20-OCT-2023 56312E39

RYLR993

868/915MHz LoRaWAN® & Proprietary Dual Mode Transceiver Module

Datasheet

13mm*13mm*2.2mm
RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

PRODUCT DESCRIPTION
The RYLR993 868/915MHz LoRaWAN® Transceiver Module feature the LoRa long range modem that
provides ultra-long range spread spectrum communication and high interference immunity whilst
minimising current consumption.

FEATURES
• ST STM32WLE5CCU6 256KB flash Industrial LoRa® SOC Engine.
• Customized firmware design service is available.
• AT Command over UART interface
• High sensitivity.
• Temperature sensor.
• Low power consumption.
• AES128 CCM Data encryption
• LoRaWAN® class A, B & C support
• LoRaWAN® and LoRa® Proprietary selection.
• Support bands : US915, EU868, AS923, IN865, KR920, RU864
• Support REYAX RYLR998 proprietary mode

APPLICATIONS
• IoT Applications
• Mobile Equipment
• Home Security
• Industrial Monitoring and Control Equipment
• Car Alarm

CERTIFICATION
• CE RED
• FCC
• MIC Japan
• NCC

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 2


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

PIN DESCRIPTION

U1

44

43

42

41

40

39

38

37

36

35

34

33
REY AX RY LR993

PA3

PA2

PA1

PA0

PB8

PB7

PB6

PB5
GND

RF

GND

GND
1 32
GND GND
2 31
PA6 PB3
3 30
PA7 PB4
4 29
PA8 PA15
5 28
PA9 GND
6 27
PH3 PA14/JTCK-SWCLK
7 26
GND NRST
8 25
GND PC13
9 24
GND PA13/JTMS-SWDIO
10 23
GND GND
VBAT

PB12

PA10

PA11

PA12
GND

GND
VDD

VDD

VDD

PB0

PB2
11

12

13

14

15

16

17

18

19

20

21

22

Pin Name I/O Condition


1 GND - Ground
2 PA6 I/O Not Connected, Reserved for future applications
3 PA7 I/O Not Connected, Reserved for future applications
4 PA8 I/O Not Connected, Reserved for future applications
5 PA9 I/O Not Connected, Reserved for future applications
6 PH3 I Add a 10KΩ resistor between GND and PH3.
7 GND - Ground
8 GND - Ground
9 GND - Ground
10 GND - Ground
11 GND - Ground
12 VBAT I The RTC and the backup registers power supply
13 VDD I VDD, VDDA, VDDPA Power supply
14 VDD I VDD, VDDA, VDDPA Power supply
15 VDD I VDD, VDDA, VDDPA Power supply
16 PB0 I/O Not Connected, Reserved for future applications
17 PB2 I/O Not Connected, Reserved for future applications

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 3


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

18 PB12 I/O Not Connected, Reserved for future applications


19 PA10 O RF_RX_ACTIVE Indicator, When data is received,
This pin will output high for 500 ms.
20 PA11 O RF_TX_ACTIVE Indicator, When data is
transmitted, This pin will output high for 500 ms.
21 PA12 O LoRaWAN Link indicator, When the RYLR993 not
connect to LoRa gateway, This pin will output Hi
500ms and Low 500ms continuously.
22 GND - Ground
23 GND - Ground
24 PA13/JTMS-SWDIO I/O Not Connected, Reserved for future applications
25 PC13 I/O Not Connected, Reserved for future applications
26 NRST I Low reset trigger input
27 PA14/JTCK-SWCLK I/O Not Connected, Reserved for future applications
28 GND - Ground
29 PA15 I/O Not Connected, Reserved for future applications
30 PB4 I/O Not Connected, Reserved for future applications
31 PB3 I/O Not Connected, Reserved for future applications
32 GND - Ground
33 PB5 I/O Not Connected, Reserved for future applications
34 PB6 I/O Not Connected, Reserved for future applications
35 PB7 I/O Not Connected, Reserved for future applications
36 PB8 I/O Not Connected, Reserved for future applications
37 PA0 I/O Not Connected, Reserved for future applications
38 PA1 I/O Not Connected, Reserved for future applications
39 PA2/TXD O UART Data Output
40 PA3/RXD I UART Data Input
41 GND - Ground
42 GND - Ground
43 RF I/O RF Input/Output
44 GND - Ground

