,qvwdoolqj DQG 2shudwlqj, Qvwuxfwlrqv: 1. General Warning
,qvwdoolqj DQG 2shudwlqj, Qvwuxfwlrqv: 1. General Warning
:,1* To see the max. stored temperature; in programming mode it browses the parameter codes or
increases the displayed value. By holding it pressed for 3s the fast freezing cycle is started.
;:/ ;:/ To see the min stored temperature; in programming mode it browses the parameter codes or
decreases the displayed value.
1. GENERAL WARNING
By holding it pressed for 3s the defrost is started.
1.1 PLEASE READ BEFORE USING THIS MANUAL Switch ON and OFF the cold room light.
• This manual is part of the product and should be kept near the instrument for easy and quick reference.
• The instrument shall not be used for purposes different from those described hereunder. It cannot be used By holding it pressed for 3s Energy Saving function is started or stopped.
as a safety device.
• Check the application limits before proceeding.
For XW270L model. Switch ON and OFF the auxiliary output.
1.2 SAFETY PRECAUTIONS For XW271L model. Switch ON and OFF the anti-condensing heater output.
• Check the supply voltage is correct before connecting the instrument.
• Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden Switch ON and OFF the instrument.
temperature changes with high atmospheric humidity to prevent formation of condensation
• Warning: disconnect all electrical connections before any kind of maintenance.
• Fit the probe where it is not accessible by the End User. The instrument must not be opened. KEY COMBINATIONS
• In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.p.A.” (see
address) with a detailed description of the fault.
•
•
Consider the maximum current which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from each other,
+ To lock and unlock the keyboard.
2. GENERAL DESCRIPTION
Models XW270L and XW271L, 38x185 mm format, are microprocessor based controllers suitable for applications
+ To exit the programming mode.
on medium or low temperature refrigerating units. They are provided with six relay outputs to control compressor,
defrost - which can be either electrical or hot gas - the evaporator fans, the lights, the alarm and an auxiliary
output. In XW271L the auxiliary output is configured as anti-condensing heater.
4.1 USE OF LEDS
They are also provided with three NTC probe inputs, one for temperature control, one to control the defrost end Each LED function is described in the following table.
temperature of the evaporator and the third, optional, for the display. There are two digital inputs (free contact) for
the door switch and configurable by parameter. LED MODE Function
The standard TTL output allows the user to connect, by means of a TTL/RS485 external module, a ModBUS- ON The compressor is running
RTU compatible monitoring system and to programme the parameter list with the “Hot Key”.
An optional output for remote display “XW-REP” is available. FLASHING - Programming Phase (flashing with LED )
- Anti-short cycle delay enabled
3. CONTROLLING LOADS ON The fan is running
FLASHING
3.1 THE COMPRESSOR Programming Phase (flashing with LED )
The regulation is performed according to the temperature measured by the thermostat probe with a positive ON The defrost is enabled
differential from the set point: if the temperature increases and reaches set point plus differential the compressor is
started and then turned off when the temperature reaches the set point value again. FLASHING Drip time in progress
In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters “COn”
ON The Fast Freezing cycle is enabled
and “COF”.
ON - ALARM signal
3.2 FAST FREEZING - In “Pr2” indicates that the parameter is also present in “Pr1”
When defrost is not in progress, it can be activated the keypad by holding the 9
key pressed for about 3
ON (Present only in ’XW271L)
The Anti-condensing heater relay (Aux) is ON.
9
seconds. The compressor operates in continuous mode for the time set through the “CCt” parameter. The cycle
can be terminated before the end of the set time using the same activation key, for about 3 seconds.
Function of the LEDs placed on the left top side of buttons:
3.3 DEFROST
BUTTON MODE FUNCTION
Three defrost modes are available through the “tdF” parameter: defrost with electrical heater, hot gas or
SET FLASHING The Set point is displayed and it can be modified
thermostatic defrost. The defrost interval is control by means of parameter “EdF”: (EdF=in) the defrost is made
SET FAST FLASHING The Energy Saving is enabled
every “IdF” time, (EdF=Sd) the interval “IdF” is calculate through Smart Defrost algorithm (only when the
compressor is ON and the evaporator temperature is bigger than “SdF” parameter). DEFROST ON The Manual Defrost is activated
At the end of defrost the drip time is controlled through the “Fdt” parameter. ENERGY SAVING ON The Energy Saving is enabled
LIGHT ON The Light is ON
AUX ON The Auxiliary output is ON (XW270L)
3.4 CONTROL OF EVAPORATOR FANS HEATER ON The Anti-condensing heater is ON (XW271L)
The fan control mode is selected by means of the “FnC” parameter: ON/OFF ON The instrument is OFF
FnC=C-n fans will switch ON and OFF with the compressor and not run during defrost:;
FnC=C-y fans will run continuously, but not during defrost 4.2 HOW TO SEE THE MIN TEMPERATURE
After defrost, there is a timed fan delay allowing for drip time, set by means of the “Fnd” parameter.
