ALL CHANGES OR ADDITIONAL WORK MUST BE APPROVED BY THE HDLC

DEMOLITION NOTES-ARCHITECTURAL

1050 south norman c francis parkway, suite 241


COMMON ST.
SPRINKLER D1 DEMOLISH AND REMOVE EXISTING INTERIOR PARTITION FULL
RISER HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE, DATA,
BASE, CHAIR RAIL, PILASTERS, VISION PANELS, PIPING,
CLEAN-OUTS, ETC.

NON-STRUCTURAL D2 REMOVE EXISTING DOOR, FRAME AND CASING. RETURN FIRST


FLOOR DOORS TO OWNER STOCK FOR POSSIBLE RE-USE.

new orleans, louisiana 70125


D6
D6

terrell-fabacher
UP D6

architects, l.l.c.
D3 DEMOLISH AND REMOVE EXISTING CASEWORK, PLATFORM
INTERIOR WORK ONLY. ELEVATOR D2 SHELVING, COUNTER ETC. IN ITS ENTIRETY. PROTECT

INTERIOR DEMOLITION NOT EXTERIOR WORK OR CHANGES ARE D11 LOBBY


D10
D1 ADJOINING SURFACES TO REMAIN FROM DAMAGE.

BEAM
D4 DEMOLISH AND REMOVE EXISTING PANELLED KNEE WALL AND
APPROVED UNDER THIS APPLICATION. ALL CAP.
D1 OFFICE

504 566 1320


EXTERIOR WORK REQUIRES SEPARATE
218 ST. CHARLES AVE. & 632 COMMON ST. APPLICATION AND HDLC APPROVAL. D11 STOR.
OFFICE
D5 DEMOLISH AND REMOVE EXISTING TOILET ROOM PARTITIONS
AND ASSOCIATED FASTENERS.

D2 D10
NEW ORLEANS, LOUISIANA 70130 D1
D2 D10 D6 DEMOLISH AND REMOVE EXISTING WALL FURRING OR FINISH
FULL HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE,
DATA, BASE, WAINSCOT, CHAIR RAIL, ETC.
Removal of exterior fire

BEAM
escapes approved separately UP
D1
D7 DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
DUCTWORK, AND ASSOCIATED MATERIALS.
under #23-30021-HDLC D2 D1
SCOPE OF WORK: ELEC. CORRIDOR
D8 REMOVE SUSPENDED CEILING SYSTEMS, ACOUSTICAL,
D2 GYP. BD. AND PLASTER TO EXPOSE THE CEILING JOIST AND
INTERIOR DEMOLITION OF NON-STRUCTURAL PARTITIONS STEEL BEAMS. THIS INCLUDES THE DEMOLITION OF LIGHT
AND MEP SYSTEMS OF EXISTING 4-STORY COMMERCIAL D10 ADJOINING FIXTURES, INSULATION, ABANDONED BUILDING COMPONENTS
BUILDING IN PREPARATION FOR CONVERSION TO A D3 VACANT BUILDING (I.E. -DUCTS, REGISTERS, CONDUITS, PIPING, WIRING,
HOTEL TO BE PERMITTED SEPARATELY. D3 634 COMMON ST. FASTENERS ETC.). THIS INCLUDES ALL CEILINGS ON ALL
ADJOINING BUILDING
D1 D4 COPY (NOT A PART) FLOORS.

D4 D10 D6
TOTAL AREA CALCULATIONS: 200 ST. CHARLES AVE.
(NOT A PART) D1
D9 DEMOLISH AND REMOVE ALL DAMAGED WOOD STRIP FLOORING
AND SUB FLOOR. FLOORING/DECKING IN GOOD CONDITION ARE
OFFICE TO REMAIN.
FIRST FLOOR 5,594 SQ. FT.
SECOND FLOOR 4500 SQ. FT.
D1
D10 DEMOLISH AND REMOVE ALL EXISTING VINYL TILE AND MASTIC,
D10

BEAM
THIRD FLOOR

project (will) (will not) be visited


These plans and specifications
4500 SQ. FT.

requirements to the best of my


CARPET, PADS NAILING STRIPS, CERAMIC TILE AND THIN SET

have been prepared by me or


FOURTH FLOOR 4500 SQ. FT. DOWN TO THE EXISTING CONCRETE OR WOOD DECKING.

under my close supervision.


D2 OPEN

knowledge and belief. The


TOTAL BUILDING AREA OFFICE D1 D11 DEMOLISH AND REMOVE CLAY TILE AT ELEVATOR SHAFT.

periodically to review job


19,094 SQ. FT.

They comply with all city


OFFICE REMOVE ELEVATOR CAB,ELEVATOR DOORS, CONTROLS,
GUIDERAILS, BRACKETS, MACHINE, CONDUITS, CABLES ETC.
INDEX OF DRAWINGS: D1 D2
D10
D6
STEEL D12 DEMOLISH AND REMOVE FIRE ESCAPE STAIRS AT THE ST.
D-1 TITLE SHEET, FIRST FLOOR DEMOLITION PLAN & NOTES COLUMN, CHARLES AVE. AND COMMON STREET FACADES. THROUGH
D-2 SECOND FLOOR DEMOLITION PLAN & NOTES TYP. WALL FASTENERS TO BE CUT BACK FLUSH WITH BUILDING
FACE.
D-3 THIRD FLOOR DEMOLITION PLAN & NOTES DEMOLITION LEGEND D6 D10 D2

progress.
D-4 FOURTH FLOOR DEMOLITION PLAN & NOTES
D-5 FIFTH FLOOR DEMOLITION PLAN & NOTES
OFFICE D10 D13 DEMOLISH AND REMOVE MECHANICAL SHED IN COURTYARD
ABOVE THE FIRST FLOOR IN ITS ENTIRETY. PROVIDE
D1 TEMPORARY COVERS AS NEEDED TO MAINTAIN WATER

BEAM
EXISTING SOLID MASONRY WALLS TO REMAIN.
D2 D1 TIGHT CONDITIONS.

D14 DEMOLISH AND REMOVE PLASTER FURRING FROM ALL


BEAMS AND COLUMNS TO EXPOSE THE CONDITION OF
EXISTING INTERIOR PARTITION TO REMAIN. D4 D10 THE STRUCTURAL MEMBERS.
D6
D1 D4 D15 REMOVE EXISTING WINDOW TO NOWHERE.
EXISTING PARTITION TO BE DEMOLISHED AND REMOVED
VE.

OFFICE D16 REMOVE COVER FROM WINDOW OPENING.


