VEGAII

ELECTRONIC COUNTER

PROGRAMMING PARAMETERS
FIRMWARE “M3.02M01.XXE”
CODE : MA/0721/02/EN/01
REVISION : 05/2018

Isoil Impianti S.p.A. - Italy


Sede e stabilimento Uffici Commerciali Sede legale
Head office and factory Sales office Registered office
24061 Albano S.Alessandro (BG) 20092 Cinisello Balsamo (MI) 20124 Milano
74, via Madonna delle Rose 27, via F.lli Gracchi 24, viale Vittorio Veneto
Tel. +39 035 4239.011 Tel. +39 02 66027.1 Capitale soc. int. Sottoscritto 774.000 Euro
Fax +39 035 582078 Fax +39 02 66012456 Codice Fisc. e part. IVA 13066900153
E-mail : [email protected] E-mail : [email protected] C.C.I.A.A. MI - Reg. Impr. 86449/2000
Web : www.isoilmeter.com [email protected] R.E.A. Milano 1612783
INDEX
INTRODUCTION ..................................................................................................................................................................................................................... 6
 Programming ............................................................................................................................................................................................................................ 6
 Using the parameter programming keys ..................................................................................................................................................................................... 7
 Accessing the parameters .......................................................................................................................................................................................................... 8
 Parameters features ................................................................................................................................................................................................................ 10
0 METERS .......................................................................................................................................................................................................................... 16
Serial number ................................................................................................................................................................................................................................ 16
Counting acquisition ....................................................................................................................................................................................................................... 16
K-Factor ........................................................................................................................................................................................................................................ 18
Meter Factor .................................................................................................................................................................................................................................. 18
Correction curve ............................................................................................................................................................................................................................ 19
Flow rates ..................................................................................................................................................................................................................................... 25
Measurement units/Comp. Table .................................................................................................................................................................................................... 26
Mass adjustment ........................................................................................................................................................................................................................... 29
Measurable quantity ....................................................................................................................................................................................................................... 29
Density acquisition ......................................................................................................................................................................................................................... 29
Temperature acquisition ................................................................................................................................................................................................................. 31
Pressure acquisition ....................................................................................................................................................................................................................... 32
1 PRODUCTS ..................................................................................................................................................................................................................... 33
Products number ........................................................................................................................................................................................................................... 33
Units of measurement .................................................................................................................................................................................................................... 33
Displays ........................................................................................................................................................................................................................................ 34
Displays ........................................................................................................................................................................................................................................ 35
Name ............................................................................................................................................................................................................................................ 35
Temperature range ........................................................................................................................................................................................................................ 36
Density range ................................................................................................................................................................................................................................ 37
PTB Biofuels coefficients................................................................................................................................................................................................................. 40
Totalizers ...................................................................................................................................................................................................................................... 43
Pressure range .............................................................................................................................................................................................................................. 44
Equilibrium pressure method .......................................................................................................................................................................................................... 45
Pe fixed value ................................................................................................................................................................................................................................ 45
Pe interpolation factor .................................................................................................................................................................................................................... 46
2 VEGA CONFIGURATION ................................................................................................................................................................................................. 47
Date and time ............................................................................................................................................................................................................................... 47
Switch off delay ............................................................................................................................................................................................................................. 47
Optional boards presence ............................................................................................................................................................................................................... 47
VEGA serial number/position .......................................................................................................................................................................................................... 47
Custom unit of measurement.......................................................................................................................................................................................................... 48
Serial addresses ............................................................................................................................................................................................................................. 48
Communication protocol ................................................................................................................................................................................................................. 48

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°3 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
Decimal separator character .......................................................................................................................................................................................................... 49
Display board ................................................................................................................................................................................................................................ 49
Inferred measures ......................................................................................................................................................................................................................... 49
Speed Can-Bus.............................................................................................................................................................................................................................. 49
3 ALARMS.......................................................................................................................................................................................................................... 50
Pulses emitter ............................................................................................................................................................................................................................... 50
Flow rate ...................................................................................................................................................................................................................................... 51
Valves .......................................................................................................................................................................................................................................... 53
Selecting valve of Prod.1 ............................................................................................................................................................................................................... 55
Selecting valve of Prod.2 ............................................................................................................................................................................................................... 55
Selecting valve of Prod.3 ............................................................................................................................................................................................................... 56
Vapour recovery not opened .......................................................................................................................................................................................................... 56
Vapour recovery not closed ............................................................................................................................................................................................................ 57
PT100 temperature probe .............................................................................................................................................................................................................. 58
Products temperature .................................................................................................................................................................................................................... 58
Densitometer/Alpha/ Alcoholic Strength 4-20mA ............................................................................................................................................................................. 63
Pressure out of range .................................................................................................................................................................................................................... 63
Internal temperature ..................................................................................................................................................................................................................... 64
Internal battery ............................................................................................................................................................................................................................. 65
Switch off with flow ....................................................................................................................................................................................................................... 65
Remote START locked ................................................................................................................................................................................................................... 65
Remote STOP locked ..................................................................................................................................................................................................................... 65
Products selector ........................................................................................................................................................................................................................... 66
Input 4-20mA .............................................................................................................................................................................................................................. 66
Additives....................................................................................................................................................................................................................................... 67
Additivators by signals ................................................................................................................................................................................................................... 69
Serial lines timeout ........................................................................................................................................................................................................................ 69
Product leak .................................................................................................................................................................................................................................. 71
High flow rate too low ................................................................................................................................................................................................................... 72
Keyboard ...................................................................................................................................................................................................................................... 72
Emergency functions ..................................................................................................................................................................................................................... 73
SYSTEM ALARM TABLE ................................................................................................................................................................................................................. 75
METER 1 ALARM TABLE ................................................................................................................................................................................................................ 77
METER 2 ALARM TABLE ................................................................................................................................................................................................................ 78
5 PASSWORDS .................................................................................................................................................................................................................. 79
Passwords ................................................................................................................................................................................................................................. 79
6 SERIAL LINES ................................................................................................................................................................................................................ 80
Serial line 1 (RS232/485) ............................................................................................................................................................................................................... 80
Serial line 2 (RS232/485) ............................................................................................................................................................................................................... 81
Serial line 3 (RS422/485) ............................................................................................................................................................................................................... 82
Serial line 4 (RS232) ...................................................................................................................................................................................................................... 83
7 AUTOMATION................................................................................................................................................................................................................. 84

Page n°4 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
Operating mode ............................................................................................................................................................................................................................. 84
Local mode .................................................................................................................................................................................................................................... 84
Remote mode ................................................................................................................................................................................................................................ 85
Preset ........................................................................................................................................................................................................................................... 86
Pin code/Badge ............................................................................................................................................................................................................................. 86
Product selection mode .................................................................................................................................................................................................................. 86
Transactions & batches number ...................................................................................................................................................................................................... 87
Inputs .......................................................................................................................................................................................................................................... 87
Outputs ........................................................................................................................................................................................................................................ 93
Valves .......................................................................................................................................................................................................................................... 99
Print............................................................................................................................................................................................................................................ 105
LFD-6 display .............................................................................................................................................................................................................................. 108
Gas extractor .............................................................................................................................................................................................................................. 108
8 ADDITIVATION ............................................................................................................................................................................................................ 109
General....................................................................................................................................................................................................................................... 109
Recipes ....................................................................................................................................................................................................................................... 110
FlexiMix ...................................................................................................................................................................................................................................... 112
Additive A ................................................................................................................................................................................................................................... 113
Additive B ................................................................................................................................................................................................................................... 114
Additive C ................................................................................................................................................................................................................................... 115
Additive D ................................................................................................................................................................................................................................... 116
Additive E ................................................................................................................................................................................................................................... 117
Additive F ................................................................................................................................................................................................................................... 118
9 DIFFERENTIAL ............................................................................................................................................................................................................. 119
Differential 1 ............................................................................................................................................................................................................................... 119
Differential 2 ............................................................................................................................................................................................................................... 119
Differential 3 ............................................................................................................................................................................................................................... 119

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°5 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
INTRODUCTION

 Programming

VEGA must be programmed to be associated in the right way with the others components of the measuring system.

The programming parameters fall into two categories:


- METROLOGICAL PARAMETERS;
- AUTOMATION PARAMETERS.

A level of protection is associated to each parameter depending on its characteristics.

LEVEL 1 (needed for all METROLOGICAL PARAMETERS)

These parameters can only be modified:


- using the LEVEL 1 password (see parameter 5.1);
- If the Weight & Measure switch is completely extracted.

LEVEL 2

These parameters can only be modified:


- By entering the LEVEL 1 (see parameter 5.1) or LEVEL 2 password (see parameter 5.2);

Page n°6 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
 Using the parameter programming keys
The parameters can be programmed using:
- the keyboard on the front panel of the VEGA;
- the “virtual keyboard” shown on the display;
- A remote system connected to VEGA via a serial communication line.

VEGAII

The keys for VEGAII have the following functions:

- "” e “” : to move within a menu or to select the elements shown on the screen;
- “ENTER” : to access and change the value of the parameter and to confirm the new entered/selected value;
- “0-9” : to enter numerical values;
- “SET” : to exit from panel with “virtual keyboard” (alphanumerical values) without saving value entered;
- “CLEAR” : to delete the values or quit the menu and go back to the previous one;
- “STOP RIGHT” : to enter a decimal point;
- “STOP LEFT” : to enter a negative sign.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°7 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
 Accessing the parameters
To enter and exit into the parameter programming mode, press the two keys "” and “” at the same time and wait one or two seconds for VEGAII.

Use the two keys "” and “” to scroll the menu options. Find the required option "Parameters setting" and press "ENTER".

For entering the password use keys "0-9" on the keyboard followed by "ENTER" to confirm the value.

Page n°8 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
There are four passwords of accessing to Parameters setting:

The password LEVEL 1 (see PASSWORDS menu option parameter 5.1) allows:
- to modify “METROLOGICAL PARAMETERS” protected by weight & measure switch if this is removed;
- to modify “AUTOMATION PARAMETERS” not protected by weight & measure switch;

Password LEVEL 2 (see PASSWORDS menu option parameter 5.2) allows:


- to read “METROLOGICAL PARAMETERS” protected by weight & measure switch;
- to modify “AUTOMATION PARAMETERS” not protected by weight & measure switch;

Password READING PARAMETERS (see PASSWORDS menu option parameter 5.3) allows:
- to read “METROLOGICAL PARAMETERS” protected by weight & measure switch;
- to read “AUTOMATION PARAMETERS” not protected by weight & measure switch;

Password ISOIL TECHNICIAN (classified) allows to:


- read “METROLOGICAL PARAMETERS” protected by weight & measure switch;
- read “AUTOMATION PARAMETERS” not protected by weight & measure switch;
by this password ISOIL Technician can check values of parameters without know values of password parameters (parameters 5.1, 5.2, 5.3).

If the password isn't valid, the following page appears

Otherwise

Press "ENTER" to go to the parameter group menu.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°9 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
 Parameters features
Each parameter is characterized by:

Identification number: Each parameter is identified by a number that shows position and path for research it.
Example:
0 – Meter
0.1 – Meter serial number /pos.
0.2 - Pulses emitter
0.2.1 – Type of pulses emitter
0.2.2 – Sense of meter rotation

Value: Value of parameter.

Minimum value: The minimal value that the parameter can assume.

Maximum value: The maximum value that the parameter can assume.

Protection level: It indicates the level of protection of the parameter:


1 = to modify parameter you have to enter password of level 1 and remove Weight & Measure switch;
2 = to modify parameter you have to enter password of level 2;
3 = to modify parameter you have to enter password of ISOIL TECHNICIANS.

In the panel of parameter are shown some icons that indicate:

Level of protection;

If it’s shown key means that weight & measure switch is present else weight & measure switch is not present;

When it’s shown empty circle parameter modification is possible.

Description : In the panel there is a short description to explain the parameter function.

After inserting the correct password VEGA displays the menu with the main groups of parameters.
By using one of the two keys "" and "" you can scroll the menu. To enter in a group of parameters press key "ENTER".
In order to return to the previous menu you can select "Closes Menu" or press the key "CLEAR".

Page n°10 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
Select " 0-Meters " pressing key "ENTER".

Select " 0.1.1 – Meter serial number ". VEGA shows panel where you can find :
- Identification number = 0.1.1 – Meter serial number
- Value = ----------------

- Protection level =

- Weight & measure switch presence =

- Modification doesn’t forbid =

If you try to modify parameter without removing weight & measure switch a clear message is shown on display. In order to close message press button " ENTER " of VEGA.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°11 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
If you remove Weight & Measure switch for modifying parameter you have to:
- use " ENTER " to start modify;

- " CLEAR " to delete last character.

- "0-9 " to insert new value (if you press more time the same button all possible characters of button are shown).

- use " ENTER " to confirm the value.

Page n°12 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
Now select parameter " 0.1.2 – Pulses emitter ".

The panel displays a description of parameter that can help the operator. In this panel there are two legally parameters; in order to go from one parameter to another one use " " and " ".

By pressing the key " ENTER " on the evidenced parameter will be visualized a list of possible values.
Using the keys " " and " " to scroll the values and press " ENTER " to set the value evidenced in that moment.

Now we can set parameter "0.2.2 – Sense of meter rotation". To change the value “CLOCKWISE” with the value “ANTICLOCKWISE” we have to repeat the same operations described before.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°13 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
Go on virtual push-button and press button " ENTER " to confirm the new value and to return to main menu.

Now select parameter " 0.3 - K Factor ".

Value of this parameter is a numeric value.

Page n°14 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
To modify the value press button " ENTER ", now value should begin to flash.

Use the keys from " 0 " to " 9 ", "RIGHT STOP" to introduce decimal point for VEGAII, and press key "ENTER " to confirm new value.

Go on virtual push-button and press button " ENTER " to confirm new values of the parameter and to return to main menu.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°15 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0 METERS
0.1 Meter 1 0.2 Meter 2
0.1.1 Serial number 0.2.1 Serial number
VALUES
DESCRIPTION Protection
Minimum Maximum DEFAULT
Serial number
These parameters allow entering an alphanumeric code of maximum 15 characters that are the serial 0 characters 15 characters --------------
numbers of the meters that are associated to VEGAII.

0.1 Meter 1 0.2 Meter 2


0.1.2 Counting acquisition 0.2.2 Counting acquisition
0.1.2.1 Source of acquisition 0.2.2.1 Source of acquisition
0.1.2.1.1 Acquisition source 0.2.2.1.1 Acquisition source
0.1.2.1.2 Meter rotation sense 0.2.2.1.2 Meter rotation sense
0.1.2.1.3 Type of counting 0.2.2.1.3 Type of counting
0.1.2.1.4 Filter percentage 0.2.2.1.4 Filter percentage
DESCRIPTION VALUES Protection
Acquisition source Pulses (0)
Specify the source used for the counting of product. EM6422 CanBus (1)
ModBus (Default) (2)
Meter rotation sense Anticlockwise (0)
It allows to set the meter rotation sense: clockwise, anticlockwise or not managed. Clockwise (Default) (1)
This parameter is not used with ModBus source of acquisition.. Not managed (2)
Type of counting Only incremental(Default) (0)
It allows to define if the quantity must be counted in both directions or only in one direction. Incremental/decremental (1)
This parameter is not used with ModBus source of acquisition.
Filter percentage Min. Max Default
It defines the filter on the noise than can be present on pulses.
0% 100 % 0%
The filter is used only out of batch delivery.

