0% found this document useful (0 votes)
15 views8 pages

Annexure-3 Naphtha Laboratory Report HMEL

The document contains multiple laboratory test reports from Hindustan Petroleum Corporation Limited for the product 'Low Aromatic Naphtha'. Each report includes details such as sample source, testing dates, characteristics tested (like density, boiling points, and total sulfur), and results. The reports emphasize that the results apply only to the samples tested and cannot be reproduced or used in advertising without permission.

Uploaded by

neha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views8 pages

Annexure-3 Naphtha Laboratory Report HMEL

The document contains multiple laboratory test reports from Hindustan Petroleum Corporation Limited for the product 'Low Aromatic Naphtha'. Each report includes details such as sample source, testing dates, characteristics tested (like density, boiling points, and total sulfur), and results. The reports emphasize that the results apply only to the samples tested and cannot be reproduced or used in advertising without permission.

Uploaded by

neha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

HINDUSTAN PETROLEUM CORPORATION LIMITED

(A Government of India Enterprise)


QUALITY CONTROL LABORATORY
MUNDRA TERMINAL
OLD PORT ROAD, DISTRICT-KUTCH
MUNDRA - 370421, GUJARAT
LABORATORY TEST REPORT

Product 0901000 ( LOW AROMATIC NAPTHA ) Test Report Number 1546232400271

Loc/ Customer/ Supplier 41009097 ( HPCL-MITTAL ENERGY LTD, BATHINDA Sample Number 890000021353
Source of the Sample TK 01 A/R FOR MT SEYCHELLES PRELUDE Lab Sr. No FS/MIS/23-24/HMEL/35

Tank No. TK1 (TANK FOR BSVI HS) ULR Number TC-11456230000000271

Type of the Sample COMPOSITE Date of Sampling 02.10.2023 13:00:35

Number/Quantity of Sample 5*1 L Date of Receipt of Sample 02.10.2023

Batch No. LAN /OCEAN TANKER/HPC/HTMU/TK01/05 Date(s) of Sample Testing 02.10.2023 To 02.10.2023

Stock Represented 34,040.000 KL Date of Issue of the Report 02.10.2023 20:11:02

Test Required BATCH FORMATION TEST (TEST B) Sample Drawn By OPERATOR SANJAY

Sampling Plan/Method IS 1447 Wooden Box Seal


Seal
Reason for Testing A/R OCEAN TANKER MT SEYCHELLES PRELUDE No. Aluminium Box Seal

S.No Characteristics UOM Test Method Specifications Result


1 APPEARANCE - VISUAL CLEAR AND BRIGHT CLEAR AND BRIGHT
2 COLOUR (SAYBOLT) - IS 1448 P:14 TO REPORT 30
3 DENSITY AT 15°C kg/m³ IS 1448 P:16 TO REPORT 692.8
4 DENSITY AT 15°C, TOP kg/m³ IS 1448 P:16 TO REPORT 692.2
5 DENSITY AT 15°C, MIDDLE kg/m³ IS 1448 P:16 TO REPORT 692.6
6 DENSITY AT 15°C, BOTTOM kg/m³ IS 1448 P:16 TO REPORT 694.7
7 DIST : INITIAL BOILING POINT °C IS 1448 P:18 TO REPORT 37.0
8 DIST : 50 PERCENT RECOVERY V/V °C IS 1448 P:18 TO REPORT 78.9
9 DIST : FINAL BOILING POINT °C IS 1448 P:18 TO REPORT 173.7
10 TOTAL SULPHUR mg/kg ISO 20846 TO REPORT 126.0

Remarks : The Sample records the results as above. Density (kg/m3) at 15 degC: Upper- 692.4, Lower- 693.2

Tested By: Reviewed and Authorised By:


SEN RAKESH (31999220) SEN RAKESH (31999220)

Note:
1) The sample is drawn by client and results apply to the sample as received.
2) The test report shall not be reproduced except in full without prior written approval of the Lab In-charge.
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory.
4) Test results reported are valid for the sample tested, which was provided at the time of testing.
5) Entire quantity of sample expended during testing.
6) The details of sample submitted is provided by sender / customer. The authenticity / correctness of the submitted data is the responsibility of the sender/customer.
7) This is a system generated test report. Hence, it does not require signature.

