Supporting Document - e Challis Seasonal Housing Drawings

The document outlines the specifications and schedule of items for the construction of seasonal bunkhouse housing at Salmon Challis and Sawtooth National Forest in 2016. It includes detailed descriptions of various bid options for modular bunkhouses, site furnishings, and utility installations, along with notes on existing structures and utility lines. The document serves as a comprehensive guide for contractors involved in the project, detailing requirements for construction and site preparation.

Uploaded by

CODERS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views43 pages

Supporting Document - e Challis Seasonal Housing Drawings

The document outlines the specifications and schedule of items for the construction of seasonal bunkhouse housing at Salmon Challis and Sawtooth National Forest in 2016. It includes detailed descriptions of various bid options for modular bunkhouses, site furnishings, and utility installations, along with notes on existing structures and utility lines. The document serves as a comprehensive guide for contractors involved in the project, detailing requirements for construction and site preparation.

Uploaded by

CODERS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 43

SUPPORTING DOCUMENT – E

AG-0261-S-16-0047

SEASONAL BUNKHOUSE HOUSING 2016


SALMON CHALLIS AND SAWTOOTH NF

CHALLIS SEASONAL HOUSING DRAWINGS

43 Pages
(including this header page)
SCHEDULE OF ITEMS
CHALLIS SEASONAL HOUSING
(Final - 3/1/2016 - RO Design Team)
ITEM METHOD
NUMBER DESCRIPTION OF MEAS UNIT QUANTITY PRICE TOTAL BID OPTION "A" - (MODULAR BUNKHOUSE #3)

BASE BID ITEMS (BUNKHOUSE & PARKING LOT) 000050-3 Accessible Bunkhouse Building #3 (1,560sf) (includes concrete Foundation) LSQ LS Lump Sum
Accessible Modular Bunkhouse Building #1 (1560sf) (includes concrete
000050-1 Foundation) LSQ LS Lump Sum 260500-3 Electrical Feeder Spur (bunkhouse #3) LSQ LS Lump Sum

000050-2 Modular Bunkhouse Building #2 (1560sf) (includes concrete Foundation) LSQ LS Lump Sum Total Option "A":

010250 Construction Staking LSQ LS Lump Sum

011900 Mobilization LSQ LS Lump Sum BID OPTION "B" - (MODULAR BUNKHOUSE #4)

024102 Removal of Structures and Obstructions LSQ LS Lump Sum 000050-4 Accessible Bunkhouse Building #4 (1,560sf) (Includes Concrete Foundation) LSQ LS Lump Sum

026460 Dumpster Pad (Includes 8' Curb Stop) AQ EA 1 101400-2 Signs AQ EA 1

033000-1 Concrete Waterway LSQ LS Lump Sum 260500-4 Electrical Feeder Spur (bunkhouse #4) LSQ LS Lump Sum

033000-2 Concrete Sidewalks DQ LF 440 Total Option "B":

101400-1 Signs AQ EA 2

133402-1 Water Service Box AQ EA 5 BID OPTION "C" - (GROUP SITE, HORSHOES AND FITNESS PAD)

133402-2 Utility Box with Pressure Reducing Valve AQ EA 1 033000-3 Concrete Pad (Group Site, 5-inch thick - includes Aggregate Base) DQ LS Lump Sum
Water Pipeline, 2" HDPE, 160 PSI with Heat Fusion Joints, Including Trench, Pipe
129300-1 Site Furnishings - Bicycle Rack (Includes Concrete Pad and Aggregate Base) AQ EA 4
221100-1 Zone and Bedding DQ LF 310
Water Pipeline, 2" HDPE with Frostshield, 160 PSI with Heat Fusion Joints, 129300-2 Site Furnishings - Wood Plank Picnic Table (Surface Mount) AQ EA 6
221100-2 Including Trench, Pipe Zone and Bedding DQ LF 120
Water Pipeline, 2" HDPE with 5" HDPE Sleeve, 160 PSI with Heat Fusion Joints, 129300-3 Site Furnishings - Pedestal Grill (Surface Mount) AQ EA 2
221100-3 Including Trench, Pipe Zone and Bedding DQ LF 35
Water Pipeline, 3" HDPE, 160 PSI with Heat Fusion Joints, Including Trench, Pipe 129300-4 Site Furnishings - Utility Table (Surface Mount) AQ EA 2
221100-4 Zone and Bedding DQ LF 150
322101 Horseshoe Pit (Includes Inverted Concrete Mow Strip) AQ EA 2
Water Pipeline, 3" HDPE with Frostshield, 160 PSI with Heat Fusion Joints,
221100-5 Including Trench, Pipe Zone and Bedding DQ LF 300
322105 Gravel Pad (For Fitness Structure - Includes Inverted Concrete Mow Strip) AQ EA 1

221100-6 Pumpout Drains AQ EA 6 Total Option "C":

221102 Curb Valve and Box - 2" Metal AQ EA 6


X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\03_G3.SOI.dwg, 3/3/2016 1:47:33 PM

221300-1 Sewerline - Gravity, 4" PVC, SDR 35, Including Trench DQ LF 570 BID OPTION "D" - (PLANTING AND IRRIGATION)

328000 Irrigation System LSQ LS Lump Sum


221300-2 Sewerline - Gravity, 4" PVC with Frostshield, SDR 35, Including Trench DQ LF 95
329204 Hydro-seeding LSQ LS Lump Sum
221300-3 Sewerline - Gravity, 4" PVC with 8" PVC Sleeve, SDR 35, Including Trench DQ LF 75
329212 Inverted Concrete Mow Strip Landscape Edger (Planting Beds) DQ LF 180
221300-4 4" Sewer Cleanout AQ EA 8
329215 Decorative Rock Mulch Gravel (Includes Fabric Underlayment) DQ CY 20
260500-1 Electrical Distribution System LSQ LS Lump Sum
329310-1 Exterior Plants LSQ LS Lump Sum
260500-2 Electrical Feeder Spur (bunkhouse #2) LSQ LS Lump Sum
329310-2 Topsoil (Hydro-seeded lawn areas - 2" Depth) DQ CY 4

312100 Project Site Preparation and Grading LSQ LS Lump Sum Total Option "D":

321204-1 Crushed Aggregate Surface Course - Grading G (For Road and Parking) DQ CY 370

321204-2 Crushed Aggregate Surface Course - Grading G (For Trench Road Repair) DQ CY 60

322622 Precast Concrete Curb Stops - 6-Foot AQ EA 32

323150 2-Foot High Post and Rail Fencing DQ LF 250

Total Base:
REMOVE AND DISPOSE OF HIGHWAY 93
EXISTING EVERGREEN TREE (1)
FOR NEW BUNKHOUSE

ABANDON POTABLE
WATER MAIN IN PLACE

EXISTING WATER SERVICE


EXISTING HOUSING TRAILER TO BE CONNECTION TO EXISTING
EXISTING HOUSING TRAILERS TO BE REMOVED REMOVED BY OTHERS. (SEE NOTE 2) WATER MAIN. COORDINATE
BY OTHERS PRIOR TO CONSTRUCTION ABANDONMENT OF EXISTING

VALLEY DRIVE
WATER MAIN WITH SHEET C2.

