PEAK,

INSTRUMENTS

Spectrophotometers
Variety&Reliability

PEAK Instruments Inc.


SP NIN

About Us
PEAK Instruments Inc. is located in Houston,
TX-77084, where our head office and warehouse
are also located, which is a high tech enterprise
integrated with R&D, production, sales and
service of spectrophotometers, which have wide
applications in the following areas: metallurgy,
pharmacy, food, health, institutes, biological
oe

chemistry, life science, petrochemical industry,


quality control, environmental protection, etc..

We adopt the newest microcomputer technology


and electronic control system, optimize optical
system and structure which can both extend new
functions and ensure the accuracy, sensitivity,
stability and durability. We have all kinds of
spectrophotometers like UV, visible, single beam,
double beam, adjustable slit, xenon and big
capacitive touch screen with high resolu-
tion(1024*600) and high sensitivity.

We have professional teams for management,


R&D, production, QC, sales and technical
support, which make sure to provide excellent
products, good prices and efficient service for our
global customers. We have obtained 46 patents
and CE, !S$09001, 1S0O14001 certificates driven
by innovation and joint efforts of all staff.
ep]
TS
fey
a
a
BS i
By, 7
2
<a

pf a
2
aa

Ne
We continuously absorb new ideas, promote product quality and improve our service in accor-
dance with the concept of Innovation, quality and service. We have steady growth and good reputation in the
markets of more than 30 countries, like USA, Canada, Mexico, Spain, Poland, Turkey, Russia, Argentina,
Brazil, Chile, Peru, Ecuador, India, Indonesia, Pakistan, Korea, Saudi Arabia and South Africa.

@ Our Promise
Answer customers and provide solutions within 24 hours.

@ Our Mission
Provide high quality products and services.

@ Our Vision
To be a well-known brand for analytical instruments.

PEAK Instruments Inc. looks forward to cooperating with you.


| ntroduction
Smooth appearan
ce design
ingenious color
+

assortment
* Blue backlit LCD
screen
Oval buttons
*

Easy Parameter se
+

tting and micropro


cessor make the
Operation more co
nvenient

Main Features

* Calibrate o%A and


100%T automaticall
y.
* Large Sample co
mpartment can
hold various Cel
ls from 5mm to
100mm and meet
different test re
quirements.
E-1000 Series

pebaerete La

MODEL E-1000V E-1000UV

Display 70*40mm backlit LCD

Wavelength Range 320 - 1020nm 190 - 1020nm

Slit Width 4nm

Wavelength Accuracy +2nm

Wavelength Repeatability <1nm

Photometric Accuracy 0.5%T

Photometric Repeatability 0.2%T

Stray Light <0.15%T@360nm

Stability 0.002A@500nm

Output Port RS232

Light Source Tungsten Halogen Lamp Tungsten Halogen/Deuterium Lamp

Power Requirements 110-220V, 50-60Hz

Photometric Range 0-200%T, -0.3-3A

Shipping Dimensions And Weight 530*460*320mm, 9 kg


C-7000 Series

hnology and electronic


e des ign . Ado pt the newest microcomputer tec
t appear anc
Steady, modern and elegan and ensure the accuracy,
and str uct ure can bot h extend new functions
optical system
control system. Optimized

stability and durability.

ive silicone buttons.


and lon g life, mor e comfortable and sensit
* 7 inch TFT screen ,” 4xt,*.bmp) . Users
h as Excel, txt and photos(*.csv, * qua
different data formats suc
* Support USB storage and iliary software.
edit the m on co mpu ter s directly without any aux
sh memory, open and
can output test data to fla equipped with RS232, HO
ST
rd 8GB mem ory can store huge test data and
lity: Standa
* Strong extended capabi
USB interface.
USB port and standard
and ultra-low stray light.
cie ncy hol ogr aph ic grating of 1200 lines/mm
* High-e ffi k up to 2000
en- hal oge n and deu ter ium lamps which can wor
ife socket type tungst
* The equipment has Long-l omatically. Socket type
ing to test nee ds and record its working time aut
ps accord
hours, can switch the lam
ement much easier.
lamps make the replac
sensitive and stable.
iod e can gua ran tee the equipment is highly
* Excellent silicon photod
t all kinds of needs.
ple cha mbe r and var ious accessories can mee
« Huge sam
test charts and data.
nter directly and output
* Can be connected to pri
realize scanning function.
» Powerful PC software can
C-7000 Series ©
Specifications
MODEL C-7000V C-7000UV

