salt to allow the plaster to cure.
Turn the circulating pump on and add salt directly into the pool. Brush the salt around Electrolytic Cell and Flow Switch:
to speed up the dissolving process--do not allow salt to pile up on the bottom of the The electrolytic cell and flow switch cables are terminated with connectors which plug
pool. Run the filter pump for 24 hours with the suction coming from the main drain (use into the Aqua Rite, for easy attachment and removal. The door of the Aqua Rite must be
pool vac if there is no main drain) to allow the salt to evenly disperse throughout the open to access the cell cable connector. The flow switch plugs into a connector (similar
pool. The salt display may take 24 hours to respond to the change in salt concentration. to a telephone jack) located outside, on the bottom of the enclosure. Refer to the
diagram below for the location of these connections.
The only way to lower the salt concentration is to partially drain the pool and refill with Flow switch connector
Cutout for
cell cable
fresh water.

Always check stabilizer (cyanuric acid), when checking salt. These levels will most
likely decline together. Use the chart on page 5 to determine how much stabilizer must
be added to raise the level to 80 ppm.

Bonding lug to
pool bonding system

3 12
plumbing.

Flow Switch:
Plumbing

12”
min

3
1

operating the spa only.

11
local potable water supply. Consult local plumbing codes.

12”
min
2

4
chased separately. Refer to page 1 for information about available chlorinator cells.

(located on top of gray hex) points in the direction of water flow.


overchlorination of the spa during "spa only" operation. Never use configuration #4.

before (upstream) the flow switch. If the switch is plumbed after the
IMPORTANT: There must be at least a 12" (25cm) straight pipe run

Electrolytic Cell: Install using the unions provided. Tighten unions BY HAND for a
ensure proper operation, verify that the arrow on the flow switch
#1 shows the flow switch can also be in front of the cell. Configurations #2 and #3 allow
etc.). The electrolytic cell and flow switch tee fitting are designed to be plumbed into 2"
The Aqua Rite is packaged with a flow switch and cell unions. The cell must be pur-

watertight seal. For pool/spa combination systems with spillover,


(51mm) PVC pipe. Adapters (not included) can be used for systems with 1½" (38 mm)

for chlorination of both the pool and spa during spa spillover operation, but prevent
preferred installation is after (downstream) all the pool equipment (filter, heater, solar,

pool and spa during spillover but preventing overchlorination when


For proper plumbing, refer to the overview diagram on page 9. Alternate configurations

cell, the cell can by counted as the 12" (25cm) of straight pipe. To

use configurations #2 or #3 above to allow chlorination of both the


The flow switch and cell should be plumbed in the return line to the pool/spa. The
Ensure that the Aqua Rite® installation does not constitute a cross connection with the

POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM


Current salt Gallons and (Liters) of Pool/Spa water
level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000
ppm (30,000) (37,500) (45000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000) (97,500) (105,000) (112,500)(120,000) (127,500)(135,000)(142,500)(150,000)
213 267 320 373 427 480 587 640 693 747 800 854 907 960 1067
0 (97) (194)
(121) (145) (170) (218) (242) (267) (291) (315) (339) (364) (388) (412) (436) (460) (484)

200
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000
(91) (114) (136) (159) (182) (205) (227) (250) (273) (295) (318) (341) (363) (385) (408) (430) (453)
187 233 280 327 373 420 467 513 560 607 653 700 747 793 840 887 933
400 (85) (106) (127) (148) (170) (191) (212) (233) (255) (276) (297) (318) (339) (360) (382) (403) (424)
173 217 260 303 347 390 433 477 520 563 607 650 693 737 780 823 867
600 (79) (98) (118) (138) (158) (177) (197) (217) (236) (256) (276) (297) (317) (337) (358) (378) (398)
160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 800
800 (73) (91) (109) (127) (145) (164) (182) (200) (218) (236) (255) (273) (291) (310) (328) (346) (364)
147 183 220 257 293 330 367 403 440 477 513 550 587 623 660 697 733
1000 (67) (83) (100) (117) (133) (150) (167) (183) (200) (217) (233) (250) (267) (283) (300) (317) (333)
133 167 200 233 267 300 333 367 400 433 467 500 533 567 600 633 667
1200 (61) (76) (91) (106) (121) (136) (152) (167) (182) (197) (212) (227) (243) (258) (274) (289) (304)
120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600
1400 (55) (68)
4 (82) (95) (109) (123) (136) (150) (164) (177) (191) (205) (218) (232) (246) (259) (263)
107 133 160 187 213 240 267 293 320 347 373 400 427 453 480 507 533
1600
(48) (61) (73) (85) (97) (109) (121) (133) (145) (158) (170) (182) (195) (207) (219) (231) (243)
93 117 140 163 187 210 233 257 280 303 327 350 373 397 420 443 467
1800 (42) (53) (64) (74) (85) (95) (106) (117) (127) (138) (148) (159) (169) (180) (190) (201) (211)
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
2000 (36) (45) (55) (64) (73) (82) (91) (100) (109) (118) (127) (136) (145) (154) (163) (172) (181)

2200 67 83 100 117 133 150 167 183 200 217 233 250 267 283 300 317 333
(30) (38) (45) (53) (61) (68) (76) (83) (91) (98) (106) (114) (121) (129) (137) (144) (152)
53 67 80 93 107 120 133 147 160 173 187 200 213 227 240 253 267
2400 (24) (30) (36) (42) (48) (55) (61) (67) (73) (79) (85) (91) (98) (104) (110) (117) (123)

2600 40 50 60 80 90 100 110 120 130 140 150 160 170 180 190 200
(18) (23) (27) (32) (36) (41) (45) (50) (55) (59) (64) (68) (73) (77) (81) (86) (90)
2800 27 33 40 47 53 60 67 73 80 87 93 100 107 113 120 127 133
(12) (15) (18) (21) (24) (27) (30) (33) (36) (39) (42) (45) (48) (51) (54) (57) (60)

3000 13 17 20 23 27 30 33 37 40 43 47 50 53 57 60 63 67
(6) (8) (9) (11) (12) (14) (15) (17) (18) (20) (21) (23) (24) (26) (27) (29) (30)
3200 Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal
3400 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK
3600+ Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute
POUNDS and (Kg) OF STABILIZER (CYANURIC ACID) NEEDED FOR 80 PPM
Gallons and (Liters) of Pool/Spa water
Current
Stabilizer 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000
Level (ppm) (30000) (37500) (45000) (52500) (60000) (67500) (75000) (82500) (90000) (97500) (105000) (112500)(120000) (127500)(135000) (142500) (150000)
5.3 6.7 8.0 9.4 10.7 12.0 13.4 14.7 16.0 18.7 20.0 21.3 22.7 25.3 26.7
0 ppm (3.6) (4.3) (3.6) (4.3) (4.9) (5.4) (6.1) (6.7) (7.3) (8.5) (9.1) (9.7) (10.3) (11.5) (12.0)
4.7 5.8 7.0 8.2 9.4 10.5 11.7 12.9 14.0 15.2 16.4 17.2 18.7 19.8 21.0 22.2 23.3
10 ppm (3.2) (3.7) (3.2) (3.7) (4.3) (4.8) (5.3) (5.9) (6.4) (6.9) (7.4) (8.0) (8.5) (9.0) (9.5) (10.0) (10.5)

20 ppm 4.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 18.0 19.0 20.0
(2.7) (2.7) (3.2) (3.6) (2.2) (4.5) (5.0) (5.4) (5.9) (6.4) (6.8) (7.2) (8.1) (8.6) (9.0)
3.3 4.2 5.0 5.9 6.7 7.5 8.4 9.2 10.0 10.8 11.7 12.5 13.3 14.2 15.0 15.8 16.7