EXISTING IRRIGATION
EXISTING FENCE ALONG MAHHOLE/BOX TO REMAIN
VALLEY DRIVE TO REMAIN

EXISTING IRRIGATION LINE TO


REMAIN (SIZE/TYPE UNKNOWN)

REMOVE AND DISPOSE OF


EXISTING FENCE AROUND
PARKING AREA

ABANDON POTABLE
WATER MAIN IN PLACE

REMOVE AND DISPOSE OF


EXISTING EXERCISE
STRUCTURE AND EQUIPMENT

RIP AND REGRADE PORTIONS OF


EXISTING PARKING AREA TO BE
RESTORED TO LAWN.
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\05.DE1.Challis.Demolition.dwg, 3/3/2016 1:25:47 PM

ABANDON POTABLE WATER MAIN IN PLACE


FROM THIS LOCATION TO WATER SERVICE
CONNECTION. COORDINATE WITH NEW
REMOVE AND DISPOSE OF BARRIER WATERLINE LOCATION ON SHEET C2.
LOGS (APPROX. 5 TOTAL) WHERE NEW
PARKING AREA IS TO BE CONSTRUCTED

EXISTING WATERLINE
DO NOT DISTURB

NOTES:

1. AN EXTENSIVE EFFORT HAS BEEN MADE TO LOCATE ALL POSSIBLE EXISTING UTILITY LINES FROM
RECORDS AND EVIDENCE IN THE FIELD, HOWEVER, THE COMPLETENESS OR ACCURACY OF THE
LOCATIONS SHOWN CANNOT BE GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR
ESTABLISHING THE LOCATION OF ALL EXISTING UTILITIES. ANY LOCATION STAKED OR SHOWN IS
APPROXIMATE. CALL 811 TO HAVE UTILITIES MARKED BEFORE BEGINNING CONSTRUCTION. IF
CONFLICTS ARE FOUND, NOTIFY THE CONTRACTING OFFICER.
2. EXISTING HOUSING UNITS TO BE REMOVED BY OTHERS. ONE HOUSING UNIT (NORTHERNMOST UNIT)
AND UTILITIES TO REMAIN UNTIL NEW BUNKHOUSES CAN BE OCCUPIED TO PROVIDE EMPLOYEE
HOUSING. COORDINATE WITH COR ON SEQUENCE OF WORK.
3. OBLITERATE AND SCARIFY TRAILER PADS AND AGGREGATE ROAD EDGE SHOULDERS TO MATCH
EXISTING GRADES.
4. DO NOT REMOVE OR DAMAGE ANY TREES UNLESS IT IS SPECIFICALLY DESIGNATED TO BE REMOVED.
5. REMOVE AND DISPOSE OF EXISTING TIMBER EDGERS AND AGGREGATE PATHS. SCARIFY AND
REGRADE THESE AREAS AND PARKING AREA (AS SHOWN ON THE DRAWINGS) FOR SEEDING.
6. WHERE ENCOUNTERED, REMOVE AND DISPOSE OF EXISTING WATER, SEWER AND GAS LINES TO A
DEPTH OF 12" BELOW FINISHED GRADE. CAP AND ABANDON REMAINDER IN PLACE. REMOVE ALL
HYDRANTS, SEWER CLEANOUTS, GAS LINES AND OTHER UTILITIES NEAR THE SURFACE.
FIRE HYDRANT AND CONNECTION
HIGHWAY 93 TO CHALLIS CITY WATER SYSTEM

GRADE AROUND PROPOSED DASHED LINE REPRESENTS


BUILDING AS SHOWN. SEE APPROXIMATE EDGE OF
NOTE 10 AND SHEET C5 POSITIVE DRAINAGE APRON
(TYP), SEE NOTE 2 ON SHEET C5
PROPOSED SIDEWALK
(NOT IN CONTRACT)
10'

VALLEY DRIVE
PROPOSED
SHOWER
BUNKHOUSE #2 5%
HOUSE
MIN.
(NIC)

5%
BUNKHOUSE #3 MIN.
SEE SHEET C5 FOR SITE
GRADING REQUIREMENTS IRRIGATION SUPPLY
EXISTING IRRIGATION LINE TO FROM EXISTING WELL
REMAIN (SIZE/TYPE UNKNOWN)
BUNKHOUSE #1

BUNKHOUSE #4

INSTALL NEW SEWERLINE


SEE SHEET C3
EXISTING CITY MANHOLE
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C1-C5.Challis.Civil.dwg, 3/1/2016 6:42:38 PM

