R&S®ZNL

VECTOR NETWORK ANALYZER


The 3-in-1 allrounder

year
Product Brochure
Version 08.00
AT A GLANCE
RF measuring equipment has to meet high quality standards. It should be easy to use and highly versatile
for fast measurements and reliable performance. The R&S®ZNL meets all of these challenges and all models
can now combine a vector network analyzer, a spectrum analyzer and a power meter in a single, compact
box.

The R&S®ZNL is ideal for RF component testing of indus- The R&S®ZNL hosts a variety of different functions. Instead
trial electronics, EMC and wireless communications with of investing in multiple instruments, research labs, service
frequency ranges from 5 kHz up to 20 GHz. centers, universities and production facilities can benefit
from a single, compact device with very fast measurement
Responding to constantly changing measurement needs speeds and better RF performance than dedicated instru-
in ­diverse environments (test benches or production lines) ments in comparable classes. The R&S®ZNL can simul-
can be challenging. The R&S®ZNL reduces investment taneously display vector network a­ nalyzer and spectrum
costs and offers a unique option concept. The base unit analyzer measurements on its 10.1" multi­touch screen
can be extended to a fully integrated spectrum a
­ nalyzer with the R&S®ZNLx‑B1 option. Clear menu structures and
and an RF power meter 1). numerous ­wizards make for convenient measurement
configurations.

The R&S®ZNL offers a wide range of functions in a very


compact size. Weighing just 6 kg to 7.3 kg, with a carrying
1)
R&S®FPL1-K9 option; requires R&S®ZNLx-B1 option and an R&S®NRP external
handle and an optional battery pack, the R&S®ZNL is fully
power sensor. portable and can be operated wherever needed.

2
KEY FEATURES
► Frequency ranges ► Wide dynamic range of typ. 130 dB

– R&S®ZNL3: 5 kHz to 3 GHz ► Output power range from –40 dBm to

– R&S®ZNL4: 5 kHz to 4.5 GHz typ. + 3 dBm


► Measurement bandwidths from 1 Hz to 500 kHz
– R&S®ZNL6: 5 kHz to 6 GHz
► Fast measurements of 16.7 ms for 401 points
– R&S®ZNL14: 5 kHz to 14 GHz
(100 kHz IFBW, 200 MHz span,
– R&S®ZNL20: 5 kHz to 20 GHz two-port TOSM (SOLT))
► Two-port vector network analyzer for bidirectional ► Compact size, low weight (6 kg to 8 kg)
measurements
► Optional battery pack
► Universal instrument
► Windows 10 operating system
– Vector network analyzer
– Fully integrated spectrum analyzer
– Support for external power sensors