5
30 ppm (4.5) (4.9) (5.2) (5.6) (6.0) (6.3) (6.7) (7.1) (7.5)
(2.3) (2.7) (2.3) (2.7) (3.0) (3.4) (3.8) (4.2)
40 ppm 2.7 3.3 4.0 4.7 5.4 6.0 6.7 7.4 8.0 8.7 9.3 10.0 10.7 12.0 12.7 13.3
(1.8) (2.1) (1.8) (2.1) (2.4) (2.7) (3.0) (3.3) (3.6) (3.9) (4.2) (4.5) (4.8) (5.4) (5.7) (6.0)
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0
50 ppm (1.4) (1.6) (1.4) (1.6) (1.8) (2.0) (2.3) (2.5) (2.7) (2.9) (3.2) (3.4) (3.6) (3.9) (4.1) (4.3) (4.5)
1.3 1.7 2.0 2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0 5.3 5.7 6.3 6.7
60 ppm (.91) (1.1) (.91) (1.1) (1.2) (1.5) (1.7) (1.8) (2.0) (2.1) (2.3) (2.4) (2.6) (2.8) (3.0)
(1.4)
70 ppm 0.7 0.8 1.0 1.2 1.4 1.5 1.7 1.8 2.0 2.2 2.3 2.5 2.7 2.8 3.0 3.2 3.3
(.45) (.54) (.45) (.54) (.64) (.68) (.77) (.82) (.91) (1.0) (1.1) (1.2) (1.2) (1.3) (1.3) (1.4) (1.5)
80 ppm 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
POWER
120/240 VAC

to the Aqua Rite system.


POOL
FROM
SPA
FROM

Preparing Pool/Spa Water

Rite inside a panel or tight enclosed area.

10
more, if local codes require) from the pool/spa.
Mounting the Aqua Rite Control
INSTALLATION

G
AQUA

RITE

LDLINE
CONTROLS INC.

TO
Aqua Rite

POOL
Installation must be performed in accordance with Local and NEC codes.

TO
SPA

the box), it is important not to block the four sides of the control. Do not mount Aqua
anced BEFORE activating the Aqua Rite®. NOTE: If the pool does not have new water,

The control is designed to mount vertically on a flat surface with the knockouts facing
Refer to page 1 for recommended chemical levels. The pool's chemistry must be bal-

The Aqua Rite is contained in a raintight enclosure that is suitable for outdoor mount-
to the pool, per manufacturer's instructions. This ensures a quick, troublefree transfer

downward. Because the enclosure also acts as a heat sink (disperses heat from inside
add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of non-copper based algaecide

ing. The control must be mounted a minimum of 5 ft. (2 meters) horizontal distance (or
The Aqua Rite electrolytic cell has a self cleaning feature incorporated into the elec-
Controls
tronic control’s logic. In most cases this self cleaning action will keep the cell working Main Switch
at optimum efficiency. In areas where water is hard (high mineral content) and in pools AUTO: For normal operation, the Main Switch should be left in the AUTO position.
where the water chemistry has been allowed to get "out of balance", the cell may require In this position the Aqua Rite will produce chlorine according to the "Desired Out-
periodic cleaning. The "Inspect Cell" LED will indicate if cell efficiency is decreased and put %" adjustment setting for the entire filtering/pumping cycle.
servicing is necessary. If the "Inspect Cell" LED remains on after a thorough cleaning,
the cell may be worn and require replacement. SUPER CHLORINATE: When you have an abnormally high bather load, a large
amount of rain, a cloudy water condition, or any other condition which needs a large
Servicing and Cleaning the Aqua Rite cell amount of purification to be introduced, put the Main Switch in the SUPER CHLO-
Turn off power to the Aqua Rite before removing the electrolytic cell. Once removed, RINATE position. This electronically “super chlorinates” (shocks) the water for 24
look inside the cell and inspect for scale formation (light colored crusty or flaky depos- hours (filter pump must be on during this time) or until the power has been turned
its) on the plates and for any debris which has passed through the filter and caught on off, whichever comes first. At the end of the super chlorinate time, be sure to put the
the plates. If no deposits are visible, reinstall. If deposits are seen, use a high pressure switch back into the AUTO position.
garden hose and try to flush the scale off. If this is not successful, use a plastic or wood
tool (do not use metal as this will scratch the coating off the plates) and scrape deposits OFF: The OFF position prevents the Aqua Rite from energizing the electrolytic cell.
off of plates. Note that a buildup on the cell indicates that there is an unusually high In this position there is no chlorine generation. NOTE: To service any of the pool
calcium level in the pool (old pool water is usually the cause). If this is not corrected, equipment or the Aqua Rite, turn the power off at the circuit breaker.
you may to have to periodically clean the cell. The simplest way to avoid this is to bring
the pool chemistry to the recommended levels as specified. Indicator LED's
POWER When illuminated, the Aqua Rite has input power.
Mild Acid Washing: Use only in severe cases where flushing and scraping will not
remove the majority of deposits. To acid wash, turn off power to Aqua Rite. Remove cell GENERATING This LED is on steady during normal operation. When flashing, the
from piping. In a clean plastic container, mix a 4:1 solution of water to muriatic acid (one pool water is too hot or cold to operate.
gallon of water to one quart of muriatic acid). ALWAYS ADD ACID TO WATER -
NEVER ADD WATER TO ACID. Be sure to wear rubber gloves and appropriate eye SUPER CHLORINATE Illuminates during super-chlorination. See description
protection. The level of the solution in the container should just reach the top of the cell above.
so that the wire harness compartment is NOT submerged. It may be helpful to coil the
wiring before immersing the cell. The cell should soak for a few minutes and then rinse REMOTELY CONTROLLED When illuminated, indicates that a remote pool auto-
with a high pressure garden hose. If any deposits are still visible, repeat soaking and mation control (Hayward/Goldline Pro Logic, Pentair Intellitouch, Polaris Eos, etc.)
rinsing. Replace cell and inspect again periodically. is controlling the Aqua Rite--the main switch and "Desired Output %" adjustment
are inactive. When flashing, the Pro Logic, Intellitouch or Eos is in SERVICE or
Winterizing TIME-OUT mode and the Main Switch and "Desired Output %" adjustment are
The Aqua Rite electrolytic cell and flow detection switch will be damaged by freezing active.
water just as your pool plumbing would. In areas of the country which experience
severe or extended periods of freezing temperatures, be sure to drain all water from the NO FLOW When illuminated, the flow switch has detected no water flowing and
pump, filter, and supply and return lines before any freezing conditions occur. The the Aqua Rite has stopped generating chlorine. A flashing LED indicates a 15-60
electronic control is capable of withstanding any winter weather and should not be second time delay period.
removed.
CHECK SALT When flashing, the salt level is low (below 2700 ppm) and Aqua Rite
is generating at low efficiency. When illuminated steady, the salt level is too low and
Spring Start-up Aqua Rite has shut down. Before adding large quantities of salt, it is advisable to
DO NOT turn the Aqua Rite on, until the pool water chemistry has been brought to the have your salt level professionally checked.
proper levels. This information can be found on page 1.
HIGH SALT When illuminated, the salt level is too high and Aqua Rite has shut
down.

INSPECT CELL A flashing indicator signifies that either the cell efficiency is re-
duced or that it is time for regularly scheduled cell inspection. In either case, inspect
cell and clean if necessary. When illuminated steady, cell efficiency is greatly re-
duced and the Aqua Rite has stopped producing chlorine. Inspect, clean or replace
if necessary.