INSTALL NEW WATERLINE


SEE SHEET C2

NOTES:
EXISTING BUILDINGS (TYP)
1. SEE SHEET C2 FOR WATERLINE PLAN AND PROFILE.
INSTALL NEW ROAD
2. SEE SHEET C3 FOR SEWERLINE PLAN AND PROFILE
AND PARKING AREAS
3. SEE SHEET C4 FOR ROAD AND PARKING AREA PLAN AND PROFILE
SEE SHEET C4
4. SEE SHEET C5 FOR GRADING PLAN.
5. LOCATION AND ORIENTATION OF ALL STRUCTURES SHALL BE APPROVED BY THE
CONTRACTING OFFICER PRIOR TO INSTALLATION.
6. AN EXTENSIVE EFFORT HAS BEEN MADE TO LOCATE ALL POSSIBLE EXISTING UTILITY
LINES FROM RECORDS AND EVIDENCE IN THE FIELD, HOWEVER, THE COMPLETENESS OR
ACCURACY OF THE LOCATIONS SHOWN CANNOT BE GUARANTEED. THE CONTRACTOR IS
RESPONSIBLE FOR ESTABLISHING THE LOCATION OF ALL EXISTING UTILITIES. ANY
WATERLINE CONTINUES TO ENGINEERING LOCATION STAKED OR SHOWN IS APPROXIMATE. CALL 811 TO HAVE UTILITIES MARKED
BUILDING AND ENGINE BAY (NOT SHOWN) BEFORE BEGINNING CONSTRUCTION. IF CONFLICTS ARE FOUND, NOTIFY THE
CONTRACTING OFFICER.
7. CLEARING LIMITS SHALL BE AS FOLLOWS:
7.1. 5 FEET ON BOTH SIDES OF THE WATER OR SEWER LINE TRENCHES
7.2. 10 FEET FROM EDGE OF CUT/FILL LINES FOR ROAD AND PARKING AREA
7.3. 10 FEET FROM EDGE OF BUILDING, PATIOS, PATHS OR OTHER CONSTRUCTED
FEATURES.
7.4. THE CONTRACTOR SHALL USE CAUTION AND AVOID DAMAGE TO TREES AND
VEGETATION. THE CONTRACTOR SHALL CONFINE ALL OPERATIONS AND ACTIVITIES
TO WITHIN THE CLEARING LIMITS.
8. CONSTRUCTION POINT ABBREVIATIONS ARE AS FOLLOWS:
8.1. CP = CONTROL POINT
8.2. FG = FINISHED GRADE
8.3. PATH CL = PATH CENTERLINE
9. IF BUNKHOUSES #3 OR #4 ARE NOT CONSTRUCTED (SEE OPTIONS IN COST ESTIMATE AND
SPECIFICATION SECTION C):
9.1. CAP WATER AND SEWERLINES AT PROPOSED BUILDING EDGE AND INSTALL 12" X 12"
CONCRETE PAVER AT GROUND TO MARK CAP LOCATION.
9.2. GRADE AROUND PROPOSED BUILDING AS SHOWN AND INSTALL PARKING, CURB
STOPS, SIGNS, AND SIDEWALK AS SHOWN.
10. THE PROPOSED SHOWERHOUSE IS NOT IN CONTRACT.
10.1. CAP WATER AND SEWERLINES AT PROPOSED BUILDING EDGE AND INSTALL 12" X 12"
CONCRETE PAVER AT GROUND TO MARK CAP LOCATION.
10.2. GRADE AROUND PROPOSED BUILDING AS SHOWN.
NOTES: INSTALL 2 FOOT SECTION OF 2"
WATERLINE CONTINUES TO ENGINEERING HDPE, 2" CURB VALVE AND BOX, AND
1. NOTES AND LEGEND ON SHEET C1 APPLY. BUILDING AND ENGINE BAY (NOT SHOWN) CONNECT TO EXISTING WATERLINE
2. ALL WATERLINE SHALL BE SLOPED A MINIMUM 1% TO DRAIN.
3. BURY WATERLINE A MINIMUM OF 60 INCHES. ADDITIONAL DEPTH MAY BE REQUIRED TO
MAINTAIN A MINIMUM SLOPE OF 1%. INSTALL 2" CURB VALVE AND
4. THE MINIMUM ALLOWABLE BENDING RADIUS FOR HDPE PIPE IS 30 TIMES THE NOMINAL BOX AND PUMPOUT DRAIN
PIPE DIAMETER.

NOM. PIPE DIA. MIN. BENDING RADIUS


2" 5'-0"
3" 7'-6"

2"
INSTALL 2" CURB

HD
5. INSTALL THE WATER SYSTEM ACCORDING TO APPLICABLE FEDERAL, STATE AND LOCAL VALVE AND BOX

PE
REGULATIONS FOR PUBLIC DRINKING WATER SYSTEMS.
6. CONNECTIONS BETWEEN NEW AND EXISTING WATERLINES SHALL BE INSTALLED IN
MANNER RECOMMENDED BY THE PIPE MANUFACTURER AND APPROVED BY THE EXISTING ROAD EDGE (TYP)
CONTRACTING OFFICER. USE HDPE/GSP TRANSITION FITTINGS FOR CONNECTIONS TO
GALVANIZED STEEL. USE HDPE/PVC TRANSITION FITTINGS FOR CONNECTIONS TO PVC INSTALL 2" HDPE
PIPE. COMPRESSION-TYPE FITTINGS ARE NOT ALLOWED. LATERAL, TYP
7. ON LATERALS AND DRAINLINES, INSTALL CURB VALVES AND BOXES 2 FEET FROM TEE OR
LINE TO BE DRAINED UNLESS SHOWN OTHERWISE.
8. ALL LATERALS BETWEEN THE WATER SERVICE BOX AND BUILDING CONNECTIONS SHALL BUNKHOUSE #4
BE 2" HDPE. INSTALL 2" CURB
9. WHERE NEW WATERLINES INTERSECT SEWERLINES AND NON-POTABLE IRRIGATION VALVE AND BOX
LINES, THE NEW WATERLINES SHALL BE INSTALLED ACCORDING TO APPLICABLE CONNECT TO NEW BUILDING (TYP)
FEDERAL, STATE AND LOCAL REGULATIONS, INCLUDING IDAHO DEQ IDAPA 58.01.08, SEE NOTE 9 ON SHEET C1.
RULES FOR PUBLIC DRINKING WATER SYSTEMS. ADJUST WATERLINE INVERT
ELEVATIONS AND GRADES IF NECESSARY TO AVOID AN EXISTING OR PROPOSED SEWER
PE
OR IRRIGATION LINE, WHILE MAINTAINING 1% MINIMUM GRADES FOR DRAINAGE. HD INSTALL WATER SERVICE BOX
10. DO NOT INSTALL HYDRANTS, PRESSURE REDUCING VALVES OR ANY OTHER PLUMBING IN 3" (TYP), SEE DETAIL ON SHEET C8
THE UTILITY BOXES OR BUILDINGS UNTIL THE UPSTREAM WATERLINES HAVE BEEN FULLY
FLUSHED OF DEBRIS ACCORDING TO THE SPECIFICATIONS. BUNKHOUSE #1
11. ROUTE NEW WATERLINES OUTSIDE OF THE DRIPLINES OF NEW AND EXISTING TREES AS
SHOWN. IF CONFLICTS OCCUR, NOTIFY THE CONTRACTING OFFICER.
12. THE PROPOSED SHOWERHOUSE IS NOT IN CONTRACT. CAP WATER AND SEWERLINES AT SPECIAL CONSTRUCTION APPLIES
PROPOSED BUILDING EDGE AND INSTALL 12" X 12" CONCRETE PAVER AT GROUND TO CAP WATER AND SEWERLINES WHERE WATERLINE INTERSECTS NEW
MARK CAP LOCATION. AT PROPOSED BUILDING EDGE. AND EXISTING SEWERLINES AND 2" HDPE
BUNKHOUSE #3
SEE NOTE 12. IRRIGATION LINE, SEE NOTE 9 AND
INSTALL 2" CURB DETAIL ON SHEET C7.
VALVE AND BOX IF NECESSARY, REROUTE
PROPOSED WATERLINE TO WEST TO
SHOWER SPECIAL CONSTRUCTION APPLIES WHERE AVOID PORCH FOUNDATIONS
BUNKHOUSE #2
HOUSE WATERLINE INTERSECTS NEW AND EXISTING BY AT LEAST 5 FEET. SUBMIT
(NIC) SEWERLINES, SEE NOTE 9 AND DETAIL ON SHEET C7. REROUTE TO CONTRACTING
INSTALL 2" CURB VALVE OFFICER FOR APPROVAL.
AND BOX AT LEAST 2 FEET
E
3" HDP FROM EDGE OF PATHWAY
INSTALL 2" HDPE SERVICE LATERAL. SLOPE
CONNECT TO EXISTING WATER SERVICE LATERAL TO DRAIN TOWARDS WATER
AT METER AND INSTALL UTILITY BOX WITH SERVICE BOX AND PUMPOUT DRAIN
PRESSURE REDUCING VALVE. SEVER AND
CAP EXISTING WATERLINE TO HOUSING
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C1-C5.Challis.Civil.dwg, 3/1/2016 6:42:51 PM