Display 7-inch TFT screen

Wavelength Range 320 - 1100nm 190 - 1100nm

Slit Width 2nm 2nm

Wavelength Accuracy +0.3nm +0.3nm

Wavelength Repeatability <0.2nm

Photometric Accuracy 0.3%T (0-100%T), +0.002A(0-0.5A), +0.004A(0.5-1A)


Photometric Repeatability <0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)

Stray Light £0.05%T@220 nm, 360nm

Stability +0.002 A/h@500nm

Baseline Flatness +0,002A +0.002A

Noise +0.0005A

Working Mode T,A,C,E

Wavelength Setting Automatic

Photometric Range 0-200%T, -0.3- 3A

Detector Solid Silicon Photodiode

Software Optional with scanning function

Printer Optional

Keypad Silicone Buttons

Data Port USB

Light Source Tungsten Halogen Lamp Tungsten Halogen/Deuterium Lamp

Power Requirements 110-220V, 50-60Hz

Humidity Range Less than 85%

Shipping Dimensions and Weight 770*630*340mm, 27kg


C-7100/7200 Series

y and electronic
. Ado pt the new est microcomputer technolog
gant appearance design
Steady, modern and ele and ensure the accuracy,
tem ard str uct ure can both extend new functions
optical sys
contro} system. Optimized

stability and durability.

w
The instrument can sho
com for tab le and sen sitive silicone buttons.
long life, more
e 7Vinch TFT screen and .
tests without computers
and cha rts for use rs to com plete various
yarious scanning Curves * qua,” txt,” bmp) . Users
el, txt and photos(*.csv,
sto rag e and dif fer ent data formats such as Exc
* Support USB tware.
without any auxiliary sof
, ope n and edit the m on computers directly
h memory
can output test data to flas equipment can store
pro ces sor wit h the clock speed 420MHz. The
and 32-bit Cortex _M3
* Advanced hardware
500 curves.
5000 pieces of data and
ultra-low stray light.
ncy hol ogr aph ic gra tin g of 1200 lines/mm and
* High-efficie which can work up to 200
0
typ e tun gst en- hal oge n and deuterium lamps
g-life socket
° The equipment has Lon tically. Socket type
to test nee ds and rec ord its working time automa
ps according
hours, can switch the lam
ement much easier.
lamos make the replac ie.
is highly sensitive and stab
sili con pho tod iod e can guarantee the equipment
« €xcellent
all kinds of needs.
cha mbe r and var iou s accessories can meet
* Huge sample
.
put test charts and data
printer directly and out
» Can be connected to

° Powerful PC software. RS232, HOST


ory can stor e hug e test data and equipped with
y: Standard BGB mem
« Strong extended capabilit
interface.
USB port and standard USB
~s C-7100/7200 Series @
Specifications
MODEL C-7100 |C-7100S |C-7100A| C-7200 |C-7200S| C-7200PC | C-7200A

Display 7 inch TFT No Screen | 7 inch TFT

Keyboard Control Silicone Buttons No Buttons silicone


Buttons

Single Beam Double Beam


Optical System
Holographic grating, 1200 lines/mm

Slit Width 2nm | 4tnm ae 2 | onm | itnm_ | 2nm, inm ie 2,


Wavelength Range 190 - 1100nm

Wavelength Accuracy +0.3nm

Wavelength Repeatability <0.2nm

Photometric Accuracy 0.2%T (0-100%T), +0.002A(0-0.5A), +0.004A(0.5-1A)


Photometric Repeatability <0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A (0.5-1A)
Stray Light $0.03%T@220nm, 360nm

Stability +0.002A/n@s500nm

Photometric Range 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)

Baseline Flatness +0.002A (200-1000nm)


Noise 0.0003A@500nm

Working Mode T,A,C,E

Wavelength Setting Automatic

Scanning Speed Low, Medium, High (up to 3000nm/min)

Detector Solid Silicon Photodiode

Light Source Tungsten Halogen/Deuterium Lamp

Data Output RS232 Serial, USB Drive, USB HOST

Processor Cortex_M3, 120Mhz

Power Requirements AC 110-220V 50-60Hz


880*690*530mm, 880*690*530mm,
Shipping Dimensions and Weight
27kg | 45kg_| 27kg A5kg
6
UI Designisieinesuny