9 6
To Set Turbo Cell Type Operation
Before operation, the Aqua Rite must be configured for the chlorinator cell that will be Assuming that the water chemical levels are in the recommended range, there are three
used. Refer to the following information and steps below to set the Turbo cell type. factors that you can control which directly contribute to the amount of chlorine the
Aqua Rite will generate:
"t-3" = T-CELL-3, GLX-CELL-3-W
"t-5" = GLX-CELL-5, GLX-CELL-5-W 1. filter time each day (hours)
"t-9 = T-CELL-9, GLX-CELL-9-W 2. the "Desired Output %" setting
"t-15" = T-CELL-15, GLX-CELL-15-W 3. the amount of salt in the pool
1. Slide the Main Switch to the "Auto" position. The filter pump timer should be set so that all of the water in the pool passes through
2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the filter each day. For pools with high chlorine demand, the timer may have to be set
the factory default). If the desired cell type is displayed skip to step 4. longer to generate enough chlorine.
3. To change to a different cell type, slide the Main Switch from "Auto" to "Super
Chlorinate" and back to "Auto". Repeat this process until the desired cell type is To find the optimum "Desired Output %" setting, start at approximately 50%. Test the
displayed. chlorine level every few days and adjust the dial up or down accordingly. It usually
4. Push the Diagnostic button to exit. takes 2-3 adjustments to find the ideal setting for your pool/spa and after that, it should
only take minor, infrequent adjustments. Because the chlorine demand of the pool
increases with temperature, most people find they have to adjust the dial up at the peak
Desired Output %" adjustment knob of the summer and down during the colder periods. The Aqua Rite automatically stops
The "Desired Output %" adjustment knob is located in the lower center of the Aqua Rite generating when the pool water temperatures drops below 50ºF. This is usually not a
control panel. This setting is used to control the amount of chlorine the Aqua Rite problem because bacteria and algae stop growing at this temperature. You can override
generates. Raise this setting to increase chlorine level and lower it to decrease chlorine this low temperature cutoff by switching to SUPER CHLORINATE for a day.
level. Note: The "Desired Output %" adjustment will not function when the Aqua Rite
is being controlled by a remote pool automation control. NOTE: After the ideal "Desired Output %" setting has been found, you may need to
raise the setting when the pool water temperature increases significantly, when there is
Salt Display higher than normal bather load or when your chlorinator cell ages. You may need to
Refer to the Water Chemistry section for recommended salt levels as well as how to add/ lower the setting when the pool water temperature decreases significantly or there are
remove salt. The Salt Display shows the average salt level of the pool water. The long periods of inactivity.
factory default display is in English units (ppm). If Metric units (grams per liter) are
preferred, follow the procedure under Temperature Display. Prevent over-chlorination during cold weather: Check chlorine levels periodically. Most
pools require less chlorine during cold weather and the “Desired Output %” should be
Temperature Display lowered accordingly.
The Temperature Display shows the current temperature of the pool water. The factory
default display is in ºF. Both the Temperature Display and the Salt Display can be When connected to a pool automation control (Hayward/Goldline Pro Logic, Pentair
programmed to display in Metric units. To display temperature in ºC and salt level in g/ Intellitouch or Polaris Eos):
l, perform the following steps: The Aqua Rite is designed to operate with all pool automation controls. The Pro Logic,
Intellitouch or Eos can fully control the function of the Aqua Rite chlorinator in addition
1. Slide the Main Switch to the "Auto" position. to the other pool equipment. The "Remotely Controlled" LED on the Aqua Rite chlori-
2. Push the Diagnostic button repeatedly until "ºF" appears on the display. nator will be illuminated when the automation control is activated. Adjustment of the
3. Slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto". Aqua Rite "Desired Output %" and also Superchlorination can be controlled from the
4. Push the Diagnostic button to exit. pool automation display/keypad. Refer to the pool automation control instructions for
more information. The Aqua Rite salt display and LED indicators operate as normal, but
Instant Salinity the main switch and "Desired Output %" dial are disabled.
The Instant Salinity display is the measured salt level of the pool water at that moment.
If salt has recently been added, the Instant Salinity may show the change while the Salt Maintaining the Aqua Rite System
Display (average salt level) may take some time before the changes can be seen. Under To maintain maximum performance, it is recommended that you open and visually in-
these circumstances, you may want to "update" the Salt Display to the new Instant spect the cell every 3 months or after cleaning your filter. The Aqua Rite® will remind
Salinity value. This action will clear the Salt Display and substitute the Instant Salinity you to do this by flashing the "Inspect Cell" LED after approximately 500 hours of
value. To do this, follow the steps below. operation. After you inspect the cell (and clean, if necessary) press the small "diagnos-
tic" button next to the display for 3 seconds to stop the flashing "Inspect Cell" LED and
1. Slide the Main Switch to the "Auto" position. start the timer for the next 500 hours.
2. Push the Diagnostic button repeatedly until "-xxxx ppm" appears on the display.
3. Slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto".
4. Push the Diagnostic button to exit.