BENEFITS
The 3-in-1 analyzer:
­compact v­ ector network analyzer
►page 4

The 3-in-1 analyzer: fully ­integrated


spectrum analyzer
►page 6

The 3-in-1 analyzer: RF power meter


►page 7

Clearly structured user interface


►page 8

User interface with multitouch screen


►page 10

Fully portable – ideal for field use


►page 11

Rohde & Schwarz R&S®ZNL Vector Network Analyzer 3


THE 3-IN-1 ANALYZER:
­COMPACT ­VECTOR NETWORK ANALYZER
With the appropriate options, the R&S®ZNL can combine a high-speed data processing and fast LAN or IEC/IEEE/
vector network analyzer, a spectrum analyzer and a power GPIB data transfer. The segmented sweep function can
meter in a single, compact box. The all-in-one instrument help maximize throughput. The frequency axis is divided
is ideal for development, production and service environ- into segments and sweep parameters such as output
ments with their constantly changing test r­ equirements. power, IF bandwidth and t­ he number of points are defined
separately for each segment to best match the DUT char-
Solid RF performance acteristics and increase measurement speed without sacri-
The R&S®ZNL is a vector network analyzer that can char- ficing accuracy.
acterize electronic networks in the frequency domain
by measuring S-parameters, magnitude and phase. The Production and lab features
R&S®ZNL-K2 option can analyze components in the time Versatile calibration features, calibration unit support
domain. The R&S®ZNL calibration wizard guides users through the
calibration process and supports both manual calibration
High dynamic range kits and automatic calibration units. Automatic calibration
The R&S®ZNL features a wide dynamic range of up to units minimize the time needed to correct system errors.
130 dB (typ. at 10 Hz IFBW) and typical output power of The calibration unit can be used upon connection to the
3 dBm. These values help with measurements on high-­ R&S®ZNL. A setup can be calibrated in a few simple steps,
rejection filters that require a wide dynamic range. a big benefit in production environments, where ­saving
time and maximizing throughput are critical. A single
Low trace noise for high accuracy click on the “Start Auto Cal” button starts the calibration
The R&S®ZNL has low trace noise of less than 0.0025 dB process.
(typically at 10 kHz IFBW) for stable, reproducible and
precise measurements even at higher IF bandwidths. The De/embedding and fixture compensation
R&S®ZNL uses higher IF bandwidths for faster measure- Components are often specified together with the net-
ments while maintaining the stability normal for narrower works that match them to the impedance of the surround-
IF bandwidths. ing circuit. When characterizing such components in a
production environment, the R&S®ZNL can embed the
Fast measurements for high throughput DUT into a virtual matching network for realistic condi-
The R&S®ZNL satisfies production speed requirements tions that simulate a DUT being installed in an operational
with measurement times of 16.7 ms for 401 points (full environment. The R&S®ZNL offers predefined matching
two-port calibration, 200 MHz span, 100 kHz IFBW), network topologies. Touchstone files can be fed into the

Measurement on a high-rejection bandpass filter using the bandpass filter function. Fixture compensation menu, showing the available compensation methods.

4
R&S®ZNL and used for deembedding/embedding. Fixture The distance-to-fault measurement option (R&S®ZNL-K3)
compensation adjusts measurement results to eliminate can detect cable discontinuities when installing base sta-
the unwanted effects of test fixtures or adapters located tion antennas. A range of common cable types with pre-
between the calibrated reference plane and the DUT. defined velocity factors and frequency-­dependent attenu-
ation are available. Users can also create their own cable
Remote control via LAN and optional GPIB interface profiles. The R&S®ZNL-K2 and R&S®ZNL-K3 options use
The R&S®ZNL can be remotely controlled with a stan- internal DC ­extrapolation. The low start frequency of 5 kHz
dard LAN interface. A remote controller can be connected improves accuracy.
to the R&S®ZNL with an optional GPIB interface. Data is
transmitted bidirectionally on the 8-bit parallel bus. The Compact 3-in-1 instrument up to 6 GHz
measured data from a sweep is transferred to the control- The R&S®ZNL is the most compact instrument in its class
ler while the next sweep is in progress, making data trans- with a depth of less than 24 cm and weighing just 6 to
fer times for the R&S®ZNL all but negligible. 8 kg. The small footprint frees up more space on your
workbench than any other comparable benchtop analyzer.
Time domain analysis and distance-to-fault (DTF)
measurements The R&S®ZNLx-B1 spectrum analyzer option saves even
The R&S®ZNL offers a powerful time domain analysis more space by combining the capacity of two analyzers in
option (R&S®ZNL-K2) to measure components such as the same compact size. R&S®NRP power sensor support
­filters and high-speed digital data cables in the frequency adds a power m ­ eter function that transforms the R&S®ZNL
and time domain. into a 3-in-1 ­allrounder by combining a network analyzer,
spectrum analyzer and power meter in a single box.
With 100 001 points per trace, the R&S®ZNL can measure
long electrical DUTs such as cables without any limita-
tions. The R&S®ZNL gating function makes cable faults
easy to locate and analyze in detail.

