0% found this document useful (0 votes)
28 views48 pages

PRO2-PRO1000 Intelli-Fit v2 ENG

The document is an owner's operation manual for the SCIFIT PRO2 Total Body Exerciser and PRO1000 Upper Body Exerciser, detailing safety information, specifications, setup, assembly, and operational instructions. It emphasizes the importance of following safety guidelines and consulting a physician before use, especially for individuals with health concerns. The manual also provides maintenance tips and warranty information, ensuring users can effectively and safely utilize the exercise machines.

Uploaded by

brian.w.bohman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views48 pages

PRO2-PRO1000 Intelli-Fit v2 ENG

The document is an owner's operation manual for the SCIFIT PRO2 Total Body Exerciser and PRO1000 Upper Body Exerciser, detailing safety information, specifications, setup, assembly, and operational instructions. It emphasizes the importance of following safety guidelines and consulting a physician before use, especially for individuals with health concerns. The manual also provides maintenance tips and warranty information, ensuring users can effectively and safely utilize the exercise machines.

Uploaded by

brian.w.bohman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 48

Touchscreen

Owner’s Operation Manual

PRO2® PRO1000

PRO2® Total Body Exerciser


&
PRO1000 Upper Body Exerciser

Before Using this product, read this manual and


follow all safety rules and operating instructions.
table of contents

safety information 1

introduction 2

SPECIFICATIONS 3-4

SET-UP & INSTALLATION 5

ASSEMBLY 6-16

PRODUCT OVERVIEW 17

KEYPAD FUNCTIONS 18

BIOMECHANICAL POSITIONING 19

ADJUSTMENTS 20-22

HEART RATE TRANSMITTER STRAP 23

PROGRAM INSTRUCTIONS 24- 33

Additional Key features 34

MAINTENANCE & SERVICE 35

WARRANTY 36-40

CERTIFICATION 41-42

WARRANTY CARD 43

Order on line 24/7 at www.SCIFIT.com

SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
safety information

The purpose of safety symbols is to attract your attention to possible dangers. The safety or attention symbols and their
explanations deserve your careful attention and understanding. The warnings do not, by themselves, eliminate any
danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.

Look for these symbols to point out safety precautions or important information.

CAUTION Warning

ATTENTION

Read all instructions before using your SCIFIT exercise machine. Save these instructions for future reference.

Close supervision is necessary when the exercise machine is being used by or near children or individuals with
disabilities. Keep children away from extended hand and foot supports.

Use the exercise machine only for its intended use as described in this manual. Do not use attachments not recommended
by the manufacturer.

Never drop or insert any object into any opening.

Do not use outdoors or in a harsh environment where water is present (i.e. pool or spa areas).

1
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
introduction
Thank you for your purchase of the SCIFIT PRO2 total Guidelines for Healthy Adults
body exerciser or PRO1000 upper body exerciser. We The American College of Sports Medicine (ACSM) and
have incorporated the finest technology and ergonomic the American Heart Association (AHA) are continuously
design into this machine to assist you in achieving your updating guidelines and recommendations for physical
fitness goals. However, for your safety, please adhere to the activity.
following recommendations before you begin to exercise.
The current basic recommendations from ACSM and AHA
The SCIFIT PRO2/PRO1000 are both designed for Class “S” is:
(Commercial) and Class “A” (High Accuracy). The PRO2
is also designed for Class “II a” (Medical Device Directive) Do moderately intense cardio 30 minutes a day, five days
applications. The intended uses are for Cardio & Pulmonary a week.
rehabilitation as well as sports medicine, physical therapy, OR
physical conditioning and strength training. The PRO2/ Do vigorously intense cardio 20 minutes a day, three days
PRO1000 are suitable for placement in fitness, medical a week.
rehab, sports performance and recreational facilities. Both AND
machines have 200 levels of console controlled resistance, Do eight to ten strength-training exercises, eight to twelve
which ensures that users of all fitness levels will be able to repetitions of each exercise twice a week.
get a challenging but not overwhelming workout.
Moderate-intensity physical activity means working hard
Consult Your Physician enough to raise your heart rate and break a sweat, yet
Consult your physician or medical specialist before still being able to carry on a conversation. It should be
participating in any exercise program, especially if you noted that to lose weight or maintain weight loss, 60 to
are pregnant, or if you are suffering from: heart disease, 90 minutes of physical activity may be necessary. The 30
respiratory disease, diabetes, hypertension, high blood minute recommendation is for the average healthy adult to
pressure, elevated cholesterol, arthritis, or any other maintain health and reduce the risk for chronic disease.
diseases and physical complaints.
To review the latest guidelines and recommendations,
Adult Usage visit the American College of Sports Medicine website:
SCIFIT equipment are designed and intended for adult usage www.acsm.org
and children of appropriate ages while being supervised.
Young children should be kept a safe distance away from
equipment. Warning
Stop exercising immediately if you feel nausea,
Cool Down dizziness, sharp pain, or any other physical discomfort.
To prevent muscle injuries and soreness, you should always Failure to stop exercising can result in injury or death to
cool down (at least 5 minutes) by doing a series of stretches yourself.
after each workout.
Train Intelligently
To ensure a future of good health, you should always eat
well balanced meals, drink plenty of fluid/water during a
caution workout, and stay fit by exercising intelligently. Always
follow training guidelines that are specific for your own
Always stretch after a workout session to reduce the risk physical condition.
of personal injury. Failure to stretch properly may result
in injury to yourself.
Warning
Injuries to health may result from incorrect or excessive
training. Failure to stop exercising can result in injury or
death to yourself.
2
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
specificationS
Weight PRO2 - 223 lbs (101 kg)
Max User Weight Swivel - 450 lbs (204 kg) Fixed - 500 lbs (227 kg) Bariatric - 600 lbs (272 kg)
Power Self generating w/auto recharge battery back-up.
Standard Low Voltage AC adapter.
Resistance System Electromagnetic Self Generating Bi-directional Resistance
Work Load Manual, Fit Quik, Constant Workout, ISO-Strength, 7 Pre-programmed Hills profiles, Heart
Rate, Power Fit, Heart Fit, Stress Test and Random
Accuracy Class Class A
Warranty Within U.S. & Canada 3 years parts, 1 year labor
Outside U.S. 3 years parts, no labor

61”
1524 mm

30”
762 mm

61.5”
1562 mm

3
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
specificationS
Weight PRO1000 - 220 lbs (100 kg)
Max User Weight Swivel - 450 lbs (204 kg) Fixed - 500 lbs (227 kg) Bariatric - 600 lbs (272 kg)
Power Self generating w/auto recharge battery back-up.
Standard Low Voltage AC adapter.
Resistance System Electromagnetic Self Generating Bi-directional Resistance
Work Load Manual, Fit Quik, Constant Workout, ISO-Strength, 7 Pre-programmed Hills profiles,
Heart Rate, Power Fit, Heart Fit, Stress Test and Random
Accuracy Class Class A
Warranty Within U.S. & Canada 3 years parts, 1 year labor
Outside U.S. 3 years parts, no labor

61”
1524 mm

30”
762 mm

61.5”
1562 mm

4
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
set-up & installation
Placement of Cardiovascular Machine 40” (1 M)
To aid in the placement of the machine, two wheels are Safety Space
located at the front of the unit. Movement of machine
should be done with two people. Carefully lift the rear of
unit until wheels are engaged with the floor, then position
the unit in the desired location.