IN ITS ENTIRETY. CORRIDOR
D10
ES A

D17 DEMOLISH AND REMOVE EXISTING PLUMBING FIXTURES AND

CAMP ST. (SIDE)


D1 ASSOCIATED TRIM. REMOVE ALL WASTE AND WATER ROUGH

DEMOLITION PLANS FOR


218 ST. CHARLES AVE. &
OFFICE INS AND CAP PLUMBING BELOW SLAB.
SPRINKLER D1
L

LOUISIANA
RISER D18 DEMOLISH AND REMOVE ROOFTOP MECHANICAL
R

BEAM
AND PLUMBING EQUIPMENT. PROVIDE TEMPORARY
A

632 COMMON ST.

632 COMMON ST.


COVERS AS NEEDED TO MAINTAIN WATER TIGHT
H

D6 D2 CONDITIONS.
ST. C

D6 D6 D17 D6 D6 OPEN
D19 DEMOLISH AND REMOVE CHILLED WATER PIPING AND
OFFICE HEATING HOT WATER PIPING. REMOVE PIPING FROM
AIR HANDLER ON FIRST FLOOR, UP THROUGH SECOND
D6 FLOOR AND TRAVEL TO MECHANICAL SHED IN
D5 D17 STORM D10 COURTYARD. CAP INSIDE ADJACENT BUILDING.
DRAIN UP
D20 DEMOLISH AND REMOVE DAMAGED GUTTER SYSTEM
D10 OFFICE

NEW ORLEANS,
OFFICE
D1 D17 OPEN D6
D6 D1 OFFICE D10
MEN'S D1 OFFICE
D10 ROOM
D5 D17
D10 D10
MECHANICAL
VAULT
D1 DEMOLITION NOTES-MECHANICAL/PLUMBING
D10 BEAM
D17 D7 1. DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
DUCTWORK, AND ASSOCIATED MATERIALS.
D6
D1 D1 D4 D4
D17 D6 D1 2. DEMOLISH AND REMOVE SPRINKLER PIPING AND HEADS
D2 D2 D3 THROUGHOUT INCLUDING HANGERS AND FASTENERS.
SPRINKLER RISERS TO REMAIN.
BREAK
D1 D6 D10 D4 ELEC.
BREAK
D1 D1 D4 ROOM 3. EXISTING INCOMING DOMESTIC WATER METERS AND MAINS
ROOM D2 D2 D4 D6
BEAM BEAM OPEN INTO BUILDING SHALL REMAIN FOR FUTURE USE. ALL
OPEN D10 DOWNSTREAM PIPING SHALL BE REMOVED.
OFFICE
D3 D1 BEAM D4 OFFICE
D10 D1 STEEL D10 D1
D10 COLUMN,
4. EXISTING SEWER MAIN CONNECTIONS SHALL REMAIN FOR
D2 CORRIDOR D10 D2 FUTURE USE.
D2 TYP.
GENERAL DEMOLITION NOTES:
218 ST. CHARLES AVE. 5. REMOVE FLOOR DRAINS AND SEAL PIPE BELOW SLAB.
D2 D4 D1 PROVIDE TEMPORARY

BEAM
1. THE CONTRACTOR IS TO FIELD VERIFY ALL EXISTING CONDITIONS
CORRIDOR D10 6. REMOVE EXISTING GAS PIPING IF PRESENT.
PRIOR TO START OF DEMOLITION WORK. COVER AT OPENING IN
D1 D1 PARTY WALL.
2. IT IS THE INTENT OF DEMOLITION DRAWINGS, NOTES, AND LEGEND
TO REMOVE ALL EXISTING CONSTRUCTION AS INDICATED ON THE
DRAWINGS WHICH CONFLICTS WITH THE INTENT OF THE NEW WORK. D1
PERMANENT 3-HOUR
FIRE RESISTANCE
DEMOLITION NOTES-ELECTRICAL
3. THE CONTRACTOR IS TO COORDINATE MECHANICAL AND ELECTRICAL D10 D2 D2 RATED INFILLED TO BE 1. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO
PROVIDED BY OTHERS PROVIDE A COMPLETE DEMOLITION OF ELECTRICAL SYSTEMS
DEMOLITION, WITH ALL OTHER DEMOLITION.
D6 D1 D1 D1 CONNECTIONS TO THE ADJACENT BUILDINGS THAT MEETS THE
4. THE CONTRACTOR IS TO PROTECT EXISTING ADJACENT BUILDING
UNDER SEPARATE
CONFERENCE D2 D10 CONTRACT
REQUIREMENTS OF THE LISTED INFORMATION AND THE OWNER.
SURFACES AND FINISHES TO REMAIN. THE CONTRACTOR WILL D1 OFFICE D2 D10
REPLACE LIKE NEW EXISTING BUILDING FEATURES AND SURFACES 2. THE CONTRACTOR SHALL REMOVE ALL POWER
DAMAGED DURING THE COURSE OF BUILDING DEMOLITION AT NO
COST TO THE OWNER.
D10 OFFICE OFFICE OFFICE
CONNECTIONS TO 632 COMMON ST. AND 218 ST. CHARLES
D1 D1 FROM BUILDING 228 ST. CHARLES OR 634 COMMON ST. THIS
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL INCLUDES ANY POSSIBLE BRANCH CIRCUITS THAT CROSS
DEMOLITION DEBRIS AND DUST ON A DAILY BASIS. JOB SITE IS TO
D10 D10 BUILDING SEPARATION WALLS. POWER OUTAGE SHALL BE
BE KEPT CLEAN. COORDINATED WITH THE BUILDING OWNERS AT A TIME THAT IS
D3 D1 CONVENIENT TO THEIR SCHEDULE.
6. EXISTING MASONRY WALLS: ALL PLASTER OR OTHER FINISHED D6 D6 D6
D6 D6
MATERIALS APPLIED TO EXTERIOR MASONRY PERIMETER WALLS D6 D6 3. ALL ELECTRICAL CONDUITS, WIRES, CABLES, OR WIRE WAYS THAT NO. REVISIONS
ARE TO BE REMOVED IN THEIR ENTIRETY FOR INSPECTION OF PENETRATE THE BUILDING SEPARATION WALL SHALL BE
SOUNDNESS AND SCOPE OF REPOINTING OR REPAIR. REMOVED AND SEALED.
7. THESE DRAWINGS ARE NOT INTENDED TI INDICATE OR TO FULLY
DESCRIBE EACH ITEM TO BE REMOVED. 4. ALL SPECIAL SYSTEMS WIRING, CABLING AND CONDUITS FOR
TELEPHONE, DATA, FIRE ALARM, SECURITY ETC. THAT
8. VERIFY WITH OWNER, PRIOR TO DEMOLITION, BUILDING ITEMS THAT THE PENETRATE THE BUILDING SEPARATION WALL SHALL BE
OWNER WOULD LIKE SALVAGE FOR RE-USE. REMOVED AND SEALED.

9. STRUCTURAL ELEMENTS SUCH AS THE MASONRY WALLS, LOAD


ADJOINING VACANT BUILDING
228 ST. CHARLES AVE.
PROVIDE TEMPORARY COVER AT
OPENING IN PARTY WALL.
PERMANENT 3-HOUR FIRE
GRAVIER ST. (SIDE) FIRST FLOOR - 5,594 SQ. FT. 5. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO
BEARING WALLS, COLUMNS AND BEAMS ARE TO REMAIN. OWNER REPAIR ANY DAMAGE DONE TO THE INTEGRITY OF THESE
(NOT A PART) RESISTANCE RATED INFILLED TO SYSTEMS TO 634 COMMON ST. AND 228 SR. CHARLES. ALL
WILL CONTRACT WITH A SHORING CO. TO STABILIZE THE BUILDING
PRIOR TO DEMOLITION. BE PROVIDED BY OTHERS UNDER CONDUIT PENETRATIONS SHALL BE SEALED WITH A MATERIAL
CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT CHECKED BY:
SEPARATE CONTRACT
10. THE DEMOLITION CONTRACTOR SHALL COORDINATE AND OBTAIN GASES WHEN TESTED IN ACCORDANCE WITH ASTM-E814.
ALL NECESSARY PERMITS AND APPROVALS FROM GOVERNING DRAWN BY:
REGULATORY AGENCIES PRIOR TO PROCEEDING WITH WORK. 6. ALL EXISTING PANEL BOARD CIRCUIT DIRECTORIES TO ADJACENT
BUILDINGS SHALL BE UPDATED DENOTING "SPARE" FOR
11. THE DEMOLITION CONTRACTOR SHALL COMPLY WITH ALL BREAKERS THAT ARE NO LONGER USED. THE REMAINING
BREAKERS SHALL BE LABELED AS LISTED WITH A PREFIX "EX".
DATE:
DEMOLITION OF STRUCTURES. SAFETY AND PROTECTION OF
ADJACENT BUILDINGS AND OCCUPIED AREAS, DUST CONTROL,
UTILITY DISCOVERED HAZARDS AND DISPOSAL. 1 FIRST FLOOR DEMOLITION PLAN THE DIRECTORIES SHALL BE DATED.

