ALLIANCE Multi-Operator DAS

5W Mid-Power Remote Optic Unit (MROU)


Product Specifications / Parts List

The 5W mid-power MROU features:


The ALLIANCE Release 6 platform is SOLiD’s
multi-operator, neutral host Distributed • Combiners support one or two antenna
Antenna System (DAS) that efficiently delivers ports
wireless RF signals into any indoor or outdoor • Easy install, commissioning, and
location difficult to cover with traditional management
macro networks. • Fan and convection cooled
The Mid-power Remote Optic Unit (MROU) can • Rugged construction: IP66 / NEMA 4
support up to seven bands, each delivering 5W certified
of output power. An Add-on remote unit (AOR) • Up to nine bands on one fiber
is supported for additional RF services. (with Add-on unit)

Version 4.3 – May 2024 ©SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
ALLIANCE DAS 5W MROU Product Data Sheet

Specifications
RF Parameter All Bands
TX LPOI: -10 to +20 dBm. HPOI: +15 to +43 dBm each port
Input Power
RX MROU: -50 dBm max
TX +37 dBm for all bands
Output Power
RX All bands -3 dBm ± 0.5 dB (except 2500TDD -23 dBm ± 2 dB)
TX 57dB max for all band
System Gain
RX All bands 47 dB max (except 27 dB for 2500TDD); 25 dB gain control at remote all bands
Spurious Emissions Maximum Intermodulation Distortion. TX: ≤ -13 dBm @ 9kHz to 5GHz
Nominal Impedance 50 Ohm
VSWR 1.66:1 typical, 1.8:1 max at each band In / Out ports
NOTES: TX Input power refers to the DAS headend.
TX Output power is measured at the antenna port. TX and RX Output power is ± 0.5dB.
Additional gain control available at head end including uplink gain control.
See the AOR data sheet for VHF/UHF specifications.

1900 2100
700LTE+ 800/ 2300 2500TDD
RF Parameter 600 MHz PCS AWS
Band 14 850 Cell WCS (Full Band)
(Extended) (Extended)
NF UL (typical) 4.5 dB 3.5 dB 2.9 dB 4 dB 3.4 dB 5 dB 5.2 dB
NF UL (max) 5.0 dB 4.2 dB 3.4 dB 4.5 dB 3.9 dB 5.4 dB 5.8 dB
IIP3 UL (typical) -23.5 dBm -21.2 dBm -21.4 dBm -19.8 dBm -23.2 dBm -20.3 dBm -20.8 dBm
IIP3 UL (max) -24.0 dBm -21.7 dBm -21.9 dBm -20.3 dBm -23.7 dBm -20.8 dBm -21.3 dBm
EVM DL (typical) 1.6% 1.8% 1.8% 1.9% 1.8% 1.3% 2.0%
EVM DL (max) 2.0% 2.2% 2.2% 2.3% 2.2% 1.6% 2.5%
Ripple DL (typical) 3.5 dB 1.9 dB 2.7 dB 1.6 dB 1.6 dB 1.6 dB 5.2 dB
Ripple DL (max) 4 dB 4 dB 4 dB 4 dB 4 dB 3 dB 5 dB
Downlink (DL) 617-652 729-768 862-894 1930-2020 2110-2200 2350-2360 2496.8-2690
699-716
Uplink (UL) 663-698 817-849 1850-1915 1695-1780 2305-2315 2496.8-2690
777-798
NOTES: NF (noise figure) represents system noise tested with one remote connected. Add 2 dB to NF when using Optical
Expansion Unit (OEU or iOEU) or 1-port optic module. EVM performance includes 0.7% error from signal source.
NF, IIP3 and EVM specs are measured with 0 dB attenuation.

Power 700LTE+ 800/ 1900 2100 2300 2500


600 MHz
Consumption (Max) Band 14 850Cell PCS AWS WCS FB
5W MRDU 60W 50W 48W 59W 62W 47W 74W
MROU Chassis RCPU, RPSU, R-Optic = 16W
NOTES: For total power, add the power consumption of the included MRDU’s to the chassis’ power consumption.

Optical Specification
Wavelength Tx: 1550 nm; Rx: 1310 nm
Loss 4-port optic module: 5 dBo max.; 1-port optic module: 10 dBo max.

