The WSM06020W-61 is a solenoid-operated, direct-acting, normally closed cartridge valve capable of handling pressures up to 350 bar and flow rates of 25 l/min. It features high performance for long service life, excellent switching performance, and advanced corrosion protection. The valve is designed for various applications with specific technical characteristics and installation requirements detailed in the document.

Uploaded by

vendas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views4 pages

WSM06020W 61 2 - 2 Directional Poppet Valve 59493 en V4

The WSM06020W-61 is a solenoid-operated, direct-acting, normally closed cartridge valve capable of handling pressures up to 350 bar and flow rates of 25 l/min. It features high performance for long service life, excellent switching performance, and advanced corrosion protection. The valve is designed for various applications with specific technical characteristics and installation requirements detailed in the document.

Uploaded by

vendas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

2

2/2 directional poppet valve


WSM06020W-61

1 Solenoid operated, direct-acting,


up to 25 l/min normally closed,
up to 350 bar
cartridge valve metric – 350 bar
FUNCTION PRODUCT ADVANTAGE
z High performance version for high pressures and long service life
z Coil seals protect the solenoid system
z Wide variety of connectors available
z Excellent switching performance by high-performance HYDAC solenoid
z External surfaces with advanced corrosion protection thanks to
ZnNi coating (1,000 h salt spray test)

DESCRIPTION OF FUNCTION
WSM06020W-61 is the high-performance version of the standard WSM06020W-01. With
its larger coil and modified design, it can switch at pressures of up to 350 bar and allows
a flow rate of 25 l/min. When the solenoid coil is de-energised, the valve blocks flow in
both directions. When the solenoid coil is energised, there is free flow through the valve
in both directions.

Important note:
No metering orifice is permitted just upstream from port 1.

1
EN 5.949.3.4/06.24

1
TECHNICAL CHARACTERISTICS1)
Operating pressure max. 350 bar
Flow rate max. 25 l/min
Internal leakage Leak-free, max. 5 drops/min (0.25 cm³/min) at nominal pressure, ν = 34 mm2/s
Pressure fluid Hydraulic oil to DIN 51524 Part 1, 2 and 3
Ambient temperature range min. -40 °C to max. +60 °C
Temperature range of pressurised NBR: min. -20 °C to max. +100 °C
operating fluid FKM: min. -20 °C to max. +120 °C
Viscosity range min. 10 mm²/s to max. 420 mm²/s
Filtration Permitted operating fluid contamination level according to
ISO 4406 Class 21/19/16 or higher
MTTFD 150 - 1200 years, assessment according to DIN EN ISO 13849-1:2016;
Table C.1, Confirmation of ISO 13849-2:2013; Tables C.1 and C.2
Installation position User-definable
Material Valve body: Steel, hardened
Spools: Steel, hardened and ground
Seals: NBR (standard)
FKM (optional)
Support rings: PTFE
Coil: Steel/polyamide
Cavity 06020
Weight 0.42 kg (with coil)
Electric system
Type of voltage DC: DC voltage
AC: AC with rectifier integrated in the coil
Nominal current at 20 °C 2.22 A at 12 V DC
1.13 A at 24 V DC
Voltage tolerance ±15 % of nominal voltage
Duty cycle 100 % duty cycle (continuous operation) up to max. 115 % of the nominal voltage at 60 °C ambient temperature
Response time Energised: approx. 30 ms
at pmax; Qmax, ν = 34 mm2/s De-energised: approx. 40 ms
Greatly increased reaction times possible for other operating conditions
Coil design Coil …-50-1836
1)
see "Conditions and Instructions for Valves" in brochure 53.000.

DIMENSIONS
23.8

Ø36.3

Manual override

Tightening torque
4 Nm

After loosening the


mounting nut, the coil can
be rotated through 360° and
removed
86 max.

84 max.
50.3

6kt SW24
12.5

Tightening torque*
2.5
26

2
EN 5.949.3.4/06.24

1
* Tightening torque: Ø15
Steel housing (burst strength > 360 N/mm²): 40 Nm M20x1.5
Aluminium housing (burst strength > 330 N/mm²): 35 Nm Millimetre
(With torque tool according to DIN EN ISO 6789, tool type II class A or B). Subject to technical modifications.