FnC=O-n fans will switch ON and OFF with the compressor and run during defrost; 1. 8
Press and release the key.
FnC=O-y fans will run continuously also during defrost 2. The “Lo” message will be displayed followed by the minimum temperature recorded.
An additional parameter “FSt” provides the setting of temperature, detected by the evaporator probe, above which
3. 8
By pressing the key or waiting for 5s the normal display will be restored.
the fans are always OFF. This can be used to make sure circulation of air only if his temperature is lower than set 4.3 HOW TO SEE THE MAX TEMPERATURE
in “FSt”.
1. 9
Press and release the key.
2. The “Hi” message will be displayed followed by the maximum temperature recorded.
3.5 AUXILIARY OUTPUT 3. 9
By pressing the key or waiting for 5s the normal display will be restored.
The auxiliary output is switch ON and OFF by means of the corresponding button on the keyboard.
The auxiliary output of the XW271L model controls the anti-condensing heater and it is automatically activated if 4.4 HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED
the room temperature is lower than the “SAA” parameter.
To reset the stored temperature, when max or min temperature is displayed :
1. Press SET key until “rST” label starts blinking.
4. KEYBOARD
N.B. After the installation RESET the temperature stored .
9 8
2. The SET LED start blinking;
3. To change the Set value push the or arrows within 10s.
4. To memorise the new set point value push the SET key again or wait 10s.
To display and modify target set point; in programming mode it selects a parameter or confirm an
operation.
By holding it pressed for 3s when max or min temperature is displayed it will be erased.
+0.5
-031
EAL = generic alarm;
bAL = serious alarm mode;
PAL = Pressure switch;
dFr = Start defrost;
AUS = Relay AUX actuation; Ø3 x2
Es = Energy Saving;
onF = remote On/OFF.
did Time interval/delay for digital input alarm:(0÷255 min.) Time interval to calculate the number of the XW270L/XW271L MOUNTING
pressure switch activation when I2F=PAL. If I2F=EAL or bAL (external alarms), “did” parameter defines the
time delay between the detection and the successive signalling of the alarm.
SAA Set Point for anti-condensing heater: (-50,0÷110,0°C; -58÷230°F) defines the room temperature
setpoint to switch on the anti-condensing heater.
OTHER
Adr RS485 serial address (1÷247): Identifies the instrument address when connected to a ModBUS
compatible monitoring system.
Rel Release software: (read only) Software version of the microprocessor. 1
Ptb Parameter table: (read only) it shows the original code of the parameter map. 2
Prd Probes display: (read only) display the temperature values of the evaporator probe Pb2 and the auxiliary
probe Pb3.
Pr2 Access to the protected parameter list (read only).
4
3
DIGITAL INPUTS
The Wing series can support up to 2 free contact digital inputs. One is always configured as door switch, the
second is programmable in seven different configurations by the “I2F” parameter.
INSTALLATION AND MOUNTING UPLOAD (FROM THE INSTRUMENT TO THE “HOT KEY”)
Instruments XW270L, XW271L shall be mounted on vertical panel, in a 150x31 mm hole, and fixed using two 1. Turn OFF the instrument by means of the ON/OFF key and remove the TTL serial cable if present; then
9
screws ∅ 3 x 2mm. To obtain an IP65 protection grade use the front panel rubber gasket (mod. RG-L). The turn it ON again.
temperature range allowed for correct operation is 0 - 60 °C. Avoid places subject to strong vibrations, corrosive
gases, excessive dirt or humidity. The same recommendations apply to probes. Let the air circulate by the cooling 2. When the Wing unit is ON, insert the “Hot key” and push key; the "uPL" message appears.
holes. 3. Push “SET” key to start the UPLOAD; the “uPL” message is blinking.
4. Turn OFF the instrument remove the “Hot Key”, plug in the TTL serial cable, then turn it ON again.
CUT OUT At the end of the data transfer phase the instrument displays the following messages:
“end “ for right programming.
“err” for failed programming. In this case push “SET” key if you want to restart the programming again or remove
the not programmed “Hot key”.