7. DEMOLISH AND REMOVE ALL ELECTRICAL BOXES, SWITCHES, JOB NO.:


10/24/2023

12. THE DEMOLITION CONTRACTOR SHALL PROVIDE TEMPORARY A-1 SCALE: 3/16" = 1'-0" CONDUITS, COMMUNICATION SYSTEMS, SECURITY SYSTEMS
CONSTRUCTION MEASURES AS REQUIRED TO PROTECT CABLE AND WIRING THROUGHOUT THE PROJECT SITE.
WORKERS AND THE PUBLIC FROM INJURY AS REQUIRED BY
REGULATORY AGENCIES AND STANDARD O.S.H.A. GUIDELINES. 8. DEMOLISH AND REMOVE ROOFTOP ELECTRICAL EQUIPMENT.
PROVIDE TEMPORARY COVERS AS NEEDED TO MAINTAIN
WATER TIGHT CONDITIONS.

D-1
13. THE DEMOLITION CONTRACTOR SHALL COORDINATE ALL
TERMINATIONS/DISCONNECTIONS OF UTILITY SERVICES WITH
ENTERGY AND THE SWBNO AND OBTAIN REQUIRED
PERMITS/APPROVALS.

14. ALL EXTERIOR WINDOWS AND DOORS ARE TO REMAIN. SHEET 1 OF 5


DEMOLITION CONTRACTOR TO PROTECT WINDOWS FROM DAMAGE.
ALL CHANGES OR ADDITIONAL WORK MUST BE APPROVED BY THE HDLC

1050 south norman c francis parkway, suite 241


DEMOLITION NOTES-ARCHITECTURAL
D12
D1 DEMOLISH AND REMOVE EXISTING INTERIOR PARTITION FULL
COMMON ST. HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE, DATA,
BASE, CHAIR RAIL, PILASTERS, VISION PANELS, PIPING,
CLEAN-OUTS, ETC.

D2 REMOVE EXISTING DOOR, FRAME AND CASING. RETURN FIRST

new orleans, louisiana 70125


FLOOR DOORS TO OWNER STOCK FOR POSSIBLE RE-USE.

terrell-fabacher
architects, l.l.c.
D3 DEMOLISH AND REMOVE EXISTING CASEWORK, PLATFORM
D16 D6 SHELVING, COUNTER ETC. IN ITS ENTIRETY. PROTECT
D6 D16 ADJOINING SURFACES TO REMAIN FROM DAMAGE.
D6
D6
D4 DEMOLISH AND REMOVE EXISTING PANELLED KNEE WALL AND
D11 CAP.

504 566 1320


D6 D5 DEMOLISH AND REMOVE EXISTING TOILET ROOM PARTITIONS
D9 AND ASSOCIATED FASTENERS.

D6 DEMOLISH AND REMOVE EXISTING WALL FURRING OR FINISH


D11 FULL HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE,
DATA, BASE, WAINSCOT, CHAIR RAIL, ETC.
D2
D7 DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
DUCTWORK, AND ASSOCIATED MATERIALS.

D8 REMOVE SUSPENDED CEILING SYSTEMS, ACOUSTICAL,


UP GYP. BD. AND PLASTER TO EXPOSE THE CEILING JOIST AND
STEEL BEAMS. THIS INCLUDES THE DEMOLITION OF LIGHT
FIXTURES, INSULATION, ABANDONED BUILDING COMPONENTS
(I.E. -DUCTS, REGISTERS, CONDUITS, PIPING, WIRING,
FASTENERS ETC.). THIS INCLUDES ALL CEILINGS ON ALL
FLOORS.

D9 DEMOLISH AND REMOVE ALL DAMAGED WOOD STRIP FLOORING


D6 ADJOINING VACANT BUILDING
AND SUB FLOOR. FLOORING/DECKING IN GOOD CONDITION ARE
634 COMMON ST. TO REMAIN.
(NOT A PART)
ADJOINING BUILDING

project (will) (will not) be visited


These plans and specifications
D10 DEMOLISH AND REMOVE ALL EXISTING VINYL TILE AND MASTIC,

requirements to the best of my


200 ST. CHARLES AVE.

have been prepared by me or


CORRIDOR BEARING WALL CARPET, PADS NAILING STRIPS, CERAMIC TILE AND THIN SET

under my close supervision.


(NOT A PART) DOWN TO THE EXISTING CONCRETE OR WOOD DECKING.
FRAMING TO

knowledge and belief. The

periodically to review job


REMAIN

They comply with all city


EXIT D11 DEMOLISH AND REMOVE CLAY TILE AT ELEVATOR SHAFT.
STAIR REMOVE ELEVATOR CAB,ELEVATOR DOORS, CONTROLS,
GUIDERAILS, BRACKETS, MACHINE, CONDUITS, CABLES ETC.

D12 DEMOLISH AND REMOVE FIRE ESCAPE STAIRS AT THE ST.


STORAGE
Approved separately CHARLES AVE. AND COMMON STREET FACADES. THROUGH
under #23-30021-HDLC WALL FASTENERS TO BE CUT BACK FLUSH WITH BUILDING
FACE.

progress.
E.

D13 DEMOLISH AND REMOVE MECHANICAL SHED IN COURTYARD


ABOVE THE FIRST FLOOR IN ITS ENTIRETY. PROVIDE
AV

TEMPORARY COVERS AS NEEDED TO MAINTAIN WATER


DEMOLITION LEGEND D2
632 COMMON ST. TIGHT CONDITIONS.
RLES

DN D14 DEMOLISH AND REMOVE PLASTER FURRING FROM ALL


BEAMS AND COLUMNS TO EXPOSE THE CONDITION OF
EXISTING SOLID MASONRY WALLS TO REMAIN. D9 THE STRUCTURAL MEMBERS.
HA

D15 REMOVE EXISTING WINDOW TO NOWHERE.


At interior side only. No exterior
ST. C

work or changes are approved D16 REMOVE COVER FROM WINDOW OPENING.
EXISTING INTERIOR PARTITION TO REMAIN.
under this permit, TYP D17 DEMOLISH AND REMOVE EXISTING PLUMBING FIXTURES AND

DEMOLITION PLANS FOR


218 ST. CHARLES AVE. &
D6 ASSOCIATED TRIM. REMOVE ALL WASTE AND WATER ROUGH
EXISTING PARTITION TO BE DEMOLISHED AND REMOVED INS AND CAP PLUMBING BELOW SLAB.

LOUISIANA
IN ITS ENTIRETY.

CAMP ST. (SIDE)


D18 DEMOLISH AND REMOVE ROOFTOP MECHANICAL
D9 AND PLUMBING EQUIPMENT. PROVIDE TEMPORARY

632 COMMON ST.


COVERS AS NEEDED TO MAINTAIN WATER TIGHT
CONDITIONS.