5170
INSTALL 4" PVC LATERAL PROPOSED
AND CLEANOUT (TYP) SHOWER
BUNKHOUSE #2 HOUSE
(NIC)
INSTALL SEWERLINE IN 8" PVC
SLEEVE UNDER CONCRETE PAD
BUNKHOUSE #3 (APPROX. 30' REQUIRED) CAP WATER AND SEWERLINES
AT PROPOSED BUILDING EDGE. SPECIAL CONSTRUCTION APPLIES WHERE NEW
SEE NOTE 8. SEWERLINE INTERSECTS NEW WATERLINE, SEE
NOTE 6 AND DETAIL ON SHEET C7

4"
PV
BUNKHOUSE #1 C SPECIAL CONSTRUCTION APPLIES WHERE NEW SEWERLINE

4"
INTERSECTS EXISTING CITY SEWER MAIN, AND POSSIBLY THE

PV
INSTALL NEW CLEANOUT (TYP), EXISTING IRRIGATION LINE. FOLLOW DETAIL ON SHEET C7

4"

C
SEE DETAIL ON SHEET C7

PV
REGARDING SUPPORTING PIPES. IF LESS THAN 18" BETWEEN
4" PVC

C
BEGIN SEWERLINE ALIGNMENT PIPES, FILL WITH CONCRETE TO SUPPORT UPPER PIPE.
4" PVC
EXISTING CITY SEWER MAIN,
DO NOT DISTURB

C EXISTING CITY MANHOLE


BUNKHOUSE #4 PV
4" 4" PVC
SPECIAL CONSTRUCTION APPLIES WHERE NEW
SEWERLINE INTERSECTS NEW WATERLINE, SEE
NOTE 6 AND DETAIL ON SHEET C7 CONNECT TO NEW BUILDING (TYP)
SEE NOTE 9 ON SHEET C1. SPECIAL CONSTRUCTION APPLIES WHERE NEW
SEWERLINE INTERSECTS NEW WATERLINE, SEE
NOTE 6 AND DETAIL ON SHEET C7

IDENTIFY AND CONNECT TO SEWERLINE


EXISTING ROAD EDGE (TYP) FROM EXISTING HOUSING WITHIN 5 FEET
OF THE EXISTING MANHOLE, SEE NOTE 7

NOTES:

1. NOTES AND LEGEND ON SHEET C1 APPLY.


2. ALL SEWERLINE SHALL BE SLOPED A MINIMUM 1%
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C1-C5.Challis.Civil.dwg, 3/1/2016 6:43:05 PM

TO DRAIN.
3. BURY SEWERLINE A MINIMUM OF 48 INCHES.
ADDITIONAL DEPTH MAY BE REQUIRED TO MAINTAIN
A MINIMUM SLOPE OF 1%.
4. INSTALL THE SEWER SYSTEM ACCORDING TO
APPLICABLE FEDERAL, STATE AND LOCAL
REGULATIONS FOR WASTEWATER SYSTEMS.
5. INSTALL CLEANOUTS ON SEWERLINES AT
INTERVALS NOT TO EXCEED 200 FEET AND AT EACH
CHANGE IN DIRECTION. CLEANOUTS ARE ALSO
REQUIRED WITHIN 10 FEET OF EACH BUILDING
CONNECTION.
6. WHERE NEW SEWERLINES INTERSECT
WATERLINES, THE SEWERLINE SHALL BE INSTALLED
ACCORDING TO APPLICABLE FEDERAL, STATE AND
LOCAL REGULATIONS, INCLUDING IDAHO DEQ IDAPA
58.01.08, RULES FOR PUBLIC DRINKING WATER
SYSTEMS.
7. CONTRACTOR SHALL IDENTIFY THE EXISTING
SEWERLINE PIPE FROM THE EXISTING HOUSING.
VERIFY THAT EXISTING PIPE IS NOT SMALLER IN
DIAMETER THAN THE NEW SEWERLINE. IF THE
EXISTING PIPE IS SMALLER, THEN A NEW
CONNECTION TO THE MANHOLE IS NECESSARY.
COORDINATE WITH THE CONTRACTING OFFICER
AND THE CITY OF CHALLIS FOR MANHOLE
CONNECTION REQUIREMENTS.
8. THE PROPOSED SHOWERHOUSE IS NOT IN
CONTRACT. CAP WATER AND SEWERLINES AT
PROPOSED BUILDING EDGE AND INSTALL 12" X 12"
CONCRETE PAVER AT GROUND TO MARK CAP
LOCATION.
BUNKHOUSE #2

BUNKHOUSE #3

HATCHED AREA TO BE RESURFACED


WITH 6" AGGREGATE, GRADING "G"
BUNKHOUSE #1

15'
CUT CATCHLINE (TYP)

15'
25' 25'
INSTALL 6' WHEEL STOP AT ALL

10'

0'
PARKING STALL LOCATIONS SHOWN, END ROAD AND
SEE DETAIL ON SHEET D4 R5' PARKING ALIGNMENT
BUNKHOUSE #4 CONSTRUCT SMOOTH
TRANSITION TO

0'
EXISTING ROADWAY

R1
3'

R1

'
9' WIDE STALLS, TYP

R10
0'
4'

SLOPE
2% CROSS

SLOPE
2% CROSS

40'
3'
47'
DO NOT LINE STRIPE. LINE STRIPING 10'
SHOWN FOR CLARITY ONLY (TYP)

54'
5'
R1

R6 4
R3'

SLOPE
2% CROSS

'
4'

2%
'
R5
BEGIN ROAD AND

20'

R1
25'

25'
6'

6'
PARKING ALIGNMENT

2%

00
'
R3'
MATCH NEW ROAD FINISHED SURFACE
TO EXISTING ASPHALT ROAD EDGE

12'
38'

R50'
R1
5'
EDGE OF TRAVELWAY (TYP),
FILL CATCHLINE (TYP)
EDGE OF SHOULDER NOT
SHOWN FOR CLARITY ROAD AND PARKING
INSTALL 36' LONG ALIGNMENT CENTERLINE
CONCRETE WATERWAY,
SEE DETAIL ON SHEET C9
NOTES:

1. NOTES AND LEGEND ON SHEET C1 APPLY.


X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C1-C5.Challis.Civil.dwg, 3/1/2016 6:43:20 PM

2. ALL CLEARING AND GRUBBING SHALL CONFORM TO


SHEET C1 AND SECTION 311000 IN THE SPECIFICATIONS.
3. ROAD AND PARKING GRADING:
3.1. ALL CUT SHALL BE SLOPED AT 2:1.
3.2. ALL FILL SLOPES SHALL BE SLOPED AT 3:1.
4. SEE SHEET C6 FOR TYPICAL ROAD TEMPLATE.
5. SEE "S" SHEETS AND SHEET D5 FOR REGULATORY
SIGNS.
6. ALL CONSTRUCTION POINT ELEVATIONS PROVIDED ARE
FINISHED GRADE.
7. CONSTRUCTION POINT ABBREVIATIONS ARE AS
FOLLOWS:
7.1. EOR: EDGE OF ROAD
7.2. CL: ROAD AND PARKING ALIGNMENT CENTERLINE
7.3. WATERWAY CL: WATERWAY CENTERLINE
7.4. FG-ROAD: FINISHED GRADE WITHIN ROADWAY
8. TOTAL PARKING STALLS: 32
9. THE CONTRACTOR SHOULD EXPECT TO HAVE A
SUBSTANTIAL AMOUNT OF WASTE ROCK FROM
EXCAVATION.
10. EXCESS EXCAVATED MATERIAL AND UNSUITABLE
MATERIAL FROM EARTHWORK ACTIVITIES SHALL BE
SPREAD ON SITE AS DIRECTED BY THE CONTRACTING
OFFICER.
11. ESTIMATED EARTHWORK QUANITITES:
11.1. ROAD AND PARKING: 115 CY CUT, 170 CY FILL.
INCREASE GRADE AROUND NOTES:
BUILDING AS NECESSARY IN ORDER TO PROTECT TREES ON THE UPHILL SIDE,
TO ENSURE POSITIVE MODIFY SWALE AND GRADING AS FOLLOWS: SLOPE 1. NOTES AND LEGEND ON SHEET C1 APPLY.
DRAINAGE FOR SWALE BUILDING AT 5% FOR 5' TO SWALE. SWALE MUST HAVE A 2. GENERAL GRADING NOTES
SLOPE OF 2% MINIMUM WHEN LESS THAN 10' FROM THE 2.1. CREATE POSITIVE DRAINAGE "APRON" AROUND BUILDING PERIMETER. GRADE
BUILDING EDGE. AWAY FROM BUILDING FOUNDATION AT 5% MIN. FOR 10 FEET IN ALL DIRECTIONS.
INCREASE GRADE AROUND SLOPE CONCRETE SURFACES IN THIS AREA AT 2%
5%
BUILDING AS NECESSARY 2.2. CUT AND FILL SLOPES AROUND BUILDING PERIMETER SHALL BE SLOPED AT A

5'
MIN.
CONSTRUCT DRAINAGE TO ENSURE POSITIVE MAXIMUM OF 4:1. BLEND PROPOSED AND EXISTING GRADES BY CREATING
SWALE, SEE NOTE 6 DRAINAGE FOR SWALE SMOOTH TRANSITIONS.
2.3. PATHWAY GRADES AND CROSS SLOPES TAKE PRECEDENCE OVER BUILDING
GRADING, WHERE THE TWO OVERLAP.
CONSTRUCT DRAINAGE 3. GRADING OF PATHWAYS BETWEEN THE PARKING AREA AND BUILDING SHALL BE AS
5% SWALE, SEE NOTE 6 FOLLOWS:
BUNKHOUSE #2 MIN. 3.1. CROSS SLOPES: 2% FOR DRAINAGE, AWAY FROM BUILDING.
FFE: 5172' 3.2. RUNNING SLOPES: MAXIMUM GRADE OF 8.33% (5% MAXIMUM PREFERRED)
5% 3.3. CONSTRUCT LANDINGS AS SHOWN. LANDINGS SHALL BE 5' X 5' WITH A MAXIMUM
MIN. GRADE OF 2% IN ANY DIRECTION.
4. ALL CONSTRUCTION POINT ELEVATIONS PROVIDED ARE FINISHED GRADE. FOR
5%

5'
PATHS, ONLY ELEVATIONS THAT ARE CRITICAL FOR RUNNING SLOPE GRADES HAVE
10' MIN.
BEEN INCLUDED.
5. CONSTRUCTION POINT ABBREVIATIONS ARE AS FOLLOWS:
5.1. FG: FINISHED GRADE AT BUILDING CORNERS
5%
5.2. PATH CL: PATH CENTERLINE
CONSTRUCT DRAINAGE MIN.
6. DRAINAGE SWALE SHALL BE CONSTRUCTED WITH A MINIMUM GRADE OF 0.5%. AND 1:3
SWALE, SEE NOTE 6
5% OR LESS STEEP SIDE SLOPES. CONSTRUCT SWALE TO DIRECT WATER AWAY FROM
BUNKHOUSE #3 MIN. THE BUILDING.
FFE: 5172' 7. THE CONTRACTOR SHOULD EXPECT A SUBSTANTIAL AMOUNT OF WASTE ROCK FROM
5% EXCAVATION.
MIN. 8. ESTIMATED EARTHWORK QUANTITIES:
8.1. BUNKHOUSE #1: 130 CY CUT, 60 CY FILL
5%
10'

8.2. BUNKHOUSE #2: 160 CY CUT, 30 CY FILL


MIN. 10'
8.3. BUNKHOUSE #3: 105 CY CUT, 60 CY FILL
8.4. BUNKHOUSE #4: 140 CY CUT, 50 CY FILL
5% 8.5. GROUP AREA: 0 CY CUT, 1 CY FILL
BUNKHOUSE #1 MIN. 8.6. SHOWERHOUSE: 0 CY CUT, 82 CY FILL
9. SHOWERHOUSE GRADING IS SHOWN ON SHEET C1.
FFE: 5170.5'
CONSTRUCT 5' X 5' CONCRETE
LANDING AT BOTTOM OF 5%
CONCRETE RAMP, MAXIMUM MIN.
SLOPE OF 2%, SEE SHEET S2.
5%

PE
MIN.

LO
FINISHED GRADE TO BE FLUSH

SS
WITH TOP OF CONCRETE ALONG
EDGE OF RAMP

OS
10'

CR
2%
5%
MIN.
CONSTRUCT DRAINAGE
SWALE, SEE NOTE 6

ADDITIONAL STEPS REQUIRED,


SEE NOTE 2.3 SEE SPECIFICATIONS
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C1-C5.Challis.Civil.dwg, 3/1/2016 6:43:33 PM

5%

10'
MIN.

