ES-50X FIRELITE System

The ES-50X Series consists of intelligent addressable fire alarm control panels that replace the MS-9050UD, supporting up to 50 addressable devices. Key features include dual-technology communicators for both POTS and IP, remote programming capabilities, and various optional modules for enhanced functionality. The panels are designed for ease of installation and maintenance, offering advanced monitoring and alarm verification options.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views4 pages

ES-50X FIRELITE System

The ES-50X Series consists of intelligent addressable fire alarm control panels that replace the MS-9050UD, supporting up to 50 addressable devices. Key features include dual-technology communicators for both POTS and IP, remote programming capabilities, and various optional modules for enhanced functionality. The panels are designed for ease of installation and maintenance, offering advanced monitoring and alarm verification options.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

DF-60953:D

ES-50X Series
Intelligent Addressable
Fire Alarm Control Panels
Addressable Fire Alarm Control Panels

General
The ES-50X, ES-50XC, ES-50XI, and ES-50XP are the latest intelli-
gent addressable fire alarm control panel (FACPs) from Fire•Lite
Alarms and are direct replacement for the MS-9050UD. The ES-50X
Series support up to 50 addressable devices in any combination of
detectors or modules. With an extensive list of powerful features, the
ES-50X Series programs just like Fire•Lite’s other addressable panels,
yet fits into applications previously served only by conventional panels.
The ES-50X and ES-50XC feature a pre-installed IPOTS-COM, a dual
technology (POTS and IP) communicator. The POTS transmits system
status (alarms, troubles, AC loss, etc.) to a Central Station via the pub-
lic switched telephone network. The IP communicator’s internet moni-
toring capability sends alarm signals over the Internet saving the
monthly cost of two dedicated business telephone lines. Although not
required, the secondary telephone line may be retained providing
backup communication over the public switched telephone line.
Optional cellular reporting is available using an HW-TG7F Series
Communicators or the CLSS Pathway.
The ES-50XP features an integrated CLSS Pathway Pro Communica-
tor, a dual-SIM (AT&T/ Verizon) 5G LTE-M Communicator with optional
IP connection. The CLSS Pathway Pro transmits system status
(alarms, troubles, AC loss, etc.) to the Central Station using LTE CAT-
M1 networks, serving as a bridge between the fire system and the
• Four programmable function keys for ease of maintenance
CLSS Cloud. The IP communicator's Internet monitoring capability
sends alarm signals over the Internet, meeting requirements for • Two programmable relays and one fixed trouble relay
backup communication. As an integrated communicator, the CLSS • Built-in Programmer
Pathway Pro, typically, can transmit data faster than dial capture meth- • Integral 80-character LCD display with backlighting
ods. • Real-time clock/calendar with automatic daylight savings control
Remote and local programming of the control panel is possible using • History file with 1,000 event capacity
the FS-Tools Upload/Download utility. Programming databases can be • Addressable sounder base
uploaded/downloaded via the panel’s USB port (and USB cable) or via • Multi-criteria detector (smoke, heat, CO) with programmable
an ethernet connection using the IPOTS-COM communicator (ES-50X response
and EX-50XC only). The USB port also allows for the download or • Control module delay timer
upload of the entire program, history file, walk-test data, current status • Automatic detector sensitivity testing (NFPA 72 compliant)
and system voltages by means of a USB flash drive.
• Automatic device type-code verification
The power supply and all electronics are contained on a circuit board • Point trouble identification
supported on a new quick install chassis and housed in a metal cabi- • Waterflow selection per module point
net. Available accessories include local and remote upload/download
• Alarm verification selection per detector point
software, remote annunciators, and reverse polarity/city box transmit-
ter (4XTMF). • Maintenance alert warns when smoke detector dust accumulation
is excessive
• One-person audible or silent walktest with walktest log & printout
Features
• System alarm verification selection per detector point
• Listed to UL Standard 864, 10th edition • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72
• Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- compliant)
phone Service) Central Station Communicator (ES-50X and EX- • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus
50XC only) • Remote Acknowledge, Alarm Silence, Reset and Drill via address-
• Optional Cellular Central Station Communicators over AlarmNet® able modules or remote annunciator
(ES-50X and EX-50XC only) • Upload/Download of program and data via USB with optional
• Integrated CLSS Pathway Pro Communicator; dual SIM AT&T/Veri- FS-Tools Programming Utility
zon networks with LTE-CAT-M1 5G technology (EX-50XP only)
• Cloud monitoring using Honeywell’s Connected Life Safety Ser- SLC (DCL) COMMUNICATION LOOP
vices (CLSS) Cloud solutions software (EX-50XP only) • Supports LiteSpeed™ and CLIP protocols
• Compatible with SWIFT® wireless devices • SLC (DCL) operates up to 10,000 ft. (3,000 m) in LiteSpeed mode
• Auto-programming (learn mode) reduces installation time. Reports with twisted, unshielded wire
two devices set to the same address • Single addressable SLC (DCL) loop which meets NFPA Class B
• Two independently programmable, built-in, Class A or Class B NAC and Class A requirements
circuits • 50 addressable device capacity (any combination of addressable
• Selectable strobe synchronization for System Sensor, Wheelock, detectors and modules)
and Gentex devices • Compatible with Fire•Lite’s addressable devices (refer to the SLC
• Notification Appliance Circuit End of Line resistor matching Wiring Manual)