7 8
To Set Turbo Cell Type Operation
Before operation, the Aqua Rite must be configured for the chlorinator cell that will be Assuming that the water chemical levels are in the recommended range, there are three
used. Refer to the following information and steps below to set the Turbo cell type. factors that you can control which directly contribute to the amount of chlorine the
Aqua Rite will generate:
"t-3" = T-CELL-3, GLX-CELL-3-W
"t-5" = GLX-CELL-5, GLX-CELL-5-W 1. filter time each day (hours)
"t-9 = T-CELL-9, GLX-CELL-9-W 2. the "Desired Output %" setting
"t-15" = T-CELL-15, GLX-CELL-15-W 3. the amount of salt in the pool
1. Slide the Main Switch to the "Auto" position. The filter pump timer should be set so that all of the water in the pool passes through
2. Push the Diagnostic button repeatedly until "t-xx" appears on the display ("t-15" is the filter each day. For pools with high chlorine demand, the timer may have to be set
the factory default). If the desired cell type is displayed skip to step 4. longer to generate enough chlorine.
3. To change to a different cell type, slide the Main Switch from "Auto" to "Super
Chlorinate" and back to "Auto". Repeat this process until the desired cell type is To find the optimum "Desired Output %" setting, start at approximately 50%. Test the
displayed. chlorine level every few days and adjust the dial up or down accordingly. It usually
4. Push the Diagnostic button to exit. takes 2-3 adjustments to find the ideal setting for your pool/spa and after that, it should
only take minor, infrequent adjustments. Because the chlorine demand of the pool
increases with temperature, most people find they have to adjust the dial up at the peak
Desired Output %" adjustment knob of the summer and down during the colder periods. The Aqua Rite automatically stops
The "Desired Output %" adjustment knob is located in the lower center of the Aqua Rite generating when the pool water temperatures drops below 50ºF. This is usually not a
control panel. This setting is used to control the amount of chlorine the Aqua Rite problem because bacteria and algae stop growing at this temperature. You can override
generates. Raise this setting to increase chlorine level and lower it to decrease chlorine this low temperature cutoff by switching to SUPER CHLORINATE for a day.
level. Note: The "Desired Output %" adjustment will not function when the Aqua Rite
is being controlled by a remote pool automation control. NOTE: After the ideal "Desired Output %" setting has been found, you may need to
raise the setting when the pool water temperature increases significantly, when there is
Salt Display higher than normal bather load or when your chlorinator cell ages. You may need to
Refer to the Water Chemistry section for recommended salt levels as well as how to add/ lower the setting when the pool water temperature decreases significantly or there are
remove salt. The Salt Display shows the average salt level of the pool water. The long periods of inactivity.
factory default display is in English units (ppm). If Metric units (grams per liter) are
preferred, follow the procedure under Temperature Display. Prevent over-chlorination during cold weather: Check chlorine levels periodically. Most
pools require less chlorine during cold weather and the “Desired Output %” should be
Temperature Display lowered accordingly.
The Temperature Display shows the current temperature of the pool water. The factory
default display is in ºF. Both the Temperature Display and the Salt Display can be When connected to a pool automation control (Hayward/Goldline Pro Logic, Pentair
programmed to display in Metric units. To display temperature in ºC and salt level in g/ Intellitouch or Polaris Eos):
l, perform the following steps: The Aqua Rite is designed to operate with all pool automation controls. The Pro Logic,
Intellitouch or Eos can fully control the function of the Aqua Rite chlorinator in addition
1. Slide the Main Switch to the "Auto" position. to the other pool equipment. The "Remotely Controlled" LED on the Aqua Rite chlori-
2. Push the Diagnostic button repeatedly until "ºF" appears on the display. nator will be illuminated when the automation control is activated. Adjustment of the
3. Slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto". Aqua Rite "Desired Output %" and also Superchlorination can be controlled from the
4. Push the Diagnostic button to exit. pool automation display/keypad. Refer to the pool automation control instructions for
more information. The Aqua Rite salt display and LED indicators operate as normal, but
Instant Salinity the main switch and "Desired Output %" dial are disabled.
The Instant Salinity display is the measured salt level of the pool water at that moment.
If salt has recently been added, the Instant Salinity may show the change while the Salt Maintaining the Aqua Rite System
Display (average salt level) may take some time before the changes can be seen. Under To maintain maximum performance, it is recommended that you open and visually in-
these circumstances, you may want to "update" the Salt Display to the new Instant spect the cell every 3 months or after cleaning your filter. The Aqua Rite® will remind
Salinity value. This action will clear the Salt Display and substitute the Instant Salinity you to do this by flashing the "Inspect Cell" LED after approximately 500 hours of
value. To do this, follow the steps below. operation. After you inspect the cell (and clean, if necessary) press the small "diagnos-
tic" button next to the display for 3 seconds to stop the flashing "Inspect Cell" LED and
1. Slide the Main Switch to the "Auto" position. start the timer for the next 500 hours.
2. Push the Diagnostic button repeatedly until "-xxxx ppm" appears on the display.
3. Slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto".
4. Push the Diagnostic button to exit.

7 8
The Aqua Rite electrolytic cell has a self cleaning feature incorporated into the elec-
Controls
tronic control’s logic. In most cases this self cleaning action will keep the cell working Main Switch
at optimum efficiency. In areas where water is hard (high mineral content) and in pools AUTO: For normal operation, the Main Switch should be left in the AUTO position.
where the water chemistry has been allowed to get "out of balance", the cell may require In this position the Aqua Rite will produce chlorine according to the "Desired Out-
periodic cleaning. The "Inspect Cell" LED will indicate if cell efficiency is decreased and put %" adjustment setting for the entire filtering/pumping cycle.
servicing is necessary. If the "Inspect Cell" LED remains on after a thorough cleaning,
the cell may be worn and require replacement. SUPER CHLORINATE: When you have an abnormally high bather load, a large
amount of rain, a cloudy water condition, or any other condition which needs a large
Servicing and Cleaning the Aqua Rite cell amount of purification to be introduced, put the Main Switch in the SUPER CHLO-
Turn off power to the Aqua Rite before removing the electrolytic cell. Once removed, RINATE position. This electronically “super chlorinates” (shocks) the water for 24
look inside the cell and inspect for scale formation (light colored crusty or flaky depos- hours (filter pump must be on during this time) or until the power has been turned
its) on the plates and for any debris which has passed through the filter and caught on off, whichever comes first. At the end of the super chlorinate time, be sure to put the
the plates. If no deposits are visible, reinstall. If deposits are seen, use a high pressure switch back into the AUTO position.
garden hose and try to flush the scale off. If this is not successful, use a plastic or wood
tool (do not use metal as this will scratch the coating off the plates) and scrape deposits OFF: The OFF position prevents the Aqua Rite from energizing the electrolytic cell.
off of plates. Note that a buildup on the cell indicates that there is an unusually high In this position there is no chlorine generation. NOTE: To service any of the pool
calcium level in the pool (old pool water is usually the cause). If this is not corrected, equipment or the Aqua Rite, turn the power off at the circuit breaker.
you may to have to periodically clean the cell. The simplest way to avoid this is to bring
the pool chemistry to the recommended levels as specified. Indicator LED's
POWER When illuminated, the Aqua Rite has input power.
Mild Acid Washing: Use only in severe cases where flushing and scraping will not
remove the majority of deposits. To acid wash, turn off power to Aqua Rite. Remove cell GENERATING This LED is on steady during normal operation. When flashing, the
from piping. In a clean plastic container, mix a 4:1 solution of water to muriatic acid (one pool water is too hot or cold to operate.
gallon of water to one quart of muriatic acid). ALWAYS ADD ACID TO WATER -
NEVER ADD WATER TO ACID. Be sure to wear rubber gloves and appropriate eye SUPER CHLORINATE Illuminates during super-chlorination. See description
protection. The level of the solution in the container should just reach the top of the cell above.
so that the wire harness compartment is NOT submerged. It may be helpful to coil the
wiring before immersing the cell. The cell should soak for a few minutes and then rinse REMOTELY CONTROLLED When illuminated, indicates that a remote pool auto-
with a high pressure garden hose. If any deposits are still visible, repeat soaking and mation control (Hayward/Goldline Pro Logic, Pentair Intellitouch, Polaris Eos, etc.)
rinsing. Replace cell and inspect again periodically. is controlling the Aqua Rite--the main switch and "Desired Output %" adjustment
are inactive. When flashing, the Pro Logic, Intellitouch or Eos is in SERVICE or
Winterizing TIME-OUT mode and the Main Switch and "Desired Output %" adjustment are
The Aqua Rite electrolytic cell and flow detection switch will be damaged by freezing active.
water just as your pool plumbing would. In areas of the country which experience
severe or extended periods of freezing temperatures, be sure to drain all water from the NO FLOW When illuminated, the flow switch has detected no water flowing and
pump, filter, and supply and return lines before any freezing conditions occur. The the Aqua Rite has stopped generating chlorine. A flashing LED indicates a 15-60
electronic control is capable of withstanding any winter weather and should not be second time delay period.
removed.
CHECK SALT When flashing, the salt level is low (below 2700 ppm) and Aqua Rite
is generating at low efficiency. When illuminated steady, the salt level is too low and
Spring Start-up Aqua Rite has shut down. Before adding large quantities of salt, it is advisable to
DO NOT turn the Aqua Rite on, until the pool water chemistry has been brought to the have your salt level professionally checked.
proper levels. This information can be found on page 1.
HIGH SALT When illuminated, the salt level is too high and Aqua Rite has shut
down.

INSPECT CELL A flashing indicator signifies that either the cell efficiency is re-
duced or that it is time for regularly scheduled cell inspection. In either case, inspect
cell and clean if necessary. When illuminated steady, cell efficiency is greatly re-
duced and the Aqua Rite has stopped producing chlorine. Inspect, clean or replace
if necessary.