0.1 Meter 1 0.2 Meter 2


0.1.2 Counting acquisition 0.2.2 Counting acquisition
0.1.2.2 Pulses 0.2.2.2 Pulses
DESCRIPTION VALUES Protection
Emitter channels Only channel (A) (0)
It allows to define the used channel for the pulses emitter. Only channel (B) (1)
Two channels (Default) (2)

0.1 Meter 1 0.2 Meter 2


0.1.2 Counting acquisition 0.2.2 Counting acquisition
0.1.2.3 EM6422 CanBus 0.2.2.3 EM6422 CanBus
VALUES
DESCRIPTION Default Protection
Min. Max
Meter 1 Meter 2
Address
1 127 21 22
It defines the address used to communicate with the pulses emitter EM6422 CanBus

Page n°16 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.2 Counting acquisition 0.2.2 Counting acquisition
0.1.2.4 ModBus 0.2.2.4 ModBus
0.1.2.4.1 Address 0.2.2.4.1 Address
0.1.2.4.2 Function code 0.2.2.4.2 Function code
0.1.2.4.3 Register number of gross volume 0.2.2.4.3 Register number of gross volume
0.1.2.4.4 Value of gross volume overflow 0.2.2.4.4 Value of gross volume overflow
0.1.2.4.5 Data type of gross volume 0.2.2.4.5 Data type of gross volume
0.1.2.4.6 Register number of mass 0.2.2.4.6 Register number of mass
0.1.2.4.7 Value of mass overflow 0.2.2.4.7 Value of mass overflow
0.1.2.4.8 Data type of mass 0.2.2.4.8 Data type of mass
0.1.2.4.9 Register number of flow rate 0.2.2.4.9 Register number of flow rate
0.1.2.4.10 Data type of flow rate 0.2.2.4.10 Data type of flow rate
DESCRIPTION VALUES
Protection
Min. Max Default
Address Meter 1 Meter 2
It defines the address used to communicate with Legally relevant ModBus. 0 247
247 246
Function code 03 Read Holding Registers (Default) (0)
It defines the function code of standard ModBus used to acquire the registers of counting. 04 Read Input Registers (1)
Register number of gross volume
0 99999 0
It defines the number of the register to read to acquire the gross volume.
Value of gross volume overflow
0,001 100000000,000 10000000,000
It defines the maximum value represented in the register beyond the value come back to 0.
Data type of gross volume Integer (32 bit) (0)
It defines the type of data used to represent the gross volume. Float (32bit) (Default) (1)
Double (64 bit) (2)
Register number of mass
0 99999 45053
It defines the number of the register to read to acquire the mass.
Value of mass overflow
0,001 100000000,000 10000000,000
It defines the maximum value represented in the register beyond the value come back to 0.
Data type of mass Integer (32 bit) (0)
It defines the type of data used to represent the mass. Float (32bit) (Default) (1)
Double (64 bit) (2)
Register number of flow rate
0 99999 45051
It defines the number of the register to read to acquire the flow rate.
Data type of flow rate Integer (32 bit) (0)
It defines the type of data used to represent the flow rate. Float (32bit) (Default) (1)
Double (64 bit) (2)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°17 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.3 K-Factor 0.2.3 K-Factor
VALUES
DESCRIPTION Protection
Minimum Maximum DEFAULT
K-Factor
Number of pulses that are needed for obtaining a unit of measurement. 0,0001 99999,9999 10
For emitter EM6422 see table below.

Number of pulses for every model of ISOIL PDmeter fitted with pulse emitter EM6422 64 pulses/revolution
ISOIL PDmeter Pulses/liter ISOIL PDmeter Pulses/liter ISOIL PDmeter Pulses/liter
SBM 32 133,056 BM 200 28,131 LBM 1000 4,33
SBM 75 102,4 BM 400 14,065 LBM 3000 2,166
SBM 150 28,131 BM 600 9,377
S 9000 13,0 P 4000 13,0

0.1 Meter 1 0.2 Meter 2


0.1.4 Meter Factor 0.2.4 Meter Factor
0.1.4.1 Product 1 0.1.4.2 Product 2 0.1.4.3 Product 3 0.2.4.1 Product 1 0.2.4.2 Product 2 0.2.4.3 Product 3
VALUES
DESCRIPTION Protection
Minimum Maximum Default
Meter Factor
Multiplicative correction factor applied to compensate the difference between the nominal number of pulses “K-
Factor" and the real number of pulses for every unit of measurement.
Value to input can be calculated in two ways:

 VOLUME

GROSS VOLUME OF PROVING TANK 1 – (Par. 0.1.4.4/1000) 1 + (Par. 0.1.4.4/1000)


VALUE TO INPUT = ----------------------------------------------- or or
1.00000
GROSS VOLUME OF VEGA 1 – (Par. 0.2.4.4/1000) 1 + (Par. 0.2.4.4/1000)

 NET VOLUME

NET VOLUME OF PROVING TANK


VALUE TO INPUT = -------------------------------------------
NET VOLUME OF VEGA

Final value of parameter will be: METER FACTOR = METER FACTOR * VALUE TO INPUT

Page n°18 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.4 Meter Factor 0.2.4 Meter Factor
0.1.4.4 Maximum correction with Meter-Factor 0.2.4.4 Maximum correction with Meter-Factor
VALUES
DESCRIPTION Protection
Minimum Maximum Default
Maximum correction with Meter-Factor
Maximum correction that can be applied by the Meter-Factor (including the correction curves). The value is expressed in ‰ (per
thousand). 0‰ 200 ‰ 200 ‰
Example: with this parameter set at 200, the maximum correction will be between 1 - (200/1000) and 1 + (200/1000), specifically 0.8
and 1.2.

0.1 Meter 1 0.2 Meter 2


0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.1 Product 1 0.1.5.2 Product 2 0.1.5.3 Product 3 0.2.5.1 Product 1 0.2.5.2 Product 2 0.2.5.3 Product 3
0.1.5.1.1 Enabling 0.1.5.2.1 Enabling 0.1.5.3.1 Enabling 0.2.5.1.1 Enabling 0.2.5.2.1 Enabling 0.2.5.3.1 Enabling
DESCRIPTION VALUES Protection
Enabling Enabled (0)
It enables/disables the “Correction curve” of the meter. If enabled must be introduced a minimum of 2 flow rate values with Disabled (Default)
(1)
their Meter Factors and a maximum of 10 flow rate values.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°19 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.1 Product 1 0.1.5.2 Product 2 0.1.5.3 Product 3 0.2.5.1 Product 1 0.2.5.2 Product 2 0.2.5.3 Product 3
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Flow rate point 1 0.1.5.1.2 PRODUCT 1 METER 1 Par. 0.1.6.1 Par. 0.1.6.2 00000
Flow rate of the Meter-Factor point 1 0.1.5.2.2 PRODUCT 2 METER 1 Par. 0.1.6.1 Par. 0.1.6.2 00000
0.1.5.3.2 PRODUCT 3 METER 1 Par. 0.1.6.1 Par. 0.1.6.2 00000
0.2.5.1.2 PRODUCT 1 METER 2 Par. 0.2.6.1 Par. 0.2.6.2 00000
0.2.5.2.2 PRODUCT 2 METER 2 Par. 0.2.6.1 Par. 0.2.6.2 00000
0.2.5.3.2 PRODUCT 3 METER 2 Par. 0.2.6.1 Par. 0.2.6.2 00000
Meter-Factor point 1 1.00000 - 1.00000 +
The value to set must be calculated in this way: 0.1.5.1.3 PRODUCT 1 METER 1 1.00000
(Par. 0.1.4.4 / 1000) (Par. 0.1.4.4 / 1000)
VOLUME
1.00000 - 1.00000 +
TANK PROVER VOLUME 0.1.5.2.3 PRODUCT 2 METER 1 1.00000
(Par. 0.1.4.4 / 1000) (Par. 0.1.4.4 / 1000)
Meter-Factor = -----------------------------------
VOLUME MEASURED (VEGA) 1.00000 - 1.00000 +
0.1.5.3.3 PRODUCT 3 METER 1 1.00000
(Par. 0.1.4.4 / 1000) (Par. 0.1.4.4 / 1000)
NET VOLUME 1.00000 - 1.00000 +
TANK PROVER NET VOLUME 0.2.5.1.3 PRODUCT 1 METER 2 1.00000
(Par. 0.2.4.4 / 1000) (Par. 0.2.4.4 / 1000)
Meter-factor = -------------------------------------------------
1.00000 - 1.00000 +
NET VOLUME MEASURED (VEGA) 0.2.5.2.3 PRODUCT 2 METER 2 1.00000
(Par. 0.2.4.4 / 1000) (Par. 0.2.4.4 / 1000)
1.00000 - 1.00000 +
0.2.5.3.3 PRODUCT 3 METER 2 1.00000
(Par. 0.2.4.4 / 1000) (Par. 0.2.4.4 / 1000)
Flow rate point 2 0.1.5.1.4 PRODUCT 1 METER 1 Par. 0.1.5.1.2 Par. 0.1.6.2 00000
0.1.5.2.4 PRODUCT 2 METER 1 Par. 0.1.5.1.2 Par. 0.1.6.2 00000
0.1.5.3.4 PRODUCT 3 METER 1 Par. 0.1.5.1.2 Par. 0.1.6.2 00000
0.2.5.1.4 PRODUCT 1 METER 2 Par. 0.1.5.1.2 Par. 0.2.6.2 00000
0.2.5.2.4 PRODUCT 2 METER 2 Par. 0.1.5.1.2 Par. 0.2.6.2 00000
0.2.5.3.4 PRODUCT 3 METER 2 Par. 0.1.5.1.2 Par. 0.2.6.2 00000
Meter-Factor point 2 Par. 0.1.5.1.3 – Par. 0.1.5.1.3 +
0.1.5.1.5 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.3 – Par. 0.1.5.2.3 +
0.1.5.2.5 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.3 – Par. 0.1.5.3.3 +
0.1.5.3.5 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.3 – Par. 0.2.5.1.3 +
0.2.5.1.5 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.3 – Par. 0.2.5.2.3 +
0.2.5.2.5 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.3 – Par. 0.2.5.3.3 +
0.2.5.3.5 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)

Page n°20 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.1 Product 1 0.1.5.2 Product 2 0.1.5.3 Product 3 0.2.5.1 Product 1 0.2.5.2 Product 2 0.2.5.3 Product 3
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Flow rate point 3 0.1.5.1.6 PRODUCT 1 METER 1 Par. 0.1.5.1.4 Par. 0.1.6.2 00000
0.1.5.2.6 PRODUCT 2 METER 1 Par. 0.1.5.1.4 Par. 0.1.6.2 00000
0.1.5.3.6 PRODUCT 3 METER 1 Par. 0.1.5.1.4 Par. 0.1.6.2 00000
0.2.5.1.6 PRODUCT 1 METER 2 Par. 0.1.5.1.4 Par. 0.2.6.2 00000
0.2.5.2.6 PRODUCT 2 METER 2 Par. 0.1.5.1.4 Par. 0.2.6.2 00000
0.2.5.3.6 PRODUCT 3 METER 2 Par. 0.1.5.1.4 Par. 0.2.6.2 00000
Meter-Factor point 3 Par. 0.1.5.1.5 – Par. 0.1.5.1.5 +
0.1.5.1.7 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.5 – Par. 0.1.5.2.5 +
0.1.5.2.7 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.5 – Par. 0.1.5.3.5 +
0.1.5.3.7 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.5 – Par. 0.2.5.1.5 +
0.2.5.1.7 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.5 – Par. 0.2.5.2.5 +
0.2.5.2.7 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.5 – Par. 0.2.5.3.5 +
0.2.5.3.7 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Flow rate point 4 0.1.5.1.8 PRODUCT 1 METER 1 Par. 0.1.5.1.6 Par. 0.1.6.2 00000
0.1.5.2.8 PRODUCT 2 METER 1 Par. 0.1.5.1.6 Par. 0.1.6.2 00000
0.1.5.3.8 PRODUCT 3 METER 1 Par. 0.1.5.1.6 Par. 0.1.6.2 00000
0.2.5.1.8 PRODUCT 1 METER 2 Par. 0.1.5.1.6 Par. 0.2.6.2 00000
0.2.5.2.8 PRODUCT 2 METER 2 Par. 0.1.5.1.6 Par. 0.2.6.2 00000
0.2.5.3.8 PRODUCT 3 METER 2 Par. 0.1.5.1.6 Par. 0.2.6.2 00000
Meter Factor point 4 Par. 0.1.5.1.7 – Par. 0.1.5.1.7 +
0.1.5.1.9 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.7 – Par. 0.1.5.2.7 +
0.1.5.2.9 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.7 – Par. 0.1.5.3.7 +
0.1.5.3.9 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.7 – Par. 0.2.5.1.7 +
0.2.5.1.9 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.7 – Par. 0.2.5.2.7 +
0.2.5.2.9 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.7 – Par. 0.2.5.3.7 +
0.2.5.3.9 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°21 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.1 Product 1 0.1.5.2 Product 2 0.1.5.3 Product 3 0.2.5.1 Product 1 0.2.5.2 Product 2 0.2.5.3 Product 3
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Flow rate point 5 0.1.5.1.10 PRODUCT 1 METER 1 Par. 0.1.5.1.8 Par. 0.1.6.2 00000
0.1.5.2.10 PRODUCT 2 METER 1 Par. 0.1.5.1.8 Par. 0.1.6.2 00000
0.1.5.3.10 PRODUCT 3 METER 1 Par. 0.1.5.1.8 Par. 0.1.6.2 00000
0.2.5.1.10 PRODUCT 1 METER 2 Par. 0.1.5.1.8 Par. 0.2.6.2 00000
0.2.5.2.10 PRODUCT 2 METER 2 Par. 0.1.5.1.8 Par. 0.2.6.2 00000
0.2.5.3.10 PRODUCT 3 METER 2 Par. 0.1.5.1.8 Par. 0.2.6.2 00000
Meter Factor point 5 Par. 0.1.5.1.9 – Par. 0.1.5.1.9 +
0.1.5.1.11 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.9 – Par. 0.1.5.2.9 +
0.1.5.2.11 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.9 – Par. 0.1.5.3.9 +
0.1.5.3.11 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.9 – Par. 0.2.5.1.9 +
0.2.5.1.11 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.9 – Par. 0.2.5.2.9 +
0.2.5.2.11 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.9 – Par. 0.2.5.3.9 +
0.2.5.3.11 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Flow rate point 6 0.1.5.1.12 PRODUCT 1 METER 1 Par. 0.1.5.1.10 Par. 0.1.6.2 00000
0.1.5.2.12 PRODUCT 2 METER 1 Par. 0.1.5.1.10 Par. 0.1.6.2 00000
0.1.5.3.12 PRODUCT 3 METER 1 Par. 0.1.5.1.10 Par. 0.1.6.2 00000
0.2.5.1.12 PRODUCT 1 METER 2 Par. 0.1.5.1.10 Par. 0.2.6.2 00000
0.2.5.2.12 PRODUCT 2 METER 2 Par. 0.1.5.1.10 Par. 0.2.6.2 00000
0.2.5.3.12 PRODUCT 3 METER 2 Par. 0.1.5.1.10 Par. 0.2.6.2 00000
Meter Factor point 6 Par. 0.1.5.1.11 – Par. 0.1.5.1.11 +
0.1.5.1.13 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.11 – Par. 0.1.5.2.11 +
0.1.5.2.13 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.11 – Par. 0.1.5.3.11 +
0.1.5.3.13 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.11 – Par. 0.2.5.1.11 +
0.2.5.1.13 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.11 – Par. 0.2.5.2.11 +
0.2.5.2.13 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.11 – Par. 0.2.5.3.11 +
0.2.5.3.13 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)