D6 D19 DEMOLISH AND REMOVE CHILLED WATER PIPING AND


HEATING HOT WATER PIPING. REMOVE PIPING FROM
STORM AIR HANDLER ON FIRST FLOOR, UP THROUGH SECOND
D6 DRAIN D6 D15 FLOOR AND TRAVEL TO MECHANICAL SHED IN
D1 CORRIDOR D9 UP BEARING WALL COURTYARD. CAP INSIDE ADJACENT BUILDING.
D1 FRAMING TO
D20 DEMOLISH AND REMOVE DAMAGED GUTTER SYSTEM

NEW ORLEANS,
REMAIN
D2
D1 D2 D6 D19
D17 D1 D1
D2 DEMOLITION NOTES-MECHANICAL/PLUMBING
D1 D3 D1 D3 D6
D2
D6 1. DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
D1 D1 D1 DUCTWORK, AND ASSOCIATED MATERIALS.
D1
D6 D2
D1 2. DEMOLISH AND REMOVE SPRINKLER PIPING AND HEADS
THROUGHOUT INCLUDING HANGERS AND FASTENERS.
D1 D3 SPRINKLER RISERS TO REMAIN.
D4 D9
VACANT VACANT
3. EXISTING INCOMING DOMESTIC WATER METERS AND MAINS
INTO BUILDING SHALL REMAIN FOR FUTURE USE. ALL
D4 D9 D3 D1
D12 D6 D2 218 ST. CHARLES AVE. BEARING WALL
DOWNSTREAM PIPING SHALL BE REMOVED.
FIRE ESCAPE BEARING WALL
LANDING AND FRAMING TO FRAMING TO 4. EXISTING SEWER MAIN CONNECTIONS SHALL REMAIN FOR
D6 D1 D6 D6 REMAIN FUTURE USE.
GUARD RAIL TO REMAIN
REMAIN THIS D9
5. REMOVE FLOOR DRAINS AND SEAL PIPE BELOW SLAB.
FLOOR
6. REMOVE EXISTING GAS PIPING IF PRESENT.
D6 D6 D6 D1 D6 ROOF

D2 D6 DEMOLITION NOTES-ELECTRICAL
D3 D3
D6 D2 D9 D1 D1 1. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO
D1 D13 PROVIDE A COMPLETE DEMOLITION OF ELECTRICAL SYSTEMS
D2 CONNECTIONS TO THE ADJACENT BUILDINGS THAT MEETS THE
D4 D1 REQUIREMENTS OF THE LISTED INFORMATION AND THE OWNER.
D2 D1 D1 2. THE CONTRACTOR SHALL REMOVE ALL POWER
D9 D19 CONNECTIONS TO 632 COMMON ST. AND 218 ST. CHARLES
VACANT FROM BUILDING 228 ST. CHARLES OR 634 COMMON ST. THIS
D4 D2 D1 INCLUDES ANY POSSIBLE BRANCH CIRCUITS THAT CROSS
D6 BUILDING SEPARATION WALLS. POWER OUTAGE SHALL BE
D2 VACANT COORDINATED WITH THE BUILDING OWNERS AT A TIME THAT IS
D2 CONVENIENT TO THEIR SCHEDULE.
D1 D1 D2 D13
D3 MECHANICAL 3. ALL ELECTRICAL CONDUITS, WIRES, CABLES, OR WIRE WAYS THAT NO. REVISIONS
SHED PENETRATE THE BUILDING SEPARATION WALL SHALL BE
D3 REMOVED AND SEALED.
D2
D6 D6 D6 D1 D6 4. ALL SPECIAL SYSTEMS WIRING, CABLING AND CONDUITS FOR
D6 TELEPHONE, DATA, FIRE ALARM, SECURITY ETC. THAT
PENETRATE THE BUILDING SEPARATION WALL SHALL BE
REMOVED AND SEALED.

5. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO


REPAIR ANY DAMAGE DONE TO THE INTEGRITY OF THESE
SYSTEMS TO 634 COMMON ST. AND 228 SR. CHARLES. ALL
GRAVIER ST. (SIDE) CONDUIT PENETRATIONS SHALL BE SEALED WITH A MATERIAL
CHECKED BY:
ADJOINING VACANT BUILDING
228 ST. CHARLES AVE.
SECOND FLOOR - 4,500 SQ. FT. CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT
GASES WHEN TESTED IN ACCORDANCE WITH ASTM-E814.
DRAWN BY:
(NOT A PART) 6. ALL EXISTING PANEL BOARD CIRCUIT DIRECTORIES TO ADJACENT
BUILDINGS SHALL BE UPDATED DENOTING "SPARE" FOR
BREAKERS THAT ARE NO LONGER USED. THE REMAINING
DATE:
BREAKERS SHALL BE LABELED AS LISTED WITH A PREFIX "EX".
THE DIRECTORIES SHALL BE DATED.
10/24/2023

1 SECOND FLOOR DEMOLITION PLAN 7. DEMOLISH AND REMOVE ALL ELECTRICAL BOXES, SWITCHES,
CONDUITS, COMMUNICATION SYSTEMS, SECURITY SYSTEMS
CABLE AND WIRING THROUGHOUT THE PROJECT SITE.
JOB NO.:

A-1 SCALE: 3/16" = 1'-0" 8. DEMOLISH AND REMOVE ROOFTOP ELECTRICAL EQUIPMENT.
PROVIDE TEMPORARY COVERS AS NEEDED TO MAINTAIN
WATER TIGHT CONDITIONS.

D-2
SHEET 2 OF 5
ALL CHANGES OR ADDITIONAL WORK MUST BE APPROVED BY THE HDLC

D12

1050 south norman c francis parkway, suite 241


DEMOLITION NOTES-ARCHITECTURAL
D1 DEMOLISH AND REMOVE EXISTING INTERIOR PARTITION FULL
COMMON ST. HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE, DATA,
BASE, CHAIR RAIL, PILASTERS, VISION PANELS, PIPING,
CLEAN-OUTS, ETC.

new orleans, louisiana 70125


D2 REMOVE EXISTING DOOR, FRAME AND CASING. RETURN FIRST
FLOOR DOORS TO OWNER STOCK FOR POSSIBLE RE-USE.

terrell-fabacher
architects, l.l.c.
D3 DEMOLISH AND REMOVE EXISTING CASEWORK, PLATFORM
D16 D6
SHELVING, COUNTER ETC. IN ITS ENTIRETY. PROTECT
D6 D16 ADJOINING SURFACES TO REMAIN FROM DAMAGE.
D6
D6 D4 DEMOLISH AND REMOVE EXISTING PANELLED KNEE WALL AND

504 566 1320


D11 CAP.

D5 DEMOLISH AND REMOVE EXISTING TOILET ROOM PARTITIONS


D6 AND ASSOCIATED FASTENERS.
D9
STORAGE D3
D6 DEMOLISH AND REMOVE EXISTING WALL FURRING OR FINISH
D11 FULL HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE,
DATA, BASE, WAINSCOT, CHAIR RAIL, ETC.
D2 D7 DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
DUCTWORK, AND ASSOCIATED MATERIALS.

D8 REMOVE SUSPENDED CEILING SYSTEMS, ACOUSTICAL,


UP ROOF OF GYP. BD. AND PLASTER TO EXPOSE THE CEILING JOIST AND
ADJOINING VACANT BUILDING STEEL BEAMS. THIS INCLUDES THE DEMOLITION OF LIGHT
634 COMMON ST. FIXTURES, INSULATION, ABANDONED BUILDING COMPONENTS
BEARING WALL (NOT A PART) (I.E. -DUCTS, REGISTERS, CONDUITS, PIPING, WIRING,
FRAMING TO FASTENERS ETC.). THIS INCLUDES ALL CEILINGS ON ALL
REMAIN D3 FLOORS.