9 6
POUNDS and (Kg) OF STABILIZER (CYANURIC ACID) NEEDED FOR 80 PPM
Gallons and (Liters) of Pool/Spa water
Current
Stabilizer 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000
Level (ppm) (30000) (37500) (45000) (52500) (60000) (67500) (75000) (82500) (90000) (97500) (105000) (112500)(120000) (127500)(135000) (142500) (150000)
5.3 6.7 8.0 9.4 10.7 12.0 13.4 14.7 16.0 18.7 20.0 21.3 22.7 25.3 26.7
0 ppm (3.6) (4.3) (3.6) (4.3) (4.9) (5.4) (6.1) (6.7) (7.3) (8.5) (9.1) (9.7) (10.3) (11.5) (12.0)
4.7 5.8 7.0 8.2 9.4 10.5 11.7 12.9 14.0 15.2 16.4 17.2 18.7 19.8 21.0 22.2 23.3
10 ppm (3.2) (3.7) (3.2) (3.7) (4.3) (4.8) (5.3) (5.9) (6.4) (6.9) (7.4) (8.0) (8.5) (9.0) (9.5) (10.0) (10.5)

20 ppm 4.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 18.0 19.0 20.0
(2.7) (2.7) (3.2) (3.6) (2.2) (4.5) (5.0) (5.4) (5.9) (6.4) (6.8) (7.2) (8.1) (8.6) (9.0)
3.3 4.2 5.0 5.9 6.7 7.5 8.4 9.2 10.0 10.8 11.7 12.5 13.3 14.2 15.0 15.8 16.7

5
30 ppm (4.5) (4.9) (5.2) (5.6) (6.0) (6.3) (6.7) (7.1) (7.5)
(2.3) (2.7) (2.3) (2.7) (3.0) (3.4) (3.8) (4.2)
40 ppm 2.7 3.3 4.0 4.7 5.4 6.0 6.7 7.4 8.0 8.7 9.3 10.0 10.7 12.0 12.7 13.3
(1.8) (2.1) (1.8) (2.1) (2.4) (2.7) (3.0) (3.3) (3.6) (3.9) (4.2) (4.5) (4.8) (5.4) (5.7) (6.0)
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0
50 ppm (1.4) (1.6) (1.4) (1.6) (1.8) (2.0) (2.3) (2.5) (2.7) (2.9) (3.2) (3.4) (3.6) (3.9) (4.1) (4.3) (4.5)
1.3 1.7 2.0 2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0 5.3 5.7 6.3 6.7
60 ppm (.91) (1.1) (.91) (1.1) (1.2) (1.5) (1.7) (1.8) (2.0) (2.1) (2.3) (2.4) (2.6) (2.8) (3.0)
(1.4)
70 ppm 0.7 0.8 1.0 1.2 1.4 1.5 1.7 1.8 2.0 2.2 2.3 2.5 2.7 2.8 3.0 3.2 3.3
(.45) (.54) (.45) (.54) (.64) (.68) (.77) (.82) (.91) (1.0) (1.1) (1.2) (1.2) (1.3) (1.3) (1.4) (1.5)
80 ppm 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
POWER
120/240 VAC

to the Aqua Rite system.


POOL
FROM
SPA
FROM

Preparing Pool/Spa Water

Rite inside a panel or tight enclosed area.

10
more, if local codes require) from the pool/spa.
Mounting the Aqua Rite Control
INSTALLATION

G
AQUA

RITE

LDLINE
CONTROLS INC.

TO
Aqua Rite

POOL
Installation must be performed in accordance with Local and NEC codes.

TO
SPA

the box), it is important not to block the four sides of the control. Do not mount Aqua
anced BEFORE activating the Aqua Rite®. NOTE: If the pool does not have new water,

The control is designed to mount vertically on a flat surface with the knockouts facing
Refer to page 1 for recommended chemical levels. The pool's chemistry must be bal-

The Aqua Rite is contained in a raintight enclosure that is suitable for outdoor mount-
to the pool, per manufacturer's instructions. This ensures a quick, troublefree transfer

downward. Because the enclosure also acts as a heat sink (disperses heat from inside
add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of non-copper based algaecide

ing. The control must be mounted a minimum of 5 ft. (2 meters) horizontal distance (or
plumbing.

Flow Switch:
Plumbing

12”
min

3
1

operating the spa only.

11
local potable water supply. Consult local plumbing codes.

12”
min
2

4
chased separately. Refer to page 1 for information about available chlorinator cells.

(located on top of gray hex) points in the direction of water flow.


overchlorination of the spa during "spa only" operation. Never use configuration #4.

before (upstream) the flow switch. If the switch is plumbed after the
IMPORTANT: There must be at least a 12" (25cm) straight pipe run

Electrolytic Cell: Install using the unions provided. Tighten unions BY HAND for a
ensure proper operation, verify that the arrow on the flow switch
#1 shows the flow switch can also be in front of the cell. Configurations #2 and #3 allow
etc.). The electrolytic cell and flow switch tee fitting are designed to be plumbed into 2"
The Aqua Rite is packaged with a flow switch and cell unions. The cell must be pur-

watertight seal. For pool/spa combination systems with spillover,


(51mm) PVC pipe. Adapters (not included) can be used for systems with 1½" (38 mm)

for chlorination of both the pool and spa during spa spillover operation, but prevent
preferred installation is after (downstream) all the pool equipment (filter, heater, solar,

pool and spa during spillover but preventing overchlorination when


For proper plumbing, refer to the overview diagram on page 9. Alternate configurations

cell, the cell can by counted as the 12" (25cm) of straight pipe. To

use configurations #2 or #3 above to allow chlorination of both the


The flow switch and cell should be plumbed in the return line to the pool/spa. The
Ensure that the Aqua Rite® installation does not constitute a cross connection with the

POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM


Current salt Gallons and (Liters) of Pool/Spa water
level 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000 24,000 26,000 28,000 30,000 32,000 34,000 36,000 38,000 40,000
ppm (30,000) (37,500) (45000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000) (97,500) (105,000) (112,500)(120,000) (127,500)(135,000)(142,500)(150,000)
213 267 320 373 427 480 587 640 693 747 800 854 907 960 1067
0 (97) (194)
(121) (145) (170) (218) (242) (267) (291) (315) (339) (364) (388) (412) (436) (460) (484)

200
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000
(91) (114) (136) (159) (182) (205) (227) (250) (273) (295) (318) (341) (363) (385) (408) (430) (453)
187 233 280 327 373 420 467 513 560 607 653 700 747 793 840 887 933
400 (85) (106) (127) (148) (170) (191) (212) (233) (255) (276) (297) (318) (339) (360) (382) (403) (424)
173 217 260 303 347 390 433 477 520 563 607 650 693 737 780 823 867
600 (79) (98) (118) (138) (158) (177) (197) (217) (236) (256) (276) (297) (317) (337) (358) (378) (398)
160 200 240 280 320 360 400 440 480 520 560 600 640 680 720 760 800
800 (73) (91) (109) (127) (145) (164) (182) (200) (218) (236) (255) (273) (291) (310) (328) (346) (364)
147 183 220 257 293 330 367 403 440 477 513 550 587 623 660 697 733
1000 (67) (83) (100) (117) (133) (150) (167) (183) (200) (217) (233) (250) (267) (283) (300) (317) (333)
133 167 200 233 267 300 333 367 400 433 467 500 533 567 600 633 667
1200 (61) (76) (91) (106) (121) (136) (152) (167) (182) (197) (212) (227) (243) (258) (274) (289) (304)
120 150 180 210 240 270 300 330 360 390 420 450 480 510 540 570 600
1400 (55) (68)
4 (82) (95) (109) (123) (136) (150) (164) (177) (191) (205) (218) (232) (246) (259) (263)
107 133 160 187 213 240 267 293 320 347 373 400 427 453 480 507 533
1600
(48) (61) (73) (85) (97) (109) (121) (133) (145) (158) (170) (182) (195) (207) (219) (231) (243)
93 117 140 163 187 210 233 257 280 303 327 350 373 397 420 443 467
1800 (42) (53) (64) (74) (85) (95) (106) (117) (127) (138) (148) (159) (169) (180) (190) (201) (211)
80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400
2000 (36) (45) (55) (64) (73) (82) (91) (100) (109) (118) (127) (136) (145) (154) (163) (172) (181)

