DEPARTMENT OF PHYSIOLOGY (Specifications)
S.No. Name of Equipment QTY
01. ELECTRICAL E-8 STUDENT KYMOGRAPH (Superior Quality) :With special
heavy duty motor, Oil lapped gear system jerk free running instantaneous start 02
& stop clutch ,stainless steel spindle screw lift.15x15cm.cylinder.
ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
02. Myograph stand : 45 cm. High stainless steel upright heavy base. 02
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
03. DU-BIOS REYMOND INDUCTION COIL: On teak base with graduated scale. 02
Primary with 300 turns & secondary with 8000 turns. With helm halts
modification of naïf, hammer & heavy duty platinum contact.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
04. SIMPLE KEY : On vulcanite base chrome finished. 02
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
05. SHORT CIRCULATING KEY 02
SWITCH TYPE With table clamp.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
06. POHL'S COMMUTATOR: With spill proof raised borders. 02
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
07. Vibrating Interrupter (Reed) 02
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
08. NEW NERVE MUSCLE CHAMBER (MUSCLE TROUGH): 17cm x 02
13cmx3cm. Perspex bath, cork lined bottom, pair of adjustable silver
electrodes, inter-changeable Muscle & Heart Lever fitments, clamp & drain.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
09. MUSCLE LEVER FOR THE USE WITH MUSCLE CHAMBER 02
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
10. Muscle grip of femur clamp 02
MUSCLE GRIP: With hole to fit 9 mm. Dia Upright.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
11. HOOK & WEIGHT: Hook 5 gm. Plus 10wts. 5 gm each total 55 gm. Set. all 02
brass.
HOOK & WEIGHT: Hook 1 gm. Plus 10wts. 1 gm. each total 11 gm. all brass.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
12. Heart lever (Simple & Starling) 02 each
PI 180 HEART LEVER:FITMENT FOR USE WITH HEART/NERVE MUSCLE
CHAMBER.
An ISO 9001:2015/13485:2016/GMP/OHSAS
1
18001:2007/CE/NSIC/MSME/BIFMA certified Co
13. frog board for dissection 02
FROG DISSECTION BOARD: 23cm x 15cm, fixing cork topped with elastic
band.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
14. Frog board cork-lined with boss-head 02
FROG BOARD: 15cm x 10cm, fixing cork topped with clamp & fork.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
15. Low voltage Unit for tapping 2 and 4 volts for stimulation 02
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
16. Electromagnetic time marker: 02
Coil wound round soft iron bar
Coil connected to screw
Soft iron plate with spring
Tension of screw can be regulated by screw
Writing lever attached to plate
Bar and holder to fix the instrument on stand
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
17. Tuning fork, N-100 with stylus. 02
Tuning Fork time Markers 100/sec.: Frequency -100Hz with attached pointer in
one of the Prongs
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
18. Von Frey’s hair Aesthesiometer: Metallic cylindrical instrument with 6
terminal thin hair like projection to test fine touch
19. Electrodes 02
Electrodes,
SIMPLE ELECTRODE Acrylic block with copper wire poles
Copper wire placed in holder made of nonconductive material (cork, Plastic
ect)
With screw
Shielded electrode two wire parallel to each other in layer of nonconductive
material
Polarizable or non-Polarizable electrode
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
20. X-blocks: a) Standard 02
b) Open side
STANDARD X BLOCK: Machined from solid brass rod, to hold 3/8” & 1/4".
Dia. Rods.
STANDARD X BLOCK: Machined from solid brass rod, to hold 1/2" &3/8”. Dia.
Rods,
OPEN SIDED X BLOCK: Machined from solid brass rod, to hold 1/8” to 1/2".
Dia. Rods.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
21. Watch Glasses: Medium sized concave glass troughs 40
22. Marey Tambour: 10
MAREY’S TAMBOUR: Stainless steel capillary lever,22 mm . Dia.
MAREY’S TAMBOUR: Stainless steel capillary lever,28 mm . Dia.
MAREY’S TAMBOUR: Stainless steel capillary lever,35 mm . Dia.
18001:2007/CE/NSIC/MSME/BIFMA certified Co
23. Staining Racks for DLC: Rectangular tubes fitted on ends with U shaped 40
connections to hold slides
2
24. Demonstration eye pieces: 10x Hyg.With pointer. 01
For the help of student to point out particular specimen.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
25. Double demonstration eyepiece: 02
The Demonstration Eye piece fits any standard 23 mm dia. Eye piece, making
it possible for two persons to see the same object the same time. Fitted with a
pointer. Magnification : 10X
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
26. STAGE INCUBATOR: 01
Complete with one hot plate with stainless steel top with energy regulator. The
slide with specimen is heated to pre determined temperature and then placed
on the microscope for culture studies. Complete with Hot Plate, Petri Dish and
Silde box of 50.