BUNKHOUSE #4
FFE: 5169.5'
CONSTRUCT 5' X 5' CONCRETE
LANDING AT BOTTOM OF 5%
MIN. DASHED LINE REPRESENTS
CONCRETE RAMP, MAXIMUM APPROXIMATE EDGE OF
SLOPE OF 2%, SEE SHEET S2. POSITIVE DRAINAGE APRON
5%
MIN. (TYP), SEE NOTE 2
FINISHED GRADE TO BE FLUSH
WITH TOP OF CONCRETE ALONG
EDGE OF RAMP
10'

5%
MIN.
ADDITIONAL STEPS REQUIRED,
SEE SPECIFICATIONS
SEE NOTE 2.3

2%
2%

TOP OF SIDEWALK ELEVATION TO MATCH TOP OF


AGGREGATE PARKING WHERE THE TWO MEET (TYP)
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C6.Challis.Valve.Trench.RoadCrossSection.dwg, 3/1/2016 6:43:53 PM
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C7.Challis.Water-SewerSeparation.Cleanouts.dwg, 3/1/2016 6:44:09 PM

2-4" CLEARANCE
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C8.Challis.WaterServiceBox.dwg, 3/1/2016 6:44:24 PM
X:\SalmonChallis\ChallisSeasonalHousing.2015\DWG\C9.Challis.Waterway.PRV.Box.dwg, 3/1/2016 6:44:39 PM

NOTES:
1. INSTALL CONTRACTION JOINTS EVERY 8' ON CENTER, 1/2" DEEP.
INSTALL EXPANSION JOINTS EVERY 50' ON CENTER.
2. LONGITUDINAL SLOPE OF WATERWAY SHALL MATCH ROAD CROSS
SLOPE, BUT SHALL BE NO LESS THAN 0.5% FOR DRAINAGE.

TOP OF CONCRETE TO
MATCH NEW ROAD SURFACE
72"
NEW ROADWAY ACCORDING

1.5"
36" TO ROADWAY DESIGN

8"

3"
6"
CRUSHED AGGREGATE GRADING "C" #4 REBAR AT 12" ON CENTER
IN BOTH DIRECTIONS
CONCRETE
COMPACTED NATIVE EARTH

CONCRETE WATERWAY
NOT TO SCALE
NOTES:

1. DEMOLITION INCLUDES ALL SHOWN AND INCLUDES


REMOVAL OF THE ABANDONED FEEDERS AND RELATED
EQUIPMENT.

1.1. SOME EXISTING FEEDERS ARE NOT LOCATED ON THE


SITE PLAN. NOT IN CONTRACT:
DISCONNECT AND
1.2. ADDITIONAL TELEPHONE LINES, NOT SHOWN, MAY REWORK FEEDER FROM
EXISTING TELEPHONE
EXIST. TELEPHONE LINES ENCOUNTERED MAY BE BUILDING
SERVICE TO BE
REMOVED. EXTERIOR TELEPHONE SERVICE TO BE BY
REMOVED BY
OTHERS IF INSTALLED.
OTHERS, MAY BE TO
OTHER EXISTING
2. NEW BUILDING FEEDER DISCONNECT LOCATIONS MAY
BUILDINGS TO BE
VARY. PROVIDE CORRECTED AS-BUILTS SHOWING
REMOVED REMOVE TWO
LOCATIONS OF ELECTRICAL FEEDERS AND EQUIPMENT.
ALUMINUM FEEDERS
3. EXISTING SPEED-D I-LINE PANEL (EXISTING SERVICE FROM I-LINE PANEL
FIBER OPTIC AND ALL CONNECTIONS
LOCATION) - DEMOLITION REMOVED CIRCUITS FROM 200
LINE(S) TO REMAIN WITH EQUIPMENT
AMP BREAKER AND 175 AMP BREAKER, ONE OR BOTH MAY
BE REMOVED TO MAKE ROOM FOR NEW 300 AMP BREAKER
TO FEED THE NEW BUNKHOUSES. THE BREAKER SHALL BE
NEW OR REMANUFACTURED SQUARE D Q422300AC, LA
TYPE ALSO ALLOWED BUT SHOULD BE VERIFIED THAT IT EXISTING METER
WILL MOUNT PROPERLY IN THE SWITCHBOARD. VERIFY AC PRIMARY TO REMAIN FOR
PHASE IN SWITCHBOARD BEFORE ORDERING. TRANSFORMER FOR FUTURE
OVERHEAD
TO REMAIN LAUNDRY BUILDING
PRIMARY TO
REMAIN
REMOVE ELECTRICAL 600 AMP SERVICE,
CONNECTION AND SPEED-D I-LINE PANEL,
FEEDER (TYPICAL) TO REMAIN

PRIMARY AND
SECONDARY LINES
TO REMAIN

FUTURE LAUNDRY BUILDING

NOT IN CONTRACT:
REROUTE AND EXTEND
AS NEEDED THE EXISTING
200 AMP FEEDER TO
LAUNDRY BUILDING NOT
IN CONTRACT

NEW HANDHOLE (TYP.


OF 2), FOR FUTURE
OR AWARDED
BUNKHOUSES

INSTALL NEW
BREAKER AS
CALLED FOR
A-15,17

A-16,18
A-1
A-6 A-8 A-8
A-1 A-10
A-1 A-1 A-6
A-10 A-11
A- 11
A-1 A-6
A-8 A-12,14
A-1 A-6 SERVES FLOOR
A-1
A-1
A-1
A-1 A-7 BUNKHOUSES INSTALLED AT THE CHALLIS
COMPOUND DO NOT REQUIRE METERBASES.
A-10
A-1 A-8 POWER SUPPLIED BY FOREST SERVICE OWNED
A-2 A-5 FEEDER. UNDERGROUND FEED.

MOUNT BOTH TV GENERAL ELECTRICAL NOTES:


A-9 A-9
CONNECTION AND
A-9 A-9 RECEPTACLE AT 48" TO 1. DEVICE LOCATIONS SHOWN ARE REPRESENTATIVE OF REQUIRED
CENTER ABOVE PLACEMENT AND QUANTITY.
A-19 A-19 FINISHED FLOOR. A-9
A-4 2. RANGEHOOD IN ADA UNIT SHALL BE WIRED AS DESCRIBED TO
TAMPER SWITCH S
DOUBLE SWITCH IN CABINET FRONT.
AND FLOW SENSOR
A-19 A-19 A-19 A-19 ACTIVATE BELL ONLY
S