Footprints for different VNAs

Instrument 1 Instrument 2 ¸ZNL


484 mm × 590 mm 432 mm × 310 mm 408 mm × 235 mm
80 cm

~ 29 % more space

~ 67 % more space

Rohde & Schwarz R&S®ZNL Vector Network Analyzer  5


THE 3-IN-1 ANALYZER: FULLY ­INTEGRATED
SPECTRUM ANALYZER
Different operating modes transform the R&S®ZNL vector The spectrum analyzer function includes an I/Q analyzer,
­network analyzer into a versatile multipurpose instrument. standard for digital signal analysis. This application has
The R&S®ZNLx-B1 hardware option expands the base unit measurement and display functions for I/Q data. The
to include a fully integrated spectrum analyzer on a dedi- captured I/Q data can be transferred to third-party soft-
cated hardware board. Switching between modes no lon- ware tools (MATLAB® or Python) for further analysis. The
ger requires a reboot. 40 MHz analysis bandwidth option (R&S®FPL1-B40) can
analyze and demodulate single-carrier signals with up to
Integrated hardware for solid RF performance 40 MHz of bandwidth.
The R&S®ZNLx-B1 ­options use dedicated hardware boards
for performance comparable to dedicated economy and Preselector bypass
midrange spectrum ­analyzers. The R&S®ZNL with spec- The spectrum analyzer hardware for R&S®ZNL14 and
trum analyzer hardware typically has phase noise of R&S®ZNL20 vector analyzers uses a YIG filter to reject
–108 dBc (1 Hz) at 10 kHz offset, a typical third-order inter- images for frequencies higher than 6 GHz. The YIG prese-
cept point of up to +22 dBm and a typical displayed aver- lector might need to be disabled for broadband analysis.
age noise level (DANL) of up to –150 dBm. The R&S®FPL1-B11 option can bypass the YIG filter and
should be included with the R&S®FPL1-B40 option. This is
Spectrum analyzer function especially useful for I/Q analysis at frequencies higher than
In spectrum analyzer mode, the R&S®ZNL can function as 6 GHz.
a conventional spectrum analyzer for up to 26.5 GHz. The
analyzer measures the RF input signal frequency spectrum
over the selected range with the selected resolution and
sweep times. The video signal waveform for a fixed fre-
quency can also be displayed. The application is ­available
for all R&S®ZNL m­ odels with the R&S®ZNLx-B1 spectrum
analyzer option.

Spectrum analyzer mode: the R&S®ZNL p­ rovides


the full functionality of a standard spectrum
analyzer.

6
Analog demodulation Digital demodulation
The R&S®FPL1-K7 option adds analog demodulation capa- The R&S®ZNL with the R&S®ZNLx-B1 spectrum analysis
bilities to the R&S®ZNL to determine amplitude, frequency option has up to 40 MHz analysis bandwidth to analyze
and phase modulated signals while measuring other com- and demodulate digitally modulated single-carrier signals.
ponents such as residual FM and synchronous modula- The R&S®ZNL ­receives and digitalizes a signal, which the
tion. Typical R&S®FPL1-K7 applications include: R&S®VSE vector signal explorer software on the R&S®ZNL
► Transient and settling time measurements of oscillators or an external PC 1) then analyzes.
such as VCOs and PLLs
► Troubleshooting AM/FM transmitters
► Simple chirp analysis of pulsed and continuous wave
signals 1)
For ­further ­information, see R&S®VSE product brochure (PD 3607.1371.12) and
www.rohde-schwarz.com/product/vse.

Overview of analog demodulation menu: all setting


functions are accessible here.

Rohde & Schwarz R&S®ZNL Vector Network Analyzer  7


THE 3-IN-1 ANALYZER:
RF POWER METER UP
Precise power measurements Power sensors can be connected via USB or the
The R&S®FPL1-K9 option supports R&S®NRP p ­ ower sen- ruggedized power sensor connector included with the
sors 1) and enables precise power measurements. It R&S®FPL1-B5 additional interface option.
requires the R&S®ZNLx-B1 spectrum analyzer option.
Up to four power sensors can be connected in ­parallel.
The power sensors can also trigger measurements at
­defined power levels.
1)
For a complete list of R&S®NRP power sensors supported by R&S®FPL1-K9,
please refer to the product b
­ rochure (PD 3606.7147.32).

Examples of R&S®NRP power sensors:


R&S®NRP8SN and R&S®NRP8S three-path diode
power sensors.

The R&S®ZNL with the


R&S®FPL1‑K9 option s­ upports
external R&S®NRP power ­sensors
for precise power measurements.

8
Independent continuous wave (CW) source The R&S®ZNL-K14 option allows for a more detailed anal-
All R&S®ZNL models with the R&S®ZNLx‑B1 spectrum ysis of the DUT frequency response and can measure
analyzer option in combination with R&S®ZNL-K14 inde- parameters such as harmonics and search for spurious
pendent CW source option can measure the output fre- frequency components. The option also enables measure-
quency spectrum of a DUT ­connected to port 2, with the ments on frequency-converting DUTs if an external signal
DUT input ­driven by a CW signal from port 1. source is present.