Temperature range should be 3°C above room temperature to 50°C
Temperature control accuracy should be as follows:
±0.3°C (Chamber temperature feedback)
±0.2°C (Specimen temperature feedback)
Electric Heating Technology
Chamber temperature feedback and Specimen temperature feedback
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
27. Westergen’s Pipettes with Stand for E.S.R (with spare pipettes) Spare 20
Pipettes:
Made from sheet metal and finished in white enamel, to hold micro
sedimentation tubes by placing the tube on the spring loaded tab on the base
and releasing to allow it to tighten against the corresponding tab on top of the
stand. Positions are numbered for easy identification.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
28. Wintrobe Pipette for ESR and PVC with stand: 20
Made from sheet metal and finished in white enamel paint
Wintrobe Stand is push type which can fit 6 tubes
Wintrobe Stand is a simple non specific screening test that indirectly measures
the presence of inflammation in the body associated with conditions such as
infections, cancers, and autoimmune diseases.
Wintrobe reflects the tendency of red blood cells to settle more rapidly in the
face of some diseases states because of increases in plasma fibrinogen,
immunoglobulins, and other acute-phase reaction proteins.Changes in red cell
shape or numbers may also affect the ESR
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
29. PERIMETER PRIESTLEY SMITH MODEL: The perimeter is an instrument 08
for accurate charting of the field of vision. It consists of: A vertical stand on
witch a metallic arc is pivoted. It also bear a circular black disc to read the
meridian in witch the arc in shape of a semicircle with radius 330 mm. Its
rotating in any direction and fix at any position with a tightening screw. The arc
is graduated from 0º to 90º with a movable test object which is a white colour
spot of size 10mm diameter painted on a circular disc it can be moved with
arc. An adjustable chin rest and a detachable leveling bar is fixed in front of the
metallic arc. A Scale and circular chart frame to hold the chart paper in
position is provided at the back of the circular disc. A metallic graduated scale
with a movable Pin-Punch pointer is fixed to mark on the perimeter chart
paper. Supplied With 100 charts.
ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
30. Haemoglobinometer (Sahli’s) or Hellige (with spaces):
Consists of comparator, hemoglobin tube, hemoglobin pipette, stirrer, Pasteur 30
pipette etc.,
3
The Haemoglobinometer Sahli’s type, square tube type and the kit should
consist of the following:-
· Comparator Holder –
1. It to be black in colour and the windows should have the following
dimensions :-
a. Height : 3 cms (Minimum)
b. Width: 0.5. cms (Minimum)
· Colour comparator
· Square Hb Tube graduated on both sides for measurement of haemoglobin
in percentage and gram %
· 20 MicolitreHb – Pipette
· Amber coloured acid vial
· Glass Stirrer
· Dropper with Teat
· Cleaning Brush
The kit supplied with the following standard accessories:
1. Square Hb tubes: 01 no.
2. Hb pipettes: 01 no.
3. HCL N/10: 500ml
4. Dropper: 01 no.
5. Glass stirrer: 01 no.
31. Haemocytometers with red (RBC) & white (WBC) pipettes: 30
With heavy cover slip; improved Neubauer counting chamber specialized
microscopic slide.
Inside cell of chamber: an area of 9sq.mm (3X3 Sq.mm) divided in to 9
squares of 01mm side by means of triple lines. The central small square is
further divided by triple lines into 5X5 = 25 smaller squares each with side 1/5
of a mm. each of the square is further divided in to 4X4=16 smallest squares
with side equal to one twentieth of a mm. Thus dimension of individual cell of
0.05X0.05X0.0025mm2
Gap between cover: 0.1mm, Slip Grid area.
Pipettes: RBC and WBC pipettes
Accessories: Rubber suckers for RBC & WBC pipettes
Cover Slips: 22x25mm one box
30 Lancets for Finger Prick: Lancets with sharp tips and plastic bodies as in 100000
routine glucometer needles
31. Capillary Glass Tubes for Clotting Time: Glass tubes with capillary bore, 5000 pieces
uniform throughout the length of the tube of standard length
34. Stethoscopes, Demonstration with multiple ear pieces: with multiple ear 05
pieces and common chest piece to facilitate teaching
35. Polygraph: 01
The system should be able to record and analyze,
Pulse transducer, blood pressure, ECG, EMG, EEG, Hand grip,
Heart & Lung sounds, Pulse Transit time, Heart Rate Variability
[HRV], Nerve Conduction Velocity, Sympathetic Skin response and
Valsalva Manoeuvre.
Respiratory belt should be DC based suitable for Stethography /
breath holding experiments.
ECG Multi leads configurations for real time cardiac axis & vector
analysis (to derive Lead III, aVl, aVf,aVr).
Event marker for reaction time, tendon hammer for reflex experiment
and wireless force / balance plate for sway and posture analysis
during HRV / EMG analysis.
Wireless HR sensor for Wireless HRV studies during yoga / sleep /
4
exercise.
Wireless sensors for ECG, Respiration, Heart Rate Variability, Skin
temp, PPG, Oxygen saturation, GSR, activity and body posture
recording during yoga / sleep studies. Operating range for wireless
sensors should be at least 100 meters or more, both online and
offline data recording up to 8-12 hours.
Hardware & Software Specifications:
4 channel Data Acquisition should have 16bits resolution and 100
KHz sampling rate perchannel.
Should have in built 2 channel universal bio amplifier for recording
ECG, EEG, EMG, EOG, Evoked potentials etc.
Should have software controlled in built fully Isolated Human safe
Constant current Stimulator with 0-20 mA current range.