Position the unit in a location that has a stable and level


sub-floor. Equipment should be positioned in a location that
is not in direct sunlight, in areas of extreme temperature Endcap Endcap
and humidity, or where the equipment may be splashed
with water or fluids. This machine is intended for indoor
use only.

Equipment should be positioned with a safety perimeter of


40” or 1 meter around unit.

Warning
Failure to place the equipment on a stable and level 40” (1 M) 40” (1M)
sub-floor with a safety perimeter can result in injury to Safety Space Safety Space
yourself and others.

Level Cardiovascular Machine


If the sub-floor is unlevel, the unit is equipped with leveling
end caps. The endcaps are designed with the recess of end
cap off centered. This allows you to rotate the endcaps to
a position that will level the machine. After adjustment,
check and make sure the end caps are fully seated against
base frame tubes.

Offset Endcap

40” / 1 Meter
Safety Space

Proper Supervision
Close supervision is required when the exercise machine
is being used by or near individuals with disabilities. Keep
unsupervised children outside the safety perimeter.

Cleaning
Never clean the machine with organic solvents, alcohol or
bleach based cleaners. To promote a healthy environment,
wipe any sweat off of unit with a commercially manufactured
wipe designed for the fitness industry, or a damp cloth.

5
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Mounting The Monocoque Frame To The Base Frame
(Reference diagram below)

1. With the aid of a second person, lift and set the main
CAUTION frame onto the base frame, aligning the threaded holes
Monocoque Frame is top heavy. Two people are required to with the mounting holes located at the front of the frame.
position frame in place. Failure to support frame properly
may result in injury to yourself and others. 2. Starting on the right side, insert a long needle point
center punch (A) through one of the front mounting holes
of the base frame to hold the main frame in place.
Required Tools:
Torque wrench with range above 576 in/lbs (65 N/m) 3. Slide (item #2) 3/8” split washer (Qty.1), then (item #3)
Long Needle Point Center Punch 3/8” flat washer (Qty.1) onto two of (item #1) 3/8” bolts.
5/16” (8mm) Hex Bit
4. Push up on monocoque frame to align the holes, then
loosely thread the bolts into the two open mounting holes.
Required Parts:
(Qty. 6) Item #1: #93305 - Bolt,3/8” x 1”, Socket Cap 5. Repeat step 3 for the last bolt, then return to center
(Qty. 6) Item #2: #33893 - Washer, Split, 3/8” punch (A) and pull it out to loosely thread in the last
(Qty. 6) Item #3: #1133815 - Washer, Flat, 3/8” remaining bolt.
6. Repeat steps 2 thru 5 for the left side.

7. Use the torque wrench to tighten all bolts to 576 in/lbs


(65 n/m).

2 A

6
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
SWIVEL SEAT ASSEMBLY

Step 1:
Pull upward on the yellow T-handle of the seat adjustment lever, then lift and slide the seat post onto the frame track making
sure the roller guide rail is between the top and bottom wheels of the base.

Roller guide

Step 2:
Attach the handlebar plate to the seat post with (Qty. 4) of items #1, #2, #3 and #4 as shown on the drawing below.

#1

Tools Required:
3/16” (5mm) Hex Bit
#2 1/2” (13mm) Wrench or socket
#3
#4
Item #1 (#94256)
5/16-18 x 1 Socket Flat Head Screw

Item #2 (#33080)
5/16 Flat Washer

Item #3 (#1133892)
5/16 Split Washer

Item #4 (#1136104)
5/16 Nut Hex

7
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
SWIVEL SEAT ASSEMBLY CONT’D

Step 3: (Bucket Seat Assembly )


a. Align the front holes of the bucket seat with the 3rd set of holes from the front of the handlebar plate,
(see diagram), then loosely screw in (Qty. 1) of item #1 into one of the front holes of the seat.
b. Align the other three holes and insert the other three screws loosely.
c. Tighten all four screws to secure the bucket seat.

Front holes of the bucket seat


Tools Required:
1/2” (13mm) Wrench or socket

Item #1(#19919)
5/16-18 x 1.25 Serrated Screw

#1
Rear holes of the bucket seat

Step 3a: (2-Piece Seat Assembly)


a. Align the front two holes of the seat mount plate with the 1st set of holes of the handlebar plate (see diagram), then
insert (Qty. 1) of item #1 into one of the front holes to hold the seat mount plate in place.
b. Align the front hole of the bottom seat pad with the inserted screw and loosely screw it into the seat pad.
c. Align the other front hole of the seat pad and loosely screw in (Qty. 1) of item #1 screw.
d. Slide (Qty. 1) item #3, then (Qty. 2) item #4 onto (Qty. 1) item #2, then loosely screw into the rear holes of the seat pad.
e. Tighten all four screws to secure the bottom seat pad and plate mount
Tools Required: Item #1 (#19919) Item #3 (#1133892)
1/2” (13mm) Wrench or socket 5/16-18 x 1.25 Serrated Screw 5/16 Split Washer

Item #2 (#110120325) Item #4 (9900264)


5/16-18 x 1 Hex Head Screw 5/16 Flat Washer

Front seat plate mounting holes

Rear seat plate mounting holes

8
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
FIXED SEAT ASSEMBLY

Step 1:
Pull upward on the yellow knob of the seat adjustment lever, then lift and slide the seat post onto the frame track making
sure the roller guide rail is between the top and bottom wheels of the base.

Roller guide

Step 2: (Bucket Seat Assembly)


a. Align the front two holes of the bucket seat and handlebar plate with the front set of holes on the fixed seat mount
(see diagram), then insert (Qty. 1) of item #1 into one of the seat holes and loosely tighten into place.
b. Align the second front hole of the seat and loosely tighten with (Qty. 1) item #1 screw.
d. Insert and loosely tighten the remaining two rear holes with (Qty. 2) item #1 screws.
e. Tighten all four screws to secure the seat to the fixed seat mount.