2200 67 83 100 117 133 150 167 183 200 217 233 250 267 283 300 317 333
(30) (38) (45) (53) (61) (68) (76) (83) (91) (98) (106) (114) (121) (129) (137) (144) (152)
53 67 80 93 107 120 133 147 160 173 187 200 213 227 240 253 267
2400 (24) (30) (36) (42) (48) (55) (61) (67) (73) (79) (85) (91) (98) (104) (110) (117) (123)

2600 40 50 60 80 90 100 110 120 130 140 150 160 170 180 190 200
(18) (23) (27) (32) (36) (41) (45) (50) (55) (59) (64) (68) (73) (77) (81) (86) (90)
2800 27 33 40 47 53 60 67 73 80 87 93 100 107 113 120 127 133
(12) (15) (18) (21) (24) (27) (30) (33) (36) (39) (42) (45) (48) (51) (54) (57) (60)

3000 13 17 20 23 27 30 33 37 40 43 47 50 53 57 60 63 67
(6) (8) (9) (11) (12) (14) (15) (17) (18) (20) (21) (23) (24) (26) (27) (29) (30)
3200 Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal Ideal
3400 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK
3600+ Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute Dilute
Salt Level Wiring
Use the chart on page 4 to determine how much salt in pounds or (Kgs) need to be added Power must be shut off at the circuit breaker before performing any wiring. Be sure to
to reach the recommended levels. Use the equations below (measurements are in feet/ follow Local and NEC electrical codes. To provide safe operation, the Aqua Rite® must
gallons and meters/liters) if pool size is unknown. be properly grounded and bonded.

Input Power For stand alone operation:


Wire the Aqua Rite to the LOAD SIDE of the filter pump timer. It is very important that
Gallons Liters the Aqua Rite is powered only when the pump is running.
(pool size in feet) (pool size in meters)
Length x Width x Length x Width x Refer to the wiring label on the Aqua Rite as well as the diagram below to determine
Rectangular correct wiring connections. The Aqua Rite is shipped from the factory with the configu-
Average Depth x 7.5 Average Depth x 1000
ration jumpers in 240VAC position. If using 120VAC, move the jumpers as shown below.
Diameter x Diameter x Diameter x Diameter x For Canadian models, the Aqua Rite shall be connected to a circuit protected by a class
Round
Average Depth x 5.9 Average Depth x 785 A ground fault interrupter. Be sure to connect the ground wire to the green ground
Length x Width x Length x Width x screw terminal located on the bottom of the enclosure.
Oval Average Depth x 6.7 Average Depth x 893
TYPICAL 240 VAC WIRING 120 VAC
TIMECLOCK AQUA AQUA
The ideal salt level is between 2700-3400 ppm (parts per million) with 3200 ppm being RITE RITE
optimal. If the level is low, determine the number of gallons in the pool and add salt SUBPANEL
according to the chart on page 4. A low salt level will reduce the efficiency of the Aqua GND GND

Rite® and result in low chlorine production. A high salt level can cause the Aqua Rite® LINE LOAD
to shutdown and may begin to give a salty taste to your pool (generally, the salt will
begin to be tasted at a level of about 3500-4000 ppm). The salt in your pool/spa is PCB PCB
constantly recycled and the loss of salt throughout the swimming season should be GROUND
small. This loss is due primarily to the addition of water because of splashing, BONDING
LUG
backwashing, or draining (because of rain). Salt is not lost due to evaporation.
IMPORTANT:
Type of Salt to Use PUMP
BONDING
MOVE JUMPERS
TO POSITIONS SHOWN
It is important to use only sodium chloride (NaCl) salt that is greater than 99% pure. This LOOP

is common food quality or water softener salt and is usually available in 40-80 lb. bags Note: Wire the pump directly to the timeclock--do not use the Aqua Rite as a junction box.
labeled "Coarse Solar Salt". It is also acceptable to use water conditioning salt pellets,
however, it will take longer for them to dissolve. Do not use rock salt, salt with yellow Bonding:
prussiate of soda, salt with anti-caking additives, or iodized salt. A lug used for bonding is attached to the bottom of the Aqua Rite enclosure (see
diagram below). The Aqua Rite must be bonded with an 8 AWG copper wire (6 AWG
How to Add or Remove Salt Canada) to the pool bonding system.
For new plaster pools, wait 10-14 days before adding salt to allow the plaster to cure.
Turn the circulating pump on and add salt directly into the pool. Brush the salt around Electrolytic Cell and Flow Switch:
to speed up the dissolving process--do not allow salt to pile up on the bottom of the The electrolytic cell and flow switch cables are terminated with connectors which plug
pool. Run the filter pump for 24 hours with the suction coming from the main drain (use into the Aqua Rite, for easy attachment and removal. The door of the Aqua Rite must be
pool vac if there is no main drain) to allow the salt to evenly disperse throughout the open to access the cell cable connector. The flow switch plugs into a connector (similar
pool. The salt display may take 24 hours to respond to the change in salt concentration. to a telephone jack) located outside, on the bottom of the enclosure. Refer to the
diagram below for the location of these connections.
The only way to lower the salt concentration is to partially drain the pool and refill with Flow switch connector
Cutout for
cell cable
fresh water.

Always check stabilizer (cyanuric acid), when checking salt. These levels will most
likely decline together. Use the chart on page 5 to determine how much stabilizer must
be added to raise the level to 80 ppm.

Bonding lug to
pool bonding system

3 12
Input power for use with Hayward/Goldline, Pentair and Water Chemistry
Polaris controls The table below summarizes the levels that are recommended by The Association of
Wire the Aqua Rite® DIRECTLY to 120/240VAC power (not through timer or relay). Pool and Spa Professionals (APSP). The only special requirements for the Aqua Rite
are the salt level and stabilizer. It is important to maintain these levels in order to
HAYWARD/GOLDLINE,
PENTAIR prevent corrosion or scaling and to ensure maximum enjoyment of the pool. Test your
or water periodically. Your Authorized Aqua Rite Dealer (AARD) or most pool stores can
POLARIS
AQUA RITE AQUA RITE
provide you with the chemicals and procedures to adjust the water chemistry. Be sure
(240 VAC) (120 VAC) to tell the pool store that you are using an Aqua Rite chlorine generator.