The software should have step by step instructions, protocol and
experimental design for performing various experiments in physiology
applications. Also, should have sample data for animal experiments
for demonstrating to the students.
All-in-one software to record and analyse the above mentioned
parameters simultaneously both online and offline.
Facility for automatic online and offline analysis for ECG, Heart Rate
Variability, Blood Pressure, Peak analysis, Spectrum analysis etc.
Software should have complete heart rate variability analysis for Time
domain (Mean, SDRR, SDARR, CVRR, SDSD, RMSSD & pRR50 &
Frequency domain (VLF, LF, HF, Total Power, LF/HF Ratio and non-
linear measures of SD1 & SD2), Poincare plot and Power Spectrum
plot etc.
Software should have ECG analysis module to tabulate PQRST
amplitudes & intervals, QTc interval and super imposed waveform in
3D
Software should have option for video recording synchronized with
thedata.
Should have option for Mathematical function and Statistical analysis
and export options to other software like MATLAB, Excel, QuickTime,
Wav, Text etc. for desired interpretation of the data.
Software should offer OLE linking to MS Excel for automatic data
update.
The system should be supplied with latest computer with Windows10
OS, i5 Processer, 8 GB RAM, 21” monitor and 1 KVA UPS with
required accessories
Documentations like CE/FDA,ISO and there safety certificates must
be provided
Company should have local offices in India for on time support and
service
Non-Invasive Beat to Beat Blood pressure monitor for tilt table testing
(Optional) for future upgrade
36. Venus pressure apparatus: 01
Computerized recording unit along with software for recording and (desirable)
analysis of volumetric changes in arm
Should be supplied with comfortable air tight arm plethysmograph
chamber along with high sensitive volume transducer.
The chamber should be made up of clear Perspex and should take
care of subject comfort.
The systems should be supplied with necessary component for
performing blood flow/ volume changes from arm.
Should be supplied with arm cuff for occlusion and this pressure
should be recorded simultaneously with other signals.
The software should be robust and should perform automatic analysis
Should be supplied with compatible computer and laser b/w printer.
Machine Should be USFDA/CE/ BIS approved/CE declaration of
conformity/BIS/CDSCO.
Manufacturer should be ISO 9001 Certified.
5
37. SPIROMETER (Ordinary): 6 liter capacities for vital capacity, or use as a 10
gasometer with chain compensate counter balance to float through pulley,
calibrated to denote volume ,inlet& outlet tubes. Stainless steel chamber
,complete with corrugated rubber tube and mouth piece.
Spiro meter, Ordinary (6 liter with SS Float)
Water filled metallic double drum system, with leveling screws, pulley system
and corrugated tube – to facilitate lung volumes and capacities
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
38. Gas analyser Automatic for O2, Co2 , N2: 01
System should be able to record VO2, VCO2, Spirometry Flow / (desirable)
Volume, ECG & Wireless Heart Rate simultaneously.
The system should measure Respiratory Expenditure Ratio RER,
Resting Energy Expenditure, VE etc.
Should automatically generates a number of Metabolic graphs like VE
vs Time, VE vs VCO2, VCO2 vs VO2, RER vs Time, VCO2 vs Time,
VO2 vs Time etc.
System should be able to record lung function test (Tidal Volume,
Minute Ventilation, Respiratory rate, PIF, PEF, FVC, FEV1 etc.).
Software should generate automatic report with the metabolic values
and metabolic graphs mentioned above with Subjects details (Name,
age, Sex, weight, height) and environmental details.
Software should have complete heart rate variability analysis for Time
domain (Mean, SDRR, SDARR, CVRR, SDSD, RMSSD & pRR50 &
Frequency domain (VLF, LF, HF, Total Power, LF/HF Ratio and non-
linear measures of SD1 & SD2), Poincare plot and Power Spectrum
plot etc.
Software should have ECG analysis module to tabulate PQRST
amplitudes & intervals, QTc interval and super imposed waveform in
3D.
Should have high sensitive oxygen and carbon dioxide sensor with
adequate variable flow range for best performance and results.
CO2 Sensor O2 Sensor
Range: 0-10% CO2 Range: 0-100% O2
Resolution: 0.1% CO2 Resolution: 0.01% O2
The system should simultaneously record and analyse all the above
parameters in a single screen for interpretation and computation of
results.
Software should offer OLE linking to MS Excel for automatic data
update.
Should have a noise free wireless ECG, R-R interval, Heart Rate, Skin
temp, Respiration rate, Oxygen saturation and activity recording
integrated with metabolic parameters.
Operating range for wireless sensors should be at least 50 meters or
more, both online data recording and data logger mode up to 8-12
hours.
Software must generate customizable metabolic report with subject
details, environment settings along with tabulated parameters and
various metabolic graphs
The system should be provided with physical mixing chamber suitable
for extremely high and low ventilation ranges.
System should have video recording alongside the physiological data
and replay.
Accessories: - Face mask, head gear, tubing and flow sensors, mixing
chamber and disposable ECG electrodes to be provided.
It should be supplied with a suitable Treadmill with adjustable speed
and inclination facility.