2
CAVITY
06020
25

0.02 M20x1.5 X 4:1


0.05 A B

1 ±0.2
PD Rz2 6.3
A
Rz1 10 ACS
0.1 B

9.8 min.*
VE
12.5 ±1

30° ±1° (Including angle)


14.6 ±0.1

X Rz 6.3

16 max.*
26.5 ±0.5 Fitting depth

60° ** ACS
0.05 A B 21.4 ±0.05
28.5 ±0.5

25.7

2 R0.2 ±0.2
R0.15 ±0.05
Rz 6.3

45°

3.2 ±0.2
Ex.: 7
1
Max. Nominal : 14 VE = Visual Examination
B
H8
15 Ra 6.3 Rz 6.3 Rz 10
0.05 A B
[ 14±1]

* Permitted boring zone (for block design) Millimetre


** Sharp edges should be avoided by using a radius of 0.1 mm to 0.2 mm Subject to technical modifications.

MODEL CODE
WSM06020W – 61M – C – N – 24 DG
Designation
2/2 directional poppet valve
Design
619 = Standard
61M9 = with manual override
Type of connection
C = Cartridge valve
Sealing material
N = NBR (standard)
V = FKM
Nominal voltage
12 = 12 V DC
24 = 24 V DC
115 = 115 V AC
230 = 230 V AC
Further versions on request.

Coil design (50-1836) Number of poles Port Protection class


DC
DG = design A acc. to DIN EN 175301-803 3-pin radial IP65
DK = Kostal threaded terminal M27x1 2-pin radial IP65 / IP67
DL = 2 free wires 0.75 mm² x 457 mm (18'') 2-pin radial IP65 / IP67
DN = Deutsch DT04-2P plug 2-pin axial IP65 / IP67
DO = M12 plug 4-pin radial IP65
DT = AMP Junior Timer 2-pin radial IP65 / IP67
DU = AMP Junior Timer 2-pin axial IP65 / IP67
AC
AG = design A acc. to DIN EN 175301-803 3-pin radial IP65
Further versions on request.
EN 5.949.3.4/06.24

3
TYPICAL PERFORMANCE CURVES
Δp/Q performance curve 1→2 measured at ν = 34 mm2/s, TOil = 46 °C
[psi] [bar]
30

400

25
350

300
20 2→1, 100 % Imax
Pressure drop Δp

250 1→2, 100 % Imax


15
200

150 10

100
5
50

0 0
0 5 10 15 20 25 30 [l/min]
0 1 2 3 4 5 6 7 [gpm]
Flow rate Q

MATERIAL OVERVIEW
Standard models
Designation Part no.
WSM06020W-61-C-N-12DG 3707060
WSM06020W-61-C-N-24DG 3531890
WSM06020W-61M-C-N-24DG 3592515
WSM06020W-61-C-V-24DG 3666937
WSM06020W-61-C-N-230AG 3531891
Further versions on request.

Spare parts, seal kits


Designation Material Code Part no.
Seal kit NBR 06020-NBR 3119017
Seal kit FKM 06020-FKM 3262477

Housing
Designation Material Code Pressure max. Connections Weight Part no.
Inline connection housing Steel, zinc-plated R06020-01X-01 350 bar G3/8" 0.42 kg 275266

Cavity tools
Designation Part no.
Countersink (shank MK3) 170033
Reamer (shank MK2) 1000768

HYDAC FLUIDTECHNIK GMBH


NOTE
Justus-von-Liebig-Str.
EN 5.949.3.4/06.24

The information in this brochure relates to the operating conditions and fields of application 66280 Sulzbach/Saar
described. For applications and operating conditions not described: please contact the Germany
relevant technical departments. Phone: +49 6897 509-01
Subject to technical modifications. Email: [email protected]
Documents are only valid if they have been obtained via the website and are up-to-date. Internet: www.hydac.com
4

You might also like