SUBPANEL
GND GND

PCB PCB

NEUTRAL
BONDING BONDING
GROUND LOOP LOOP

Optional Hayward/Goldline, Pentair and Polaris controls:


The Hayward/Goldline, Pentair and Polaris controls use a 4 wire connection to commu-
nicate to the Aqua Rite and can be wired up to 500' apart. Any outdoor rated 4 conductor
cable can be used. Refer to each manufacturer's instructions and the wiring diagrams
below for proper wiring connection to the Aqua Rite. NOTE: There must be only 1
"primary" unit. All other Aqua Rite units must be configured as "secondary".
Saturation index
4 GREEN The saturation index (Si) relates to the calcium and alkalinity in the water and is an
3
2
YELLOW
BLACK Jumper Installed
Jumper Removed
indicator of the pool water "balance". Your water is properly balanced if the Si is 0 ±.2.
1 RED For Primary
(Factory Default)
For Secondary(s) If the Si is below -0.2, the water is corrosive and plaster pool walls will be dissolved into
the water. If the Si is above +0.2, scaling and staining will occur. Use the chart below to
determine the saturation index.
Additional
Aqua Rite(s)
(if required)
Si = pH + Ti + Ci + Ai - 12.1
Hayward/Goldline, Aqua Rite Aqua Rite
(Secondary) Calcuim Total
Pentair (Primary) ºC ºF Ti Ci Ai
Hardness Alkalinity
or Polaris
Power Center 12 53 .3 75 1.5 75 1.9
100 1.6 100 2.0
16 60 .4
125 1.7 125 2.1
Hayward/Goldline - Attach wires to proper screw terminals as shown below. 19 66 .5 150 1.8 150 2.2
200 1.9 200 2.3
green
GRN 24 76 .6
GRN 4 4 250 2.0 250 2.4
YEL 3
yellow
3 YEL Pro Logic 29 84 .7 300 2.1 300 2.5
Aqua Rite BLK 2
black
2 BLK Aqua Logic 400 2.2 400 2.6
1
red
RED 34 94 .8
RED 1 600 2.4 600 2.8
39 103 .9 800 2.5 800 2.9

Pentair - Attach wires to opposite numbered screw terminals as shown below. Note How to use: Measure pool pH, temperature, calcium hardness,
and total alkalinity. Use the chart above to determine Ti, Ci,and
that the colors marked on the Pentair PCB do not match the Aqua Rite. Ai from your measurements. Insert values of pH, Ti, Ci and Ai
into the above equation. If Si equals .2 or more, scaling and
staining may occur. If Si equals -.2 or less corrosion or irritation
marking on PCB
(Colors Do Not Match) green may occur.
GRN 4 1 BLK / GND -.2 0 .2
yellow CORROSIVE SCALING
Aqua Rite YEL 3
black
2 GRN / -DT Intellitouch
BLK 2 3 YEL / +DT
red
RED 1 4 RED / +15 OK

13 2
OPERATION Polaris - Attach wires to proper screw terminals as shown below. Note that screw
terminal "1" is marked on the Polaris PCB.
The Aqua Rite is an automatic chlorine generation system for pool or spa sanitation.
®

The operation requires a low concentration of salt (sodium chloride) in the pool water. note
marked
These levels are low enough that it normally will not be tasted. The Aqua Rite automati- GRN 4
black
1 on PCB

cally sanitizes your pool by converting the salt into free chlorine which kills bacteria and YEL 3
yellow

algae in the pool. Chlorine will revert back to sodium chloride after killing bacteria.
Aqua Rite BLK 2
green Eos
These reactions will continuously recycle virtually eliminating the need to add sanitiz- RED 1
red

ing chemicals to your pool. The only time you may need to add more salt to the pool is
when water is replenished due to backwashing, draining, or splashing (not evapora-
tion).

The Aqua Rite is designed to handle the purification needs of most residential swim- TROUBLESHOOTING
ming pools up to 40,000 gallons (150,000 liters), or the needs of most commercial pools Visit www.goldlinecontrols.com for helpful information on operation, maintenance and
up to 25,000 gallons (95,000 liters). Check local codes for other restrictions. The actual troubleshooting your Aqua Rite® Electronic Chlorine Generator.
amount of chlorination required to properly sanitize a pool varies due to bather load,
rainfall, temperature, and the pool's cleanliness. Diagnostic Displays
Sequential pushes of the small "diagnostic" button next to the LCD display will cause
NOTE: Hayward does not recommend using the Aqua Rite to generate bromine. the Aqua Rite to display the following information:
Aqua Rite chlorine generators operating with software version 1.50 or later are designed 1. Pool temperature (xx degrees Fahrenheit or Celsius)
to use one of 3 different chlorinator cells that are available from your authorized Hay- 2. Cell voltage (xx.x volts)
ward dealer. These cells are not included with the Aqua Rite and must be purchased 3. Cell current (x.xx amps)
before installation. Choose the appropriate cell based on the size of your pool. The 4. Desired Output % ("0P" -- "100P" depending on knob position or input from remote
models are shown below: pool automation controller)
5. Instant salinity ( -xxxx ppm or -x.xx grams/Liter)
T-CELL-15- for pools up to 40,000 gallons 6. Product name sent to the pool automation control display ("AL-0" which signifies
T-CELL-9 - for pools up to 25,000 gallons "Aqua Rite")
T-CELL-3 - for pools up to 15,000 gallons 7. Software revision level (r1.xx)
8. Chlorinator cell type (t-3, t-5, t-9, t-15)
Note that the installation and mounting requirements are the same for all models.
On the 9th push of the button the display will revert back to the default salt display.
NOTE: Before installing this product as part of a saline water purification system in a Also, if the button is not pushed for 30 seconds, the display will revert back to the
pool or spa using natural stone for coping or for immediately adjacent patios/decking, a standard salt display.
qualified stone installation specialist should be consulted regarding the appropriate
type, installation, sealant (if any) and maintenance of stone used around a saline pool Common Problems and Solutions
with electronic chlorine generator in your particular location and circumstances. 1. "Power" LED not on
Check to make sure either 120VAC or 240VAC input power is connected to the proper
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged espe- screw terminals at the Aqua Rite control. Verify input voltage with a voltmeter. If there
cially in arid regions where pool water is subject to excessive evaporation and is not is input power, the fuse may have blown. The Aqua Rite is protected by a 20 amp mini
commonly diluted with fresh water. Dry acid can cause a buildup of by-products that ATO fuse located on the circuit board above the cell connector.
can damage your chlorinator cell.
2. "Generating" LED flashing
The temperature of the pool water is too high or low to operate. You can override this by
switching the main switch to SUPER CHLORINATE. The Aqua Rite will run at maximum
output for the remainder of the current pump cycle or 24 hours, whichever comes first.

3. "No Flow" LED illuminated


The Aqua Rite has sensed a no flow condition and has stopped generating chlorine.
Check that the flow switch is plugged into the connector on the bottom of the control
unit and that the wire is not cut or damaged. Make sure you have at least 12" of straight
pipe before the flow switch. If there is adequate flow and the LED is still on, check that
the arrows on the flow switch (on top of hex) are pointing in the direction of flow.

1 14
4. "Check Salt" LED illuminated or flashing
Be sure that the correct model Turbo Cell has been selected (page 7).
Check salt level in pool/spa. If salt level is low, add salt according to chart on page 4.
Before adding large quantities of salt, it is advisable to have your salt level profession-
ally checked.

5. "High Salt" LED illuminated


Be sure that the correct model Turbo Cell has been selected (page 7). Table of Contents
Check salt level in pool/spa. If salt level is too high, lower salt level by draining some of
the pool water out of the pool and replace with fresh water. Continue until the salt
concentration is at recommended levels.