REGISTERED OFFICE: 17, JAMSHEDJI TATA ROAD, MUMBAI 400020. CIN: L23201MH 1952GOI008858 Website: www.hindustanpetroleum.com
**** END OF REPORT ****
Page 1 of 1
HINDUSTAN PETROLEUM CORPORATION LIMITED
(A Government of India Enterprise)
QUALITY CONTROL LABORATORY
MUNDRA TERMINAL
OLD PORT ROAD, DISTRICT-KUTCH
MUNDRA - 370421, GUJARAT
LABORATORY TEST REPORT

Product 0901000 ( LOW AROMATIC NAPTHA ) Test Report Number 1546232400397

Loc/ Customer/ Supplier 1546 ( Mundra Terminal-MDPL ) Sample Number 890000037816


Source of the Sample TK 3 A/R MT SPARKLE Lab Sr. No FS/MIS/23-24/HMEL/49

Tank No. TK3 (Tank for HSD BS) ULR Number TC-11456230000000397

Type of the Sample COMPOSITE Date of Sampling 13.11.2023 00:10:43

Number/Quantity of Sample 1*5 L Date of Receipt of Sample 13.11.2023

Batch No. LAN/OCEAN TANKER/HPC/HTMU/TK03/04 Date(s) of Sample Testing 13.11.2023 To 13.11.2023

Stock Represented 34,071.000 KL Date of Issue of the Report 13.11.2023 21:09:41

Test Required BATCH FORMATION TEST (TEST B) Sample Drawn By PRAKASH

Sampling Plan/Method IS 1447 Wooden Box Seal


Seal
Reason for Testing A/R OCEAN TANKER MT SPARKLE No. Aluminium Box Seal

S.No Characteristics UOM Test Method Specifications Result


1 APPEARANCE - VISUAL CLEAR AND BRIGHT CLEAR AND BRIGHT
2 COLOUR (SAYBOLT) - IS 1448 P:14 TO REPORT 30
3 DENSITY AT 15°C kg/m³ IS 1448 P:16 TO REPORT 670.5
4 DENSITY AT 15°C, TOP kg/m³ IS 1448 P:16 TO REPORT 668.9
5 DENSITY AT 15°C, MIDDLE kg/m³ IS 1448 P:16 TO REPORT 670.4
6 DENSITY AT 15°C, BOTTOM kg/m³ IS 1448 P:16 TO REPORT 670.9
7 DIST : INITIAL BOILING POINT °C IS 1448 P:18 TO REPORT 39.5
8 DIST : 50 PERCENT RECOVERY V/V °C IS 1448 P:18 TO REPORT 62.7
9 DIST : FINAL BOILING POINT °C IS 1448 P:18 TO REPORT 137.2
10 TOTAL SULPHUR mg/kg ISO 20846 TO REPORT 29.4

Remarks : The Sample records the results as above. Density (kg/m3) at 15 degC: Upper- 669.1, Lower- 670.9

Tested By: Reviewed and Authorised By:


SEN RAKESH (31999220) SEN RAKESH (31999220)

Note:
1) The sample is drawn by client and results apply to the sample as received.
2) The test report shall not be reproduced except in full without prior written approval of the Lab In-charge.
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory.
4) Test results reported are valid for the sample tested, which was provided at the time of testing.
5) Entire quantity of sample expended during testing.
6) The details of sample submitted is provided by sender / customer. The authenticity / correctness of the submitted data is the responsibility of the sender/customer.
7) This is a system generated test report. Hence, it does not require signature.

