0% found this document useful (0 votes)
7 views4 pages

MITSUBISHI 2500 kVA DATABLAD

The Mitsubishi 2500 kVA generator offers standby power of 2529 kVA and prime power of 2284 kVA, with specifications for engine and alternator provided. It features a robust cooling system, control panel with advanced monitoring capabilities, and various optional equipment for customization. The generator complies with multiple international standards, ensuring reliability and efficiency in power generation.

Uploaded by

shodirul ilmi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views4 pages

MITSUBISHI 2500 kVA DATABLAD

The Mitsubishi 2500 kVA generator offers standby power of 2529 kVA and prime power of 2284 kVA, with specifications for engine and alternator provided. It features a robust cooling system, control panel with advanced monitoring capabilities, and various optional equipment for customization. The generator complies with multiple international standards, ensuring reliability and efficiency in power generation.

Uploaded by

shodirul ilmi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Mitsubishi 2500 kVA

Output Power

Standby Power (ESP) kVA 2529


kW 2023
Prime Power (PRP) kVA 2284
kW 1827

Size Wx L x H Weight Fuel Tank Noise dB(A)


(mm) (kg) (lt) @ 7m
Canopied TBAxTBAxTBA TBA TBA TBA
Open Skid 2390x6150x3220 TBA 3500 N/A

Continuous Power Standby Power Prime Power


The maximum power which a generating The max power available during a The maximum power which a generating
set is capable of delivering continuously variable electrical power sequence, set is capable of delivering continuously
whilst supplying a constant electrical load. under the stated operating conditions, for whilst supplying a variable electrical load.
Average load can be 100%. The which a generating set is capable of Average load should be 70%. The
generator must not be overloaded. delivering in the event of a utility power generator can be overloaded 10% for 1
outage or under test conditions for up to hour per 12 hrs.
200 hrs of operation per year under
average of 70% load. Overloading isn’t
permissible.

+45 64 41 59 02 [email protected] www.generator.dk


Mitsubishi 2500 kVA

Engine
Manufacturer MITSUBISHI
Model S16R2-PTAW
Cylinder Configuration V TYPE
No of Cylinders 16
Displacement lt 79,9
Stroke mm 220
Bore mm 170
Compression Ratio 14,0:1
Aspiration Turbocharged and Aircooler (Fresh water to
cooler)
Governor Type ELECTRONIC
Cooling System WATER
Coolant Capacity lt 500
Lubrication Oil Capacity lt 260
Electrical System VDC 24
Speed / Frequency 50 Hz rpm 1500 rpm / 50 Hz
Engine Gross Power (Standby 50 Hz) kW 2167
Fuel Consumption %110 ESP 50 Hz lt/h TBA
Fuel Consumption %100 PRP 50 Hz lt/h TBA
Fuel Consumption %75 PRP 50 Hz lt/h TBA
Fuel Consumption %50 PRP 50 Hz lt/h TBA
Exhaust Outlet Temperature 50 Hz °C 524
Exhaust Gas Flow 50 Hz m3/min 474
Combustion Air Flow 50 Hz m3/min 179
Cooling Air Flow 50 Hz m3/min 2316

Alternator
Manufacturer LEROY-SOMER
Model LSA 52.3 L9
No of Phases 3
Power Factor 0,8
No of Bearings SINGLE
No of Poles 4
No of Leads 6
Voltage Regulation (Steady State) ± %0,5
Insulation Class H
Degree of Protection IP 23
Excitation System AVR (Automatic Voltage Regulator);
Brushless
Connection Type STAR
Total Harmonic Content (No Load) < %4
Frequency Hz 50
Voltage Output 50 Hz VAC 230 / 400
Rated Power (Standby) 400_50 Hz kVA 2596
Efficiency (4/4_400 V_50 Hz) % 96,2