ALARM SIGNALS
Message Cause Outputs
“P1” Thermostat probe failure Alarm output ON; Compressor output according to
parameters “COn” and “COF”
“P2” Evaporator probe failure Alarm output ON; Other outputs unchanged
“P3” Auxiliary probe failure Alarm output ON; Other outputs unchanged
“HA” Maximum temperature alarm Alarm output ON; Other outputs unchanged DEFAULT SETTING VALUES
“LA” Minimum temperature alarm Alarm output ON; Other outputs unchanged
“EE” Data or memory failure Alarm output ON; Other outputs unchanged Label Name Range Default Level
“dA” Defrost timeout alarm Alarm output ON; Other outputs unchanged REGULATION °C/°F XW270L XW271L
“dAL” Door switch alarm Alarm output ON; Other outputs unchanged Set Set point LS÷US -5 Pr1 Pr1
“EAL” External alarm Alarm output ON; Other outputs unchanged Hy Differential 0,1÷25,5 °C / 1÷45°F 2 Pr1 Pr1
“BAL” Serious external alarm Alarm output ON; Other outputs OFF LS Minimum set point -50,0°C÷SET / -58°F÷SET -30 Pr2 Pr2
“PAL” Pressure switch alarm Alarm output ON; Other outputs OFF US Maximum set point SET ÷ 110°C / SET ÷ 230°F 20 Pr2 Pr2
The alarm message is displayed until the alarm condition is recovery. OdS Outputs activation delay at start up 0÷255 min. 1 Pr2 Pr2
All the alarm messages are showed alternating with the room temperature except for the “P1” which is flashing. AC Anti-short cycle delay 0÷30 min. 1 Pr1 Pr1
To reset the “EE” alarm and restart the normal functioning press any key, the “rSt” message is displayed for about CCt Compressor ON time during fast freezing 0 ÷ 23h 50 min. 0 Pr2 Pr2
3s. COn Compressor ON time with faulty probe 0÷255 min. 15 Pr2 Pr2
COF Compressor OFF time with faulty probe 0÷255 min. 30 Pr2 Pr2
SILENCING BUZZER / ALARM RELAY OUTPUT DISPLAY
If “tbA = y”, once the alarm signal is detected the buzzer and the relay are is silenced by pressing any key. CF Temperature measurement unit °C ÷ °F °C Pr2 Pr2
If “tbA = n”, only the buzzer is silenced while the alarm relay is on until the alarm condition recovers. rES Resolution (integer/decimal point) in ÷ de de Pr1 Pr1
Lod Local display P1 ÷ 1r2 P1 Pr2 Pr2
“EE” ALARM Red Remote display P1 ÷ 1r2 P1 Pr2 Pr2
The instruments are provided with an internal check for the data integrity. Alarm “EE” flashes when a DEFROST
failure in the memory data occurs. In such cases the alarm output is enabled. tdF Defrost type rE, rT, in rE Pr1 Pr1
EdF Defrost mode In, Sd In Pr2 Pr2
ALARM RECOVERY SdF Set point for SMART DEFROST -30 ÷ +30°C / -22÷+86°F 0 Pr2 Pr2
Probe alarms : “P1” (probe1 faulty), “P2” and “P3”; they automatically stop 10s after the probe restarts normal dtE Defrost termination temperature -50,0÷110°C/ -58÷230°F 8 Pr1 Pr1
operation. Check connections before replacing the probe. (1°Evaporator)
Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat temperature returns to normal IdF Interval between defrost cycles 1÷120h 6 Pr1 Pr1
values or when the defrost starts. MdF (Maximum) length for 1° defrost 0÷255 min. 30 Pr1 Pr1
Door switch alarm “dA” stop as soon as the door is closed.
dFd Displaying during defrost rt, it, SEt, dEF, dEG it Pr2 Pr2
External alarms “EAL”, “BAL” stop as soon as the external digital input is disabled “PAL” alarm is recovered by
switching OFF the instrument. dAd MAX display delay after defrost 0÷255 min. 30 Pr2 Pr2
Fdt Draining time 0÷60 min. 0 Pr2 Pr2
TECHNICAL DATA dPO First defrost after start up n÷ y n Pr2 Pr2
dAF Defrost delay after fast freezing 0 ÷ 23h 50 min. 2 Pr2 Pr2
Housing: self extinguishing ABS.
