Cat Electronic Technician 2015A v1.

0
Product Status Report

6/25/2025 8:01 PM

Product Status Report


Parameter Value
Engine Serial Number YAT00759
Equipment ID 3516
Comments

EMCP 4.1
Parameter Value
ECM Part Number 4509596-00
ECM Serial Number 1545E326TY
Software Group Part Number 4555048-00
Software Group Release Date MAR2014
Software Group Description EMCP 4.1 English, v4.4 PROD, 18 March 2014

Logged Diagnostic Codes [Total Operating Hours = 11985.3 hours] - EMCP 4.1
Code Description Occ. SMH First SMH Last RTC First RTC Last
1383-11 Engine was Shut Down 2 6217:40:37 6217:41:32 - -
Hot : Other Failure Mode
3543- 9 Engine Operating State : 3 6217:40:32 6217:40:32 - -
Abnormal Update Rate

Logged Event Codes [Total Operating Hours = 11985.3 hours] - EMCP 4.1
Code Description Occ. SMH First SMH Last RTC First RTC Last
167-17 Charging System 5 6217:40:32 6217:43:32 - -
Potential : Low - least
severe (1)
168-17 Battery Potential / Power 5 6217:40:32 11984:01:3 - -
Input #1 : Low - least 2
severe (1)
970-31 Engine Auxiliary Engine 43 6217:40:32 11984:04:3 - -
Shutdown Switch 2
1664-31 Engine Automatic Start 2 11984:04:3 11984:04:3 - -
Failed 2 2
2440- 1 Generator Average Line- 3 6217:41:15 11984:20:3 - -
Line AC RMS Voltage : 5
Low - most severe (3)
2440-17 Generator Average Line- 3 6217:41:15 11984:20:3 - -
Line AC RMS Voltage : 5
Low - least severe (1)
4007-31 Generator Control not in 99 0:00:02 11984:13:3 - -
Automatic 2
4025-31 Generator Phase 3 6217:41:57 6217:42:40 - -
Sequence Incorrect

