ZNL Bro en 3607-1071-12 v0800
ZNL Bro en 3607-1071-12 v0800
year
Product Brochure
Version 08.00
AT A GLANCE
RF measuring equipment has to meet high quality standards. It should be easy to use and highly versatile
for fast measurements and reliable performance. The R&S®ZNL meets all of these challenges and all models
can now combine a vector network analyzer, a spectrum analyzer and a power meter in a single, compact
box.
The R&S®ZNL is ideal for RF component testing of indus- The R&S®ZNL hosts a variety of different functions. Instead
trial electronics, EMC and wireless communications with of investing in multiple instruments, research labs, service
frequency ranges from 5 kHz up to 20 GHz. centers, universities and production facilities can benefit
from a single, compact device with very fast measurement
Responding to constantly changing measurement needs speeds and better RF performance than dedicated instru-
in diverse environments (test benches or production lines) ments in comparable classes. The R&S®ZNL can simul-
can be challenging. The R&S®ZNL reduces investment taneously display vector network a nalyzer and spectrum
costs and offers a unique option concept. The base unit analyzer measurements on its 10.1" multitouch screen
can be extended to a fully integrated spectrum a
nalyzer with the R&S®ZNLx‑B1 option. Clear menu structures and
and an RF power meter 1). numerous wizards make for convenient measurement
configurations.
2
KEY FEATURES
► Frequency ranges ► Wide dynamic range of typ. 130 dB
BENEFITS
The 3-in-1 analyzer:
compact v ector network analyzer
►page 4
Measurement on a high-rejection bandpass filter using the bandpass filter function. Fixture compensation menu, showing the available compensation methods.
4
R&S®ZNL and used for deembedding/embedding. Fixture The distance-to-fault measurement option (R&S®ZNL-K3)
compensation adjusts measurement results to eliminate can detect cable discontinuities when installing base sta-
the unwanted effects of test fixtures or adapters located tion antennas. A range of common cable types with pre-
between the calibrated reference plane and the DUT. defined velocity factors and frequency-dependent attenu-
ation are available. Users can also create their own cable
Remote control via LAN and optional GPIB interface profiles. The R&S®ZNL-K2 and R&S®ZNL-K3 options use
The R&S®ZNL can be remotely controlled with a stan- internal DC extrapolation. The low start frequency of 5 kHz
dard LAN interface. A remote controller can be connected improves accuracy.
to the R&S®ZNL with an optional GPIB interface. Data is
transmitted bidirectionally on the 8-bit parallel bus. The Compact 3-in-1 instrument up to 6 GHz
measured data from a sweep is transferred to the control- The R&S®ZNL is the most compact instrument in its class
ler while the next sweep is in progress, making data trans- with a depth of less than 24 cm and weighing just 6 to
fer times for the R&S®ZNL all but negligible. 8 kg. The small footprint frees up more space on your
workbench than any other comparable benchtop analyzer.
Time domain analysis and distance-to-fault (DTF)
measurements The R&S®ZNLx-B1 spectrum analyzer option saves even
The R&S®ZNL offers a powerful time domain analysis more space by combining the capacity of two analyzers in
option (R&S®ZNL-K2) to measure components such as the same compact size. R&S®NRP power sensor support
filters and high-speed digital data cables in the frequency adds a power m eter function that transforms the R&S®ZNL
and time domain. into a 3-in-1 allrounder by combining a network analyzer,
spectrum analyzer and power meter in a single box.
With 100 001 points per trace, the R&S®ZNL can measure
long electrical DUTs such as cables without any limita-
tions. The R&S®ZNL gating function makes cable faults
easy to locate and analyze in detail.
~ 29 % more space
~ 67 % more space
6
Analog demodulation Digital demodulation
The R&S®FPL1-K7 option adds analog demodulation capa- The R&S®ZNL with the R&S®ZNLx-B1 spectrum analysis
bilities to the R&S®ZNL to determine amplitude, frequency option has up to 40 MHz analysis bandwidth to analyze
and phase modulated signals while measuring other com- and demodulate digitally modulated single-carrier signals.
ponents such as residual FM and synchronous modula- The R&S®ZNL receives and digitalizes a signal, which the
tion. Typical R&S®FPL1-K7 applications include: R&S®VSE vector signal explorer software on the R&S®ZNL
► Transient and settling time measurements of oscillators or an external PC 1) then analyzes.
such as VCOs and PLLs
► Troubleshooting AM/FM transmitters
► Simple chirp analysis of pulsed and continuous wave
signals 1)
For further information, see R&S®VSE product brochure (PD 3607.1371.12) and
www.rohde-schwarz.com/product/vse.