Case: facia 38x185 mm; depth 76mm FANS
Mounting : panel mounting in a 150x31 mm panel cut-out with two screws. ∅ 3 x 2mm. FnC Fans operating mode C-n, C-y, O-n, O-y O-n Pr2 Pr2
Distance between the holes 165mm Fnd Fans delay after defrost 0÷255 min. 10 Pr2 Pr2
Protection: IP20. FSt Fans stop temperature -50,0÷110°C/ -58÷230°F 2 Pr2 Pr2
Frontal protection: IP65 with frontal gasket mod RG-L. (optional) ALARMS
Connections: Screw terminal block ≤ 2,5 mm2 heat-resistant wiring and 6,3mm Faston ALC Temperature alarms configuration rE÷Ab rE Pr2 Pr2
Power supply: 230Vac or. 110Vac ± 10% ALU MAXIMUM temperature alarm -50,0÷110°C/ -58÷230°F 10 Pr1 Pr1
Power absorption: 7VA max. ALL minimum temperature alarm -50,0÷110°C/ -58÷230°F 10 Pr1 Pr1
Display: 3 digits, red LED, 14,2 mm high. AFH Temperature alarm and fan differential 0,1÷25,5 °C / 1÷45°F 2
Inputs: 3 NTC probes
ALd Temperature alarm delay 0÷255 min. 15 Pr2 Pr2
Digital inputs: 2 free voltage
Relay outputs: Total current on loads MAX. 20A dAO Delay of temperature alarm at start up 0 ÷ 23h 50 min. 1,3 Pr2 Pr2
compressor: relay SPST 20(8) A, 250Vac EdA Alarm delay at the end of defrost 0÷255 min. 30 Pr2 Pr2
light: relay SPST 16(3) A, 250Vac dot Delay of temperature alarm after closing 0÷255 min. 15 Pr2 Pr2
fans: relay SPST 8(3) A, 250Vac the door
defrost: relay SPST 8(3) A, 250Vac dOA Open door alarm delay 0÷255 min. 15 Pr2 Pr2
alarm: SPST relay 8(3) A, 250Vac tBA Alarm relay silencing y÷ n y Pr2 Pr2
auxiliary: SPST relay 16(3) A, 250Vac nPS Pressure switch activation number 0÷15 0 Pr2 Pr2
Other output : alarm buzzer ANALOGUE INPUTS
Serial output : TTL standard Ot Thermostat probe calibration -12,0÷12,0°C / -21÷21°F 0 Pr1 Pr1
Communication protocol: Modbus - RTU OE Evaporator probe calibration -12,0÷12,0°C / -21÷21°F 0 Pr2 Pr2
Data storing: on the non-volatile memory (EEPROM).
O3 Auxiliary probe calibration -12,0÷12,0°C / -21÷21°F 0 Pr2 Pr2
Kind of action: 1B.
P2P Evaporator probe presence n÷ y y Pr2 Pr2
Pollution grade: normal
Software class: A. P3P Auxiliary probe presence n÷ y n Pr2 Pr2
Operating temperature: 0÷60 °C. HES Temperature increase during the Energy -30÷30°C / -22÷86°F 0 Pr2 Pr2
Storage temperature: -25÷60 °C. Saving cycle
Relative humidity: 20÷85% (no condensing) DIGITAL INPUTS
Measuring and regulation range: NTC probe: -40÷110°C (-58÷230°F) Odc Open door control no, Fan, CPr, F_C Fan Pr2 Pr2
Resolution: 0,1 °C or 1°C or 1 °F (selectable). I1P Door switch polarity CL÷OP CL Pr2 Pr2
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit I2P Configurable digital input polarity CL÷OP CL Pr2 Pr2
i2F Digital input configuration EAL, bAL, PAL, dFr, EAL Pr2 Pr2
CONNECTIONS AUS, ES, OnF
dId Digital input alarm delay 0÷255 min. 5 Pr2 Pr2
XW270L/XW271L SAA Set point for anti-condensing heater -50,0÷110°C/ -58÷230°F -20.0 --- Pr2
OTHER
(*) In XW271L, AUX is an anticondensing heater Adr Serial address 0÷247 1 Pr1 Pr1
rEL Software release --- 1.0 Pr2 Pr2
;:/;:/ Ptb Map code --- --- Pr2 Pr2
16A 8A 8A 8A 16A 20A Prd Probes display Pb1÷Pb3 --- Pr2 Pr2
250Vac 250Vac 250Vac 250Vac 250Vac 250Vac MA X Pr2 Access parameter list --- --- Pr2 Pr2
20A
Digital inp.
Room
Common
Door switch
Display
N eutral
AUX ALARM
Line
Def.
Dixell S.p.A. Via dell’Industria, 27 - 32010 Z.I Pieve d’Alpago (BL) ITALY
(*)
Def. Fan Lig ht Comp tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13 - (PDLOGL[HOO#GL[HOOFRP KWWSZZZGL[HOOFRP