The document provides detailed specifications for a diesel generating set with a 1500 rpm, three-phase output at 50Hz and 400V. It includes information on standard equipment, engine and alternator specifications, control systems, and optional features available for customization. The generating set is compliant with various CE marking standards and is designed for reliable operation in various environments.

Uploaded by

dingener1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views9 pages

19642-GE CU 030 - 027 PROpiu011-en

The document provides detailed specifications for a diesel generating set with a 1500 rpm, three-phase output at 50Hz and 400V. It includes information on standard equipment, engine and alternator specifications, control systems, and optional features available for customization. The generating set is compliant with various CE marking standards and is designed for reliable operation in various environments.

Uploaded by

dingener1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Generating Set

PROFESSIONAL - Diesel

GE.CU.030/027.PRO+011
1500 rpm - Threephase - 50Hz - 400V
Multifunction panel without switching on board

Image for demonstration purposes

Standard equipment

Canopy Soundproofing Engine


Removable soundproof canopy High coolant temperature and low oil pressure shutdown
Painting canopy (RAL) in galvanized sheet steel system
Soundproofing with class 1 polyester material Engine liquids (oil and antifreeze)
Handles with key lock and automatic closing Tropicalized radiator
Inspection doors for controls and maintenance Rotating parts protection
Inspection doors with hermetic gasket
Alternator
Exhaust AVR Automatic Voltage Regulator
Exhaust rain cap Impregnation for marine environment
Insulated exhaust pipes IP23
Internal residential muffler
Panel & connection
Fuel Supply Emergency Stop button
Single wall daily tank with bunded base Protection by controller
Automatic shutdown system for low fuel level Tamperproof panel IP55
Fuel gauge Cable output from the bottom
IP44 wiring
Start-up battery (pre-charged)
Handling Grounding point
n.4 lifting hooks integrated into the bearing structure
Loadable side by side for truck transportation Data and technical specifications are subject to change in order to update or improve the products.
Documentation
CE conformity declaration
Base Frame User and Maintenance manual
Anti-vibrating mounting pads Wirings diagrams
Anti pollution Bunded base
Normatives
All Generating sets are compliant to CE Marking
2014/30/UE Electromagnetic compatibility
2000/14/CE Noise Emission for outdoor use
Factory-designed systems built according to ISO 9001:2015
CEI EN 60204-1:2018 - Electrical equipment of machines

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 1/9
GE.CU.030/027.ST.PRO+011

Primary data

General Information
Speed RPM 1500

Frequency Hz 50

PRP KVA 25

PRP - Prime power KW 20,0

LTP - Standby power KVA 27,5

LTP - Standby power KW 22,0

Standard Voltage V 400/230

Current A 36,13

Voltage for current calculation V 400

COSFI 0,8 0,8

General electrical protection


Circuit-breaker rated current A 40

Type Magnetothermal switch on panel board

Circuit-breaker poles N 4P

Optional/notes circuit-breaker Opening coil

Noise level +/- 3dB(A)


LWA dB(A) 90

Sound pressure level @ 7 mt dB(A) 65

Sound pressure level @ 1 mt dB(A) 74

Fuel Consumption
TYPE Diesel

Standard Fuel Tank capacity lt 90

Autonomy @ 75% load h 19

Fuel consumption at 100% load lt/h 6

Fuel consumption at 75% load lt/h 4,8


Data and technical specifications are subject to change in order to update or improve the products.
Fuel consumption at 50% load lt/h 3,5

General data
Rated capacity Ah 1x100

Auxiliary Voltage V 12

Exhaust gas temperature °C 660

Combustion air flow l/s 38,8

Cooling fan airflow mc/s 1,6

Exhaust diameter mm 50

Weight and Dimensions


Dimensions (L x w x h) cm 188x92x130

Weight with liquids (excluding optionals and fuel) Kg (+/-3%) 771

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 2/9
GE.CU.030/027.ST.PRO+011

Engine
Factory Cummins

Model X2.5G2

Emissions stage Stage 0

Speed governor Mechanic

Radiator °C 50

Cooling Tipo liquid (water + 50% Paraflu11)