Align holes of seat with these


holes on the fixed seat mount

Tools Required:
1/2” (13mm) Wrench or socket

Item #1 (#19919) Front


5/16-18 x 1.25 Serrated Screw

Rear
(Item #1)

9
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly

FIXED SEAT ASSEMBLY CONT’D

Step 2a: (2-Piece Seat Assembly)


a. Align the front two holes of the seat mount plate with the 1st set of holes of the fixed seat mount. (see diagram), then insert
(Qty. 1) of item #1 into one of the front holes to hold the seat mount plate in place.
b. Align the front hole of the bottom seat pad with the inserted screw and loosely screw it into the seat pad.
c. Align the other front hole of the seat pad and loosely screw in (Qty. 1) of item #1 screw.
d. Align, then loosely screw in (Qty. 2) of item #1 into the two remaining rear holes.
e. Tighten all four screws to secure the bottom seat pad and plate mount.

Tools Required:
1/2” (13mm) Wrench or socket

Item #1 (#19919)
5/16-18 x 1.25 Serrated Screw

(Item #1)

Align bottom seat pad holes with


these four hole locations

10
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Verify Upper Cranks Are Secure
During shipment it is possible that the two set screws securing the crank hub to the shaft may become slightly loose.
It is strongly recommended that these set screws be checked before attaching the crank handles.
The following steps will explain this procedure.

Tools Required
• 5/16” (8mm) Hex bit
• Torque wrench set for 480 in/lbs (54 n/m).

Step 1:
Starting on the left side, use a 5/16 hex bit to remove the 1st set
screw #P3110 (5/8-18 x .5 Socket) and place to the side (Fig. 1).

Fig. 1

Step 2:
Using a 5/16 hex bit and torque wrench insert the bit into the crank
hub to reach the 2nd set screw #P3111 (5/8-18 x .75 Socket) and
TIGHTEN to 480 in/lb (54 n/m) (Fig. 2).

Note: The wrench will click when it has reached the 480 in/lb
(54 n/m) setting.

Fig. 2

Step 3:
Again using a 5/16 hex bit and torque wrench, reinsert the
set screw removed in step 1 into the crank hub hole and
TIGHTEN to 480 in/lb (54 n/m) (Fig. 3).

Step 4:
Fig. 3
Repeat steps 1 thru 3 for the right side.

11
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Verify Upper cranks Are Secure (Cont’d)

Step 5:
Starting on the right side, lift up on the yellow spring flange
adjustment knob on the hub and slide the crank into the hub, then
release the knob at the selected position (Fig. 4).

Fig. 4

Step 6:
Use a 5/32” (4mm) hex bit to secure the crank with a
1/4” flat washer (#10537-08370) and 1/4-20 x .5 socket cap
screw (#94049) on the end of each rod (Fig. 5).

Fig. 5
Step 7:
Repeat steps 5 & 6 for the left side

12
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Verify Lower Adjustable Cranks Are Secure (PRO2 Only)
During shipment it is possible that the two set screws securing the crank hub to the shaft may become slightly loose.
It is strongly recommended that these set screws be checked before attaching the crank handles.
The following steps will explain this procedure.

Tools Required:
• 5/16” (8mm) Hex bit
• Torque wrench set for 480 in/lbs (54 n/m)

Adjustable Lower Cranks (PRO2 Only)

Step 1:
Starting on the left side, use a 5/16 Hex bit to remove the 1st set
screw #P3110 (5/8-18 x .5 Socket) and place to the side (Fig. 1).

Fig. 1

Step 2:
Using a 5/16 hex bit and torque wrench insert the bit into the crank
hub hole to reach the 2nd set screw #P3111 (5/8-18 x .75 Socket)
and TIGHTEN to 480 in/lb (54 n/m) (Fig. 2).

Note: The wrench will click when it has reached the 480 in/lb
(54 n/m) setting.

Fig. 2

Step 3:
Again using a 5/16 hex bit and torque wrench, reinsert the
set screw removed in step 1 into the crank hub hole and
TIGHTEN to 480 in/lb (54 n/m) (Fig. 3).

Step 4: Fig. 3
Repeat steps 1 thru 3 for the right side.

13
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Verify Lower Adjustable Cranks Are Secure (Cont’d)

Step 5:
Starting on the right side, lift up on the yellow flange spring pin
knob of the hub and slide the crank into the hub, then release the
knob at the selected position (Fig. 4).

Fig. 4

Step 6:
Use a 5/32” (4mm) hex bit to secure the crank with a
1/4” flat washer (#10537-08370) and 1/4-20 x .5 socket cap
screw (#94049) on the end of each rod (Fig. 5).

Fig. 5
Step 7:
Repeat steps 5 & 6 for the left side

14
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Verify LWR Fixed Cranks Are Secure (PRO2 ONLY)
3/4” between the frame
Your machine may have the lower fixed crank hub option, these
(inside the cover) and the
hubs are usually removed for shipment purposes. If this is the inside edge of the hub.
case, attaching them is very simple. The following will explain
the steps necessary to attach the hubs.

Tools Required:
• 5/16” (8mm) Hex bit
• Torque wrench set for 480 in/lbs (54 n/m)
Fig. 1
Step 1:
Starting on the right side, slide the hub onto the lower shaft of the
machine, allowing 3/4” between the frame and the end of hub.
Align the set screw hole over the flat surface area of the shaft
(Fig. 1).

Step 2:
Place the set screw #P3111 (5/8 X .75 Socket) in the hub hole,
then using a 5/16 hex bit and torque wrench set at 480 in/lbs
(54 n/m), secure the set screw to the shaft (Fig. 2).

Note: The wrench will click when it has reached the 480 in/lb Fig. 2
(54 n/m) setting.

Step 3:
Place the set screw #P3110 (5/16-18 x .5) in the same hole as
the previous set screw from step 2, then use a 5/16 hex bit and
torque wrench to secure it on top of #P3111 at 480 in/lbs (54 n/m)
(Fig. 3).

Step 4:
Slide the lower foot crank into the hub so the desired hole placement
on the rod aligns with the hole on the hub, then insert the set screw
#P4394 (5/8-11 x .5 Socket) and use a 5/16 hex bit and torque wrench Fig. 3
to tighten the set screw to 480 in/lbs (54 n/m) (Fig. 4).

