Chemosil® 211 Primer and/or Adhesive
Technical Data Sheet
Chemosil® 211 primer is a heat-activated material For further detailed information on surface preparation
designed for use as a substrate primer under other of specific substrates, refer to Chemlok/Chemosil
Chemosil covercoat adhesives, or as a one-coat Adhesives application guide.
adhesive for bonding unvulcanized nitrile elastomer
Mixing – Thoroughly stir primer before use, and agitate
compounds. It is composed of a mixture of polymers,
sufficiently during use to keep dispersed solids uniformly
organic compounds and mineral fillers dissolved or
suspended. If dilution is needed, use ketone-type
dispersed in an organic solvent system.
solvents such as MEK and MIBK. Note proper dilution
of various application methods is best achieved by
Features and Benefits: experience. Give careful attention to agitation since
dilution will accelerate settling.
Versatile – can be used as a primer under a wide variety
of Chemosil covercoat adhesives. Applying – Apply primer by brush, roll coat, dip or spray
methods. Avoid applying thick coats which result in
Convenient – can be used as a one-coat adhesive to
poor drying and may lead to film displacement during
bond unvulcanized nitrile elastomer compounds to metal
molding.
and plastics.
Regardless of application method, the dry film thickness
Easy to Apply – applies easily by spray, dip, brush or
of Chemosil 211 primer should be 8-12 micron (0.3-
roll coat methods.
0.5 mil).
Durable – provides high tear and cohesive strength, as
Drying/Curing – Thoroughly dry parts coated with
well as excellent environmental resistance when used in
Chemosil 211 primer before applying the covercoat
combination with Chemosil covercoat adhesives.
adhesive. This will take at least 30 minutes at room
temperature. Drying time can be shortened by using hot
Elastomers: air drying ovens or tunnels up to 90°C (194°F).
• Nitrile (NBR) Cleanup – Use MIBK or MEK for clean up.
Application: Shelf Life/Storage:
Surface Preparation – Thoroughly clean metal Shelf life is one year from date of manufacture when
surfaces prior to application. Remove protective oils, stored by the recipient below 25°C (77°F) in original,
cutting oils and greases by solvent degreasing or unopened container.
alkaline cleaning. Remove rust, scale or oxide coatings
by suitable chemical or mechanical cleaning methods.
Typical Properties*
Appearance Grey Liquid
Viscosity, cps @ 25°C (77°F) 90 - 170
Brookfield LVT
Spindle 2, 30 rpm
Density @ 20°C (68°F)
g/cm3 0.92 - 0.96
(lb/gal) (7.7 - 8.0)
Solids Content by Weight, % 22 - 26
Dry residue, 30 minutes @ 130°C (266°F)
Flash Point, °C (°F) 17 (62)
Pensky-Martens
Solvents MIBK, Xylene
*Data is typical and not to be used for specification purposes.
Chemosil 211 Primer and/or Adhesive — Technical Data Sheet
Cautionary Information:
Before using this or any Parker Lord product, refer to
the Safety Data Sheet (SDS) and label for safe use and
handling instructions.
For industrial/commercial use only. Must be applied by
trained personnel only. Not to be used in household
applications. Not for consumer use.
Values stated in this document represent typical values as not all tests are run on each lot of material produced. For formalized product specifications for specific product end uses, contact the Customer Support Center.
Information provided herein is based upon tests believed to be reliable. In as much as Parker Lord has no control over the manner in which others may use this information, it does not guarantee the results to be obtained. In addition,
Parker Lord does not guarantee the performance of the product or the results obtained from the use of the product or this information where the product has been repackaged by any third party, including but not limited to any
product end-user. Nor does the company make any express or implied warranty of merchantability or fitness for a particular purpose concerning the effects or results of such use.
WARNING — USER RESPONSIBILITY. FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the
application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided
from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and
specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
©2022 Parker Hannifin - All Rights Reserved Information and specifications subject to change without OD DS3901E 12/22 Rev.3
notice and without liability therefor. Trademarks used herein
are the property of their respective owners.
Parker Lord Lord Suisse Sàrl
Engineered Materials Group A Parker Hannifin Company
111 LORD Drive La Tuilière 6
Cary, NC 27511-7923 1163 Etoy
USA Switzerland
www.Parker.com/EPM phone +41 (0) 21 821 85 00