8
Independent continuous wave (CW) source The R&S®ZNL-K14 option allows for a more detailed anal-
All R&S®ZNL models with the R&S®ZNLx‑B1 spectrum ysis of the DUT frequency response and can measure
analyzer option in combination with R&S®ZNL-K14 inde- parameters such as harmonics and search for spurious
pendent CW source option can measure the output fre- frequency components. The option also enables measure-
quency spectrum of a DUT connected to port 2, with the ments on frequency-converting DUTs if an external signal
DUT input driven by a CW signal from port 1. source is present.
CW at 1 GHz
DUT
Frequency sweep of a
common mode trans-
former output signal
using a CW input signal
of 0 dBm at 1 GHz.
Toolbar
► Fast access to standard functions such as
print, save/open file, undo, redo, help
System keys
► For setups, presets, etc.
Status bar
10
Softkey bar
► Quick access to key functions
► Hardware settings at a glance
Numerical keypad
► With unit keys for
frequency and level
Function keys
Control knob
12
FULLY PORTABLE – IDEAL FOR FIELD USE
The unique R&S®ZNL hardware concept combines multiple Calibration accessories are also portable
functions in a low-weight compact form factor. Depending The economy 2-port calibration kits in the R&S®ZN-Z1xx
on the options, the R&S®ZNL weighs between 6 kg and series are robust and lightweight for easy carrying in a
8 kg. transport bag or neck strap. If you want to simplify calibra-
tion, while reducing operator errors and improving calibra-
Battery and DC power supplies for field use tion repeatability, the R&S®ZN-ZE1xx economy calibration
The R&S®ZNL has a carrying handle and an optional units are ideal and offer the same portability. Their flexible
battery pack (R&S®FPL1-B31), making it fully portable connector configuration concept addresses all use cases
and ideal for field use and quick transfers between lab for N-types, a 3.5 mm or a 2.92 mm connectors for fre-
workstations. quencies ranging from 5 kHz up to 26.5 GHz.
Rear view of the R&S®ZNL with battery compartment. The batteries are easy to
The R&S®ZNL can be stowed and carried in a robust transport bag. access.
14
ORDERING INFORMATION
Designation Type Order No.
Base unit
Vector network analyzer, 5 kHz to 3 GHz, two ports, N (f) R&S®ZNL3 1323.0012.03
Vector network analyzer, 5 kHz to 4.5 GHz, two ports, N (f) R&S®ZNL4 1323.0012.04
Vector network analyzer, 5 kHz to 6 GHz, two ports, N (f) R&S®ZNL6 1323.0012.06
Vector network analyzer, 5 kHz to 14 GHz, two ports, N (f) R&S®ZNL14 1323.0012.14
Vector network analyzer, 5 kHz to 20 GHz, two ports, 3.5 mm (m) R&S®ZNL20 1323.0012.20
Hardware options
Spectrum analyzer function for R&S®ZNL3 R&S®ZNL3-B1 1323.1802.02
Spectrum analyzer function for R&S®ZNL4 R&S®ZNL4-B1 1303.8099.02
Spectrum analyzer function for R&S®ZNL6 R&S®ZNL6-B1 1323.2067.02
Spectrum analyzer function for R&S®ZNL14 R&S®ZNL14-B1 1303.8082.02
Spectrum analyzer function for R&S®ZNL20 R&S®ZNL20-B1 1303.8101.02
Extended power range for R&S®ZNL3 R&S®ZNL3-B22 1323.1860.02
Extended power range for R&S®ZNL4 R&S®ZNL4-B22 1303.8118.02
Extended power range for R&S®ZNL6 R&S®ZNL6-B22 1323.2021.02
Extended power range for R&S®ZNL14 R&S®ZNL14-B22 1303.8153.02
Extended power range for R&S®ZNL20 R&S®ZNL20-B22 1303.9089.02
Receiver step attenuator for R&S®ZNL3, port 1 R&S®ZNL3-B31 1323.1848.02
Receiver step attenuator for R&S®ZNL3, port 2 R&S®ZNL3-B32 1323.1854.02
Receiver step attenuator for R&S®ZNL4, port 1 R&S®ZNL4-B31 1303.8124.02
