Parker阀门和阀岛产品手册
Parker阀门和阀岛产品手册
Table of
Contents
1
2
Table of Contents
Directional
Version Actuation
Characteristics
Page
Dimensions Order Instructions
Control Valves
Overview
Manual Control 4 5 9 Series K9-G1/8
3/2 Way Valves Mechanical 4 6 9
Pedal 4 6 9
for panel mounting to Manual Control 4 7, 8 9
DIN 43696
3
3/2 Characteristics – Series K9
4
Rotary Lever – Type: K9 312..-1/8 Plunger Operated – Type: K9 323RF-1/8
∅
deep
2.7x8
Stroke min. 1.5 ∅
Stroke max. 3,0
∅
* = P when used as “normally closed“ * Self tapping screws CM 3x.. DIN 7500
** = P when used as “normally open“ to be used
** = P when used as “normally closed“
*** = P when used as “normally open“
∅
Actuation stroke
Actuation stroke 4,2
Dimensions in mm
5
Toggle Cam Operation – Type: K9 324RF-1/8 Pivoted Lever – Type: K9 329RF-1/8
∅
Actuation stroke
Actuation stroke
Actuation stroke
6
Basic Valve with adaptor for panel mounting Mounting holes for mounting diameters 22 and 30 mm
Type: K9 390RF-1/8
Mounting diameter ∅22 mm Mounting diameter ∅30 mm
Rotary Lever, indexed – Type: 12T-22, 12T-30 Rotary Lever with spring return – Type: 12T-RF-22, 12T-RF-30
Mounting diameter ∅22 mm Mounting diameter ∅30 mm Mounting diameter ∅22 mm Mounting diameter ∅30 mm
∅
∅
∅
∅
°
°
°
°
Dimensions in mm
7
Pushbutton – Type: 13T-RF-22, 13T-RF-30 Rotary Switch – Type: 17T-22, 17T-30
Mounting diameter ∅22 mm Mounting diameter ∅30 mm Mounting diameter ∅22 mm Mounting diameter ∅30 mm
∅ ∅
∅
∅
Mushroom Pushbutton – Type: 15T-RF-22, 15T-RF-30
°
∅
°
∅ ∅
Dimensions in mm
8
Order Instructions – 3/2 Way Poppet Valves, Series K9
Actuation Symbol Mounting Order Instructions Page
Ø (mm) Type Order No.
2
Rotary lever, 12 K9 312-1/8 PA 10269 5
indexed
1 3
2
Rotary lever, 12 10 K9 312RF-1/8 PA 10270 5
spring return
1 3
Rotary lever, 12 2
K9 312S-1/8 PA 10349 5
indexed
secured in both positions 1 3
2
Pushbutton 12 10 K9 314RF-1/8 PA 10271 5
1 3
2
Cam operation 12 10 K9 321RF-1/8 PA 10272 5
1 3
2
Toggle cam operation 12 10 K9 324RF-1/8 PA 10273 6
1 3
2
Plunger operated 12 10 K9 323RF-1/8 PA 10235 5
1 3
2
Cam operated 12 10 K9 325RF-1/8 PA 10274 6
free cam left
1 3
2
Cam operated 12 10 K9 326RF-1/8 PA 10275 6
free cam right
1 3
2
Pivoted lever 12 10 K9 329RF-1/8 PA 10276 6
1 3
2
Pedal 12 10 K9 331RF-1/8 PA 10277 6
1 3
2
Panel mounting valve with 10 K9 390RF-1/8 PA 10278 7
adaptor for interchangeable
actuation 1 3
9
10
Contents
Directional
Version Actuation
Characteristics
Page
Dimensions Order Instructions
Control Valves
Overview
Rotary lever 12 13 13 Series DRS-G1/8
4/3 Way Valves
Rotary switch 12 13 13
11
4/3 Way Characteristics – Series DRS
Characteristics Symbol Unit Description
Flat Slide General Features
Valves System Flat slide valve without automatic return to neutral
position
Mounting 2 Screws M4
Series DRS
Tube connection Thread
G1/8
Port size Port P, A, B: G1/8
Port R: M5
Actuation: Weight (mass) kg 0.500
– Rotary lever
– Rotary switch Installation In any position
Ambient temperature Tmin/max °C -10 to +55 Note:
range Please consult us for operating
temperatures below 0° C
12
Rotary Lever – Type: DRS 412 .-1/8 Rotary Switch – Type: DRS 417 .-1/8
∅
Angle of rotation
Swivelling range
Angle of ro-
tation
Rotary lever a b
A B
DRS 412 E-1/8 PA 10266
Middle position vented
P R
A B
Rotary lever a b
DRS 412G-1/8 PA 10268
Middle position closed
P R
A B
Rotary switch a b
DRS 417 B-1/8 PA 10264
Middle position pressurized
P R
A B
Rotary switch a b
DRS 417 E-1/8 PA 10263
Middle position vented
P R
A B
Rotary switch a b
DRS 417 G-1/8 PA 10265
Middle position closed
P R
Dimensions in mm
13
14
Contents
Compact
Version Actuation Page
Characteristics Dimensions Order Instructions
Valves
Overview
2 x 3/2 Way Valves pneumatic 16,17 18, 20 29 With threaded
electric 16,17 19, 21 29 ports
5/2 Way Valves pneumatic 16,17 22, 23 30 Series S10..-1/8
electric 16,17 24, 25 30 Series S10..-1/4
5/3 Way Valves pneumatic 16,17 22, 23, 26, 31 or
27
electric 16,17 24, 25, 28 31 with push-in
Valve Manifold 16,17 32-35 30
connections
Assemblies Series S10..-Q6
Valve Islands 16,17 37, 38 36 Series S10..-Q8
RPS-Manifolds 40 40
Accessories 41, 42 41, 42
Overview
Description Actuation Port Versions
G1/8 G1/4 Standard with with Middle Position Functions
Q6 Q8 biased external middle posi- middle posi- middle positi-
position pilot air tion closed tion vented on pressurized
2x3/2 Way Valves pneumatic ■ ■ ■ – – – – –
normally closed permanent signal (1
normally open electric ■ ■ ■ – ■ – – –
permanent signal (1
5/2 Way Valves pneumatic ■ ■ ■ – – – – –
permanent signal (2
pneumatic ■ ■ ■ ■ – – – –
impulse
electric ■ ■ ■ – ■ – – –
permanent signal (2
electric ■ ■ ■ ■ ■ – – –
impulse
5/3 Way Valves pneumatic ■ ■ ■ – – ■ ■ ■
permanent signal
electric ■ ■ ■ – ■ ■ ■ ■
permanent signal
(1
Air spring return
(2
Return by either mechanical spring or air spring (see Order Instructions, page 29-31)
Note:
S10 Series valves are normally supplied without connector
– please include in Order Code or order separately (see Order Instructions)
15
Characteristics – Series S10..-1/8, S10..-1/4, S10..-Q6, S10..-Q8 (Single Valves) and IM10 (Valve Islands)
Characteristics Symbol Unit Description
Version with threaded ports with push-in connections (version Q6, Q8)
Nominal flow
Series QN l/min 5/2 way version 650, 5/3 way version 550, 2x3/2 way version 400
– S10..-1/8, S10..-Q6
Series QN l/min 5/2 way version 950, 5/3 way version 850, 2x3/2 way version 850
– S10..-1/4, S10..-Q8
16
Characteristics Symbol Unit Description
Actuation
Pneumatic Direct
– actuation pressure range
– permanent signal version pst min./max. bar 2 – 8 (5/2 way version), 3 – 8 (5/3 and 2x3/2 way version)
– impulse version pst min./max. bar 1.5 – 8 (5/2 way version)
Electrical Electrically pilot actuated
single Valves S10
Voltage types Alternating current (50/60Hz) Direct current
Nominal voltage
– standard version Un V 230, 110, 48 ±10% 24, 12 ±10%
other voltages available on request
Power consumption, switching
– standard version VA (W) ca. 2.8 1.1
Power consumption, holding
– standard version VA (W) ca. 2 1.1
Duty cycle ED % 100
Electrical protection IP IP 65 to DIN 40050
(applise only to solenoid with plug)
Connection Connector to DIN EN 175301-803 form C (1
Electrical Electrically pilot actuated
valve islands IM10
Nominal voltage Un V 24, 12
Voltage types Direct current
Power consumption, switching VA (W) 1.1
Power consumption, holding VA (W) 1.1
Duty cycle ED % 100
Electrical protection IP IP 65 to DIN 40050
(Applise only to the electrically part in combination with sub-D connector,
IP 65)
Connection D-Sub connector 25pin
Switching indicator LED
Number of outputs max. 22, max. 18 (monostable)
(1 Solenoid also available with cable (length 1m) – see Order Instructions
17
2 x 3/2 Weight (mass) kg
Description Type Weight (mass)
Way Valves Pneumatic, by permanent signal S10 361R..-1/8 0.063 kg
Series S10 Electrical, by permanent signal S10 381R..-1/8 0.089 kg
Pneumatic, by permanent signal S10 361R..-Q6 0.070 kg
G1/8 Electrical, by permanent signal S10 381R..-Q6 0.097 kg
and
Push-In Connections 2 x 3/2 Way Valve, pneumatically actuated – threaded version
OD 6 mm Type: S10 361..-1/8
Actuation systems:
– Pneumatic
– Electrical pilot actuated
Versions:
– 2x normally closed
– 2x normally open
– 1x normally closed and
1x normally open
– With external pilot air
Accessories:
– Adapter plate for direct Ø2.6 – on rear side
mounting on M3 x 5 deep
HOERBIGER-ORIGA
profile-type cylinders
– Mounting bracket
(2
thread depth 5 mm
for tubing
(1
thread depth 7.5 mm
(2
thread depth 5 mm
18
2 x 3/2 Way Valve, electrically actuated (permanent signal) – threaded version
Type: S10 381R..-1/8
M3 x 5 deep
Manual override (only on version S)
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
2 x 3/2 Way Valve, electrically actuated (permanent signal) – version with push-in connections
Type: S10 381R..-Q6
M3 x 5 deep
Manual override for tubing (only on version S)
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
For valve manifolds see page 32-34, for RPS manifolds see page 38, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
19
2 x 3/2 Weight (mass) kg
Description Type Gew. (mass)
Way Valves Pneumatic, by permanent signal S10 361R..-1/4 0.094 kg
Series S10 Electrical, by permanent signal S10 381R..-1/4 0.123 kg
Pneumatic, by permanent signal S10 361R..-Q8 0.116 kg
G1/4 Electrical, by permanent signal S10 381R..-Q8 0.147 kg
and Push-In
Connections 2 x 3/2 Way Valve, pneumatically actuated – threaded version
OD 8 mm Type: S10 361..-1/4
(1
Actuation systems:
– Pneumatic
– Electrical pilot operated
Versions:
– 2x normally closed
– 2x normally open
– 1x normally closed and
1x normally open
– With external pilot air
Accessories:
– Adapter plate for direct
(2
page 41, 42 (1
thread depth 7.5 mm
(2
thread depth 5 mm
(1
for tubing Ø8 (2
(1
thread depth 7.5 mm
(2
thread depth 5 mm
20
2 x 3/2 Way Valve, electrically actuated (permanent signal) – threaded version
Type: S10 381R..-1/4
(1
– rear side M3 x 5 deep to
DIN EN 175301-803
form C
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
2 x 3/2 Way Valve, electrically actuated (permanent signal) – version with push-in connections
for tubing
Manual override
(1
thread depth 7.5 mm
(2
thread depth 5 mm
For RPS manifolds see page Page 39, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
21
5/2 and 5/3 Weight (mass) kg
Description Type Weight (mass)
Way Valves Pneumatic, by permanent signal S10 561R..-1/8 0.063 kg
Series S10 Pneumatic, by impulse S10 561(562)-1/8 0.063 kg
Electrical, by permanent signal S10 581R..-1/8 0.076 kg
G1/8 and Electrical, by impulse S10 581(582)-1/8 0.089 kg
Push-In Connections Pneumatic, by permanent signal S10 561R..-Q6 0.070 kg
OD 6 mm Pneumatic, by impulse S10 561(562)-Q6 0.070 kg
Electrical, by permanent signal S10 581R..-Q6 0.083 kg
Actuation systems: Electrical, by impulse S10 581(582)-Q6 0.097 kg
– Pneumatic
– Electrical, pilot operated
Versions:
– With biased position 5/2 and 5/3 Way Valve, pneumatically actuated – threaded version
– With external pilot air Type: S10 561..-1/8, S10 562..-1/8, S10 561RF.-1/8
Accessories:
– Adapter plate for direct
mounting on
Parker -ORIGA
profile-type cylinders
– Mounting bracket
For further information see
page 41, 42
(1
thread depth 7.5 mm
(2
thread depth 5 mm
22
5/2 and 5/3 Way Valve, pneumatically actuated – version with push-in connections
Type: S10 561..-Q6, S10 562..-Q6, S10 561RF.-Q6
Ø2.6 – rear side M3 x 5 deep
for tubing
(1
thread depth 7.5 mm
(2
thread depth 5 mm
For valve manifolds see page 32-34, for RPS manifolds see page 38, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
23
5/2 Way Valve, electrically actuated (permanent signal) – threaded version
Type: S10 581..-1/8
Ø2.6 – rear side M3 x 5 deep
Manual override (only on version S)
(2
thread depth 5 mm
5/2 Way Valve, electrically actuated (permanent signal) – version with push-in connections
Type: S10 581..-Q6
Ø2.6 – M3 x 5 deep
Manual override for tubing (only on version S)
(1
thread depth 7.5 mm
(2
thread depth 5 mm
For valve manifolds see page 32-34, for RPS manifolds see page 38, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
24
5/2 Way Valve, electrically actuated (impulse) – threaded version, Type: S10 581-1/8, S10 582-1/8
5/3 Way Valve, electrically actuated (permanent signal) – threaded version, Type: S10 581RF.-1/8
Manual override (only on version S)
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
5/2 Way Valve, electrically actuated (impulse) – version with push-in connections, Type: S10 581-Q6, S10 582-Q6
5/3 Way Valve, electrically actuated (permanent signal) – version with push-in connections, Type: S10 581RF.-Q6
M3 x 5 deep
Manual override for tubing (only on version S)
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
For valve manifolds see page 32, 34, for RPS manifolds see page 38, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
25
5/2 and 5/3 Weight (mass) kg
Description Type Weight (mass)
Way Valves Pneumatic, by permanent signal
Pneumatic, by impulse
S10 561R..-1/4
S10 561(562)-1/4
0.097 kg
0.097 kg
Versions:
– With biased position
– With external pilot air
Accessories:
– Adapter plate for direct
mounting on
Parker Origa
profile-type cylinders
– Mounting bracket
(2
(1
thread depth 7.5 mm
thread depth 5 mm
(2
5/2 and 5/3 Way Valve, pneumatically actuated, version with push-in connections
Type: S10 561..-Q8, S10 562..-Q8, S10 561RF.-Q8
(1
for tubing Ø8 (2
(1
thread depth 7.5 mm
(2
thread depth 5 mm
26
5/2 Way Valve, electrically actuated (permanent signal) – threaded version
Type: S10 581..-1/4
(1
– on rear side M3 x 5 deep to
DIN EN 175301-803
form C
(1
thread depth 7.5 mm
(2
thread depth 5 mm
5/2 Way Valve, electrically actuated (permanent signal) – version with push-in connections
Type: S10 581..-Q8
(1
Manual override
for tubing Ø8 (2 (only on version S)
(1
thread depth 7.5 mm
(2
thread depth 5 mm
For RPS manifolds see page 39, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
27
5/2 Way Valve, electrically actuated (impulse) – threaded version Type: S10 581-1/4, S10 582-1/4
5/3 Way Valve, electrically actuated (permanent signal) – threaded version Type: S10 581RF.-1/4
(1
– on rear side M3 x 5 deep to
DIN EN 175301-803
form C
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
5/2 Way Valve, electrically actuated (impulse) – version with Push-In Connections Type: S10 581-Q6, S10 582-Q8
5/3 Way Valve, electrically actuated (permanent signal) – version with Push-In Connections Type: S10 581RF.-Q8
for tubing
(1
thread depth 7.5 mm
(2
thread depth 5 mm
Manual override
For RPS manifolds see page 39, for mounting bracket see page 41,
for adapter plate see page 41
Dimensions in mm
28
Order Instructions – 2 x 3/2 Way Valves, Series S10..-1/8, S10..-1/4, S10..-Q6, S10..-Q8
Actuation System Symbol Connections Order Instructions Page
Thread Push-In Type Order No.