Active net power Kwm 23

Nominal net power CV 31,3

Cycle Tipo 4 strokes

Injection Tipo Direct

Aspiration Tipo Natural

Numbers of cylinders N 3

Cylinders arrangement L

Bore mm 91

Stroke mm 127

Total displacement lt 2,477

Engine oil features 15W40-API CI-4/CH-4 ACEA E5-E7

Total oil capacity lt 8

Total coolant capacity lt 10

Alternator
* May vary based on stock availability. However, a primary brand will be used.
Factory Stamford

Model S0L2-M1

Single-phase Range KVA 25

Voltage Regulator (voltage accuracy) +/- % 1

Poles N° 4

Phases N° 3+N

Standard windings connection Star Series

Stator/rotor impregnation H (Outdoor Temp 40°C)

Data and technical specifications are subject to change in order to update or improve the products.
Efficiency % 87,2

Engine coupling Elastic disk

Short circuit current >= 300% (3In)

Protection degree IP 23

Cooling system Self ventilating

Maxium overspeed rpm 2250

Waveform distortion % <5

Exciter Diode bridge

Standard operating environmental conditions


Ambient temperature °C 25

Relative Humidity % 30

Max altitude mt 1000

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 3/9
GE.CU.030/027.ST.PRO+011
Control Systems on board QLE-B-SC-3F-4P-63-O1

QLE Multifunction panel without switching on board


The QLE command and control panel offers outstanding protection, monitoring and control for small and middle size generator sets.Elcos’s control module MC2
Plus offers advanced features to meet the most demanding on-site application. Elcos’s control module MC2 Plus is designed for offer an easy user interface.
Variant without transfer switch. The panel directly manages the QLTS and QC panels. The output line is protected by a magnetothermic breaker with opening coil.
The overload and short-circuit protection is managed by the control board.

Mechanical features
Protection degree IP 55

Battery charger
Model ELCOS - CB1

Maximum output current A 2,5

Output DC voltage (selectable) Vdc 12-24

Input AC voltage (selectable) Vac 220-260

Frequency Hz 50-60

Data Communication

Data and technical specifications are subject to change in order to update or improve the products.
Data connection port RS-485

Communication protocol Mod-bus RTU-8N1

Remotable functions in terminal box


GS start Genset contactor close/open command (1)
Mains contactor close/open command (2) Remote horn - DC output
Programmable output - Volt free output

(1) Ready to load function (ARS mode without QC or QLTS panel)(1) Genset contactor open and close command (AMF mode with QC or QLTS panel)(2) Mains
contactor open and close command (AMF mode with QC or QLTS panel)

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 4/9
GE.CU.030/027.ST.PRO+011

Control Module

Model MC2 Plus

Operating mode AMF - ARS

Specifics

Applications EQUIPMENT VISUALIZATIONS ON CONTROL


Emergency to the Mains Microprocessor Logic MODULE/DISPLAY
Stand-alone Back-lit display Pre-alarms
Construction site/Rental Programmable from display Alarms
Self-production 16 event log Engine measures
Icons management Alternator measures
ENGINE MEASURES STOP button Operating mode
Fuel tank level % START button Genset status
Engine oil pressure BAR (1) TEST button Genset contactor status
Engine Coolant temperature °C (1) Reset alarm button Glow plugs status
Total run time Alarm mute button
Battery voltage CONTROL MODULE FUNCTIONS
Start-ups counter PRE-ALARMS/ ALARMS Remote Start and Stop
Engine speed Common Alarm Manual Start and stop
Fuel reserve (pre-alarm) Emergency stop button on panel board
ALTERNATOR MEASURES Low fuel level (alarm) Remote emergency stop
Generator Voltage L1, L2, L3 Charge alternator failed (dinamo) Remote test on load
Generator Voltage L1-N, L2-N, L3-N Low oil pressure (alarm) Scheduled start-ups
Generator frequency Oil sensor failed (alarm) MODBUS commands (Start, Stop, Reset, Test)
Generator current L1, L2, L3 High coolant temperature (alarm)
Generator Apparent Power kVA Low water level (1)
Generator Active Power kW Water in fuel (1)
Battery undervoltage
COMMUNICATION PORTS
Battery overvoltage
Can-bus port
GS failure to start
RS485 port with Mod-bus RTU communication
GS failure to stop
USB port for parameters saving and firmware
Can-bus Failure
update
No Can-bus communication
Genset overload L1, L2, L3 phases
Genset short circuit
Genset overvoltage
Genset undervoltage
Genset high frequency
Genset low frequency
overspeed
Earth fault (alarm)
Maintenance request
Emergency button pressed
Remote emergency active
Genset negative phase sequence