Page n°22 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.1 Product 1 0.1.5.2 Product 2 0.1.5.3 Product 3 0.2.5.1 Product 1 0.2.5.2 Product 2 0.2.5.3 Product 3
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Flow rate point 7 0.1.5.1.14 PRODUCT 1 METER 1 Par. 0.1.5.1.12 Par. 0.1.6.2 00000
0.1.5.2.14 PRODUCT 2 METER 1 Par. 0.1.5.1.12 Par. 0.1.6.2 00000
0.1.5.3.14 PRODUCT 3 METER 1 Par. 0.1.5.1.12 Par. 0.1.6.2 00000
0.2.5.1.14 PRODUCT 1 METER 2 Par. 0.1.5.1.12 Par. 0.2.6.2 00000
0.2.5.2.14 PRODUCT 2 METER 2 Par. 0.1.5.1.12 Par. 0.2.6.2 00000
0.2.5.3.14 PRODUCT 3 METER 2 Par. 0.1.5.1.12 Par. 0.2.6.2 00000
Meter Factor point 7 Par. 0.1.5.1.13 – Par. 0.1.5.1.13 +
0.1.5.1.15 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.13 – Par. 0.1.5.2.13 +
0.1.5.2.15 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.13 – Par. 0.1.5.3.13 +
0.1.5.3.15 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.13 – Par. 0.2.5.1.13 +
0.2.5.1.15 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.13 – Par. 0.2.5.2.13 +
0.2.5.2.15 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.13 – Par. 0.2.5.3.13 +
0.2.5.3.15 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Flow rate point 8 0.1.5.1.16 PRODUCT 1 METER 1 Par. 0.1.5.1.14 Par. 0.1.6.2 00000
0.1.5.2.16 PRODUCT 2 METER 1 Par. 0.1.5.1.14 Par. 0.1.6.2 00000
0.1.5.3.16 PRODUCT 3 METER 1 Par. 0.1.5.1.14 Par. 0.1.6.2 00000
0.2.5.1.16 PRODUCT 1 METER 2 Par. 0.1.5.1.14 Par. 0.2.6.2 00000
0.2.5.2.16 PRODUCT 2 METER 2 Par. 0.1.5.1.14 Par. 0.2.6.2 00000
0.2.5.3.16 PRODUCT 3 METER 2 Par. 0.1.5.1.14 Par. 0.2.6.2 00000
Meter Factor point 8 Par. 0.1.5.1.15 – Par. 0.1.5.1.15 +
0.1.5.1.17 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.15 – Par. 0.1.5.2.15 +
0.1.5.2.17 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.15 – Par. 0.1.5.3.15 +
0.1.5.3.17 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.15 – Par. 0.2.5.1.15 +
0.2.5.1.17 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.15 – Par. 0.2.5.2.15 +
0.2.5.2.17 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.15 – Par. 0.2.5.3.15 +
0.2.5.3.17 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°23 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.1 Product 1 0.1.5.2 Product 2 0.1.5.3 Product 3 0.2.5.1 Product 1 0.2.5.2 Product 2 0.2.5.3 Product 3B
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Flow rate point 9 0.1.5.1.18 PRODUCT 1 METER 1 Par. 0.1.5.1.16 Par. 0.1.6.2 00000
0.1.5.2.18 PRODUCT 2 METER 1 Par. 0.1.5.1.16 Par. 0.1.6.2 00000
0.1.5.3.18 PRODUCT 3 METER 1 Par. 0.1.5.1.16 Par. 0.1.6.2 00000
0.2.5.1.18 PRODUCT 1 METER 2 Par. 0.1.5.1.16 Par. 0.2.6.2 00000
0.2.5.2.18 PRODUCT 2 METER 2 Par. 0.1.5.1.16 Par. 0.2.6.2 00000
0.2.5.3.18 PRODUCT 3 METER 2 Par. 0.1.5.1.16 Par. 0.2.6.2 00000
Meter Factor point 9 Par. 0.1.5.1.17 – Par. 0.1.5.1.17 +
0.1.5.1.19 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.17 – Par. 0.1.5.2.17 +
0.1.5.2.19 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.17 – Par. 0.1.5.3.17 +
0.1.5.3.19 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.17 – Par. 0.2.5.1.17 +
0.2.5.1.19 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.17 – Par. 0.2.5.2.17 +
0.2.5.2.19 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.17 – Par. 0.2.5.3.17 +
0.2.5.3.19 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Flow rate point 10 0.1.5.1.20 PRODUCT 1 METER 1 Par. 0.1.5.1.18 Par. 0.1.6.2 00000
0.1.5.2.20 PRODUCT 2 METER 1 Par. 0.1.5.1.18 Par. 0.1.6.2 00000
0.1.5.3.20 PRODUCT 3 METER 1 Par. 0.1.5.1.18 Par. 0.1.6.2 00000
0.2.5.1.20 PRODUCT 1 METER 2 Par. 0.1.5.1.18 Par. 0.2.6.2 00000
0.2.5.2.20 PRODUCT 2 METER 2 Par. 0.1.5.1.18 Par. 0.2.6.2 00000
0.2.5.3.20 PRODUCT 3 METER 2 Par. 0.1.5.1.18 Par. 0.2.6.2 00000
Meter Factor point 10 Par. 0.1.5.1.19 – Par. 0.1.5.1.19 +
0.1.5.1.21 PRODUCT 1 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.2.19 – Par. 0.1.5.2.19 +
0.1.5.2.21 PRODUCT 2 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.1.5.3.19 – Par. 0.1.5.3.19 +
0.1.5.3.21 PRODUCT 3 METER 1 1.00000
(Par. 0.1.5.4 / 1000) (Par. 0.1.5.4 / 1000)
Par. 0.2.5.1.19 – Par. 0.2.5.1.19 +
0.2.5.1.21 PRODUCT 1 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.2.19 – Par. 0.2.5.2.19 +
0.2.5.2.21 PRODUCT 2 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)
Par. 0.2.5.3.19 – Par. 0.2.5.3.19 +
0.2.5.3.21 PRODUCT 3 METER 2 1.00000
(Par. 0.2.5.4 / 1000) (Par. 0.2.5.4 / 1000)

Page n°24 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.5 Correction curve 0.2.5 Correction curve
0.1.5.4 Difference between adjacent Meter-Factors 0.2.5.4 Difference between adjacent Meter-Factors
VALUES
DESCRIPTION Protection
Minimum Maximum Default
Difference between adjacent Meter-Factors
Maximum difference between adjacent METER FACTORS of the correction curve. The value is expressed in ‰ (per thousand).
Example: If the value is "100" and the value of the first meter-factor is "0.8" the second meter-factor may take a value between:
- 1.00000 - (100/1000) = 0,9 0‰ 200 ‰ 100 ‰
and
- 1.00000 +(100/1000) 1,1.
Setting the value to "0" will disable the control.

0.1 Meter 1 0.2 Meter 2


0.1.6 Flow rates 0.2.6 Flow rates
DESCRIPTION CODE Minimum Maximum Default
Minimum flow rate 0.1.6.1 METER 1 0 Par. 0.1.6.2 200
Minimum value of flow rate at which the measuring system must operate. 0.2.6.1 METER 2 0 Par. 0.2.6.2 200
Maximum flow rate 0.1.6.2 METER 1 Par. 0.1.6.1 99999,999 2000
Maximum value of flow rate at which the measuring system must operate.
0.2.6.2 METER 2 Par. 0.2.6.1 99999,999 2000

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°25 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.7 Measurement units/Comp. Table 0.2.7 Measurement units/Comp. Table
0.1.7.1 Unit of Measurement of pulses 0.2.7.1 Unit of Measurement of pulses
0.1.7.2 Unit of measurement of temperature 0.2.7.2 Unit of measurement of temperature
0.1.7.3 Type of density 0.2.7.3 Type of density
VALUES
DESCRIPTION Protection
Value Description
Unit of measurement of pulses l (0) litres
It allows to set which type of data is represented by the pulses applied on the clamps B4-2 and/or m³ (1) Cubic meters
B4-3. cm³ (2) Cubic centimetres
gal(uk) (3) UK gallons
gal(us) (4) USA gallons
XXXXXXXX (5) Custom unit of measure
Kg (6) Kilograms (Default)
lb (7) Pounds
t (8) Tons
g (9) Grams
Unit of measurement of temperature °C (0) Strength centigrade (Default)
°F (1) Strength Fahrenheit
Type of density Observed density
(0)
VEGAII acquires the density at the instantaneous temperature and
It defines which type of density is acquired by VEGAII. (Default) pressure.

Base density (1) VEGAII acquires the density at the reference temperature and pressure.

Page n°26 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.7 Measurement units/Comp. Table 0.2.7 Measurement units/Comp. Table
0.1.7.4 Volume thermal conversion 0.2.7.4 Volume thermal conversion
0.1.7.5 Tbx °C 0.2.7.5 Tbx °C
VALUES
DESCRIPTION Protection
Value Description
Volume thermal conversion method No one (Default) (0) The conversion is not applied
It allows to select the volume thermal conversion method to calculate the NET VOLUME. TAB. 6A (1) Generalized crude oils - Correction of volume to 60 °F against API gravity at 60 °F
TAB. 6B (2) Generalized products - Correction of volume to 60 °F against API gravity at 60 °F
TAB. 6C (3) Volume correction to 60 °F against thermal expansion coefficients at 60 °F
TAB. 6D (4) Lubrificant oils - Correction of volume to 60°F with API gravity
TAB. 24A (5) Generalized crude oils - Correction of volume to 60 °F against relative density 60/60 °F
TAB. 24B (6) Generalized products - Correction of volume to 60 °F against relative density 60/60 °F
TAB. 24C (7) Volume correction to 60 °F against thermal expansion coefficients at 60 °F
TAB. 24D (8) Lubrificant oils – Correction of volume to 60°F against relative density
TAB. 54 (DIN 71757) (9) Products with density range 550÷653 Kg/m³ -Correction of volume to 15°C against density at 15 °C
TAB. 54A (10) Generalized crude oils - Correction of volume to 15 °C against density at 15 °C
TAB. 54B (11) Generalized products - Correction of volume to 15 °C against density at 15 °C
TAB. 54C (12) Volume correction to 15 °F against thermal expansion coefficients at 60 °F
TAB. 54D (13) Lubricant oils - Correction of volume to 15 °C against density at 15 °C
TAB. 60A (14) Generalized crude oils - Correction of volume to 20 °C against density at 20 °C
TAB. 60B (15) Generalized products - Correction of volume to 20 °C against density at 20 °C
TAB. 60C (16) Volume correction to 20 °F against thermal expansion coefficients at 60 °F
TAB. 60D (17) Lubricant oils - Correction of volume to 20 °C against density at 20 °C
Alfa Tbx°C/F (18) Correction of volume to TX °C against thermal expansion coefficients at TX °C
OIML R22 (19) Ethanol - Correction of volume to 20°C against alcoholic strength by mass.
BRASIL (20) Generalized products - Correction of volume to 20°C against density at 20°C in Brazil
NBR 5992 (21) Ethanol - Correction of volume to 20°C against alcoholic strength by mass in Brazil
PTB BIOFUEL (22) Blend of product biofuel-mineral, blend of oil biofuel-heating, volume correction at 15°C.
Tbx °C Minimum Maximum DEFAULT
Reference temperature for volume thermal conversion with ALPHA Tbx °C. -40°C 250°C +15°C
Type of conversion
CTL (Default) (0) Conversion of volume in temperature.
It defines if the volume conversion is done only in temperature or in temperature and
pressure.
CTPL (1)
Conversion of volume in temperature and pressure.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°27 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
Conversion methods table
Unit of Unit of Type of
Method Description Products Alpha or strength Base density Observed density
measure measure correction
Min. Max Default Min. Max Default Min. Max Default
6A Correction of volume to 60 °F against API gravity Crude oils ------- ------- ------- ------- -10 100 50 -14,3 139.2 50 °API CTL or CTPL
Generalized
6B Correction of volume to 60 °F against API gravity ------- ------- ------- ------- -10 100 42 -14,3 140,6 42 °API CTL or CTPL
products
Volume correction to 60 °F against thermal expansion
6C 0,000230 0,000930 0,000580 ------- -10 100 50 -29,9 147,5 50 °API CTL or CTPL
coefficients at 60 °F
6D Correction of volume to 60°F with API gravity. Lubrificant oils ------- ------- ------- ------- -10 45 45 -14,3 58,9 45 °API CTL or CTPL
24A Correction of volume to 60 °F against relative density Crude oils ------- ------- ------- ------- 0,6112 1,16464 0,8435 0,470946 1,198947 0,8435 Relative density CTL or CTPL
Generalized
24B Correction of volume to 60 °F against relative density ------- ------- ------- ------- 0,6112 1,16464 0,8647 0,470852 1,206597 0,8647 Relative density CTL or CTPL
products
Volume correction to 60 °F against thermal expansion
24C 0,00023 0,00093 0,000580 ------- 0,6112 1,16464 0,8435 0,468610 1,287287 0,8435 Relative density CTL or CTPL
coefficients at 60 °F
0,8016
24D Correction of volume to 60°F with API gravity. Lubrificant oils ------- ------- ------- -------
8
1,1646 0,8647 0,715097 1,206557 0,8647 Relative density CTL or CTPL

Products with density range 550÷653 Kg/m³ - Generalized


54 ------- ------- ------- ------- 500 653 576,5 ------- ------- ------- Kg/m³ CTL
Correction of volume to 15°C against density at 15 °C products
54A Correction of volume to 15 °C against density Crude oils ------- ------- ------- ------- 611,16 1163.79 842,7 470,48 1201,73 842,7 Kg/m³ CTL or CTPL
Generalized
54B Correction of volume to 15 °C against density ------- ------- ------- ------- 611,16 1163,86 864 470,39 1209,39 864 Kg/m³ CTL or CTPL
products
Volume correction to 15 °C against thermal expansion
54C 0,000414 0,001674 0,001044 ------- 611,16 1163,86 864 468.14 1289,47 864 Kg/m³ CTL or CTPL
coefficients at 15°C
54D Correction of volume to 15 °C against density Lubrificant oils ------- ------- ------- ------- 801,25 1163,85 1000 714,39 1205,04 1000 Kg/m³ CTL or CTPL
60A Correction of volume to 20 °C against density Crude oils ------- ------- ------- ------- 606,12 1161,15 841 470,49 1201,73 841 Kg/m³ CTL or CTPL
Generalized
60B Correction of volume to 20 °C against density ------- ------- ------- ------- 606,12 1160,62 862 470,39 1209,4 862 Kg/m³ CTL or CTPL
products
Volume correction to 20 °C against thermal expansion
60C 0,000414 0,001674 0,001044 ------- 606,12 1160,71 862 468,2 1296,05 862 Kg/m³ CTL or CTPL
coefficients at 20°C
60D Correction of volume to 20 °C against density Lubrificant oils ------- ------- ------- ------- 798,11 1160,71 980 714,39 1208,3 980 Kg/m³ CTL or CTPL
All liquid
ALPHA Correction of volume to TX °C against thermal
products other 0,000100 0,002000 0,00105 0,1 1500 1000 0,1 9999,9 1000 Kg/m³ CTL
Tbx °C expansion coefficients at TX °C
than water
Correction of volume to 20°C against alcoholic
OIMLR22 Ethanol 0,1 100 50 % ------- ------- ------- ------- ------- ------- ------- CTL
strength by mass.
Correction of volume to 20°C against density at 20°C Generalized
BRAZIL ------- ------- ------- 0 9999,9 5000 ------- ------- ------- Kg/m³ CTL
in Brazil products
Correction of volume to 20°C against alcoholic
NBR5992 Ethanol 0,1 100 50 % ------- ------- ------- ------- ------- ------- ------- CTL
strength by mass in Brazil
Biofuel-mineral,
fuel mixtures,
PTB BIO Correction of volume to 15°C against density ------- ------- ------- ------- 600 1100 864 400 1250 864 Kg/m³ CTL
biofuel-heating
oil mixtures

Page n°28 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.8 Mass adjustment 0.2.8 Mass adjustment
0.1.8.1 Type 0.2.8.1 Type
0.1.8.2 Density adjustment constant 0.2.8.2 Density adjustment constant
VALUES
DESCRIPTION Protection
Value Description
Mass adjustment type No one (0) The value calculated is Mass (Default)
It allows to convert the Mass (Weight in the vacuum) into Weight in the air. To calculate the weight in the air (NET VOLUME * DENSITY AT
By constant
To calculate weight in air it is possible to subtract from density a constant or multiply density with a (1) 15°c) the density at 15°C is reduced by the value entered in next
value got from table 56 (only for density at 15°C tables 54X)..
value
parameter.
To calculate the weight in the air (NET VOLUME * DENSITY AT
By table 56 (2)
15°c) the density at 15°C is multiplied by the value in the table 56.
Density adjustment constant Minimum Maximum DEFAULT
This parameter can be used to calculate the weight in the air. The density at 15°C is reduced by the 3 3
0.0000 Kg/m 999.9999 Kg/m 1.1 Kg/m3
value entered in this parameter.