Pneumatic G1/8 – S10 361R2G-1/8 PA 10417 18
by permanent signal – ODØ 6mm S10 361R2G-Q6 PA 10447 18
G1/4 – S10 361R2G-1/4 PA 10537 22
– ODØ 8mm S10 361R2G-Q8 PA 10567 23
G1/8 – S10 361R2O-1/8 PA 10418 18
– ODØ 6mm S10 361R2O-Q6 PA 10448 18
G1/4 – S10 361R2O-1/4 PA 10538 22
– ODØ 8mm S10 361R2O-Q8 PA 10568 23
G1/8 – S10 361RGO-1/8 PA 10419 20
– ODØ 6mm S10 361RGO-Q6 PA 10449 18
G1/4 – S10 361RGO-1/4 PA 10539 22
– ODØ 8mm S10 361RGO-Q8 PA 10569 23
Electrical
G1/8 – S10 381R2G-1/8-33- PA 10404-33- 19
by permanent signal – ODØ 6mm S10 381R2G-Q6-33- PA 10434-33- 19
G1/4 – S10 381R2G-1/4-33- PA 10524-33- 21
– ODØ 8mm S10 381R2G-Q8-33- PA 10554-33- 21
G1/8 – S10 381R2O-1/8-33- PA 10406-33- 19
– ODØ 6mm S10 381R2O-Q6-33- PA 10436-33- 19
G1/4 – S10 381R2O-1/4-33- PA 10526-33- 21
– ODØ 6mm S10 381R2O-Q8-33- PA 10556-33- 21
G1/8 – S10 381RGO-1/8-33- PA 10408-33- 19
– ODØ 6mm S10 381RGO-Q6-33- PA 10438-33- 19
G1/4 – S10 381RGO-1/4-33- PA 10528-33- 21
– ODØ 8mm S10 381RGO-Q8-33- PA 10558-33- 21
Electrical
G1/8 – S10 381S-R2G-1/8-33- PA 10405-33- 19
by permanent signal – ODØ 6mm S10 381S-R2G-Q6-33- PA 10435-33- 19
with external pilot air G1/4 – S10 381S-R2G-1/4-33- PA 10525-33- 21
– ODØ 8mm S10 381S-R2G-Q8-33- PA 10555-33- 21
G1/8 – S10 381S-R2O-1/8-33- PA 10407-33- 19
– ODØ 6mm S10 381S-R2O-Q6-33- PA 10437-33- 19
G1/4 – S10 381S-R2O-1/4-33- PA 10527-33- 21
– ODØ 8mm S10 381S-R2O-Q8-33- PA 10557-33- 21
G1/8 – S10 381S-RGO-1/8-33- PA 10409-33- 19
– ODØ 6mm S10 381S-RGO-Q6-33- PA 10439-33- 19
G1/4 – S10 381S-RGO-1/4-33- PA 10529-33- 21
– ODØ 6mm S10 381S-RGO-Q8-33- PA 10559-33- 21
29
Order Instructions – 5/2 Way Valves, Series S10..-1/8, S10..-1/4, S10..-Q6, S10..-Q8
Actuation System Symbol Connections Order Instructions Page
Thread Push-In Type Order No.
Connections
Pneumatic
G1/8 – S10 561RF-1/8 PA 10410 22, 23
by permanent signal
– ODØ 6mm S10 561RF-Q6 PA 10440 22, 23
G1/4 – S10 561RF-1/4 PA 10530 26
– ODØ 8mm S10 561RF-Q8 PA 10560 26
G1/8 – S10 561R-1/8 PA 10411 22, 23
– ODØ 6mm S10 561R-Q6 PA 10441 22, 23
G1/4 – S10 561R-1/4 PA 10531 26
– ODØ 8mm S10 561R-Q8 PA 10561 26
Pneumatic by impulse
G1/8 – S10 561-1/8 PA 10412 22, 23
– ODØ 6mm S10 561-Q6 PA 10442 22, 23
G1/4 – S10 561-1/4 PA 10532 26
– ODØ 8mm S10 561-Q8 PA 10562 26
– with biased position G1/8 – S10 562-1/8 PA 10413 22, 23
– ODØ 6mm S10 562-Q6 PA 10443 22, 23
G1/4 – S10 562-1/4 PA 10533 26
– ODØ 8mm S10 562-Q4 PA 10563 26
Electrical 4 2
G1/8 – S10 581RF-1/8-33- PA 10390-33- 24
by permanent signal 14 12
– ODØ 6mm S10 581RF-Q6-33- PA 10420-33- 24
5 13
G1/4 – S10 581RF-1/4-33- PA 10510-33- 27
– ODØ 8mm S10 581RF-Q8-33- PA 10540-33- 27
G1/8 – S10 581R-1/8-33- PA 10392-33- 24
– ODØ 6mm S10 581R-Q6-33- PA 10422-33- 24
G1/4 – S10 581R-1/4-33- PA 10512-33- 27
– ODØ 8mm S10 581R-Q8-33- PA 10542-33- 27
Electrical
G1/8 – S10 581S-RF-1/8-33- PA 10391-33- 24
by permanent signal
– ODØ 6mm S10 581S-RF-Q6-33- PA 10421-33- 24
with external pilot air G1/4 – S10 581S-RF-1/4-33- PA 10511-33- 27
– ODØ 8mm S10 581S-RF-Q8-33- PA 10541-33- 27
G1/8 – S10 581S-R-1/8-33- PA 10393-33- 24
– ODØ 6mm S10 581S-R-Q6-33- PA 10423-33- 24
G1/4 – S10 581S-R-1/4-33- PA 10513-33- 27
– ODØ 8mm S10 581S-R-Q8-33- PA 10543-33- 27
Electrical by impulse 4 2
G1/8 – S10 581-1/8-33- PA 10394-33- 25
14 12
– ODØ 6mm S10 581-Q6-33- PA 10424-33- 25
G1/4 – S10 581-1/4-33- PA 10514-33- 27
513
– ODØ 8mm S10 581-Q8-33- PA 10544-33- 27
– with biased position G1/8 – S10 582-1/8-33- PA 10396-33- 25
– ODØ 6mm S10 582-Q6-33- PA 10426-33- 25
G1/4 – S10 582-1/4-33- PA 10516-33- 27
– ODØ 8mm S10 582-Q8-33- PA 10546-33- 27
Electrical by impulse
G1/8 – S10 581S-1/8-33- PA 10395-33- 25
with external pilot air
– ODØ 6mm S10 581S-Q6-33- PA 10425-33- 25
G1/4 – S10 581S-1/4-33- PA 10515-33- 27
– ODØ 8mm S10 581S-Q8-33- PA 10545-33- 27
– with biased position G1/8 – S10 582S-1/8-33- PA 10397-33- 25
– ODØ 6mm S10 582S-Q6-33- PA 10427-33- 25
G1/4 – S10 582S-1/4-33- PA 10517-33- 27
– ODØ 8mm S10 582S-Q8-33- PA 10547-33- 27
30
Order Instructions – 5/3 Way Valves, Series S10..-1/8, S10..-1/4, S10..-Q6, S10..-Q8
Actuation System Symbol Connections Order Instructions Page
Thread Push-In Type Order No.
Pneumatic
G1/8 – S10 561RFG-1/8 PA 10414 23
permanent signal – ODØ 6mm S10 561RFG-Q6 PA 10444 23
G1/4 – S10 561RFG-1/4 PA 10534 26
– ODØ 8mm S10 561RFG-Q8 PA 10564 26
G1/8 – S10 561RFE-1/8 PA 10415 23
– ODØ 6mm S10 561RFE-Q6 PA 10445 23
G1/4 – S10 561RFE-1/4 PA 10535 26
– ODØ 8mm S10 561RFE-Q8 PA 10565 26
G1/8 – S10 561RFB-1/8 PA 10416 23
– ODØ 6mm S10 561RFB-Q6 PA 10446 23
G1/4 – S10 561RFB-1/4 PA 10536 26
– ODØ 8mm S10 561RFB-Q8 PA 10566 26
Electrical
G1/8 – S10 581RFG-1/8-33- PA 10398-33- 25
permanent signal – ODØ 6mm S10 581RFG-Q6-33- PA 10428-33- 25
G1/4 – S10 581RFG-1/4-33- PA 10518-33- 28
– ODØ 8mm S10 581RFG-Q8-33- PA 10548-33- 28
G1/8 – S10 581RFE-1/8-33- PA 10400-33- 25
– ODØ 6mm S10 581RFE-Q6-33- PA 10430-33- 25
G1/4 – S10 581RFE-1/4-33- PA 10520-33- 28
– ODØ 8mm S10 581RFE-Q8-33- PA 10550-33- 28
G1/8 – S10 581RFB-1/8-33- PA 10402-33- 25
– ODØ 6mm S10 581RFB-Q6-33- PA 10432-33- 25
G1/4 – S10 581RFB-1/4-33- PA 10522-33- 28
– ODØ 8mm S10 581RFB-Q8-33- PA 10552-33- 28
Electrical G1/8 – S10 581S-RFG-1/8-33- PA 10399-33- 25
permanent signal
– ODØ 6mm S10 581S-RFG-Q6-33- PA 10429-33- 25
with external pilot air G1/4 – S10 581S-RFG-1/4-33- PA 10519-33- 28
– ODØ 8mm S10 581S-RFG-Q8-33- PA 10549-33- 28
G1/8 – S10 581S-RFE-1/8-33- PA 10401-33- 25
– ODØ 6mm S10 581S-RFE-Q6-33- PA 10431-33- 25
G1/4 – S10 581S-RFE-1/4-33- PA 10521-33- 28
– ODØ 8mm S10 581S-RFE-Q8-33- PA 10551-33- 28
G1/8 – S10 581S-RFB-1/8-33- PA 10403-33- 25
– ODØ 6mm S10 581S-RFB-Q6-33- PA 10433-33- 25
G1/4 – S10 581S-RFB-1/4-33- PA 10523-33- 28
– ODØ 8mm S10 581S-RFB-Q8-33- PA 10553-33- 28
31
Valve Manifold Valve Manifold assembly, fully assembled – threaded version, Type: S10-1/8-..
Assemblies
Series S10
G1/8
fully assembled
Actuation systems:
– Pneumatic
– Electrical pilot actuated
Drawing shows:
6-fold valve manifold S10-1/8-06, 24VDC
Order No. PA10385-06-0233-00
Valve positions: JJMM33
For single valves see page 18-28, for order instructions see page 36
Dimensions in mm
32
Valve Manifold assembly, fully assembled – version with Push-In Connections, Type: S10-Q6-..
Valve Manifold
Assembly
Series S10
Push-In Connections
OD 6 mm
fully assembled
Actuation systems:
– Pneumatic
– Electrical pilot actuated
Drawing shows:
6-fold valve manifold S10-Q6-06, 24VDC
Order No. PA10386-06-0233-00
Valve positions: JJMM33
For single valves see page 18-28, for order instructions see page 36
Dimensions in mm
33
Order Instructions – Valve Manifold Assemblies
Order No. Valve positions
+
Solenoid version
Connector
Flow divider at
valve position
Number of
Valve positions 1-16
voltage
valves
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PA – – 33–
02 04 06 08 10 12 14 16
Version
PA 10385 Valves with
threaded
ports G1/8
Series:
S10-1/8
PA 10386 Valves with Only even numbers of Flow divider
push-in ports valves are possible! (for dualpressure operating)
OD 6 none (standard)
Series: Please enter the codes for the
valve types required. .. at valve position
S10-Q6
Number of Valves
02 1 – 2 valves
04 3 – 4 valves
06 5 – 6 valves
08 7 – 8 valves Order Codes Order Codes
10 9 – 10 valves for Valves and Cover Plates for Valves and Cover Plates
12 11 – 12 valves Code Description Page Code Description Page
14 13 – 14 valves A Cover plate for unused valve position 41 Electrically actuated
16 15 – 16 valves P Intermediate air supply adapter G1/8 41 K 2x 3/2 Way Valve NC, air spring return 19, 21
Pneumatically actuated N 2x 3/2 Way Valve NO, air spring return 19, 21
Solenoid version/ 8 2x 3/2 Way Valve NC, air spring return 18, 22 H 2x 3/2 Way Valve NC, NO, air spring return 19, 21
voltage 9 2x 3/2 Way Valve NO, air spring return 18, 22 M 5/2 Way Valve, spring return 24, 27
– for connector 0 2x 3/2 Way Valve NC, NO, air spring return 18, 22 L 5/2 Way Valve, air spring return 24, 27
00 without solenoid 1 5/2 Way Valve, spring return 22, 23, J 5/2 Way Valve, impulse 24, 27
01 12 V DC 26, 27 D 5/2 Way Valve, impulse, with biased position 24, 27
02 24 V DC 2 5/2 Way Valve, air spring return 22, 23, G 5/3 Way Valve, middle position closed, 25, 28
04 48 V DC 26, 27 spring return to middle position
07 110 V DC 3 5/2 Way Valve, impulse 22, 23, E 5/3 Way Valve, middle position exhausted, 25, 28
50 12 V AC 26, 27 spring return to middle position
51 24 V AC 4 5/2 Way Valve, impulse, with biased position 22, 23, B 5/3 Way Valve, middle position pressurized, 25, 28
55 48 V AC 26, 27 spring return to middle position
57 110 V AC 5 5/3 Way Valve, middle position closed, 22, 23,
61 230 V AC spring return to middle position 26, 27
– with cable (length 1m) 7 5/3 Way Valve, middle position exhausted, 22, 23, Order Codes
41 12 V DC spring return to middle position 26, 27 for Valves and Cover Plates
42 24 V DC 6 5/3 Way Valve, middle position pressurized, 22, 23, Code Description Page
71 12 V AC spring return to middle position 26, 27 Electrically actuated, with external pilot air
72 24 V AC X 2x 3/2 Way Valve NC, air spring return 19, 21
Other solenoid versions Y 2x 3/2 Way Valve NO, air spring return 19, 21
(voltages) available on request Z 2x 3/2 Way Valve NC, NO, air spring return 19, 21
F 5/2 Way Valve, spring return 24, 27
Connector R 5/2 Way Valve, air spring return 24, 27
Version S 5/2 Way Valve, impulse 24, 27
T 5/2 Way Valve, impulse, with biased position 24, 27
00 without connector U 5/3 Way Valve, middle position closed, 25, 28
(standard version) spring return to middle position
88 standard connector W 5/3 Way Valve, middle position exhausted, 25, 28
15 mm wide spring return to middle position
89 230 V AC with LED and V 5/3 Way Valve, middle position pressurized, 25, 28
protective circuit spring return to middle position
92 24 V DC with LED and
protective circuit
34
Valve Islands, fully assembled – threaded version, Type: IM10-1/8-..
Valve Islands
Series IM10
D-Sub multipole connector 25pole
G1/8
fully assembled
Actuation systems:
Version:
Multipole version with
D-Sub multipole connector
25pole.
Valve positions:
– Combination mono-/
bistable
outputs
max. 22
max. 18 (monostable)
On request:
Expandable with external
field bus components
Drawing shows: (Profi Bus DP, Inter Bus S,
6fold valve manifold IM10-1/8-06, 24VDC CAN Device net, AS-Interface
Order No. PA10490-06-22
Valve positions: JJMMMC
For single valves see page 18-28, for order instructions see page 39
Dimensions in mm
35
Valve Islands Valve Islands, fully assembled – with Push-In Connections, Type: IM10-Q6-..