Data and technical specifications are subject to change in order to update or improve the products.
Elcos MC2 control module is designed for diesel
generating sets. It offers outstanding protection, monitoring and control for small and middle size generator sets.

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 5/9
GE.CU.030/027.ST.PRO+011
AAABBB

OPTIONAL

Fuel Supply

O.G-ACO-AT-CI-01 External tank connections for supply only from external tank (g without tank) GE 10/100

O.G-ACO-BT-P1700-400 400 Lt Oversized Fuel Tank on board for BF/PRO (10/20 kVA), (Increased weight and size)

Batteries

O.G-BAT-BAE-01 Maintenance free high efficiency starter batteries (10/40 kVA)

O.G-BAT-STB-01 Battery isolator lockable (10/100 kVA)

Canopy

O.G-COF-PV-01 Lift off doors kit (10/100 kVA) for SS and PRO version

Electrical on board

O.G-USP-32A5P Output power socket 32A EC 5P (15/20 kVA) for Gen Sets SS Version +011

Additional price for 230V minimum voltage coil on the modular main switch inside the
O.Q-QBM-BMIN-230V-01
control panel (check feasibility)

Permanent insulation controller for IT networks up to 230V / 400V. BENDER IR423-D4-1.


O.Q-QBM-CPI-BEN-01
Adjustable threshold 10 ÷ 300 kohm. (2 DIN rail modules - check feasibility)

Adjustable differential protection only for MC2-PLUS controller for Gen Sets 10/500 kVA
O.Q-QLE-K-DIF-M3
(+011 variant)

Data and technical specifications are subject to change in order to update or improve the products.
O.Q-QLE-QBM-COM-AMF25 Additional price for QBM COMAP AMF25 panel replacing the standard QLE-A.

O.Q-QLE-QBM-DSE-7320 Additional price for QBM DSE7320 panel replacing the standard QLE-A.

O.Q-QLE-QPE-MC4 Additional price for QPE-C panel with MC4 replacing the standard QLE-A.

GE main switch STATUS contact wired to terminal board inside the QPE panel on board
O.Q-QPE-INT-CST-01
generator (10 / 40KVA) (no variant +10)

Engine

O.G-MOT-K-40C-01 Engine liquids suitable for -40°C ambient temperature for Gen Sets 10/40 kVA

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 6/9
GE.CU.030/027.ST.PRO+011

O.G-MOT-PO-01 Oil change pump for Gen Sets 10/100 kVA

Engine pre-heater 230V with thermostat on board for Gen Sets 10/100 kVA + 130/500 PRO
O.G-MOT-SC-AC-EL-01
version

O.G-MOT-SC-AC-EL-02 Super hot engine heater 230V with thermostat on board for Gen Sets 10/100 kVA

ATS Panels

Wall-mounted ATS switching panel 60A 4P (40 kVA 400V - 20 kVA 230V) Dim. 40 x 16 x 40 cm
QLTS.060A
- 12 kg.

Exhaust

O.G-SCA-KS-50 Exhaust flex pipe for drainage (length 3 mt.)