DF-60953:D • 3/27/2023 — Page 1 of 4


NOTIFICATION APPLIANCE CIRCUITS (NACS) HW-TG7FE-A/HW-TG7FE-V: CLSS-Enabled 5G/LTE-M Dual Path
• Two independently programmable output circuits. Circuits can be Commercial Fire Alarm Communicators for AT&T and Verizon
configured for Class A or Class B wiring. HW-TG7FP-A/HW-TG7FP-A: CLSS-Enabled 5G/LTE-M Sole Path
– Class B Commercial Fire Alarm Communicators for AT&T and Verizon
– Class A DP-ES-R: Optional dress panel.
• Silence Inhibit and Autosilence timer options TR-CE: Optional trim ring for semi-flush mounting.
• Continuous, March Time, Temporal, or California code for main cir- BB-2F: Optional cabinet for one or two modules.
cuit board NACs with two-stage capability BB-6F: Optional cabinet for up to six modules mounted on CHS-6
• Selectable strobe synchronization per NAC chassis.
• 2.5 A special application, 250mA regulated, total power for NACs BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75.
NOTE: Maximum or total 24VDC system power shared between all NAC BB-55F: Battery box, houses two 55 AH batteries
circuits and the ANN-BUS is 2.7 A CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet.
CHG-75: Battery charger for lead-acid batteries with a rating of 25 to
PROGRAMMING AND SOFTWARE
75 AH.
• Autoprogramming (learn mode) reduces installation time CHG-120F: Remote battery charging system for lead-acid batteries
• Custom English labels (per point) may be manually entered or with a rating of 55 to 120 AH. Requires additional BB-55F for mount-
selected from an internal library file ing.
• Two programmable Form-C relay outputs NOTE: CHG-120F or CHG-75 required for batteries larger than 18AH.
• 50 software zones BAT Series: Batteries, see data sheet DF-52397.
• Continuous fire protection during online programming PRN Series: UL listed compatible event printer.
• Program Check automatically catches common errors not linked to
any zone or input point OPTIONAL MODULES
• OFFLINE PROGRAMMING: Create the entire program in your 4XTMF Reverse Polarity Transmitter Module: Provides a super-
office using FS-Tools, a Windows®-based software package, and vised output for local energy municipal box transmitter, alarm and trou-
upload/download system programming locally. Offline programming ble. Includes a disable switch and disable trouble LED.0
requires an ethernet connection. FS-Tools is available on
www.firelite.com. COMPATIBLE ANNUNCIATORS
ANN-80: Remote, red LCD annunciator mimics the information dis-
User interface played on the FACP LCD display. Recommended wire type is un-
shielded.
LED INDICATORS
ANN-100: Remote LCD annunciator mimics the information displayed
• Fire Alarm (red) • CO Alarm (yellow)
on the FACP LCD display. Recommended wire type is un-shielded.
• AC Power (green) • Supervisory (yellow)
For use in FM applications only.
• Trouble (yellow) • Ground fault (yellow)
ANN-I/O: LED Driver Module provides connections to a user supplied
• Battery fault (yellow) • Disabled (yellow)
graphic annunciator. (See DF-52430.)
• Maintenance (yellow) • Communication (yellow)