Series IM10
Push-In Connections
OD 6 mm
fully assembled
Actuation systems:
– Electrical pilot actuated
Version:
Multipole version with
D-Sub multipole connector
25pole.
Valve positions:
– Combination mono-/
bistabil
Outputs
max. 22
max. 18 (monostable)
On request:
Expandable with external
field bus components Drawing shows:
(Profi Bus DP, Inter Bus S, 6fold Valve Islands IM10-Q6-06, 24VDC
CAN Device net, AS-Interface) Order No. PA10491-06-22
Valve positions: JJMMMC
For single valves see page 18-28, for order instructions see page 36
Dimensions in mm
36
Order Instructions – Valve Islands
Order No. Valve positions
Solenoid version
Flow divider to
Number of
Valve positions 1-16
voltage
valves
valve
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
PA – –
02 04 06 08 10 12 14 16 18
Version
PA 10490 Valve Islands
with threaded
ports G1/8 Even and uneven numbers of Flow divider
Series: valves are possible! (for dualpressure operating)
IM10-1/8 without (standard)
Please enter the codes for the
PA 10491 Valve Islands valve types required. .. at valve position
with push-in
connections
OD 6, Series:
IM10-Q6
Order Codes
for Valves and Cover Plates
Valves Code Description Page
02 2 valves A Cover plate for unused valve position 41
03 3 valves * C Cover plate (monostable)* 41
04 4 valves O Cover plate (bistabil)* 41
05 5 valves P Intermediate air supply adapter G1/8 41
* including electrical socket
18 18 Valves
* uneven number of valve Order Codes
positions on request for Valves and Cover Plates
Code Description Page
Electrically actuated
Solenoid version/ K 2x 3/2 Way Valve NC, air spring return 19
voltage N 2x 3/2 Way Valve NO, air spring return 19
21 12 V DC H 2x 3/2 Way Valve NC, NO, air spring return 19
22 24 V DC M 5/2 Way Valve, spring return 24
L 5/2 Way Valve, air spring return 24
J 5/2 Way Valve, impulse 24
D 5/2 Way Valve, impulse, with biased position 25
G 5/3 Way Valve, middle position closed, 25
spring return to middle position
E 5/3 Way Valve, middle position exhausted, 25
spring return to middle position
B 5/3 Way Valve, middle position pressurized, 25
spring return to middle position
Order Codes
for Valves and Cover Plates
Code Description Page
Electrically actuated, with external pilot air
X 2x 3/2 Way Valve NC, air spring return 19
Y 2x 3/2 Way Valve NO, air spring return 19
Z 2x 3/2 Way Valve NC, NO, air spring return 19
F 5/2 Way Valve, spring return 24
R 5/2 Way Valve, air spring return 24
S 5/2 Way Valve, impulse 24
T 5/2 Way Valve, impulse, with biased position 25
U 5/3 Way Valve, middle position closed, 25
spring return to middle position
W 5/3 Way Valve, middle position exhausted, 25
spring return to middle position
V 5/3 Way Valve, middle position pressurized, 25
spring return to middle position
37
RPS-Manifolds Dimension Table (mm) – Type: RPSL-S10-1/8-..
for Directional Valves
– Series S10-1/8
– Series S10-Q6
RPS manifolds reduce and
simplify the tubing layout.
They provide a space-saving,
clear and simple, compact
solution.
RPS manifolds have a com-
mon compressed air supply
port (P) and common exhaust
ports (R, S).
From 2 to 16 valves can be
mounted on them.
(Other sizes available on re-
quest)
Materials:
RPS manifold Drawing shows: 4fold valve manifold
– aluminium
Screws Dimension Table (mm)
– galvanized steel Type Number of valves Dimension
Gasket
– oil-resistant rubber A B
RPSL-S10-1/8-02 02 52 42
RPSL-S10-1/8-04 04 84 74
RPSL-S10-1/8-06 06 116 106
RPSL-S10-1/8-08 08 148 138
RPSL-S10-1/8-10 10 180 170
RPSL-S10-1/8-12 12 212 202
RPSL-S10-1/8-14 14 244 234
RPSL-S10-1/8-16 16 276 266
For single valves see page 18-28, for order instructions see page 36
Dimensions in mm
38
Dimension Table (mm) – Type: RPSL-S10-1/4-..
RPS Manifolds
for Directional Valves
– Series S10-1/4
– Series S10-Q8
RPS manifolds reduce and
simplify the tubing layout.
They provide a space-saving,
clear and simple, compact
solution.
RPS manifolds have a com-
mon compressed air supply
port (P) and common exhaust
ports (R, S).
From 2 to 16 valves can be
mounted on them.
(Other sizes available on re-
quest)
Materials:
Drawing shows: 3fold manifold RPS manifold
– aluminium
Maßtabelle (mm) Screws
Type Number Dimension – galvanized steel
of valves Gasket
A B – oil-resistant rubber
RPSL-S10-1/4-02 02 59 49
RPSL-S10-1/4-04 04 97 87
RPSL-S10-1/4-06 06 135 125
RPSL-S10-1/4-08 08 173 163
RPSL-S10-1/4-10 10 211 201
RPSL-S10-1/4-12 12 249 239
RPSL-S10-1/4-14 14 287 277
RPSL-S10-1/4-16 16 325 315
Dimensions in mm
39
Accessories Flow Divider Cover Plate
for unused Valve
Intermediate
Air Supply Adapter
for Valve Manifold Positions
Assemblies
Clamp Mounting for Order Instructions – Clamp Mounting for S10-1/8 (Q6)
DIN Rail Clamp Mounting Order No.
35 mm Number of valves for valve manifolds for valve islands
Type: S10-1/8 Type: IM10-1/8
2 PD47393-0002 PD47949-0002
4 PD47393-0004 PD47949-0004
6 PD47393-0006 PD47949-0006
8 PD47393-0008 PD47949-0008
10 PD47393-0010 PD47949-0010
11 – 18 on request PD48270
Versions:
– for Valve Manifolds S10
– for Valve Islands IM10 Order Instructions – Clamp Mounting for S10-1/4 (Q8)
Clamp Mounting Order No.
Material: Aluminium valves for RPS-manifold
Type: RPSL-S10-1/4-..
The delivery includes:
1 clamp mounting 2 PD49423-0002
4 screws 4 PD49423-0004
6 PD49423-0006
8 PD49423-0008
10 PD49423-0010
12-16 on request
Cable with
D-Sub multipole Order Instructions – Cable
connector 25pole Cable length Electrical protection Order No.
2m IP40 KL3355
5m IP40 KL3356
5m IP65 KL3357
Dimensions in mm
40
Dimension Table – Mounting Bracket for Single Valves Mounting Bracket for Accessories
Mounting Screws Single Valves
DIN ISO 4762 - M3 x 6 Series S10 for Single Valves
Material: Steel, passivated
Dimension Table – Adapter Plate for Single Valves S10-1/8 (Q6) Adapter Plate
for Single Valves
Series S10-1/8 (Q6)
Series S10-1/4 (Q8)
Order No.
– S10-1/8 (Q6): PD47420
– S10-1/4 (Q8): PD49325
Dimensions in mm
41
Accessories Connectors
for Series S10
Dimension Table – Connector
– Standard version
– version with LED
Gasket
Material: Plastic
Dimensions in mm
42
Contents Directional
Version Actuation Page
System Characteristics Dimension Table Order Control Valves
Instructions
Overview
Series
3/2 Way Valves Manual Control 44-47 48-55 70-72
Series S9-G1/8, G1/4, pneumatic S9-G1/8 to G1/2
G1/2 electric
43
3/2, 5/2 Series S9 – G1/8 to G1/2
Characteristics Symbol Unit Series S9
and 5/3 G1/8
44
Series S9 Series S9
G1/4 G1/2
Manual control pneumatic electrical Manual control pneumatic electrical
6 6
0–10 – – 0–10 – –
– 0–10 2–10 – 0–10 2.2–10
– 0–10 2–10 – 0–10 2.2–10
– – 0–10 – – 0–10
1300(7 3500(8
Direct Direct
6.5 9.4
10 (2 15 (2
15 (3 40 (3
– –
Direct Direct
Direct current
45
3/2, 5/2 Series S9 – G1/8 to G1/2
Characteristics Symbol Unit Series S9
and 5/3 G1/8
Way Valves for Actuation
General Features
Manual Control pneumatic electrical
46
Series S9 Series S9
G1/4 G1/2
Manual Control pneumatic electrical Manual Control pneumatic electrical
Solids: Class 7 particle size <40 µm for gas Water content: pressure dew point + 3°C,
Class 4, but at least 5°C below minimum operating temperature
6 6
0–8 – – 0–8 – –
– 0–8 2–8 – 0–8 2.2–8
– 0–8 1.5–8(4 – 0–8 1.5–8(4
– – 0–8 – – 0–8
1300(7 3500(8
Direct Direct
6.5 9.4
10 (2 15 (2
15 (3 40 (3
– –
Direct Direct
47
3/2 Way Valves Weight (mass) kg
Description Type Weight (mass) kg
Series S9 Hand lever indexed S9 311-1/8 0.162
– with spring return S9 311RF-1/8 0.162
G1/8 Pneumatic, by permanent signal S9 361RF-1/8 0.137
Pneumatic, by impulse S9 361-1/8 0.147
Actuation:
– Hand lever Electrical, by permanent signal S9 381(S)RF-1/8 0.247
– Pneumatic Electrical, by impulse S9 381(S)-1/8 0.382
– Electrical pilot operated
– Electrical pilot operated
with external pilot air
– Panel mounting actuators Weight (mass) kg and action forces for valves with panel mounting actuators
for mounting diameter to Description Type Actuation force (N, Nm) Weight (mass) kg
DIN 43696
Rotary lever S9 312T-1/8 0.3 0.137
Versions: S9 312T-RF-1/8 0.3 0.137
– Normally closed
– Normally open Pushbutton S9 313T-RF-1/8 8.0 0.137
– With external pilot air Mushroom pushbutton S9 315T-RF-1/8 8.0 0.137
– Version to ATEX Standard
Locking switch S9 316T-1/8 9.0 0.202
Note: Rotary switch S9 317T-1/8 0.3 0.127
The “normally open“ valve S9
381S-RF-1/8 cannot be used Mushroom pushbutton S9 318T-1/8 10.0 0.137
on a P-supply manifold. emergency-0ff
94
29
20 7
11,5
19°
31,5
41
50
12
77
3
2
37
18
1
G1/8
10
5,5 22
5
40
For order instructions see page 70-72, characteristics see page 44-47
and for RPS manifolds see page 93-100, Valve Islands see page 87-92
Dimensions in mm
48
Pneumatically actuated – Type: S9 361-1/8, S9 361RF-1/8
only for type
S9361-1/8
Electrically actuated – Type: S9 381(S)-1/8, S9 381(S)RF-1/8 Solenoid for use in EX areas – Dimensions
10,5
*
M5
**
24,5
ca. 122
G1/8
33,5
42,5
24
110
12 (10)
pst X = 15,5 mm
ca. 190
3(1)
69,5
5,6
3,2
36
2
For more information on valves to ATEX standards
37
18
5
1(3)
G1/8
pst
10 (12)
16,6 **
15,5
* 5,5
56
15,5
only for type
40
S9 381 -1/8
S9 381S-1/8 63
* Manual override
** Operating pressure supply pst only for type S9 381S
*** Solenoid width = 30 mm on low wattage coil version
For order instructions see page 70-72, characteristics see page 44-47
P-Manifolds and for RPS manifolds see page 93-100, Valve Islands see page 87-92
Dimensions in mm
49
Basic valve for panel mounting actuatos – Type: S9 390RF-1/8 Mounting diameter
28
38
47
12
76,5
74
37
2
18
1
10 G1/8
22 5,5
5
40
Rotary lever, indexed – Type: 12T-22, 12T-30, Pushbutton – Type: 13T-RF-22, 13T-RF-30
Mounting diameter Ø22 mm Mounting diameter Ø30 mm Mounting diameter Ø22 mm Mounting diameter Ø30 mm
∅
∅ ∅
°
For order instructions see page 70-72, characteristics see page 44-47
Dimensions in mm
50
Mushroom pushbutton – Type: 15T-RF-22, 15T-RF-30 Locking switch – Type: 16T-22, 16T-30
Mounting diameter Ø22 mm Mounting diameter Ø30 mm Mounting diameter Ø22 mm Mounting diameter Ø30 mm
Rotary lever with spring return – Type: 12T-RF-22, 12T-RF-30
Mounting diameter Ø22 mm Mounting diameter Ø30 mm Mushroom pushbutton emergency-0ff – Type: 18T-22, 18T-30
°
°
°
°
51
3/2 Way Valves Weight (mass) kg
Description Type Weight (mass)
Series S9 Hand lever, indexed S9 311-1/4 0.370
– with spring return S9 311RF-1/4 0.370
G1/4 Safety hand lever S9 311S-1/4 0.370
Rotary lever, indexed S9 312-1/4 0.370
Actuation systems:
– Hand lever – with spring return S9 312RF-1/4 0.370
– Pneumatic Pneumatic, by permanent signal S9 361RF-1/4 0.370
– Electrical pilot operated
– Electrical pilot operated with Pneumatic, by impulse S9 361-1/4 0.430
external pilot air – with biased position S9 362-1/4 0.430
Versions: Electrical, by permanent signal S9 381(S) RF-1/4 0.500
– Normally closed Electrical, by impulse S9 381(S)-1/4 0.600
– Normally open
– with biased position S9 382(S)-1/4 0.600
– With external pilot air
– With biased position
– Version to ATEX Standard
Hand lever actuated – Type: S9 311-1/4, S9 311RF-1/4
120
44
25 12
18°
17
42,5
55
66
12
98
3
G1/4
2
47
22
10
6,5 32
52
120
44
25 12
18°
17
42,5
55
66
12
98
3
G1/4
2
47
22
10
6,5 32
52
52
Rotary lever actuated – Type: S9 312-1/4, S9 312RF-1/4 Electrically actuated
– Type: S9 381(S)-1/4, S9 382(S)-1/4, S9 381(S)RF-1/4
79,5 32
33° 33° 44 22 ***
25 12
17
42,5
55
*
66
12
M5
65
98
10
3
G 1/8
28,5
30
G1/4
41
ca. 137
2
ca. 209
47
22
12 (10) 25
126
52
1 pst
3(1)
84
5,5
10 2 **
44
22
47
o 7,5
o 4,2
1(3)
G 1/4
6,5 32
11
6 pst
52 10 (12)
4,5
20
**
6,5
* only for type
Pneumatically actuated
62
S9 381-1/4
6 S9 381S-1/4
– Type: S9 361-1/4, S9 362-1/4, S9 361RF-1/4 S9 382-1/4
S9 382S-1/4
15,5
25
52
63
12,5
G1/8
22,5
21
33,5
44,5
12
* Manual override
5,5
3
** Operating pressure supply pst only for type S9 381S
76,5
2
22
44
o 7,5
o 4,2
G1/4
10
Note:
12,5
only for type The “normally open“ valve S9 381S-RF-1/4 cannot be used
6,5 4,5 32
S9 361-1/4 on a P-supply manifold.