The system should be supplied with latest computer with Windows10
OS, i5 Processer, 8 GB RAM, 21” monitor, Laser printer (B/W) and 1
KVA UPS with required accessories.
Manufacturer should have ISO certification for quality standards.
6
Should be US FDA/ European CE / IEC / BIS or other safety standards
approved product.
Demonstration of the equipment and necessary training to be provided
by the experts.
Principal company should have local offices in India with Trained
engineers for after sale support.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
39. Van Slyko’s apparatus manometric: 01
Van Slyko’s apparatus manometric (desirable)
Apparatus for analyzing gases in micro liter samples of blood or other solutions
Based on vacuum extraction principle
Should be accurate and reproducible
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
41. Douglas bag complete: 01
Made up of impervious flexible sheet Which can be placed on back of person (desirable)
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
42. BENEDICT ROTH RECORDING SPIROMETER [BMR APPRATUS]: For 01
determination of basal metabolism, by measurement of oxygen consumption. (desirable)
The 6 liter capacity float is fitted with chain compensated counter
balance. A thermometer is fitted on the float. movements of the float are
recorded by means of a gravity writing ink pen, adjustable by a lever at the
bottom. Valves are enclosed and are easily accessible .Soda lime container,
with screw connection in the center chamber. Drain cocks to all the tubes and
container. sampling cock is provided at the mouth-piece to connect the subject
to the spirometer or the atmosphere.
The recording cylinder (12”x 6”) is of the lift-off type, and is driven by an
electrical unit, giving two speeds viz :one revolution in 20 minutes, and one
rev. Nos 4 minutes. speed change through a lever. Pilot lamp to act as
indicator The unit is fitted on portable metal frame ,and is supplied complete
with valves, tubes ,mouthpiece, nose clip ,ink writing pen ,and 50 charts.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
43. MOSSO’S ERGOGRAPH: Mosso-ergograph- Computerised 10
The equipment is required to evaluate the physiological measures of
muscular contraction, fatigue, endurance, strength and physical capacity
or endurance. These tests were carried out under varying conditions, e.g.
with stimulants, narcotics, poisons, exercise and special diets. In
addition, experimenters measured the effects of mental tasks on physical
endurance.
Technical specification
ADC= 12 bits or more
The equipment should provide easy plug and play setup for
automatic recording and graphing and calculations relevant to
the study of muscular fatigue and human physiology.
Data is gathered using state-of-art force and ultrasonic sensors
for capturing isotonic and isometric forces as well as velocity
measurements, respectively.
Various levels of the hand rest available for different subjects
with different upper limb anatomies.
Should have a facility to caters to subjects with varying limb
length by providing multiple levels of adjustments for the hand
rest and providing different weights for subjects with different
muscular strength
Should measure the force applied during Isotonic and Isometric
contractions and Velocity measurements.
Wireless communication with the device and Bluetooth data
transfer.
7
The Software allows to plot different quantities against time or
other parameters Work done at a click of a button.
The recorded and analysed data for all subjects should be stored
and exported to a text file and a PDF file for reporting purposes.
Compatible computer or Tablet to be provided
wooden table top equipment to perform human fatigue experiments with
provision for finger holder, with weights each of 500gX6
44. Clinical thermometer Digital: Glass mercury thermometers to measure 30
temperature in Centigrade and Fahrenheit scales
45. COMPASS AESTHESIOMETER: Stainless steel/Brass, with well formed 6
points, and an adjusting screw giving movement of app: 1 mm per half turn
read on a scale.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
46. Thermanaesthesiometer: 6
HEAT & COLD SPOT HAMMER: double pointed, from stainless steel.
Make: LabotechTM
18001:2007/CE/NSIC/MSME/BIFMA certified Co
Metallic ‘T’ shaped instrument with 2 compartments (preferably insulated) to
hold and cold liquids to test temperature sensation
47. Algometer: 1
Algometer
Broad blunt knob attached to spring which can be pressed
With scale to measure pressure
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
48. Apparatus for Passive Movement: comprising of the following 01
CPM is used to treat joints of the lower limb after an injury, disease or (desirable)
following surgery. · Based on a concept originated by SALTER IN
1970, this device has varied applications namely treatment of intra-
articular fractures, septic arthritis, ligaments tendon healing and also
following total joint replacement to ensure a sufficient range of motion.
· To prevent stiffening, the joint have to be moved continuously which
results in the following. · Minimize swelling and pain after operation ·
Ensures faster recovery and shortened hospital stay · Prevents extra
articular contractures and adhesions. · Ext/Flex Angle indicator at
knee position · Compact and elegant construction · Electronic controls
enable all adjustment of angle to be made on the front panel. · Smooth
and silent movement · Digital timer with alarm · Patient safety switch
for stopping and reversing the motion.
Treatment time 0 – 99 minutes
Reset time 1 to 5 seconds
Angle Extension 0-110 degree
Power 230V/AC/50Hz, 75VA
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
49. Knee hammer: 30
Used to test joint reflexes or bone fractures in the joints. The Taylor hammer
features a 7.5 inch chrome handle and a triangular rubber head. The head
comes is several colors, so you can easily identify your own equipment.
