Product Range

_ Reliable measurements
_ Quality components
_ Low energy consumption
_ Easy data retrieval

OTT ground water measurement


Practical measuring devices
OT T Orpheus Mini OT T CTD
Ground Water Data Logger Ground Water Data Logger
with conductivity measuring cell
RS RS
4 GP om 4 GP om
-C -C
4 IP 4 IP

Features / Benefits The OTT Orpheus Mini is designed primarily for use in observation Features / Benefits For monitoring conductivity, the OTT CTD has the right solution.
_ Capacitive ceramic pressure wells or wellhead shafts, but also provides reliable data in numer­ _ For environmental checks in Thanks to the integrated conductivity measuring cell, it not only
cell – robust, precise and with ous level measurement sites in surface waters. Due to its quality ground and surface water measures the water level and temperature, but also provides
long-term stability components, it is particularly tough and long-lived. _ Corrosion and salt-water indicator values for the presence of potential pollutants.
_ Quality, salt-water resistant, resistant housing material
stainless steel housing A pressure probe measures the hydrostatic pressure of the water _ 4-electrode conductivity The voltage drop in the flowing water is measured with the
_ Low energy requirements column above the measuring cell and uses this to determine the measuring cell conductivity measuring cell. From voltage drop, current strength
_ Fast battery change without water level. In the process it compensates for influences from _ Convenient software for all and temperature, a microprocessor calculates the value for the
tools – the probe remains in temperature or air pressure variations – the integrated temperature important operating steps specific conductivity. From this it infers the salinity and the total
the water sensor and the pressure compensation capillary in the probe cable _ Can be equipped for remote dissolved solids (TDS).
_ Easy installation – adapter provide the necessary conditions. transfer with OTT ITC without
plates for wells from 1“ additional wiring From the capacitive ceramic pressure cell to the quality stainless-
_Remote transfer via GSM/SMS/ The measurement data are automatically saved in the integrated _S  imple installation in obser­ steel housing – all components of the OTT CTD are designed to
GPRS with OTT ITC datalogger. They can be transferred via the infrared interface to a vation wells from 1“ also resist adverse environmental conditions.
laptop or Pocket PC. The convenient operating program assists
the process. Remote transfer via SMS, GMS or GPRS/IP-Com is Reading out data and parameterization on-site is convenient via
also easy to implement with the OTT ITC top cap. the infrared interface. And with the help of the OTT ITC top cap,
the CTD can quickly be equipped for remote data transfer. That
can also be done after installation and requires no additional
wiring.

Technical Data Technical Data


Quantitative Hydrology

Measuring ranges, 0 ... 4 m, 0 … 10 m, 0 … 20 m, Measuring range/Accuracy


pressure 0 … 40 m, 0…100 m water column GSM pressure and temperature see Orpheus Mini
Accuracy, pressure 0.05 % FS GPRS/IP Measuring range, 0.001 ... 2.000 mS/cm
Longterm stability ± 0.1% / year FS conductivity 0.10 ...100.00 mS/cm
Measuring range, temp. - 25 °C … +70 °C (ice-free) Accuracy, conductivity ± 0,5 % FS
Accuracy, temperature ± 0.5 °C; optional ± 0.1 °C ±1,5 % FS
Power supply 3 x 1.5 V LR6/FR6-cells, Alkaline or Power supply/Lifetime see Orpheus Mini
Lithium type IrDA Memory 4 MB (approx. 500,000 measur. values)
Lifetime ≥ 5 years (Lithium); Sample/Storage interval 5 seconds … 24 hours
> 1.5 years (Alkaline) Interface Infrared (IrDA)
Memory 4 MB (approx. 500,000 measur. values) Material of casing ABS, stainless steel (DIN 1.4539, 904 L)
Sample / Storage interval 1 second … 24 hours
OTT ITC – for quickly implementing Interface Infrared (IrDA)
remote transfer of groundwater data Material of casing ABS, stainless steel (DIN 1.4539, 904 L) Remote data transfer with OTT ITC
OT T Thalimedes OT T KL 010
Shaft Encoder with Data Logger Contact Gauge