6 S9 362-1/4
52
X = 15.5 mm
For order instructions see page 70-72, characteristics see page 44-47
Dimensions in mm
53
3/2 Way Valves Weight (mass) kg
Description Type Weight (mass)
Series S9 Hand lever, indexed S9 311-1/2 0.900
– with spring return S9 311RF-1/2 0.900
G1/2 Safety hand lever S9 311S-1/2 0.900
Rotary lever, indexed S9 312-1/2 0.950
Actuation systems:
– Hand lever –with spring return S9 312RF-1/2 0.950
– Pneumatic Pneumatic, by permanent signal S9 361RF-1/2 0.700
– Electrical pilot operated
– Electrical pilot operated with Pneumatic, by impulse S9 361-1/2 0.650
external pilot air – with biased position S9 362-1/2 0.650
54
Rotary lever actuated – Type: S9 312-1/2, S9 312RF-1/2 Electrically actuated
Type: S9 381(S)-1/2, S9 382(S)-1/2, S9 381(S)RF-1/2
6 deep
only for type
S9 581(S)-1/2
S9 582(S)-1/2
Note:
6 deep
X = 21 mm
For order instructions see page 70-72, characteristics see page 44-47
Dimensions in mm
55
5/2 Way Valves Weight (mass) kg
Description Type Weight (mass)
Series S9 Hand lever, indexed S9 511-1/8 0.195
– with spring return S9 511RF-1/8 0.195
G1/8 Safety hand lever S9 511S-1/8 0.195
Pneumatic, by permanent signal S9 561RF-1/8 0.160
Actuation systems:
– Hand lever Pneumatic, by impulse S9 561-1/8 0.170
– Safety hand lever Electrical, by permanent signal S9 581(S)RF-1/8 0.280
– Pneumatic
– Electrical pilot operated Electrical, by impulse S9 581(S)-1/8 0.415
– Electrical pilot operated – with biased position S9 582-1/8 0.415
with external pilot air
– Panel mounting actuators
to DIN 43696 Weight (mass) and actuating forces for valves with panel mounting
Description Type Actuating force Weight (mass)
Versions: (N, Nm) (kg)
– With external pilot air
Rotary lever S9 512T-1/8 0.3 0.160
– With biased position
– Version to ATEX Standard S9 512T-RF-1/8 0.3 0.160
Pushbutton S9 513T-RF-1/8 8.0 0.150
Mushroom pushbutton S9 515T-RF-1/8 8.0 0.160
Locking switch S9 516T-1/8 9.0 0.225
Rotary switch S9 517T-1/8 0.3 0.150
Mushroom pushbutton S9 518T-1/8 10.0 0.160
emergency-0ff
°
56
Safety hand lever actuated – Type: S9 511S-1/8 Electrically actuated
Type: S9 581(S)-1/8, S9 581(S)RF-1/8, S9 582-1/8
22
***
10,5
M5
**
ca. 140
24,5
G1/8
33,5
42,5
24
128
14
pst
5,6
3,2
ca.208
4
87,5
18
55,5
G1/8
18
1
54
8
5
2
18
16,6 3
pst
12
**
15,5
* 5,5
56
5
15,5
16
17
14
40
S9 581 -1/8
35
5 S9 581S-1/8 63
5,6
3,2
4
18
55,5
54
G1/8
1
18
* Manual override
80
8
2
18
40
Solenoid for use in EX areas
Dimensions
X = 15,5 mm
For order instructions see page 73, 74, characteristics see page 44-47
Dimensions in mm
57
Basic valve for panel mounting actuatos – Type: S9 590RF-1/8 Mounting diameter
40
Mounting diameter Ø22 mm Mounting diameter Ø30 mm
28
28
38
47
12
94,5
4
18
55,5
92
1
G1/8
2
3
10
40
Rotary lever, indexed – Type: 12T-22, 12T-30 Mushroom pushbutton – Type: 15T-RF-22, 15T-RF-30
Mounting diameter Ø22 mm Mounting diameter Ø30 mm Mounting diameter Ø22 mm Mounting diameter Ø30 mm
∅ ∅
∅ ∅
°
°
∅ ∅
58
Rotary switch – Type: 17T-22, 17T-30 Rotary lever with spring return – Type: 12T-RF-22, 12T-RF-30
Mounting diameter Ø22 mm Mounting diameter Ø30 mm Mounting diameter Ø22 mm Mounting diameter Ø30 mm
°
°
°
°
Mushroom pushbutton emergency-0ff – Type: 18T-22, 18T-30 Locking switch – Type: 16T-22, 16T-30
Mounting diameter Ø22 mm Mounting diameter Ø30 mm Mounting diameter Ø22 mm Mounting diameter Ø30 mm
∅ ∅
∅ ∅
For order instructions see page 73, 74, characteristics see page 44-47
Dimensions in mm
59
5/2 Way Valves Weight (mass) kg
Description Type Weight (mass)
Series S9 Hand lever, indexed S9 511-1/4 0.520
– with spring return S9 511RF-1/4 0.520
G1/4 Safety hand lever S9 511S-1/4 0.520
Rotary lever, indexed S9 512-1/4 0.520
Actuation systems:
– Hand lever – with spring return S9 512RF-1/4 0.520
– Safety hand lever Pneumatic, by permanent signal S9 561RF-1/4 0.490
– Pneumatic
– Electrical pilot operated Pneumatic, by impulse S9 561-1/4 0.510
– Electrical pilot operated with – with biased position S9 562-1/4 0.510
external pilot air
Electrical, by permanent signal S9 581(S) RF-1/4 0.600
Versions Electrical, by impulse S9 581(S)-1/4 0.700
– With external pilot air – with biased position S9 582(S)-1/4 0.700
– With biased position
– Version to ATEX Standard
°
60
Rotary lever actuated Electrically actuated
Type: S9 512-1/4, S9 512RF-1/4 Type: S9 581(S)-1/4, S9 582(S)-1/4, S9 581(S)RF-1/4
79,5
33° 33° 44
25 12
17
43,5
55
66
14
65
5
120
4
22
G1/4
67
22
22
2
3
12
6,5 32
6
52
only for type
Pneumatically actuated
* Manual override
** Operating pressure supply pst only for type S9 581S
25
*** Solenoid width = 30 mm on low wattage coil version
12,5
G1/8
22,5
22
33,5
44,5
14
5
Solenoid for use in EX areas
5,5
66
4
Dimensions
22
o 7,5
o 4,2
98,5
G1/4
111
1
67
22
11
2
22
Solenoid width 30 mm
4,5 Cable lenth
3 see Order Instructions
12
12,5
S9 561-1/4
6 S9 562-1/4
52
X = 15,5 mm
For order instructions see page 73, 74, characteristics see page 44-47
Dimensions in mm
61
5/2 Way Valves Weight (mass) kg
Series S9 Description
Hand lever, indexed
Type
S9 511-1/2
Weight (mass)
0.120
– with spring return S9 511RF-1/2 0.120
G1/2
Safety hand lever S9 511S-1/2 0.120
Actuation systems: Rotary lever, indexed S9 512-1/2 0.120
– Hand lever
– with spring return S9 512RF-1/2 0.120
– Safety hand lever
– Pneumatic Pneumatic, by permanent signal S9 561RF-1/2 0.800
– Electrical pilot operated
Pneumatic, by impulse S9 561-1/2 0.900
Versions: – with biased position S9 562-1/2 0.900
– With external pilot air
Electrical, by permanent signal S9 581(S) RF-1/2 1.000
– With biased position
– Version to ATEX Standard Electrical, by impulse S9 581(S)-1/2 1.045
– with biased position S9 582-1/2 1.045
62
Rotary lever actuated – Type: S9 512-1/2, S9 512RF-1/2 Electrically actuated
Type: S9 581(S)-1/2, S9 582-1/2, S9 581(S)RF-1/2
6 deep
Pneumatically actuated only for type
Type: S9 561-1/2, S9 561RF-1/2, S9 562-1/2 S9 581-1/2
S9 582-1/2
S9 581S-1/2
* Manual override
Solenoid for use in EX areas
Dimensions
6 deep
Solenoid width 30 mm Cable lenth
see Order Instructions
S9 561-1/2
S9 562-1/2
X = 21 mm
For order instructions see page 73,74, characteristics see page 44-47
Dimensions in mm
63
5/3 Way Valves Weight (mass) kg
Description Type * Weight (mass)
Series S9 Hand lever S9 511.-1/8 0,195
– with spring return S9 511RF.-1/8 0,195
G1/8 Safety hand lever S9 511S.-1/8 0,195
Pneumatic, by permanent signal S9 561RF.-1/8 0,180
Actuation systems:
– Hand lever Electrical, by permanent signal S9 581RF.-1/8 0,425
– Safety hand lever Electrical, by permanent signal S9 581S-RF.-1/8 0,425
– Pneumatic
– Electrical pilot operated * Type code for middle position functions
G = middle position closed
Versions: E = middle position exhausted
– With external pilot air B = middle position pressurized
– Version to ATEX Standard
°
41
48
14
G1/8
5
95
4
18
55,5
18
1
2
18
12
5,5 22
5
40
64
Pneumatically actuated – Type: S9 561RF.-1/8
16
17
26
14
35
5
5,6
3,2
18
55,5
54
G1/8
1
18
88
8
18
4
3
12
16,6 5,5
22 5
40
*
M5
ca. 140
pst ***
33,5
24
42,5
128
14
ca. 208
5
5,6
3,2
4
87,5
18
55,5
G1/8
18
1
8
X = 15,5 mm
2
18
4
16,6 3
pst ***
* 5,5
56
15,5
40
63
* Manual override
** Solenoid width = 30 mm on low wattage coil version
*** Operating pressure supply pst only for type S9 581S
For order instructions see page 75-77, characteristics see page 44-47
Dimensions in mm
65
5/3 Way Valves Weight (mass) kg
Description Type * Weight (mass)
Series S9 Hand lever, indexed S9 511.-1/4 0.520
– with spring return S9 511RF.-1/4 0.530
G1/4 Safety hand lever S9 511S.-1/4 0.520
Rotary lever, indexed S9 512.-1/4 0.520
Actuation systems:
– Hand lever –with spring return S9 512RF.-1/4 0.530
– Safety hand lever Pneumatic, by permanent signal S9 561RF.-1/4 0.530
– Pneumatic
– Electrical pilot operated Electrical, by permanent signal S9 581RF.-1/4 0.700
* Type code for middle position functions
Versions: G = middle position closed
– Version to ATEX Standard E = middle position exhausted
B = middle position pressurized
66
Rotary lever actuated – Type: S9 512.-1/4, S9 512RF.-1/4 Electrically actuated – Type: S9 581RF.-1/4
32
**
22
*
M5
10
29,5
G1/8
30
41
14
ca. 159
25
52
ca.231
148
5,5
4
o 7,5
o 4,2
22
106
G 1/4
22
1
67
66
11
22
4,5
3
6,5
12
20
6 *
62
Pneumatically actuated – Type: S9 561RF.-1/4
15,5
52
63
* Manual override
** Solenoid width is 30 mm on low wattage coil version
Solenoid for use in EX areas
Dimensions
X = 15,5 mm
For order instructions see page 75-77, characteristics see page 44-47
Dimensions in mm
67
5/3 Way Valves Weight (mass) kg
Description Type * Weight (mass)
Series S9 Hand lever, indexed S9 511.-1/2 1.200
– with spring return S9 511RF.-1/2 1.200
G1/2 Safety hand lever S9 511S.-1/2 1.200
Rotary lever, indexed S9 512.-1/2 1.200
Actuation systems:
– Hand lever – with spring return S9 512RF.-1/2 1.200
– Safety hand lever Pneumatic, by permanent signal S9 561RF.-1/2 0.900
– Pneumatic
– Electrical pilot operated Electrical, by permanent signal S9 581RF.-1/2 1.045
* Type code for middle position functions
Versions: G = middle position closed
– Version to ATEX Standard E = middle position exhausted
B = middle position pressurized
68
Rotary lever actuated – Type: S9 512.-1/2, S9 512RF.-1/2 Electrically actuated – Type: S9 581RF.-1/2
70 40
68 32,5
21 22 **
29
39
57
14
73
5
G1/2
4
32
201,5
1
283
190
149
100
16
32
9,56 deep
5,3
6,5 2
32
3
*
12
7
29
Pneumatically actuated – Type: S9 561RF.-1/2
70
70
6,5
7 40
G1/8
* Manual override
9
47
14
63
5
G1/2
4
32
140
1
158
139
100
16
32
9,5 6 deep
5,3
2
Solenoid for use in EX areas
32
3
Dimensions
12
X = 21 mm
For order instructions see page 75-77, characteristics see page 44-47
Dimensions in mm
69
3/2 Way Valves – Standard versions
Actuation System Symbol Mounting Order Instructions Page
Ø (mm) Type Order No.
Hand lever, 2 S9 311-1/8 PA 10293 48
12
indexed S9 311-1/4 PA 12708 52
1 3
S9 311-1/2 PA 16404 54
Hand lever, 2 S9 311RF-1/8 PA 10294 48
12 10
spring return S9 311RF-1/4 PA 12709 52
1 3
S9 311RF-1/2 PA 16405 54
Hand lever 12 2
secured in 2 switching S9 311S-1/4 PA 12710 52
positions
1 3
S9 311S-1/2 PA 16406 54
Rotary lever, 2
12
indexed S9 312-1/4 PA 12711 53
1 3
S9 312-1/2 PA 16407 45
Rotary lever, 2
12 10
spring return S9 312RF-1/4 PA 12712 53
1 3
S9 312RF-1/2 PA 16408 55
Pneumatic, 2 S9 361RF-1/8 PA 10295 49
by permanent signal 12 10
S9 361RF-1/4 PA 12713 53
1 3
S9 361RF-1/2 PA 16409 55
Pneumatic, 2 S9 361-1/8 PA 10296 49
by impulse 12 10
S9 361-1/4 PA 12714 53
1 3
S9 361-1/2 PA 16410 55
Pneumatic, by impulse, 2
with biased position 12 10
S9 362-1/4 PA 12715 53
1 3
S9 362-1/2 PA 16411 55
Basic valve for 2 S9 390RF-1/8 PA 10307 50
10
panel mounting 12
1 3
70
Actuation System Symbol Mounting Order Instructions Page
Ø (mm) Type Order No.
Rotary switch 22 17T-22 KX 9360 51
30 17T-30 KX 9319
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Standard version 230V 50/60Hz 110 V = 61 –
24V = 60V 50/60Hz 02 –
Low wattage version 24V = 13 –
230V 50/60Hz 69 –
EX Area versions to ATEX standard see page 72
71
EX Area versions to ATEX Standard
Category, type of ignition protection
Single valve: II 2G c T4 T135°C -10°C≤Ta≤+60°C
Solenoid/individual use: II 2G EEx m II T5 -20°C≤Ta≤+50°C
Solenoid/manifold mounting: II 2G EEx m II T5 -20°C≤Ta≤+40°C
Solenoid version Nominal Applicable for Key code ATEX Type ad-
voltage diton
Solenoid 24V = 48 Atex
– with cable 1.2 m
– with cable 3 m 24V = 45 Atex
– with cable 5 m 24V = 46 Atex
– with cable 10 m 24V = 47 Atex
– with cable 1.2 m 24V 50/60Hz 99 Atex
– with cable 1.2 m 110V 50/60Hz 97 Atex
– with cable 1.2 m 230V 50/60Hz 98 Atex
Example for valves in ATEX-Version:
– for valves Series S9-G1/8, S9-G1/4, S9-G1/2
Please add behind the Standard Order No. “ATEX“
Type: S9 381RF-1/8-NC-4633
Order No. PA10297-4633ATEX
72
Order Instructions – 5/2 Way Valves – Standard versions
Actuation System Symbol Mounting Order Instructions Page
Ø (mm) Type Order No.
Hand lever, 4 2 S9 511-1/8 PA 10308 56
14
indexed S9 511-1/4 PA 12671 60
51 3
S9 511-1/2 PA 16367 62
Hand lever, 4 2 S9 511RF-1/8 PA 10309 56
14 12
spring return S9 511RF-1/4 PA 12672 60
513
S9 511RF-1/2 PA 16366 62
Hand lever 14
4 2 S9 511S-1/8 PA 10368 57
secured in 2 switching S9 511S-1/4 PA 12673 60
positions
513
S9 511S-1/2 PA 16368 62
Rotary lever, 14
4 2
51 3
73
Order Instructions – 5/2 Way Valves – Standard versions
Actuation System Symbol Mounting Order Instructions Page
Ø (mm) Type Order No.