R&S®ZNL-K14 measurement concept

CW at 1 GHz

DUT

Frequency sweep of a
common mode trans-
former output signal
using a CW input ­signal
of 0 dBm at 1 GHz.

Rohde & Schwarz R&S®ZNL Vector Network Analyzer  9


CLEARLY STRUCTURED USER INTERFACE

10.1" high-resolution multitouch screen


► 1280 × 800 pixel

Toolbar
► Fast access to standard functions such as
print, save/open file, undo, redo, help

System keys
► For setups, presets, etc.

Two USB 2.0 ports


► For storage media
► For accessories

Status bar

10
Softkey bar
► Quick access to key functions
► Hardware settings at a glance
Numerical keypad
► With unit keys for
frequency and level

Function keys

Control knob

Port 1 Port 2/RF input

Rohde & Schwarz R&S®ZNL Vector Network Analyzer  11


USER INTERFACE WITH MULTITOUCH
SCREEN
Clear menu structures for efficient operation Large 10.1" multitouch screen for convenient operation
The R&S®ZNL has a clearly structured user interface. The large 10.1" multitouch screen can be used to arrange
Measurements can be configured in just a few steps. measurement tasks and move and combine traces, chan-
nels and diagrams with the drag & drop function.
Users can drag and drop traces, channels and diagrams
that can be arranged and combined as needed. Different Integrated PC
instrument setups can be saved and reloaded and switch- The fully integrated, powerful PC platform uses the
ing between setups is easy. Windows 10 operating system and transforms the
R&S®ZNL into a standalone solution. No external PCs or
The R&S®ZNL has several marker functions to efficiently controllers are needed. The solid state hard disk ensures
analyze measured traces: fast boot times and high reliability to satisfy even the most
► Over 100 markers are available per trace (up to 16 in demanding requirements.
spectrum analyzer mode). Results are represented
in different formats such as magnitude, phase, Simultaneous display of multiple measurement modes with
impedance, admittance and VSWR. MultiView function
► The marker unit can be selected independently of the To support full DUT characterization, the MultiView func-
displayed trace format. tion simultaneously displays all active vector network
► Markers and traces can be named to describe the analyzers, spectrum analyzers and power meter measure-
specific application. ments. Measurements are updated in real time and can be
► Available marker functions include maximum, accessed directly by tapping the desired window.
minimum, RMS and peak-to-peak detection, bandwidth
measurement, etc. ­ lternating vector network analyzer measurements and
A
spectrum ­analyzer measurements can be performed with
Users can also define limit lines to verify DUT compliance the test sequencer in MultiView mode.
with specified values and required standards. Limit lines
can be defined as linear or logarithmic or a mathematical
formula can be applied.

In MultiView mode, all active measure­


ments are displayed simultaneously. A
vector network ­analyzer measure­ment
(two different r­ epresentations) is dis-
played alongside a s­ pectrum a­ nalyzer
measurement.

12
FULLY PORTABLE – IDEAL FOR FIELD USE

The unique R&S®ZNL hardware concept combines multiple Calibration accessories are also portable
functions in a low-weight compact form factor. Depending The economy 2-port calibration kits in the R&S®ZN-Z1xx
on the options, the R&S®ZNL weighs between 6 kg and series are robust and lightweight for easy carrying in a
8 kg. transport bag or neck strap. If you want to simplify calibra-
tion, while reducing operator errors and improving calibra-
Battery and DC power supplies for field use tion repeatability, the R&S®ZN-ZE1xx economy calibration
The R&S®ZNL has a carrying handle and an optional units are ideal and offer the same portability. Their flexible
battery pack (R&S®FPL1-B31), making it fully portable connector configuration concept addresses all use cases
and ideal for field use and quick transfers between lab for N-types, a 3.5 mm or a 2.92 mm connectors for fre-
workstations. quencies ranging from 5 kHz up to 26.5 GHz.