Photometry
i Abserbrien (Abs) ney 4! oF
=] “Teanend etence (NT) Sample Beam Oo

ifn Enerer | Rafereen Beam 0

@ | Absorbency and transmittance test

Photometry

To test sample solution concentration, you can choose

different methods like coefficient, standard curve, lineari-

Si : - ia ay ty, linear zero crossing and quadratic. Operators can


a AK I VA ||| choose single, double and tri-wavelength and change the
— = : Create Curve Open Cure i tok

= reiancens) “=! coefficients of double and tri-wavelength. Advanced

arithmetic makes curvilinear regression more precise and

test data more accurate.

Quantitative Measurement

Test Time
2. Record List
Slope Cabculate Test Bode do Abserbricn[Abs)

3.000 2 . ,
.
= To test the sample chemical reaction process by fixed
"i Bottom Scale 0.300 Abs
z ne a a WW time scanning the sample solution with fixed wavelength.

ss (2) smert Dere im The equipment can calculate its changing rate after
-o.4

TTT +a
entering the corresponding parameters.

Kinetics Measurement(Time Scanning)


a |
U | Des i g Nisiticone on CQ

Start Yovelength 130.0

oat End Movelength 1100.0 om

i Test Node ds Absorbtion[abs)


5 14 Record List -
ing Top Ecale &. 000 Abs ai
H — os son = To test sample solution absorbency peak, can scan the
F 4.i
[ Woveleneth Interval lom a ame
7 al sample characteristic curve of any wavelength range
Scan Speed a Hermal Speed |

Saabs Phaeton : between 190 and 1100nm. And do the chart overlay and
-O.9 = =

UETETENGENTRY “‘ arithmetic.

Wavelength Scanning(Qualitative Test)

iT if Wavelength No.
— | Ha. Wavelength
(nm) Factor
= = Wavelength | 400, 1.000
= Wavelength 2 450.0 1, 000

— Wavelength 3 500. 1,000


It is much more convenient for users to test the absor-

a | |_| bency or do the arithmetic in case of several wavelengths


for the same sample solution, which is much simpler than

single wavelength testing.

Multi Wavelength Measurement

E r
Formula(DtlA) DNA=(ADBO-AS20)
x62. 9-(APE0-ASI0) 236

Formula(Pro.) Pro, =(A26)-A320) 21552 -(AZE0-A920)


xT HT. 3
Wavelength 1 = 260.0 tu
| Havelength 2 = 2e0.0 nm
Ref, Wavelength = 220.0
Coefficlent 1 = 62.90
Cosfficlent 2 = 36.00

Coefficient $= 1562
Cosfficient 2 = TST.3
It is a special function for specific users and make the
operation easier.

DNA/Protein Measurement
| P | 7 inch touch screen

International advanced xenon light (Hamamatsu) source makes the instrument more stable and reliable. Three

years warranty. Adopt the newest microcomputer technology and electronic control system. Optimized optical

system and structure can both extend new functions and ensure the accuracy, stability and durability.

Main Features
* 7 inch TFT screen and long life, more comfortable and sensitive silicone buttons or capacitive touch screen.

The instrument can show various scanning curves and charts for users to complete various tests without

computers.

* Support USB storage and different data formats such as Excel, txt and photos(*.csv, *.qua,*.txt,*.bmp) . Users

can output test data to flash memory, open and edit them on computers directly without any auxiliary software.

* Advanced hardware and 32-bit Cortex_M3 processor with the clock speed 120MHz. The equipment can store

5000 pieces of data and 500 curves.

* High-efficiency holographic grating of 1200 lines/mm and ultra-low stray light.

* The equipment has Long-life socket type xenon lamp which can work up to 5000 hours. Socket type lamp

makes the replacement much easier.

* Excellent silicon photodiode can guarantee the equipment is highly sensitive and stable.

* Huge sample chamber and various accessories can meet all kinds of needs.

* Can be connected to printer directly and output test charts and data.

* Powerful PC software.

* Strong extended capability: Standard 8GB memory can store huge test data and equipped with RS232, HOST

USB port and standard USB interface.