A-19 A-19

A-19 A-19 A-9


A-9 SPRINKLER FLOW
ALARM BELL

A-19

GENERAL ELECTRICAL NOTES


LOAD CENTER DISTRIBUTION (update needed) 1. ELECTRICAL FEEDERS SHALL BE KEPT 36-INCHES FROM WATER OR GAS
SERVICES. LOCATE TO AVOID FUTURE FOUNDATIONS BY 10-FEET
THE FOLLOWING IS A LIST OF COMMON CIRCUITS MINIMUM: MINIMUM.
# AMPS DESCRIPTION
SERVICE CALCULATIONS A-1 20 REAR BEDROOMS LIGHTS AND 2. ELECTRICAL LOAD CENTERS SHALL BE EQUIVALENT TO SQUARE D QO OR
NEC 220.82 RECEPTACLES AND EXTERIOR BETTER, NO TANDEM OR HALF SIZED BREAKERS ALLOWED.
M
RECEPTACLES
3. HOME RUN INTERNAL PHONE TO MAIN DISCONNECT LOCATION INTO
(3VA/FT2)(1570FT2)= 4,710 A-19 20 FRONT BEDROOMS LIGHTS AND
COMBINER/SERVICE BOX. GROUND PER CODE AND SPECIFICATIONS.
(1.5KW)(3 SMALL APPL)= 4,500 RECEPTACLES AND EXTERIOR
(1.5KW)(1 LAUNDRY)= 1,500 RECEPTACLES 4. HOME RUN TELEVISION INTERNAL CABLE TO SURGE ARRESTOR MOUNTED
2 REFRIGERATORS= 1,200 A-2 20 RECEPTACLE-SMALL BATHROOM NEAR MAIN DISCONNECT LOCATION FOR CABLE TV OR SATELLITE S
ECONOMIZER= 1,500 A-3 20 ALL LIGHTS AND FANS EXCEPT BEDROOMS SERVICE. GROUND PER CODE AND SPECIFICATIONS.
DRYER= 5,000 A-4 20 RECEPTACLE-LARGE BATHROOM
2 RANGES LOAD= 24,000 A-5 20 LEFT FRIDGE AND RANGE HOOD 5. ELECTRICAL IN HOUSING SHOWN IS A MINIMUM AND MAY VARY BASED ON S
A-6 20 RECEPTACLES-KITCHEN LEFT WALL SUBMITTED FLOOR PLANS. IF ALTERNATIVE SIZED BUILDING IS
WATER HEATER= 4,500
A-7 20 RIGHT FRIDGE AND RANGE HOOD APPROVED, ELECTRICIAN SHALL SUBMIT MODIFIED ELECTRICAL PLAN.
TOTAL VA= 46,910
A-8 20 RECEPTACLES-KITCHEN REAR WALL AND ADDITIONAL LUMINAIRES AND OR TYPE CHANGES MAY BE REQUIRED AT
NO ADDITIONAL COST TO PROVIDE THE SAME LEVEL OF SERVICE.
10,000 @ 100% 10,000 PENINSULA
ADDITIONAL RECEPTACLES MAY ALSO BE REQUIRED TO MEET INTENT AS
S
36,910 @ 40% 14,764 A-9 20 RECEPTACLES-LIVING ROOM AND HALL
A-10 20 RECEPTACLES-DINING AREA SHOWN.
HEAT 13,500 @ 40% 5,400
TOTAL VA= 30,164 126 AMPS A-11 20 RECEPTACLE-WASHER 6. SMOKE AND VISUAL ALARMS SHALL ALL BE INTERCONNECTED.
A-12,14 30 RECEPTACLE-DRYER
OTHER LOADS THAT SHALL BE INCLUDED: A-13 15 SMOKE ALARMS, ALARM BELL CIRCUIT
FURNACE MOTOR @ 100% or ind at 40% A-15,17 50 SOUTH RANGE
A/C CONDENSERS @ 100% A-16,18 50 NORTH RANGE
A-20 20 ECONOMIZER (SEE "M" SHEETS)
SERVICE, MAIN BREAKER AND PANEL SHALL BE 200 AMP A-21,23 30 WATER HEATER
MINIMUM 120/240 VAC SINGLE PHASE. A-22,24 20 HEAT-REAR TWO BEDROOMS
A-25,27 15 HEAT-DINING AREA
PANEL SHALL BE LARGE ENOUGH TO ACCOMMODATE 5 A-26,28 20 HEAT-BATHROOMS AND FRONT FAR
BLANK BREAKER SPACES BEYOND INSTALLED BREAKERS BEDROOM
FOR FUTURE FEEDER AND OTHER POSSIBLE LOADS. A-29,31 15 HEAT-LIVING AREA
A-30,32 20 HEAT-KITCHEN AND BEDROOM ACROSS
MAIN FEEDER FROM KITCHEN
NEC 220.84 A-33,34 BREAKER BASED SURGE ARRESTOR SUCH AS IF
FOUR DWELLINGS AT 30,164 VA @ 45% = 54,295 VA, 226 AMP SQUARE D QO2175SB OR HOM2175SB
(300 AMP BREAKER MIN.)
REQUIRED CRAWL SPACE AND ATTIC SPACE LIGHTING AND
RECEPTACLES AS DESCRIBED MAY BE PLACED ON OTHER
CIRCUITS.

CIRCUIT NUMBERING IS SCHEMATIC ONLY AND SHALL VARY


TO PUT SURGE ARRESTOR AND LARGE LOADS NEAR THE
MAIN BREAKER ON THE BUS BARS
SEE LEGEND FOR
MORE INFORMATION
FOR RANGEHOODS G

J J SS A-3
A-7 X
TYPE DESCRIPTION MANUFACTURER MODEL # LAMPS MOUNTING Qty NOTES:

A-5 S A-20 A
B
ROUND CLOSE TO CEILING LED
1X4 LED
INCON LIGHTING
LITHONIA
11911 26LED
LBL4LP835
LED
LED
SURFACE/CEILING
SURFACE/CEILING
4
4
A AE
H2750ICAT
C DOWN LIGHT HALO LED RECESSED/CEILING 5

B
A

B
ML5606830 691WB
E ROUND CLOSE TO CEILING LED INCON LIGHTING 11111 14LED LED SURFACE/CEILING 4

S
G SPOT LIGHT LITHONIA OFLR 6 MO BZ LED SURFACE/WALL 2
S N KEYLESS ANY (1) lLED SURFACE/CEILING 4 LED LAMP TO BE CREE A19P 60W 27K
S X EXIT SIGN LITHONIA EXG LED EL M6 LED BACK MOUNT 2
A-1
TOTAL 25
S F BATH FAN (NO LIGHT) BROAN AE50 CEILING 0
E BATH FAN (NO LIGHT)
FF BROAN AE80 CEILING 2
S IN ATTIC, REQUIRES DISCONNECT AT MOTOR INCLUDES OTHER
A-1 AE ECONOMIZER FAN SEE MECHANICAL FOR TYPE AND CONTROLS
EQUIPMENT PER MECHANICAL SHEETS
A-3 A-3
A-3 C
S