Note: The wrench will click when it has reached the 480 in/lb
(54 n/m) setting.

Fig. 4

15
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
assembly
Verify LWR Fixed Cranks Are Secure (CONT’D)

Step 5:
Take the second #P4394 (5/8-11 x .5) set screw and place it in the
hub hole on the underside, then secure the set screw with a 5/16
hex bit and torque wrench set at 480 in/lbs (54 n/m) (Fig. 5).

Step 6: Fig. 5
Use a 5/32” (4mm) hex bit to secure the crank with a 1/4”
flat washer (#10537-08370) and 1/4-20 x .5 socket cap screw
(#94049) on each rod (Fig. 6).

Step 7:
Repeat steps 1 thru 6 for the left side.
Fig. 6

16
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
product overview
PRO2 PRO1000
Console: Intelli-Fit Touchscreen Console Console: Intelli-Fit Touchscreen Console

Upper Cranks: Adjustable or Fixed Upper Cranks: Adjustable or Fixed


Lower Cranks: Adjustable or Fixed Molded Foot Rests: Yes, Removable
Seat Assemblies: Adjustable, Fixed or Bariatric Seat Assemblies: Adjustable, Fixed or Bariatric
Foot Pedal Assist: Adjustable Seat Assembly Only Foot Pedal Assist: Adjustable Seat Assembly Only
Front End Transport Wheels: Yes Front End Transport Wheels: Yes
Leveling Endcaps: Yes Leveling Endcaps: Yes
Wheelchair Tie Down Anchors: Yes Wheelchair Tie Down Anchors: Yes

17
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
KEYPAD FUNCTIONS

ATTENTION
The tactile keys on the membrane switch are fully functional and may still be used for
Data Entry, Workout selection, etc., if so chosen.

Pause Enter Quick


Clear
Start WORKOUT
SELECTION
WARNING! Heart rate monitoring systems may be inaccurate.
Over exercise may result in serious injury.
The operator can
If you feel faint or pain stop exercising immediately choose up to twelve
different workouts.
PAUSE/CLEAR
This key pauses the workout at anytime.
Three choices then become available:
1. Continue the workout QUICK START UP/DOWN ARROWS
2. Change data entry information Begins a pre-programmed These keys increase or
3. Stop the workout workout session. decrease values of workout
parameters.

SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT

ENTER
This key confirms the
operator’s category value
selection in the data entry
screen.

18
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
BIOMECHANICAL POSITIONING
Swivel, Fixed Seat and Wheelchair Use
Adjust the seat or wheelchair forward or backward to a
comfortable location for the upper body movement. A slight
torso rotation is desired on extension. Avoid locking arms at
extension by adjusting the seat position or arm crank radius.
Adjust the height of the cranks to a comfortable position
that encourages proper posture or at the desired angle
for specific training or rehabilitation movements. Such
movements and adjustments should be under the guidance
and supervision of a fitness or medical professional. If your
PRO2 or PRO1000 features a seat with height adjustment,
you may adjust either seat height to obtain the desired axis
of rotation and body position.

caution
Always follow medical professionals guidelines to
reduce the risk of personal injury. Failure to follow their
directions may result in injury to yourself.

Console Adjustment
The console should be positioned so it is eye level or in direct
line of sight of the user. The console can be repositioned
by pushing backwards or pulling forward to the desired
position (Fig. 1).

Fig. 1

19
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ADJUSTMENTS
Crank Length Adjustment
Adjust the foot and crank arm radius to a desired length.
The longer the crank arm length the larger the circle the
user will experience when exercising. Generally a larger
circle will result in broader muscle recruitment and greater
torso rotation. 8” Radius

Comfort is a key issue and these guidelines may be helpful.

Users Height:
5’ 6” and under = shortest crank settings
2nd Hole Position Fig. 4
5’ 7” to 5’10” = middle crank settings
5’ 11” and taller = longest crank setting

Important Note: When using this product for medical or


rehabilitation purpose, the crank radius, seat height and
distance should be set by the attending therapist or medical
professional based on the specific needs of the user. 7” Radius
To adjust the crank arm position, pull outward on the
yellow flanged spring loaded knob locking pin and align
with the predrilled holes on the crank rod to a new position
(Fig. 2 thru 6).
3rd Hole Position Fig. 5

6” Radius

Fig. 2 4th Hole Position Fig. 6

Reversing The Crank For a Rowing Motion


The upper crank arms can be easily adjusted to work in
unison (rowing motion).
1. Remove the screws and washers from both ends of the
right side crank.
2. Pull the yellow flange adjustment knob outward and
9” Radius remove the right crank.
3. Turn the crank upside down and reinsert it into the hub,
then reinstall the screws and washers.
It is important to know that the rowing function
can not work in conjunction with the lower body
1st Hole Position Fig. 3
movement of the PRO2.

20
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ADJUSTMENTS
Foot Crank Adjustment
Foot crank pedals can be adjusted to accommodate user height, achieve proper bio-mechanical positioning and work
different muscle groups.

To adjust foot crank position, pull outward on the yellow flange adjustment knob and move the foot crank to the desired
hole position (Fig. 1 thru 4).

5.60” Radius

Fig. 1
2nd Hole Position Fig. 3

6.85” Radius 4.35” Radius

1st Hole Position Fig. 2 3rd Hole Position Fig. 4

21
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ADJUSTMENTS
Swivel Seat Assembly Adjustments Vertical Adjustment - Pull up on the yellow paddle
shaped handle to raise or lower the seat.
Horizontal Adjustment - The seat can be adjusted in 1” NOTE: No weight should be on the seat when raising.
(25.4mm) increments and is held in place with a spring
loaded adjustment pin. This is done by pulling upward on
the T-handle yellow knob or stepping on the foot assist
pedal, then slide the seat assembly forward or back to the
desired position.

PRO2 - Adjust the seat assembly so both the


arms and legs have a slight bend at full extension.
Pull up for vertical
PRO1000 - Adjust the seat assembly so the arms have a adjustment
slight bend at full extension. The feet can be located in the
most comfortable area on the flat surface of the foot rest.

Yellow Swivel Adjustment - Push down on the yellow paddle


T-handle shaped handle to rotate the seat. The seat will lock into
place at each 90 degree position.

