6LHPHQV5HPRWH6HUYLFHV
&2
+DUGZDUH,QVWDOODWLRQ*XLGH
5',$*5RXWHU$QDORJ,36(&
3DUWQXPEHU
© Siemens AG 2002
The reproduction, transmission or
use of this document or its contents
is not permitted without express
written authority. Offenders will be
liable for damages. All rights,
including rights created by patent
grant or registration of a utility model
orr_ design,,_aree_ reserved.
Print No.: COIT-000.812.04.02.02 English
Replaces: COIT-000.812.04.01.02
Doc. Gen. Date: 01-02
Installation instruction
5HYLVLRQKLVWRU\
&KDSWHU 3DJHV 5HYLVLRQ
all all 01
all all 02
Siemens Remote Service COIT-000.812.04.02.02 Seite 2/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
813$&.7+(%2;
%()25(,167$//$7,21
&211(&7,1*32:(5$1'7851,1*7+(5287(521
&211(&7,1*&,6&2727+(/$1
&211(&7,1*&,6&2 :,& 727+(:$1
),1$/&21),*85$7,21±3(5)250('%<6,(0(165(027(6(59,&(
$33(1',;
Siemens Remote Service COIT-000.812.04.02.02 Seite 3/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
8QSDFNWKH%R[
%HIRUH,QVWDOODWLRQ
Cisco 1600 series routers are shipped to you ready for desktop mounting. Before connecting the
router to the network and power supply, simply set the router on a desktop, shelf, or other flat surface.
The router you got is preconfigured by SIEMENS Medical Solutions. The router package includes
power cords for the US and Europe. You need to provide a power cord for other countries. Pay
attention to the Maximum Cable Lengths (see Appendix C).
Siemens Remote Service COIT-000.812.04.02.02 Seite 4/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
&RQQHFWLQJ3RZHUDQG7XUQLQJWKH5RXWHU2Q
You can verify your installation by checking the appropriate LEDs during the installation process if you
switch the router on before making any network connections.
Follow these steps to connect the router to the power supply and turn it on:
6WHS Connect the DC power cable (included with the router) from the power supply to the DC power
input on the rear panel of the router. (Figure 1)
6WHS Connect the female end of the cable to the male receptacle of the power supply.
6WHS Connect the male end of the power cable to the power outlet.
6WHS On the rear panel of the router, turn the power ON by setting the switch labeled I / O to the I
position.
6WHS Slip the wire clip over the power cord to ensure that the power cord remains attached to the
router, as shown in Figure 1.
6WHS Check the following LEDs:
• The SYSTEM PWR LED (front panel)---On if power is being supplied to
router.
• The SYSTEM OK LED (front panel)---On while router software is
operational. (This LED first blinks and then remains on continuously.)
• The OK LED (rear panel, next to Flash PC card slot)---On if the Flash
memory card is installed correctly.
)LJXUH
Siemens Remote Service COIT-000.812.04.02.02 Seite 5/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
&RQQHFWLQJ&LVFRWRWKH/$1
One of the gray straight-through RJ-45-to-RJ-45 cables (contained in the package – do not use a
cable with the label „CAB-U-RJ45“) is necessary for this connection. Follow these steps to connect the
router to a 10BaseT Ethernet LAN (Figure 2):
6WHS Connect one end of the Ethernet cable to the 10BASE T port.
6WHS Connect the other end of the cable to one of the ports on the 10BaseT hub, switch or network
walljack.
6WHS Check the following LEDs:
• LNK LED (rear panel, next to 10BaseT port)---On if the router is connected
correctly to the 10BaseT Ethernet LAN.
• LAN ACT LED (front panel)---On while there is traffic on the Ethernet LAN.
)LJXUH
1RWH If you want to connect the router directly to a PC, Server, Workstation you will need a cross
over RJ-45-to-RJ-45 cable (QRWLQFOXGHGLQWKHSDFNDJH .
Siemens Remote Service COIT-000.812.04.02.02 Seite 6/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
&RQQHFWLQJ&LVFR :,& WRWKH:$1
The 1-port serial WAN interface card (see Figure 3 – already built in the router) has a DB-60 serial
port. Use the correct cable (contained in the package) for your serial WAN interface card (CAB-
232MT).
6WHS Use the serial cable and connect one end of the cable to the serial port of the router (Figure 3)
6WHS Connect the other end of the cable to the asynchronous modem that you provide (Figure 4)
6WHS Connect the modem to the telephone line
In case the modem you want to use was formerly connected directly to a system/modality, the modem
needs to be reset to factory defaults before it can be used. For Multitech modems, this procedure is
described in $SSHQL[-, for other modems, refer to their instruction guide.