REGISTERED OFFICE: 17, JAMSHEDJI TATA ROAD, MUMBAI 400020. CIN: L23201MH 1952GOI008858 Website: www.hindustanpetroleum.com
**** END OF REPORT ****
Page 1 of 1
HINDUSTAN PETROLEUM CORPORATION LIMITED
(A Government of India Enterprise)
QUALITY CONTROL LABORATORY
MUNDRA TERMINAL
OLD PORT ROAD, DISTRICT-KUTCH
MUNDRA - 370421, GUJARAT
LABORATORY TEST REPORT

Product 0901000 ( LOW AROMATIC NAPTHA ) Test Report Number 1546232400404

Loc/ Customer/ Supplier 41009097 ( HPCL-MITTAL ENERGY LTD, BATHINDA Sample Number 890000039986
Source of the Sample TK 1 A/R MT SPARKLE Lab Sr. No FS/MIS/23-24/HMEL/50

Tank No. TK1 (TANK FOR BSVI HS) ULR Number TC-11456230000000404

Type of the Sample COMPOSITE Date of Sampling 14.11.2023 16:00:34

Number/Quantity of Sample 5*1 L Date of Receipt of Sample 15.11.2023

Batch No. LAN/OCEAN TANKER/HPC/HTMU/TK01/08 Date(s) of Sample Testing 15.11.2023 To 15.11.2023

Stock Represented 33,631.000 KL Date of Issue of the Report 15.11.2023 14:32:17

Test Required BATCH FORMATION TEST (TEST B) Sample Drawn By PANKAJ JI

Sampling Plan/Method IS 1447 Wooden Box Seal


Seal
Reason for Testing A/R OCEAN TANKER MT SPARKLE No. Aluminium Box Seal

S.No Characteristics UOM Test Method Specifications Result


1 APPEARANCE - VISUAL CLEAR AND BRIGHT CLEAR AND BRIGHT
2 COLOUR (SAYBOLT) - IS 1448 P:14 TO REPORT 30
3 DENSITY AT 15°C kg/m³ IS 1448 P:16 TO REPORT 670.3
4 DENSITY AT 15°C, TOP kg/m³ IS 1448 P:16 TO REPORT 670.0
5 DENSITY AT 15°C, MIDDLE kg/m³ IS 1448 P:16 TO REPORT 670.2
6 DENSITY AT 15°C, BOTTOM kg/m³ IS 1448 P:16 TO REPORT 672.0
7 DIST : INITIAL BOILING POINT °C IS 1448 P:18 TO REPORT 40.4
8 DIST : 50 PERCENT RECOVERY V/V °C IS 1448 P:18 TO REPORT 64.7
9 DIST : FINAL BOILING POINT °C IS 1448 P:18 TO REPORT 145.7
10 TOTAL SULPHUR mg/kg ISO 20846 TO REPORT 3.1

Remarks : The Sample records the results as above. Density (kg/m3) at 15 degC: Upper- 670.0, Lower- 670.9

Tested By: Reviewed and Authorised By:


SEN RAKESH (31999220) SEN RAKESH (31999220)

Note:
1) The sample is drawn by client and results apply to the sample as received.
2) The test report shall not be reproduced except in full without prior written approval of the Lab In-charge.
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory.
4) Test results reported are valid for the sample tested, which was provided at the time of testing.
5) Entire quantity of sample expended during testing.
6) The details of sample submitted is provided by sender / customer. The authenticity / correctness of the submitted data is the responsibility of the sender/customer.
7) This is a system generated test report. Hence, it does not require signature.