Foot Assist

Push down to rotate


seat

22
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
HEART RATE TRANSMITTER STRAP
Heart Rate Transmitter Strap Calculating Target Heart Rate Zone
The optional wireless heart rate transmitter accessory is a Your approximate Maximum Heart Rate (MHR) is equal
useful device if you desire continuous feedback on your to 220 minus your age. The upper limit of your target zone
current heart rate during a workout. In addition the PRO1 is equal to 0.85 times your MHR. The lower limit of your
includes a heart rate control program which requires use of target zone is equal to 0.60 times your MHR.
the strap.
For Example:
The heart rate control programs enables the user to setup Your age is 40:
a target heart rate. Through real-time monitoring of the 220 - 40 = 180
user’s heart rate, the console maintains the user’s heart rate 180 x .85 = 153 (max MHR)
at or below this established target rate by decreasing the 180 x .60 = 108 (min MHR)
workload if the user’s heart rate exceeds the target.
These values are based upon averages, always consult your
Activating & Deactivating Transmitter physician to establish the proper heart rate zone for your
Heart rate transmitter straps come in a variety of styles and individual health condition.
manufacturers. To properly activate, secure strap to the
chest and to deactivate follow the instructions that come
with the transmitter strap. Note: The heart rate program will maintain your HR
within a 10 BPM range of your set target. This variable
may depend upon maintaining a constant RPM
(Cadence).
caution
Always follow manufacturers instructions for proper care
and use. Failure to follow manufacturers instructions
may result in injury to yourself.

warning
Heart Rate monitoring systems may be inaccurate.
If you feel faint, stop exercising immediately. Over
exercising may result in serious injury or death.

23
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Programs
SCIFIT products have 200 levels of computer controlled When a workout program has been selected, the console
resistance, which ensures that users of all fitness levels will then advance to the “Data Entry” mode where
will be able to get a challenging but not overwhelming additional information is entered prior to the workout
workout. Because the resistance is adjustable in .1 commencing.
increments, it is easy for the user to track progress. SCIFIT
products feature one of the highest resistance capabilities The user will have two options of entering data as each
available on any cardio equipment. category is displayed on the screen.
The PRO2/PRO1000 are self-generated and has an A. Using the numerical touchscreen keypad (No. #1).
extremely low starting resistance. One pedal movement Note:
activates the console and the screen will remain lit at the The “Delete” key will remove the last digit
most minimal levels of movement. entered from the keypad (right to left).
The “Back” key will return you to the previous screen
The PRO2/PRO1000 have a battery back up which will
keep the screen lit for a short period after the workout B. Using the “+” or “-” arrow keys (No. #2).
is completed or if the user stops. This varies between 0 C. When the correct information has been entered,
seconds and 3 minutes and can change with the amount of touching the “Accept” button will save the data and
use each product gets. advance to the next category or begin the workout if it is
the last category (No. #3).
If you prefer the console to remain lit at all times, an optional
AC adapter can be plugged into the machine to accomplish
this. This is common in medical settings and with Fit-Key
Programs. (#2) (#1)
Touchscreen
Touchscreen allows the user to select any program or
key feature on the console with just a finger tip touch of
the screen. The PRO2/PRO1000 offer workout program
options that can be selected from the touchscreen display (#2)
(Menu screen example shown below). Six programs are
shown on the screen at one time, additional programs can (#3)
also be viewed by touching the “More” key on the screen.

24
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Programs Using the data entry options described on page 24:
The PRO2/PRO1000 machines offer twelve workout
Enter the workout duration:
programs (Not including Quick Start). The following is a
summary.

Quick Start Time


Allows the user to get on the machine and go. Touching 15:00
the “Quick Start” key at the main screen begins a workout
with no set time limit. The intensity level can be changed by
pressing the “Menu” key on the screen to view additional
key features.

Touch the key. Touch the key.

Select the level intensity:


Changing The Intensity Level:

Touch the key.


Level

Additional key features will appear at the bottom of the 1.0


screen.

Touching the “Increase or Decrease” keys will change the Touch the key.
workout intensity level.

Enter the user weight:


Manual Workout
Allows the user to set the intensity at any level. This level
will not change unless the user manually increases or
decreases the intensity. Weight
150

Touch the key.

Touch the key

and begin the workout.

25
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Constant Work Enter the user weight:
Workout resistance is automatically adjusted to compensate
for any change in speed (RPM), thus the amount of work
will remain constant at any given (Watts) setting.

Weight
150
Touch the key.

Enter the workout duration:

Touch the key.

Time and begin the workout.


15:00
ISO-Strength Program
ISO-Strength is a isokenitic program, meaning that
the unit will resist your movements in order to force
you to stay at a set speed. This type of strength
workout will not cause excessive soreness. The
console will adjust resistance to keep the user at the
Touch the key. target RPM speed.

Touch the key.


Enter the target watts:

Enter the workout duration:

Target
20
Time
5:00

Touch the key.

Touch the key.

26
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
ISO-Strength Cont’d

Enter the target RPM: Select the course profile:

Target
60 Course

Touch the key. Touch the key.

Enter user weight: Enter the workout duration:

Weight Time
150 15:00

Touch the key. Touch the key.

and begin the workout.


Select the level intensity:

Hills Program

Allows the user to select from seven different Hill profiles Level
set at various pre-programmed intensities. 1.0
The following profiles are available: Course, Sprints,
Twin Peaks, Peak, Progressive, Multi-Peaks and Ramp.

Touch the key.

Touch the key.

27
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Enter the user weight: If the signal continues to be undetected the program
will exit and return to the main screen.

Weight
150 Touch the key.

Enter the workout duration:

Touch the key.

and begin the workout.


Time
15:00
Heart Rate Program
A heart rate transmitter chest strap is required for this program.
Refer to page 23 for a complete instruction on using the strap
and to understand how to calculate your target heart rate.
• Place the transmitter strap on your chest

Touch the key.

Enter the target heart rate:

ATTENTION Target
120
If you are not wearing a transmitter belt or the belt is not
sending a signal correctly, after a short period of time
the following message will appear.

Touch the key.

28
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Heart Rate Cont’d

Enter the user weight: More


Pressing this key will change the screen to show an
additional six more pre-programmed workouts.

Weight
150

Touch the key.

Touch the key.

and begin the workout. Random Program


This program randomly displays different workout profiles
Fit Quik R

each with its own level of difficulty. The user only has to
Allows the user to select a two stage program of choose the type of profile, length of workout time and the
cardiovascular work with ISO-strength (Isokinetic). level difficulty.
Work loads and time durations are preset within the Set-Up
mode. Note: The highest column of the profile represents the
The following category is only seen when Manual, Hills or highest workout level you selected. Columns below it are
Constant Work is selected in the “Set-up mode”. percentages of the level selected.

Touch the key. Touch the key.