9
_ ss X-8200 hI
Specifications
MODEL X-8200 | X-8200S | X-8200A | X-8200T |X-8200TS| X-8200TA

Display 7 inch TFT 7 inch TFT

Keyboard Control Silicone Buttons Touch Screen

Double Beam
Optical System
Holographic grating, 1200 lines/mm

Slit Width 2nm inm ht 2, 2nm inm oe 2,

Wavelength Range 190 - 1100nm

Wavelength Accuracy +0.6nm

Wavelength Repeatability <0.2nm

Photometric Accuracy 0.3%T (0-100%T) , +0.005A(0-0.5A) , +0.01A(0.5-1A)

Photometric Repeatability <0.2%T (0-100%T), 0.003A(0-0.5A), 0.005A (0.5-1A)

Stray Light <0.1%T@220nm, 360nm

Stability +0.002A/h@500nm

Photometric Range 0-200%T, -0.3-3.0A, 0-9999C (0-9999F)

Baseline Flatness +0.002A (200-1000nm)

Noise 0.002A@500nm

Working Mode T,A,C,E

Wavelength Setting Automatic

Scanning Speed Low, Medium, High (up to 3000nm/min)

Detector Solid Silicon Photodiode

Light Source Xenon Lamp

Data Output RS232 Serial, USB Drive, USB HOST

Processor Cortex_M3, 120Mhz

Power Requirements AC 110-220V 50-60Hz


Shipding Dimensions:and Weight — errs SiG saree som

10
oo si-9100/9200
Introduction
Excellent optical system, high level mechanical

system, advanced circuit control system,

rigorous production process, friendly and

intuitive software interface, good technical

specifications, stable and reliable performance

can meet the analysis requirements from high

level and professional customers.

Main Features
Appearance and internal structure

Modern and elegant appearance, extendable design, separate structure design for optical and circuit system can

efficiently avoid the loss of photometric energy.

Convenient and intuitive operation interface

This series has 7-inch high resolution colored capacitive touch screen and newly developed UV-SUPER2.0 software

with strong functions, which make the operation simple and easy.

Excellent performance and stability

Totally enclosed monochromator and optical mirror coated with SiO2 guarantee the optical components are not

influenced by gas and environment.

@ Philips and Milas lamps.


@ Newly improved screw pole drive structure makes good wavelength repeatability and high wavelength accuracy.

© Totally new design, superior materials and rigorous production process.


Advanced photoelectric test system

@ 32 bit ARM11 microcontroller with clock speed up to 533MHz.

@ 20 bit analog digital device specialized for photoelectric data collection and processing from BB company.

© Support internal huge data storage, mouse operation and big SD card memory.

Simple and convenient maintenance

@ Socket type lamps make the optical adjustment not necessary and maintenance much easier.

@ Separated Optical and circuit system has no cross influence and make the instrument more reliable.

11
T-9100/9200

Specifications
MODEL T-9100 T-9200 T-9200S T-9200A

Display 7 inch TFT colored capacitive touch screen

Wavelength Range 190 - 1100nm

Optical System Single Beam Double Beam

Spectral Bandwidth 2nm 2nm inm 0.5,1,2,4nm

Wavelength Accuracy +0.5nm +0.5nm +0.3nm +0.3nm

Wavelength Repeatability <0.2nm <0.2nm <0.2nm <0.2nm

Photometric Range 0-200%¥T, -0.3-3.0A, 0-9999C (0-9999F)

Photometric Accuracy 0.2%T (0-100%T), +0.002A(0-0.5A), +0.004A(0.5-1A)


Photometric Repeatability <0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Scanning Speed Low, Medium, High (up to 3000nm/min)

Stray Light 30.05% T@220nm,360nm

Baseline Flatness +0.003A +0,002A +0,002A +0.002A


Drift 0.003A/30min 0.002A/30min 0.002A/30min 0.002A/30min
@500nm @500nm @500nm @500nm

Noise 0.0003A@500nm

Working Mode T,A,C,E

Wavelength Setting Automatic

Detector Solid Silicon Photodiode

Light Source Tungsten Halogen/Deuterium Lamp

Output Port USB HOST, USB DRIVE, RS232

Power Requirements AC 110-220V 50-60Hz

Humidity Range Less Than 85%

Shipping Dimensions and Weight 770*630*340mm, 27kg a ail,

12
U | Des [ g n (Touch —_— —™


—® Photometry

Text

1.032 abs
Wavelengh Sample Position

[ 156.43
nm | EC

Absorbency and transmittance test

Photometry

Quantitation
To test sample solution concentration, you can choose
Test List Data

156.03 ug/ul different methods like coefficient, standard curve, lineari-


Wavelengh
ty, linear zero crossing and quadratic. Operators can
Sample Position choose single, double and tri-wavelength and change the

coefficients of double and tri-wavelength. Advanced

arithmetic makes curvilinear regression more precise and

test data more accurate.