REGISTERED OFFICE: 17, JAMSHEDJI TATA ROAD, MUMBAI 400020. CIN: L23201MH 1952GOI008858 Website: www.hindustanpetroleum.com
**** END OF REPORT ****
Page 1 of 1
HINDUSTAN PETROLEUM CORPORATION LIMITED
(A Government of India Enterprise)
QUALITY CONTROL LABORATORY
MUNDRA TERMINAL
OLD PORT ROAD, DISTRICT-KUTCH
MUNDRA - 370421, GUJARAT
LABORATORY TEST REPORT

Product 0901000 ( LOW AROMATIC NAPTHA ) Test Report Number 1546232400698

Loc/ Customer/ Supplier 41009097 ( HPCL-MITTAL ENERGY LTD, BATHINDA Sample Number 890000081120
Source of the Sample A/R MT HIGH FREEDO Lab Sr. No FS/MIS/23-24/HMEL/70

Tank No. TK3 (Tank for HSD BS) ULR Number

Type of the Sample COMPOSITE Date of Sampling 26.02.2024 10:30:00

Number/Quantity of Sample 1*1 L Date of Receipt of Sample 27.02.2024

Batch No. NA Date(s) of Sample Testing 27.02.2024 To 27.02.2024

Stock Represented 25,195.448 KL Date of Issue of the Report 27.02.2024 21:15:02

Test Required BATCH FORMATION TEST (TEST B) Sample Drawn By SOHAN/SURVEYOR

Sampling Plan/Method IS 1447 Wooden Box Seal


Seal
Reason for Testing A/R MT HIGH FREEDOM No. Aluminium Box Seal

S.No Characteristics UOM Test Method Specifications Result


1 APPEARANCE - VISUAL CLEAR AND BRIGHT CLEAR AND BRIGHT
2 COLOUR (SAYBOLT) - IS 1448 P:14 TO REPORT 30
3 DENSITY AT 15°C kg/m³ IS 1448 P:16 TO REPORT 690.3
4 DIST : INITIAL BOILING POINT °C IS 1448 P:18 TO REPORT 36.9
5 DIST : 50 PERCENT RECOVERY V/V °C IS 1448 P:18 TO REPORT 108.7
6 DIST : FINAL BOILING POINT °C IS 1448 P:18 TO REPORT 180.8
7 TOTAL SULPHUR mg/kg ASTM D5453 TO REPORT 1.8

Remarks : The Sampler Records the result as a above.

Tested By: Reviewed and Authorised By:


11546S1G SEN RAKESH (31999220)

Note:
1) The sample is drawn by client and results apply to the sample as received.
2) The test report shall not be reproduced except in full without prior written approval of the Lab In-charge.
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory.
4) Test results reported are valid for the sample tested, which was provided at the time of testing.
5) Entire quantity of sample expended during testing.
6) The details of sample submitted is provided by sender / customer. The authenticity / correctness of the submitted data is the responsibility of the sender/customer.
7) This is a system generated test report. Hence, it does not require signature.

REGISTERED OFFICE: 17, JAMSHEDJI TATA ROAD, MUMBAI 400020. CIN: L23201MH 1952GOI008858 Website: www.hindustanpetroleum.com
**** END OF REPORT ****
Page 1 of 1
Inspectorate International Limited
Certificate of Analysis Kanoo Maritime Center Building
Port of Fujairah
Fujairah, 4828, UAE
E: [email protected]
T: +971(9) 2281195