Enter the user weight: Select the course profile:

Weight
150 Random

Touch the key. Touch the key.

and begin the workout.

29
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Random Cont’d

Enter the workout duration: Stress Test


A designed stress test to be used as a training program
or use with other diagnostic devices (if applicable).
The user sets a target wattage with timed intervals and
preset wattage increments.
Time
15:00

Touch the key.

Touch the key.

Select the level intensity: Enter the wattage target for the initial step:

Level First Target


1.0 50

Touch the key. Touch the key.

Enter the user weight: Enter the wattage increments of change for the next
steps:

Weight
150 Increments
5

Touch the key.


Touch the key.
and begin the workout.

30
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Stress Test Cont’d Power Fit Test
This test is based on a pre-programmed workout
Enter the time of intervals at each step : designed to evaluate your “Power Drop %”, which
gives a fitness indication of power and strength using
wattage as the main measurement.

Interval
5:00
Touch the key.

and begin the workout.

Touch the key. Power Fit Training


Specifically designed preset wattage training programs
based off the user’s “Power Fit” test evaluation. Three
Enter the user weight:
programs and four levels (Beginner, Intermediate,
Advanced and Sport performance) are available.

Weight
150
Touch the key.

Select 1 of 3 programs (3 being the most difficult):

Touch the key.

and begin the workout.


Program
1

Touch the key.

31
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Power Fit Training Cont’d

Enter 1 of 4 the intensity levels


(4 being the most difficult): ATTENTION
If you are not wearing a transmitter belt or the belt is not
sending a signal correctly, after a short period of time
the following message will appear.

Level
Beginner

Enter 1 of 4 the intensity levels


Touch the key. (4 being the most difficult):

Enter the user weight:


Level
Beginner
Weight
150

Touch the key.

Enter the user weight:


Touch the key.

and begin the workout.


Weight
Heart Fit Test 150
This program is based on a pre-programmed workout
designed to evaluate your heart rate recovery. The user
can select from 1 to 4 levels (Beginner, Intermediate,
Advanced and Sports Performance).

Touch the key. Touch the key.

and begin the workout.

32
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
PROGRAM INSTRUCTIONS
Heart Fit Training. Enter 1 of 4 the intensity levels
Designed training programs based on the user’s evaluated (4 being the most difficult):
Heart Fit test. A training schedule with retesting is
recommended. The user has three programs and four
levels (Beginner, Intermediate, Advanced and Sports
performance) to choose from.
Level
Beginner
Touch the key.

Touch the key.


ATTENTION
If you are not wearing a transmitter belt or the belt is not
sending a signal correctly, after a short period of time
the following message will appear. Enter the user weight:

Weight
150

Select 1 of 3 programs
(3 being the most difficult):

Touch the key.

and begin the workout.


Program
1

Touch the key.

33
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
ADDITIONAL KEY FEATURES
The SCIFIT touchscreen console also includes extra This activates two 3-speed cooling fans
user friendly key features that may be accessed during a (Low, Medium, High) at anytime during the
workout. workout. Each touch of the key will change
the fan airflow speed.
Once a workout commences, the word “Menu” will appear
in the lower right corner of the screen. This feature increases resistance for a short
duration of time during the workout when
Just a touch of the “Menu” icon activates a pop-up menu activated. Touching this key will activate the
that appears at the bottom of the screen for additional feature and a short count down will be seen
selections. on the screen to prepare the user. The duration
length of the “Power Burst” can be increased
or decreased in the “Set-up” mode.
Touch the key.
Only seen when the “Random” program is
selected. It allows the user to change the
Pop-up menu with additional key features appear. current workout profile at the bottom of the
screen to a different one by touching the
“Change Profile” key anytime during the
workout.

Key Descriptions
Allows the user to change the viewing format
of the workout profile and data displayed on
the screen during the workout.

Allows the user to change the


intensity of the workout.

Pauses the workout program at anytime. The


screen then changes providing the user with
three options as shown below.

Change
Returns to the data entry screen where the information
previously entered can be changed.
Continue
Restarts the workout program at the point where the user
had paused it.
Stop
Exits the workout and returns to the main screen.

34
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
MAINTENANCE & SERVICE
Maintenance UNITED STATES CUSTOMER SERVICE
The PRO2 and PRO1000 are virtually maintenance free. For assistance in the service of SCIFIT products;
After training, always wipe down your SCIFIT exercise
product. Perspiration that continuously settles on the frame, phone : +1 (918) 359-2000
upholstery, casings, and control console may eventually fax : +1 (918) 359-2045
cause rust or damage. Damage resulting from lack of e-mail: [email protected]
maintenance is not covered under warranty.
The Product Support department is available by means
If defective components are identified and require of email. A voice mail service is available 24 hours a day
replacement, the equipment should be put out of service for recording messages to request technical support and to
until repaired. order replacement parts. Our mailing address is:

SCIFIT Systems Inc.


5151 S. 110th E. Ave.
caution Tulsa, OK 74146
Always follow manufacturers instructions for proper care USA
and use. Failure to follow manufacturers instructions
may result in injury to yourself.
UK & EUROPEAN CUSTOMER SERVICE
PRO2/PRO1000 Maintenance Schedule phone : +44 1344 300022
fax: +44 1344 868838
Any mechanical or electrical work conducted within e-mail: [email protected]
the main body of a medical CE class IIa unit MUST BE
RECALIBRATED. The generic maintenance schedule SCIFIT LTD (UK)
below should be applied to medical CE and non-medical Lexham House
CE products Forest Road
Binfield
COMPONENT USE WHEN BY WHOM Berkshire, RG42 4HP
Covers, Seat, Handlebars Damp Cloth Daily Club Maintenance UK
and Console

LCD Screen LCD TV Screen Weekly Club Maintenance Company Number: 5970624 (UK)
soft cleaning cloth
Chains Lightly Applied Every Club Maintenance *COUNTRIES OUTSIDE OF UK & EUROPE
Chain Lubricant 6 Months
PLEASE USE USA CONTACT NUMBERS*
Nuts and Bolts Tighten When Bimonthly Club Maintenance
Necessary
Base Roller Guide Track Damp Cloth Monthly Club Maintenance
Every
Battery Voltmeter 6 Months Club Maintenance

CAUTION
Contact your local waste management agency for
specific requirements concerning recycling and disposal
locations of batteries.

Order online 24/ 7 at www.SCIFIT.com

35
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
WARRANTY

It is very important that your SCIFIT machine is registered. This can be


done online at http:/www.SCIFIT.com/warrantyregistration.shtml/ or fill out and
mail the registration form on the back of this manual.

