Dynex Ves D 03 Specs
Dynex Ves D 03 Specs
D03 Pattern
Directional Control Valves
CONTACT INFORMATION
USA Headquarters
Dynex/Rivett Inc.
770 Capitol Drive
Pewaukee, WI 53072 U.S.A.
Tel: 262-691-2222
FAX: 262-691-0312
E-mail: [email protected]
European Sales
Dynex/Rivett Inc.
Unit C5 Steel Close, Little End Road, Eaton Socon,
Huntingdon, Cambs. PE19 8TT United Kingdom
Tel: +44 (0) 1480 213980
FAX: +44 (0) 1480 405662
E-mail: [email protected]
BROCHURE NOTES:
Consult the Dynex sales department for a review of any application which requires operating above
the rated flows or pressures, or higher than normal operating temperatures.
Specifications shown were in effect when published. Since errors or omissions are possible, contact
your sales representative for the most current specifications before ordering. Dynex reserves the right
to discontinue or change designs at any time without incurring any obligation.
Compact Valves
Control Flow to
15 U.S. gpm (57 L/min)
High performance D03 valves are
rated for 8 U.S. gpm (30 L/min)
nominal and 15 U.S. gpm (57 L/min)
maximum flow, at pressures to
5000 psi (350 bar).
This high pressure and high flow
capability provides great efficiency in
a very compact size.
6500 Series
HIGH EFFICIENCY OPERATION Explosion Proof 6500 Series
Double Solenoid
Large internal flow passages, with
uniform flow areas throughout the
body coring, provide exceptional
efficiency. Typical loop pressure drop
(open center spool) is a low 98 psi at
8 U.S. gpm (7 bar at 30 L/min) nominal 6800 Series 6900 Series
flow (∆P loop = P→A + B →T). Hydraulic Piloted Air Piloted
2000 3000
DC
PRESSURE VALVE
AC PORT BODY
1000 4000
2
D03 PATTERN
3
D03 PATTERN
Performance
BAR PSI
PRESSURE
4000
performance for each spool type. The 250 DE F G
200 3000
letters in the “Flow Curve Reference”
table identify the appropriate curve. 150 2000
100
1000
50
LEVER OPERATED MODELS 0
U.S. GPM 2 4 6 8 10 12 14 16
Most manual models are rated for
15 U.S. gpm (57 L/min) maximum. L/MIN. 10 20 30 40 50 60
The exception is model 613011-D03 FLOW
which is rated for 13 U.S. gpm
(49 L/min) maximum. This model
has a Code 3 internal operator (two
position, detented operation) with
Type 011 spool (tandem center). FLOW CURVE REFERENCE
4
D03 PATTERN
PRESSURE
10 150
G
DETERMINING PRESSURE DROP
125
The curves show resistance to flow 8
for various spool types. The table 100
6
identifies the proper pressure drop 75
curve for each spool and flow path. 4
50
AN EXAMPLE 2 25
Installation
and Dimensions
2.00
(50,8)
.16 (4,1), 1.594
GENERAL VALVE MOUNTING .16 (4,1) DEEP MINIMUM (40,49)
1.30 .19
LOCATING PIN HOLE
(33,0) (4,8)
The mounting surface drawing shows
the minimum flush or raised surface P
required for the N.F.P.A. D03 (CETOP 3) 1.220
pattern. Mounting face must be flat 1.70
B A (30,99)
1.02
within 0.0004 inch/4.0 inches (0,010 (43,2) .20 (25,9)
1.250
(31,75)
(5,1) .61
mm/102 mm) with a surface finish of 32 (15,5)
32 microinch(0,80 µm) AA. (0,80) T
.0004/4.0
.030
Port o-rings are included with all (0,010/102)
.50 (0,76)
.25
valves. Mounting bolts must be .250 (6,35) , 4 PORTS .85
(12,7)
(6,4)
ordered separately; 10-24 U.N.C. (21,6)
#10-24 U.N.C.–2B THREADED
1.19
Threaded x 0.75 inch (19 mm), (30,2) .37 (9,4) DEEP, 4 MOUNTING HOLES
5
D03 PATTERN
SOLENOID MODEL DIMENSIONS #10-24 U.N.C. THREADED x .75 (19,0) LONG MOUNTING BOLTS,
4 REQUIRED; TORQUE: 65 LB • IN ( 7,3 N • M)
1/2-14 N.P.T. STANDARD
ELECTRIC ENTRY, 1 EACH SIDE
Refer to the basic installation drawing MANUAL ACTUATOR PIN SOLENOID A FOR 5.00
TYPE 0, 1, 3, 4, 03,
for typical dimensions common to all 32, 32R, 36 SPOOLS;
(127,0)
SOLENOID B FOR TYPE
D03 valves. 011, 2, 2R SPOOLS SOLENOID B FOR TYPE 0, 1, 3,
4, 03, 32, 32R, 36 SPOOLS;
SOLENOID A FOR TYPE 011,
Dimensions are shown for both A.C. 3.73 2, 2R SPOOLS
(94,7)
and D.C. solenoids; D.C. configuration 2.74
(69,6)
shown printed in gray. .38 1.88
(9,7) (47,8)
Weight (Mass) GRIP
Single Solenoid:
A.C., 3.4 lb (1,5 kg); .94
(23,9)
.13
(3,3) 1.30
.125 (3,18)
LOCATING PIN
.25 1.250 .37
D.C., 3.9 lb (1,8 kg) (6,4) (31,75) (9,4)
1.59
(33,0)
.92 2.51 A.C.