D9 DEMOLISH AND REMOVE ALL DAMAGED WOOD STRIP FLOORING


D6 D3 AND SUB FLOOR. FLOORING/DECKING IN GOOD CONDITION ARE
ADJOINING BUILDING TO REMAIN.

project (will) (will not) be visited


These plans and specifications

requirements to the best of my


200 ST. CHARLES AVE.

have been prepared by me or


D10 DEMOLISH AND REMOVE ALL EXISTING VINYL TILE AND MASTIC,
(NOT A PART)

under my close supervision.


CARPET, PADS NAILING STRIPS, CERAMIC TILE AND THIN SET
CORRIDOR

knowledge and belief. The


DOWN TO THE EXISTING CONCRETE OR WOOD DECKING.

periodically to review job


They comply with all city
D1 D11 DEMOLISH AND REMOVE CLAY TILE AT ELEVATOR SHAFT.
REMOVE ELEVATOR CAB,ELEVATOR DOORS, CONTROLS,
GUIDERAILS, BRACKETS, MACHINE, CONDUITS, CABLES ETC.
D3 632 COMMON ST.
D12 DEMOLISH AND REMOVE FIRE ESCAPE STAIRS AT THE ST.
Approved separately CHARLES AVE. AND COMMON STREET FACADES. THROUGH
under #23-30021-HDLC WALL FASTENERS TO BE CUT BACK FLUSH WITH BUILDING

progress.
FACE.
STORAGE D13 DEMOLISH AND REMOVE MECHANICAL SHED IN COURTYARD
ABOVE THE FIRST FLOOR IN ITS ENTIRETY. PROVIDE
TEMPORARY COVERS AS NEEDED TO MAINTAIN WATER
DEMOLITION LEGEND D3 TIGHT CONDITIONS.
D2 D9
DN
AVE.

D14 DEMOLISH AND REMOVE PLASTER FURRING FROM ALL


BEAMS AND COLUMNS TO EXPOSE THE CONDITION OF
EXISTING SOLID MASONRY WALLS TO REMAIN. D6 THE STRUCTURAL MEMBERS.
D3
S

D3 At interior side only. No exterior


D15 REMOVE EXISTING WINDOW TO NOWHERE.
LE

EXISTING INTERIOR PARTITION TO REMAIN. D5 work or changes are approved D16 REMOVE COVER FROM WINDOW OPENING.
CHAR

D17 under this permit, TYP

DEMOLITION PLANS FOR


218 ST. CHARLES AVE. &
D17 DEMOLISH AND REMOVE EXISTING PLUMBING FIXTURES AND
EXISTING PARTITION TO BE DEMOLISHED AND REMOVED D5 D9 ASSOCIATED TRIM. REMOVE ALL WASTE AND WATER ROUGH

LOUISIANA
INS AND CAP PLUMBING BELOW SLAB.
IN ITS ENTIRETY. D17 D1
ST.

D2

CAMP ST. (SIDE)


D18 DEMOLISH AND REMOVE ROOFTOP MECHANICAL

632 COMMON ST.


AND PLUMBING EQUIPMENT. PROVIDE TEMPORARY
D17 COVERS AS NEEDED TO MAINTAIN WATER TIGHT
CONDITIONS.
D17
D19 DEMOLISH AND REMOVE CHILLED WATER PIPING AND
HEATING HOT WATER PIPING. REMOVE PIPING FROM
AIR HANDLER ON FIRST FLOOR, UP THROUGH SECOND
STORM D2 STORAGE
FLOOR AND TRAVEL TO MECHANICAL SHED IN
D6 DRAIN D6 D15 COURTYARD. CAP INSIDE ADJACENT BUILDING.
D1 CORRIDOR D9 UP D2 BEARING WALL

NEW ORLEANS,
D1 FRAMING TO D20 DEMOLISH AND REMOVE DAMAGED GUTTER SYSTEM
REMAIN
D1 D2
D1 D1
D6 DEMOLITION NOTES-MECHANICAL/PLUMBING
D1 D4 D3 D1 D3 D6
1. DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
D1 D1 D1 VACANT D6 DUCTWORK, AND ASSOCIATED MATERIALS.
D2
D12
D6 2. DEMOLISH AND REMOVE SPRINKLER PIPING AND HEADS
D1 THROUGHOUT INCLUDING HANGERS AND FASTENERS.
D1 D3 D9 SPRINKLER RISERS TO REMAIN.
D4
3. EXISTING INCOMING DOMESTIC WATER METERS AND MAINS
VACANT INTO BUILDING SHALL REMAIN FOR FUTURE USE. ALL
D4 D9 D3 D2 D1 218 ST. CHARLES AVE. DOWNSTREAM PIPING SHALL BE REMOVED.
D6 BEARING WALL
BEARING WALL D2 FRAMING TO 4. EXISTING SEWER MAIN CONNECTIONS SHALL REMAIN FOR
FRAMING TO D1 FUTURE USE.
REMAIN D6 D6 REMAIN
D9 5. REMOVE FLOOR DRAINS AND SEAL PIPE BELOW SLAB.

6. REMOVE EXISTING GAS PIPING IF PRESENT.


D6 D6 D6 D1 D6

D3
D6 DEMOLITION NOTES-ELECTRICAL
D2 D9 D3 D1
D6 D1 1. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO
VACANT OPEN TO PROVIDE A COMPLETE DEMOLITION OF ELECTRICAL SYSTEMS
D1
BELOW CONNECTIONS TO THE ADJACENT BUILDINGS THAT MEETS THE
D1 REQUIREMENTS OF THE LISTED INFORMATION AND THE OWNER.
D4 D2 D1 D1 2. THE CONTRACTOR SHALL REMOVE ALL POWER
D9 CONNECTIONS TO 632 COMMON ST. AND 218 ST. CHARLES
FROM BUILDING 228 ST. CHARLES OR 634 COMMON ST. THIS
D2 INCLUDES ANY POSSIBLE BRANCH CIRCUITS THAT CROSS
D4 D1 BUILDING SEPARATION WALLS. POWER OUTAGE SHALL BE
D6 COORDINATED WITH THE BUILDING OWNERS AT A TIME THAT IS
D2 VACANT
CONVENIENT TO THEIR SCHEDULE.
D2 NO. REVISIONS
D1 D2
D3 D3 3. ALL ELECTRICAL CONDUITS, WIRES, CABLES, OR WIRE WAYS THAT
PENETRATE THE BUILDING SEPARATION WALL SHALL BE
D1 D3 REMOVED AND SEALED.
D3 D3 4. ALL SPECIAL SYSTEMS WIRING, CABLING AND CONDUITS FOR
D6 D6 D1 D6
D6 TELEPHONE, DATA, FIRE ALARM, SECURITY ETC. THAT
PENETRATE THE BUILDING SEPARATION WALL SHALL BE
REMOVED AND SEALED.

5. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO


REPAIR ANY DAMAGE DONE TO THE INTEGRITY OF THESE
SYSTEMS TO 634 COMMON ST. AND 228 SR. CHARLES. ALL CHECKED BY:
GRAVIER ST. (SIDE) CONDUIT PENETRATIONS SHALL BE SEALED WITH A MATERIAL
ADJOINING VACANT BUILDING
228 ST. CHARLES AVE. THIRD FLOOR - 4,500 SQ. FT. CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT
GASES WHEN TESTED IN ACCORDANCE WITH ASTM-E814. DRAWN BY:
(NOT A PART)
6. ALL EXISTING PANEL BOARD CIRCUIT DIRECTORIES TO ADJACENT
BUILDINGS SHALL BE UPDATED DENOTING "SPARE" FOR DATE:
BREAKERS THAT ARE NO LONGER USED. THE REMAINING 10/24/2023
1 THIRD FLOOR DEMOLITION PLAN BREAKERS SHALL BE LABELED AS LISTED WITH A PREFIX "EX".
THE DIRECTORIES SHALL BE DATED.

7. DEMOLISH AND REMOVE ALL ELECTRICAL BOXES, SWITCHES,


JOB NO.:

A-1 SCALE: 3/16" = 1'-0" CONDUITS, COMMUNICATION SYSTEMS, SECURITY SYSTEMS


CABLE AND WIRING THROUGHOUT THE PROJECT SITE.

8. DEMOLISH AND REMOVE ROOFTOP ELECTRICAL EQUIPMENT.

D-3
PROVIDE TEMPORARY COVERS AS NEEDED TO MAINTAIN
WATER TIGHT CONDITIONS.

SHEET 3 OF 5
ALL CHANGES OR ADDITIONAL WORK MUST BE APPROVED BY THE HDLC

1050 south norman c francis parkway, suite 241


D12
DEMOLITION NOTES-ARCHITECTURAL
D1 DEMOLISH AND REMOVE EXISTING INTERIOR PARTITION FULL
HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE, DATA,
COMMON ST. BASE, CHAIR RAIL, PILASTERS, VISION PANELS, PIPING,
CLEAN-OUTS, ETC.

new orleans, louisiana 70125


D2 REMOVE EXISTING DOOR, FRAME AND CASING. RETURN FIRST
FLOOR DOORS TO OWNER STOCK FOR POSSIBLE RE-USE.

terrell-fabacher
architects, l.l.c.
D3 DEMOLISH AND REMOVE EXISTING CASEWORK, PLATFORM
SHELVING, COUNTER ETC. IN ITS ENTIRETY. PROTECT
D16 D6
ADJOINING SURFACES TO REMAIN FROM DAMAGE.
D6 D16
D6 D4 DEMOLISH AND REMOVE EXISTING PANELLED KNEE WALL AND

504 566 1320


D6 CAP.
D11 D5 DEMOLISH AND REMOVE EXISTING TOILET ROOM PARTITIONS
AND ASSOCIATED FASTENERS.
D9 D3
D6 DEMOLISH AND REMOVE EXISTING WALL FURRING OR FINISH
FULL HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE,
D11 DATA, BASE, WAINSCOT, CHAIR RAIL, ETC.

D7 DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,


DUCTWORK, AND ASSOCIATED MATERIALS.

D8 REMOVE SUSPENDED CEILING SYSTEMS, ACOUSTICAL,


OPEN TO BELOW GYP. BD. AND PLASTER TO EXPOSE THE CEILING JOIST AND
STEEL BEAMS. THIS INCLUDES THE DEMOLITION OF LIGHT
FIXTURES, INSULATION, ABANDONED BUILDING COMPONENTS
(I.E. -DUCTS, REGISTERS, CONDUITS, PIPING, WIRING,
ROOF HATCH
FASTENERS ETC.). THIS INCLUDES ALL CEILINGS ON ALL
ABOVE TO FLOORS.
REMAIN
D9 DEMOLISH AND REMOVE ALL DAMAGED WOOD STRIP FLOORING
Approved separately AND SUB FLOOR. FLOORING/DECKING IN GOOD CONDITION ARE
under #23-30021-HDLC TO REMAIN.

project (will) (will not) be visited


These plans and specifications

requirements to the best of my


have been prepared by me or
D10 DEMOLISH AND REMOVE ALL EXISTING VINYL TILE AND MASTIC,
ADJOINING BUILDING

under my close supervision.


DEMOLITION OF SKY CARPET, PADS NAILING STRIPS, CERAMIC TILE AND THIN SET

knowledge and belief. The


200 ST. CHARLES AVE. BRIDGE BY OTHERS DOWN TO THE EXISTING CONCRETE OR WOOD DECKING.
CORRIDOR

periodically to review job


BEARING WALL

They comply with all city


(NOT A PART) UNDER SEPARATE
FRAMING TO D11 DEMOLISH AND REMOVE CLAY TILE AT ELEVATOR SHAFT.
CONTRACT
REMAIN REMOVE ELEVATOR CAB,ELEVATOR DOORS, CONTROLS,
GUIDERAILS, BRACKETS, MACHINE, CONDUITS, CABLES ETC.

D12 DEMOLISH AND REMOVE FIRE ESCAPE STAIRS AT THE ST.


CHARLES AVE. AND COMMON STREET FACADES. THROUGH
SKY
WALL FASTENERS TO BE CUT BACK FLUSH WITH BUILDING

progress.
STORAGE BRIDGE
D9 (NOT A PART)
FACE.
E.

D13 DEMOLISH AND REMOVE MECHANICAL SHED IN COURTYARD


AV

ABOVE THE FIRST FLOOR IN ITS ENTIRETY. PROVIDE


TEMPORARY COVERS AS NEEDED TO MAINTAIN WATER
TIGHT CONDITIONS.
RLES

DEMOLITION LEGEND 632 COMMON ST.


REMOVE EXISTING DOOR AND D14 DEMOLISH AND REMOVE PLASTER FURRING FROM ALL
DN D9 FRAME. PROVIDE TEMPORARY BEAMS AND COLUMNS TO EXPOSE THE CONDITION OF
THE STRUCTURAL MEMBERS.
HA

COVER AT OPENING IN PARTY


EXISTING SOLID MASONRY WALLS TO REMAIN. WALL. PERMANENT 3-HOUR FIRE
D15 REMOVE EXISTING WINDOW TO NOWHERE.
ST. C

RESISTANCE RATED INFILL TO BE


D3
PROVIDED BY OTHERS UNDER D16 REMOVE COVER FROM WINDOW OPENING.
SEPARATE CONTRACT

DEMOLITION PLANS FOR


218 ST. CHARLES AVE. &
EXISTING INTERIOR PARTITION TO REMAIN. D17 DEMOLISH AND REMOVE EXISTING PLUMBING FIXTURES AND
ASSOCIATED TRIM. REMOVE ALL WASTE AND WATER ROUGH
At interior side only.

LOUISIANA
INS AND CAP PLUMBING BELOW SLAB.
D6 No exterior work or
EXISTING PARTITION TO BE DEMOLISHED AND REMOVED
changes are approved D18 DEMOLISH AND REMOVE ROOFTOP MECHANICAL

632 COMMON ST.


IN ITS ENTIRETY.

CAMP ST. (SIDE)


AND PLUMBING EQUIPMENT. PROVIDE TEMPORARY
under this permit, TYP COVERS AS NEEDED TO MAINTAIN WATER TIGHT
CONDITIONS.