SCIFIT Statement of Warranty

SCIFIT warranties new products against defective workmanship and/or materials under normal and proper use
subject to the following limitations:

(a) SCIFIT’s obligation to the original purchaser shall apply within the United States and Canada
to both parts and the cost of labor required to replace or repair a defective product, at SCIFIT’s
option, for a period of one (1) year from user/dealer purchase date as documented by *warranty
card and if warranty card has not been returned by user/dealer, then date of shipment from the
factory. Thereafter, for a period of two (2) years, such obligation shall extend only to the supply of
replacement parts with any labor costs associated with such replacement or repair to be at buyer’s
expense. Refer to clause (e) for components outside this policy clause.

Outside the United States and Canada SCIFIT will repair or replace defective product with no labor
included for a period of three (3) years from user purchase date as documented by *warranty
card and if warranty card has not been returned by user then date of shipment from factory. However
these warranty periods for sales outside the United States and Canada are subject to modification by
local SCIFIT sales dealers.

*Note: Original purchaser must register their purchased products either by warranty card return,
web site registration or fax to activate warranty period or shipment date is extant for start of warranty
period. A ninety (90) day period is to be given for warranty registration to allow stock rotation and
showroom stock thereafter registration will be shipment date for the start of the warranty period.

(b) SCIFIT’s obligation shall be limited to repairing or replacing defective parts. No allowance
shall be granted for repairs made by Buyer without SCIFIT’s prior written approval. The decision
to replace or repair shall be solely at SCIFIT’s discretion. SCIFIT reserves the right to require return
of warranty parts, or payment, in some cases. See “Return of Parts” below.

(c) SCIFIT’s warranty does not apply to parts requiring replacement or repair due to normal
and abnormal wear and tear, improper use, corrosion (perspiration), improper maintenance, improper
installation, improper rated, grounded or dedicated electrical circuits or improper storage,
nor it apply where all or part of the product has been altered from its original state by Buyer
or a third party.

(d) THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,


ARISING BY LAW OR OTHERWISE INCLUDING WARRANTY OR MERCHANTABILITY OF
FITNESS FOR PARTICULAR PURPOSE, AND IS IN LIEU OF ALL OTHER LIABILITIES
OF SCIFIT INCLUDING DIRECT, INDIRECT, SPECIAL AND CONSEQUENTIAL DAMAGES
OR PENALTIES EXPRESSED OR IMPLIED WHETHER ARISING OUT OF CONTRACT,
NEGLIGENCE OR OTHER SORT.

36
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
WARRANTY
SCIFIT STATEMENT OF WARRANTY

(e) The below listed items have the following warranty coverage unless
determined to be defective. These items include, but are not limited to:

Treadmill Warranty Period


AC5000/AC5000M
DC1000 (6hr. per day usage)
Treadmill belts 12 months
Treadmill decks 12 months
Treadmill structure & frame 5 years
Treadmill drive system inclusive of 5 years
motor & inverter
Treadmill handrails & handles 3 years
Treadmill heart rate grips 12 months
Treadmill water bottle holders 90 days
Treadmill trays 90 days

Rotary Products Warranty Period


Upholstery 12 months
Saddles/seats 12 months
Rotary pedals 12 months
Rubber grips 12 months
Heart rate grips 12 months
Rotary structure & Frame 5 years
Rubber foot pads (BioFlex) 12 months
Rotary water bottle holders 90 days
Rotary trays 90 days
Battery 1 year

Accessories Products Warranty Period


Pedal straps Normal wear & tear
Heart rate receiver/transmitter 90 days
Low support boots 12 months
High support boots 12 months
Assist gloves 90 days
USB keys and Lanyards 90 days

(f) Fires, floods, and acts of God, are not covered under this warranty.

37
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
WARRANTY

Freight and Shipping

All SCIFIT products have displayed on the outside packaging “STOP – UPON DELIVERY
INSPECT MERCHANDISE THOROUGHLY NOTING ANY DAMAGE ON RECEIVING
PAPERWORK PRIOR TO SIGNING”.

..............................................................................

Shipping and Installation

SCIFIT is not responsible for the repair or replacement of any unit or part damaged during transit
or installation. The customer is responsible for inspection of each unit and part for shipping
damage at the time of installation. If the customer signs an unqualified receipt for freight or
damage goods, the customer is solely responsible for the cost of the repair or replacement
for such freight damage.

..............................................................................

Software, Trademarks, Copyrights and Patents

If an order includes computer software, such software is transferred by SCIFIT to the customer
pursuant to a single user license, the royalty terms and conditions of that are set forth on or in the
package accompanying the software.

SCIFIT has trademarked several names to uniquely identify its business and products. These
names must not be used by other entities and remain the exclusive right of SCIFIT. SCIFIT’s
decals, user manuals, and service manuals are copyrighted and may not be copied without prior
written approval from SCIFIT.

SCIFIT owns patents on designs and features that are unique to its products. SCIFIT will defend
these patents against those who attempt to utilize these features and designs in other products.

38
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
WARRANTY

Maintenance

After using, always wipe down your SCIFIT exercise


product. Perspiration that continuously settles on
frame, upholstery, casings and control panels may
eventually cause rust or damage. Damage resulting
from lack of maintenance WILL NOT be covered under
warranty. To clean upholstery, use mild soap and warm
water, then dry with a clean towel. Refer to the machine
maintenance schedule.
..............................................................................

Product Support

Assistance for the service of SCIFIT products is available by

• Fax: +1 (918) 359-2045


• Phone: +1 (918) 359-2040
• Toll Free: +1 (800) 745-1373
• Email: [email protected]

The product support department is staffed from 7 AM to 5 PM US Central Time Monday through
Friday. A voicemail service is available 24 hours daily for recording messages to request technical
support and to order replacement parts. Our goal is to return every voicemail call within 30
minutes of when it is placed during our normal business hours. Some parts may be ordered
online using a credit card at: www.SCIFIT.com

Please have the following information prior to calling technical support:


• Model number of equipment
• Serial number of equipment
• Point of contact name and phone number
• Detailed description of symptoms encountered.
..............................................................................

Parts Shipment

During the first 30 days warranty parts will be shipped via overnight delivery. Determination
must be made before 2:00 PM US Central Time on any given weekday for next day delivery.
During the remainder of the first year warranty period, parts requirements will be filled via ground
shipment. The customer will have the option to request overnight or 2nd day parts shipping, but
will be charged the difference between the ground shipment cost and the overnight or 2nd day
cost.