Active Diagnostic Codes - EMCP 4.1


Code Description
No Active
Codes

Active Event Codes - EMCP 4.1


Code Description
No Active
Events

Current Totals - EMCP 4.1


Description Value Unit
Total Operating Hours 11985.3 hours

Configuration - EMCP 4.1


Description Value Unit
Analog Input #1 Signal Type Disabled
Analog Input #2 Signal Type Disabled
Analog Input #3 Signal Type Disabled
Analog Input Supply Voltage 5 Volt
Engine Start Fault Protection Activation 30 sec
Delay Time
Crank Duration 12 sec
Crank Cycle Rest Interval 10 sec
Engine Purge Cycle Time with Ignition 0.0 sec
Engine Purge Cycle Time without Ignition 0 sec
Engine Start Sequence Delay Time 0 sec
Maximum Number of Crank Cycles 5
Cooldown Duration 0 min
Start Aid Activation Time 0 sec
Crank Alert Activation Time 0 sec
Crank Terminate RPM 400 rpm
Engine Cooldown Speed Configuration Rated Speed
Engine Operating State Input Configuration Hardwired Input
Fuel Priming Feature Enable Status Disabled
Engine Forced Idle Feature Enable Status Enabled
Emergency Stop Switch Active State High
Configuration
ECU Fault Reset Active Time 0.1 sec
High Battery Voltage Warning Event 30.0 Volts
Threshold
High Battery Voltage Warning Event 10 sec
Notification Delay Time
High Battery Voltage Shutdown Event 32.0 Volts
Threshold
High Battery Voltage Shutdown Event 2 sec
Notification Delay Time
Low Battery Voltage Warning Event 23.4 Volts
Threshold
Low Battery Voltage Warning Event 30 sec
Notification Delay Time
Low Battery Charging System Voltage 25.0 Volts
Warning Event Threshold
Low Battery Charging System Voltage 30 sec
Warning Event Notification Delay Time
Low Cranking Voltage Warning Event 21.0 Volts
Threshold
Low Cranking Voltage Warning Event 10 sec
Notification Delay Time
Customer Password Security Level to 3-Factory, Single Use
Reset Crank/Start Counters
Digital Input #1 Usage Type System Event
Digital Input #1 Active State Configuration Low
Event Input Function #1 Event Notification 0 sec
Delay Time
Event Input Function #1 Suspect Engine Coolant Level
Parameter Number
Event Input Function #1 Failure Mode Low Shutdown
Identifier
Digital Input #2 Usage Type System Event
Digital Input #2 Active State Configuration Low
Event Input Function #2 Event Notification 0 sec
Delay Time
Event Input Function #2 Suspect Engine Coolant Level
Parameter Number
Event Input Function #2 Failure Mode Low Warning
Identifier
Digital Input #3 Usage Type Disabled
Digital Input #4 Usage Type Disabled
Digital Input #5 Usage Type Disabled
Digital Input #6 Usage Type System Event
Digital Input #6 Active State Configuration Low
Event Input Function #6 Event Notification 0 sec
Delay Time
Event Input Function #6 Suspect Generator Circuit Breaker Open
Parameter Number
Event Input Function #6 Failure Mode Condition Exists
Identifier
Engine Coolant Temperature Sensor Data Link
Configuration
High Engine Coolant Temperature Warning 216 Deg F
Event Threshold
High Engine Coolant Temperature Warning 2 sec
Event Notification Delay Time
High Engine Coolant Temperature 225 Deg F
Shutdown Event Threshold
High Engine Coolant Temperature 10 sec
Shutdown Event Notification Delay Time
Low Engine Coolant Temperature Warning 41 Deg F
Event Threshold
Low Engine Coolant Temperature Warning 10 sec
Event Notification Delay Time
Engine Oil Pressure Sensor Configuration Data Link
Low Engine Oil Pressure Warning Event 35 psi
Threshold
Low Idle Low Engine Oil Pressure Warning 15 psi
Event Threshold
Low Engine Oil Pressure Warning Event 0 sec
Notification Delay Time
Low Engine Oil Pressure Shutdown Event 30 psi
Threshold
Low Idle Low Engine Oil Pressure 10 psi
Shutdown Event Threshold
Low Engine Oil Pressure Shutdown Event 0 sec
Notification Delay Time
Low Engine Oil Pressure Step Speed 1200 rpm
Flywheel Teeth 183
Engine Overspeed Setpoint 1770 rpm
Engine Underspeed Warning Event 1290 rpm
Threshold
Engine Underspeed Warning Event 10.0 sec
Notification Delay Time
Engine Underspeed Shutdown Event 1230 rpm
Threshold
Engine Underspeed Shutdown Event 10.0 sec
Notification Delay Time
Engine Speed Sensor Configuration Sensor
Generator Drive Ratio 1.000 Ratio
Engine Speed Sensor Diagnostic Activate Hard Shutdown Condition
Response Configuration
Engine Speed Sensor Diagnostic Audible Yes
Alert
Engine Speed Sensor Diagnostic Breaker No
#1 Trip
Engine Speed Sensor Diagnostic Breaker No
#2 Trip
Primary Data Link Diagnostic Response Activate Warning Condition
Configuration
Primary Data Link Diagnostic Audible Alert No
Primary Data Link Diagnostic Breaker #1 No
Trip
Primary Data Link Diagnostic Breaker #2 No
Trip
Battery Charger Failure Diagnostic Activate Warning Condition
Response Configuration
Battery Charger Failure Diagnostic Audible Yes
Alert
Engine Controller Not Responding Disable Condition
Diagnostic Response Configuration
Engine Controller Not Responding No
Diagnostic Audible Alert
Engine Controller Not Responding No
Diagnostic Breaker #1 Trip
Engine Controller Not Responding No
Diagnostic Breaker #2 Trip
Analog Input #1 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #1 Diagnostic Audible Alert No
Analog Input #1 Diagnostic Breaker #1 Trip No
Analog Input #1 Diagnostic Breaker #2 Trip No
Analog Input #2 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #2 Diagnostic Audible Alert No
Analog Input #2 Diagnostic Breaker #1 Trip No
Analog Input #2 Diagnostic Breaker #2 Trip No
Analog Input #3 Diagnostic Response Activate Warning Condition
Configuration
Analog Input #3 Diagnostic Audible Alert No
Analog Input #3 Diagnostic Breaker #1 Trip No
Analog Input #3 Diagnostic Breaker #2 Trip No
Air Damper Closed Event Response Hard Shutdown & Active Only
Configuration Condition
Air Damper Closed Event Audible Alert Yes
Emergency Stop Activated Event Activate Hard Shutdown Condition
Response Configuration
Emergency Stop Activated Event Audible Yes
Alert
Emergency Stop Activated Event Breaker No
#1 Trip
Emergency Stop Activated Event Breaker No
#2 Trip
High Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
High Engine Coolant Level Warning Event Yes
Audible Alert
High Engine Coolant Level Warning Event No
Breaker #1 Trip
High Engine Coolant Level Warning Event No
Breaker #2 Trip
High Engine Coolant Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Coolant Level Shutdown Yes
Event Audible Alert
High Engine Coolant Level Shutdown No
Event Breaker #1 Trip
High Engine Coolant Level Shutdown No
Event Breaker #2 Trip
Low Engine Coolant Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Coolant Level Warning Event Yes
Audible Alert
Low Engine Coolant Level Warning Event No
Breaker #1 Trip
Low Engine Coolant Level Warning Event No
Breaker #2 Trip
Low Engine Coolant Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Coolant Level Shutdown Event Yes
Audible Alert
Low Engine Coolant Level Shutdown Event No
Breaker #1 Trip
Low Engine Coolant Level Shutdown Event No
Breaker #2 Trip
High Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Coolant Temperature Warning Yes
Event Audible Alert
High Engine Coolant Temperature Warning No
Event Breaker #1 Trip
High Engine Coolant Temperature Warning No
Event Breaker #2 Trip
High Engine Coolant Temperature Warning Yes
Event Fault Protection Timer
High Engine Coolant Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Engine Coolant Temperature Yes
Shutdown Event Audible Alert
High Engine Coolant Temperature No
Shutdown Event Breaker #1 Trip
High Engine Coolant Temperature No
Shutdown Event Breaker #2 Trip
High Engine Coolant Temperature Yes
Shutdown Event Fault Protection Timer
Low Engine Coolant Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Coolant Temperature Warning Yes
Event Audible Alert