0.1 Meter 1 0.2 Meter 2


0.1.9 Measurable quantity 0.2.9 Measurable quantity
DESCRIPTION CODE Minimum Maximum Default
Minimum measurable quantity
0.1.9.1 METER 1 1 999999 200
It allows to set the minimum measurable quantity that should be measured in order
to be metrologically valid.
0.2.9.1 METER 2 1 999999 200
Spurious pulses 0.1.9.2 METER 1 0.1 % 100.0 % 1.0 %
It allows to set the percentage of spurious pulses acceptable respect the quantity
dispensed. 0.2.9.2 METER 2 0.1 % 100.0 % 1.0 %

0.1 Meter 1 0.2 Meter 2


0.1.10 Density acquisition 0.2.10 Density acquisition
0.1.10.1 Source of acquisition 0.2.10.1 Source of acquisition
0.1.10.1.1 Source of acquisition 0.2.10.1.1 Source of acquisition
0.1.10.1.2 Number of decimals 0.2.10.1.2 Number of decimals
DESCRIPTION VALUES Protection
Source of acquisition No one (0)
It defines how the density of product is acquired. Parameters (1)
ModBus (Default) (2)
Input 1 4-20 mA (3)
Input 2 4-20 mA (4)
Number of decimals 1 decimals (Default) (0)
It defines the number of decimals of the density value expressed in kg/m³ 2 decimal (1)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°29 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.10 Density acquisition 0.2.10 Density acquisition
0.1.10.1 Source of acquisition 0.2.10.1 Source acquisition
0.1.10.2 ModBus 0.2.10.2 ModBus
0.1.10.2.1 Address 0.2.10.2.1 Address
0.1.10.2.2 Function code 0.2.10.2.2 Function code
0.1.10.2.3 Register number of density 0.2.10.2.3 Register number of density
0.1.10.2.4 Data type of density 0.2.10.2.4 Data type of density
0.1.10.2.5 Offset 0.2.10.2.5 Offset
0.1.10.2.6 Unit of measure of density acquired 0.2.10.2.6 Unit of measure of density acquired
DESCRIPTION VALUES
Protection
Min. Max Default
Address Meter 1 Meter 2
0 247
It defines the address used to communicate with Legally relevant ModBus. 247 246
Function code Read Holding Registers (Default) (0)
It defines the function code of standard ModBus used to acquire the registers of density. 04 Read Input Registers (1)
Register number of density
0 99999 45055
It defines the number of the register to read to acquire the density.
Data type of density Integer (32 bit) (0)
It defines the type of data used to represent the density. Float (32bit) (Default) (1)
Double (64 bit) (2)
Offset
It defines the offset applied at the data read by ModBus, the range of minimum and maximum offset
0 99999 0
depend of which compensation table is selected and the correction cannot be grater of +/- 2% of
maximum value of density of compensation table used.
Unit of measure of density acquired No one(Default) (0)
It defines in which unit of measure is acquired the density information, the value acquired is after Kg/m³ (1)
converted in the unit of measure associated at the compensation method, if “No one” value is selected Kg/dm³ (2)
no conversion is done. °API (3)

0.1 Meter 1 0.2 Meter 2


0.1.10 Density acquisition 0.2.10 Density acquisition
0.1.10.3 4-20 mA 0.2.10.3 4-20 mA
0.1.10.3.1 Value of 4 mA 0.2.10.3.1 Value of 4 mA
0.1.10.3.2 Value of 20 mA 0.2.10.3.2 Value of 20 mA
VALUES
DESCRIPTION Protection
Min. Max Default
Value of 4mA
-10,000000 9999,900000 611,16
Product density value when in input there are 4,00 mA.
Value of 20mA
-10,000000 9999,900000 1163,86
Product density value when in input there are 20,00 mA.

Page n°30 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
0.1 Meter 1 0.2 Meter 2
0.1.11 Temperature acquisition 0.2.11 Temperature acquisition
0.1.11.1 Source of acquisition 0.2.11.1 Source of acquisition
0.1.11.1.1 Source of acquisition 0.2.11.1.1 Source of acquisition
0.1.11.1.2 Number of decimals 0.2.11.1.2 Number of decimals
DESCRIPTION VALUES Protection
Source of acquisition No one (Default) (0)
It defines how the temperature of product is acquired. PT100 (1)
ModBus (2)
Input 1 4-20 mA (3)
Input 2 4-20 mA (4)
Number of decimals 2 decimals (0)
It defines the number of decimals of the temperature value 1 decimal (Default) (1)

0.1 Meter 1 0.2 Meter 2


0.1.11 Temperature acquisition 0.2.11 Temperature acquisition
0.1.11.2 ModBus 0.2.11.2 ModBus
0.1.11.2.1 Address 0.2.11.2.1 Address
0.1.11.2.2 Function code 0.2.11.2.2 Function code
0.1.11.2.3 Register number of temperature 0.2.11.2.3 Register number of temperature
0.1.11.2.4 Data type of temperature 0.2.11.2.4 Data type of temperature
0.1.11.2.5 Offset 0.2.11.2.5 Offset
VALUES
DESCRIPTION Protection
Min. Max Default
Address Meter 1 Meter 2
247 247
It defines the address used to communicate with Legally relevant ModBus. 247 246
Function code 03 Read Holding Registers (Default) (0)
It defines the function code of standard ModBus used to acquire the registers of temperature. 04 Read Input Registers (1)
Register number of temperature
45057 99999 45057
It defines the number of the register to read to acquire the temperature.
Data type of temperature Integer (32 bit) (0)
It defines the type of data used to represent the temperature. Float (32bit) (Default) (1)
Double (64 bit) (2)
Offset
0 999 0
It defines the offset applied at the data read by ModBus.

0.1 Meter 1 0.2 Meter 2


0.1.11 Temperature acquisition 0.2.11 Temperature acquisition
0.1.11.3 4-20 mA 0.2.11.3 4-20 mA
0.1.11.3.1 Value of 4 mA 0.2.11.3.1 Value of 4 mA
0.1.11.3.2 Value of 20 mA 0.2.11.3.2 Value of 20 mA
VALUES
DESCRIPTION Protection
Min. Max Default
Value of 4mA
-99 999,9 -50
Value of temperature of product in °C or °F when in input there is 4,00 mA.
Value of 20mA
-99 999,9 245
Value of temperature of product in °C or °F when in input there is 20,00 mA.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°31 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
0.1 Meter 1 0.2 Meter 2
0.1.12 Pressure acquisition 0.2.12 Pressure acquisition
0.1.12.1 Source of acquisition 0.2.12.1 Source of acquisition
0.1.12.1.1 Source of acquisition 0.2.12.1.1 Source of acquisition
0.1.12.1.2 Number of decimals 0.2.12.1.2 Number of decimals
DESCRIPTION VALUES Protection
Source of acquisition No one(Default) (0)
It defines how pressure of product is acquired Parameters (1)
ModBus (2)
Input 1 4-20 mA (3)
Input 2 4-20 mA (4)
Unit of measurement of pressure kPag (Default) (0)
It defines the unit of measurement of pressure Barg (1)
psig (2)

0.1 Meter 1 0.2 Meter 2


0.1.12 Pressure acquisition 0.2.12 Pressure acquisition
0.1.12.2 ModBus 0.2.12.2 ModBus
0.1.12.2.1 Address 0.2.12.2.1 Address
0.1.12.2.2 Function code 0.2.12.2.2 Function code
0.1.12.2.3 Register number of Pressure 0.2.12.2.3 Register number of Pressure
0.1.12.2.4 Data type of Pressure 0.2.12.2.4 Data type of Pressure
0.1.12.2.5 Offset 0.2.12.2.5 Offset
VALUES
DESCRIPTION Protection
Min. Max Default
Address
0 247 0
It defines the address used to communicate with Legally relevant ModBus.
Function code 03 Read Holding Registers (Default) (0)
It defines the function code of standard ModBus used to acquire the registers of pressure. 04 Read Input Registers (1)
Register number of Pressure
0 99999 0
It defines the number of the register to read to acquire the pressure.
Data type of Pressure Integer (32 bit) (0)
It defines the type of data used to represent the pressure. Float (32bit) (Default) (1)
Double (64 bit) (2)
Offset
-9999 999 0
It defines the offset applied at the data read by ModBus.

0.1 Meter 1 0.2 Meter 2


0.1.12 Pressure acquisition 0.2.12 Pressure acquisition
0.1.12.3 4-20 mA 0.2.12.3 4-20 mA
0.1.12.3.1 Value of 4 mA 0.2.12.3.1 Value of 4 mA
0.1.12.3.2 Value of 20 mA 0.2.12.3.2 Value of 20 mA
VALUES
DESCRIPTION Protection
Min. Max Default
Value of 4mA
0 99999 0,00
Product pressure value when in input there are 4,00 mA.
Value of 20mA
0 99999 103.4
Product pressure value when in input there are 20,00 mA.

Page n°32 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1 PRODUCTS

1.1 Meter 1 1.2 Meter 2 1.3 Differential


1.1.1 Products number 1.2.1 Products number 1.3.1 Products number
VALUES
DESCRIPTION Protection
Minimum Maximum Default
Products number
1 3 1
It allows to set the number of products the meter (measuring system) can deliver.

1.1 Meter 1 1.2 Meter 2 1.3 Differential


1.1.2 Units of measurement 1.2.2 Units of measurement 1.3.2 Units of measurement
1.1.2.1 Units of measurement of Gross volume 1.2.2.1 Units of measurement of Gross volume 1.3.2.1 Units of measurement of Gross volume
1.1.2.2 Units of measurement of mass 1.2.2.2 Units of measurement of mass 1.3.2.2 Units of measurement of mass
1.1.2.3 Units of measurement of flow rate 1.2.2.3 Units of measurement of flow rate 1.3.2.3 Units of measurement of flow rate
1.3.2.4 Reference unit of preset
1.3.2.5 Reference unit of flow rate
VALUES
DESCRIPTION Protection
Value Description
Unit of measurement of Gross volume l (0) litres (Default)
m³ (1) Cubic meters
cm³ (2) Cubic centimetres
gal (uk) (3) UK gallons
gal (us) (4) USA gallons
XXXXXXXX (5) Custom unit of measurement
Unit of measurement of mass Kg (0) Kilograms (Default)
lb (1) Pounds
t (2) Tons
g (3) Grams
Unit of measurement of flow rate /min (default) (0) The flow rate will be expressed in unit of measurement for minute
/hour (1) The flow rate will be expressed in unit of measurement for hour
Reference unit of preset Gross volume (0) Volume at the instantaneous temperature
Reference unit used to define what the preset quantity is. Gross standard volume (1) Volume compensated in temperature
Mass (2) Mass of product (Default)
Reference unit of flow rate Gross volume (0) Volume at the instantaneous temperature
Reference unit used to calculate flow rate. Gross standard volume (1) Volume compensated in temperature
Mass (2) Mass of product (Default)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°33 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2 1.3 Differential
1.1.3 Displays 1.2.3 Displays 1.3.3 Displays
1.1.3.1 Configuration of Area 1 1.2.3.1 Configuration of Area 1 1.3.3.1 Configuration of Area 1
1.1.3.2 Configuration of Area 2 1.2.3.2 Configuration of Area 2 1.3.3.2 Configuration of Area 2
1.1.3.3 Configuration of Area 3 1.2.3.3 Configuration of Area 3 1.3.3.3 Configuration of Area 3
1.1.3.4 Configuration of Area 4 1.2.3.4 Configuration of Area 4 1.3.3.4 Configuration of Area 4
DESCRIPTION Value Description Protection
Configuration of Area 1 Gross volume (0)
Data visualized on AREA 1 of the display. Gross standard volume (1)
Mass (Default) (2)
Configuration of Area 2 Gross volume (0)
Data visualized on AREA 2 of the display. Gross standard volume (1)
Mass (2)
Flow rate (default) (3)
Average flow rate (4)
Preset (5)
Preset in decrease (6)
Configuration of Area 3 Gross volume (0)
Data visualized on AREA 3 of the display. Gross standard volume (1)
Mass (2)
Flow rate (3)
Average flow rate (4)
Preset (default Differential) (5)
Preset in decrease (6)
Alpha/Strength (7)
Ave. Alpha/Strength (8)
Base density (9)
Average base density (10)
Observed density (11)
Average observed density (12)
Pressure (13)
Average pressure (14)
Equilibrium pressure (15)
Total gross volume (16)
Total gross standard volume (17)
Total Mass (default Meter1 and Meter 2) (18)
Temperature (19)
Average temperature (20)
Percentage (21)
Configuration of Area 4 No one (default) (0)
Data visualized on AREA 4 of the display. Temperature (1)
Average temperature (2)

Page n°34 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1.1 Meter 1 1.2 Meter 2 1.3 Differential
1.1.3 Displays 1.2.3 Displays 1.3.3 Displays
1.1.3.5 Number of decimals 1.2.3.5 Number of decimals 1.3.3.5 Number of decimals
1.1.3.6 Display of Mass 1.2.3.6 Display of Mass 1.3.3.6 Display of Mass
1.3.3.7 Display of quantity
DESCRIPTION Value Description Protection
Number of decimals 3 decimals (0)
Number of decimals used to visualize all the quantities. 2 decimals (1)
1 decimal (2)
0 decimals (Default) (3)
Display of Mass Disabled (0)
It enables/disables the visualization of the mass quantities. Enabled (default) (1)
Display of quantity Single batch (default) (0)
It allows to set if the quantity visualized (Gross volume, Net volume and Mass) are relative to the
batch or the sum of batches.
Sum of batches (1)

1.1 Meter 1 1.2 Meter 2 1.3 Differential


1.1.4 Product 1 1.2.4 Product 1 1.3.4 Product 1
1.1.4.1 Name 1.2.4.1 Name 1.3.4.1 Name
1.1.5 Product 2 1.2.5 Product 2 1.3.5 Product 2
1.1.5.1 Name 1.2.5.1 Name 1.3.5.1 Name
1.1.6 Product 3 1.2.6 Product 3 1.3.6 Product 3
1.1.6.1 Name 1.2.6.1 Name 1.3.6.1 Name
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum DEFAULT
Name 1.1.4.1 PRODUCT 1 METER 1 0 characters 8 characters LIQUID
It allows to set the name of the product. 1.1.5.1 PRODUCT 2 METER 1 0 characters 8 characters P2 MET.1
1.1.6.1 PRODUCT 3 METER 1 0 characters 8 characters P3 MET.1
1.2.4.1 PRODUCT 1 METER 2 0 characters 8 characters VAPOR
1.2.5.1 PRODUCT 2 METER 2 0 characters 8 characters P2 MET.2
1.2.6.1 PRODUCT 3 METER 2 0 characters 8 characters P3 MET.2
1.3.4.1 DIFFERENTIAL 1 0 characters 8 characters LPG
1.3.5.1 DIFFERENTIAL 2 0 characters 8 characters DIFF.2
1.3.6.1 DIFFERENTIAL 3 0 characters 8 characters DIFF.3

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°35 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.2 Temperature range 1.2.4.2 Temperature range
1.1.4.2.1 Minimum temperature 1.2.4.2.1 Minimum temperature
1.1.4.2.2 Maximum temperature 1.2.4.2.2 Maximum temperature
1.1.5 Product 2 1.2.5 Product 2
1.1.5.2 Temperature range 1.2.5.2 Temperature range
1.1.5.2.1 Minimum temperature 1.2.5.2.1 Minimum temperature
1.1.5.2.2 Maximum temperature 1.2.5.2.2 Maximum temperature
1.1.6 Product 3 1.2.6 Product 3
1.1.6.2 Temperature range 1.2.6.2 Temperature range
1.1.6.2.1 Minimum temperature 1.2.6.2.1 Minimum temperature
1.1.6.2.2 Maximum temperature 1.2.6.2.2 Maximum temperature
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Minimum temperature 1.1.4.2.1 PRODUCT 1 METER 1 -40°C -40°F Par. 1.1.4.2.2 -50°C/ -58°F
1.1.5.2.1 PRODUCT 2 METER 1 -40°C -40°F Par. 1.1.5.2.2 -50°C/-58°F
1.1.6.2.1 PRODUCT 3 METER 1 -40°C -40°F Par. 1.1.6.2.2 -50°C/-58°F
1.2.4.2.1 PRODUCT 1 METER 2 -40°C -40°F Par. 1.2.4.2.2 -50°C/-58°F
1.2.5.2.1 PRODUCT 2 METER 2 -40°C -40°F Par. 1.2.5.2.2 -50°C/-58°F
1.2.6.2.1 PRODUCT 3 METER 2 -40°C -40°F Par. 1.2.6.2.2 -50°C/-58°F
Maximum temperature 1.1.4.2.2 PRODUCT 1 METER 1 Par. 1.1.4.2.1 245°C o 473°F 245°C o 473°F
1.1.5.2.2 PRODUCT 2 METER 1 Par. 1.1.5.2.1 245°C o 473°F 245°C o 473°F
1.1.6.2.2 PRODUCT 3 METER 1 Par. 1.1.6.2.1 245°C o 473°F 245°C o 473°F
1.2.4.2.2 PRODUCT 1 METER 2 Par. 1.2.4.2.1 245°C o 473°F 245°C o 473°F
1.2.5.2.2 PRODUCT 2 METER 2 Par. 1.2.5.2.1 245°C o 473°F 245°C o 473°F
1.2.6.2.2 PRODUCT 3 METER 2 Par. 1.2.6.2.1 245°C o 473°F 245°C o 473°F