Rotary switch 22 17T-22 KX 9360 58
30 17T-30 KX 9319
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Standard version 230V 50/60Hz 110 V = 61 –
24V = 60V 50/60Hz 02 –
Low wattage version 24V = 13 –
230V 50/60Hz 69 –
EX Area versions to ATEX Standard
Category, type of ignition protection
Single valve: II 2G c T4 T135°C -10°C≤Ta≤+60°C
Solenoid/individual use: II 2G EEx m II T5 -20°C≤Ta≤+50°C
Solenoid/manifold mounting: II 2G EEx m II T5 -20°C≤Ta≤+40°C
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Solenoid 24V = 48 Atex
– with cable 1.2 m
– with cable 3 m 24V = 45 Atex
– with cable 5 m 24V = 46 Atex
– with cable 10 m 24V = 47 Atex
– with cable 1.2 m 24V 50/60Hz 99 Atex
– with cable 1.2 m 110V 50/60Hz 97 Atex
– with cable 1.2 m 230V 50/60Hz 98 Atex
Example for valves in ATEX-Version:
– for valves Series S9-G1/8, S9-G1/4, S9-G1/2
Please add behind the Standard Order No. “ATEX“
Type: S9 581RF-1/8-4633
Order No. PA10312-4633ATEX
74
Order Instructions – 5/3 Way Valves – Standard versions
Actuation System Symbol Order Instructions Page
Type Order No.
Hand lever, 4 2
S9 511G-1/8 PA 10321 64
secured in 3 operating 14
S9 511G-1/4 PA 12687 66
positions
513 S9 511G-1/2 PA 16369 68
4 2 S9 511E-1/8 PA 10322 64
14
S9 511E-1/4 PA 12688 66
513 S9 511E-1/2 PA 16370 68
4 2 S9 511B-1/8 PA 10323 64
14
S9 511B-1/4 PA 12689 66
513
S9 511B-1/2 PA 16371 68
Hand lever, 4 2 S9 511RFG-1/8 PA 10324 64
spring return to 14 12
S9 511RFG-1/4 PA 12690 66
middle position
513
S9 511RFG-1/2 PA 16372 68
4 2 S9 511RFE-1/8 PA 10325 64
14 12
S9 511RFE-1/4 PA 12691 66
513 S9 511RFE-1/2 PA 16373 68
4 2 S9 511RFB-1/8 PA 10326 64
14 12
S9 511RFB-1/4 PA 12692 66
51 3
S9 511RFB-1/2 PA 16374 68
Hand lever, 14 4 2 S9 511SG-1/8 PA 10327 64
secured in 3 operating S9 511SG-1/4 PA 12693 66
positions
5 13
S9 511SG-1/2 PA 16375 68
14 4 2 S9 511SE-1/8 PA 10328 64
S9 511SE-1/4 PA 12694 66
513
S9 511SE-1/2 PA 16376 68
14 4 2 S9 511SB-1/8 PA 10329 64
S9 511SB-1/4 PA 12695 66
513
S9 511SB-1/2 PA 16377 68
Rotary lever, 4 2
indexed in 3 operating 14
S9 512G-1/4 PA 12696 67
positions
513
S9 512G-1/2 PA 16380 69
4 2
14
S9 512E-1/4 PA 12697 67
513
S9 512E-1/2 PA 16381 69
4 2
14
S9 512B-1/4 PA 12698 67
513
S9 512B-1/2 PA 16382 69
75
Actuation System Symbol Order Instructions Page
Type Order No.
Rotary lever, 4 2
14 12
spring return to S9 512RFG-1/4 PA 12699 67
middle position 513
S9 512RFG-1/2 PA 16383 69
4 2
14 12
S9 512RFE-1/4 PA 12700 67
513
S9 512RFE-1/2 PA 16384 69
4 2
14 12
S9 512RFB-1/4 PA 12701 67
51 3
S9 512RFB-1/2 PA 16385 69
Pneumatic, 4 2 S9 561RFG-1/8 PA 10330 65
by permanent signal 14 12
S9 561RFG-1/4 PA 12702 67
51 3
S9 561RFG-1/2 PA 16168 69
spring return to 4 2 S9 561RFE-1/8 PA 10331 65
middle position 14 12
S9 561RFE-1/4 PA 12703 67
513
S9 561RFE-1/2 PA 16169 69
4 2 S9 561RFB-1/8 PA 10332 65
14 12
S9 561RFB-1/4 PA 12704 67
5 13
S9 561RFB-1/2 PA 16170 69
Electrical 4 2 S9 581RFG-1/8-.. PA 10333-..33 65
by permanent signal 14 12
S9 581RFG-1/4-.. PA 12705-..33 67
51 3
S9 581RFG-1/2-.. PA 16176-..33 69
spring return to 4 2 S9 581RFE-1/8-.. PA 10334-..33 65
middle position 14 12
S9 581RFE-1/4-.. PA 12706-..33 67
513
S9 581RFE-1/2-.. PA 16177-..33 69
4 2 S9 581RFB-1/8-.. PA 10335-..33 65
14 12
S9 581RFB-1/4-.. PA 12707-..33 67
513
S9 581RFB-1/2-.. PA 16178-..33 69
76
Actuation System Symbol Order Instructions Page
Type Order No.
Electrical 4 2 S9 581S-RFG-1/8-.. PA 10377-..33 65
14 12
by permanent signal S9 581S-RFG-1/4-.. PA 12925-..33 67
pst 513 pst
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Standard version 230V 50/60Hz 110 V = 61 –
24V = 60V 50/60Hz 02 –
Low wattage version 24V = 13 –
230V 50/60Hz 69 –
EX Area versions to ATEX Standard
Category, type of ignition protection
Single valve: II 2G c T4 T135°C -10°C≤Ta≤+60°C
Solenoid/individual use: II 2G EEx m II T5 -20°C≤Ta≤+50°C
Solenoid/manifold mounting: II 2G EEx m II T5 -20°C≤Ta≤+40°C
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Solenoid 24V = 48 Atex
– with cable 1.2 m
– with cable 3 m 24V = 45 Atex
– with cable 5 m 24V = 46 Atex
– with cable 10 m 24V = 47 Atex
– with cable 1.2 m 24V 50/60Hz 99 Atex
– with cable 1.2 m 110V 50/60Hz 97 Atex
– with cable 1.2 m 230V 50/60Hz 98 Atex
Example for valves in ATEX-Version:
– for valves Series S9-G1/8, S9-G1/4, S9-G1/2
Please add behind the Standard Order No. “ATEX“
Type: S9 581RFG-1/8-4633
Order No. PA10333-4633ATEX
77
3/2, 5/2 and Weight (mass) kg
Description Weight (mass) – Connection size
5/3 Way Valves G1/8 G1/4
Series S9 3/2 Way Valve, by permanent signal 0.137 0.370
3/2 Way Valve, by impulse 0.147 0.430
G1/8, G1/4 5/2 Way Valve, by permanent signal 0.160 0.490
5/2 Way Valve, by impulse 0.170 0.510
Actuation systems: 5/3 Way Valve, by permanent signal 0.180 0.530
Pneumatic
– AND
– OR Possible combinations:
– TIMER
Dimensions in mm
78
Valve Combinations with Logic Elements – 3/2, 5/2 and 5/3 Way Valves
Pneumatic
Actuation 61
OR
Actuation 63
Timer Dimension Table and adjustment ranges
Actuation 64
Adjustment range Dimension A [mm]
Standard version: 0.1 to 15 103 (133*)
Countersunk
adjustment screw 0.1 to 30 117 (147*)
On request: 0.1 to 60 150 (180*)
Rotary knob version * Version with rotary knob
(optional)
AND
Actuation 65
UND
Actuation 65
Order Instructions
S9 5 63 / 65 – RFG – 1/4
65 AND
Dimensions in mm * only with Connection size
G1/4
79
80
Contents Solenoid Poppet
Version Actuation
Characteristics
Page
Dimensions Order Instructions
Valves
Overview
3/2 Way Valves electrical 82 83 83 directly actuated
Series EV-M5 (G1/8)
Series EV-M5 (G1/8)
3/2 Way Valves electrical 84 85 86
Series V9-G1/8 Series V9-G1/8
81
3/2 Way Characteristics – Series EV
Characteristics Symbol Unit Description
Screw-In Valve General Features
Series EV Actuation Electrical directly operated
Type Poppet valve, normally closed
G1/8-M5 Mounting Screws into thread G1/8
Tube connection Thread
Actuation System: Port size Port 1: M5, port 2: G1/8
– Electrical, directly actuated
Weight kg 0.1
Nominal diameter mm 1
Installation in any position
Ambient temperature Tmin. / max. °C -10 to Note :
range +60 Please consult us for operating
Medium temperature Tmin. / max. °C -10 to temperatures below 0° C
range +60
Medium Filtered compressed air (30µ)
Lubrication With or without oil mist lubrication
(We recommend the use of mineral oil type VG
32 to ISO 3448)
Pneumatic Characteristics
Nominal pressure pmin. / max. bar 6
Operating pressure range pmin. / max. bar 0 – 10
Nominal flow QN l/min 30
Actuation
Electrical Direct
Voltage type Alternating Direct current
current
(50/60Hz)
Nominal voltage (1
82
3/2 Way Valve – Type: EV 381RF-M5
Dimensions in mm
83
3/2 Way Valves Characteristics – Series V9-G1/8
Characteristics Symbol Unit Description
Series V9 General Features
Type Poppet valve
NW 1.3 and 2.5 Mounting 2 Screws M3 (NW 2.5: 2 x M4)
Tube connection Thread
Actuation System:
– Electrically actuated, Thread G1/8 – 8 deep
directly actuated Weight kg NW 1.3: 0.140
NW 2.5: 0.320
Versions:
Installation In any position
Threaded version
– Normally closed Ambient temperature Tmin. / max. °C -10 Note :
– Normally open range (1 +60 Please consult us for operating
– With manual override Medium temperature Tmin. / max. °C -10 temperatures below 0° C
range (1 +70
P-moulding mounting:
– See Order Instructions Medium Filtered compressed air
Lubrication With or without oil mist lubrication
(We recommend the use of mineral oil type VG
32 to ISO 3448)
Pneumatic Characteristics
Nominal pressure pmin. / max. bar 6
Operating pressure pmin. / max. bar NW 1.3: 0–10
range NW 2.5: 0-7
Nominal flow QN l/min NW 1.3: 37
NW 2.5: 150
Actuation
Electrical Direct
Voltage type Alternating Direct current
current (50/60Hz)
Nominal voltage
– Standard version Un V 230 ±10% 24 ±10% other voltages
– Low wattage version Un V 230 ±10% 24 ±10% on request
(not for (not for
V9-NW 2.5) V9-NW 2.5)
Initial power consumption
– Standard version VA (W) NW 1.3: 11 NW 1.3: 4.8
NW 2.5: 11.5 NW 2.5: 10
– Low wattage version VA (W) 7.8 2.7
Continuous consumption
– Standard version VA (W) NW 1.3: 8.5 NW 1.3: 4.8
NW 2.5: 7.5 NW 2.5: 7.5
– Low wattage version VA (W) 4.9 2.7
Duty cycle ED % 100
Electrical protection IP IP 65 to DIN 40050 (applise only to solenoid
with connector)
Connection NW 1.3: connector to DIN EN 175301-803
form B – industrial standard
NW 2.5: connector to DIN EN 175301-803
form A – industrial standard
84
(1
not suitable for P-supply
Type: V9 381RF-1/8NG (NO(1)– NW 1.3
manifold mounting
Type: V9 381H-RF-1/8NG (NO(1)– NW 1.3
∅
∅
* Manual override
Dimensions in mm
85
Order Instructions – 3/2 Way Valves – Series V9
Actuation System Symbol Nominal Order Instructions Page
Size Type Order No.
(mm)
2
Electrical, 12 10 NW 1.3 V9 381RF-1/8-NC-.. PA 10362-..33 84, 85
by permanent signal
13 NW 2.5 V9 381RF-1/8-NC-.. PA 10369-..33 84, 85
2
12
10
NW 1.3 V9 381H-RF-1/8-NC-.. PA 10363-..33 84, 85
1 3
NW 2.5 V9 381H-RF-1/8-NC-.. PA 10370-..33 84, 85
2
12 10
NW 1.3 V9 381H-RF-1/8-NO-.. PA 10367-..33 84, 85
1 3
86
Contents Valve Islands
Version Actuating Page
electrical Characteristics Dimension Order
over Table Instructions
Series IM20-G1/8
Valve Islands with Sub-D plug 88 89, 90 91 Series IM20-G1/4
Multipole Connector industrial connector
Accessories – – 92
87
Valve Islands with Multipole Connector
Characteristics Symbol Unit Description
General Features
Type IM20-1/8 IM20-1/4
Mounting 4 Screws – see drawing 4 Screws – see drawing
Connection size
– air supply and exhaust G1/4 both sides G3/8 both sides
– valve outlets G1/8 G1/4
Size for valve positions 22 33
Installation In any position
Ambient and medium Tmin °C –10 Note: Please consult us for operating temperatures below 0° C
temperature range Tmax °C +50
Medium Filtered compressed air
Lubrication With or without oil mist lubrication
(We recommend the use of mineral oil type VG 32 to ISO 3448)
Material
– Base plate Al
– Valve housing Al
– Seals NBR
Durability of valves 10 x 106 operations
No. of valves positions 4 – 6 – 8 – 10 – 12 –14–16 (1
Actuation
Electrical By control system
Voltage type Direct current
Nominal voltage Un V 24 ±10%
Power consumption W 2.5
Mass/ground Minuspol
Electrical protection IP IP65 (applise only to the electrically part)
– Input clamps IP IP20
– Input plug IP IP65
Connection
– Multipole Connector 25-pin sub-D connector or 24-pin industrial connector
– Sensor inputs Ladder clamps or M8 x 14-pin connectors
Status indication LED
Protective circuit Integrated
(1
other numbers of valves can be fitted via the use of blanking plates.
(2
Version “middle position vented“ 1000 l/min
88
Multipole Island with sub-D-multipole connector 25pole (or heavy industrial connector) and
16 M8 4-pin feedback inputs with 44pin sub-D connector Valve Islands
with
Multipole
Feedback inputs with
either M8 4-pin connectors Sub-D connector Version with
sub-D-multipole connector
Connection
or clamp connections 44pole
25pole Series IM20
springreturn
– 5/2 Way Impulse Valves
– 5/3 Way Valves
with spring return
to middle position
– middle position pressurized
Versions:
– Connection
Dimensions in mm
89
Valve Islands Multipole Island with 25-pin sub-D connector (or heavy duty industrial connector)
and 16 M8 4-pin feedback inputs with 44-pin sub-D connector
with
Multipole Feedback inputs with
44-pin sub-D Version with
Connection either M8 4-pin connectors
or clamp connections
connector 25-pin sub-D connector
industrial
G1/4 connector
– 5/2 Way Valves with
spring return
– 5/2 Way Impulse Valves
– 5/3 Way Valves
to middle position
– middle position exhausted
– Connection
with sub-D connector
industrial connector
Dimensions in mm
90
Order Instructions – Valve Islands
Example:
M8 assembled with:
1 item 5/2 Way Valves S9 581-1/8
Input module
Ident-No. Valve position
Flow divider
connection
Number of
of channel
Electrical
Position
divider
inputs
Valves
1 2 3 4 5 6 7 8 9 10 11 12
Example P A 1 0 3 8 1 D S 0 8 M M M M M M M J
04 06 08 10 12
even number of valve positions only
For order, please use the Important: Please specify the code for
neutral order form on the desired valve types
page 135
Input Modules
K Pins IP20
Valve Islands – Sizes S M8 IP65 connector
PA Type: IM20-1/8 04-08-12 Number of inputs
10381 Connections: 16-20-24
G1/8: valve outlets 28-32
G1/4: base plate
PA12867 Type: IM20-1/4 Dual Pressure Operating
Connections:
J with channel
G1/4: valve outlets
divider in port 1
G3/8: base plate
01 – 11 Position of channel
divider to valve
Electrical Connection position
Multipol-Version
DS with sub-D-Connection Ordering Code for Valves and Cover Plates
HI with industrial con- Code Symbol Description
nector A – Cover plate on valve
M 14
4 2
12
5/3 Way Solenoid Valve,
permanent signal with spring
Valves return Type: S9 581RF-..