Operation Subject : Falcon Majestic Date Sampled : 04-Mar-2024


Product : Naphtha Date Received : 04-Mar-2024
Location : Fujairah, United Arab Emirates Analysis Date : 04-Mar-2024
Date Reported : 04-Mar-2024
Seal No. : None
Shore Tank Composite Before Loading
AEFUJ-24-00137-029 Specification
Test Method Unit Result Min - Max
Appearance Visual - Clear Clear Min
Saybolt Color ASTM D156-15 - +30 +20 Min
Density at 15°C ASTM D1298 kg/L 0.6888 0.65 - 0.75
Sulfur Content ASTM D5453 mg/kg 487 500 Max
Total Paraffins ASTM D6730 % (V/V) 80.512 70 Min
Olefins ASTM D6730 % (V/V) 0.477 2 Max
Naphthenes ASTM D6730 % (V/V) 12.659
Aromatics ASTM D6730 % (V/V) 6.296 19 Max
Distillation ASTM D86 - -
IBP ASTM D86 °C 29.9 25 Min
Final Boiling Point ASTM D86 °C 178.8 204 Max
RVP ASTM D5191 kPa 70.5 80 Max
Lead Content IP 224 µg/kg <3 50 Max
Sodium, Na ICPMS µg/kg 24 50 Max
Arsenic UOP 946 ppb (m/m) <5 5 Max
Mercury UOP 938 ppb (m/m) <0.3 10 Max
Chloride UOP 779 Mod. ppm (m/m) <0.3 5 Max
Total Oxygenates ASTM D7423 mg/kg 12.7 100 Max
Mercaptan Sulfur ASTM D3227 ppm (m/m) 58 100 Max
Carbon Disulfide ASTM D5623 mg/kg <0.1 3 Max
H2S in Liquid Phase UOP 163 mg/kg <1.0 5 Max

Remarks

AUTHORIZED SIGNATURE

Bryn Hawkings, Operations Manager

It is the responsibility of the end user to determine conformance appropriate to your end application, user should note the full provision of ASTM D3244, IP 367, ISO 4259 and UOP 999 whichever is
applicable. Sample information and thereafter validity of test results relates to the sample as received unless otherwise stated, results relate only to the sample tested. Lab uses latest version of test
methods unless otherwise stated in the report. Precision Statement of each test method will be applicable on the below results.
This document is issued by the Company under its General Terms & Conditions of Service accessible at https://commodities.bureauveritas.com/general-conditions-of-service . Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
executed to the fullest extent of the law. This Test Report cannot be reproduced, except in full, without prior written permission of the Company.

Page 1 of 1 AEFUJ-24-0013720240304071812
HINDUSTAN PETROLEUM CORPORATION LIMITED
(A Government of India Enterprise)
QUALITY CONTROL LABORATORY
MUNDRA TERMINAL
OLD PORT ROAD, DISTRICT-KUTCH
MUNDRA - 370421, GUJARAT
LABORATORY TEST REPORT

Product 0901000 ( LOW AROMATIC NAPTHA ) Test Report Number 1546232400758

Loc/ Customer/ Supplier 1546 ( Mundra Terminal-MDPL ) Sample Number 890000087081


Source of the Sample A/R TK1 - MT FALCON MAJESTIC Lab Sr. No FS/MIS/23-24/HMEL/72

Tank No. TK1 (TANK FOR BSVI HS) ULR Number

Type of the Sample COMPOSITE Date of Sampling 12.03.2024 11:20:54

Number/Quantity of Sample 1*1 L Date of Receipt of Sample 12.03.2024

Batch No. LAN/OCEAN TANKER/HPC/HTMU/TK01/10 Date(s) of Sample Testing 12.03.2024 To 12.03.2024

Stock Represented 33,789.000 KL Date of Issue of the Report 12.03.2024 18:10:44

Test Required BATCH FORMATION TEST (TEST B) Sample Drawn By HMEL SURVEYOR

Sampling Plan/Method IS 1447 Wooden Box Seal


Seal
Reason for Testing A/R OCEAN TANKER No. Aluminium Box Seal

S.No Characteristics UOM Test Method Specifications Result


1 APPEARANCE - VISUAL CLEAR AND BRIGHT CLEAR AND BRIGHT
2 COLOUR (SAYBOLT) - IS 1448 P:14 TO REPORT 30
3 DENSITY AT 15°C kg/m³ IS 1448 P:16 TO REPORT 690.6
4 DIST : INITIAL BOILING POINT °C IS 1448 P:18 TO REPORT 33.4
5 DIST : 50 PERCENT RECOVERY V/V °C IS 1448 P:18 TO REPORT 83.3
6 DIST : FINAL BOILING POINT °C IS 1448 P:18 TO REPORT 188.4
7 TOTAL SULPHUR mg/kg ASTM D5453 TO REPORT 436.0

Remarks : The Sampler Records the result as a above.