Low Engine Coolant Temperature Warning No
Event Breaker #1 Trip
Low Engine Coolant Temperature Warning No
Event Breaker #2 Trip
Low Engine Coolant Temperature Warning No
Event Fault Protection Timer
Engine Failure To Start Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Failure To Start Shutdown Event Yes
Audible Alert
Engine Failure To Start Shutdown Event No
Breaker #1 Trip
Engine Failure To Start Shutdown Event No
Breaker #2 Trip
High Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
High Engine Oil Level Warning Event Yes
Audible Alert
High Engine Oil Level Warning Event No
Breaker #1 Trip
High Engine Oil Level Warning Event No
Breaker #2 Trip
High Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Engine Oil Level Shutdown Event Yes
Audible Alert
High Engine Oil Level Shutdown Event No
Breaker #1 Trip
High Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Level Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Level Warning Event Yes
Audible Alert
Low Engine Oil Level Warning Event No
Breaker #1 Trip
Low Engine Oil Level Warning Event No
Breaker #2 Trip
Low Engine Oil Level Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Level Shutdown Event Yes
Audible Alert
Low Engine Oil Level Shutdown Event No
Breaker #1 Trip
Low Engine Oil Level Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Activate Warning Condition
Response Configuration
Low Engine Oil Pressure Warning Event Yes
Audible Alert
Low Engine Oil Pressure Warning Event No
Breaker #1 Trip
Low Engine Oil Pressure Warning Event No
Breaker #2 Trip
Low Engine Oil Pressure Warning Event Yes
Fault Protection Timer
Low Engine Oil Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Engine Oil Pressure Shutdown Event Yes
Audible Alert
Low Engine Oil Pressure Shutdown Event No
Breaker #1 Trip
Low Engine Oil Pressure Shutdown Event No
Breaker #2 Trip
Low Engine Oil Pressure Shutdown Event Yes
Fault Protection Timer
High Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
High Engine Oil Temperature Warning Yes
Event Audible Alert
High Engine Oil Temperature Warning No
Event Breaker #1 Trip
High Engine Oil Temperature Warning No
Event Breaker #2 Trip
High Engine Oil Temperature Warning No
Event Fault Protection Timer
High Engine Oil Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Engine Oil Temperature Shutdown Yes
Event Audible Alert
High Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
High Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
High Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Low Engine Oil Temperature Warning Activate Warning Condition
Event Response Configuration
Low Engine Oil Temperature Warning Yes
Event Audible Alert
Low Engine Oil Temperature Warning No
Event Breaker #1 Trip
Low Engine Oil Temperature Warning No
Event Breaker #2 Trip
Low Engine Oil Temperature Warning Yes
Event Fault Protection Timer
Low Engine Oil Temperature Shutdown Disable Condition
Event Response Configuration
Low Engine Oil Temperature Shutdown No
Event Audible Alert
Low Engine Oil Temperature Shutdown No
Event Breaker #1 Trip
Low Engine Oil Temperature Shutdown No
Event Breaker #2 Trip
Low Engine Oil Temperature Shutdown No
Event Fault Protection Timer
Unexpected Engine Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Unexpected Engine Shutdown Event Yes
Audible Alert
Unexpected Engine Shutdown Event No
Breaker #1 Trip
Unexpected Engine Shutdown Event No
Breaker #2 Trip
Engine Overspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Overspeed Shutdown Event Yes
Audible Alert
Engine Overspeed Shutdown Event No
Breaker #1 Trip
Engine Overspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Warning Event Activate Warning Condition
Response Configuration
Engine Underspeed Warning Event Audible Yes
Alert
Engine Underspeed Warning Event No
Breaker #1 Trip
Engine Underspeed Warning Event No
Breaker #2 Trip
Engine Underspeed Warning Event Fault Yes
Protection Timer
Engine Underspeed Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Engine Underspeed Shutdown Event Yes
Audible Alert
Engine Underspeed Shutdown Event No
Breaker #1 Trip
Engine Underspeed Shutdown Event No
Breaker #2 Trip
Engine Underspeed Shutdown Event Fault Yes
Protection Timer
High Exhaust Temperature Warning Event Disable Condition
Response Configuration
High Exhaust Temperature Warning Event No
Audible Alert
High Exhaust Temperature Warning Event No
Breaker #1 Trip
High Exhaust Temperature Warning Event No
Breaker #2 Trip
High Exhaust Temperature Warning Event No
Fault Protection Timer
High Exhaust Temperature Shutdown Activate Hard Shutdown Condition
Event Response Configuration
High Exhaust Temperature Shutdown Yes
Event Audible Alert
High Exhaust Temperature Shutdown No
Event Breaker #1 Trip
High Exhaust Temperature Shutdown No
Event Breaker #2 Trip
High Exhaust Temperature Shutdown No
Event Fault Protection Timer
Low Exhaust Temperature Warning Event Activate Warning Condition
Response Configuration
Low Exhaust Temperature Warning Event Yes
Audible Alert
Low Exhaust Temperature Warning Event No
Breaker #1 Trip
Low Exhaust Temperature Warning Event No
Breaker #2 Trip
Low Exhaust Temperature Warning Event Yes
Fault Protection Timer
Low Exhaust Temperature Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Exhaust Temperature Shutdown Event Yes
Audible Alert
Low Exhaust Temperature Shutdown Event No
Breaker #1 Trip
Low Exhaust Temperature Shutdown Event No
Breaker #2 Trip
Low Exhaust Temperature Shutdown Event Yes
Fault Protection Timer
High Fuel Level Warning Event Response Activate Warning Condition
Configuration
High Fuel Level Warning Event Audible Yes
Alert
High Fuel Level Warning Event Breaker #1 No
Trip
High Fuel Level Warning Event Breaker #2 No
Trip
High Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
High Fuel Level Shutdown Event Audible Yes
Alert
High Fuel Level Shutdown Event Breaker No
#1 Trip
High Fuel Level Shutdown Event Breaker No
#2 Trip
Low Fuel Level Warning Event Response Activate Warning Condition
Configuration
Low Fuel Level Warning Event Audible Yes
Alert
Low Fuel Level Warning Event Breaker #1 No
Trip
Low Fuel Level Warning Event Breaker #2 No
Trip
Low Fuel Level Shutdown Event Response Activate Hard Shutdown Condition
Configuration
Low Fuel Level Shutdown Event Audible Yes
Alert
Low Fuel Level Shutdown Event Breaker No
#1 Trip
Low Fuel Level Shutdown Event Breaker No
#2 Trip
External Tank High Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank High Fuel Level Warning Yes
Event Audible Alert
External Tank High Fuel Level Warning No
Event Breaker #1 Trip
External Tank High Fuel Level Warning No
Event Breaker #2 Trip
External Tank High Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank High Fuel Level Shutdown Yes
Event Audible Alert
External Tank High Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank High Fuel Level Shutdown No
Event Breaker #2 Trip
External Tank Low Fuel Level Warning Activate Warning Condition
Event Response Configuration
External Tank Low Fuel Level Warning Yes
Event Audible Alert
External Tank Low Fuel Level Warning No
Event Breaker #1 Trip
External Tank Low Fuel Level Warning No
Event Breaker #2 Trip
External Tank Low Fuel Level Shutdown Activate Hard Shutdown Condition
Event Response Configuration
External Tank Low Fuel Level Shutdown Yes
Event Audible Alert
External Tank Low Fuel Level Shutdown No
Event Breaker #1 Trip
External Tank Low Fuel Level Shutdown No
Event Breaker #2 Trip
Fuel Leak Event Response Configuration Activate Warning Condition
Fuel Leak Event Audible Alert Yes
Fuel Leak Event Breaker #1 Trip No
Fuel Leak Event Breaker #2 Trip No
High Gas Pressure Warning Event Activate Warning Condition