E C C
S M
M
FF S
A-3
CRAWL SPACES AND ATTIC SPACES LIGHTING AND RECEPTACLES
S A-19 A-3 S S A-19 C

B
S 1- AT CRAWL AND ATTIC ACCESS, INSTALL ONE GFCI RECEPTACLE AND SINGLE POLE PILOT SWITCH ON THE
S
CIRCUIT SERVING THE ROOM WITH THE ACCESS ONLY ACCESSIBLE FROM WITHIN THE SPACE.
E S
AE
A A 2- SWITCH SHALL CONTROL 2 TYPE "N" LUMINAIRES LOCATED TO LIGHT THE SPACE. LOCATIONS SHALL BE
FF A-20 APPROVED BY THE CONTRACTING OFFICER BEFORE INSTALLATION.
E C

X
SS A-3

T
TYPE DESCRIPTION MANUFACTURER MODEL # MOUNTING Qty NOTES:
C15 1.5KW FAN FORCED HEATER QMARK EFF4007* RECESSED/CEILING 4
A-25,27
- HEATERS SHALL BE CONTROLLED BY 240V PROGRAMMABLE
C20 2KW FAN FORCED HEATER QMARK EFF4004* RECESSED/CEILING 2
THERMOSTATS AS CALLED FOR.
A-22,24
T
W5 500W FAN FORCED HEATER QMARK CWH1157DSF* RECESSED/WALL 0 - HEATER SIZES SHALL BE AS NOTED, SET AS REQUIRED, DO NOT
W10 1KW FAN FORCED HEATER QMARK CWH1157DSF RECESSED/WALL 3 INCREASE OR DECREASE. *INDICATES DISCONNECT COIL(S)
- SIGN EACH THERMOSTAT "DO NOT CHANGE VACATION SETTING,
T5 563W FAN FORCED HEATER QMARK QTS1104* RECESSED/UNDER COUNTER 1
FOR USE WHEN WINTERIZING DWELLING."
A-22,24
TOTAL 10 T A-20
A-26,28
T
A-30,32 ECONOMIZER
PANEL
T A-29,31
T T T T
A-26,28 A-30,32
A-26,28
A-1
A-8 A-7 A-8 A-8
A-1 A-6
A-1 A-1 A-10 A-11
A-10
A- 11
A-1
A-16,18
A-17,19
A-1 A-6
A-1
A-1
A-1
A-1 A-15,17 BUNKHOUSES INSTALLED AT THE CHALLIS
A-6 COMPOUND DO NOT REQUIRE METERBASES.
A-1 A-10 POWER SUPPLIED BY FOREST SERVICE OWNED
A-5 FEEDER. UNDERGROUND FEED.

MOUNT BOTH TV
A-2 A-9 A-9
CONNECTION AND
A-9 A-9 RECEPTACLE AT 48" TO
CENTER ABOVE
A-19 A-19 FINISHED FLOOR. A-9
A-4
TAMPER SWITCH
AND FLOW SENSOR
A-19 A-19 A-19 A-19 ACTIVATE BELL ONLY
A-4
A-19 A-19

A-19 A-19 A-9


A-9 SPRINKLER FLOW
ALARM BELL

A-19

GENERAL ELECTRICAL NOTES


1. THE NOTES AND LEGEND ON THE ADA SHEET APPLY.
G
A-3
SS A-3
FOR RANGEHOODS TYPE DESCRIPTION MANUFACTURER MODEL # LAMPS MOUNTING Qty NOTES:

A-20 A ROUND CLOSE TO CEILING LED INCON LIGHTING 11911 26LED LED SURFACE/CEILING 4
J A-7 B 1X4 LED LITHONIA LBL4LP835 LED SURFACE/CEILING 4
A AE
H2750ICAT
C DOWN LIGHT HALO LED RECESSED/CEILING 5

B
A

B
ML5606830 691WB
E ROUND CLOSE TO CEILING LED INCON LIGHTING 11111 14LED LED SURFACE/CEILING 5

S
G SPOT LIGHT LITHONIA OFLR 6 MO BZ LED SURFACE/WALL 2
S J A-5 N KEYLESS ANY (1) 18W CFL SURFACE/CEILING 4
S TOTAL 24
A-1
F BATH FAN (NO LIGHT) BROAN AE50 CEILING 3
S FF BATH FAN (NO LIGHT) BROAN AE80 CEILING 0
IN ATTIC, REQUIRES DISCONNECT AT MOTOR INCLUDES OTHER
S F ECONOMIZER FAN (NO LIGHT) SEE MECHANICAL FOR TYPE AND CONTROLS
EQUIPMENT PER MECHANICAL SHEETS
A-3 A-1
E
A-3
S

A-3 A-3
C
C C
S

S M
F E M S
A-3
A-3
CRAWL SPACES AND ATTIC SPACES LIGHTING AND RECEPTACLES
S A-19 S S A-19 C

B
E S 1- AT CRAWL AND ATTIC ACCESS, INSTALL ONE GFCI RECEPTACLE AND SINGLE POLE PILOT SWITCH ON THE
S
CIRCUIT SERVING THE ROOM WITH THE ACCESS ONLY ACCESSIBLE FROM WITHIN THE SPACE.
E
F AE
A E A 2- SWITCH SHALL CONTROL 2 TYPE "N" LUMINAIRES LOCATED TO LIGHT THE SPACE. LOCATIONS SHALL BE
S A-20 APPROVED BY THE CONTRACTING OFFICER BEFORE INSTALLATION.
A-3
C
A-3
E
S
F
SS A-3

T
TYPE DESCRIPTION MANUFACTURER MODEL # MOUNTING Qty NOTES:
C15 1.5KW FAN FORCED HEATER QMARK EFF4007* RECESSED/CEILING 4
A-25,27
- HEATERS SHALL BE CONTROLLED BY 240V PROGRAMMABLE
C20 2KW FAN FORCED HEATER QMARK EFF4004* RECESSED/CEILING 2
THERMOSTATS AS CALLED FOR.
A-22,24
T
W5 500W FAN FORCED HEATER QMARK CWH1157DSF* RECESSED/WALL 2 - HEATER SIZES SHALL BE AS NOTED, SET AS REQUIRED, DO NOT
W10 1KW FAN FORCED HEATER QMARK CWH1157DSF RECESSED/WALL 1 INCREASE OR DECREASE. *INDICATES DISCONNECT COIL(S)
- SIGN EACH THERMOSTAT "DO NOT CHANGE VACATION SETTING,
T5 563W FAN FORCED HEATER QMARK QTS1104* RECESSED/UNDER COUNTER 3
FOR USE WHEN WINTERIZING DWELLING." A-26,28 A-22,24
TOTAL 12 T A-20
T

A-30,32 ECONOMIZER
PANEL
T A-29,31
T T T
A-30,32
A-26,28

A-26,28
T
ECONOMIZER
PANEL