.88 (40,4) (23,4) (63,8)
Double Solenoid: (22,4) CLEARANCE TO
REMOVE COIL
3.53
(89,7)
3.12
(79,2)
D.C.
1.75
A.C., 4.0 lb (1,8 kg); (44,4) 1.68 A.C. 8.54 A.C. SOLENOID
(42,7) (216,9)
D.C., 5.3 lb (2,4 kg) 2.30 D.C. 9.77 D.C. SOLENOID
(58,4) (248,2)
shown) is 8.23 inches (209,9 mm). 3.72 SOLENOID A FOR TYPE SOLENOID B FOR TYPE
(94,5) 0, 1, 3, 4, 03, 32, 32R, 0, 1, 3, 4, 03, 32, 32R
Note that spacer plate, part number 36 SPOOLS 36 SPOOLS
6
D03 PATTERN
Weight (Mass)
1.30
3.2 lb (1,5 kg) (33,0) .37 1.250 .25
.125 (3,18) 1.594
LOCATING PIN .92 (9,4) (31,75) (6,4)
(40,49) (23,4)
3.53 .88
(89,7) (22,4)
4.03 .609 1.75
(102,4) (15,47) (44,4)
5.21
(132,3) #10-24 U.N.C. THREADED x
5.83 WITH HANDLE OFFSET .75 (19,0) LONG MOUNTING BOLTS,
(148,1) 4 REQUIRED;
TORQUE: 65 LB • IN ( 7,3 N • M)
7
D03 PATTERN
6 5 4 0 — D03 — 115/DF — R — ✳ — SL — 1 0
Actuator
1 — Manual Lever
5 — Solenoid Operated Lever Position (Manual Models Only)
8 — Hydraulic Piloted
9 — Air Piloted A12 — 12 o’clock position, on port “A” end of valve
A9 — 9 o’clock position, on port “A” end of valve
A6 — 6 o’clock position, on port “A” end of valve
A3 — 3 o’clock position, on port “A” end of valve
B12 — 12 o’clock position, on port “B” end of valve
Internal Operator B9 — 9 o’clock position, on port “B” end of valve
B6 — 6 o’clock position, on port “B” end of valve
1 — Two Position; Spring Offset (P→B), Actuator B3 — 3 o’clock position, on port “B” end of valve
Offset (P→A)
2 — Two Position; Spring Offset (P→A), Actuator
Offset (P→B)
3 — Two Position; Actuator Offset, Detented for
Non-Manual Actuators➀ Options (Solenoid Models Only)
Three Position; Detented for Manual Lever
4 — Two Position; Spring Centered, Actuator Offset ➁ C — CSA and UL Recognized Coils (Etched with Symbol)➀
5 — Three Position; Spring Centered, Actuator Offset M — Hand Actuated Manual Override ➁
6 — Two Position; Spring Offset, Actuator Centered➁ T — Terminal Strip➁➂
7 — Manual Lever Only; Two Position, Detented CG — Cable Grip, for .38 to .44 inch (9,5 to 11,1 mm) O.D.
machine tool cable➁➂
➀ Only available with Type 0, Type 1 and Type 03 spools. SL — Solenoid Lights (Available 115/DF A.C. Only)➁➂
➁ Not available with Manual Lever Operated valves. HPT — High Pressure Tank Port
2300 psi (160 bar) maximum A.C. models
3000 psi (210 bar) maximum D.C. models
BH3A — 3-pin Connector (N.F.P.A. standard T3.539-1980), for
single solenoid models, on port “A” end of valve➁➂➃
BH3B — 3-pin Connector, for single solenoid models, on port
Spools “B” end of valve➁➂➃
A B A B BH5A — 5-pin Connector, for single or double solenoid models,
0 2➀ on port “A” end of valve➁➂➃
BH5B — 5-pin Connector, for single or double solenoid models,
P T P T
on port “B” end of valve➁➂➃
A B A B
➀ Available with 115/DF solenoids only. For other voltages, consult the
1 2R➀ Dynex sales department
P T P T ➁ Option not available with “EPW” solenoid models.
A B A B ➂ Option not available with “Plug-In-Terminal” solenoid models.
➃ N.F.P.A. standard T3.539-1980; A.N.S.I. standard B93.55M-1981.
3➀ 32➀
P T P T
A B A B
A B A B
STANDARD SOLENOIDS: PLUG-IN TERMINAL SOLENOIDS:➀
24/DF — Dual Frequency, 24/60, 24/50 115/HAC — Dual Frequency, 115/60, 110/50
011➀➁ 36➀ 115/DF — Dual Frequency, 115/60, 110/50 230/HAC — Dual Frequency, 230/60, 220/50
P T P T 230/DF — Dual Frequency, 230/60, 220/50 12/HDC — Direct Current, 12 Volts
A B
460/DF — Dual Frequency, 460/60, 440/50 24/HDC — Direct Current, 24 Volts
12VDC — Direct Current, 12 Volts
03 24VDC — Direct Current, 24 Volts
P T 12VDC EPW — Explosion Proof Solenoids
24VDC EPW — Explosion Proof Solenoids
➀ Not available with Type 3 Internal Operators (except manual 115/60 EPW — Explosion Proof Solenoids
lever models). 110/50 EPW — Explosion Proof Solenoids
➁ Open crossover 220/50 EPW — Explosion Proof Solenoids
For Other Voltages, Consult the Dynex Sales Department