5 13
04 to 4 valves
06 5 and 6 valves J 14
4 2
12
5/3 Way Solenoid Valve,
Impulse version
08 7 and 8 valves Type: S9 581RF-..
513
10 9 and 10 valves
G 4 2 5/3 Way Solenoid Valve,
12 11 and 12 valves 14 12 spring return to middle position,
middle position closed
14 13 and 14 valves 51 3 Type: S9 581RFG-..
16 15 and 16 valves B 4 2 5/3 Way Solenoid Valve,
14 12
spring return to middle position,
middle position pressurized
513
Type: S9 581RFB-..
E 4 2 5/3 Way Solenoid Valve,
14 12 spring return to middle position,
middle position exhausted
513 Type: S9 581RFE-..
91
Accessories for Cable with sub-D plug
Number of Cable length Order Instructions Figure
Valve Islands poles Type Order No.
IM20 25 1.0 m GSK-25-1 KL9012
25 3.0 m GSK-25-3 KL9013
with Multipole 25 5.0 m GSK-25-5 KL9014
Connector 44 5.0 m GSK-44-5 KL9005
– Cable with sub-D plug Heavy duty industrial connector with cable
– Heavy duty industrial
connector Number Cable length Order Instructions Figure
– Straight plug M8 4pole of poles Type Order No.
24 5.0 m K-IST-24 KL9003
92
Contents P- and RPS-
Version Connection Page
Supply
Dimension Table Order Instructions
P-Manifolds G1/8 92 92 Manifolds
G1/4 93 93
G1/2 94 94
for directional valves
RPS-Manifolds G1/8 95 95 S9-G1/8
G1/4 95 95 S9-G1/4
93
P-Supply P-Supply Manifold with short mounting brackets Type: PLK-1/8-..
Manifold 21 23
A
23
Series
PLK, PL
11
109
86
25
G1/4
design. 13 10 20
95,5
Material
Description Material
P-Manifold Al anodized
Mounting Steel
A
bracket passivated
21 23 23
Galvanized 11 25
Screws
steel M3
ca. 160
O-Ring NBR
G1/4
18
16,6
59,5
ø6,5
4
13 30 10 20
B 40
Dimensions in mm
94
Dimension Table (mm)
Type Number of Valves A B
PLK-1/8-2 2 65 79
PL-1/8-2 2 65 79
PLK-1/8-3 3 88 102
PL-1/8-3 3 88 102
PLK-1/8-4 4 111 125
PL-1/8-4 4 111 125
PLK-1/8-5 5 134 148
PL-1/8-5 5 134 148
PLK-1/8-6 6 157 171
PL-1/8-6 6 157 171
PLK-1/8-7 7 180 194
PL-1/8-7 7 180 194
PLK-1/8-8 8 203 217
PL-1/8-8 8 203 217
PLK-1/8-9 9 226 240
PL-1/8-9 9 226 240
PLK-1/8-10 10 249 263
PL-1/8-10 10 249 263
95
P-Supply P-Manifold with short mounting brackets Type: PLK-1/4-..
Manifolds
Series
PLK, PL
Series S9-G1/4
Material
Description Material
P-Manifold Al anodized
Mounting Steel passi-
bracket vated
Galvanized
Screws
steel
O-Ring NBR
Dimensions in mm
96
Dimension Table (mm)
Type Number of valves A B
PLK-1/4-2 2 89 99
PL-1/4-2 2 89 99
PLK-1/4-3 3 122 132
PL-1/4-3 3 122 132
PLK-1/4-4 4 155 165
PL-1/4-4 4 155 165
PLK-1/4-5 5 188 198
PL-1/4-5 5 188 198
PLK-1/4-6 6 221 231
PL-1/4-6 6 221 231
PLK-1/4-7 7 254 264
PL-1/4-7 7 254 264
PLK-1/4-8 8 287 297
PL-1/4-8 8 287 297
PLK-1/4-9 9 320 330
PL-1/4-9 9 320 330
PLK-1/4-10 10 353 363
PL-1/4-10 10 353 363
97
P-Manifolds P-Manifold with short mounting brackets – Type: PL-1/2-..
Series PL
allow a clear, space-saving
design.
∅
of 2-4 item.
Dimensions in mm
98
RPS-manifold – Type: RPSL-S9-1/8-.
Dimension A and B see Tabelle RPS-Manifolds
Series RPSL
for directional valves
Series S9-G1/8
RPS-supply manifolds reduce
and simplify tubing. They
allow a clear, space-saving
design.
The RPS manifolds have
a common compressed air
supply (P) and common vent
lines (R,S).
Valves can be mounted in
groups of 2-10.
– RPS-Manifolds for more
valves on request
99
RPS-Manifolds RPS-Supply Manifold – Type: RPSL-S9-1/4-..
Series S9-G1/4
allow a clear, space-saving
design.
The RPS manifolds have
a common compressed air
supply (P) and common vent
lines (R,S).
Valves can be mounted in
groups of 2-10.
– RPS-Manifolds for more
valves on request
Dimensions in mm
100
Contents
Special Valves
Version Actuation Port size Page
Characteri- Dimensions Order Connection size
stics Instructions G1/8 to G2
Overview
3/2, 5/2 and 5/3 Way Electrical G1/8 102, 103 104-106 107
Valves with NAMUR- G1/4
connections
Series S9
5/2 Way Valves for Two Hand G1/8 108, 109 109 110
Hand Operation G1/4
Series S9
Time Delay Valve for Pneumatic G1/8 108, 109 110 110
2-Hand Safety Start Valve (Timer)
5/2 Way Oscillating Valves, Pneumatic G1/4 111 111 112
Series S9
3/2 and 5/2 Way- Pedal G1/4 113 113 114
Pedal actuated valve,
Series F
2/2 Way Stop Valve Pneumatic G1/2 115 116 116
Series ARKV G3/4
G1
G11/2
G2
101
Way Valves Series S9 – G1/8, G1/4 NAMUR
Characteristics Symbol Unit Series S9
with NAMUR G1/8 G1/4
Connections Actuation Electrically actuated Electrically actuated
General Features
Characteristics Type Spoolvalve Spoolvalve
for Standard Valves Mounting 2 Screws M5 2 Screws M6
Tube connection Thread/NAMUR Thread/NAMUR
connections connections
Thread G1/8 – 7,4 deep G1/4 – 11 deep
Weight kg 0.245 0.600
permanent signal version permanent signal version
kg 0.340 0.700
impulse version impulse version
Installation In any position In any position
Ambient temperature Tmin. / max. °C -10 to +60 -10 to +60
range (1
Medium temperature Tmin. / max. °C -10 to +60 -10 to +60
range (1
Medium Filtered compressed air
Lubrication With or without oil mist lubrication
(We recommend the use of mineral oil type
VG 32 to ISO 3448)
Pneumatic Characteristics
Nominal pressure pmin. / max. bar 6
Operating pressure range
– permanent signal pmin. / max. bar 2–10
version
– impulse version pmin. / max. bar 1.5–10
Nominal flow QN l/min 500 1300 (3
Actuation
Electrical Pilot operated
Voltage type Alternating current Direct current
(1 Note : (50/60Hz)
Please consult us for opera- Nominal voltage
ting temperatures below 0° C
– Standard version Un V 230 ±10% 24 ±10% other voltages
(2 Low wattage version on request
connector DIN EN – Low wattage version Un V 230 ±10% 24 ±10% other voltages
175301-803 form A on request
(3 Version “middle position Initial power consumption
vented“ 1000 l/min
– Standard version VA (W) 8.5 2.5
– Low wattage version VA (W) 6.6 2.1
Continuous consumption
– Standard version VA (W) 6.0 2.5
– Low wattage version VA (W) 3.9 2.1
Duty cycle ED % 100
Electrical protection IP IP 65 to DIN 40050
(applise only to solenoid with connector)
Connection Plug to DIN EN 175301-803
form B – industrial standard (2
102
Series S9 – G1/8, G1/4 NAMUR
Characteristics Symbol Unit Series S9
Way Valves
G1/8 G1/4 with NAMUR
Actuation
General Features
Electrically actuated Electrically actuated
Connections
Type Spool valve Spool valve
Mounting 2 Screws M5 2 Screws M6 Characteristics for
Tube connection Thread/NAMUR Thread/NAMUR Valves in EX Areas
connections connections
Weight kg 0.245 0.600
permanent signal version permanent signal version
0.340 0.700
impulse version impulse version
Installation In any position In any position
Ambient temperature Tmin. / max. °C -10 to +60 -10 to +60
range (1
Medium temperature Tmin. / max. °C -10 to +60 -10 to +60
range (1
Medium Filtered, unlibricated compressed air – free from
water and dirt to ISO 8573-1
Solids: Class 7 particle < 40µm for gas
Water content: pressure dew point +3°C, Class 4,
but at least 5 °C below minimum operating tempe-
rature
Pneumatic Characteristics
Nominal pressure pmin. / max. bar 6
Operating pressure range
– permanent signal version pmin. / max. bar 2–8
– impulse version pmin. / max. bar 1.5–8
Nominal flow QN l/min 500 1300 (3
Actuation
Electrical Pilot operated
Certification EC Type Test Certificate for single valve:
not required for mechanical units
EC Type Test Certificate for solenoid coil: PTB-No.
03 Ex IEC 2019X and PTB 03 ATEX 2018X to T5
Category, Single valve: II 2G c T4 T135°C (1 Note : Please consult us for
type of ignition -10°C≤Ta≤+60°C operating temperatures
protection Solenoid/individual use: below 0° C
II 2G EEx m II T5 -20°C≤Ta≤+50°C (2 Maximum power if warmed
Solenoid/manifold mounting: up to thermal load limit
II 2G EEx m II T5 -20°C≤Ta≤+40°C (3 Version “middle position
Voltage type Alternating current Direct current vented“ 1000 l/min
(50/60Hz)
Nominal voltage Un V 230 ±10% 24 ±10%
110 ±10% other voltages on request
24 ±10%
Max. switching frequency Hz 1
Connection G1/8, G1/4 G1/8, G1/4
Power rating at UN VA 3.1 (230V) 3.3 (24V)
(W) 3.0 (110V)
2.5 (24V)
Max. power at UN (2 VA 2.9 (230V) 3.0 (24V)
(W) 2.8 (110V)
2.4 (24V)
Electrical protection IP IP65 (applise only to solenoid with cable)
Connection Cable – cable lengths see Order Instructions
103
3/2 Way Valves Electrically actuated – Type: S9 381RF-1/4-NC SO
Series S9
G1/4
Actuation systems:
– Electrical pilot operated
Versions:
– Version to ATEX Standard
5,5 x 3 flat
mounting dimensions
to NAMUR standard
* Manual override
** Solenoid width = 30 mm on low wattage coil version
X = 15,5 mm
The delivery includes:
1 Valve
2 Mounting Screws
1 Coding pin For more information on valves to ATEX standards
2 O-Rings see page 46, 47, 107
Dimensions in mm
104
Electrically actuated – Type: S9 581..-1/8 SO
5/2 Way Valves
Series S9
G1/8, G1/4
10,5 *
M5
Actuation systems:
ca. 140
14
33,5 – Electrical pilot operated
128
19,5
2
5,
22
28
5
ca. 208
4 Versions:
87,5
18
12
1
16
2
G1/8
3
4
5,5 x 3
32
flat
15,5
12
mounting
dimensions
to NAMUR standard
*
56
* Manual override
** Solenoid width = 30 mm
15,5
only for type on low wattage coil
40
S9 581-1/8SO 22** version
63
**
22
Cable length
see Order Instructions
Solenoid width 30 mm
*
M5
10
14
41
ca. 159
ca. 231
9
3
5,5 x 3
32,7
30,5
148
5,2 5
flat
4
22
106
12
20,7
1
G1/4
24
2 X = 15,5 mm
19,5
3
1 Valve
mounting
32 For more information on 2 Mounting Screws
dimensions 21
12
valves to ATEX standards 1 Coding pin
to NAMUR standard
see page 46, 47, 107 2 O-Rings
20
*
62
Dimensions in mm
105
5/3 Way Valves Electrically actuated – Type: S9 581RF.-1/8-NC SO
Series S9
G1/8, G1/4
Actuation systems:
Versions:
– With NAMUR connections
5,5 x 3 flat
– Version to ATEX Standard
mounting
dimensions
to NAMUR
standard
* Manual override
** Solenoid width = 30 mm
on low wattage coil
version
Cable length
see
Solenoid width 30 mm Order Instructions
5,5 x 3 flat
The delivery includes:
1 Ventil mounting
dimensions to
2 Mounting Screws
NAMUR standard
1 Coding pin
2 O-Rings For more information on
* Manual override
** Solenoid width = 30 mm
on low wattage coil
version
Dimensions in mm
106
Order Instructions – 3/2, 5/2 and 5/3 Way Valves – with NAMUR connections
Actuation System Symbol Order Instructions Page
Type Order No.
Electrical, 2
12 10
permanent signal S9 381RF-1/4NG SO-.. PD 33854-..33 104
1 3
Electrical, 4 2
S9 581RF-1/8 SO-.. PD 34143-..33 105
permanent signal 14 12
S9 581RF-1/4 SO-.. PD 34985-..33 105
5 13
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Standard version 230V 50/60Hz 110 V = 61 –
24V = 60V 50/60Hz 02 –
Low wattage version 24V = 13 –
230V 50/60Hz 69 –
EX Area versions to ATEX Standard
Category, type of ignition protection
Single valve: II 2G c T4 T135°C -10°C≤Ta≤+60°C
Solenoid/individual use: II 2G EEx m II T5 -20°C≤Ta≤+50°C
Solenoid/manifold mounting: II 2G EEx m II T5 -20°C≤Ta≤+40°C
Solenoid version Nominal voltage Applicable for Key code ATEX Type additon
Solenoid 24V = 48 Atex
– with cable 1.2 m
– with cable 3 m 24V = 45 Atex
– with cable 5 m 24V = 46 Atex
– with cable 10 m 24V = 47 Atex
– with cable 1.2 m 24V 50/60Hz 99 Atex
– with cable 1.2 m 110V 50/60Hz 97 Atex
– with cable 1.2 m 230V 50/60Hz 98 Atex
Example for valves in ATEX-Version:
– for valves Series S9-G1/8, S9-G1/4, S9-G1/2
Please add behind the standard order No. “ATEX“
Type: S9 581RFG-1/8SO-4633
Order No. PA34143-4633ATEX
107
5/2 Way Valve Characteristics – Pneumatically actuated with 2 hand operation and Time Delay Valve
Characteristics Symbol Unit Description
Series S9 Version Two Hand Operation Time Delay
Valve
G1/8, G1/4 Type S9 563/65RF- S9 563/65RF- S9 361RF-
1/8-SO 1/4-SO 1/8-SO
Actuation System: General Features
– Pneumatic Type Spool valve Spool valve Spool valve
for two hand operation
Mounting 2 Screws M5 2 Screws M6 2 Screws M5
2 hand operated valve for
pneumatically controlled ma- Tube connection Thread Thread Thread
chines and equipment. Port size G1/8 G1/4 (12.1 and G1/8
The 2-handed trip valves 12.2: G1/8)
PD37173 and PD37673 are Weight (mass) kg 0.27 0.64 0.18
classed as category 1 in accor-
Installation In any position
dance with
DIN EN 954-1 Ambient temperature Tmin/max °C -10 to +60 **
(only in connection with sui- range
table push button valves) and Medium temperature Tmin/max °C -10 to +60 **
type IIIA in accordance with range
DIN EN 574.