Medical instrument used by practitioners to test deep tendon reflexes. Testing
for reflexes is an important part of the neurological physical examination in
order to detect abnormalities in the central or peripheral nervous system.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
50. PNEUMOGRAPH / STETHOGRAPH: Corrugated rubber tube with side clips 10
open link chain for use with any tambour.
60cm long and 2cms diameter corrugated and impervious tube made of
canvas with rubber one end closed other end open
8
Metal chain at both ends one chain with hook
Open end connected with pressure tube to tambour
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
51. BICYCLE Ergometer: 01
Work Load Range: 10 – 600Watt Independent Rpm: 20 – 130rpm Work Load
range Dependent RPM Lap Time: 9h 59min 59sec Load Steps : 1 – 99 Watt
Time Steps : 1 – 99 Min Load Programs: Manual 1 Load/Step PWC 170, 150,
130 HR Steady State Safety Protection Automatic Load: Heart rate Reduction:
Blood pressure Blood Pressure D Acoustic signal: ECG Alarm Signal Manual :
By Stop Button Check: Calibration Dynamic Static Adjustments (Height): 83cm
– 110cm Saddle: 68cm – 108mm Handle bars: free rotation Accuracy of load:
2% or 3 Watt Input/output External Control: RS – 232 Inputs: Analogue control
Start signal Heart rate Blood pressures Blood pressure D ECG Alarm Outputs:
work load Pedaling Speed Step Marker Power supply: 110 – 240V, 50 – 60Hz
Power consumption: 100VA Safety Standard: class 1, CE/BIS Dimensions
(cm): Base plate 79X48
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
52. Olfactometer: instrument with container to hold the given odorous solutions 01
attached with a sprayer and 4 standard odorous solutions
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
53. Ophthalmoscope: 01
Consist of concave mirror with a hole in centre
Matron ophthalmoscope three mirror 2 concave mirror 1 large and other is
small Plane mirror for retinoscopy
Three mirror attached that central hole come in same place
Series of lenses
Series of hole arranged to measure diameter of pupil
Source light of light on back side
Battery operated well illuminated instrument to study the retinal details
54. SCHEMATIC EYE: 01
Retina pattern should have accurate colour rendition with the physical
dimension matching focal length ratio Ametropia
(-5.00D to + 4.00D)
It should give flexibility to put any power on it to train, including the
cylinder lens
Must be equipped with at least 3 Levels of difficulty with change in the
pupil size (3,5,7 mm) switchable by simulation of small, general and
mydriatic pupil
Should have place for reflection lenses or setting of different degrees
of astigmatism and axial cylinder Must have the Degree of
astigmatism axial angle disk is 0-180
Flexible stand with height adjustment should be included in the model.An ISO
9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
Colourful model of eye which can be studied in layers and assembled
55. PHACOSCOPE: 01
Consist of triangular box the base of which is about 35cm long and
other two sides of 18cm each Height of the box is about 10cm
Painted black inside Mounted on stand
Three angles of box are truncated and provided with holes of
adequate size.
The truncation leave a distance of about 10cm between the apex and
the centre of the base.
At one of truncated angle two prism are placed.An ISO
9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
56. PERIMETER (Lister Type): Automatically records field to 90 degree in all 01
meridians. The Carrier mechanism is smooth, silent and invisible. The patient
9
perceives only the test object to move. Spring check, giving an Audible click to
each 15 degree of rotation of the arc in either direction Renders close scrutiny
of dial plate unnecessary, and ensures accurate registration. The device can
be thrown out of action if silent movement is desired
The marker a needle is housed in a retractable tube, sprung to Sheath
the pint when not actually marking. A set of interchangeable and permanent
washable test objects is included with the instrument. The objects subtend
angles of 4 degree, 2 degree, 1 degree, ½degre, ¼ degree and are in white,
green and red blue objects in the last three sizes are also included. Supplies
complete with Transformer to work on 220 Volt A/C mains With 100 charts. To
be able to record upto 90 degree in all meridians automatically, the patient
perceives the test object moving, with permanent washable test objects in
white, green and red blue colours.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
57. COLOUR PERCEPTION LANTERN EDRIDGE GREEN: To test Colour Vision 01
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
58. Maddox rod: 01
for screen test; Maddox rod lens; red/white/green rim and amp; handle
material: copper handle; length: 70mm,
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
59. NEWTON'S COLOUR DISC/Wheel: On heavy base. On stand rotating 01
handle.
Did you know that there is actually no such thing as white-colored light? The
light that we all perceive as white is actually a mixture of many colors. When
white light splits into a rainbow, for example, we can see seven of its
component colors clearly. This project demonstrates how mixing the light from
these seven colors produces the appearance of white light.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
60. Tuning forks to test hearing 32-10,000 cps (sets) (sets-100,256,512 hz) 10 each
Type:- Hearing test
Shape:- U Shape,
Handle:- Solid,
Length:- 5-7 Inch
Features:- Heavy duty
Material:- Stainless steel and aluminium
Frequency:- 100-200 to 500-600 Hz,
Frequency (Hz):- 288,256,128 HZ,
Surface Finish:- Galvanized
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
61. GRIP DYNAMOMETER: ACCURACY - Equipped with high precision strain 01
gauge sensor, the hand dynamometer gives you accurate momentary digital
reading of gripping power. Measuring Capacity: 198lbs / 90kgs; Division:
0.2lbs / 0.1kgs
USER FRIENDLY - Squeeze the hand dynamometer with maximum isometric
effort for at least 5 seconds. After testing, the LCD will automatically display
the maximum grip value and a grip value status bar showing the status of
“weak”, “normal” or “strong” according to age and gender preset for each test.