Response Configuration
High Gas Pressure Warning Event Audible Yes
Alert
High Gas Pressure Warning Event Breaker No
#1 Trip
High Gas Pressure Warning Event Breaker No
#2 Trip
High Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
High Gas Pressure Shutdown Event Yes
Audible Alert
High Gas Pressure Shutdown Event No
Breaker #1 Trip
High Gas Pressure Shutdown Event No
Breaker #2 Trip
Low Gas Pressure Warning Event Activate Warning Condition
Response Configuration
Low Gas Pressure Warning Event Audible Yes
Alert
Low Gas Pressure Warning Event Breaker No
#1 Trip
Low Gas Pressure Warning Event Breaker No
#2 Trip
Low Gas Pressure Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Low Gas Pressure Shutdown Event Yes
Audible Alert
Low Gas Pressure Shutdown Event No
Breaker #1 Trip
Low Gas Pressure Shutdown Event No
Breaker #2 Trip
Engine Intake Manifold Charge Activate Warning Condition
Combustion Event Response Configuration
Engine Intake Manifold Charge Yes
Combustion Event Audible Alert
Engine Intake Manifold Charge No
Combustion Event Breaker #1 Trip
Engine Intake Manifold Charge No
Combustion Event Breaker #2 Trip
Engine Intake Manifold Charge Yes
Combustion Event Fault Protection Timer
Remote Emergency Stop Activated Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Remote Emergency Stop Activated Yes
Shutdown Event Audible Alert
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #1 Trip
Remote Emergency Stop Activated Yes
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
High Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
High Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Warning Event Fault Protection Timer
High Generator Bearing #1 Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
High Generator Bearing #1 Temperature Yes
Shutdown Event Audible Alert
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
High Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Low Generator Bearing #1 Temperature Activate Warning Condition
Warning Event Response Configuration
Low Generator Bearing #1 Temperature Yes
Warning Event Audible Alert
Low Generator Bearing #1 Temperature No
Warning Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Warning Event Breaker #2 Trip
Low Generator Bearing #1 Temperature Yes
Warning Event Fault Protection Timer
Low Generator Bearing #1 Temperature Disable Condition
Shutdown Event Response Configuration
Low Generator Bearing #1 Temperature No
Shutdown Event Audible Alert
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #1 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Breaker #2 Trip
Low Generator Bearing #1 Temperature No
Shutdown Event Fault Protection Timer
Generator Overcurrent Warning Event Activate Warning Condition
Response Configuration
Generator Overcurrent Warning Event Yes
Audible Alert
Generator Overcurrent Warning Event No
Breaker #1 Trip
Generator Overcurrent Warning Event No
Breaker #2 Trip
Generator Overcurrent Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Overcurrent Shutdown Event Yes
Audible Alert
Generator Overcurrent Shutdown Event No
Breaker #1 Trip
Generator Overcurrent Shutdown Event No
Breaker #2 Trip
Generator Over Frequency Warning Event Activate Warning Condition
Response Configuration
Generator Over Frequency Warning Event Yes
Audible Alert
Generator Over Frequency Warning Event No
Breaker #1 Trip
Generator Over Frequency Warning Event No
Breaker #2 Trip
Generator Over Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Over Frequency Shutdown Yes
Event Audible Alert
Generator Over Frequency Shutdown No
Event Breaker #1 Trip
Generator Over Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Warning Activate Warning Condition
Event Response Configuration
Generator Under Frequency Warning Yes
Event Audible Alert
Generator Under Frequency Warning No
Event Breaker #1 Trip
Generator Under Frequency Warning No
Event Breaker #2 Trip
Generator Under Frequency Warning Yes
Event Fault Protection Timer
Generator Under Frequency Shutdown Activate Hard Shutdown Condition
Event Response Configuration
Generator Under Frequency Shutdown Yes
Event Audible Alert
Generator Under Frequency Shutdown No
Event Breaker #1 Trip
Generator Under Frequency Shutdown No
Event Breaker #2 Trip
Generator Under Frequency Shutdown Yes
Event Fault Protection Timer
Generator Over Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Over Voltage Warning Event Yes
Audible Alert
Generator Over Voltage Warning Event No
Breaker #1 Trip
Generator Over Voltage Warning Event No
Breaker #2 Trip
Generator Over Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Over Voltage Shutdown Event Yes
Audible Alert
Generator Over Voltage Shutdown Event No
Breaker #1 Trip
Generator Over Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Activate Warning Condition
Response Configuration
Generator Under Voltage Warning Event Yes
Audible Alert
Generator Under Voltage Warning Event No
Breaker #1 Trip
Generator Under Voltage Warning Event No
Breaker #2 Trip
Generator Under Voltage Warning Event Yes
Fault Protection Timer
Generator Under Voltage Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Under Voltage Shutdown Event Yes
Audible Alert
Generator Under Voltage Shutdown Event No
Breaker #1 Trip
Generator Under Voltage Shutdown Event No
Breaker #2 Trip
Generator Under Voltage Shutdown Event Yes
Fault Protection Timer
Earth Fault Event Response Configuration Activate Hard Shutdown Condition
Earth Fault Event Audible Alert Yes
Earth Fault Event Breaker #1 Trip No
Earth Fault Event Breaker #2 Trip No
Generator Winding #1 High Temperature Activate Warning Condition
Warning Event Response Configuration
Generator Winding #1 High Temperature Yes
Warning Event Audible Alert
Generator Winding #1 High Temperature No
Warning Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Warning Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Warning Event Fault Protection Timer
Generator Winding #1 High Temperature Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Generator Winding #1 High Temperature Yes
Shutdown Event Audible Alert
Generator Winding #1 High Temperature No
Shutdown Event Breaker #1 Trip
Generator Winding #1 High Temperature No
Shutdown Event Breaker #2 Trip
Generator Winding #1 High Temperature No
Shutdown Event Fault Protection Timer
Generator High Power Warning Event Activate Warning Condition
Response Configuration
Generator High Power Warning Event Yes
Audible Alert
Generator High Power Warning Event No
Breaker #1 Trip
Generator High Power Warning Event No
Breaker #2 Trip
Generator Reverse Power Warning Event Activate Warning Condition
Response Configuration
Generator Reverse Power Warning Event Yes
Audible Alert
Generator Reverse Power Warning Event No
Breaker #1 Trip
Generator Reverse Power Warning Event No
Breaker #2 Trip
Generator Reverse Power Shutdown Event Activate Hard Shutdown Condition
Response Configuration
Generator Reverse Power Shutdown Event Yes
Audible Alert
Generator Reverse Power Shutdown Event No
Breaker #1 Trip
Generator Reverse Power Shutdown Event No
Breaker #2 Trip
High Battery Voltage Warning Event Activate Warning Condition
Response Configuration
High Battery Voltage Warning Event Yes
Audible Alert
High Battery Voltage Warning Event No
Breaker #1 Trip
High Battery Voltage Warning Event No
Breaker #2 Trip
High Battery Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
High Battery Voltage Shutdown Event Yes
Audible Alert
High Battery Voltage Shutdown Event No
Breaker #1 Trip
High Battery Voltage Shutdown Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Activate Warning Condition
Response Configuration
Low Battery Voltage Warning Event Yes