With the 12 V/24 V DC power supply (R&S®FPL1-B30), the


R&S®ZNL can be operated in a vehicle.
The new configurable R&S®ZN-ZE104, R&S®ZN-ZE109, R&S®ZN-ZE118 and
Transport and field use accessories R&S®ZN-ZE126 calibration units provide great performance in a compact, lightweight
When transporting or using the R&S®ZNL in the field, and economic solution.
the optional R&S®FPL1-Z2 transport bag protects it from
damage and dirt. Side vents and a transparent top cover
allow portable operation while it remains safely stored
in the bag. A carrying vest holster (R&S®FPL1-Z3) is also
available.

For outdoor use in challenging light conditions, an anti-


glare film (R&S®FPL1-Z5) is available for the display to
improve contrast and protect the screen from scratches.

Rear view of the R&S®ZNL with battery compartment. The batteries are easy to
The R&S®ZNL can be stowed and carried in a robust transport bag. access.

Rohde & Schwarz R&S®ZNL Vector Network Analyzer  13


SPECIFICATIONS IN BRIEF
Specifications in brief
Network analysis
Frequency range R&S®ZNL3 5 kHz to 3 GHz
R&S®ZNL4 5 kHz to 4.5 GHz
R&S®ZNL6 5 kHz to 6 GHz
R&S®ZNL14 5 kHz to 14 GHz
R&S®ZNL20 5 kHz to 20 GHz
Dynamic range up to > 120 dB (spec.); up to > 130 dB (typ.)
Output power 0 dBm (spec.); typ. + 3 dBm
Trace noise < 0.0045 dB (spec.); < 0.0025 dB (typ.)
Measurement speed
401 points, two-port TOSM,
Sweep time 16.7 ms
200 MHz span, 100 kHz IFBW
Data transfer over IEC/IEEE/GPIB, 201 points 3 ms (typ.)
HiSLIP over 1 Gbit/s LAN 2.5 ms (typ.)
S-parameters (Sxy), wave quantities, wave ratios, impedance
Measurement parameters
parameters (Zxy), a­ dmittance parameters (Y), stability factors
dB, magnitude, phase, Smith chart, polar diagram, SWR,
Display formats ­unwrapped phase, linear magnitude, inverse Smith chart, real,
imaginary, delay
reflection normalization (open or short), reflection (OSM (OSL)),
enhanced reflection normalization (OM or SM), transmission
Calibration methods normalization (response calibration), transmission normaliza-
tion in both directions (response calibration), one-path two-
port, TOSM (SOLT), TRL
Number of points vector network analyzer mode 1 to 100 001
spectrum analyzer mode 101 to 100 001
selectable in steps of 1/1.5/2/3/5/7 · 1 Hz/10 Hz/... /100 kHz;
IF bandwidth (IFBW)
max. upper limit: 500 kHz
Spectrum analysis
Frequency range R&S®ZNL3 5 kHz to 3 GHz (1 Hz resolution)
R&S®ZNL4 5 kHz to 4.5 GHz (1 Hz resolution)
R&S®ZNL6 5 kHz to 6 GHz (1 Hz resolution)
R&S®ZNL14 5 kHz to 14 GHz (1 Hz resolution)
R&S®ZNL20 5 kHz to 26.5 GHz (1 Hz resolution)
Displayed average noise level (DANL) RF attenuation: 0 dB < –112 dBm (spec.); < –120 dBm (typ.)
Phase noise 1 GHz, 10 kHz offset < –105 dBc (1 Hz); < –108 dBc (1 Hz) (typ.)
Maximum signal analysis bandwidth with R&S®FPL1-B40 option 40 MHz
Intermodulation
Third-order intercept point (TOI) 300 MHz ≤ fin ≤ 3 GHz > 16 dBm (spec.); > 22 dBm (typ.)
Second-harmonic intercept (SHI) 900 MHz ≤ fin ≤ 13.25 GHz 70 dBm (nom.)
General features
single, segmented, upper limit, lower limit, linear, logarithmic,
Limit lines vector network analyzer mode
based on formula
Number of channels within one vector network analyzer setup no limitation
Number of channel setups max. 14
Number of traces (simultaneous display) vector network analyzer mode no limitation
spectrum analyzer mode 6
Number of markers vector network analyzer mode no limitation
spectrum analyzer mode 16
General data
Operating system Windows 10
Display 10.1" (26.4 cm) WXGA color LCD, multitouch screen
Dimensions (W × H × D) 408 mm × 186 mm × 235 mm (16.06 in × 7.32 in × 9.25 in)
Weight depending on configuration 6 kg to 7.3 kg (13.22 lb to 16 lb)