6. "Inspect Cell" LED flashing OPERATION


Be sure that the correct model Turbo Cell has been selected (page 7). General.........................................................................................1
Inspect and clean cell according to directions on page 8. When done, press the "diag-
nostic" button for 3 seconds to stop the "Inspect Cell" LED flashing. Water Chemistry........................................................................2
7. "Inspect Cell" LED illuminated
Be sure that the correct model Turbo Cell has been selected (page 7). Controls........................................................................................6
Remove and inspect the cell for scale. If the cell is scaled, follow the directions on page
8 for cell cleaning. If the pool has the proper amount of salt and the "Inspect Cell" LED Maintenance.................................................................................8
is still illuminated, the cell may be worn and need replacement.
8. Possible causes of little or no free chlorine residual
- Aqua Rite® switch in OFF position. INSTALLATION
- Desired Output % adjustment setting is too low. Mounting........................................................................................10
- Low stabilizer (Cyanuric Acid).
- Filter pump time too short (8 hours for average size pools, more for large pools)
- Salt level too low (below 2400 ppm, Check Salt LED on). Plumbing.......................................................................................11
- Salt level too high (High Salt LED on).
- Very warm pools increase chlorine demand--increase Output %, or filter run time. Wiring............................................................................................12
- Cold water (below 50ºF) causes Aqua Rite to stop generating (Generating LED flash-
ing).
- Excessive scaling on cell.
- High level of Nitrogen in pool water. TROUBLESHOOTING
- "Yellow Out" or similar treatment recently used. Some yellow algae treatments will Troubleshooting.........................................................................14
use chlorine at a very high rate and deplete the residual free chlorine. Manually shock
the pool if indicated in the directions on the algae treatment. It still may be a matter of
days before the pool returns to "normal" and chlorine tests will show the desired 1-
3ppm free chlorine reading.
WARRANTY
9. "-Pcb-" displayed and all 4 red/yellow LEDs are illuminated. Warranty......................................................................................16
A possible Printed Circuit Board fault has been detected. Call for
service.

15
LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and
IMPORTANT SAFETY INSTRUCTIONS E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and
SwimPure chlorination products to be free of defects in materials and workmanship, under
When using this electrical equipment, basic safety precautions normal use and service, for a period of three (3) years. Hayward/Goldline also warrants its
Aqua Trol chlorination products to be free of defects in materials and workmanship, under
should always be followed, including the following: normal use and service for a period of one (1) year. These warranties are applicable from the
initial date of installation on private residential swimming pools in the US and Canada.

• READ AND FOLLOW ALL Hayward/Goldline warrants all the above-identified pool automation and chlorination prod-
ucts installed on commercial swimming pools and on swimming pools outside of the US and
INSTRUCTIONS Canada for a period of one (1) year. Likewise, Hayward/Goldline warrants all accessories
and replacement parts for the above-identified pool automation and chlorination products for
a period of one (1) year. Each of these warranties is not transferable and applies only to the
original owner.
• Use Copper Conductors Only
Proof of purchase is required for warranty service. If written proof of purchase is not
provided, the manufacturing date code will be the sole determinant of the date of installation
• Disconnect all AC power during installation. of the product. To obtain warranty service or repair, please contact the place of purchase or
the nearest Hayward/Goldline authorized warranty service center. For more information on
authorized service centers please contact the Hayward/Goldline Technical Service Support
• Warning - To reduce the risk of injury, do not permit Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the Goldline web site at
children to use this product unless they are closely www.goldlinecontrols.com or the Hayward website at www.haywardnet.com.
supervised at all times. WARRANTY EXCLUSIONS:
1. Material supplied or workmanship performed by others in process of installation.
• A green colored terminal marked "Earth Ground" is lo- 2. Damage resulting from improper installation including installation on pools larger than the
cated inside the wiring compartment. To reduce the risk product rating.
of electric shock, this terminal must be connected to the 3. Problems resulting from failure to install, operate or maintain the product(s) in accordance
with the recommendations contained in the owners manual(s).
grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to 4. Problems resulting from failure to maintain pool water chemistry in accordance with the
recommendations in the owners manual(s).
the circuit conductors supplying the equipment.
5. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or
alternations, fire, flood, lightning, freezing, external water, degradation of natural stone used in
• One bonding lug for US models (two for Canadian mod- or immediately adjacent to a pool or spa, war or acts of God.
els) is provided on the external surface. To reduce the
DISCLAIMER. THE EXPRESS LIMITED WARRANTIES ABOVE CONSTITUTE THE
risk of electric shock, connect the local common bonding ENTIRE WARRANTIES WITH RESPECT TO THE ABOVE-IDENTIFIED HAYWARD/
grid in the area of the swimming pool, spa, or hot tub to GOLDLINE POOL AUTOMATION AND CHLORINATION PRODUCTS AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WAR-
these terminals with an insulated or bare copper conduc- RANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
tor not smaller than 8 AWG US / 6 AWG Canada. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO
HAVE OTHER RIGHTS OF EQUIPMENT, LOST PROFITS OR REVENUE, COSTS
OF RENTING REPLACEMENTS, AND OTHER ADDITIONAL EXPENSES, EVEN IF
• All field installed metal components such as rails, ladders, THE SELLER HAD BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME STATES DO NOT ALLOW THE EXCLUSION OF LIMITATION OF INCI-
drains, or other similar hardware within 3 meters of the DENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR
pool, spa or hot tub shall be bonded to the equipment EXCLUSION MAY NOT APPLY TO YOU.
grounding bus with copper conductors not smaller than 8 NO WHOLESALER, AGENT, DEALER, CONTRACTOR OR OTHER PERSON IS
AWG US / 6 AWG Canada. AUTHORIZED TO PROVIDE, SUPPLEMENT OR MODIFY ANY WARRANTY ON
BEHALF OF HAYWARD/GOLDLINE.
THESE WARRANTIES ARE VOID IF THE PRODUCT HAS BEEN ALTERED IN ANY
• NOTICE TO USERS: This control product is to be used WAY AFTER LEAVING THE FACTORY. FOR THE ABOVE-IDENTIFIED CHLORI-
only in accordance with the directions of this label. It is NATION PRODUCTS, THESE WARRANTIES ALSO ARE VOID IF, DURING THE
WARRANTY PERIOD, YOU USE A REPLACEMENT CHLORINATOR CELL OTHER
an offense under the Pest Control Products Act to use a THAN AN UNMODIFIED, NEW HAYWARD/GOLDLINE CHLORINATOR CELL PUR-
control product under unsafe conditions. CHASED FROM HAYWARD/GOLDLINE. IF A WARRANTY BECOMES VOID, YOU
STILL MAY PURCHASE SERVICE AND/OR TELEPHONE TECHNICAL SUPPORT
AT THE THEN CURRENT TIME AND MATERIAL RATES.
• SAVE THESE INSTRUCTIONS 16
ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
TEST IDEAL RANGE ADJUSTMENT REQUIRED

Raise desired output % to


Free Chlorine 1.0 - 3.0 ppm increase, lower desired output %
WEEKLY

Aqua Rite
to decrease -OR- increase or
decrease pump filtration time. ®
pH 7.2 - 7.8
Too high - add muriatic acid
Too low - add soda ash.

Alkalinity 80 - 120 ppm Add baking soda to increase.


MONTHLY

Add acid as required to decrease.

Salt 2700 - 3400 ppm Add salt as required to increase.

Stabilizer 60 - 80 ppm Add cyanuric acid to increase.


QUARTERLY

Calcium 200 - 400 ppm Add calcium to increase.


Drain and add water to decrease.

Electrolytic Cell inspect & clean Refer to section in manual.

Head Loss Curve


14
13 Electronic Chlorine Generator
12 12.03
Head Loss (FtH O)

11
2

10
9
8
7
6.79
Operation and Installation
6
5 Manual
4
AQR
3 3.08
2
1
.82
0
40 (25%) 80 (50%) 120 (75%) 160 (100%)

Flow Rate (gpm)

620 Division St. 092009N RevP