Audible Alert
Low Battery Voltage Warning Event No
Breaker #1 Trip
Low Battery Voltage Warning Event No
Breaker #2 Trip
Low Battery Voltage Warning Event Fault No
Protection Timer
Low Battery Charging System Voltage Disable Condition
Warning Event Response Configuration
Low Battery Charging System Voltage No
Warning Event Audible Alert
Low Battery Charging System Voltage No
Warning Event Breaker #1 Trip
Low Battery Charging System Voltage No
Warning Event Breaker #2 Trip
Low Battery Charging System Voltage No
Warning Event Fault Protection Timer
Generator Breaker Open Event Response Active Only Condition
Configuration
Generator Breaker Open Event Audible No
Alert
Generator Breaker Closed Event Response Active Only Condition
Configuration
Generator Breaker Closed Event Audible No
Alert
Engine In Cooldown Event Response Active Only Condition
Configuration
Engine In Cooldown Event Audible Alert No
Engine Speed-Generator Output Freq Activate Warning Condition
Mismatch Warning Event Response Config
Engine Speed-Generator Output Freq Yes
Mismatch Warning Event Audible Alert
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #1 Trip
Engine Speed-Generator Output Freq No
Mismatch Warning Event Breaker #2 Trip
Generator Control Not in Automatic Activate Warning Condition
Warning Event Response Configuration
Generator Control Not in Automatic Yes
Warning Event Audible Alert
Earth Leakage Event Response Activate Hard Shutdown Condition
Configuration
Earth Leakage Event Audible Alert Yes
Earth Leakage Event Breaker #1 Trip No
Earth Leakage Event Breaker #2 Trip No
Low Cranking Voltage Warning Event Disable Condition
Response Configuration
Low Cranking Voltage Warning Event No
Audible Alert
Low Cranking Voltage Warning Event No
Breaker #1 Trip
Low Cranking Voltage Warning Event No
Breaker #2 Trip
Analog Input #1 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #1 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #1 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #1 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #2 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #2 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #2 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter High No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter High Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter High Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter High No
Shutdown Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Warning Condition
Warning Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Warning Event Audible Alert
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Warning Event Fault Protection Timer
Analog Input #3 Custom Parameter Low Activate Hard Shutdown Condition
Shutdown Event Response Configuration
Analog Input #3 Custom Parameter Low Yes
Shutdown Event Audible Alert
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #1 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Breaker #2 Trip
Analog Input #3 Custom Parameter Low No
Shutdown Event Fault Protection Timer
Custom Event #1 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #1 Condition Exists Event No
Audible Alert
Custom Event #1 Condition Exists Event No
Breaker #1 Trip
Custom Event #1 Condition Exists Event No
Breaker #2 Trip
Custom Event #1 Condition Exists Event No
Fault Protection Timer
Custom Event #2 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #2 Condition Exists Event No
Audible Alert
Custom Event #2 Condition Exists Event No
Breaker #1 Trip
Custom Event #2 Condition Exists Event No
Breaker #2 Trip
Custom Event #2 Condition Exists Event No
Fault Protection Timer
Custom Event #3 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #3 Condition Exists Event No
Audible Alert
Custom Event #3 Condition Exists Event No
Breaker #1 Trip
Custom Event #3 Condition Exists Event No
Breaker #2 Trip
Custom Event #3 Condition Exists Event No
Fault Protection Timer
Custom Event #4 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #4 Condition Exists Event No
Audible Alert
Custom Event #4 Condition Exists Event No
Breaker #1 Trip
Custom Event #4 Condition Exists Event No
Breaker #2 Trip
Custom Event #4 Condition Exists Event No
Fault Protection Timer
Custom Event #5 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #5 Condition Exists Event No
Audible Alert
Custom Event #5 Condition Exists Event No
Breaker #1 Trip
Custom Event #5 Condition Exists Event No
Breaker #2 Trip
Custom Event #5 Condition Exists Event No
Fault Protection Timer
Custom Event #6 Condition Exists Event Active Only Condition
Response Configuration
Custom Event #6 Condition Exists Event No
Audible Alert
Custom Event #6 Condition Exists Event No
Breaker #1 Trip
Custom Event #6 Condition Exists Event No
Breaker #2 Trip
Custom Event #6 Condition Exists Event No
Fault Protection Timer
Fuel Fill/Drain Feature Enable Status Disabled
Fuel Fill Activation Tank Level Percentage 5.0 %
Threshold
Fuel Fill Deactivation Tank Level 5.0 %
Percentage Threshold
Generator Connection Configuration Wye (or Star) Connection
Generator Potential Transformer Primary 1 Volts
Winding Rating
Generator Potential Transformer 1 Volts
Secondary Winding Rating
Generator Current Transformer Primary 3500 Amps
Winding Rating
Generator Current Transformer Secondary 5 Amps
Winding Rating
Number of Generator Poles 4 Poles
Generator Rated Frequency 50 Hz
Generator Rated Voltage 415 Volts
Generator Rated Power 1600 kW
Generator Rated Apparent Power 2000 kVA
Maximum Generator Voltage Output Bias 15 %
Percentage
Generator Over Frequency Warning Event 105.0 %
Percentage Threshold
Generator Over Frequency Warning Event 20 sec
Notification Delay Time
Generator Over Frequency Shutdown 110.0 %
Event Percentage Threshold
Generator Over Frequency Shutdown 20 sec
Event Notification Delay Time
Generator Under Frequency Warning 95.0 %
Event Percentage Threshold
Generator Under Frequency Warning 20 sec
Event Notification Delay Time
Generator Under Frequency Shutdown 90.0 %
Event Percentage Threshold
Generator Under Frequency Shutdown 25 sec
Event Notification Delay Time
Generator Over Voltage Warning Event 105 %
Percentage Threshold
Generator Over Voltage Warning Event 10 sec
Notification Delay Time
Generator Over Voltage Shutdown Event 120 %
Percentage Threshold
Generator Over Voltage Shutdown Event 20 sec
Notification Delay Time
Generator Under Voltage Warning Event 90 %
Percentage Threshold
Generator Under Voltage Warning Event 10 sec
Notification Delay Time
Generator Under Voltage Shutdown Event 80 %
Percentage Threshold
Generator Under Voltage Shutdown Event 25 sec
Notification Delay Time
Electronic Control Module Reduced Power Disabled
Mode Enable Status
Electronic Control Module Reduced Power 30 min
Mode Delay Time
Relay Output #1 Usage Type Command/Status Parameter
Relay Output #1 Command/Status Starter Motor Relay
Parameter Data Identification
Relay Output #2 Usage Type Command/Status Parameter
Relay Output #2 Command/Status Fuel Control Relay
Parameter Data Identification
Relay Output #3 Usage Type Disabled
Relay Output #4 Usage Type Command/Status Parameter
Relay Output #4 Command/Status Common Shutdown
Parameter Data Identification
Relay Output #5 Usage Type Command/Status Parameter
Relay Output #5 Command/Status Common Shutdown
Parameter Data Identification
Relay Output #6 Usage Type Command/Status Parameter
Relay Output #6 Command/Status Engine Started
Parameter Data Identification
Voltage Regulator Control Source External Control
Configuration
Engine Serial Number Not Programmed
Display Pressure Units Configuration kPa
Display Temperature Units Configuration Degrees Centigrade (Celsius)