14
ORDERING INFORMATION
Designation Type Order No.
Base unit
Vector network analyzer, 5 kHz to 3 GHz, two ports, N (f) R&S®ZNL3 1323.0012.03
Vector network analyzer, 5 kHz to 4.5 GHz, two ports, N (f) R&S®ZNL4 1323.0012.04
Vector network analyzer, 5 kHz to 6 GHz, two ports, N (f) R&S®ZNL6 1323.0012.06
Vector network analyzer, 5 kHz to 14 GHz, two ports, N (f) R&S®ZNL14 1323.0012.14
Vector network analyzer, 5 kHz to 20 GHz, two ports, 3.5 mm (m) R&S®ZNL20 1323.0012.20
Hardware options
Spectrum analyzer function for R&S®ZNL3 R&S®ZNL3-B1 1323.1802.02
Spectrum analyzer function for R&S®ZNL4 R&S®ZNL4-B1 1303.8099.02
Spectrum analyzer function for R&S®ZNL6 R&S®ZNL6-B1 1323.2067.02
Spectrum analyzer function for R&S®ZNL14 R&S®ZNL14-B1 1303.8082.02
Spectrum analyzer function for R&S®ZNL20 R&S®ZNL20-B1 1303.8101.02
Extended power range for R&S®ZNL3 R&S®ZNL3-B22 1323.1860.02
Extended power range for R&S®ZNL4 R&S®ZNL4-B22 1303.8118.02
Extended power range for R&S®ZNL6 R&S®ZNL6-B22 1323.2021.02
Extended power range for R&S®ZNL14 R&S®ZNL14-B22 1303.8153.02
Extended power range for R&S®ZNL20 R&S®ZNL20-B22 1303.9089.02
Receiver step attenuator for R&S®ZNL3, port 1 R&S®ZNL3-B31 1323.1848.02
Receiver step attenuator for R&S®ZNL3, port 2 R&S®ZNL3-B32 1323.1854.02
Receiver step attenuator for R&S®ZNL4, port 1 R&S®ZNL4-B31 1303.8124.02
Receiver step attenuator for R&S®ZNL4, port 2 R&S®ZNL4-B32 1303.8130.02
Receiver step attenuator for R&S®ZNL6, port 1 R&S®ZNL6-B31 1323.2038.02
Receiver step attenuator for R&S®ZNL6, port 2 R&S®ZNL6-B32 1323.2044.02
Receiver step attenuator for R&S®ZNL14, port 1 R&S®ZNL14-B31 1303.8160.02
Receiver step attenuator for R&S®ZNL14, port 2 R&S®ZNL14-B32 1303.8176.02
Receiver step attenuator for R&S®ZNL20, port 1 R&S®ZNL20-B31 1303.9095.02
Receiver step attenuator for R&S®ZNL20, port 2 R&S®ZNL20-B32 1303.9108.02
Additional removable PC board with SSD R&S®ZNL-B19 1323.2938.02
OCXO accurate reference frequency R&S®FPL1-B4 1323.1902.02
Additional interfaces R&S®FPL1-B5 1323.1883.02
GPIB interface R&S®FPL1-B10 1323.1890.02
YIG preselector bypass 1), 6) R&S®FPL1-B11 1323.1619.02
DC power supply (12 V/24 V) R&S®FPL1-B30 1323.1877.02
Lithium-ion battery pack R&S®FPL1-B31 1323.1725.02
40 MHz analysis bandwidth 1)
R&S®FPL1-B40 1323.1931.02
Software options
Time domain analysis R&S®ZNL-K2 1323.1819.02
Distance-to-fault measurements R&S®ZNL-K3 1323.1825.02
Independent CW source R&S®ZNL-K14 1303.8182.02
AM/FM/φM analog modulation analysis 1)
R&S®FPL1-K7 1323.1731.02
Measurements with R&S®NRP power sensors 1) R&S®FPL1-K9 1323.1754.02
Noise figure measurements 1), 2) R&S®FPL1-K30 1323.1760.02
Please contact your local
R&S®VSE signal explorer software plus selected options 3)
Rohde & Schwarz sales office.
Recommended extras
Calibration kits
Calibration kit, N (m), 50 Ω, 0 Hz to 18 GHz R&S®ZN-Z170 1328.8163.02
Calibration kit, N (f), 50 Ω, 0 Hz to 18 GHz R&S®ZN-Z170 1328.8163.03
Calibration kit, 3.5 mm (m), 50 Ω, 0 Hz to 26.5 GHz R&S®ZN-Z135 1328.8157.02
Calibration kit, 3.5 mm (f), 50 Ω, 0 Hz to 26.5 GHz R&S®ZN-Z135 1328.8157.03