Medium Filtered compressed air - free from water and dirt to
ISO 13851: ISO 8573-1
Safety of machines; two-han- Solids: Class 6 particle <5µm for Gas
ded controls. gaswater content: pressure dew point +3°C, Class 4,
but at least 5°C less than min. operating temperature
ISO 13849-1: Lubrication * none or oil mist lubrication
Safety of machines; safety-
related parts of control Pneumatic Characteristics
systems. Nominal pressure pn bar 6
Area of application: Operating pressure range pmin/max bar 0 – 10 2-10
The 2-handed safety valves Nominal flow QN l/min 500 1300 450
are intended to be used where
persons carry out manual Actuation
control functions in areas that Pneumatic Direct
are subject to accident risks.
These comprise primarily Actuation pressure range pst min/max 2 – 10 3 – 10 2-10
equipment with pneumatic * We recommend the use of mineral oil type VG 32 to ISO 3448
cylinders, the operation of ** Note: Please consult us for operating temperatures below 0° C
which requires that both
hands are kept away from the
danger zone. The valves can Function: Fitting Instructions:
also be used to prevent unin- The valve only switches from If due to mechanical stopping We recommend the following
outlet port 4 to outlet port 2 and re-opening of the compressed time-delay valve from our range:
tended starts of pneumatic
if both signal inlets are si- air supply both control buttons type PD49078.
processes.
multaneously actuated or are are operated or possibly blocked As push button valve we recom-
actuated within 0.5 s. at the same time, the 2-handed mend the basic valve PA10307
When the operator releases trip valve will continue the control for control panel configuration,
one or both control buttons, function. The 2-handed trip in combination with push button
the valve switches back valve is not suited to prevent the KX9357.
immediately. switching from port 4 to port 2
upon the compressed air being Characteristics of time-delay
In order to resume the switch switched back on after it was shut valve see table above.
function, both trip signals off and/or permanently operated
have to be cancelled first. control buttons.
In order to prevent this process
Note: from happening, we advise users
Not applicable for operating that it is necessary to install a
eccentric presses and presses time-delay valve in the supply
of similar design. line of one of the control buttons
(line 12.1 or 12.2).
Dimensions in mm
108
Safety switch diagram (example) In order to comply with
Usage of 2-hand-operation valve with cecessary time delay valve safety requirements, plant
and equipment with certain
operating mechanisms require
the installation of a time-
delay valve in the pneumatic
control system, as shown in
the example.
Time delay valve
Type S9361RF-1/8-SO PD49078
Dimensions in mm
109
Time-delay valve to 2-handed trip valve
Type: S9 361RF-1/8-SO
Note:
Suitable measures must be
taken to protect the valves
against ingress of dust and
water.
Order Instructions
Actuation System Symbol Order Instructions
Type Order No.
pneumatic, 4 2
S9 563/65RF-1/8-SO PD37673
by 2-hand tripping
12.1
≥1 t &
S9 563/65RF-1/4-SO PD37173
12.2
5 1 3
110
Characteristics
5/2-Way
Characteristics Symbol Unit Description
General Features Oscillating
Type Spool valve Valves
Mounting
Tube connection
2 Screws M6 (M4)
Thread
Series S9
Connection size G1/4, 11 deep
G1/4
Weight (mass) kg 0.65
Installation In any position Actuation System:
Ambient temperature Tmin/max °C -10 to +60 – Pneumatic
range **
Medium Tmin/max °C -10 to +60 The oscillating valve generates
temperature range ** oscillating movements such
as e.g. shaking, hammering,
Medium Filtered and oiled or plunging, feed motions etc.
filtered, unoiled compressed air
Lubrication * None or oil mist lubrication Function:
Pneumatic Characteristics If compressed air is intro-
ducesed into inlet port 1,
Nominal pressure pn bar 6 the outlet ports 4 and 2 are
Operating pressure range pmin/max bar 3–8 alternately supplied with
compressed air.
Nominal flow QN l/min 1300
The speed of the operated
Actuation cylinder and also the stroke
Pneumatic Direct frequency are adjusted with
two exhaust air throttles.
Actuation pressure range pst min/max 3–8
* We recommend the use of mineral oil type VG 32 to ISO 3448
** Note: Please consult us for operating temperatures below 0° C
Dimensions in mm
111
Order Instructions
Actuation System Symbol Order Instructions
Type Order No.
Pneumatic S9 568/68-1/4-SO PD 34796
Dimensions in mm
112
Characteristics
3/2 and
Characteristics Symbol Unit Description
General Features 5/2 Way Valves
Type Poppet Valve Pedal actuated
Mounting
Tube connection
4 Screws M8 (1
Thread
Series F
Port size G1/4
G1/4
Weight (mass) kg 1.5
Installation In any position Actuation System:
Ambient temperature Tmin/max °C -10 to +55 – Pedal
range (3
Medium temperature Tmin/max °C -10 to +60 Connections for
range (3 3/2 way version:
Medium Filtered and oiled or filtered, Version
unoiled compressed air „Normally closed“: P, B, S
„Normally open“: P, A, R
Lubrication (2 Oil mist lubrication compatible with Buna N
Pneumatic Characteristics * Only for version “both
Nominal pressure pn bar 6 switch positions indexed“
– return is only effected
Operating pressure range pmin/max bar 0 – 10 after actuating the locking
Nominal flow QN l/min 1400 pedal.
Actuation Mounting Instruction:
Manual control Direct Use only screw connections
Stroke mm 2 with max. wrench size across
flats of 15.
Actuation force Fb N ca. 30
(1 After removing the rubber footing Connection designation:
(2 We recommend the use of mineral oil type VG 32 to ISO 3448 A = 4 Outlet
(3 Note: Please consult us for operating temperatures below 0° C B = 2 Outlet
R = 5 Exhaust
P = 1 Air supply
S = 3 Exhaust
Actuation stroke
Dimensions in mm
113
Order Instructions – 3/2 and 5/2 Way Valves
Actuation Symbol Order Instructions
Type Order No.
Pedal a
B
b
F 331RF-08NG* KZ 4410
with spring return a b
P S
A F 331RF-08NO* KZ 4411
a b
a b
P R
Pedal a,b
B F 331-08NG* KZ 4408
without reset a b
P S
a,b
A F 331-08NO* KZ 4409
a b
P R
A B
Pedal a b F 531RF-08 KZ 4413
with spring return a b
R PS
Pedal a,b
A B
F 531-08 KZ 4412
both switch positions a b
indexed
RPS
Dimensions in mm
114
Characteristics
Characteristics Symbol Unit Description
2/2 Way
General Features Stop Valves
Description 2/2 Way Valve Series ARKV
Type Poppet valve normally closed
Mounting Direct in piping G1/2 to G2
Tube connection Thread
Port size G1/2 G3/4 G1 G1 1/2 G2 Actuation System:
– Pneumatic
Weight (mass) kg 0.745 1.115 1.365 2.695 4.290
Installation In any position
Ambient temperature Tmin/max °C -20 to Note: Please consult us for operating
range +80 temperatures below 0° C
Medium temperature Tmin/max °C 0 to +80
range
Medium Compressed air, neutral gases, presswater
(for low flow- und valve closingspeed only )
Actuating medium filtered compressed air
Pneumatic characteristics
Nominal pressure pn bar 6.3
Operating pressure range pmin/max bar 0 – 10
Nominal flow QN l/min 2200 5000 6900 22000 40000
Actuation
Pneumatic Direct
115
Pneumatically actuated – Type: ARKV-..
Dimension Table
Type A B C D E F G H
ARKV-15 NC 65 G1/2 G1/8 55 61 41.5 95 109.5
ARKV-20 NC 76 G3/4 G1/4 65 75 50 112 129
ARKV-25 NC 91 G1 G1/4 65 75 57 119 139
ARKV-40 NC 123 G11/2 G1/4 110 112 67 137 167.5
ARKV-50 NC 150 G2 G1/4 130 134 75 153 190
Order Instructions
Actuation System Symbol Order data
Type Order No.
Pneumatic ARKV-15 NC PD 07334
ARKV-20 NC PD 07580
ARKV-25 NC PD 07581
ARKV-40 NC PD 07757
ARKV-50 NC PD 07765
Dimensions in mm
116
Contents
Version Actuation Standard / Page
Way Valves to
Size Characteristics Dimension Order VDMA 24563
Table Instructions
Overview and
5/2 and 5/3
Way Valves
Pneumatic
Electrical
VDMA
24563
118, 119 120 124, 125
ISO5599
Series S20 size 01
5/2 and 5/3 Pneumatic ISO 5599 118, 119 121 124, 125
Way Valves Electrical size 1 Series S20
Series S20
5/2 and 5/3 Pneumatic ISO 5599 118, 119 122 124, 125
Way Valves Electrical size 2
Series S20
5/2 and 5/3 Pneumatic ISO 5599 118, 119 123 124, 125
Way Valves Electrical size 3
Series S20
X. ..
A XD
I S OM
db y
ce
repla
i l l be
w
117
Way Valves to Characteristics
Characteristics Symbol Unit Series S20
VDMA 24563 to VDMA 01
and ISO5599 Actuation
General Features
Pneumatic Electrical
w i l l
– with external pilot air pmin. / max. bar – -0.9 – 10
Maximum flow Q max. l/min 1050 1050
Actuation
Pneumatic Direct –
Actuation pressure range
– permanent signal version pmin. / max. bar 2 – 10 2 – 10
– impulse version pmin. / max. bar 2 – 10 2 – 10
Electrical Pilot operated
Voltage type AC 50/60Hz Direct current
Nominal voltage
– Standard version Un V 230 ±10% 24 ±10%
– Low wattage version Un V – –
Initial power consumption
– Standard version VA (W) 2 2 Nominal Power
– Low wattage version VA (W) 2 2
Continuous consumption
(1 Note: – Standard version VA (W) – –
Please consult us for – Low wattage version VA (W) – –
operating temperatures Duty cycle ED % 100
below 0° C
Electrical protection IP IP65 to DIN 40050
(2 16 bar Version for
(applise only to solenoid with connector)
valves to ISO 5599
size 1, 2, 3 on request Connection Plug to
(4 Low wattage version DIN EN 175301-803 form C
connector DIN EN
175301-803 form A
118
Series S20 to ISO 5599
Size 1 Size 2 Size 3
Pneumatic Electrical Pneumatic Electrical Pneumatic Electrical
Ceramic-Spool valve
via base plate to ISO5599
Base plate
G1/4 (Base plate) G3/8 (Base plate) G1/2 (Base plate)
-10 to +60 -10 to +60 -10 to +60 -10 to +60 -10 to +60 -10 to +60
e–d
b
a c
epl -0.9 – 12
-0.9 – 12 2 – 12 -0.9 12 2 – 12 -0.9 – 12 2 – 12
-0.9 – 12 2 – 12
be r 2 – 12 -0.9 – 12 2 – 12
–
w i l l
-1 – 12 – -1 – 12 – -1 – 12
1680 1680 4320 4320 6540 6540
2 – 12 2 – 10 2 – 12 2 – 10 2 – 12 2 – 10
2 – 12 2 – 10 2 – 12 2 – 10 2 – 12 2 – 10
Pilot operated
Alternating current 50/60Hz Direct current
11 4.8
7.8 2.7
8.5 4.8
4.9 2.7
100
IP65 to DIN 40050
(applise only to solenoid with connector)
Plug to DIN EN 175301-803 form B – industrial standard (4
119
5/2 and 5/3 Weight (mass) kg
Description Type Weight * Type supplements for
Way Valves (mass) version with middle position
G = middle position closed
Series S20 Pneumatic, by permanent signal S20 561R..-01*
Pneumatic, by impulse S20 561-01
0.130
0.130
E = middle position exhausted
B = middle position pressurized
Electrical, by permanent signal S20 581R..-01* 0.170
to VDMA 24563
Electrical, by permanent signal S20 581S-R..-01* 0.170
Size 01
Electrical, by impulse S20 581-01 0.210
Actuation systems: – with biased position S20 582-01 0.210
– Pneumatic Electrical, by impulse S20 581S-01 0.210
– Electrical pilot operated
..
X.
XD
A
OM
I S
db y
ce
repla
i l l be
w
Electrical pilot operated – Type: S20 581...-01-.., S20 582...-01-.., S20 581S...-01-..
1 Gasket
* Manual override
Dimensions in mm
120
Weight (mass) kg
Description Type Weight (mass) * Type supplements for
5/2 and 5/3
Pneumatic, by permanent signal S20 561R..-1* 0.350 version with middle position Way Walves
Pneumatic, by impulse S20 561-1 0.350 G = middle position closed
E = middle position exhausted
Series S20
Electrical, by permanent signal S20 581R..-1* 0.410
B = middle position pressurized
Electrical, by permanent signal S20 581S-R..-1* 0.410 to ISO 5599
Electrical, by impulse S20 581-1 0.450 size 1
– with biased position S20 582-1 0.450
Electrical, by impulse S20 581S-1 0.450 Actuation systems:
– Pneumatic
– Electrical pilot operated
Pneumatically actuated – Type: S20 561...-1
Versions:
– With external pilot air
– With biased position
– Low wattage version
X. ..
XD
A
I S OM
db y
ce
epla
be r
will
Electrical pilot operated
Type: S20 581...-1-.., S20 582-1-.., S20 581S...-1-..
Magnet for low wattage
version
Solenoid width = 30 mm
1 Gasket
* Manual override
Dimensions in mm
121
5/2 and 5/3 Weight (mass) kg
Description Type Weight * Type supplements for
Way Valves (mass) version with middle
position
Series S20 Pneumatic, by permanent signal S20 561R..-2*
Pneumatic, by impulse S20 561-2
0.600
0.600 G = middle position
Electrical, by permanent signal S20 581R..-2* 0.650 closed
to ISO 5599 E = middle position
Electrical, by permanent signal S20 581S-R..-2* 0.650
size 2 exhausted
Electrical, by impulse S20 581-2 0.700 B = middle position
pressurized
Actuation systems: – with biased position S20 582-2 0.700
– Pneumatic Electrical, by impulse S20 581S-2 0.700
– Electrical pilot operated
X. ..
A XD
S OM
y I
ce db
er epla
i l l b
Electrical pilotw
operated Magnet for low wattage
Type: S20 581...-2-.., S20 582-2-.., S20 581S...-2-.. version
Solenoid width = 30 mm
1 Gasket
* Manual override
Dimensions in mm
122
Weight (mass) kg
Description Type Weight * Type supplements for
5/2 and 5/3
(mass) version with middle position Way Valves
Pneumatic, by permanent signal S20 561R..-3* 1.100 G = middle position
closed
Series S20
Pneumatic, by impulse S20 561-3 1.100
E = middle position
Electrical, by permanent signal S20 581R..-3* 1.150 exhausted to ISO 5599
Electrical, by permanent signal S20 581S-R..-3* 1.150 B = middle position size 3
Electrical, by impulse S20 581-3 1.200 pressurized
X. ..
A XD
I S OM
db y
ce
er epla
i l l b
woperated
Electrical pilot – Type: S20 581...-3-.. Magnet for low wattage version
Solenoid width = 30 mm
* Manual override
Dimensions in mm
123
Order Instructions – 5/2 Way Valves
Actuation Symbol Standard / Size Order Instructions Page
Type Order No.
Pneumatic VDMA 24563 Gr. 01 S20 561RF-01 PA 12891 120
by permanent signal, 14
4 2
12 ISO 5599 Größe1 S20 561RF-1 PA 12869 121
spring return
513
ISO 5599 size 2 S20 561RF-2 PA 16425 122
ISO 5599 size 3 S20 561RF-3 PA 16426 123
Pneumatic VDMA 24563 Gr. 01 S20 561R-01 PA 12892 120
by permanent signal, 14
4 2
12 ISO 5599 size 1 S20 561R-1 PA 12870 121
air spring return
ISO 5599 size 2 S20 561R-2 PA 16428 122
513
ISO 5599 size 3 S20 561R-3 PA 16429 123
Pneumatic VDMA 24563 Gr. 01 S20 561-01 PA 12893 120
by impulse 14
4 2
12 ISO 5599 size 1 S20 561-1 PA 12868 121
513
ISO 5599 size 2 S20 561-2 PA 16422 122
ISO 5599 size 3 S20 561-3 PA 16423 123
Pneumatic VDMA 24563 Gr. 01 S20 562-01 PA 12908 120
by impulse 14
4 2
12 ISO 5599 size 1 S20 562-1 PA 12905 121
with biased position
513
ISO 5599 size 2 S20 562-2
..