Page n°36 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.3 Density range 1.2.4.3 Density range
1.1.5 Product 2 1.2.5 Product 2
1.1.5.3 Density range 1.2.5.3 Density range
1.1.6 Product 3 1.2.6 Product 3
1.1.6.3 Density range 1.2.6.3 Density range
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Alpha/Alcoholic strength 1.1.4.3.1 PRODUCT 1 METER 1 Par. 1.1.4.3.2 Par. 1.1.4.3.3
It allows to set the value of “Alpha” or “Alcoholic strength” 1.1.5.3.1 PRODUCT 2 METER 1 Par. 1.1.5.3.2 Par. 1.1.5.3.3
related to the “Volume thermal conversion” method selected. 1.1.6.3.1 PRODUCT 3 METER 1 Par. 1.1.6.3.2 Par. 1.1.6.3.3 See table of conversion
1.2.4.3.1 PRODUCT 1 METER 2 Par. 1.2.4.3.2 Par. 1.2.4.3.3 methods
1.2.5.3.1 PRODUCT 2 METER 2 Par. 1.2.5.3.2 Par. 1.2.5.3.3
1.2.6.3.1 PRODUCT 3 METER 2 Par. 1.2.6.3.2 Par. 1.2.6.3.3
Alpha/Alcoholic strength (Minimum value) 1.1.4.3.2 PRODUCT 1 METER 1
1.1.5.3.2 PRODUCT 2 METER 1
1.1.6.3.2 PRODUCT 3 METER 1 See table of conversion See table of conversion See table of conversion
1.2.4.3.2 PRODUCT 1 METER 2 methods methods methods
1.2.5.3.2 PRODUCT 2 METER 2
1.2.6.3.2 PRODUCT 3 METER 2
Alpha/Alcoholic strength (Maximum value) 1.1.4.3.3 PRODUCT 1 METER 1
1.1.5.3.3 PRODUCT 2 METER 1
1.1.6.3.3 PRODUCT 3 METER 1 See table of conversion See table of conversion See table of conversion
1.2.4.3.3 PRODUCT 1 METER 2 methods methods methods
1.2.5.3.3 PRODUCT 2 METER 2
1.2.6.3.3 PRODUCT 3 METER 2

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°37 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.3 Density range 1.2.4.3 Density range
1.1.5 Product 2 1.2.5 Product 2
1.1.5.3 Density range 1.2.5.3 Density range
1.1.6 Product 3 1.2.6 Product 3
1.1.6.3 Density range 1.2.6.3 Density range
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Base density 1.1.4.3.4 PRODUCT 1 METER 1 Par. 1.1.4.3.5 Par. 1.1.4.3.6
It allows to set the value of “Base density” related to the 1.1.5.3.4 PRODUCT 2 METER 1 Par. 1.1.5.3.5 Par. 1.1.5.3.6
“Volume thermal conversion” method selected. 1.1.6.3.4 PRODUCT 3 METER 1 Par. 1.1.6.3.5 Par. 1.1.6.3.6 See table of conversion
1.2.4.3.4 PRODUCT 1 METER 2 Par. 1.2.4.3.5 Par. 1.2.4.3.6 methods
1.2.5.3.4 PRODUCT 2 METER 2 Par. 1.2.5.3.5 Par. 1.2.5.3.6
1.2.6.3.4 PRODUCT 3 METER 2 Par. 1.2.6.3.5 Par. 1.2.6.3.6
Base density (Minimum value) 1.1.4.3.5 PRODUCT 1 METER 1
1.1.5.3.5 PRODUCT 2 METER 1
1.1.6.3.5 PRODUCT 3 METER 1 See table of conversion See table of conversion See table of conversion
1.2.4.3.5 PRODUCT 1 METER 2 methods methods methods
1.2.5.3.5 PRODUCT 2 METER 2
1.2.6.3.5 PRODUCT 3 METER 2
Base density (Maximum value) 1.1.4.3.6 PRODUCT 1 METER 1
1.1.5.3.6 PRODUCT 2 METER 1
1.1.6.3.6 PRODUCT 3 METER 1 See table of conversion See table of conversion See table of conversion
1.2.4.3.6 PRODUCT 1 METER 2 methods methods methods
1.2.5.3.6 PRODUCT 2 METER 2
1.2.6.3.6 PRODUCT 3 METER 2

Page n°38 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.3 Density range 1.2.4.3 Density range
1.1.5 Product 2 1.2.5 Product 2
1.1.5.3 Density range 1.2.5.3 Density range
1.1.6 Product 3 1.2.6 Product 3
1.1.6.3 Density range 1.2.6.3 Density range
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Observed density 1.1.4.3.7 PRODUCT 1 METER 1 Par. 1.1.4.3.8 Par. 1.1.4.3.9
It allows to set the value of “Observed density” related to 1.1.5.3.7 PRODUCT 2 METER 1 Par. 1.1.5.3.8 Par. 1.1.5.3.9
the “Volume thermal conversion” method selected. 1.1.6.3.7 PRODUCT 3 METER 1 Par. 1.1.6.3.8 Par. 1.1.6.3.9 See table of conversion
1.2.4.3.7 PRODUCT 1 METER 2 Par. 1.2.4.3.8 Par. 1.2.4.3.9 methods
1.2.5.3.7 PRODUCT 2 METER 2 Par. 1.2.5.3.8 Par. 1.2.5.3.9
1.2.6.3.7 PRODUCT 3 METER 2 Par. 1.2.6.3.8 Par. 1.2.6.3.9
Observed density (Minimum value) 1.1.4.3.8 PRODUCT 1 METER 1
1.1.5.3.8 PRODUCT 2 METER 1
1.1.6.3.8 PRODUCT 3 METER 1 See table of conversion See table of conversion See table of conversion
1.2.4.3.8 PRODUCT 1 METER 2 methods methods methods
1.2.5.3.8 PRODUCT 2 METER 2
1.2.6.3.8 PRODUCT 3 METER 2
Observed density (Maximum value) 1.1.4.3.9 PRODUCT 1 METER 1
1.1.5.3.9 PRODUCT 2 METER 1
1.1.6.3.9 PRODUCT 3 METER 1 See table of conversion See table of conversion See table of conversion
1.2.4.3.9 PRODUCT 1 METER 2 methods methods methods
1.2.5.3.9 PRODUCT 2 METER 2
1.2.6.3.9 PRODUCT 3 METER 2

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°39 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.4 PTB Biofuels coefficients 1.2.4.4 PTB Biofuels coefficients
1.1.5 Product 2 1.2.5 Product 2
1.1.5.4 PTB Biofuels coefficients 1.2.5.4 PTB Biofuels coefficients
1.1.6 Product 3 1.2.6 Product 3
1.1.6.4 PTB Biofuels coefficients 1.2.6.4 PTB Biofuels coefficients
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Coefficient A1 mantissa value 1.1.4.4.1 PRODUCT 1 METER 1
It defines value of the mantissa used with constant A1 with 1.1.5.4.1 PRODUCT 2 METER 1
volume thermal conversion method “PTB BIOFUEL”. 1.1.6.4.1 PRODUCT 3 METER 1
-9,99999 9,99999 -1,2361
1.2.4.4.1 PRODUCT 1 METER 2
1.2.5.4.1 PRODUCT 2 METER 2
1.2.6.4.1 PRODUCT 3 METER 2
DESCRIPTION CODE PRODUCT VALUES
Coefficients A1 exponent value E-01 (0)
It defines value of the exponent used with constant A1 with 1.1.4.4.2 PRODUCT 1 METER 1
E-02 (1)
volume thermal conversion method “PTB BIOFUEL”.
The value of the constant A1 will be: 1.1.5.4.2 PRODUCT 2 METER 1 E-03 (default) (2)
Constant A1 = parameter n° 1.1.4.4.1 * exponent
(parameter n°1.1.4.4.2) 1.1.6.4.2 E-04 (3)
PRODUCT 3 METER 1
E-05 (4)

E-06 (5)
1.2.4.4.2 PRODUCT 1 METER 2
E-07 (6)
E-08 (7)
1.2.5.4.2 PRODUCT 2 METER 2
E-09 (8)

1.2.6.4.2 PRODUCT 3 METER 2 E-10 (9)

Page n°40 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.4 PTB Biofuels coefficients 1.2.4.4 PTB Biofuels coefficients
1.1.5 Product 2 1.2.5 Product 2
1.1.5.4 PTB Biofuels coefficients 1.2.5.4 PTB Biofuels coefficients
1.1.6 Product 3 1.2.6 Product 3
1.1.6.4 PTB Biofuels coefficients 1.2.6.4 PTB Biofuels coefficients
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Coefficient A2 mantissa value 1.1.4.4.3 PRODUCT 1 METER 1
It defines value of the mantissa used with constant A2 with 1.1.5.4.3 PRODUCT 2 METER 1
volume thermal conversion method “PTB BIOFUEL”. 1.1.6.4.3 PRODUCT 3 METER 1
-9,99999 9,99999 -6,7788
1.2.4.4.3 PRODUCT 1 METER 2
1.2.5.4.3 PRODUCT 2 METER 2
1.2.6.4.3 PRODUCT 3 METER 2
DESCRIPTION CODE PRODUCT VALUES
E-01 (0)
1.1.4.4.4 PRODUCT 1 METER 1
E-02 (1)

1.1.5.4.4 PRODUCT 2 METER 1 E-03 (2)

1.1.6.4.4 PRODUCT 3 METER 1 E-04 (3)


Coefficients A2 exponent value
It defines value of the exponent used with constant A2 with
1.2.4.4.4 PRODUCT 1 METER 2
volume thermal conversion method “PTB BIOFUEL”. E-05 (4)
The value of the constant A2 will be:
Constant A2 = parameter n° 1.1.4.4.3 * exponent
1.2.5.4.4 PRODUCT 2 METER 2
(parameter n°1.1.4.4.4) E-06 (5)

E-07(default) (6)
1.2.6.4.4 PRODUCT 3 METER 2
E-08 (7)

E-09 (8)
1.2.6.4.4 PRODUCT 3 METER 2
E-10 (9)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°41 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.4 PTB Biofuels coefficients 1.2.4.4 PTB Biofuels coefficients
1.1.5 Product 2 1.2.5 Product 2
1.1.5.4 PTB Biofuels coefficients 1.2.5.4 PTB Biofuels coefficients
1.1.6 Product 3 1.2.6 Product 3
1.1.6.4 PTB Biofuels coefficients 1.2.6.4 PTB Biofuels coefficients
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Coefficient A3 mantissa value 1.1.4.4.5 PRODUCT 1 METER 1
It defines value of the mantissa used with constant A3 with 1.1.5.4.5 PRODUCT 2 METER 1
volume thermal conversion method “PTB BIOFUEL”. 1.1.6.4.5 PRODUCT 3 METER 1
-9,99999 9,99999 -3,8516
1.2.4.4.5 PRODUCT 1 METER 2
1.2.5.4.5 PRODUCT 2 METER 2
1.2.6.4.5 PRODUCT 3 METER 2
DESCRIPTION CODE PRODUCT VALUES
Coefficients A3 exponent value
It defines value of the exponent used with constant A3 with 1.1.4.4.6 PRODUCT 1 METER 1 E-01 (0)
volume thermal conversion method “PTB BIOFUEL”.
The value of the constant A3 will be: E-02 (1)
Constant A3 = parameter n° 1.1.4.4.5 * exponent 1.1.5.4.6 PRODUCT 2 METER 1
E-03 (2)
(parameter n°1.1.4.4.6)
1.1.6.4.6 PRODUCT 3 METER 1 E-04 (3)

E-05 (4)
1.2.4.4.6 PRODUCT 1 METER 2
E-06 (5)

E-07 (6)
1.2.5.4.6 PRODUCT 2 METER 2
E-08 (7)

E-09 (default) (8)


1.2.6.4.6 PRODUCT 3 METER 2
E-10 (9)

Page n°42 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1.1 Meter 1 1.2 Meter 2 1.3 Differential
1.1.4 Product 1 1.2.4 Product 1 1.3.4 Product 1
1.1.4.5 Totalizers 1.2.4.5 Totalizers 1.3.4.5 Totalizers
1.1.5 Product 2 1.2.5 Product 2 1.3.5 Product 2
1.1.5.5 Totalizers 1.2.5.5 Totalizers 1.3.5.5 Totalizers
1.1.6 Product 3 1.2.6 Product 3 1.3.6 Product 3
1.1.6.5 Totalizers 1.2.6.5 Totalizers 1.3.6.5 Totalizers
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Totalizer of Gross volume 1.1.4.5.1 PRODUCT 1 METER 1 0,000 99999999,999 0,000
It allows to change the value of the Totalizer. 1.1.5.5.1 PRODUCT 2 METER 1 0,000 99999999,999 0,000
1.1.6.5.1 PRODUCT 3 METER 1 0,000 99999999,999 0,000
1.2.4.5.1 PRODUCT 1 METER 2 0,000 99999999,999 0,000
1.2.5.5.1 PRODUCT 2 METER 2 0,000 99999999,999 0,000
1.2.6.5.1 PRODUCT 3 METER 2 0,000 99999999,999 0,000
1.3.4.5.1 PRODUCT 1 DIFFERENTIAL 0,000 99999999,999 0,000
1.3.5.5.1 PRODUCT 2 DIFFERENTIAL 0,000 99999999,999 0,000
1.3.6.5.1 PRODUCT 3 DIFFERENTIAL 0,000 99999999,999 0,000
Totalizer of Gross standard volume 1.1.4.5.2 PRODUCT 1 METER 1 0,000 99999999,999 0,000
It allows to change the value of the Totalizer. 1.1.5.5.2 PRODUCT 2 METER 1 0,000 99999999,999 0,000
1.1.6.5.2 PRODUCT 3 METER 1 0,000 99999999,999 0,000
1.2.4.5.2 PRODUCT 1 METER 2 0,000 99999999,999 0,000
1.2.5.5.2 PRODUCT 2 METER 2 0,000 99999999,999 0,000
1.2.6.5.2 PRODUCT 3 METER 2 0,000 99999999,999 0,000
1.3.4.5.2 PRODUCT 1 DIFFERENTIAL 0,000 99999999,999 0,000
1.3.5.5.2 PRODUCT 2 DIFFERENTIAL 0,000 99999999,999 0,000
1.3.6.5.2 PRODUCT 3 DIFFERENTIAL 0,000 99999999,999 0,000
Totalizer of Mass 1.1.4.5.3 PRODUCT 1 METER 1 0,000 99999999,999 0,000
It allows to change the value of the Totalizer. 1.1.5.5.3 PRODUCT 2 METER 1 0,000 99999999,999 0,000
1.1.6.5.3 PRODUCT 3 METER 1 0,000 99999999,999 0,000
1.2.4.5.3 PRODUCT 1 METER 2 0,000 99999999,999 0,000
1.2.5.5.3 PRODUCT 2 METER 2 0,000 99999999,999 0,000
1.2.6.5.3 PRODUCT 3 METER 2 0,000 99999999,999 0,000
1.3.4.5.3 PRODUCT 1 DIFFERENTIAL 0,000 99999999,999 0,000
1.3.5.5.3 PRODUCT 2 DIFFERENTIAL 0,000 99999999,999 0,000
1.3.6.5.3 PRODUCT 3 DIFFERENTIAL 0,000 99999999,999 0,000