Digital Voltage Regulator


Parameter Value
ECM Part Number 3147755-00
ECM Serial Number 34616050GD
Software Group Part Number 3184763-01
Software Group Release Date NOV2007
Software Group Description Regulator Software

Logged Diagnostic Codes [Diagnostic Clock = 11985 hours] - Digital Voltage Regulator
Code Description Occ. SMH First SMH Last RTC First RTC Last
No Logged
Diagnostic
Codes

Logged Event Codes [Diagnostic Clock = 11985 hours] - Digital Voltage Regulator
Code Description Occ. SMH First SMH Last RTC First RTC Last
2456- 1 Generator Total Reactive 6 1:30:00 516:06:00 10/7/2012 10/6/2013
Power : Low - most 8:33:08 AM 2:38:18 AM
severe (3)

Active Diagnostic Codes - Digital Voltage Regulator


Code Description
No Active
Codes

Active Event Codes - Digital Voltage Regulator


Code Description
No Active
Events

Configuration - Digital Voltage Regulator


Description Value Unit
Voltage Regulator Power Input Frequency 50 Hz
Configuration
Potential Transformer Primary Winding 120 Volts
Rating
Potential Transformer Secondary Winding 120 Volts
Rating
Current Transformer Primary Winding 3500 Amps
Rating
Current Transformer Secondary Winding 5 Amps
Rating
Generator Connection Configuration Three Phase
Generator Rated Frequency 50 Hz
Generator Rated Voltage 415 Volts
Generator Rated Current 2700 Amps
Voltage Regulator Loss of Sensing 2.0 sec
Shutdown Event Notification Delay Time
Generator Rotating Diode Monitor 2.0 Amps
Shutdown Event Current Threshold
Generator Reverse VAr Shutdown Event 20 %
Percentage Threshold
Generator Reverse VAr Shutdown Event 9.0 sec
Notification Delay Time
Generator Reverse VAr Shutdown Event Activate Soft Shutdown Condition
Response Configuration
Generator Over Voltage Shutdown Event 110 %
Percentage Threshold
Generator Over Voltage Shutdown Event 10 sec
Notification Delay Time
Generator Over Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
Generator Under Voltage Shutdown Event 80 %
Percentage Threshold
Generator Under Voltage Shutdown Event 15 sec
Notification Delay Time
Generator Under Voltage Shutdown Event Activate Soft Shutdown Condition
Response Configuration
Voltage Regulator Over Excitation 7.0 Amps
Shutdown Event Threshold
Voltage Regulator Over Excitation 10.0 sec
Shutdown Event Notification Delay Time
Voltage Regulator Over Excitation Definite Time
Shutdown Event Notification Delay Type
Voltage Regulator Fault Reset Switch Activate Warning Condition
Diagnostic Response Configuration
Generator Nominal Output Voltage 415 Volts
Voltage Regulator Corner (Knee) 49.8 Hz
Frequency
Voltage Regulator Deviation From Corner 5.0 Hz
(Knee) Frequency
Voltage Regulator Volts/Hz Slope 1 2.0 V/Hz
Voltage Regulator Volts/Hz Slope 2 2.0 V/Hz
Voltage Regulator Minimum Voltage 50.0 %
Setpoint Percentage
Voltage Regulator Minimum Frequency 33.0 Hz
Threshold
Voltage Regulator Maximum Droop 2.0 %
Percentage
Voltage Regulator Voltage (IR) 2.0 %
Compensation Percentage
Voltage Regulator Starting Time 5.0 sec
Voltage Regulator Starting Voltage Percent 10.0 %
Voltage Regulator Noise Filter Time 0.00 sec
Constant
Voltage Regulation Proportional Gain 20.00 %
Percentage
Voltage Regulation Integral Gain 60.00 %
Percentage
Voltage Regulation Derivative Gain 3.00 %
Percentage
Voltage Regulator Gain Setting Selection 7
Number
Voltage Regulator Gain Setting Type User Defined
Configuration
Voltage Regulator Loop Gain Percentage 5.00 %
Maximum Generator Voltage Output Bias 15 %
Percentage Setpoint
Desired Voltage Input Configuration Invalid Data
Generator Nominal Output Power Factor 1.00
Voltage Regulator Nominal Reactive Power 0.0 %
Percentage
Generator Power Factor Controller Loop 0.30 %
Gain Percentage
Generator Power Factor Controller Integral 0.50 %
Gain Percentage
Voltage Regulator Load Compensation Voltage Droop
Type Configuration
Voltage Regulator Power Factor/VAr Data Invalid
Controller Mode Selection
Voltage Regulator Desired Power Factor Lagging
Configuration
Generator VAr Controller Loop Gain 0.25 %
Percentage
Generator VAr Controller Integral Gain 0.50 %
Percentage
VAr / Power Factor Control Input Invalid Data
Configuration