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 4


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

TIMING DIAGRAM

VDD

RST

TXD Keep Low before power on Keep Low before power off

RXD Keep Low before power on Keep Low before power off

POWER ON TX/RX POWER OFF

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 5


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

BLOCK DIAGRAM

Processor RYLR993
RF Switch
TX : PA4=H, PA5=L
RX : PA4=L, PA5=H

Filter Match
Schematic

RFO RFIN
STM32WLE5CCU6
LoRa® SOC Engine
15uH
VLXSMPS
VDDRF1V55
470nF
VFBSMPS PA4
PA5
NRESET
VBAT
TXD VBAT Power Supply
VDD
RXD
VDDA VDD
OSC_IN VDDPA Power Supply

32.768KHz & 32MHz Temperature sensor


Crystal

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 6


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

SPECIFICATION
Item Min. Typical Max. Unit Condition
VDD Power Supply 3 3.3 3.6 V
VBAT Power Supply 2.7 3.3 3.6 V
Frequency Accuracy ±10 ppm at 25°C ±3°C

RF Output Power Range -4 20 22 dBm


RF Harmonic -36 dBm
RF sensitivity -148 dBm
RF Input Level 10 dBm
Filter insertion loss 1 2 3 dB
Frequency Range 820 868/915 960 MHz
Transmit Current 140 mA RFOP = +22 dBm
Class A Current 5 uA
Class B & C Current 5 mA
Sleep mode 2 uA Proprietary AT+MODE=1
Baud rate 9600 bps 8, N, 1
Temperature sensor 2
°C
Accuracy
Voltage detector 2 % AT+BAT
Accuracy
Digital input level high 0.8 VDD V VIH
Digital input level low 0.2 V VIL
Digital output level high 0.9 V VOH Imax = 1 mA
Digital output level low 0.1 V VOL Imax = -1 mA
Operating Temperature -40 25 +85 ˚C
Dimensions 13mm*13mm*2.2mm
Weight 0.71 g

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 7


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

TRANSMIT POWER CONSUMPTION TEST

(PROPRIETARY MODE)
AT+CRFOP (dBm) Typical Current (mA) VDD=3.3V
0 44.9
1 47.6
2 51.4
3 54.0
4 58.4
5 61.2
6 64.7
7 68.8
8 72.9
9 77.2
10 81.5
11 85.9
12 91.1
13 97.1
14 102.5
15 107.5
16 111.8
17 115.5
18 119.5
19 123.2
20 126.9
21 130.0
22 135.5

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 8


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

BAND PASS FILTER TEST

Condition :

1. Center frequency : 923MHz

2. SF9, Bandwidth 125KHz, Coding Rate 4/5, Programmed Preamble 12.

50

0
922.88 922.9 922.92 922.94 922.96 922.98 923 923.02 923.04 923.06 923.08 923.1

-50
Attenuation(dB)

-100

-150

-200

-250
Frequency(MHz)

*Avoid using center frequencies that are 4MHz apart as this may cause crosstalk issues due to IF
demodulation.

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 9


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

APPLICATION SCHEMATIC

CON1 E1
HIROSE U.FL-R-SMT-1 REY AX RY AF915
CON2
NC
1 VDD

TXD 2 PA13/JTMS-SWDIO

PA14/JTCK-SWCLK
RXD

3
RF

4 NRST

5
U1
44

43

42

41

40

39

38

37

36

35

34

33
REY AX RY LR993
PA3

PA2

PA1

PA0

PB8

PB7

PB6

PB5
RF
GND

GND

GND

VDD

5
1 32
GND GND CON3
2 31 90 degree 6 pin
PA6 PB3

NRST

RXD

TXD
3 30
PA7 PB4
4 29
PA8 PA15 C1 C2 C3 C4
5 28 47uF 0603 47uF 0603 0.1uF 100pF
R10 10K PA9 GND
6 27 PA14/JTCK-SWCLK B1
PH3 PA14/JTCK-SWCLK SKQGADE010
7 26 NRST
GND NRST
8 25
GND PC13
9 24 PA13/JTMS-SWDIO
GND PA13/JTMS-SWDIO VDD
10 23
GND GND

