0% found this document useful (0 votes)
60 views2 pages

DS HYX-S (8-12) K-T Datasheet V1.2-202412 EU

Uploaded by

Sandeep Harchand
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views2 pages

DS HYX-S (8-12) K-T Datasheet V1.2-202412 EU

Uploaded by

Sandeep Harchand
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Design and specifications are subject to change without notice.

Version 1.2-202412

STRING INVERTER
HYX-S8K/10K/12K-T

Safe & Reliable


IP66, 1400+ cumulative rigorous tests
PV optimizers compatible, module-level shutdown
Type II DC/AC surge protection, lightning-proof
300m AFCI detection with 0.5s rapid shutdown

Convenient & User-Friendly


Compact and lightweight design, plug-and-play installation
App-based quick setup
Intelligent layout with rapid module-level visualization

Profitable & Efficient


160% PV oversizing for extended output
18A design, ideal for high-power modules
98.5% efficiency with wide MPPT range

Smart & Manageable


Module-level monitoring for precise fault positioning
Intelligent IV diagnostics for precise fault identification
Scenario-based app with real-time energy monitoring

www.hyxipower.com
HYX-S8K/10K/12K-T

Product Model HYX-S8K-T HYX-S10K-T HYX-S12K-T


PV Input
Max. Input Power 12,800W 16,000W 19,200W
Max. Input Voltage 1,100V
Nominal Input Voltage 600V
Start-up Voltage 160V
MPPT Operating Voltage Range 140 - 1,000V
MPPT Full Load Voltage Range 330 - 850V
Max. Input Current Per MPPT 18A
Max. Short-Circuit Current 24A
Number of MPPT 2
Max. Input Number Per MPPT 1/1

AC Output
Nominal Output Power 8,000W 10,000W 12,000W
Max. Apparent Power 8,800VA 11,000VA 13,200VA
Nominal Output Voltage 3L / N / PE, 220 / 380V, 230 / 400V
Nominal AC Grid Frequency 50 / 60Hz

12.2A / 380V 15.2A / 380V 18.2A / 380V


Nominal Output Current
11.5A / 400V 14.4A / 400V 17.3A / 400V

13.5A / 380V 16.9A / 380V 20.1A / 380V


Max. Output Current
12.7A / 400V 15.8A / 400V 19.1A / 400V

Adjustable Power Factor 0.8 leading…0.8 lagging


THDi < 3%

Efficiency
Max. Efficiency 98.5%
European Weighted Efficiency 98.1%
MPPT Efficiency 99.9%

Protection
Active Anti-islanding Protection General Electric Frequency Shift
Residual Current Monitoring Yes
DC Reverse Polarity Protection Yes
DC Switch Yes
AC Short-circuit Protection Yes
AC Overvoltage Protection Yes
AC Overcurrent Protection Yes
DC Surge Protection Type II
AC Surge Protection Type II
Ground Fault Detection Yes
AFCI Yes

General Data
Operating Temperature Range -30 to + 60°C
Relative Operating Humidity 0 - 100 %RH
Operating Altitude 4,000m
Cooling Natural Cooling
Display LED+App
Communication RS485 / 4G / WIFI
Weight 21kg
Dimensions (W*H*D) 522*416*162.5mm
Topology Non-Isolated
Degree of Protection IP66
Overvoltage Level PV II / AC III