Features / Benefits The float-operated OTT Thalimedes is suitable for continuous water Features / Benefits The OTT KL 010 Contact Gauge is perfectly designed for
_ Can be used flexibly: in obser- level measurement both in ground and surface water. Installed in _M  obile measurement in well- depth calculation in the field. Indestructible, lightweight and
vation wells from 4“, in float float shafts or observation wells from 4“, it provides low-cost, re- head shafts, observation wells, simple to operate it is built to give years of accurate check
shafts or as an upgrade for liable measurements. Also in combination with existing recorders, tanks, boreholes and with measurements.
mechanical level recorders it makes the output of digital data possible with little effort. pump tests
_ Compact design _ For depths up to 750 meters The probe is let down with a hand crank, e.g. into an observa-
_ Low energy consumption – up The float pulley moves via a float-cable counterweight system _ Impact-resistant, light drum tion well or borehole. As soon as it touches the water surface,
to 15-month operation with with even the smallest changes in water level. The position of the _ Stable measuring tape a signal sounds and the signal lamp lights up: The distance
only one 1.5 V C-type cell float pulley is converted to an electronic signal and saved in the _ Easily read division into m, dm between water surface and reference level can now be read
_ Simple operation integrated data logger, at intervals you can set. and cm on the measuring tape.
_ Display for reading measure- _ Optional: KL 010 TM with
Additional function: Water temperature
ments and parameters Wireless data transfer is possible to a laptop or Pocket PC with integrated temperature sensor
If the water temperature is needed, the OTT KL 010 TM model
_ Remote data transfer systems the infrared interface. The RS-232 interface allows connection to and display
offers a temperature sensor as well. Letting down the probe
can be connected via RS-232 remote data transfer systems, such as the OTT ITC top cap.
in stages allows the creation of a temperature profile. The
(e.g. OTT ITC)
temperatures measured can be easily read from the integrated
display.

Technical Data Technical Data

Quantitative Hydrology
Measuring range, Measuring tape Polyethylen, white
adjustable ±19.999 m / ±199.99 m / ±199.99 ft Accuracy 0.1 % FS
Maximum measuring error ± 0.002 m / ± 0.002 m / ± 0.0066 ft Tape drum Special plastic, high strength,
Measuring range, temp. - 20 °C … +70 °C resistant to low temperatures
Power supply 1 x 1.5 V C-type cell, Alkaline Frame Cast aluminium, plastic coated
Measured value memory EEPROM (approx. 500,000 measured values) Power supply 4 x 1.5 V C-type cells; Alkaline
Sample / Storage interval 1 minute … 24 hours Lifetime ≥ 12 months
Interfaces RS-232/SDI-12; Infrared (IrDA) Probe body Non rusting steel, nickel-plated
Data logger brass
Material of casing Plastic, IP 68 Measuring range KL 010 15 m … 750 m (12 levels)
Dimensions L x Ø 244 mm x 47 mm Measuring ranges KL 010 TM
Encoder unit Depth 25 m … 500 m ( 8 levels)
OTT Thalimedes combined with the Material: Plastic, IP 54 Mobile measurement with the Temperature -5 °C … + 60 °C
OTT R20 strip chart level recorder Dimensions L x W x H 82 mm x 82 mm x 34 mm OTT KL 010
290 290

280 280

Germany Austria UK & Ireland India Southern Africa 270 270


OTT Hydromet GmbH OTT Hydromet GmbH OTT Hydrometry Ltd. OTT Hydromet OTT SOUTHERN AFRICA (PTY.) Ltd.
Ludwigstrasse 16 Branch office Austria Unit 2 Magnet Business Park c/o DHR Holding India Private Ltd. 97 Bedford Avenue 260 260
87437 Kempten Weidegut 76 14 High Hazels Road, Barlborough 608-609, Rattan Jyoti Building, 1500 Benoni
Tel. +49 831 5617-0 4223 Katsdorf Chesterfield S43 4UZ 18 Rajendra Place, New Delhi 110 008 Tel. +27 11 421 4484250 250

Fax +49 831 5617-209 Tel. +43 7235 8899-8 Tel. +44 1246 573 480 Tel. +91 11 45094 781-112 Fax +27 11 421 4485
[email protected] Fax +43 7235 8899-1 Fax +44 1246 813 873 Fax +91 11 45094 785 [email protected] 240 240

www.ott.com [email protected] [email protected] [email protected] www.ott.com


230 230
www.ott-austria.at www.ott-hydrometry.co.uk www.ott.com/india
220 220

France Switzerland Spain Brazil


OTT France OTT HYDROMETRIE AG OTT MedioAmbiente OTT Hydromet 210 210

Europarc de Pichaury – Bât. D2 Obere Bahnhofstrasse 13 C/Teide, nº 5 - Planta Baja, Local nº 2 Av. Major Sylvio de Magalhães Padilha, 5200
200 200
13799 Aix en Provence Cedex 3 5507 Mellingen Parque Empresarial La Marina Ed. Philadélphia, Boco B, Cj. 42
Tél. +33 (0)4 42 90 05 90 Tel. +41 56 470 64 34 28700 San Sebastián de los Reyes (Madrid) CEP: 05693-000, São Paulo, SP 190 190
Fax +33 (0)4 42 90 05 95 Fax +41 56 491 21 06 Tel. +34 91 651 47 69 Tel. +55 11 3759 -7632
[email protected] [email protected] Fax +34 91 659 02 09 Fax +55 11 8711- 9476 180 180
www.ottfrance.com www.ott-schweiz.ch [email protected] [email protected]
www.ott-medioambiente.com www.ott.com 170 170

160 160

OTT ground water measurement


150 150

140 140

Practical measuring devices


130 130

120 120

110 110

100 100

90 90

80 80

www.ott.com

02-12/2010
70 70

60 60

50 50

93.000.005.I.E
40 40

30 30

20 20

10 10

0 0

You might also like