LED1 VDD
RED 0805
VBAT

PB12

PA10

PA11

PA12
GND

GND
VDD

VDD

VDD

PB0

PB2

LED2 VDD
GREEN 0805
11

12

13

14

15

16

17

18

19

20

21

22

R4
1K
LED3
BLUE 0805
R5 R6
1K Q1 1K
LINK AO3418

R3 0 R7 R8
VBAT 1K Q2 1K
RF_TX_ACTIVE AO3418

R9
VDD 1K Q3
RF_RX_ACTIVE AO3418

R2
NC
VDD

R1
NC

Title
RYLR993_Lite
Size Document Number Rev
Custom<Doc> 1.2

Date: Tuesday , August 09, 2022 Sheet 1 of 1

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 10


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

REFLOW SOLDERING
Consider the "IPC-7530 Guidelines for temperature profiling for mass soldering (reflow and wave) processes, published 2001. Only
single reflow soldering processes are recommended for REYAX modules. Repeated reflow soldering processes and soldering the
module upside down are not recommended.

Preheat phase
Initial heating of component leads and balls. Residual humidity will be dried out. Please note that this preheat phase will not replace
prior baking procedures.
• Temperature rise rate: max. 3 °C/s If the temperature rise is too rapid in the preheat phase it may cause excessive slumping.
• Time: 60 - 120 s If the preheat is insufficient, rather large solder balls tend to be generated.
Conversely, if performed excessively, fine balls and large balls will be generated in clusters.
• End Temperature: 150 - 200 °C If the temperature is too low, non-melting tends to be caused in
areas containing large heat capacity.

Heating/ Reflow phase


The temperature rises above the liquidus temperature of 217°C. Avoid a sudden rise in temperature as the slump of the paste could
become worse.
• Limit time above 217 °C liquidus temperature: 40 - 60 s
• Peak reflow temperature: 245 °C

Cooling phase
A controlled cooling avoids negative metallurgical effects (solder becomes more brittle) of the solder and possible mechanical
tensions in the products. Controlled cooling helps to achieve bright solder fillets with a good shape and low contact angle.
• Temperature fall rate: max 4 °C/s To avoid falling off, the REYAX module should be placed on the topside of the motherboard
during soldering.

[°C] Y值
Preheat Heating Cooling
250 Peak Temp245°C
Liquidus temperature
217
200
40-60s Max 4°C/s

150
End Temp Typical Leadfree
Soldering Profile
Max 3°C/s 150-200°C

100 Y值

50
60-120s

0
0 50 100 150 200 250 300
座標軸標題
Elapsed Time

Recommended soldering profile

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 11


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

CERTIFICATIONS

ETSI EN 300 220-1 V3.1.1 (2017-02)

ETSI EN 300 220-2 V3.2.1 (2018-06)

• FCC Statement:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment.

LABEL OF THE END PRODUCT:


The final end product must be labeled in a visible area with the following " Contains TX FCC ID : QLY-RYLR993 ". If the size of the end
product is larger than 8x10cm, then the following FCC part 15.19 statement has to also be available on the label: This device complies
with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference
and (2) this device must accept any interference received, including interference that may cause undesired operation.

QLYRYLR993

• MIC Japan compliance

020-230271

上記のとおり、電波法第 38 条の 24 第 1 項の規定による特定無線設備の工事設計についての認証を行ったものであるこ

とを証する。

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 12


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

• Taiwan NCC Statement 低功率電波輻射性電機管理辦法:

第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設
計之特性及功能。

第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾
時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、
科學及醫療用電波輻射性電機設備之干擾。

CCAK23Y10110T4

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 13


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

DIMENSIONS

Unit : mm

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 14


RYLR993
868/915MHz LoRaWAN®& Proprietary Dual Mode Transceiver Module

LAYOUT FOOTPRINT RECOMMENDATIONS

Unit : mm

E-mail : [email protected]
Website : http://reyax.com

Copyright © 2022, REYAX TECHNOLOGY CO., LTD. 15