Tested By: Reviewed and Authorised By:


11546S1G 11546S1G

Note:
1) The sample is drawn by client and results apply to the sample as received.
2) The test report shall not be reproduced except in full without prior written approval of the Lab In-charge.
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory.
4) Test results reported are valid for the sample tested, which was provided at the time of testing.
5) Entire quantity of sample expended during testing.
6) The details of sample submitted is provided by sender / customer. The authenticity / correctness of the submitted data is the responsibility of the sender/customer.
7) This is a system generated test report. Hence, it does not require signature.

REGISTERED OFFICE: 17, JAMSHEDJI TATA ROAD, MUMBAI 400020. CIN: L23201MH 1952GOI008858 Website: www.hindustanpetroleum.com
**** END OF REPORT ****
Page 1 of 1
HINDUSTAN PETROLEUM CORPORATION LIMITED
(A Government of India Enterprise)
QUALITY CONTROL LABORATORY
MUNDRA TERMINAL
OLD PORT ROAD, DISTRICT-KUTCH
MUNDRA - 370421, GUJARAT
LABORATORY TEST REPORT

Product 0901000 ( LOW AROMATIC NAPTHA ) Test Report Number 1546242500063

Loc/ Customer/ Supplier 1546 ( Mundra Terminal-MDPL ) Sample Number 890000104856


Source of the Sample TK 1 A/R MT PALM HMEL VESSEL Lab Sr. No FS/MIS/24-25/HMEL/10

Tank No. TK1 (TANK FOR BSVI HS) ULR Number

Type of the Sample COMPOSITE Date of Sampling 19.04.2024 12:00:22

Number/Quantity of Sample 1*3 L Date of Receipt of Sample 20.04.2024

Batch No. LAN/OCEAN TANKER/HPC/HTMU/TK01/11 Date(s) of Sample Testing 20.04.2024 To 20.04.2024

Stock Represented 34,032.000 KL Date of Issue of the Report 20.04.2024 18:02:03

Test Required BATCH FORMATION TEST (TEST B) Sample Drawn By OPERATOR

Sampling Plan/Method IS 1447 Wooden Box Seal


Seal
Reason for Testing A/R OCEAN TANKER MT PALM(HMEL VESSEL) No. Aluminium Box Seal

S.No Characteristics UOM Test Method Specifications Result


1 APPEARANCE - VISUAL CLEAR AND BRIGHT CLEAR AND BRIGHT
2 COLOUR (SAYBOLT) - IS 1448 P:14 TO REPORT 29
3 DENSITY AT 15°C kg/m³ IS 1448 P:16 TO REPORT 704.4
4 DIST : INITIAL BOILING POINT °C IS 1448 P:18 TO REPORT 33.9
5 DIST : 50 PERCENT RECOVERY V/V °C IS 1448 P:18 TO REPORT 65.0
6 DIST : FINAL BOILING POINT °C IS 1448 P:18 TO REPORT 156.6
7 TOTAL SULPHUR mg/kg ASTM D5453 TO REPORT 94.0

Remarks : The Sampler Records the result as a above.

Tested By: Reviewed and Authorised By:


11546S1G 11546S1G

Note:
1) The sample is drawn by client and results apply to the sample as received.
2) The test report shall not be reproduced except in full without prior written approval of the Lab In-charge.
3) This test report shall not be used in any advertising media or as evidence in the Court of Law without prior written consent of Laboratory.
4) Test results reported are valid for the sample tested, which was provided at the time of testing.
5) Entire quantity of sample expended during testing.
6) The details of sample submitted is provided by sender / customer. The authenticity / correctness of the submitted data is the responsibility of the sender/customer.
7) This is a system generated test report. Hence, it does not require signature.

REGISTERED OFFICE: 17, JAMSHEDJI TATA ROAD, MUMBAI 400020. CIN: L23201MH 1952GOI008858 Website: www.hindustanpetroleum.com
**** END OF REPORT ****