)LJXUH
)LJXUH
Siemens Remote Service COIT-000.812.04.02.02 Seite 7/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
)LQDO&RQILJXUDWLRQ±SHUIRUPHGE\6,(0(16
5HPRWH6HUYLFH
The router hardware configuration is finished. The final configuration will be carried out by SIEMENS
Remote Services. This service is free-of-charge. '2127 start to configure the router by yourself
In order to use the central service of remote final configuration, fill out the checklist which can be found
either in the router box or in the internet at the following address:
http://www-td.med.siemens.de/router/checklist.doc
,WLVLPSRUWDQWWKDW\RXGRQRWXQGHUWDNHDQ\DGGLWLRQDOFRQILJXUDWLRQVRQ\RXURZQVLQFHWKH
FRQILJXUDWLRQQHHGVWRFRPSO\ZLWKFHUWDLQVWDQGDUGVLQRUGHUIRUWKHURXWHUWRIXQFWLRQ
SURSHUO\
The final configuration includes registering the medical systems by the remote diagnostic server at
SIEMENS Remote Services.
Siemens Remote Service COIT-000.812.04.02.02 Seite 8/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
$SSHQGL[
$SSHQGL[$ )URQW3DQHO/('V
/(' &RORU 'HVFULSWLRQ
SYSTEM PWR Green The router is turned on, and DC power is being supplied.
SYSTEM OK Green The router has successfully booted. Blinks during the boot cycle.
LAN ACT Green Data is being sent to or received from the local Ethernet LAN.
LAN COL Yellow Flashing indicates packet collisions on the local Ethernet LAN.
An ISDN connection on B-channel 1.Cisco 1604 only---If an ISDN device
BRI 0 B1 Green
connected to the ISDN S/T port is using B-channel 1, the LED turns on.
An ISDN connection on B-channel 2.Cisco 1604 only---If an ISDN device
BRI 0 B2 Green
connected to the ISDN S/T port is using B-channel 2, the LED turns on.
WIC CD Green Active connection on the WAN interface card serial port.
WIC ACT Green Data is being sent over the WAN interface card serial port.
$SSHQGL[% 5HDU3DQHO/('V
/(' &RORU 'HVFULSWLRQ
LNK(next to Indicates 10BaseT link integrity. This LED is not on when connected to an
ETHERNETØ Green Ethernet network through the AUI port. The Cisco 1605 has two LNK
10BASET) LEDs, one for each Ethernet 10BaseT port.
OK (next to
FLASH PC Green The Flash PC card is correctly installed.
CARD slot)
OK (next to
A physical connection has been established with the ISDN central office
ISDN BRIØ Green
switch.
S/T port)
$SSHQGL[& 0D[LPXP&DEOH/HQJWKV
&DEOH 0D[LPXP/HQJWK
Ethernet 100 metres
ISDN S/T 10 metres
Telephone cable 152 metres
$SSHQGL[' 5HFRPPHQGHG0RGHP
&RXQWU\ 0RGHP7\S 6,(0(163DUW
Germany Multitech MT2834ZDXIe-33-DE 5533356
Japan Multitech MT 2834 ZDXI-33-JP 5533364
Switzerland Multitech MT2834ZDXIe-33-CH 5533372
Sweden Multitech MT2834ZDXIe-33-SE 5533380
Norway Multitech MT2834ZDXIe-33-NO 5533398
Netherlands Multitech MT2834ZDXIe-33-NL 5533406
Italy Multitech MT2834ZDXIe-33-IT 5533414
Belgium Multitech MT2834ZDXIe-33-BE 5533422
United Kingdom Multitech MT2834ZDXIe-33-GB 5533430
USA/Canada Multitech MT2834ZDXB-SC 5533463
France Multitech MT2834ZDXIe-33-FR 5533448
Austria Multitech MT2834ZDXIe-33-AT 5533455
Other Multitech MT2834ZDX+ country specific adapter obtain modem locally
Siemens Remote Service COIT-000.812.04.02.02 Seite 9/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
$SSHQGL[( &RQQHFWLQJWKH&RQVROH3RUW
The cable and adapters required for this connection are included in the package. Follow these steps to
connect the router to a terminal or PC:
6WHS Connect one end of the light-blue console cable to the light-blue CONSOLE port of the router
(Figure 5).
6WHS Use the correct adapter to connect the other end of the cable to your terminal or PC (serial
interface).
1RWH If your terminal or PC has a console port that does not match any of the adapters, you must
provide the correct adapter for that port.
)LJXUH
$SSHQGL[) 3DVVZRUGV
The enable password – used to get into the enable modus of the router – is SUHVHF.