MEMORY RECORD - The device can store data for up to 19 definable users,
and their records can be recalled anytime when needed; Moreover, the
incremental increase or decrease from the last record will be automatically
shown for comparison after each test.
Adjustability - Turn the adjustable gear to get an ideal grasp according to the
size of hands. It is good fit for both big hand and small hand.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
62. Otoscope: 01
Should be a C-Cell type or D-cell type Otoscope suitable for usage in
Govt. Hospitals.
10
Should be provided with a halogen/LED light source. (In case of
halogen light source, 2 Nos of spare bulbs are to be provided along
with machine)
Should be able to detach the otoscope head.
Should provide no reflections and obstructions.
Should provide the following detachable accessories: Specula (2.5mm
to 5mm, 4 sizes)
Should have in built rechargeable battery. Recharge should be
possible with direct mains supply
Should be USFDA/ European CE with notified body/BIS approved
product with ISO 13485 certification for quality standards
63. Sterilizer Electric (Medium Size): 01
Construction of stainless steel. For team sterilization/disinfection of surgical
materials/instruments. With handles for lid and base.
Available in various sizes, custom sizes can be made on request.
300X150X100mm
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
64. Instruments Trolley: 01
Framework Made of 18 Gauze of Stainless-Steel tubes mounted on 7.5 cms
castors.Two Platform S.S. Shelves made up of 18 Gauze Stainless steel
sheets with three side railing SS Railing on both shelves.with two shelves.
silent castors with the availability of two brake in the castors.
A SS rectangular frame mounted below the platform sheets to give the high
load-bearing capacity and finish.Complete Non sharpening edge in the trolley.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
Stainless steel frame work of Stainless tubes mounted on four 50mm
diameterswivelling castors. There are two stainless steel shelves with three
side railings on top shelf only in these instrument trolleys. Pre treated and
epoxy powder coated. Overall approximate size : 680mm (L)X450mm
(W)X820mm (H)
65. Stop Watch (Digital): 15
Stop watches reading at 1/5 second with LED/LCD display reading at 1/5
display
66. Physiograph, 3 channels, complete with accessories: 02
(desirable)
Should be able to record three channels with time and event channels.
Transducers should have 16-bit resolution.
Sampling rate should be 250, 500, 1000 samples / second.
Should have plug & play Smart transducers for human applications
including Pulse, Biopotential (ECG / EMG / EEG / EOG), Respiratory
Belt, Cardio Microphone, Tendon hammer, Sphygmomanometer,
Hand grip and Skin temperature.
Software should measure time interval between user selected points,
display of data value at user selected point and tabulate for analysis.
The system should have contents with step by step instructions,
protocol and experimental design for performing various experiments
in physiology applications.
Should have sample data for human and animal experiments for
demonstrating to the students.
Software should support competency-based learning and offer
students to work in small groups and submit / save their work as PDF
or printed report format.
The software should allow educators to customise / modify the
experiments as required.
It should have the option of taking assessments including multiple
choice questions, theoretical questions, drag and drops, Picture
annotation of the students and automated grading facility should be
available.
Software updates and upgrades should be provided for 5 years.
11
Compatible laptop should be supplied.
Certification & Documentation: ISO / CE / IEC / BIS should be
provided
67. Student Physiograph, single channel: 04
(desirable)
Should be able to record single channel with time and event channels.
Transducers should have 16-bit resolution.
Sampling rate should be 250, 500, 1000 samples / second.
Should have plug & play Smart transducers for human applications
including Pulse, Biopotential (ECG / EMG / EEG / EOG) and
Respiratory Belt.
Software should measure time interval between user selected points,
display of data value at user selected point and tabulate for analysis.
The system should have contents with step by step instructions,
protocol and experimental design for performing various experiments
in physiology applications.
Should have sample data for human and animal experiments for
demonstrating to the students.
Software should support competency-based learning and offer
students to work in small groups and submit / save their work as PDF
or printed report format.
The software should allow educators to customise / modify the
experiments as required.
It should have the option of taking assessments including multiple
choice questions, theoretical questions, drag and drops, Picture
annotation of the students and automated grading facility should be
available.
Software updates and upgrades should be provided for 5 years.
Compatible laptop should be supplied.
Certification & Documentation: ISO and CE / IEC / BIS should be
provided
68. Centrifuge High speed with tachometer: 01
CENTRIFUGE RECTANGULAR (Research)
Laboratory Centrifuge are suitable for routine sample analysis in Medical
Hospital, Pathology and Institutional Laboratories .With a wide Choice of rotor
heads and adaptors, these units are truly versatile.
Salient Features:
Digital Speed Indicator
Stepless speed regulator
0-99 minutes digital countdown timer
Imbalance detector with cut off
Safety Lid interlock to prevent cover opening during centrifugation
Press Switch for quick acceleration to full speed.