Rohde & Schwarz R&S®ZNL Vector Network Analyzer  15


Designation Type Order No.
Calibration units
Calibration unit, 1 port, N (f), 2 MHz to 4 GHz R&S®ZN-Z103 1321.1828.02
Calibration unit, 1 port, N (f), 1 MHz to 6 GHz R&S®ZN-Z103 1321.1828.12
Calibration unit, 2 configurable ports, 5 kHz to 4.5 GHz R&S®ZN-ZE104 1350.8040.04
Calibration unit, 2 configurable ports, 5 kHz to 9 GHz R&S®ZN-ZE109 1350.8040.09
Calibration unit, 2 configurable ports, 5 kHz to 18 GHz R&S®ZN-ZE118 1350.8040.18
Calibration unit, 2 configurable ports, 5 kHz to 26.5 GHz R&S®ZN-ZE126 1350.8040.26
Cables
N (m) to N (m), 50 Ω, length: 0.6 m/0.9 m, 0 Hz to 18 GHz R&S®ZV-Z191 1306.4507.24/36
N (m) to 3.5 mm (m), 50 Ω, length: 0.6 m/0.9 m, 0 Hz to 18 GHz R&S®ZV-Z192 1306.4513.24/36
3.5 mm (f) to 3.5 mm (m), 50 Ω, length: 0.6 m/0.9 m, 0 Hz to 26.5 GHz R&S®ZV-Z193 1306.4520.24/36
Active probes
USB-powered adapter, N (m) to probe plug R&S®RT-ZA9 1417.0909.02
Active probe, single-ended, 0 Hz to 3 GHz 1), 4)
R&S®RT-ZS30 1410.4309.02
Active probe, single-ended, 0 Hz to 6 GHz 1), 4) R&S®RT-ZS60 1418.7307.02
Active probe, differential, 0 Hz to 3 GHz 1), 4) R&S®RT-ZD30 1410.4609.02
Active probe, differential, 0 Hz to 4 GHz 1), 4) R&S®RT-ZD40 1410.5205.02
Power rail active probe, 0 Hz to 4 GHz 1), 4) R&S®RT-ZPR40 1800.5406.02
Accessories
Broadband limiter, N (m to f), 50 Ω, 50 MHz to 6 GHz R&S®ZN-B13 1303.7840.02
Smart noise source, 10 MHz to 26.5 GHz 1), 5) R&S®FS-SNS26 1338.8008.26
Protective hard cover R&S®FPL1-Z1 1323.1960.02
Transport bag, with transparent cover R&S®FPL1-Z2 1323.1977.02
Carrying vest holster R&S®FPL1-Z3 1323.1683.02
Spare battery pack R&S®FPL1-Z4 1323.1677.02
Anti-glare film R&S®FPL1-Z5 1323.1690.02
Rackmount kit R&S®FPL1-Z6 1323.1954.02
Power sensors
Thermal power sensor, 0 Hz to 18 GHz, 100 mW R&S®NRP18T 1424.6115.02
Thermal power sensor, 0 Hz to 33 GHz, 100 mW R&S®NRP33T 1424.6138.02
For a list of the R&S®NRP power sensors supported by R&S®FPL1-K9, refer to the R&S®NRP brochure (PD 3606.7147.32).

1)
Requires R&S®ZNLx-B1 hardware option.
2)
Requires R&S®FPL1‑B5 hardware option for noise source control.
3)
For further information on the R&S®VSE vector signal explorer software, see PD 3607.1371.12 and www.rohde-schwarz.com/product/vse.
4)
Requires R&S®RT-ZA9.
5)
Requires R&S®FPL1-K30 software option.
6)
Only available for R&S®ZNL14 and R&S®ZNL20.