• Alarm Silenced (yellow) • F1-F4 Programmable Function Keys ANN-LED: Annunciator Module provides three LEDs for each zone:
(yellow) Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DF-
60241.)
KEYPAD ANN-RLED: Provides alarm (red) indicators for up to 30 input zones
• 16 key alpha-numeric pad • Acknowledge or addressable points. (See DF-60241.)
• Alarm Silence • Drill (Manual Evacuate) ANN-RLY: Relay Module provides 10 programmable Form-C relays.
• Four (4) programmable function keys • Reset (lamp test) Can be mounted inside the cabinet. (See DF-52431.)
ANN-S/PG: Serial/Parallel Printer Gateway module provides a con-
Product Line Information nection for a serial or parallel printer. (See DF-52429.)
ES-50X: Addressable Fire Alarm Control Panel with one SLC loop. ADDRESSABLE DEVICES
Includes main circuit board with display, pre-installed IPOTS-COM All feature a polling LED and rotary switches for addressing.
communicator, chassis with transformer, backbox with door, plastic
bag containing screws, cables, key, etc. SD365(A): Addressable low-profile photoelectric smoke detector. Lite-
ES-50XC: Addressable Fire Alarm Control Panel with one DCL loop. Speed only.
Includes main circuit board with display, pre-installed IPOTS-COM SD365(A)-IV: Addressable low-profile photoelectric smoke detector.
communicator, chassis with transformer, dress panel, backbox with Ivory. LiteSpeed and CLIP mode.
door, plastic bag containing screws, cables, key, etc. SD365T(A): Addressable low-profile photoelectric smoke detector
ES-50XI: Addressable Fire Alarm Control Panel with one SLC loop. with thermal sensor. LiteSpeed only.
Includes main circuit board with display, chassis with transformer, SD365T(A)-IV: Addressable low-profile photoelectric smoke detector
dress panel, backbox with door, plastic bag containing screws, cables, with thermal sensor. Ivory. LiteSpeed and CLIP mode.
key, etc.
SD365R(A): Remote test capable addressable photoelectric smoke
ES-50XP: Addressable Fire Alarm Control Panel with one SLC loop. detector for use with DNR(W)(A) duct detector housing. LiteSpeed
Includes main circuit board with display, pre-installed CLSS Pathway only.
Pro communicator, chassis with transformer, dress panel, backbox
with door, plastic bag containing screws, cables, key, etc. SD365R(A)-IV: Remote test capable addressable photoelectric smoke
detector for use with DNR(W)(A) duct detector housing. Ivory. Lite-
FS-Tools: Programming software for Windows®-based PC computer.
Speed and CLIP mode.
Available for download at www.firelite.com.
SD365CO: Addressable, low-profile device that provides fire, heat,
IPOTS-COM: Dual technology (POTS and IP) communicator.
and carbon monoxide (CO) detection.
(replacement board) (ES-50X and EX-50XC only)
HW-AV-LTE-M: Optional CLSS Pathway SD365CO-IV: Addressable, low-profile device that provides fire, heat,
and carbon monoxide (CO) detection. Ivory. LiteSpeed and CLIP
HW-TG7FS-A/HW-TG7FS-V: CLSS-Enabled 5G /LTE-M Commercial
mode.
Fire Alarm Communicators for AT&T® and Verizon®
H365(A): Low-profile 135°F fixed thermal sensor. LiteSpeed only.