Technical Data
Control :-Microprocessor
Max.Speed :- 5250
Max.RCF:-3950xg
Motor:- Universal Motor
Display:- Digital LCD with Set & Working parameters
Timer :- 1-99 Min
Capacity
a). 8x15ml tubes.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
69. PHOTOELECTRIC COLORIMETER (DIGITAL): 8 filters Mains operated, 01
sample size 1 ml with 2 ½ digit LED display..
Wavelength Range:- 400-700 nm
Mobility:- Benchtop
Std Glass Filters:- 8 Filters
Display:- 2½ digits LED
Detector:- Hermetically Sealed Photodiode
12
Photometric Resolution:- 1% T & 0.01 in Abs upto 1.99 Abs (O.D.)
Sample Volume:- 1 ml
Power:- 230V +/-10%, 50 Hz
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
70. Digital pH Meter: With temperature compensation and combination pH 01
electrode. 3½ digit LED display for pH measurements.
pH meters of wide: PH meters
• Digital pH meter
• Digital with LCD display
• PH Range from 4-14
• Replaceable electrode
• Resolution 0.1
• Accuracy+0.01
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
71. Porcelain Blood Grouping tiles Special: Porcelain tiles with shallow 40
depressions, approximately 2 inches by 4 inches
72. Oxygen cylinder with trolley 01 (desirable)
Make : Standard
73. Co2 Cylinder with trolley 01
Make :Standard (desirable)
74. Electronic stimulator (Student): 01
Channel: Dual, isolated between channels.
Pulse intensity: Adjustable 0-80 mA peak into 500 Ω load each channel,
constant current
Pulse Rate: 1Hz-160 Hz (adjustable), 1Hz/step (1-20 Hz), 5Hz/step (20-160
Hz)
Pulse Width: 50 µs – 260 µs (adjustable), 10 µs / step
Patient Compliance meter: Shows the treatment times in hours.
Timer: 15, 30, 60 minutes and continuous mode
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
75. WATER DISTILLATION STEEL WITH SPARE HEATING ELEMENTS: 01
(Manasty type) Stainless steel
Manesty type water still: made of all stainless steel; output 4 Lt./hr approx.;
work on 220VAC; the condenser can be opened easily for periodic cleaning.,
designed to provide pyrogen free distilled water easily. Complete unit made of
stainless steel. The lid perfectly rest and get sealed inside the collar on the
head of the tank which avoids loss of steam and jumping of lid., easy wall
mounting.
Output Capacity (Approx.)
a) Output approx. 3/4 litres per hour.
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
76. ALL GLASS DISTILLATION SETS: Incorporating entrapment for making 01
water for injection complete with heater embedding Glass tube .Complete with
metallic stand plug and board etc.
All glass distillation apparatus double stage Flask cap.
Borosil Flask cap. 5ltr.Cap
(a) Double Stage
Auto cut off device
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
77. Voltage stabilizer (5KVA) 01
78 Thermometers, 02
79 Balances, Dispensing balance 100 gm with weight 01
80 Micro-glass slides 25,000
81
82 Digital Physiograph 01
The System should include hardware and transducers for recording
Pulse, Respiration, Blood pressure, Heart sounds, Grip force, ECG,
13
EMG, EEG, Reflex & Reaction time, Forearm Plethysmograph,
wireless HR etc.
ECG Multi leads configurations for real time cardiac axis & vector
analysis (to derive Lead III, aVl, aVf,aVr).
System should be suitable to perform Nerve Conduction Velocity,
Pulse Transit Time and Visual Evoked Potential (VEP).
System should have spirometer to record lung function test (Tidal
Volume, Minute Ventilation, Respiratory rate, PIF, PEF, FVC, FEV1
etc.).
Should have transducers to perform AFT procedures like deep
breathing test, Valsalva manoeuvre, HRV and Hand Grip test.
Data recording should have minimum 4 channels with high speed USB
integration and analog output for stimulation or pulse generation.
Should have wide range of low Pass, high-pass, notch, mains filter
and software based digital filters (low pass, high pass, band pass etc.)
Universal Bio-Amplifier – at least 2 Channels in built with range of
±100μV to ±20mV.
Human safe Isolated Stimulator - should be able to deliver user
defined waveforms with pulse duration of 1-1000 mS and output
current 0 - 20 mA.
All-in-one software to record and analyse the above mentioned
parameters both online and offline.
Software should perform On-line & Off-line analysis of ECG and HRV
as follows.
HRV analysis – Time & Frequency domains, Tachogram,
Histogram plot, Poincare plot, Power Spectrum plot etc.
ECG analysis – Averaging, PQRST amplitudes and intervals,
QT vs RR, QT vs Time, RR vs Time, Waterfall plot, ST
elevation and cardiac axis analysis
Software should allow the export of raw data in .txt, .mat, .wav, .abf,
.pxp, binary and .edf, formats.
Software should have option for video recording synchronized with the
data.
Software should allow OLE linking of data to MS Excel
Power input to be 220-240VAC, 50Hz.
The system should be supplied with latest computer with Windows10
OS, i5 Processer, 8 GB RAM, 21” monitor and 1 KVA UPS with
required accessories
Documentations ISO and CE/FDA, and other safety certificates must
be provided
Company should have local offices in India for on time support and
service
Demonstration and training at site.