Quantitative Measurement

Deat

156.03 abs
Wavelengh
one
E
=

To test the sample chemical reaction process by fixed


(syn

~| Sample Position

time scanning the sample solution with fixed wavelength.

oy :
The equipment can calculate its changing rate after
Save EJ fe Ti Delete Gone } Print

entering the corresponding parameters.

Kinetics Measurement(Time Scanning)

13
_ = 4 Ul Design cwnseun
Vavelength Scan

To test sample solution absorbency peak, can scan the

sample characteristic curve of any wavelength range

between 190 and 1100nm. And do the chart overlay and

arithmetic.

Wavelength Scanning(Qualitative Test)

Text List Date


(2 190 210 300 © 500 © 700» 800-900 10001100 jum 0 863 Abs
oT 0.210 0410 0.210 O270 O280 O970 0210 0210 O210 ze

oF 0210 0410 O270 0.270 0280 O910 8210 O210 oO210 Wavelengh

Nomen rection It is much more convenient for users to test the absor-

bency or do the arithmetic in case of several wavelengths


| Text |

for the same sample solution, which is much simpler than

single wavelength testing.

Multi Wavelength Measurement

tein/DNA Text

Text List Bata


ic" 100 Abs 600Abs 400Abs ER Saeicem) ee cum
ia) O.210 0.410 0.210 O90 O210 0.210
0.863 abs
a2 O.210 410 0.210 O.310 o210 a2 Wavelength
a210 ago © a.210 o2zi0 [X)

a th a
It is a special function for specific users and make the
Il] Delete (aa) Print

operation easier.

DNA/Protein Measurement

14
uble Beam)
ve tt e ho ld er (Standard for Do
Single-hole cu
ng} e beam)
cel l ho ld er (standard for si
on
Manual 4-positi

holder
on 40cm cell
Manual 4-positi
holder
tion round cell
Automatic 8-posi

—aq
holder
Single hole film

Man ual 4-positi


on film holder

er
micro cell hold
Adjustable XY
Tube rack
lder
optical path ho
Single hole long
UV/Vis. eae Display | Slit Width yey see Stray Light | Light Source |Page
E-1000V Vis Tungsten Halogen
Single |70*40mmLcb| 4nm +2 nm <1 nm <0.15%T@360nm ee Halogen)
E-1000UV| UV /Deuterium Lamp
, Tungsten Halogen
C-7000V | Vis. Lamp aA

C-7000UV Single 2nm


<0.05%T
C-7100 @220nm,360nm
C-71008 1nm

C-7100A F 0.5,1,2,4nm
ae Tungsten Halogen
a UV 7 inch FTF 3 +0.3 nm s0.2 nm iDeutetum Lame 5/8
nm

C-7200S8 1 nm <0.03%T
@220nm,360nm
C-7200A Doubts 0.5,1,2,4 nm

C-7200PC 1, 2nm

X-8200 2nm

X-8200S 7 inch FTF 1nm

X-8200A 0.5,1,2,4 nm <0.1%T


xa200T UV | Double nm +0.6 nm <0.2 nm @220 nm,360nm Xenon Lamp 9/10

X-8200TS Touch Screen 1 nm

X-8200TA 0.5,1,2,4nm

T-9100 Single
2nm +0.5 nm $0.2 nm

1-8200 UV Touch Screen $0.05%T Tungsten Halogen 11/14


T-92008 Double 4 nm @220nm,360nm | /Deuterium Lamp
+0.3 nm $0.2 nm
T-9200A 0.5,1,2,4,nm

16
PEAK Instruments Inc.
Address: 16223 Park Row, Suite # 105, Houston, TX-77084, USA.
Tel.: +1 2819353455
Fax: +1 2815780806
E-mail: [email protected]
Website: www.peakii.com