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°43 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.6 Pressure range 1.2.4.6 Pressure range
1.1.5 Product 2 1.2.5 Product 2
1.1.5.6 Pressure range 1.2.5.6 Pressure range
1.1.6 Product 3 1.2.6 Product 3
1.1.6.6 Pressure range 1.2.6.6 Pressure range
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Pressure value 1.1.4.6.1 PRODUCT 1 METER 1 1.1.4.6.2 1.1.4.6.3 0 kPag
1.1.5.6.1 PRODUCT 2 METER 1 1.1.5.6.2 1.1.5.6.3 0 kPag
1.1.6.6.1 PRODUCT 3 METER 1 1.1.6.6.2 1.1.6.6.3 0 kPag
1.2.4.6.1 PRODUCT 1 METER 2 1.2.4.6.2 1.2.4.6.3 0 kPag
1.2.5.6.1 PRODUCT 2 METER 2 1.2.5.6.2 1.2.5.6.3 0 kPag
1.2.6.6.1 PRODUCT 3 METER 2 1.2.6.6.2 1.2.6.6.3 0 kPag
Minimum pressure 1.1.4.6.2 PRODUCT 1 METER 1 0,000 1.1.4.6.3 0 kPag
1.1.5.6.2 PRODUCT 2 METER 1 0,000 1.1.5.6.3 0 kPag
1.1.6.6.2 PRODUCT 3 METER 1 0,000 1.1.6.6.3 0 kPag
1.2.4.6.2 PRODUCT 1 METER 2 0,000 1.2.4.6.3 0 kPag
1.2.5.6.2 PRODUCT 2 METER 2 0,000 1.2.5.6.3 0 kPag
1.2.6.6.2 PRODUCT 3 METER 2 0,000 1.2.6.6.3 0 kPag
Maximum pressure 1.1.4.6.3 PRODUCT 1 METER 1 1.1.4.6.2 10340 kPag
1.1.5.6.3 PRODUCT 2 METER 1 1.1.5.6.2 10340 kPag
It depends on the
1.1.6.6.3 PRODUCT 3 METER 1 1.1.6.6.2 10340 kPag
configuration of the unit
1.2.4.6.3 PRODUCT 1 METER 2 1.2.4.6.2 10340 kPag
of measurement
1.2.5.6.3 PRODUCT 2 METER 2 1.2.5.6.2 10340 kPag
1.2.6.6.3 PRODUCT 3 METER 2 1.2.6.6.2 10340 kPag

Page n°44 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.7 Equilibrium pressure method 1.2.4.7 Equilibrium pressure method
1.1.5 Product 2 1.2.5 Product 2
1.1.5.7 Equilibrium pressure method 1.2.5.7 Equilibrium pressure method
1.1.6 Product 3 1.2.6 Product 3
1.1.6.7 Equilibrium pressure method 1.2.6.7 Equilibrium pressure method
DESCRIPTION CODE PRODUCT VALUES Protection
Pe calculation method 1.1.4.7 PRODUCT 1 METER 1 Fixed value (Default) (0)
It defines methos to calculate Pe (equilibrium pressure), only 1.1.5.7 PRODUCT 2 METER 1 Reserved (1)
for table 54. 1.1.6.7 PRODUCT 3 METER 1 Interpolation (2)
1.2.4.7 PRODUCT 1 METER 2
1.2.5.7 PRODUCT 2 METER 2
1.2.6.7 PRODUCT 3 METER 2

1.1 Meter 1 1.2 Meter 2


1.1.4 Product 1 1.2.4 Product 1
1.1.4.8 Pe fixed value 1.2.4.8 Pe fixed value
1.1.5 Product 2 1.2.5 Product 2
1.1.5.8 Pe fixed value 1.2.5.8 Pe fixed value
1.1.6 Product 3 1.2.6 Product 3
1.1.6.8 Pe fixed value 1.2.6.8 Pe fixed value
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Pe fixed value 1.1.4.8 PRODUCT 1 METER 1 0 1500 0
It defines a fixed value of Pe (equilibrium pressure). 1.1.5.8 PRODUCT 2 METER 1 0 1500 0
1.1.6.8 PRODUCT 3 METER 1 0 1500 0
1.2.4.8 PRODUCT 1 METER 2 0 1500 0
1.2.5.8 PRODUCT 2 METER 2 0 1500 0
1.2.6.8 PRODUCT 3 METER 2 0 1500 0

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°45 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
1.1 Meter 1 1.2 Meter 2
1.1.4 Product 1 1.2.4 Product 1
1.1.4.9 Pe interpolation factor 1.2.4.9 Pe interpolation factor
1.1.5 Product 2 1.2.5 Product 2
1.1.5.9 Pe interpolation factor 1.2.5.9 Pe interpolation factor
1.1.6 Product 3 1.2.6 Product 3
1.1.6.9 Pe interpolation factor 1.2.6.9 Pe interpolation factor
VALUES
DESCRIPTION CODE PRODUCT Protection
Minimum Maximum Default
Pe factor at temperature 1 1.1.4.9.1 PRODUCT 1 METER 1 0 1500 0
It defines equilibrium pressure value at temperature 1. 1.1.5.9.1 PRODUCT 2 METER 1 0 1500 0
1.1.6.9.1 PRODUCT 3 METER 1 0 1500 0
1.2.4.9.1 PRODUCT 1 METER 2 0 1500 0
1.2.5.9.1 PRODUCT 2 METER 2 0 1500 0
1.2.6.9.1 PRODUCT 3 METER 2 0 1500 0
Pe factor at temperature 2 1.1.4.9.2 PRODUCT 1 METER 1 0 1500 0
It defines equilibrium pressure value at temperature 2. 1.1.5.9.2 PRODUCT 2 METER 1 0 1500 0
1.1.6.9.2 PRODUCT 3 METER 1 0 1500 0
1.2.4.9.2 PRODUCT 1 METER 2 0 1500 0
1.2.5.9.2 PRODUCT 2 METER 2 0 1500 0
1.2.6.9.2 PRODUCT 3 METER 2 0 1500 0
Pe factor at temperature 3 1.1.4.9.3 PRODUCT 1 METER 1 0 1500 0
It defines equilibrium pressure value at temperature 3. 1.1.5.9.3 PRODUCT 2 METER 1 0 1500 0
1.1.6.9.3 PRODUCT 3 METER 1 0 1500 0
1.2.4.9.3 PRODUCT 1 METER 2 0 1500 0
1.2.5.9.3 PRODUCT 2 METER 2 0 1500 0
1.2.6.9.3 PRODUCT 3 METER 2 0 1500 0
Temperature of Pe value 1 1.1.4.9.4 PRODUCT 1 METER 1 -50 245 -40
It defines the value 1 of temperature. 1.1.5.9.4 PRODUCT 2 METER 1 -50 245 -40
1.1.6.9.4 PRODUCT 3 METER 1 -50 245 -40
1.2.4.9.4 PRODUCT 1 METER 2 -50 245 -40
1.2.5.9.4 PRODUCT 2 METER 2 -50 245 -40
1.2.6.9.4 PRODUCT 3 METER 2 -50 245 -40
Temperature of Pe value 2 1.1.4.9.5 PRODUCT 1 METER 1 -50 245 15
It defines the value 2 of temperature. 1.1.5.9.5 PRODUCT 2 METER 1 -50 245 15
1.1.6.9.5 PRODUCT 3 METER 1 -50 245 15
1.2.4.9.5 PRODUCT 1 METER 2 -50 245 15
1.2.5.9.5 PRODUCT 2 METER 2 -50 245 15
1.2.6.9.5 PRODUCT 3 METER 2 -50 245 15
Temperature of Pe value 3 1.1.4.9.6 PRODUCT 1 METER 1 -50 245 60
It defines the value 3 of temperature. 1.1.5.9.6 PRODUCT 2 METER 1 -50 245 60
1.1.6.9.6 PRODUCT 3 METER 1 -50 245 60
1.2.4.9.6 PRODUCT 1 METER 2 -50 245 60
1.2.5.9.6 PRODUCT 2 METER 2 -50 245 60
1.2.6.9.6 PRODUCT 3 METER 2 -50 245 60

Page n°46 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
2 VEGA CONFIGURATION

2.1 Date and time


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
2.1.1 Day
1 31 1
It allows to set the day.
2.1.2 Month
It allows to set the month. 1 12 1

2.1.3 Year
2000 2099 2000
It allows to set the year
2.1.4 Hour
00 23 00
It allows to set the hour
2.1.5 Minutes
00 59 00
It allows to set the minutes
2.1.6 Seconds
00 59 00
It allows to set the seconds

2.2 Switch off delay


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
2.2 Switch off delay
It allows to set a delay before VEGA switches off after a main power failure or disconnection. 0s 9999 s 60 s
Warning: during this delay VEGA is powered by the internal battery.

2.3 Optional boards presence


CODE/DESCRIPTION VALUES Protection
2.3.1 Digital I/O board Not present (Default) (0)
It allows to set presence of the “Digital I/O Board”.
Present (1)

2.4 VEGA serial number/position


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
2.4.1 VEGA serial number
0 characters 15 characters VE-000000
It allows to set the serial number of VEGA. The serial number is engraved on the external Atex plate.
2.4.2 VEGA position
It allows to enter an alphanumeric code that identifies the physical position of the meter in the plant. 0 characters 15 characters VEGA POSITION
The “meter position” can be printed on the reports of the deliveries.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°47 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
2.5 Custom unit of measurement
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
2.5.1 Custom unit label
0 characters 8 characters XXXXXXXX
It allows to set a label for the custom unit of measurement.
2.5.2 Factor to correct mass
Multiplicative correction factor used to convert the mass into Kg or lb when the volume is expressed in custom unit.
The value to input should be calculated with the following formula:

“Volume custom unit of measurement ”


Factor value = -------------------------------------------------
0.000001 9.999999 0.001000
“m3”

For example, if VEGA has:


- The custom unit of measurement “dekalitres”;
- The unit of measurement of mass “kg”;
The factor value to be set is (dekalitres / m3) = 0,01.

2.6 Serial addresses


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
2.6.1 Proprietary protocol
1 999 1
Address used to communicate with VEGA (see manual of “Proprietary protocol”).
2.6.2 ModBus protocol
1 255 1
Address used to communicate with VEGA (see manual of “ModBus protocol”).
2.6.3 SPD printing device
0 99 0
Address used to communicate with VEGA (see manual of “SPD-02 - Shared Printing Device”)
2.6.4 Printer ST500-M
1 16 1
Address used to communicate with VEGA (see datasheet of “Printer ST500-M”).
2.6.5 MRD
1 99 1
Address used to communicate with VEGA (see manual of “MRD-Metrical Recording Device”).

2.7 Communication protocol


CODE/DESCRIPTION VALUES Protection
2.7.1 Automation protocol Proprietary protocol (Default) (0)
It allows to set which of the two enabled protocols (ModBus or Proprietary) manages the automation of delivery.
ModBus protocol (1)

2.7.2 ModBus data rounding Enabled (0)


Decimals data of ModBus registers can be rounded as data showed and printed.
Disabled (Default) (1)

Page n°48 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
2.8 Decimal separator character
CODE/DESCRIPTION VALUES Protection
Decimal separator character Point (.) (0)
Character used to separate the decimal part of all numerical data.
Comma (,) (Default) (1)

2.9 Display board


CODE/DESCRIPTION VALUES Protection
2.9.1 Display board model White 1 (0)
Used to perform the automatic correction of display contrast. White 2 (1)
White 3 (Default) (2)
2.9.2 Backlight switch-off Minimum Maximum Default
It allows to set after how many minutes of VEGA inactivity the backlight of display will be switched-off.
0 99 30
Setting “0” the backlight will be always active.

2.10 Inferred measures


CODE/DESCRIPTION VALUES Protection
Inferred measures Not legally relevant(Default) (0)
It defines if inferred quantities are legally relevant or not. Legally relevant (1)

2.11 Speed Can-Bus


CODE/DESCRIPTION VALUES Protection
Speed EM6422 CanBus
50Kbits/s (0)
Set the Can-Bus speed with pulse emitter EM6422 CanBus
125Kbits/s (Default) (1)

2.12 Legally relevant ModBus


CODE/DESCRIPTION VALUES Protection
2.12.1 Type of standard Modicon (Default) (0)
It defines which type of standard ModBus must be used. IDA (1)
2.12.2 Minimum delay between message and next polling Minimum Maximum Default
It allows to define the minimum delay in msec between the reception of a message and the next polling of VEGA. 0 9999 10

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°49 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3 ALARMS

3.1 Meter 1 3.2 Meter 2


3.1.1 Pulses emitter 3.2.1 Pulses emitter
3.1.1.1 Emitter not connected 3.2.1.1 Emitter not connected
3.1.1.1.1 Enable/Disable the alarm 3.2.1.1.1 Enable/Disable the alarm
3.1.1.1.2 Emergency connected with the alarm 3.2.1.1.2 Emergency connected with the alarm
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Disabled (0)
It enables/disables the control of the connection from VEGA to the “pulses emitter”.
ALARM 1.01 “Pulses emitter not connected” for meter 1.
Enabled (Default) (1)
ALARM 2.01 “Pulses emitter not connected” for meter 2.
Emergency connected with the alarm Emergency 1 (Default) (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.1 Pulses emitter 3.2.1 Pulses emitter
3.1.1.2 Channel not connected 3.2.1.2 Channel not connected
3.1.1.2.1 Enable/Disable the alarm 3.2.1.2.1 Enable/Disable the alarm
3.1.1.2.2 Emergency connected with the alarm 3.2.1.2.2 Emergency connected with the alarm
3.1.1.2.3 Filter percentage 3.2.1.2.3 Filter percentage
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
It enables/disables the control of the pulses emitter with two channels based on ISO 6551 level B. Disabled (0)
The control is done only if par. 0.2.1 = Two channels A+B.
- ALARM 1.02 “Channel A not connected” for meter 1
- ALARM 2.02 “Channel A not connected” for meter 2
- ALARM 1.03 “Channel B not connected” for meter 1 Enabled (Default) (1)

- ALARM 2.03 “Channel B not connected” for meter 2


Emergency connected with the alarm Emergency 1 (Default) (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (3)
Filter percentage of alarm Minimum Maximum Default
It allows to set the filter on the spurious pulses. The bigger is the value, the greater is the filtering. 0% 100 % 0%

Page n°50 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter 2
3.1.2 Flow rate 3.2.2 Flow rate
3.1.2.1 Low flow rate 3.2.2.1 Low flow rate
3.1.2.1.1 Enable/Disable the alarm 3.2.2.1.1 Enable/Disable the alarm
3.1.2.1.2 Emergency connected with the alarm 3.2.2.1.2 Emergency connected with the alarm
3.1.2.1.3 Seconds in low flow rate 3.2.2.1.3 Seconds in low flow rate
3.1.2.1.4 Seconds before flow rate check 3.2.2.1.4 Seconds before flow rate check
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the flow rate does not go under the Minimum flow rate.
- ALARM 1.04 “Low Flow rate” for meter 1
Enabled (1)
- ALARM 2.04 “Low Flow rate” for meter 2
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds in low flow rate Minimum Maximum Default
Time during which the Flow rate can stay under the Minimum flow rate value before going in alarm. 0 99 10
Seconds before flow check Minimum Maximum Default
It defines how much time, after the opening of preset valve, the check of minimum flow rate must begin. 0 99 10

3.1 Meter 1 3.2 Meter 2


3.1.2 Flow rate 3.2.2 Flow rate
3.1.2.2 High flow rate 3.2.2.2 High flow rate
3.1.2.2.1 Enable/Disable the alarm 3.2.2.2.1 Enable/Disable the alarm
3.1.2.2.2 Emergency connected with the alarm 3.2.2.2.2 Emergency connected with the alarm
3.1.2.2.3 Seconds in high flow rate 3.2.2.2.3 Seconds in high flow rate
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the flow rate does not go over the Maximum flow rate.
- ALARM 1.05 “High Flow rate” for meter 1
Enabled (1)
- ALARM 2.05 “High Flow rate” for meter 2
Emergency connected with the alarm Emergency 1 (0)
Emergency 2 (Default) (1)
Type of action carried out if the VEGA goes in alarm. Emergency 3 (2)
Info (3)
Seconds in high flow rate Minimum Maximum Default
Time during which the Flow rate can stay over the Maximum flow rate value before going in alarm. 0 99 5

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°51 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter 2
3.1.2 Flow rate 3.2.2 Flow rate
3.1.2.3 Zero flow rate 3.2.2.3 Zero flow rate
3.1.2.3.1 Enable/Disable the alarm 3.2.2.3.1 Enable/Disable the alarm
3.1.2.3.2 Emergency connected with the alarm 3.2.2.3.2 Emergency connected with the alarm
3.1.2.3.3 Seconds in zero flow rate 3.2.2.3.3 Seconds in zero flow rate
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the flow rate does not go to zero during the batch.
- ALARM 1.06 “Zero flow rate” for meter 1
Enabled (1)
- ALARM 2.06 “Zero flow rate” for meter 2
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds in zero flow rate Minimum Maximum Default
Time during which the flow rate can stay at zero before going in alarm. 0 99 10