83 Charts 20
Model 20
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
84 Amphibian Lab (CAL Lab for amphibian experiment) 1
The software program should be a user-friendly interactive desktop
application, capable of running several applications simultaneously within one
program including: data collection, background materials, data analyses, and
reporting options.
The software should have interactive experiments including content,
procedure, literature, videos etc.
It should allow students to save their laboratory progress and PDF report
of their data.
Human Physiology, Airflow, Autonomic Nervous System (ANS), Blood
Clotting, Blood Counting, Blood Pressure, Body Temperature, Breathing,
Cardiorespiratory Effects of Exercise, Cardiovascular Effects of Exercise,
14
Diving Response, Electroencephalography (EEG), Electro-oculography
(EOG), Energy Expenditure & Exercise, Glucose Absorption Heart & ECG,
Heart & Peripheral Circulation, Heart Sound, Kidney & Urine, Lung
Volumes Mechanics of Ventilation, Muscle & EMG, Peripheral Nerve
Function, Reflexes and Reaction Times, Sensory Illusions, Sensory
Physiology, Skeletal Muscle Function Spinal Reflexes, Stroop Test, Water
Balance.
Animal Physiology Animal Metabolism, Frog Heart, Frog Nerve, Frog
Neuromuscular Junction, Frog Skeletal Muscle, Gin Trap Closure Reflex,
Intracellular Action Potentials.
In Vitro experiments - Guinea Pig ileum experiment Dose Response
Curve, Guinea Pig Trachea Experiments-Physiological antagonism,
Experiments on the isolated, perfused mammalian heart.
In Vivo experiments -Effect of Drugs on Blood Pressure - Dog Blood
Pressure, Effect of Miotics and Mydriatics on Rabbit Eye , Study the
effects of several pharmacological agents on rat blood Pressure
Other experiments Pharmacology Airways Resistance and Vascular
Resistance Mammalian Atria, Heart, Jejunum, Uterus Stimulated Ileum,
Rat Vas Deferens Unstimulated Ileum, Rat Vas Deferens. Rota Rod
Experiments to test Sedative agents. Cooke's climbing experiment to
differentiate between sedative agents and anti-psychotic drugs Analgesic
Drugs - Using Hot Plate, Using Tail Flick Test and Writhing Test, Anti-
Inflammatory Drugs – Using Carrageenan Rat Paw Edema Model, Local
Anesthetics – Rabbit Corneal Reflex, Guinea pig- Infiltration anesthesia,
Frog withdrawal Reflex
Compatible Computer with 19-inch LED monitor, to be provided with
system.
Lifetime license cost for offline model and subscription cost (5 years) can
be provided separately. The software must have a facility to edit and
customize lesion and create their own experiments as per the lecturer
choice for at-least warranty terms.
The system should be upgradable to online cloud-based system in future
so that the student can access the data from any-where using internet
facility.
Instrument- Four channeldata acquisition system for Human & Animal
Physiology Experiments for Biophysical Parameters interfaced with above
cited software for better hands-on training to students.
Mandatory demonstration and training.
Necessary certificate for safe use for human.
Hardware:
Supply and installation of Server with Monitor, keyboard, Mouse & 1 kva
UPS with 1 hour backup: 1 no.
Supply and installation of Thin Clients with Monitor, keyboard, Mouse&
UPS: 50 nos.
Networking
Webcam: 1080 Full HD quality video with omnidirectional mics: 1
Suitable curtains for doors and vertical blinds for windows.
85 ECG Machine Single channel: 02
Number Of Channels:- 1 Channel
Machine Type:- Digital
Recording Speed:- 5mm/s
Digital Display:- Yes
15
Operating Mode:- Automatic
Filters Type:- Emg Filter
Enduring polarization voltage:- 220V
Frequency:- 50Hz
Features
Ample clear ECG tracings.
Automatic & Manual Operating modes.
Auto & Manual Parameter Calculations.
12 Lead Simultaneous Acquisition.
Feather touch membrane keypad operation.
Parameters Display on backlit LCD.
In built rechargeable battery with charger.
Compact light weight portable easy to use.
Maintenance free thermal array printer.
USB connectivity for computer
Copy Facility
One button operation
ECG measurements
An ISO 9001:2015/13485:2016/GMP/OHSAS
18001:2007/CE/NSIC/MSME/BIFMA certified Co
86 Snellen’s Drum for Visual 5
Acuity: for visual acuity – a metallic cuboidal drum with different symbols,
alphabets and number on 4 surfaces, which can be
rotated and with a bulb/light source inside it
for visual acuity – a metallic cuboidal drum with different symbols, alphabets
and number on 4 surfaces, which can be rotated and with a bulb/light source
inside it
87 Ishihara Charts: A small book with plates containing different colour 5
pattern with both numbers and pathways for identification and tracing supplied
with the manual
88 Metronome: For generating beats from 1-10 per sec 10
89 Jaeger’s Chart: A small book with plates containing different colour pattern 5
with both numbers and pathways for identification and tracing supplied with the
manual
A chart with different sentences written in different fonts to
test near vision
16