PA 12906
X.
122
ISO 5599 size 3 S20 562-3
MA XD
PA 12907 123
Electrical VDMA 24563 Gr. 01
O
S20 581RF-01-..
IS
PA 12886-..33 120
by permanent signal,
spring return
14
4 2
12 ISO 5599 size 1
d b y
S20 581RF-1-.. PA 12875-..33 121
pla ce
ISO 5599 size 2 S20 581RF-2-.. PA 16441-..33 122
e
5 13
b e r
ISO 5599 size 3 S20 581RF-3-.. PA 16442-..33 123
124
Order Instructions – 5/3 Way Valves
Actuation Symbol Standard / Size Order Instructions Page
Type Order No.
Pneumatic VDMA 24563 Gr. 01 S20 561RFG-01 PA 12894 120
by permanent signal, 4 2
ISO 5599 size 1 S20 561RFG-1 PA 12871 121
14 12
spring return
to middle position 51 3
ISO 5599 size 2 S20 561RFG-2 PA 16431 122
ISO 5599 size 3 S20 561RFG-3 PA 16432 123
4 2
14 12 ISO 5599 size 1 S20 561RFB-1 PA 12873 121
5 13 ISO 5599 size 2 S20 561RFB-2 PA 16437 122
513
ISO 5599 size 2 S20 561RFE-2 PA 16434 122
ISO 5599 size 3 S20 561RFE-3 PA 16435 123
Electrical VDMA 24563 Gr. 01 S20 581RFG-01 PA 12889-..33 120
by permanent signal, 4 2
ISO 5599 size 1 S20 581RFG-1-.. PA 12877-..33 121
14 12
spring return
to middle position 51 3
ISO 5599 size 2
.. S20 581RFG-2-..
3X. S20 581RFG-3-..
PA 16447-..33 122
D
AX
ISO 5599 size PA 16448-..33 123
O M
14
4 2
by
12 IS ISO 5599 size 1 S20 581RFB-1-.. PA 12879-..33 121
b e
will 14
4 2
12
VDMA 24563 Gr. 01
ISO 5599 size 1
S20 581RFE-01
S20 581RFE-1-..
PA 12890-..33
PA 12878-..33
120
121
513
ISO 5599 size 2 S20 581RFE-2-.. PA 16450-..33 122
ISO 5599 size 3 S20 581RFE-3-.. PA 16451-..33 123
with external pilot air VDMA 24563 Gr. 01 S20 581S-RFG-01.. PA 12900-..33 120
4 2
12
14
ISO 5599 size 1 S20 581S-RFG-1-.. PA 12883-..33 121
pst 513 pst ISO 5599 size 2 S20 581S-RFG-2-.. PA 16457-..33 122
ISO 5599 size 3 S20 581S-RFG-3-.. PA 16463-..33 123
4 2
14 12 ISO 5599 size 1 S20 581S-RFB-1-.. PA 12885-..33 121
pst 513 pst
ISO 5599 size 2 S20 581S-RFB-2-.. PA 16459-..33 122
pst pst
ISO 5599 size 2 S20 581S-RFE-2-.. PA 16458..33 122
513
ISO 5599 size 3 S20 581S-RFE-3-.. PA 16464..33 123
125
126
Contents
Version Standard / Size Page
Single Base
Dimensions Order Instructions Plates
Overview
Single Base Plates VDMA 24563 128 128 – to VDMA 24563,
G1/8, G1/4 size 01
Modules for Base Plate VDMA 24563 129 129
Size 01
Combimations size 01 – to ISO 5599
G1/8, G1/4
Size 1, 2, 3
Single Base Plates ISO 5599 130. 131 130. 131
size 1, 2, 3
Base Plate combinations ISO 5599 132, 133 132, 133
size 1, 2, 3
X. ..
A XD
I S OM
db y
ce
repla
i l l be
w
127
Single Base Single Base Plates Form A – Connection size G1/8 – Type: S20-01-1/8-A
Plates
to VDMA 24563
Port Size:
G1/8
G1/4
X. ..
XD
A
I
Single Base Plates Form A – Connection size G1/4 – Type: S20-01-1/4-A
S OM
db y
ce
epla
be r
w i l l
Order Instructions
Description Port size Weight (kg) Order Instructions
Type Order No.
Single Base Plate G1/8 0.070 S20-01-1/8-A KL8004
G1/4 0.120 S20-01-1/4-A KL8005
Dimensions in mm
128
End Plate Set Form D for Intermediate Plate
Description Size Weight Order Instructions Figure
Modules for
(kg) Type Order No. Base Plate
End Plate set
Form D
VDMA
01
0.220 S20-01-D KL8008 Combinations
to VDMA 24563
size 01
The delivery includes: End Plate set, completely with screws Modules:
– End Plate set, Form D, for
Intermediate Plate Form C
– Angle base plate, Form E,
for Intermediate Plate
Intermediate Plate Form C Form C
Description Port Weight Order Instructions Figure – Accessories
(Port size) (kg) Type Order No. Port Size:
G1/8
Intermediate VDMA 01 0.080 S20-01-C KL8006 G1/4
Plate form C (G1/8)
Dimensions in mm
129
Base Plates Single Base Plates Form A – Type: S9-.-A
to ISO 5599
Size 1, 2, 3
Versions:
– Single Base Plates
to VDMA 24345 Form A
X. ..
XD
A
OM
y I S
ce db
epla
be r
w i l l
ISO-Size J K L M N O P Q
1 48 5,5 110 10.5 23,5 24 G1/8 58
2 57 6,6 124 14 30 30 G1/8 74
3 71 6,6 149 17 22 32 G1/8 90
130
Single Base Plates Form B – Type: S9 -.-B
Base Plates
to ISO 5599
Size 1, 2, 3
Versions:
– Single Base Plates
to VDMA 24345 Form B
X. ..
AXD
I S OM
dby
ce
epla
be r
w i l l
ISO-Size K L M N O P Q
1 5,5 98 23 46 62 23 7.5
2 6,6 112 28 56 73 27 7.5
3 6,6 136 34 68 90 35 10
131
Modules for End Plate Set Form D for Intermediate Plate – Order Instructions and Weight
ISO-Size Weight (kg) Order Instructions Figure
Base Plate Type Order No.
Combinations 1 0.210 S9-1-D KX 9078
Versions The delivery includes: End Plate Set, completely with screws
to VDMA 24345
– End Plate set, Form D, for
Intermediate Plate, Form C
– Intermediate Plate, Form C Intermediate Plate Form C – Order Instructions and Weight
– Angle Base Plates
ISO-Size Weight (kg) Order Instructions Figure
Form E for for Intermediate
Plate Form C Type Order No.
– Accessories
1 0.240 S9-1-C KX 9079
X...
3 0.700 S9-3-C KX 9420
D
M AX and screws
The delivery includes: Intermediate Plate, completely with O-rings
IS O
b y
l a c ed
re p
Angle Base Plate Form E for Intermediate Plate Form C
Dimension Table ll be
wi
Figure
Dimensions in mm
132
Adapter Plate for Linkage of ISO-Sizes 1, 2, 3 – Dimension Table and Order Instructions
Order Instructions for ISO A B Width Figure
Type Order No. Size
S9-1-3-KP KX 9432 1 to 3 35 190 50
S9-1-BP KX 9082 1 12 70 40
S9-2-BP KX 9423 2 12 90 55
A XD
OM
The delivery includes: Dummy Plate with gasket and screws
y I S
ce db
er
Plug – Order Instructions epla
l l b
wi Order No.
Order Instructions for ISO Size Figure
Type
S9-1-VS KX 5789 1
S9-2-VS KX 9426 2
S9-3-VS KX 9427 3
Dimensions in mm
133
Connection- Example of Plate Combination
ISO-Size 3
X...
Adapter Plate
A XD
ISO-Size 1
I S OM
db y
lace
Angle Base Plate Form E
134
Ordering Code
neutral
Channel divider
channel divider
Input module
Ident-No. Valve position
Connection
Number of
Position of
Electrical
inputs
Valves
1 2 3 4 5 6 7 8 9 10 11 12
04 06 08 10 12
even number of valve positions only
Important: Please specify the code for
the desired valve types
Input Modules
K X. ..
X DS
Pins IP20
Valve Islands – Sizes
M A Plug M8 IP65
PA 10381 Type: IM20-1/8
y ISO 04-08-12 Number of inputs
Connections:
ced b 16-20-24
pla
G1/8: valve outlets 28-32
G1/4: base plate
e r e
b
will
PA12867 Type: IM20-1/4
Connections:
Dual Pressure Operating
J with channel divider
G1/4: valve outlets
in Connection 1 (P)
G3/8: base plate
01 – 11 Position
of channel divider
Electrical Connection to valve position
Multipol-Version
DS with sub-D-conn. Ordering Code for Valves and Cover Plates
HI with industrial Code Symbol Description
connector A – Blanking plate on valve position
Valves M 14
4 2
12
5/2 way solenoid valve,
permanent signal with spring
04 to 4 valves return Type: S9 581RF-..
5 13
06 5 and 6 valves
J 4 2
12
5/2 way solenoid valve,
08 7 and 8 valves 14
impulse
Type: S9 581RF-..
10 9 and 10 valves 513
135
136
Information on application
The contents of this catalog are not binding and are only intended for infor- Importance of EU Directives
mational purposes and are not to be considered as offer with legal effect. A
written confirmation of order from Parker Origa is authoritative for the con- Various Directives have been issued by the EU Commission in the course of
clusion of a contract; this confirmation is given solely under the respective the unification of the single European market; the following Directives are in
currently applicable Parker Origa General Terms of Sale and Delivery. These part of significance for ORIGA products:
are included in our price list and in the Internet at www.parker-origa.com. – Simple pressure vessels (87/404/EWG, amended by 90/488/EWG and
93/68/EWG)
All the products presented in this catalog are purely for commercial use. – Low-voltage electrical equipment (73/23/EWG, amended by 93/68/EWG)
None of the information or contents is appropriate for private consumers. – Machinery Directive (89/392/EWG, amended by 91/368/EWG, 93/44/
Private consumers cannot place orders based on the information in the EWG and 98/37/EG)
catalog. Please contact Parker Origa for further information. – Pressure Equipment Directive (97/23/EWG)
– Equipment and protective systems intended for use in potentially
All the products listed in this catalog are designed for typical pneumatic explosive atmospheres (ATEX Directive, 94/9/EG)
applications which e.g. are installed in higher-level machines. The reco- – Electromagnetic Compatibility Directive (EMV Directive, 89/336/EWG,
gnized technical rules for safe and expert work are to be observed for the use amended by 92/31/EWG)
and installation of pneumatic products. The precondition for the use of the
products is, unless stated otherwise, correctly prepared compressed air free If a product comes within the scope of application of one of these Guideli-
from aggressive media. Furthermore, the respective regulations of the legis- nes, then an EU Declaration of Conformity with CE mark (CE for Commun-
lator, the TÜV (Technical Inspection Association), the respective professional auté Européenne) is required. This CE marking does not represent a quality
associations or the VDE (Association of Electrical, Electronic and Information feature but verifies that the conformity assessment procedure specified has
Technologies) provisions also apply. been concluded successfully and the protective requirements of the relevant
EU Directives have been observed.
The technical data stated in this catalog is to be observed by the user. The
data stated may not be exceeded nor fallen short of. If such data is not Products which do not come under any of the above mentioned Directives
stated then it may be assumed that there are no such upper or lower limits may not bear the CE mark nor may any manufacturer’s declaration according
or restrictions for particular applications. In the case of unusual physical or to the EU Machinery Directive or Declaration of Conformity be issued for
chemical applications, consultation and clearances are to be obtained from these products.
Parker Origa
If a product may not be CE marked according to the Machinery Directive, it
Unless otherwise agreed in individual cases, the customer or end consumer must however be marked if it comes within the scope of application of any
is responsible for the disposal of the ORIGA products. Disposal by Parker other Directive.
Origa is not included in the price and this would have to be taken into ac- The following harmonized standards are applied in the design of ORIGA
count in the event of any applicable return to and disposal by Parker Origa. components and systems:
Technical data and representations – DIN EN ISO 12100 Safety of machinery
– DIN EN 60204.1 Electrical equipment of machines
The technical data and illustrations have been compiled with great care and
– DIN EN 983 Safety requirements for fluid power systems and their
to the best of our knowledge. We cannot assume any guarantee for the up-to-
components
dateness, correctness and completeness of the information.
The following Directives are of particular significance to Parker Origa:
The data and information such as illustrations, drawings, descriptions,
dimensions, weights, materials, technical and other performances as well as – ORIGA products in potentially explosive atmospheres, to which the above
the products and services described in general product descriptions, Parker mentioned ATEX Directive applies, are treated according to the Directive
Origa catalogs, brochures and price lists of any type are subject to change and CE and EX marked.
and may be modified or updated at any time without prior announcement – According to the Machinery Directive, ORIGA products are mainly
by Parker Origa. They are only binding in so far as the contract or confirma- components for installation in machines and therefore do not require an
tion of order expressly refers to them. Slight deviations from such product EU Declaration of Conformity with CE mark. Parker-ORIGA issues
descriptions are deemed as approved and do not affect the fulfillment of a manufacturer’s declaration according to the Machinery Directive for
contracts in so far as these are considered acceptable to customers. these components. This declaration corresponds to a great extent to
the Declaration of Conformity with the comment that commissioning is
This catalog does not contain any guarantees, assured characteristics or ag- only permitted if the machine or system conforms to the Directives. This
reements on condition by Parker Origa for the products represented, neither manufacturer’s declaration impacts neither our product liability based on
expressly nor implicitly, nor with regard to the availability of the products. the product liability law nor warranty assurances according to our General
Advertising statements regarding quality characteristics, properties or appli- Terms of Sale and Delivery. Neither does the manufacturer’s declaration
cations of ORIGA products are without legal obligation. affect our quality assurance measures according to our Quality
Management Manual nor our quality certification according to ISO 9001.
As far as legally permissible, any liability is excluded on the part of Parker – According to the Pressure Equipment Directive, ORIGA products are
Origa for direct or indirect damage, consequential damage, claims of any components of low hazard potential, thus most of the products do not
type and on any legal basis arising from the use of the information contained come under this Directive. The exceptions to this are maintenance
in this catalog. equipment from a certain pressure/volume level onwards. These
components are treated according to the Directive if required and bear the
Trademarks, copyright and reproduction CE mark.
The representation of industrial rights such as brands, logos, registered
trademarks or patents in this catalog does not include the granting of ORIGA products are excluded from the following EU Guidelines:
licenses or rights of use. The use of these is not permitted without the – End-of-life vehicles (2000/53/EG).
express consent of Parker Origa. The entire contents of this catalog are the – Waste Electronic and Electrical equipment (WEEE, 2002/96/EG) and
intellectual property of Parker Origa. Within the meaning of copyright, any Restriction on Hazardous Substances (RoHS, 2002/95/EG).
unlawful use of intellectual property, even extracts, is prohibited. Reprinting, – Pressure Equipment Directive (97/23/EWG) with the above mentioned
reproduction and translation (even extracts) are only permitted with the prior exceptions.
written consent of Parker Origa.
Parker Worldwide
Parker-Origa GmbH
Industriestr. 8
70794 Filderstadt, Deutschland
Tel. +49 (0)7158 17030
Fax +49 (0)7158 64870
Email: [email protected]