Tarasafe International Pvt. Ltd.
Budge Budge Trunk Road, P.O. Govindapur,
P.S.Maheshtala
IN-700141 Kolkata
Att: *Mr. Naveen Shinghari
REPORT ISSUED BY THE RESEARCH ASSOCIATION OF THE TEXTILE
INDUSTRY, AITEX
Nº 2015ID0086
1/20
The test was carried out at :High Current Laboratory located at Polígono
Industrial Fuente del Jarro. C/ Ciudad de Gibraltar, 5; 46988 – Paterna
(Valencia); which property is shared at 50% between research institutes
AITEX and ITE.
Test report Nº2015ID0086
Applicant Tarasafe International Pvt. Ltd.
Budge Budge Trunk Road, P.O. Govindapur, P.S.Maheshtala
IN-700141 Kolkata
Date of Date Test
02/01/2014 Starting: 09/01/2014
reception
Ending: 30/01/2014
Description and identification of samples
- “FABRIC 94109”
Sample description:
Yellow woven fabric, style 94109, fiber content: 49% modacrylic, 41,5% cotton, 5% para-aramid, 4%
polyamide, 0,5% antistatic fiber, with an approximated weight of 250 g/m2, according information supplied
by the customer.
Test Carried out
- ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV OR
EBT50) OF FLAME RESISTANT MATERIAL CLOTHING
2/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV OR EBT50) OF
FLAME RESISTANT MATERIAL CLOTHING
Test results
The test program includes minimum of twenty individual panel arc trials.
The following test data was recorded for each trial:
Arc exposure electrical conditions: arc trial number, RMS arc current, peak arc current, arc voltage, arc
duration, energy dissipated in arc, plots of arc current and arc voltage.
Temperature rise response from two monitor sensors for each panel in each trial, plot of average responses
from two monitor sensors.
Pictures after arc exposure.
Video.
Essential test data and test results are presented in the following pages as follows:
Arc rating: ATPV or EBT50 or both and plots of the burn injury probability (ATPV) or break open probability
(EBT50) or both versus Ei.
Heat attenuation factor (HAF) and plot of HAF on Ei.
Test specimen description and order of layer.
Distance from an arc center line to the panel surface.
Subjective evaluation.
Pictures after arc exposure.
Ignition probability value (if determined during testing).
__________________________________________________________________>>>
3/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Standard
ASTM F1959 / F1959M – 12
Test conditions
Date test. 30/01/2014
Arc current (8 ± 1) kA
Stainless steel electrodes, gap of the electrodes (300 ± 5) mm
Distance between the electrodes and sample (300 ± 5) mm
Fuse wire 0.5 mm
Number of samples tested 21
Starting and ending pre-treatment date 09/01/2014 - 09/01/2014
Starting and ending conditioning date 29/01/2014 - 30/01/2014
Conditioning 24 h; 21 ± 1ºC, 65 ± 2 % Hr.
__________________________________________________________________>>>
4/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Reference FABRIC 94109
Sample type
Yellow woven fabric, style 94109, fiber content: 49% modacrylic, 41,5% cotton, 5% para-aramid, 4%
polyamide, 0,5% antistatic fiber, with an approximated weight of 250 g/m2, according information supplied by
the customer.
Pre-treatment
3 washing cycles at 49ºC, according to standard AATCC 135:2012, method 3IV and type Aiii drying
Washed sample weight before test
267,8 g/m2
Deviation from the standard
---
__________________________________________________________________>>>
5/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Determination of ATPV, 50% of Probability of 2nd degree burn
ATPV: 11,8 cal/cm2
Probability % 5 10 20 30 40 50 60 70 80 90
Ei cal/cm2 11,8 11,8 11,8 11,8 11,8 11,8 11,8 11,8 11,8 11,8
ATPV points above 13
ATPV points 20% 11
ATPV points below 8
ATPV points mix zone 0
__________________________________________________________________>>>
6/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Determination of HAF, confidence Intervals 95%
HAF: 81,6 %
% HAF value : 81,6
Upper Confidence Level %: 82,5
Lower Confidence Level %: 80,7
Points above: 8
Points below: 6
Points between: 7
Total Points: 21
__________________________________________________________________>>>
7/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Summary of measured energy and subjective evaluation:
Test Time Cycles Ei SCD HAF Burn Break Open
(ms) 50Hz cal/cm2 cal/cm2 %
1-A 223,8 11,19 13,6 0,31 83,9 Y N