Receiver step attenuator for R&S®ZNL4, port 2 R&S®ZNL4-B32 1303.8130.02
Receiver step attenuator for R&S®ZNL6, port 1 R&S®ZNL6-B31 1323.2038.02
Receiver step attenuator for R&S®ZNL6, port 2 R&S®ZNL6-B32 1323.2044.02
Receiver step attenuator for R&S®ZNL14, port 1 R&S®ZNL14-B31 1303.8160.02
Receiver step attenuator for R&S®ZNL14, port 2 R&S®ZNL14-B32 1303.8176.02
Receiver step attenuator for R&S®ZNL20, port 1 R&S®ZNL20-B31 1303.9095.02
Receiver step attenuator for R&S®ZNL20, port 2 R&S®ZNL20-B32 1303.9108.02
Additional removable PC board with SSD R&S®ZNL-B19 1323.2938.02
OCXO accurate reference frequency R&S®FPL1-B4 1323.1902.02
Additional interfaces R&S®FPL1-B5 1323.1883.02
GPIB interface R&S®FPL1-B10 1323.1890.02
YIG preselector bypass 1), 6) R&S®FPL1-B11 1323.1619.02
DC power supply (12 V/24 V) R&S®FPL1-B30 1323.1877.02
Lithium-ion battery pack R&S®FPL1-B31 1323.1725.02
40 MHz analysis bandwidth 1)
R&S®FPL1-B40 1323.1931.02
Software options
Time domain analysis R&S®ZNL-K2 1323.1819.02
Distance-to-fault measurements R&S®ZNL-K3 1323.1825.02
Independent CW source R&S®ZNL-K14 1303.8182.02
AM/FM/φM analog modulation analysis 1)
R&S®FPL1-K7 1323.1731.02
Measurements with R&S®NRP power sensors 1) R&S®FPL1-K9 1323.1754.02
Noise figure measurements 1), 2) R&S®FPL1-K30 1323.1760.02
Please contact your local
R&S®VSE signal explorer software plus selected options 3)
Rohde & Schwarz sales office.
Recommended extras
Calibration kits
Calibration kit, N (m), 50 Ω, 0 Hz to 18 GHz R&S®ZN-Z170 1328.8163.02
Calibration kit, N (f), 50 Ω, 0 Hz to 18 GHz R&S®ZN-Z170 1328.8163.03
Calibration kit, 3.5 mm (m), 50 Ω, 0 Hz to 26.5 GHz R&S®ZN-Z135 1328.8157.02
Calibration kit, 3.5 mm (f), 50 Ω, 0 Hz to 26.5 GHz R&S®ZN-Z135 1328.8157.03
1)
Requires R&S®ZNLx-B1 hardware option.
2)
Requires R&S®FPL1‑B5 hardware option for noise source control.
3)
For further information on the R&S®VSE vector signal explorer software, see PD 3607.1371.12 and www.rohde-schwarz.com/product/vse.
4)
Requires R&S®RT-ZA9.
5)
Requires R&S®FPL1-K30 software option.
6)
Only available for R&S®ZNL14 and R&S®ZNL20.
Warranty
Base unit 3 years
All other items 1) 1 year
Options
Extended warranty, one year R&S®WE1
Extended warranty, two years R&S®WE2
Extended warranty with calibration coverage, one year R&S®CW1 Please contact your local
Extended warranty with calibration coverage, two years R&S®CW2 Rohde & Schwarz sales office.
Extended warranty with accredited calibration coverage, one year R&S®AW1
Extended warranty with accredited calibration coverage, two years R&S®AW2
1)
For options installed, the remaining base unit warranty applies if longer than 1 year. Exception: all batteries have a 1 year warranty.
Finland
Norway
Sweden Estonia
Latvia
Denmark Lithuania
United Russian
Kingdom Poland Federation
Netherlands
Serbia Bulgaria
Italy
Spain Azerbaijan
Portugal
Greece Turkey
Malta Cyprus
Canada
Cologne Germany
Teisnach
Portland Ottawa Memmingen Kazakhstan
Toronto Mongolia
Azerbaijan
Columbia/Maryland Beijing
USA Japan
Seoul
Los Angeles Islamabad Xi'an South Daejeon Saitama
Dallas Algeria Korea Tokyo
Chengdu Gumi City Osaka
Pakistan China
Monterrey Egypt UAE Shanghai
Saudi Karachi New Delhi Guangzhou Taipei
Mexico Arabia India Taiwan
Shenzhen
Mexico City Oman Kaohsiung
Mumbai Hong
Hyderabad Hanoi
Kong
Vietnam
Ho Chi Philippines
Thailand
Sales locations Bangalore Minh City
Penang
Malaysia
Lead service centers Selangor
Colombia
Singapore
Service centers
Indonesia
Brazil
Rio de Janeiro
New Zealand
www.rohde-schwarz.com
3607107112