Version 4.3 – May 2024 ©SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
ALLIANCE DAS 5W MROU Product Data Sheet

Mechanical Specification
Mounting Type Wall or rack (fits standard 19” rack with bracket)
Antenna Connectors 7/16 DIN female
External Alarm Interface 5-Pin connector on bottom panel
Optical Connector SC / APC, Step Ferrule, Waterproof, Single Mode Fiber
Monitoring Port - 40 dB (±3 dB), SMA female, TX output only, located on combiner unit
Craft Port Serial interface RS-232 9-pin D-sub male
Dimensions (WxHxD) 12.6” x 45.9” x 10.2” (320 x 1165 x 260 mm) including wall mount bracket
Weight 137 lbs. (62 kg) max with 6 MRDUs
MTBF 8.96 Years (worst case, fully loaded unit)
Ingress Protection IP66, NEMA 4
Operating Environment Temp: -13 to 131°F / -25 to +55°C. Humidity: 0% to 90% Non-condensing

Regulatory Specification
Type Approval FCC, IC, FCC Part 15 Subpart B, Class A
Safety NRTL Certified
This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This product conforms to
FDA/CDRH
all applicable standards of 21 CFR Chapter 1, Subchapter J, Part 1040.

Overview
SOLiD’s 5W Mid-power Remote Optic Unit (MROU) can be mixed with all other
ALLIANCE remote units in a single system all driven by a common head end.

This highly efficient, small footprint unit can support up to seven frequency bands.
An Add-on remote unit (AOR) can also be connected to support VHF/UHF.

The MROU enclosure incorporates a rugged, but compact NEMA 4 design. Units
can be rack or wall mounted, indoors or outdoors. A fan unit at the bottom of the
enclosure comes installed with base models. An external alarm port on the bottom
of the enclosure can accept input alarms from connected equipment like battery
backup systems.

Combiner units support one- or two-port antenna configurations. A dual fan unit is
available for high-temp deployments.

Unit Name Unit Description


5W Remote Optic Unit (MROU) Enclosure including RCPU, RPSU_AC or DC, Multiplexer, R-Optic
Add-on Remote (AOR) An optional add-on enclosure (not shown in figure above), AC or DC power
Remote Power Supply Unit (RPSU) AC: 100 to 240V. DC: -40.8 to -57.6V
Remote Central Processor Unit (RCPU) Controls and monitors signals for each unit
Mid-power Remote Drive Unit (MRDU) Filters and amplifies downlink / uplink signals
Remote Optic Module (R-Optic) Converts downlink optical signals to RF and uplink RF signals to optical
Combiner Combines downlink signals and separates uplink signals for each band

Version 4.3 – May 2024 ©SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com
ALLIANCE DAS 5W MROU Product Data Sheet

External Fan Unit


Blows air across heatsink fins to promote cooling. Fan comes installed with
standard models – MROU_C_MF_AC_CU8 and MROU_C_MF_DC_CU8 – but can
also be added to any model.

Parts List
Part Number 5W MROU / MRDU / Combiners
MROU_C_MF_AC_CU8 5 WATT Remote Optical Unit Chassis - AC Power with MROU_CU8, Fan Included
MROU_C_MF_DC_CU8 5 WATT Remote Optical Unit Chassis - DC Power with MROU_CU8, Fan Included
MROU_B Blank Amplifier Module for 5W MROU
MRDU_600_700LTE_FN 5 WATT 600 MHz & 700MHz Amplifier Module (Includes Band 14)
MRDU_800I_850C 5 WATT 800MHz & 850MHz Amplifier Module
MRDU_1900P_E 5 WATT 1900MHz Amplifier Module, Extended Band
MRDU_AWS13_B66B70 5 WATT 2100MHz Amplifier Module (AWS1+3) Extended Band
MRDU_2300_WCS 5 WATT 2300MHz WCS Amplifier Module
MRDU_2500_FB_TDD_R 5 WATT 2500 MHz TDD Amplifier Module, 194MHz Contiguous, LTE + NR
MROU_CU8 5 WATT Combiner Unit, 600/700LTE+FN, 850IC, PCS, AWS13, 2300, 2500
CBL_MAOR_ALM 5 WATT Alarm Cable MROU-to-AOR cable with external alarm input pigtail
CBL_MROU_ALM 5 WATT Alarm Cable MROU cable with external alarm input pigtail
ADP_DIN_N_BH Adapter, DIN Jack to N Jack, Bulkhead
External Fan-Tray. Fan comes installed with standard models. – MROU_C_MF_AC_CU8
MROU_FAN_TRAY
and MROU_C_MF_DC_CU8 – but can also be added to any model.

Additional information is available in the following documents, available from the SOLiD Support website.
ALLIANCE REL6 - Mid Power Remote (MROU) - Operations & Install Guide
SOLiD Tech Note – MROU Fan Unit Installation
SOLiD Data Sheet – ALLIANCE MTBF Specification

Version 4.3 – May 2024 ©SOLiD. All Rights Reserved. Confidential & Proprietary. www.solid.com

You might also like