Page 2 of 4 — DF-60953:D • 3/27/2023


H365(A)-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed BG-12LX: Addressable manual pull station with interface module
and CLIP mode. mounted inside.
H365R(A): Low-profile, intelligent, rate-of-rise thermal sensor. Lite- I300(A): This module isolates the SLC (DCL) loop from short circuit
Speed only. conditions (required for Class A or Class X operation).
H365R(A)-IV: Low-profile, intelligent, rate-of-rise thermal sensor. ISO-6(A): Six-fault isolator module. Mount one or two modules in a
Ivory. LiteSpeed and CLIP mode. BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chas-
H365HT(A): Low-profile intelligent 190°F/88°C fixed thermal sensor. sis in a BB-6F cabinet.
LiteSpeed only. SMB500: Used to mount all modules except MMF-301 and M301.
H365HT(A)-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- MMF-300-10(A): Ten-input monitor module. Mount one or two mod-
sor. Ivory. LiteSpeed and CLIP mode. ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-
6 chassis in a BB-6F cabinet.
D365PL(A): Low-flow non-relay duct-detector housing; includes
SD365R(A). MMF-302-6(A): Six-zone interface module. Mount one or two modules
in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6
Legacy Devices
chassis in a BB-6F cabinet.
CP355(A)Addressable, intelligent smoke detector that incorporates an CMF-300-6(A): Six-circuit supervised control module. Mount one or
ionization sensing chamber. two modules in a BB-2F cabinet (optional). Mount up to six modules
SD355(A): Addressable low-profile photoelectric smoke detector. on a CHS-6 chassis in a BB-6F cabinet.
SD355T(A): Addressable low-profile photoelectric smoke detector CRF-300-6(A): Six-relay control module (Form-C relays). Mount one
with thermal sensor. or two modules in a BB-2F cabinet (optional). Mount up to six modules
SD355R(A): Remote test capable addressable photoelectric smoke on a CHS-6 chassis in a BB-6F cabinet.
detector for use with DNR(W)(A) duct detector housing. SWIFT Wireless Devices
SD355CO: Addressable, low-profile device that provides fire, heat, W-GATE(A): LiteSpeed Wireless Gateway
and carbon monoxide (CO) detection. W-SD355(A): LiteSpeed intelligent, wireless photo detector.
H355(A): Fast-response, low-profile heat detector. W-H355R(A): LiteSpeed intelligent wireless rate of rise (135°) heat
H355R(A): Fast-response, low-profile heat detector with rate-of-rise detector.
option. W-SD355T(A): intelligent wireless photo/heat detector.
H355HT(A): Fast-response, low-profile heat detector that activates at W-H355(A): LiteSpeed intelligent wireless fixed-temperature (135°)
190°F/88°C. heat detector.
AD355(A): Low-profile, intelligent, “Adapt” multi-sensor detector W-MMF(A): LiteSpeed Intelligent wireless monitor module.
(B350LP base included). W-CRF(A): LiteSpeed Intelligent wireless relay module.
B200S(A)(-WH)(-IV): Programmable, addressable sounder base. W-BG12LX(A): LiteSpeed Intelligent wireless pull station.
B200SR(A)(-WH)(-IV): Addressable sounder base. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV
B200S-LF(-WH)(-IV): Programmable, addressable sounder base, low- bases.
frequency. W-USB: Wireless USB radio/antenna dongle that plugs into the USB
B200SR-LF(-WH)(-IV): Addressable sounder base, low-frequency. port of a PC running SWIFT Tools.
BEAM355: Intelligent beam smoke detector. SWIFT Tools: Programming and diagnostic utility for the Wireless
Gateway and devices. Available for download from www.firelite.com.
BEAM355S: Intelligent beam smoke detector with integral sensitivity
NOTE: For more information on Compatible Addressable Devices for use
test.
with the ES-50X, see the following data sheets (document numbers):
D355PL(A): InnovairFlex low-flow non-relay duct-detector housing; SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-52386),
includes SD355R(A). BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374),
DNR(A): InnovairFlex™ low-flow non-relay duct-detector housing. CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series (DF-
(Order SD355R(A)/SD365R(A) separately.) 52385), I300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MDF-300
(DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/
DNRW: InnovairFlex low-flow non-relay duct-detector housing, with SD355T (DF-52384), and SLC Wiring Manual (51309).
NEMA-4 rating. Watertight. (Order SD355R(A)/SD365R(A) sepa-
rately.) NOTE: Legacy 300 Series detection devices such as the CP300/CP350,
SD300(T)/SD350(T) and older modules such as the M300, M301, M302,
Addressable Modules C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC
MMF-300(A): Addressable Monitor Module for one zone of normally- (DCL) contains one of these devices, polling must be set for standard CLIP
open dry-contact initiating devices. Mounts in standard 4.0" (10.16 protocol. Please consult factory for further information on previous 300
cm.) box. Includes plastic cover plate and end-of-line resistor. Module Series devices.
may be configured for either a Class B or Class A IDC. ADDRESSABLE DEVICE ACCESSORIES
MDF-300(A): Dual Monitor Module. Same as MMF-300(A) except it End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm
provides two Class B-only IDCs. assembly supervises the MMF-300(A), MDF-300(A), MMF-301(A),
MMF-301(A): Miniature version of MMF-300(A). Excludes LED and and CMF-300(A) module circuits. The 3.9k ohm assembly supervises
Class A option. Connects with wire pigtails. May mount in device back- the MMF-302(A) module circuit. These resistors are included with
box. each module.
MMF-302(A): Similar to MMF-300(A). Addressable Monitor Module for Power Supervision Relay: Supervises the power to 4-wire smoke
one zone of conventional two-wire detectors. Requires resettable 24 detectors and notification appliances.
VDC power. Refer to the Device Compatibility Document for listed
compatible devices and quantity limitation. Wiring Requirements
CMF-300(A): Addressable Control Module for one Class B or Class A
zone of supervised polarized Notification Appliances. Mounts directly While shielded wire is not required, it is recommended that all SLC/
to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 DCL wiring be twisted-pair to minimize the effects of electrical interfer-
VDC to power notification appliances. ence. Refer to the panel manual for wiring details.
CRF-300(A): Addressable relay module containing two isolated sets
of Form-C contacts, which operate as a DPDT switch. Mounts directly
to a 4.0" (10.16 cm.) box, surface mount using the SMB500.