+45 64 41 59 02 [email protected] www.generator.dk


Mitsubishi 2500 kVA

Standard Equipments
Engine
In Teksan generator sets, leading engine brands that have state of the art
technology and have compliance with ISO 8528, ISO 3046, BS 5514,
DIN 6271 standarts, are being used. These engines with low fuel
consumption, provide accurate speed setting and order, mount to the fuel
pump, also have mechanic or electronic type governors.
Alternator
In products Teksan produced, leading alternator brands of the world that
have state of the art technology, high quality, productivity and durability,
are being used. All alternators, which pass necessary test process and
found appropriate according to EC 60034-1; CEI EN 60034-1; BS 4999- Canopy Features
5000; VDE 0530, NF 51- 100,111; OVE M-10, NEMA MG 1.22.
standarts, have bearing system that does not need maintenance, with TEKSAN Standard Canopies' default features are as follows;
electronic type voltage regulator providing voltage setting. ■ Compatible with 2000/14/EC directives, certified noise emission level,
■ 2 or 4 points transport possibility according to cabin size,
Control Panel ■ Hidden exhaust inside the canopy,
Standard control panel, that is used in Teksan generator sets, ensures ■ Emergency stop button located on the canopy,
comfortable and safe usage. All measured and statistical parameters, ■ Improved air suction channel to ensure homogenous cooling in the canopy,
operating modes, notice and alarms and condition of generator, are ■ Radiator air outlet and exhaust with designed towards above,
monitored easily from the control panel. On the front of the panel’s metal ■ Lid on cab that provides to be filled up water and antifreeze easily to the
body has electronic control module and the emergency stop button and radiator,
the panel’s metal body is made of steel sheet and is painted with ■ Amplified paint system against corrosion and rust,
electrostatic powder paint. ■ Improved performance in terms of sound insulation,
Teksan offers panel design and solutions that comply with special ■ Demounted parts that make transportation and maintenance easier,
requirements of customers as well as quality standard panels. As well as the standard range of canopies, TEKSAN can also design tailormade
canopies with specific sound level or size upon customer requests.
Chassis and Fuel Tank
Chassis is manufactured from steel that has features and durability for
carrying burden of generator set. Thanks to its rigid structural design Optional Equipments
and anti-vibration mounts, it reduces vibration level to minimum. All
Some Optional Equipments that Teksan provides with Generator Sets;
chassis contain lifting lugs. Apart from chassises that are produce by ■ Medium voltage alternator,
Teksan, special solutions that design in accordance with customer ■ Remote radiator applications,
desires, make transportation and positioning easier. ■ Automatic fuel filling system,
In less than 1600 kVA power generator sets, fuel tank is produced integratedly to ■ Fuel tank, oil pan, dashboard, alternator, coil heaters,
the chassis. In more than 1600 kVA power generator sets, rectangular type fuel ■ Alternator with double AVR and PMG,
tank is provided with generator set seperately. In all types of fuel tank have its ■ Synchronization systems,
level and indicator. ■ The generator output breaker,
■ Grid-generator transfer switches,
Cooling System ■ Accordance with the specific volume of demand-insulated cabins,
System, that consists of quality industrial - type radiator, expansion tank ■ Seismic solutions,
and cooler fan, keeps the temprature of generator set’s equipments ■ Trailer,
constant at a proper level. ■ Remote monitoring.

+45 64 41 59 02 [email protected] www.generator.dk


Mitsubishi 2500 kVA

Control Panel Features-TJ 509-T


■ The TJ-509T is a next generation genset control unit combining multi-
functionality and wide communication possibilities together with a reliable and
low cost design.
■ The unit complies and mostly exceeds world’s tightest safety, EMC, vibration
and environmental standards for the industrial category.
■ Software features are complete with easy firmware upgrade process through
USB port. The Windows based PC software allows monitoring and
programming through USB, RS-485, Ethernet and GPRS.
■ The PC and server based Rainbow Scada software allows monitoring and
control of an unlimited number of gensets from a single central location.

Functions Topologies
■ AMF unit with uninterrupted transfer
■ ATS unit with uninterrupted transfer ■ 2 phase 3 wires, L1-L2
■ Remote start controller ■ 2 phase 3 wires, L1-L3
■ Manual start controller ■ 3 phase 3 wires, 3 CTs
■ Engine controller ■ 3 phase 3 wires, 2 CTs (L1-L2)
■ Remote display & control unit ■ 3 phase 3 wires, 2 CTs (L1-L3)
■ Waveform display of V & I ■ 3 phase 4 wires, star
■ Harmonic analysis of V & I ■ 3 phase 4 wires, delta
■ CTs at genset or load side ■ 1 phase 2 wires

Communications
■ SM-GPRS
■ Web monitoring
■ Web programming
■ GSM-SMS
■ e-mail
■ USB Device
■ RS-232
■ J1939-CANBUS

■ Technical information and values are according to ISO8528, ISO3046,NEMAMG-1.22, IEC 600341, BS4999-5000, VDE0530 standards.
■ Producing with ISO9001, ISO14001, OHSAS18001, TSE, CEstandards.
■ All information given in this leaflet is intended for general purposes only.
■ Due to a policy continuous improvement Teksan reserves the right to amend details and specifications without notice and all information given is subject to the Teksan's
current condition of sales.
TBA: To Be Asked TBD: To Be Determined NA: Not Avaliable N/A: Not Applicable TTDTJ330DW5L20200726EN

+45 64 41 59 02 [email protected] www.generator.dk

You might also like