1-B 223,8 11,19 10,1 -0,19 82,1 N N
1-C 223,8 11,19 11,4 -0,12 84,1 N N
2-A 303,2 15,16 18,0 1,38 82,6 Y N
2-B 303,2 15,16 14,7 0,73 81,5 Y N
2-C 303,2 15,16 14,7 0,61 82,6 Y N
3-A 143,6 7,18 7,6 -0,5 82,9 N N
3-B 143,6 7,18 5,9 -0,46 77,3 N N
3-C 143,6 7,18 6,2 -0,47 81,3 N N
4-A 243,6 12,18 11,7 -0,1 83,9 N N
4-B 243,6 12,18 11,8 0,63 78,8 Y N
4-C 243,6 12,18 12,4 0,41 81,0 Y N
5-A 273,4 13,67 16,9 1,16 82,5 Y N
5-B 273,4 13,67 15,4 1,49 78,4 Y N
5-C 273,4 13,67 12,6 0,21 82,3 Y N
6-A 223,4 11,17 13,0 0,55 80,6 Y N
6-B 223,4 11,17 12,9 0,63 79,8 Y N
6-C 223,4 11,17 12,0 0,53 79,0 Y N
7-A 203,6 10,18 10,8 -0,19 84,1 N N
7-B 203,6 10,18 14,2 0,52 83,0 Y N
7-C 203,6 10,18 9,0 -0,24 82,3 N N
__________________________________________________________________>>>
8/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Summary of measured energy and subjective evaluation:
Test After flame Ablation Melting Dripping Charring Embrittlement
1-A 0,4 N N N Y Y
1-B N N N N Y Y
1-C N N N N Y Y
2-A 0,5 N N N Y Y
2-B 0,3 N N N Y Y
2-C 0,2 N N N Y Y
3-A N N N N Y N
3-B N N N N Y N
3-C N N N N Y N
4-A N N N N Y Y
4-B N N N N Y Y
4-C N N N N Y Y
5-A 0,5 N N N Y Y
5-B N N N N Y Y
5-C N N N N Y Y
6-A N N N N Y Y
6-B N N N N Y Y
6-C N N N N Y Y
7-A N N N N Y Y
7-B N N N N Y Y
7-C N N N N Y Y
Y Yes N No
__________________________________________________________________>>>
9/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Calibration shot
INITIAL CALIBRATION
Ei Panel A 7,4 cal/cm2 Ei Panel B 6,6 cal/cm2 Ei Panel C 7,1 cal/cm2
FINAL CALIBRATION
Ei Panel A 8,2 cal/cm2 Ei Panel B 9,1 cal/cm2 Ei Panel C 8,3 cal/cm2
__________________________________________________________________>>>
10/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 1
Current Total RMS (kA) 8,0 Current Peak (kA) 17,8 Arc Voltage (V) 1521,0
Duration (cycles nº) 11,2 Duration (ms) 223,7 Arc Energy (kJ) 708,7
sensor response PANEL A PANEL B PANEL C
Ei 13,63 cal/cm2 10,07 cal/cm2 11,40 cal/cm2
SCD 0,31 cal/cm2 -0,19 cal/cm2 -0,12 cal/cm2
HAF 83,91 % 82,12 % 84,09 %
__________________________________________________________________>>>
11/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 2
Current Total RMS (kA) 8,0 Current Peak (kA) 17,6 Arc Voltage (V) 1521,0
Duration (cycles nº) 15,2 Duration (ms) 303,2 Arc Energy (kJ) 991,4
sensor response PANEL A PANEL B PANEL C
Ei 17,98 cal/cm2 14,73 cal/cm2 14,74 cal/cm2
SCD 1,38 cal/cm2 0,73 cal/cm2 0,61 cal/cm2
HAF 82,61 % 81,54 % 82,58 %
__________________________________________________________________>>>
12/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 3
Current Total RMS (kA) 8,2 Current Peak (kA) 17,4 Arc Voltage (V) 1521,0
Duration (cycles nº) 7,2 Duration (ms) 143,5 Arc Energy (kJ) 476,7
sensor response PANEL A PANEL B PANEL C
Ei 7,61 cal/cm2 5,86 cal/cm2 6,24 cal/cm2
SCD -0,50 cal/cm2 -0,46 cal/cm2 -0,47 cal/cm2
HAF 82,86 % 77,29 % 81,32 %
__________________________________________________________________>>>
13/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 4
Current Total RMS (kA) 8,0 Current Peak (kA) 17,3 Arc Voltage (V) 1524,0
Duration (cycles nº) 12,2 Duration (ms) 243,6 Arc Energy (kJ) 769,4
sensor response PANEL A PANEL B PANEL C
Ei 11,72 cal/cm2 11,81 cal/cm2 12,36 cal/cm2
SCD -0,10 cal/cm2 0,63 cal/cm2 0,41 cal/cm2
HAF 83,88 % 78,77 % 81,02 %
__________________________________________________________________>>>
14/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 5
Current Total RMS (kA) 8,0 Current Peak (kA) 17,5 Arc Voltage (V) 1518,0
Duration (cycles nº) 13,7 Duration (ms) 273,4 Arc Energy (kJ) 895,8
sensor response PANEL A PANEL B PANEL C
Ei 16,89 cal/cm2 15,41 cal/cm2 12,64 cal/cm2
SCD 1,16 cal/cm2 1,49 cal/cm2 0,21 cal/cm2
HAF 82,47 % 78,40 % 82,33 %
__________________________________________________________________>>>
15/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 6
Current Total RMS (kA) 8,1 Current Peak (kA) 17,6 Arc Voltage (V) 1524,0
Duration (cycles nº) 11,2 Duration (ms) 223,4 Arc Energy (kJ) 737,2
Sensor response PANEL A PANEL B PANEL C
Ei 12,97 cal/cm2 12,90 cal/cm2 11,97 cal/cm2
SCD 0,55 cal/cm2 0,63 cal/cm2 0,53 cal/cm2
HAF 80,61 % 79,78 % 78,95 %
__________________________________________________________________>>>
16/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Electrical current and response sensor response:
Shot 7
Current Total RMS (kA) 8,1 Current Peak (kA) 17,8 Arc Voltage (V) 1524,0
Duration (cycles nº) 10,2 Duration (ms) 203,6 Arc Energy (kJ) 652,7
sensor response PANEL A PANEL B PANEL C
Ei 10,82 cal/cm2 14,23 cal/cm2 9,04 cal/cm2
SCD -0,19 cal/cm2 0,52 cal/cm2 -0,24 cal/cm2
HAF 84,12 % 83,02 % 82,33 %
__________________________________________________________________>>>
17/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Tested material pictures:
Original Shot 1 Shot 2
Shot 3 Shot 4 Shot 5
Shot 6 Shot 7
__________________________________________________________________>>>
18/20
TEST REPORT Nº 2015ID0086
RESULTS
ELECTRIC ARC EXPOSURE TEST: DETERMINATION OF THE ARC RATING (ATPV or EBT50) OF FLAME RESISTANT
MATERIAL CLOTHING
Summary of results:
ATPV 11,8 cal/cm2
HAF 81,6 %
FABRIC TESTED ACCORDING TO THE STANDARD ASTM F1959 / F1959M - 12 FULFILLING
THE REQUIREMENTS OF STANDARD ASTM F1506-10a.
ARC RATING
12,0 cal/cm2
NOTE
*According to ASTM F1506, arc rating values below 10 cal/cm2 shall be reported to the nearest 0.1 cal/cm2,
and arc rating values above 10 cal/cm2 shall be reported to the nearest 1 cal/cm2.
__________________________________________________________________///
19/20
TEST REPORT Nº 2015ID0086
Lucia Martinez
Head of PPE´s department
Digitally signed by LUIS MIRALLES
ESTEVE - NIF:21684919J
Date: 2015.07.22 18:21:40 CEST
Reason:
Location: Alcoy
LIABILITY CLAUSES
1. AITEX is liable only for the results of the methods of analysis used, as
expressed in the report and referring exclusively to the materials or samples
indicated in the same which are in its possession, the professional and legal
liability of the Centre being limited to these. Unless otherwise stated, the
samples were freely chosen and sent by the applicant.
2. AITEX shall not be liable in any case of misuse of the test materials nor for
undue interpretation or use of this document
3. The original test report is kept in AITEX. An electronic copy of it is
delivered to the costumer which keeps the value from the original one as far
as the security properties of the document are not violated. A hard copy of
this report with the AITEX logotype sealed in all the pages, keeps the original
value.
4. The results are considered to be the property of the applicant, and AITEX
will not communicate them to third parties without prior permission. After
one month, AITEX may use the results for statistical or scientific purposes.
5. None of the indications made in this report may be considered as being a
guarantee for the trade marks mentioned herein.
6. In the eventuality of discrepancies between reports, a check to settle the
same will be carried out in the head offices of AITEX. Also, the applicants
undertake to notify AITEX of any complaint received by them as a result of
the report, exempting this Centre from all liability if such is not done, the
periods of conservation of the samples being taken into account.
7. AITEX may include in its reports, analyses, results, etc., any other
evaluation which it considers necessary, even when it has not been
specifically requested.
8. If not are included, the estimated uncertainties in the tests accredited by
ENAC are at the client' s disposal in AITEX.
9. The tested samples will be stored in AITEX facilities during the next
TWELVE MONTHS after the report emission. Any verification or complaint,
requested by the client, will be made during the mentioned period.
10. This report may only be sent or delivered by hand to the applicant or to a
person duly authorised by the same.
11. The test results and the fulfillment declaration with the specification of
this test report refers only to the test specimen in the conditions that it has
been tested and not to the sample/item from where this specimen has been
extracted
Laboratorios: Delegaciones comerciales:
ASOCIACION DE INVESTIGACION DE LA INDUSTRIA TEXTIL, AITEX Atlanta (USA)
Plaza Emilio Sala, 1 y C/Sant Jordi, 13 Bogotá (Colombia)
E-03801 ALCOY (Alicante) SPAIN Dhaka (Bangladesh)
Tel. +34 965542200 Kaunas (Lituania)
Fax. +34 965543494 Karachi y Faisalabad (Pakistán)
CIF G03182870 New Delhi (India)
São Paulo (Brasil)
www.aitex.es Shanghai (China)
www.observatoriotextil.com
[email protected] 20/20