DF-60953:D • 3/27/2023— Page 3 of 4


SYSTEM SPECIFICATIONS
System Capacity NFPA Standards
The ES-50X complies with the following NFPA 72 Fire Alarm Systems
• Intelligent Signaling Line Circuits (Digital Comm. Loops).............. 1 requirements:
• Addressable device capacity ....................................................... 50 – LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi-
• Programmable software zones.................................................... 50 sory).
• Annunciators................................................................................ 16 – AUXILIARY (Automatic, Manual and Waterflow) (requires
4XTMF).
Electrical Specifications – REMOTE STATION (Automatic, Manual and Waterflow) (Where a
AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, DACT is not accepted, the alarm, trouble and supervisory relays
auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 may be connected to UL 864 listed transmitters. For reverse
mm2) with 600 V insulation. Non-power-limited, supervised. polarity signaling of alarm and trouble, 4XTMF is required.)
– PROPRIETARY (Automatic, Manual and Waterflow).
Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capac-
ity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH batteries.) – CENTRAL STATION (Automatic, Manual and Waterflow, and
Sprinkler Supervised).
Communication Loop: Supervised and power-limited.
– OT, PSDN (Other Technologies, Packet-switched Data Network)
Notification Appliance Circuits: Terminal Block provides connec-
– IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic).
tions for two NACs, Class B or Class A. Special Application power.
Power-limited, supervised circuitry. Maximum signaling current per cir- – CBC 2007 (Seismic)
cuit: 2.5 amps special application, 250mA regulated. End-of-Line
Resistor: 4.7k ohm, ½ watt (P/N 71252 UL listed) for Class B NAC; Agency Listings and Approvals
system capable of 1.9 kΩ - 22 kΩ ELR range. Refer to the Fire•Lite
The listings and approvals below apply to the basic ES-50X control
Device Compatibility Document for listed compatible devices.
panel. In some cases, certain modules may not be listed by certain
Two Programmable Relays and One Fixed Trouble Relay: Con- approval agencies, or listing may be in process. Consult Fire•Lite for
tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). latest listing status.
Form-C relays, non-power-limited, non-supervised.
ES-50X, ES-50XC, ES-50XI

Cabinet Specifications • UL: S624


• FM approved
Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82
cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) • CSFM: 7165-0075:0500, 7165-0075:0511
wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) • FDNY: COA #2021-TMCOAP-009618-AMD
high x 19.65" (49.91 cm.) wide. ES-50XP
• ETL: 5017286
Shipping Specifications • CSFM: 7165-0075:0511
Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x
22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep.

Temperature and Humidity Ranges


This system meets NFPA requirements for operation at 0 – 49°C/32 –
120°F and at a relative humidity 93% ± 2% RH (noncondensing) at
32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's
standby batteries and the electronic components may be adversely
affected by extreme temperature ranges and humidity. Therefore, it is
recommended that this system and its peripherals be installed in an
environment with a normal room temperature of 15 – 27°C/60 – 80°F.

InnovairFlex™ and LiteSpeed™ are trademarks and AlarmNet®, Fire-Lite®


Alarms, SWIFT®, and System Sensor® are registered trademarks of Honeywell
International Inc. AT&T® is a registered trademark of the AT&T Properties,
L.P.Verizon® is a registered trademark of Verizon Trademark Services LLC.
Microsoft® and Windows® are registered trademarks of the Microsoft Corporation.
©2023 by Honeywell International Inc. All rights reserved. Unauthorized use of this
document is strictly prohibited.

This document is not intended to be used for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.

For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX:(877) 699-4105. Country of Origin: USA
www.firelite.com

Page 4 of 4 — DF-60953:D • 3/27/2023