3516B Engine - Genset #1 (YAT00759)


Parameter Value
Equipment ID 3516
Engine Serial Number YAT00759
ECM Serial Number 0452B161JP
Personality Module Part Number 3985091-00
Personality Module Release Date JUL12
Personality Module Description GENSET

Logged Diagnostic Codes [Diagnostic Clock = 11987.2468 hours] - 3516B Engine - Genset #1
(YAT00759)
Code Description Occ. First Last
91- 8 Throttle Position Sensor : Abnormal Frequency, 38 11984 11986
Pulse Width, or Period
101- 3 Crankcase Air Pressure Sensor : Voltage Above 2 11986 11986
Normal
273- 3 Turbocharger Outlet Pressure Sensor : Voltage 127 11985 11986
Above Normal
274- 3 Atmospheric Pressure Sensor : Voltage Above 2 11986 11986
Normal
275- 3 Right Turbocharger Inlet Pressure Sensor : 2 11984 11986
Voltage Above Normal
276- 3 Left Turbocharger Inlet Pressure Sensor : Voltage 2 11984 11986
Above Normal
828- 8 Right Exhaust Temperature Sensor : Abnormal 1 11986 11986
Frequency, Pulse Width, or Period
100- 3 Engine Oil Pressure Sensor : Voltage Above 11 11986 11986
Normal
100- 2 Engine Oil Pressure Sensor : Erratic, Intermittent, 1 11986 11986
or Incorrect
542- 2 Engine Oil Pressure Sensor - Before Oil Filter : 1 11986 11986
Erratic, Intermittent, or Incorrect
1- 5 Cylinder #1 Injector : Current Below Normal 1 11986 11986
175- 3 Engine Oil Temperature Sensor : Voltage Above 8 11986 11986
Normal
337- 2 Remote Emergency Stop Switch : Erratic, 23 11986 11986
Intermittent, or Incorrect
247- 9 SAE J1939 Data Link : Abnormal Update Rate 8 11984 11985
279- 3 Aftercooler Coolant Temperature Sensor (Front) : 1 11984 11984
Voltage Above Normal

Logged Event Codes [Diagnostic Clock = 11987.2468 hours] - 3516B Engine - Genset #1
(YAT00759)
Code Description Occ. First Last
E009 (2) High Altitude Derate 2 11986 11986
E038 (1) Low Engine Coolant Temperature Warning 1 11984 11984
E099 (1) Engine Oil Filter Restriction Warning 1 11984 11984
E264 (3) Emergency Stop Activated 16 11984 11986
Active Diagnostic Codes - 3516B Engine - Genset #1 (YAT00759)
Code Description
No Active
Codes

Active Event Codes - 3516B Engine - Genset #1 (YAT00759)


Code Description
E009 (2) High Altitude Derate

Current Totals - 3516B Engine - Genset #1 (YAT00759)


Description Value Unit
Total Time 11987 hours
Total Fuel 516790 gal

Configuration - 3516B Engine - Genset #1 (YAT00759)


Description Value Unit
Equipment ID 3516
Engine Serial Number YAT00759
ECM Serial Number 0452B161JP
Personality Module Part Number 3985091-00
Personality Module Release Date JUL12
Rated Engine Speed 1500 rpm
Fuel Ratio Control Offset 0
Acceleration Delay Time 0 sec
Engine Acceleration Rate 250 rpm/s
Low Idle Speed 900 rpm
Cooldown Speed 900 rpm
Cooldown Duration 0 min
Engine Pre-Lube Duration 0 sec
Engine Pre-Lube System Configuration Automatic
Engine Continuous Pre-Lube Interval 0 min
Crank Duration 0 sec
Maximum Number of Crank Cycles 0
Crank Terminate RPM 400 rpm
Engine Speed Droop 0.0 %
Rated Fuel Position 25.200 mm
Fuel Correction Factor 0 %
Governor Gain Factor #1 26214
Governor Minimum Stability Factor #1 629
Governor Maximum Stability Factor #1 7864
FLS 0
FTS 0
Air Shutoff Disabled
Air Intake Shutoff Detection Installation Unavailable
Status
Ether Control Disabled
Engine Cooling System Config SCAC (Separate Circuit Aftercooled)
Cold Cylinder Cutout Disabled
Direct Fuel Control Mode Disabled
Desired Speed Input Configuration PWM
Throttle Air Pressure Sensor Installation Unavailable
Status
Throttle Input Low Idle Duty Cycle Setpoint Unavailable %
Throttle Input High Idle Duty Cycle Setpoint Unavailable %
Secondary Desired Speed Input PWM
Configuration
Fuel Enable Input Configuration CAN Input
Secondary Fuel Enable Input Enable Enabled
Status
Coolant Level Sensor Not Installed
Aftercooler Coolant Level Sensor Not Installed
Installation Status
Cat Data Link #2 Identifier Engine Control #1
Inlet Air Temperature Sensor Not Installed
Engine Oil Temperature Sensor Installation Installed
Status
Total Tattletale 21