D3 D19 DEMOLISH AND REMOVE CHILLED WATER PIPING AND


D3 HEATING HOT WATER PIPING. REMOVE PIPING FROM
AIR HANDLER ON FIRST FLOOR, UP THROUGH SECOND
STORM FLOOR AND TRAVEL TO MECHANICAL SHED IN
D6 COURTYARD. CAP INSIDE ADJACENT BUILDING.
DRAIN D6 D15 D3
D9 D2

NEW ORLEANS,
D1 CORRIDOR UP BEARING WALL D20 DEMOLISH AND REMOVE DAMAGED GUTTER SYSTEM
D1 FRAMING TO
REMAIN
D1 D2
D1 D1 D1
D3 DEMOLITION NOTES-MECHANICAL/PLUMBING
D1 D3 D3 D6 OPEN TO BELOW 1. DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,

D1 D1 D1 D6 DUCTWORK, AND ASSOCIATED MATERIALS.


D1 VACANT 2. DEMOLISH AND REMOVE SPRINKLER PIPING AND HEADS
D6 D1 THROUGHOUT INCLUDING HANGERS AND FASTENERS.
D9
D1 D3 SPRINKLER RISERS TO REMAIN.
D12 D9
3. EXISTING INCOMING DOMESTIC WATER METERS AND MAINS
VACANT INTO BUILDING SHALL REMAIN FOR FUTURE USE. ALL
D3 D2 D1 218 ST. CHARLES AVE. BEARING WALL DOWNSTREAM PIPING SHALL BE REMOVED.
D6
BEARING WALL 4. EXISTING SEWER MAIN CONNECTIONS SHALL REMAIN FOR
FRAMING TO FRAMING TO FUTURE USE.
D6 D1 D6 REMAIN
REMAIN
D9 5. REMOVE FLOOR DRAINS AND SEAL PIPE BELOW SLAB.

6. REMOVE EXISTING GAS PIPING IF PRESENT.


D6 D6 D6 D1 D6
D2 D6 DEMOLITION NOTES-ELECTRICAL
D3 D3
D6 D1 D1
1. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO
OPEN TO PROVIDE A COMPLETE DEMOLITION OF ELECTRICAL SYSTEMS
D1 CONNECTIONS TO THE ADJACENT BUILDINGS THAT MEETS THE
BELOW
REQUIREMENTS OF THE LISTED INFORMATION AND THE OWNER.
D9 D1
D2 D1 D1 2. THE CONTRACTOR SHALL REMOVE ALL POWER
CONNECTIONS TO 632 COMMON ST. AND 218 ST. CHARLES
D9 FROM BUILDING 228 ST. CHARLES OR 634 COMMON ST. THIS
INCLUDES ANY POSSIBLE BRANCH CIRCUITS THAT CROSS
VACANT
D2 D1 BUILDING SEPARATION WALLS. POWER OUTAGE SHALL BE
D6 COORDINATED WITH THE BUILDING OWNERS AT A TIME THAT IS
VACANT CONVENIENT TO THEIR SCHEDULE.
D2 NO. REVISIONS
D1 D2 3. ALL ELECTRICAL CONDUITS, WIRES, CABLES, OR WIRE WAYS THAT
D3 D3 PENETRATE THE BUILDING SEPARATION WALL SHALL BE
REMOVED AND SEALED.
D1 D3
D3 D2 D3 4. ALL SPECIAL SYSTEMS WIRING, CABLING AND CONDUITS FOR
D6 D6 D6 D1 D6 TELEPHONE, DATA, FIRE ALARM, SECURITY ETC. THAT
D6 PENETRATE THE BUILDING SEPARATION WALL SHALL BE
REMOVED AND SEALED.

5. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO


REPAIR ANY DAMAGE DONE TO THE INTEGRITY OF THESE
SYSTEMS TO 634 COMMON ST. AND 228 SR. CHARLES. ALL CHECKED BY:
CONDUIT PENETRATIONS SHALL BE SEALED WITH A MATERIAL
GRAVIER ST. (SIDE)
ADJOINING VACANT BUILDING
228 ST. CHARLES AVE. FOURTH FLOOR - 4,500 SQ. FT. CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT
GASES WHEN TESTED IN ACCORDANCE WITH ASTM-E814. DRAWN BY:
(NOT A PART)
6. ALL EXISTING PANEL BOARD CIRCUIT DIRECTORIES TO ADJACENT
BUILDINGS SHALL BE UPDATED DENOTING "SPARE" FOR DATE:
BREAKERS THAT ARE NO LONGER USED. THE REMAINING 10/24/2023
BREAKERS SHALL BE LABELED AS LISTED WITH A PREFIX "EX".

1 FOURTH FLOOR DEMOLITION PLAN THE DIRECTORIES SHALL BE DATED.

7. DEMOLISH AND REMOVE ALL ELECTRICAL BOXES, SWITCHES,


JOB NO.:

A-1 SCALE: 3/16" = 1'-0" CONDUITS, COMMUNICATION SYSTEMS, SECURITY SYSTEMS


CABLE AND WIRING THROUGHOUT THE PROJECT SITE.

8. DEMOLISH AND REMOVE ROOFTOP ELECTRICAL EQUIPMENT.


PROVIDE TEMPORARY COVERS AS NEEDED TO MAINTAIN
WATER TIGHT CONDITIONS. D-4
SHEET 4 OF 5
ALL CHANGES OR ADDITIONAL WORK MUST BE APPROVED BY THE HDLC

1050 south norman c francis parkway, suite 241


DEMOLITION NOTES-ARCHITECTURAL
COMMON ST.
D1 DEMOLISH AND REMOVE EXISTING INTERIOR PARTITION FULL
HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE, DATA,
BASE, CHAIR RAIL, PILASTERS, VISION PANELS, PIPING,
CLEAN-OUTS, ETC.

new orleans, louisiana 70125


D2 REMOVE EXISTING DOOR, FRAME AND CASING. RETURN FIRST
FLOOR DOORS TO OWNER STOCK FOR POSSIBLE RE-USE.

terrell-fabacher
architects, l.l.c.
D3 DEMOLISH AND REMOVE EXISTING CASEWORK, PLATFORM
SHELVING, COUNTER ETC. IN ITS ENTIRETY. PROTECT
ADJOINING SURFACES TO REMAIN FROM DAMAGE.

D4 DEMOLISH AND REMOVE EXISTING PANELLED KNEE WALL AND

504 566 1320


CAP.

D5 DEMOLISH AND REMOVE EXISTING TOILET ROOM PARTITIONS


ELEVATOR AND ASSOCIATED FASTENERS.
PENTHOUSE
TO REMAIN D6 DEMOLISH AND REMOVE EXISTING WALL FURRING OR FINISH
FULL HEIGHT INCLUDING RELATED ELECTRICAL, TELEPHONE,
DATA, BASE, WAINSCOT, CHAIR RAIL, ETC.

HVAC D18 D7 DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,


UNIT DUCTWORK, AND ASSOCIATED MATERIALS.
OPEN TO BELOW
D8 REMOVE SUSPENDED CEILING SYSTEMS, ACOUSTICAL,
GYP. BD. AND PLASTER TO EXPOSE THE CEILING JOIST AND
STEEL BEAMS. THIS INCLUDES THE DEMOLITION OF LIGHT
FIXTURES, INSULATION, ABANDONED BUILDING COMPONENTS
(I.E. -DUCTS, REGISTERS, CONDUITS, PIPING, WIRING,
FASTENERS ETC.). THIS INCLUDES ALL CEILINGS ON ALL
FLOORS.

D9 DEMOLISH AND REMOVE ALL DAMAGED WOOD STRIP FLOORING


AND SUB FLOOR. FLOORING/DECKING IN GOOD CONDITION ARE
DEMOLITION OF SKY TO REMAIN.
BRIDGE BY OTHERS
ROOF HATCH

project (will) (will not) be visited


These plans and specifications

requirements to the best of my


ADJOINING BUILDING UNDER SEPARATE D10 DEMOLISH AND REMOVE ALL EXISTING VINYL TILE AND MASTIC,

have been prepared by me or


200 ST. CHARLES AVE. CONTRACT

under my close supervision.