Test

FAT - Factory Acceptance Test for single Gen Set from 10 to 100 kVA according to our
MS.CP-LT-01
standard procedures in Elcos factory (max 2 hours - max 4 people - max 1 hour of operation)

FAT - Factory Acceptance Test for single custom Gen Set from 10 to 100 kVA max 4
MS.CP-SP-01 operating hours or parallel system up to 4 units for 1 operating hour, in Elcos factory (max 4
hours - max 4 people )

FAT - Factory Acceptance Test for single Gen Set from 10 to 100 kVA according to our
MS.CP-ST-01
standard procedures in Elcos factory (max 4 hours - max 4 people - max 2 hour of operation)

Vari

Round earth spike, diam. 20 mm, height 1.5mt, galvanized, complete with clamp and 3m
O.G-VAR-PUN-TER-01
yellow/green cable model FS17 1x35mm² with cable lugs.

Cross-shaped earth spike, height 1.5mt, galvanized, complete with clamp and 3m
O.G-VAR-PUN-TER-02
yellow/green cable model FS17 1x35mm² with cable lugs.

Data and technical specifications are subject to change in order to update or improve the products.

PRP LTP
Engines of this rating provide unlimited hours of usage in a variable load Limited-time running power is defined as the maximum power available, under the
application. The average load factor should not exceed 70% of the engine's prime agreed operating conditions, for which the generating set is capable of delivering
power rating with a maximum number of 500 operational hours at 100% prime for up to 500h of operation per year with the maintenance intervals. The overload is
power rating. An overload capability of 10% is available, however, is limited to a not allowed.
period of 1 in every 12 hours

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 7/9
GE.CU.030/027.ST.PRO+011

Sheet: PRO2000 PRO Exhaust side: - Type: STANDARD Rev: 00 Last Update: 04-02-2020 Page 1/2

OVERALL DIMENSIONS [mm]


REAR VIEW LEFT SIDE VIEW

830 Exhaust ∅50


Control Panel 1343

Air Intake Grill


1305

1305
1100

1445
920 1880 Refuelling
(internal)

FRONT VIEW RIGHT SIDE VIEW

Lifting Hook
830

External fuel Refilling (Optional)


920 1880 [ IN 1/2" - OUT 1,1/4" ]

3D VIEW TOP VIEW

Right

Data and technical specifications are subject to change in order to update or improve the products.
External fuel Refilling (Optional)
[ IN 1/2" - OUT 1,1/4" ]
120
Power Cables Output
150

(See Bottom View)


Front

Rear
592
150

Control Panel
1880
Refuelling
Air Expulsion Grill (internal)

Left
IMPORTANT: 1) Form and dimension refer to the generating set on catalogue
2) Form and dimension are subject to change in order to update or improve the products
3) This document can not be copied or trasmitted without ELCOS S.r.l. approval

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 8/9
GE.CU.030/027.ST.PRO+011

Sheet: PRO2000 PRO Exhaust side: Type: STANDARD Rev: 00 Last Update: 04-02-2020 Page 2/2

3D BOTTOM VIEW BOTTOM VIEW

Left

115 1330 115

Air Intake Grill

Front

Rear
Power Cables Output
Fixing Holes

Right

DIMENSIONS WITH OPEN DOORS [mm]


Right

2315

160
1375

137
80
1000
Front

Rear
1375

Data and technical specifications are subject to change in order to update or improve the products.

Left

Note: With Lifting-Off Door Solution consider only canopy dimensions.


(Models with "Control Panel" behind rear door will mount a special cover to protect it)

VENTILATION OF THE ROOM


The windows area in the generating set room needs to be (recommended):
Aspiration: 0.35 m2
Expulsion: 0.25 m2
ATTENTION: for a correct ventilation the expulsion air and the exaust gas needs to be conveyed in the open-air

IMPORTANT: 1) Form and dimension refer to the generating set on catalogue


2) Form and dimension are subject to change in order to update or improve the products
3) This document can not be copied or trasmitted without ELCOS S.r.l. approval

Elcos srl - S.S. 234 Km 58,25 Grumello Cremonese (CR) Italy tel. +39 0372 72330 fax. +39 0372 7233220 - www.elcos.net - [email protected] 9/9