3.1 Meter 1 3.2 Meter 2


3.1.2 Flow rate 3.2.2 Flow rate
3.1.2.4 Negative flow rate 3.2.2.4 Negative flow rate
3.1.2.4.1 Enable/Disable the alarm 3.2.2.4.1 Enable/Disable the alarm
3.1.2.4.2 Emergency connected with the alarm 3.2.2.4.2 Emergency connected with the alarm
3.1.2.4.3 Seconds in negative flow rate 3.2.2.4.3 Seconds in negative flow rate
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the flow rate does not become negative.
- ALARM 1.07 “Negative flow rate” for meter 1
Enabled (1)
- ALARM 2.07 “Negative flow rate” for meter 2
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds in negative flow rate Minimum Maximum Default
Time during which the flow rate can stay at negative before going in alarm. 0 99 5

Page n°52 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter2
3.1.3 Valves 3.2.3 Valves
3.1.3.1 Block valve not opened 3.2.3.3 Block valve not opened
3.1.3.1.1 Enable/Disable the alarm 3.2.3.3.1 Enable/Disable the alarm
3.1.3.1.2 Emergency connected with the alarm 3.2.3.3.2 Emergency connected with the alarm
3.1.3.1.3 Seconds for valve positioning 3.2.3.3.3 Seconds for valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
It enables/disables the control of opening of the “block valve” opening. Disabled (Default) (0)

The control uses the input signals: Block valve opened and Block valve closed.
- ALARM 1.27 “Block valve not opened” for meter 1. Enabled (1)
- ALARM 2.27 “Block valve not opened” for meter 2.
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds without feedback Minimum Maximum Default
Time after which, starting from valve opening command, VEGA controls the correct position of the feedback signals. 0 99 5

3.1 Meter 1 3.2 Meter2


3.1.3 Valves 3.2.3 Valves
3.1.3.2 Block valve not closed 3.2.3.2 Block valve not closed
3.1.3.2.1 Enable/Disable the alarm 3.2.3.2.1 Enable/Disable the alarm
3.1.3.2.2 Emergency connected with the alarm 3.2.3.2.2 Emergency connected with the alarm
3.1.3.2.3 Seconds for valve positioning 3.2.3.2.3 Seconds for valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
It enables/disables the control of the “block valve” closing. Disabled (Default) (0)

The control uses the input signals: Block valve opened and Block valve closed.
- ALARM 1.28 “Block valve not closed” for meter 1. Enabled (1)
- ALARM 2.28 “Block valve not closed” for meter 2.
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds without feedback Minimum Maximum Default
Time after which, starting from valve closing command, VEGA controls the correct position of the feedback signals. 0 99 5

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°53 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter2
3.1.3 Valves 3.2.3 Valves
3.1.3.3 No flow of product 3.2.3.3 No flow of product
3.1.3.3.1 Enable/Disable the alarm 3.2.3.3.1 Enable/Disable the alarm
3.1.3.3.2 Emergency connected with the alarm 3.2.3.3.2 Emergency connected with the alarm
3.1.3.3.3 Seconds without flow after a start 3.2.3.3.3 Seconds without flow after a start
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that, after the command of preset valve opening, the product flows into the meter.
- ALARM 1.08 “No product flow after start” meter 1.
Enabled (1)
- ALARM 2.08 “No product flow after start” meter 2.
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds without flow after a start Minimum Maximum Default
Time after which, starting from opening command valve, VEGA controls the flow of product. 0 99 10

3.1 Meter 1 3.2 Meter2


3.1.3 Valves 3.2.3 Valves
3.1.3.4 Preset valve not closed 3.2.3.4 Preset valve not closed
3.1.3.4.1 Enable/Disable the alarm 3.2.3.4.1 Enable/Disable the alarm
3.1.3.4.2 Emergency connected with the alarm 3.2.3.4.2 Emergency connected with the alarm
3.1.3.4.3 Seconds with flow after a stop 3.2.3.4.3 Seconds with flow after a stop
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that, after the command of preset valve closing, the product does not flow METER 1
into the meter. Enabled (Default) (1)

- ALARM 1.34 “Preset valve not closed” for meter 1. Disabled (Default) (0)
- ALARM 2.34 “Preset valve not closed” for meter 2. METER 2
- Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds with flow after closure Minimum Maximum Default
Time after which, starting from closing command valve, VEGA controls the flow of product. 0 99 3

Page n°54 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter2
3.1.3 Valves 3.2.3 Valves
3.1.3.5 Selecting valve of Prod.1 3.2.3.5 Selecting valve of Prod.1
3.1.3.5.1 Enable/Disable the alarm 3.2.3.5.1 Enable/Disable the alarm
3.1.3.5.2 Emergency connected with the alarm 3.2.3.5.2 Emergency connected with the alarm
3.1.3.5.3 Seconds of valve positioning 3.2.3.5.3 Seconds of valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Enables the control of right positioning for selecting valve. Disabled (Default) (0)

If the valve is not positioned in the correct way, totally opened or closed, an alarm will be displayed:
- ALARM 1.35 for Product 1 of Meter 1 Enabled (1)
- ALARM 2.35 for Product 1 of Meter 2
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds of valve positioning Minimum Maximum Default
It defines the number of seconds from the command of opening/closing the selecting valve, to generate the alarm. 0 99 5

3.1 Meter 1 3.2 Meter2


3.1.3 Valves 3.2.3 Valves
3.1.3.6 Selecting valve of Prod.2 3.2.3.6 Selecting valve of Prod.2
3.1.3.6.1 Enable/Disable the alarm 3.2.3.6.1 Enable/Disable the alarm
3.1.3.6.2 Emergency connected with the alarm 3.2.3.6.2 Emergency connected with the alarm
3.1.3.6.3 Seconds of valve positioning 3.2.3.6.3 Seconds of valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Enables the control of right positioning for selecting valve. Disabled (Default) (0)

If the valve is not positioned in the correct way, totally opened or closed, an alarm will be displayed:
- ALARM 1.36 for Product 2 of Meter 1 Enabled (1)
- ALARM 2.36 for Product 2 of Meter 2
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds for valve positioning Minimum Maximum Default
It defines the number of seconds from the command of opening/closing the selecting valve, to generate the alarm. 0 99 5

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°55 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter2
3.1.3 Valves 3.2.3 Valves
3.1.3.6 Selecting valve of Prod.3 3.2.3.7 Selecting valve of Prod.3
3.1.3.7.1 Enable/Disable the alarm 3.2.3.7.1 Enable/Disable the alarm
3.1.3.7.2 Emergency connected with the alarm 3.2.3.7.2 Emergency connected with the alarm
3.1.3.7.3 Seconds of valve positioning 3.2.3.7.3 Seconds of valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
Enables the control of right positioning for selecting valve. Disabled (Default) (0)

If the valve is not positioned in the correct way, totally opened or closed, an alarm will be displayed:
- ALARM 1.37 for Product 3 of Meter 1 Enabled (1)
- ALARM 2.37 for Product 3 of Meter 2
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds for valve positioning Minimum Maximum Default
It defines the number of seconds from the command of opening/closing the selecting valve, to generate the alarm. 0 99 5

3.1 Meter 1 3.2 Meter2


3.1.3 Valves 3.2.3 Valves
3.1.3.8 Vapour recovery not opened 3.2.3.8 Vapour recovery not opened
3.1.3.8.1 Enable/Disable the alarm 3.2.3.8.1 Enable/Disable the alarm
3.1.3.8.2 Emergency connected with the alarm 3.2.3.8.2 Emergency connected with the alarm
3.1.3.8.3 Seconds for valve positioning 3.2.3.8.3 Seconds for valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
It enables/disables the control of the “vapour recovery valve” opening. Disabled (Default) (0)

The control uses the input signals: Vapour recovery valve opened and Vapour recovery valve closed
- ALARM 1.25 “Vapour recovery valve not opened” for Meter 1. Enabled (1)
- ALARM 2.25 “Vapour recovery valve not opened” for Meter 2.
Enable/Disable the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds for valve positioning Minimum Maximum Default
Time after which, starting from valve opening command, VEGA controls the correct position of the feedback signals 0 99 5

Page n°56 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter2
3.1.3 Valves 3.2.3 Valves
3.1.3.9 Vapour recovery not closed 3.2.3.9 Vapour recovery not closed
3.1.3.9.1 Enable/Disable the alarm 3.2.3.9.1 Enable/Disable the alarm
3.1.3.9.2 Emergency connected with the alarm 3.2.3.9.2 Emergency connected with the alarm
3.1.3.9.3 Seconds for valve positioning 3.2.3.9.3 Seconds for valve positioning
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
It enables/disables the control of the vapour recovery valve closing. Disabled (Default) (0)

The control uses the input signals: Vapour recovery valve opened and Vapour recovery valve closed
- ALARM 1.26 “Vapour recovery valve not closed” for Meter 1. Enabled (1)
- ALARM 2.26 “Vapour recovery valve not closed” for Meter 2.
Enable/Disable the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds without feedback Minimum Maximum Default
Time after which, starting from valve closing command, VEGA controls the correct position of the feedback signals. 0 99 5

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°57 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter2
3.1.4 PT100 temperature probe 3.2.4 PT100 temperature probe
3.1.4.1 Enable/Disable the alarm 3.2.4.1 Enable/Disable the alarm
3.1.4.2 Emergency connected with the alarm 3.2.4.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the Pt100 temperature probe is connected and works properly. METER 1
Enabled (Default) (1)

- ALARM 1.11 “Pt100 probe not working” for meter 1. Disabled (Default) (0)
- ALARM 2.11 “Pt100 probe not working” for meter 2. METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.1 Minimum product 1 3.2.5.1 Minimum product 1
3.1.5.1.1 Enable/Disable the alarm 3.2.5.1.1 Enable/Disable the alarm
3.1.5.1.2 Emergency connected with the alarm 3.2.5.1.2 Emergency connected with the alarm
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go under the value set in the METER 1
parameter of “Minimum temperature”. Enabled (Default) (1)

- ALARM 1.16 “Low temperature of product 1” for meter 1. Disabled (Default) (0)
- ALARM 2.16 “Low temperature of product 1” for meter 2. METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

Page n°58 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter 2
3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.2 Maximum product 1 3.2.5.2 Maximum product 1
3.1.5.2.1 Enable/Disable the alarm 3.2.5.2.1 Enable/Disable the alarm
3.1.5.2.2 Emergency connected with the alarm 3.2.5.2.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go over the value set in the parameter METER 1
Enabled (Default) (1)
of “Maximum temperature”.
- ALARM 1.17 “High temperature of Product 1” for meter 1. Disabled (Default) (0)
METER 2
- ALARM 2.17 “High temperature of Product 1” for meter 2. Enabled (1)
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.3 Conversion method Prod. 1 3.2.5.3 Conversion method Prod. 1
3.1.5.3.1 Enable/Disable the alarm 3.2.5.3.1 Enable/Disable the alarm
3.1.5.3.2 Emergency connected with the alarm 3.2.5.3.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go outside the limits of the “Volume METER 1
Enabled (Default) (1)
thermal conversion” in use.
- ALARM 1.18 “Temperature of prod. 1 out of conversion method range” for meter 1. Disabled (Default) (0)
METER 2
- ALARM 2.18 “Temperature of prod. 1 out of conversion method range” for meter 2. Enabled (1)
Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.4 Minimum product 2 3.2.5.4 Minimum product 2
3.1.5.4.1 Enable/Disable the alarm 3.2.5.4.1 Enable/Disable the alarm
3.1.5.4.2 Emergency connected with the alarm 3.2.5.4.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go under the value set in the METER 1
parameter of “Minimum temperature”. Enabled (Default) (1)

- ALARM 1.19 “Low temperature of product 2” for meter 1. Disabled (Default) (0)
- ALARM 2.19 “Low temperature of product 2” for meter 2. METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°59 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter 2
3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.5 Maximum product 2 3.2.5.5 Maximum product 2
3.1.5.5.1 Enable/Disable the alarm 3.2.5.5.1 Enable/Disable the alarm
3.1.5.5.2 Emergency connected with the alarm 3.2.5.5.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go over the value set in the METER 1
parameter of “Maximum temperature”. Enabled (Default) (1)

- ALARM 1.20 “High temperature of Product 2” for meter 1. Disabled (Default) (0)
- ALARM 2.20 “High temperature of Product 2” for meter 2. METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.6 Conversion method Prod. 2 3.2.5.6 Conversion method Prod. 2
3.1.5.6.1 Enable/Disable the alarm 3.2.5.6.1 Enable/Disable the alarm
3.1.5.6.2 Emergency connected with the alarm 3.2.5.6.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go outside the limits of the “Volume METER 1
thermal conversion” in use. Enabled (Default) (1)

- ALARM 1.21 “Temperature of prod. 2 out of conversion method range” for meter 1. Disabled (Default) (0)
- ALARM 2.21 “Temperature of prod. 2 out of conversion method range” for meter 2. METER 2
- Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

Page n°60 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter 2
3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.7 Minimum product 3 3.2.5.7 Minimum product 3
3.1.5.7.1 Enable/Disable the alarm 3.2.5.7.1 Enable/Disable the alarm
3.1.5.7.2 Emergency connected with the alarm 3.2.5.7.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go under the value set in the METER 1
parameter of “Minimum temperature”. Enabled (Default) (1)

- ALARM 1.22 “Low temperature of product 3” for meter 1. Disabled (Default) (0)
- ALARM 2.22 “Low temperature of product 3” for meter 2. METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.8 Maximum product 3 3.2.5.8 Maximum product 3
3.1.5.8.1 Enable/Disable the alarm 3.2.5.8.1 Enable/Disable the alarm
3.1.5.8.2 Emergency connected with the alarm 3.2.5.8.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
METER 1
It enables/disables the control that the temperature of product does not go over the value set in the parameter Enabled (Default) (1)
of “Maximum temperature”.
- ALARM 1.23 “High temperature of Product 3” for meter 1. Disabled (Default) (0)
METER 2
ALARM 2.23 “High temperature of Product 3” for meter 2 Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°61 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter 2
3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.9 Conversion method Prod. 3 3.2.5.9 Conversion method Prod. 3
3.1.5.9.1 Enable/Disable the alarm 3.2.5.9.1 Enable/Disable the alarm
3.1.5.9.2 Emergency connected with the alarm 3.2.5.9.2 Emergency connected with the alarm
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the temperature of product does not go outside the limits of the “Volume METER 1
thermal conversion” in use. Enabled (Default) (1)

- ALARM 1.24 “Temperature of prod. 3 out of conversion method range” for meter 1. Disabled (Default) (0)
- ALARM 2.24 “Temperature of prod. 3 out of conversion method range” for meter 2. METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.10 Alarm delay time 3.2.5.10 Alarm delay time
3.1.5.10.1 Seconds before alarm check 3.2.5.10.1 Seconds before alarm check
3.1.5.10.2 Seconds before check on start-up 3.2.5.10.2 Seconds before check on start-up
VALUES Protection
CODE/DESCRIPTION
Minimum Maximum Default
Seconds before alarm check
It defines for how many seconds the temperature of product could stay out of temperature range before VEGA goes in 0 99 0
alarm.
Second before check on start-up
0 99 0
It defines how many seconds after the switching on of VEGA the check of products temperature has to start.

3.1 Meter 1 3.2 Meter 2


3.1.5 Products temperature 3.2.5 Products temperature
3.1.5.11 Wrong calculation CTPL 3.2.5.11 Wrong calculation CTPL
3.1.5.11.1 Enable/Disable the alarm 3.2.5.11.1 Enable/Disable the alarm
3.1.5.11.2 Emergency connected with the alarm 3.2.5.11.2 Emergency connected with the alarm
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm Disabled (Default) (0)
It enables/disables the control that generate an alarm if the calculation of CTPL is not possible.
ALARM 1.72 “Error in CTPL calculation”. Enabled (1)

Emergency connected with the alarm Emergency 1 (See par.3.3.1) (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (See par. 3.3.2) (1)
Emergency 3 (See par. 3.3.3) (2)
Info (See par.3.3.4) (3)

Page n°62 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.1 Meter 1 3.2 Meter 2
3.1.6 Densitometer/Alpha/ Alcoholic Strength 4-20mA 3.2.6 Densitometer/Alpha/ Alcoholic Strength 4-20mA
3.1.6.1 Enable/Disable the alarm 3.2.6.1 Enable/Disable the alarm
3.1.6.2 Emergency connected with the alarm 3.2.6.2 Emergency connected with the alarm
3.1.6.3 Seconds before alarm activation 3.2.6.3 Seconds before alarm activation
3.1.6.4 Alarm check 3.2.6.4 Alarm check
3.1.6.5 Seconds before alarm check on start-up 3.2.6.5 Seconds before alarm check on start-up
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm
It enables/disables the control that the data on INPUT 1 (4÷20mA) does not go outside the range. Disabled (Default) (0)

- ALARM 1.49 “Data on INPUT 1 (4-20mA) out of range” of meter 1.