$SSHQGL[* &RQILJXUH3& HJ+\SHUWHUPLQDO IRUFRPPXQLFDWLRQ
Once your router is correctly connected to your PC, you can start building your configuration. The
Windows Hyperterminal emulation is the interface to your Cisco 1603 router.
6WHS Start Hyperterminal from the „Programs – Accessories – Hyperterminal“ menu in the start
panel. If you do not find the program there or anywhere else on your computer, you will have
to install it first.
6WHS In the „Connection Description“ dialogue box
• enter a name for the connection and choose an icon. If you want to save the connection
settings click „ok“
• RU click „Cancel“
Siemens Remote Service COIT-000.812.04.02.02 Seite 10/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
Siemens Remote Service COIT-000.812.04.02.02 Seite 11/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
6WHS Choose „Properties“ from the „File“ menu. On the „Connect to“ tab, check, if the port (e. g.
COM1) to which your router is connected is selected.
6WHS Click „Configure“ and make sure that the settings have the following values: Bits per second:
9600, Data bits: 8, Stop bits: 1, Flow control: Hardware. Click „OK“ twice to leave
configuration mode.
6WHS Choose „Connect“ from the „Call“ menu to establish a connection to the router.
Siemens Remote Service COIT-000.812.04.02.02 Seite 12/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
$SSHQL[- &RQFHUQLQJPRGHPVIRUPHUO\GLUHFWO\FRQQHFWHGWRV\VWHPV
In case you ordered a new analog SRS router (Cisco 805 or Cisco 1603 Analog), and the router is
supposed to be connected to a modem which was formerly connected directly to a system/modality, it
is absolutely necessary to reset the modem to factory defaults. Otherwise the modem cannot be used
along with a SRS router.
The procedure to configure the modem via the router is called ‚reverse telnet‘. In order to carry out this
procedure, please follow the steps below. This is RQO\ the procedure for 0XOWLWHFK Modems. If you
have a different type of modem, you will have to consult the instruction manual in order to reset the
modem to factory defaults.
6WHS Connect the light blue console cable to the router and to the 9 pin serial connector on the PC.
[Refer to $SSHQGL[(in the HW installation guide.]
6WHS Ensure that the router is connected to Ethernet.
6WHS Start Hyperterminal (click Start – Programs – Accessories – Hyperterminal – Hyperterminal).
[Refer to $SSHQGL[in the HW installation guide.]
6WHS Enter a name for this connection and click „OK“.
6WHS In the drop-down-box choose the COM port the console cable is connected to.
6WHS In the properties dialogue box click „OK“.
6WHS Hit ‚Enter‘ until you see the router prompt, e. g. jac0356323qc828>
You have now established a connection to the router and will enter the following commands on the
router itself:
Siemens Remote Service COIT-000.812.04.02.02 Seite 13/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions
Installation instruction
GHVFULSWLRQ 5RXWHUSURPSW FRPPDQG
6WHS Enter into the enable modus of jac0356323qc828> HQDEOH
the router
6WHS Enter the password to get into password: SUHVHF
the enable modus (this entry is
not visible)
6WHS Enter into the configuration jac0356323qc828# FRQILJXUHWHUPLQDO
modus of the router
The following output will appear Enter configuration
commands, one per line.
End with CNTL/Z.
6WHS set the ip for modem1 jac0356323qc828(config)# LSKRVWPRGHP
6WHS Enter ctrl-z jac0356323qc828(config)# A]
The following output will appear 3d22h: %SYS-5-CONFIG_I:
Configured from console
by console
6WHS log onto the modem jac0356323qc828# PRGHP
The following output will appear Trying modem1
(10.6.254.2, 2001)...
Open
User Access Verification
6WHS Enter the username username SUHUGLDJ
6WHS Enter the password (not visible) password SUHVHW
The following output will appear Password OK
6WHS Echo on DWH
The following output will appear OK
6WHS Reset to factory settings. DW I Z
1RWH: 0 is „zero“
The following output will appear OK
6WHS Press ctrl-shift-6 A>VKLIW@
6WHS [
6WHS Disconnect from the modem jac0356323qc828# GLVFRQQHFW
6WHS Confirm that the connection to Closing connection to FU!
modem1 shall be closed modem1 [confirm]
6WHS H[LW
Now your modem and your router are ready to be remotely configured by SIEMENS Remote Services.
$SSHQGL[. ,6'1XVHRIWKHDQDORJURXWHU
1RWH Should it become necessary to switch from the analog connection to an ISDN connection, the
configuration can be done via the analog port of the router.
Siemens Remote Service COIT-000.812.04.02.02 Seite 14/14 Siemens AG
Rev. 02 02-02 CO SGK Medical Solutions