Lifetime: Time vs Engine Speed - 3516B Engine - Genset #1 (YAT00759)


Engine Speed( rpm ) hours %
<400 2.75 0.01
400-499 0.75 0.00
500-599 0.75 0.00
600-699 0.70 0.00
700-799 0.65 0.00
800-899 1.75 0.01
900-999 1.60 0.01
1000-1099 0.50 0.00
1100-1199 0.50 0.00
1200-1299 0.45 0.00
1300-1399 0.45 0.00
1400-1499 18041.45 79.10
1500-1599 4078.50 17.88
1600-1699 0.05 0.00
1700-1799 416.90 1.83
1800-1899 259.75 1.14
1900-1999 0.00 0.00
>2000 0.00 0.00

Lifetime: Time vs Engine Load Factor - 3516B Engine - Genset #1 (YAT00759)


Engine Load Factor( % ) hours %
<5 18.05 0.08
5-9 45.95 0.20
10-14 3.60 0.02
15-19 52.65 0.23
20-24 40.45 0.18
25-29 14.40 0.06
30-34 150.15 0.66
35-39 631.40 2.77
40-44 2302.95 10.10
45-49 4454.30 19.53
50-54 6068.90 26.61
55-59 4814.50 21.11
60-64 2598.15 11.39
65-69 645.10 2.83
70-74 300.65 1.32
75-79 213.95 0.94
80-84 231.05 1.01
85-89 172.80 0.76
90-94 46.65 0.20
95-99 1.10 0.00
>100 0.65 0.00

Lifetime: Time vs Right Exhaust Temperature - 3516B Engine - Genset #1 (YAT00759)


Right Exhaust Temperature( hours %
Deg F )
<842 5654.35 24.79
842-868 1714.80 7.52
869-895 1805.55 7.92
896-922 2142.35 9.39
923-949 2139.95 9.38
950-976 1957.00 8.58
977-1003 1814.75 7.96
1004-1030 1453.45 6.37
1031-1057 1307.25 5.73
1058-1084 1041.20 4.57
1085-1111 632.45 2.77
1112-1138 318.65 1.40
1139-1165 214.70 0.94
1166-1192 182.80 0.80
1193-1219 120.75 0.53
1220-1246 88.45 0.39
1247-1273 67.50 0.30
1274-1300 63.05 0.28
1301-1327 53.45 0.23
1328-1354 27.05 0.12
1355-1381 5.80 0.03
1382-1408 1.75 0.01
>1409 0.35 0.00

Lifetime: Time vs Left Exhaust Temperature - 3516B Engine - Genset #1 (YAT00759)


Left Exhaust Temperature( Deg hours %
F)
<842 2344.35 10.28
842-868 1312.45 5.75
869-895 1479.40 6.49
896-922 1627.90 7.14
923-949 1777.40 7.79
950-976 1886.30 8.27
977-1003 1963.40 8.61
1004-1030 1853.95 8.13
1031-1057 1757.05 7.70
1058-1084 1628.15 7.14
1085-1111 1519.00 6.66
1112-1138 1202.55 5.27
1139-1165 771.60 3.38
1166-1192 446.80 1.96
1193-1219 299.60 1.31
1220-1246 219.25 0.96
1247-1273 185.55 0.81
1274-1300 131.25 0.58
1301-1327 98.55 0.43
1328-1354 86.50 0.38
1355-1381 75.20 0.33
1382-1408 71.35 0.31
>1409 69.85 0.31

Monitoring System - 3516B Engine - Genset #1 (YAT00759)


Description State Trip Point Delay Time
Altitude (atmospheric
pressure)
Moderate Severity (2) On 12.2 psi 0 sec
Engine Overspeed
Least Severe (1) On 2124 rpm 0 sec
Most Severe (3) On 2124 rpm 0 sec
High Aftercooler
Coolant Temperature
Least Severe (1) On 216 Deg F 5 sec
Moderate Severity (2) On 225 Deg F 5 sec
Most Severe (3) On 225 Deg F 5 sec
High Air Filter
Restriction Pressure
Least Severe (1) On 28.1 " H2O 5 sec
Moderate Severity (2) On 28.1 " H2O 5 sec
High Boost Pressure
Least Severe (1) Off 58.0 psi 0 sec
Moderate Severity (2) Off 58.0 psi 0 sec
High Crankcase
Pressure
Least Severe (1) On 8.0 " H2O 3 sec
Moderate Severity (2) On 24.1 " H2O 10 sec
Most Severe (3) On 14.1 " H2O 3 sec
High Engine Coolant
Temperature
Least Severe (1) On 216 Deg F 5 sec
Moderate Severity (2) On 225 Deg F 30 sec
Most Severe (3) On 225 Deg F 5 sec
High Engine Oil Filter
Restriction Pressure
Least Severe (1) On 15 psi 5 sec
High Exhaust
Temperature
Least Severe (1) On 1342 Deg F 5 sec
Moderate Severity (2) On 1342 Deg F 5 sec
High Fuel Filter
Restriction Pressure
Least Severe (1) On 15 psi 5 sec
Low Aftercooler
Coolant Level
Least Severe (1) On None 30 sec
Most Severe (3) Off None 30 sec
Low Coolant Level
Least Severe (1) On None 30 sec
Most Severe (3) Off None 30 sec
Low Engine Coolant
Temperature
Least Severe (1) On 176 Deg F 5 sec
Low Engine Oil
Pressure
Least Severe (1) On None 4 sec
Most Severe (3) On None 9 sec
Low Fuel Pressure
Most Severe (3) On 32 psi 20 sec
Low System Voltage
Least Severe (1) On 20 Volts 10 sec

Injector Codes Calibration - 3516B Engine - Genset #1 (YAT00759)


Injector Code
Injector 1 2536
Injector 2 4119
Injector 3 3982
Injector 4 3967
Injector 5 1435
Injector 6 2425
Injector 7 2218
Injector 8 9907
Injector 9 1220
Injector 10 1347
Injector 11 5940
Injector 12 1124
Injector 13 2535
Injector 14 2557
Injector 15 5612
Injector 16 9905

You might also like