Warranty
Base unit 3 years
All other items 1) 1 year
Options
Extended warranty, one year R&S®WE1
Extended warranty, two years R&S®WE2
Extended warranty with calibration coverage, one year R&S®CW1 Please contact your local
Extended warranty with calibration coverage, two years R&S®CW2 ­Rohde & Schwarz sales office.
Extended warranty with accredited calibration coverage, one year R&S®AW1
Extended warranty with accredited calibration coverage, two years R&S®AW2

1)
For options installed, the remaining base unit warranty applies if longer than 1 year. Exception: all batteries have a 1 year warranty.

Rohde & Schwarz R&S®ZNL Vector Network Analyzer 16


FROM PRESALES TO ­SERVICE.
AT YOUR DOORSTEP.
The Rohde & Schwarz network in over 70 countries ensures optimum on-site support by
highly qualified experts.
User risks are reduced to a minimum at all project stages:
► Solution finding/purchase
► Technical startup/application development/integration
► Training
► Operation/calibration/repair

Finland

Norway

Sweden Estonia
Latvia
Denmark Lithuania
United Russian
Kingdom Poland Federation
Netherlands

Belgium Czech Republic


Ukraine
France Austria Hungary
Slovenia Romania
Switzerland

Serbia Bulgaria
Italy
Spain Azerbaijan
Portugal
Greece Turkey

Malta Cyprus
Canada
Cologne Germany

Teisnach
Portland Ottawa Memmingen Kazakhstan
Toronto Mongolia
Azerbaijan
Columbia/Maryland Beijing
USA Japan
Seoul
Los Angeles Islamabad Xi'an South Daejeon Saitama
Dallas Algeria Korea Tokyo
Chengdu Gumi City Osaka
Pakistan China
Monterrey Egypt UAE Shanghai
Saudi Karachi New Delhi Guangzhou Taipei
Mexico Arabia India Taiwan
Shenzhen
Mexico City Oman Kaohsiung
Mumbai Hong
Hyderabad Hanoi
Kong
Vietnam
Ho Chi Philippines
Thailand
Sales locations Bangalore Minh City
Penang
Malaysia
Lead service centers Selangor
Colombia
Singapore
Service centers
Indonesia
Brazil

Rio de Janeiro

São Paulo Australia


South Africa
Uruguay
Chile Sydney
Argentina Melbourne
Canberra

New Zealand

Rohde & Schwarz R&S®ZNL Vector Network Analyzer 17


Rohde & Schwarz
Service that adds value The Rohde & Schwarz technology group is among the trail-
► Worldwide blazers when it comes to paving the way for a safer and
► Local and personalized connected world with its leading solutions in test & measure-
► Customized and flexible ment, technology systems and n ­ etworks & cybersecurity.
► Uncompromising quality
► Long-term dependability Founded more than 85 years ago, the group is a reliable
partner for industry and government customers around
the globe. The independent company is headquartered in
Munich, Germany and has an extensive sales and service
network with locations in more than 70 countries.

www.rohde-schwarz.com

Sustainable product design


► Environmental compatibility and eco-footprint
► Energy efficiency and low emissions
► Longevity and optimized total cost of ownership

Certified Quality Management Certified Environmental Management

ISO 9001 ISO 14001

Rohde & Schwarz training


www.training.rohde-schwarz.com

Rohde & Schwarz customer support


www.rohde-schwarz.com/support

3607107112
3607.1071.12 08.00 PDP/PDW 1 en

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG


R&S® is
Trade a registered
names trademark
are trademarks of of
theRohde & Schwarz GmbH & Co. KG
owners
Trade
PD names are trademarks
3607.1071.12 of the
| Version 08.00 owners
| July 2022 (ja)
PD 3607.1071.12
R&S®ZNL | VersionAnalyzer
Vector Network 08.00 | July 2022 (ja)
R&S®ZNL
Data Vector
without Network
tolerance Analyzer
limits is not binding | Subject to change
Data without
© 2017 - 2022tolerance
Rohde & limits
Schwarzis not
GmbH binding
& Co.| Subject to change
KG | 81671 Munich, Germany
© 2017 - 2022 Rohde & Schwarz GmbH & Co. KG | 81671 Munich, Germany

You might also like