39
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
WARRANTY

Return of Parts
SCIFIT is committed to continual improvement in the equipment we market. In order to meet
this commitment, the rapid return of defective parts is essential. The examination of the parts by
our engineering department leads to changes that insure the same problem does not re-occur.
Thank you in advance for your assistance!

When requested by SCIFIT, defective parts must be returned to the SCIFIT factory within 20 days
of receipt of replacement part. SCIFIT reserves the right to invoice buyer and collect for parts
where SCIFIT has requested the parts be returned and buyer has refused to do so.

Please follow these three easy steps for returning parts.


Step 1
Keep the box and packing material in which the new parts arrived.

Step 2
A prepaid return label will be in the parts box for only those parts that need to be returned. If no
prepaid return label is enclosed contact SCIFIT product support at

• Phone: +1 (918) 359 - 2040


• Toll Free: +1 (800) 745 -1373
• Email: [email protected]

When ALL of the parts are received and inspected at the factory, a credit will be issued for the
original parts invoiced. Attention service companies – Labor invoices will NOT be paid until the
defective parts are returned to the factory.

Step 3
Wrap the defective part, place it in the box and affix the return label for a safe return.
.......................................................................
Service Labor
Where applicable, the SCIFIT product support personnel will arrange a local field service
technician to provide field support. Every effort will be made to schedule service during 48
business hours (8 hours per business day) following notification of a problem or as soon as
repair parts are available to the field service technician. Where possible, parts will be supplied in
advance of the field service technicians so that the product is repaired with one call.
.......................................................................
Purchased Parts
All purchased parts will carry a 12 month warranty. Refer to purchased parts shipments and
installation for more information.
.
This Limited Commercial Warranty supersedes the Limited Commercial Warranty printed in the
“Owner’s Operation Manual” for all SCIFIT Systems, Inc. products.

If you have questions or require additional information, please contact SCIFIT Systems, Inc. at:

• Phone: +1 (918) 359 - 2040


• Toll Free: +1 (800) 745 - 1373
• Email: [email protected]

40
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
CERTIFICATIONS

DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY

Address: SCIFIT Ltd (UK) Address: SCIFIT Ltd (UK)


Lexham House, Forest Road Lexham House, Forest Road
Binfield, Berkshire, RG42 4HP Binfield, Berkshire, RG42 4HP
United Kingdom United Kingdom

EU Support: +44 1344 300022 EU Support: +44 1344 300022


Email: [email protected] Email: [email protected]
Web: www.scifit.uk.com Web: www.scifit.uk.com

Manufacturer: SCIFIT Ltd (UK) Manufacturer: SCIFIT Ltd (UK)

Product: PRO2 Arm and Leg cycle Product: PRO1000 Arm cycle
Class A (high accuracy class) per EN957-1:2005 Class A (high accuracy class) per EN957-1:2005
Class S (commercial use class) per EN957-1:2005 Class S (commercial use class) per EN957-1:2005

We, SCIFIT Systems, Inc., hereby declare that the product listed above is in We, SCIFIT Systems, Inc., hereby declare that the product listed above is in
conformity with the following standards and/or normative documents: conformity with the following standards and/or normative documents:

ISO 9001:2008 ISO 9001:2008


EN 957-1:2005 EN 957-1:2005
EN 957-5:2009 EN 957-5:2009
EN 60601-1-2:2006 EN 60601-1-2:2006
EN 60601-1: A1 1993. A2 1995 EN 60601-1: A1 1993. A2 1995

Steve Wright Steve Wright


European Business Development Director European Business Development Director
January 4, 2012 January 4, 2012

0434
DECLARATION OF CONFORMITY
Address: SCIFIT Ltd (UK)
Lexham House, Forest Road
Binfield, Berkshire, RG42 4HP
United Kingdom

EU Support: +44 1344 300022 If your PRO2 machine has CE on the label followed
Email: [email protected]
Web: www.scifit.uk.com by “0434”, it is a medical machine. The label will be
Manufacture: SCIFIT Ltd (UK)
located at the front of the machine next to the serial
Product: PRO2 – Total Body Exerciser
number.
Class IIa device per rule 10 of Annex IX of 93/42/EEC.
Class A (high accuracy class) per EN957-1:2005
Class S (commercial use class) per EN957-1:2005

We, SCIFIT Systems, Inc., hereby declare that the product listed above is in
conformity with the essential requirements of the EC Council Directive 93/42
EEC Medical Device Directive, as amended by 2007/47/EC and is in conformity
with the following standards and/or normative documents:

ISO 13485:2003
ISO 9001:2008
EN 957-1:2005
EN 957-5:2009
EN 60601-1-2:2006
EN 60601-1: A1 1993. A2 1995

Steve Wright
UK Managing Director
17 January, 2012

41
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
CERTIFICATIONS

 
 










 
 
 
 








 

 
   
  
  
  


  
  



  


 
  
 



 


 



42
SCIFIT • Scientific Solutions for Fitness • SCIFIT • Scientific Solutions for Fitness • SCIFIT
SCIFIT®
Warranty Card

Register online at http://www.SCIFIT.com/warrantyregistration.shtml or

SCIFIT
complete this form, fold it and return it to SCIFIT. We request you send this card
within 2 weeks after your equipment has been delivered to insure proper warranty
registration.

Company Name
Contact Name
Address
City/State/Zip

SCIFIT
Home Phone (____) Business Phone (_____)
Model Purchased
Date Received Serial Number
Entity Purchased From

43
City/State
Please rank the following reasons (1 through 6) for selecting SCIFIT with 1
being most important:

SCIFIT
____Features____Quality____Price____Dealer___User Friendly___Appearance
Please Check the appropriate box(s) on how you were introduced to SCIFIT:
Saw in ______________________ Magazine Introduced by SCIFIT Dealer
Saw at ____________________ Tradeshow Referred by SCIFIT User
Other
Comment

SCIFIT
Thank You For Choosing

P2278 Rev. B
www.SCIFIT.com
From
SCIFIT
5151 South 110th East Avenue
Tulsa, OK 74146
Important: Please keep this page for “Recalibration records”

Model Number:

Serial Number:

Date of Purchase:

Calibration Date
Medical Units:

Supplied By: SCIFIT Systems Inc.

User Manual: #A5602A (7/2013)

club or tech
DATE certification location certified service company initials

1st
Recalibration

2nd
Recalibration

3rd
Recalibration

4th
Recalibration

5th
Recalibration

Please make extra blank copies for future use


Order online 24/7 at www.SCIFIT.com

You might also like