Machine Code: M0921: Fuel Level Out Of Range High
Information
Description:
A Code M0921 occurs when the Gateway Controller detects a short to supply voltage or an open on
T770G***A wire (3100 or 3180) for 30 seconds. The Gateway Controller monitors the supply voltage to the Fuel
Level sensor on wire (3100 or 3180). The Gateway Controller supplies the Fuel Level sensor with
S/N: AN8T13024 12 volts on wire (3100 or 3180). If a Code M0921 occurs, the fuel gauge will peg full.
• Manual Identification Possible Cause:
Document Library • Signal wire (3100 or 3180) open or shorted to supply.
Model T770G***A • Ground wire (3110 or 2180) open.
• Fuel Level sensor disconnected.
• Service Letters • Fuel Level sensor.
• Gateway Controller.
• Service Codes • Moisture, corrosion, or pushed back pins in the Gateway Controller connectors, Fuel Level
• Schematics sensor connector, Fuel harness, or the Mainframe wire harness. See Electrical Systems
Connector Maintenance in Technical Information.
• If the code is intermittent and not on at the time of testing, the cause of the code may not be
Maintenance
found at this time. Probable causes may include: loose connections, corrosion, pushed back
Safety
pins, the controller, the wire harness or a combination of these problems. Refer to
Instructions
Troubleshooting Intermittent Electrical Faults Procedures.
• LOADER Safety
Conditions for Code:
Instructions
• Remote Start Tool • Key switch / (run/enter) On.
Technical Conditions for Clearing Code:
Information
• Self resetting.
• Hydrostatic Pump
Calibration Pre-GEN
IV
• Hydrostatic Pump
Calibration GEN IV
• Hydrostatic Pump Instructions are necessary before Never work on a machine with the lift
operating or servicing machine. Read arms up unless the lift arms are
Calibration M-Series and understand the Operation & secured by an approved lift arm
• Actuator Calibration Maintenance Manual, Handbook and support device. Failure to use an
signs (decals) on machine. Follow approved lift arm support device can
Pre-GEN IV warnings and instructions in the allow the lift arms or attachment to fall
manuals when making repairs, and cause injury or death.
• Actuator Calibration adjustments or servicing. Check for W-2059-0598
GEN IV correct function after adjustments,
repairs or service. Untrained operators
• Actuator Calibration and failure to follow instructions can
cause injury or death.
M-Series
W-2003-0199
• Wheel Position
Sensor Calibration
Pre-GEN IV
• Wheel Position
1 of 2 2/1/2022, 7:05 PM
Troubleshooting Chart http://localhost:22005/TroubleshootingChart.aspx?Id=1757
Sensor Calibration
GEN IV
• Connector
Maintenance
Put jackstands under the front axles
• Troubleshooting and rear corners of the frame before
running the engine for service. Failure
Intermittent Electrical to use jackstands can allow the
Faults machine to fall or move and cause
injury or death.
• LOADER Sensor W-2017-0286
Table
Document Library
(All Products) Troubleshooting Procedure:
• All Warnings Note: Key switch / (run/enter) must be Off when connectors are connected or disconnected.
• All Service Codes
Live
• All Schematics Step Action Yes No
Data
• All Service Letters
Repair or
and Service News for With the Fuel Level sensor connected, check signal wire
replace Go to
1 (3100 or 3180) for a short to supply voltage. Does wire
wire Step 2.
Today (3100 or 3180) have a short to supply voltage?
harness.
• All Components
Replace
• Glossary Check signal wire (3100 or 3180) to ground wire (3110 Fuel Go to
2
or 2180) for 12 volts. Is there 12 volts present? Level Step 3.
sensor.
No
problem Repair or
Check signal wire (3100 or 3180) and ground wire (3110 found. replace
3
or 2180) for continuity. Do these wires have continuity? Perform wire
wiggle harness.
test.
BATS v2.3.0.2194 [en-GB]