CARPET, PADS NAILING STRIPS, CERAMIC TILE AND THIN SET

knowledge and belief. The


(NOT A PART) DOWN TO THE EXISTING CONCRETE OR WOOD DECKING.

periodically to review job


They comply with all city
D11 DEMOLISH AND REMOVE CLAY TILE AT ELEVATOR SHAFT.
SKY BRIDGE REMOVE ELEVATOR CAB,ELEVATOR DOORS, CONTROLS,
ROOF GUIDERAILS, BRACKETS, MACHINE, CONDUITS, CABLES ETC.

D12 DEMOLISH AND REMOVE FIRE ESCAPE STAIRS AT THE ST.


CHARLES AVE. AND COMMON STREET FACADES. THROUGH
VE.

WALL FASTENERS TO BE CUT BACK FLUSH WITH BUILDING

progress.
FACE.
ES A

632 COMMON ST. D13 DEMOLISH AND REMOVE MECHANICAL SHED IN COURTYARD
DEMOLITION LEGEND ABOVE THE FIRST FLOOR IN ITS ENTIRETY. PROVIDE
TEMPORARY COVERS AS NEEDED TO MAINTAIN WATER
L

TIGHT CONDITIONS.
A R

EXISTING SOLID MASONRY WALLS TO REMAIN. EXISTING BUILT-UP D14 DEMOLISH AND REMOVE PLASTER FURRING FROM ALL
H

ROOF SYSTEM TO BEAMS AND COLUMNS TO EXPOSE THE CONDITION OF


ST. C

THE STRUCTURAL MEMBERS.


REMAIN
D15 REMOVE EXISTING WINDOW TO NOWHERE.
EXISTING INTERIOR PARTITION TO REMAIN.
D16 REMOVE COVER FROM WINDOW OPENING.

DEMOLITION PLANS FOR


D17 DEMOLISH AND REMOVE EXISTING PLUMBING FIXTURES AND

218 ST. CHARLES AVE. &


EXISTING PARTITION TO BE DEMOLISHED AND REMOVED
ASSOCIATED TRIM. REMOVE ALL WASTE AND WATER ROUGH
IN ITS ENTIRETY.

CAMP ST. (SIDE)


INS AND CAP PLUMBING BELOW SLAB.

LOUISIANA
Installation of new HVAC
D18 DEMOLISH AND REMOVE ROOFTOP MECHANICAL
equipment requires

632 COMMON ST.


AND PLUMBING EQUIPMENT. PROVIDE TEMPORARY
separate mechanical COVERS AS NEEDED TO MAINTAIN WATER TIGHT
application, TYP CONDITIONS.

D19 DEMOLISH AND REMOVE CHILLED WATER PIPING AND


D18 HEATING HOT WATER PIPING. REMOVE PIPING FROM
AIR HANDLER ON FIRST FLOOR, UP THROUGH SECOND
PARAPET FLOOR AND TRAVEL TO MECHANICAL SHED IN
COURTYARD. CAP INSIDE ADJACENT BUILDING.

NEW ORLEANS,
D20 DEMOLISH AND REMOVE DAMAGED GUTTER SYSTEM

PARAPET OPEN TO BELOW DEMOLITION NOTES-MECHANICAL/PLUMBING


1. DEMOLISH AND REMOVE ALL MECHANICAL EQUIPMENT,
DUCTWORK, AND ASSOCIATED MATERIALS.

2. DEMOLISH AND REMOVE SPRINKLER PIPING AND HEADS


THROUGHOUT INCLUDING HANGERS AND FASTENERS.
SPRINKLER RISERS TO REMAIN.

3. EXISTING INCOMING DOMESTIC WATER METERS AND MAINS


EXISTING ROOF HVAC INTO BUILDING SHALL REMAIN FOR FUTURE USE. ALL
SYSTEM TO UNIT DOWNSTREAM PIPING SHALL BE REMOVED.
REMAIN
4. EXISTING SEWER MAIN CONNECTIONS SHALL REMAIN FOR
FUTURE USE.

5. REMOVE FLOOR DRAINS AND SEAL PIPE BELOW SLAB.

6. REMOVE EXISTING GAS PIPING IF PRESENT.


D18 D20

218 ST. CHARLES AVE. DEMOLITION NOTES-ELECTRICAL


OPEN TO
1. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO
BELOW
PROVIDE A COMPLETE DEMOLITION OF ELECTRICAL SYSTEMS
CONNECTIONS TO THE ADJACENT BUILDINGS THAT MEETS THE
REQUIREMENTS OF THE LISTED INFORMATION AND THE OWNER.

2. THE CONTRACTOR SHALL REMOVE ALL POWER


CONNECTIONS TO 632 COMMON ST. AND 218 ST. CHARLES
FROM BUILDING 228 ST. CHARLES OR 634 COMMON ST. THIS
INCLUDES ANY POSSIBLE BRANCH CIRCUITS THAT CROSS
BUILDING SEPARATION WALLS. POWER OUTAGE SHALL BE
COORDINATED WITH THE BUILDING OWNERS AT A TIME THAT IS
CONVENIENT TO THEIR SCHEDULE.

3. ALL ELECTRICAL CONDUITS, WIRES, CABLES, OR WIRE WAYS THAT NO. REVISIONS
PENETRATE THE BUILDING SEPARATION WALL SHALL BE
REMOVED AND SEALED.

4. ALL SPECIAL SYSTEMS WIRING, CABLING AND CONDUITS FOR


TELEPHONE, DATA, FIRE ALARM, SECURITY ETC. THAT
PENETRATE THE BUILDING SEPARATION WALL SHALL BE
REMOVED AND SEALED.

5. IT IS THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR TO


REPAIR ANY DAMAGE DONE TO THE INTEGRITY OF THESE
GRAVIER ST. (SIDE) SYSTEMS TO 634 COMMON ST. AND 228 SR. CHARLES. ALL
ADJOINING VACANT BUILDING
CONDUIT PENETRATIONS SHALL BE SEALED WITH A MATERIAL CHECKED BY:
228 ST. CHARLES AVE. CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT
(NOT A PART) GASES WHEN TESTED IN ACCORDANCE WITH ASTM-E814.
DRAWN BY:
6. ALL EXISTING PANEL BOARD CIRCUIT DIRECTORIES TO ADJACENT
BUILDINGS SHALL BE UPDATED DENOTING "SPARE" FOR
BREAKERS THAT ARE NO LONGER USED. THE REMAINING DATE:
10/24/2023
ROOF DEMOLITION PLAN
BREAKERS SHALL BE LABELED AS LISTED WITH A PREFIX "EX".

1 THE DIRECTORIES SHALL BE DATED.


JOB NO.:
7. DEMOLISH AND REMOVE ALL ELECTRICAL BOXES, SWITCHES,
A-1 SCALE: 3/16" = 1'-0" CONDUITS, COMMUNICATION SYSTEMS, SECURITY SYSTEMS
CABLE AND WIRING THROUGHOUT THE PROJECT SITE.

8. DEMOLISH AND REMOVE ROOFTOP ELECTRICAL EQUIPMENT.


PROVIDE TEMPORARY COVERS AS NEEDED TO MAINTAIN
WATER TIGHT CONDITIONS.
D-5
SHEET 5 OF 5