- ALARM 2.49 “Data on INPUT 1 (4-20mA) out of range” of meter 2. Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds before alarm check Minimum Maximum Default
It defines the number of seconds with density out of range to generate the alarm. 0 99 5
Select when the alarm is checked VALUES
Select when alarm is checked Only with delivery (0)
Always (Default) (1)
Seconds before check on start-up Minimum Maximum Default
0 99 0

3.1 Meter 1 3.2 Meter 2


3.1.7 Pressure out of range 3.2.7 Pressure out of range
3.1.7.1 Enable/Disable the alarm 3.2.7.1 Enable/Disable the alarm
3.1.7.2 Emergency connected with the alarm 3.2.7.2 Emergency connected with the alarm
3.1.7.3 Seconds before alarm activation 3.2.7.3 Seconds before alarm activation
3.1.7.4 Alarm check 3.2.7.4 Alarm check
3.1.7.5 Seconds before alarm check on start-up 3.2.7.5 Seconds before alarm check on start-up
CODE/DESCRIPTION METER VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that the data on INPUT 1 (4÷20mA) does not go outside the range. METER 1
- ALARM 1.48 “Pressure out of range” of meter 1. Enabled (Default) (1)

- ALARM 2.48 “Pressure out of range” of meter 2. Disabled (Default) (0)


METER 2
Enabled (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Seconds before alarm check Minimum Maximum Default
It defines the number of seconds with pressure out of range to generate the alarm. 0 99 5
Select when the alarm is checked VALUES
Select when alarm is checked Only with delivery (0)
Always (Default) (1)
Seconds before check on start-up Minimum Maximum Default
It defines how many seconds after the switching on of VEGA the check of products pressure has to start. 0 99 0

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°63 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.1 Meter 1 3.2 Meter 2
3.1.8 Timeout Modbus (Legally rel.) 3.2.8 Timeout Modbus (Legally rel.)
3.1.8.1 Enable/Disable the alarm 3.2.8.1 Enable/Disable the alarm
3.1.8.2 Emergency connected with the alarm 3.2.8.2 Emergency connected with the alarm
3.1.8.3 Milliseconds without communication 3.2.8.3 Milliseconds without communication
3.1.8.4 Seconds before check on start-up 3.2.8.4 Seconds before check on start-up
CODE/DESCRIPTION VALUES Protection
Enable/Disable the alarm Disabled (0)
It enables/disables the control that VEGA receives a valid message from “Legally ModBus protocol”.
ALARM 0.32 “Timeout with Legally ModBus protocol” Enabled (Default) (1)

Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Milliseconds without communication Minimum Maximum Default
Time in ms within VEGA should receive a valid message. 0 99 250
Seconds before check on start-up Minimum Maximum Default
It defines how many seconds after the switching on of VEGA the check of modbus timeout has to start. 0 99 20

3.3 System 3.3.1 Internal temperature 3.3.1.1 Minimum temperature


CODE/DESCRIPTION VALUES Protection
3.3.1.1.1 Enable/Disable the alarm
Disabled (0)
It enables/disables the control that the internal temperature of VEGA does not go under the value set in the parameter.
ALARM 0.01. “Low internal temperature”.
Enabled (Default) (1)

3.3.1.1.2 Emergency connected with the alarm Emergency 1 (Default) (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (3)
3.3.1.1.3 Minimum internal temperature Minimum Maximum Default
Value of minimum internal temperature. -40°C 10°C -10°C

3.3 System 3.3.1 Internal temperature 3.3.1.2 Maximum temperature


CODE/DESCRIPTION VALUES Protection
3.3.1.2.1 Enable/Disable the alarm
Disabled (0)
It enables/disables the control that the internal temperature of VEGA does not go over the value set in the parameter.
ALARM 0.02 “High internal temperature”.
Enabled (Default) (1)

3.3.1.2.2 Emergency connected with the alarm Emergency 1 (Default) (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (3)
3.3.1.2.3 Maximum internal temperature Minimum Maximum Default
Value of maximum internal temperature. 50°C 99°C 80°C

Page n°64 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.3 System 3.3.2 Internal battery
CODE/DESCRIPTION VALUES Protection
3.3.2.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the internal battery is charged. The internal battery is used to power VEGA when the
main power fails.
Enabled (1)
ALARM 0.07 “Low voltage of internal battery”.
3.3.2.2 Emergency connected with the alarm” Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)

3.3 System 3.3.3 Switch off with flow


CODE/DESCRIPTION VALUES Protection
3.3.3.1 Enable/Disable the alarm Disabled (0)
It enables/disables the control that VEGA switched-off with presence of product flow.
ALARM 0.24 “Switch off with flow of product”. Enabled (Default) (1)

3.3.3.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.4 Remote START locked


CODE/DESCRIPTION VALUES Protection
3.3.4.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the remote START push-button is not locked.
The control uses the signals: Remote start.
Enabled (1)
ALARM 0.60 “Remote START locked”.
3.3.4.2 Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.5 Remote STOP locked


CODE/DESCRIPTION VALUES Protection
3.3.5.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the remote STOP push-button is not locked.
The control uses the signals: Remote stop.
Enabled (1)
ALARM 0.61 “Remote STOP locked”.
3.3.5.2 Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°65 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.3 System 3.3.6 Products selector 3.3.6.1 No product selected
CODE/DESCRIPTION VALUES Protection
3.3.6.1.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that at least one product is selected by the product selector.
ALARM 0.35 “No product selected”.
Enabled (1)

3.3.6.1.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.6 Products selector 3.3.6.2 Product selector error


CODE/DESCRIPTION VALUES Protection
3.3.6.2.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that verifies if more than one product is selected by the product selector.
ALARM 0.36 “More products selected”.
Enabled (1)

3.3.6.2.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.7 Input 4-20mA 3.3.7.1 Input 1 4-20mA


CODE/DESCRIPTION VALUES Protection
3.3.7.1.1 Enable/Disable the alarm Disabled (0)
It enables/disables the control that the INPUT 1 (4÷20mA) is inside the range 4÷20mA.
ALARM 0.62 “INPUT 1 (4-20mA) out of range”. Enabled (Default) (1)

3.3.7.1.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.7 Input 4-20mA 3.3.7.2 Input 2 4-20mA


CODE/DESCRIPTION VALUES Protection
3.3.7.2.1 Enable/Disable the alarm Disabled (0)
It enables/disables the control that the INPUT 2 (4÷20mA) is inside the range 4÷20mA.
ALARM 0.63 “Input 2 4-20mA out of range”. Enabled (Default) (1)

3.3.7.2.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

Page n°66 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.3 System 3.3.8 Additives 3.3.8.1 No additive
CODE/DESCRIPTION VALUES Protection
3.3.8.1.1 Enable/Disable the alarm
It enables/disables the control that the additive starts to flow inside the additive meter when the injection valve is opened. Disabled (Default) (0)
ALARM 0.50 “No flow of additive”

Enabled (1)

3.3.8.1.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.8 Additives 3.3.8.2 Additive under treatment


CODE/DESCRIPTION VALUES Protection
3.3.8.2.1 Enable/Disable the alarm
It enables/disables the control that the additive system has the time to inject the additive quantity programmed. Disabled (Default) (0)

The alarm is notified when the previous injection is still active and a new injection should be performed.
ALARM 0.51 “Under treatment of additive”. Enabled (1)

3.3.8.2.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.8 Additives 3.3.8.3 Additive overtreatment


CODE/DESCRIPTION VALUES Protection
3.3.8.3.1 Enable/Disable the alarm
It enables/disables the control that one injection of additive does not give too much additive. Disabled (Default) (0)

ALARM 0.52 “Overtreatment of additive”.


Enabled (1)

3.3.8.3.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°67 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.3 System 3.3.8 Additives 3.3.8.4 Additive Leak
CODE/DESCRIPTION VALUES Protection
3.3.8.4.1 Enable/Disable the alarm
It enables/disables the control that there is not presence of additive flow outside a delivery (Injection valve closed). ALARM Disabled (Default) (0)

0.53 “Additive leak”.


Enabled (1)

3.3.8.4.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

3.3 System 3.3.8 Additives 3.3.8.5 Additive final tolerance


CODE/DESCRIPTION VALUES Protection
3.3.8.5.1 Enable/Disable the alarm
It enables/disables the control that at the end of delivery the injected additive quantities are inside the tolerance specified Disabled (Default) (0)

on parameter.
ALARM 0.55 “Additive X out of tolerance”. Enabled (1)

3.3.8.5.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

Page n°68 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.3 System 3.3.9 Additivators by signals 3.3.9.1 Additivation system 1
CODE/DESCRIPTION VALUES Protection
3.3.9.1.1 Enable/Disable the alarm
It enables/disables the control of the input signal “Additivation system 1 not ready”. Disabled (Default) (0)

ALARM 0.37 “Additivation system 1 not ready”.


Enabled (1)

3.3.9.1.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
3.3.9.1.3 Delay after start Minimum Maximum Default
Delay time, from the delivery start, before checking the correct position of the input additivation system 1 not ready. 0 999 0

3.3 System 3.3.9 Additivators by signals 3.3.9.2 Additivation system 2


CODE/DESCRIPTION VALUES Protection
3.3.9.2.1 Enable/Disable the alarm
It enables/disables the control of the input signal “Additivation system 2 not ready”. Disabled (Default) (0)

ALARM 0.38 “Additivation system 2 not ready”.


Enabled (1)

3.3.9.2.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
3.3.9.2.3 Delay after start Minimum Maximum Default
Delay time, from the delivery start, before checking the correct position of the input additivation system 2 not ready. 0 999 0

3.3 System 3.3.10 Serial lines timeout 3.3.10.1 Proprietary protocol


CODE/DESCRIPTION VALUES Protection
3.3.10.1.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that VEGA receives a valid message within the time programmed in the parameter.
ALARM 0.14 “Timeout with Proprietary protocol”.
Enabled (1)

3.3.10.1.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)
3.3.10.1.3 Seconds without communication Minimum Maximum Default
Time within VEGA should receive a valid message. 0 99 20
3.3.10.1.4 Timeout control in local mode Disabled (Default) (0)
It enables/disables the control also in Local mode. Enabled (1)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°69 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.3 System 3.3.10 Serial lines timeout 3.3.10.2 ModBus protocol
CODE/DESCRIPTION VALUES Protection
3.3.10.2.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that VEGA receives a valid message within the time programmed in the parameter.
ALARM 0.17 “Timeout with ModBus protocol”.
Enabled (1)

3.3.10.2.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)
3.3.10.2.3 Seconds without communication Minimum Maximum Default
Time within VEGA should receive a valid message. 0 99 20
3.3.10.2.4 Timeout control in local mode Disabled (Default) (0)
It enables/disables the control also in Local mode. Enabled (1)

3.3 System 3.3.10 Serial lines timeout 3.3.10.3 SPD printing device
CODE/DESCRIPTION VALUES Protection
3.3.10.3.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that VEGA receives a valid message from the SPD within the time programmed in the
parameter.
Enabled (1)
ALARM 0.20 “Timeout with SPD (Shared Printing Device)”.
3.3.10.3.2 Emergency connected with the alarm Emergency 1 (0)
Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)
3.3.10.3.3 Seconds without communication Minimum Maximum Default
Time within VEGA should receive a valid message from SPD. 0 99 20

3.3 System 3.3.10 Serial lines timeout 3.3.10.4 Printer ST500-M


CODE/DESCRIPTION VALUES Protection
3.3.10.4.1 Enable/Disable the alarm
Disabled (0)
It enables/disables the control that VEGA receives a valid message within the time programmed in the parameter.
ALARM 0.23 “Timeout with printer ST500-M”.
Enabled (Default) (1)

3.3.10.4.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)
3.5.11.4.3 Seconds without communication Minimum Maximum Default
Time within VEGA should receive a valid message. 0 99 20

Page n°70 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.3 System 33.10 Timeouts management 3.3.10.5 MRD
CODE/DESCRIPTION VALUES Protection
3.3.10.5.1 Enable/Disable the alarm
Disabled (0)
It enables/disables the control that VEGA receives a valid message within the time programmed in the parameter.
ALARM 0.28 “Timeout with MRD”.
Enabled (Default) (1)

3.3.10.5.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)
3.3.10.5.3 Seconds without communication Minimum Maximum Default
Time within VEGA should receive a valid message. 0 99 20

3.3 System 3.3.10 Timeouts management 3.3.10.6 Timeout LFD-6 1


CODE/DESCRIPTION VALUES Protection
3.3.10.6.1 Enable/Disable the alarm Disabled (Default) (0)
It enables/disables the control that VEGA receives a valid message within from LFD-6 1.
ALARM 0.68 “Timeout with LFD-6” Enabled (1)

3.3.10.6.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)

3.3 System 3.3.10 Timeouts management 3.3.10.7 Timeout LFD-6 2


CODE/DESCRIPTION VALUES Protection
3.3.10.7.1 Enable/Disable the alarm Disabled (Default) (0)
It enables/disables the control that VEGA receives a valid message within from LFD-6 2.
ALARM 0.87 “Timeout with LFD-6” Enabled (1)

3.3.10.7.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (1)
Emergency 3 (2)
Info (Default) (3)

3.3 System 3.3.11 Product leak


CODE/DESCRIPTION VALUES Protection
3.3.11.1 Enable/Disable the alarm
Disabled (0)
Enable control that if there is flow of product after closing of preset valve VEGAII goes in alarm.
ALARM 0.66 “Product leak”.
Enabled (Default) (1)

3.3.11.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
3.3.11.3 Meter 1 quantity to generate alarm Minimum Maximum Default
Quantity of product that must be delivered on meter 1 after the closing of preset valve for generating alarm. 0 1000,000 3,000
3.3.11.4 Meter 2 quantity to generate alarm Minimum Maximum Default
Quantity of product that must be delivered on meter 2 after the closing of preset valve for generating alarm. 0 1000,000 3,000

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°71 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.3 System 3.3.12 High flow rate too low
CODE/DESCRIPTION VALUES Protection
3.3.12.1 Enable/Disable the alarm
Disabled (Default) (0)
It enables/disables the control that the flow rate does not go under the value specified.
ALARM 0.71 “Flow rate in high flow too low”
Enabled (1)

3.3.12.2 Emergency connected with the alarm Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)
Minimum Maximum Default
3.3.12.3 High flow rate value to control
260 999999 1800
Value of flow rate during high flow rate phase under which start control of alarm.
3.3.12.4 Seconds before start control
0 99 10
It defines after how many seconds from high flow rate phase has to start control of alarm.
3.3.12.5 Seconds under flow rate for alarm
0 99 5
It defines after how many seconds with flow rate under value set in parameter 3.5.13.3 alarm will be generated.

3.3 System 3.3.13 Keyboard


CODE/DESCRIPTION VALUES Protection
3.3.13.1 Enabling
Disabled (0)
Enable control that keyboard communicate with CPU board of VEGA.
ALARM 0.13 “VEGA keyboard broken”.
Enabled (Default) (1)

3.3.13.2 Emergency Emergency 1 (0)


Type of action carried out if the VEGA goes in alarm. Emergency 2 (Default) (1)
Emergency 3 (2)
Info (3)

Page n°72 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
3.4 Emergency functions 3.4.1 Emergency 1
CODE/DESCRIPTION VALUES Protection
3.4.1.1 Preset valve closing Disabled (0)
It enables/disables the closure of the preset valve when the emergency is activated. Enabled (Default) (1)
3.4.1.2 Selecting valve closing Disabled (0)
It enables/disables the closure of the selector valve when the emergency is activated. Enabled (Default) (1)
3.4.1.3 Block valve closing Disabled (0)
It enables/disables the closure of the block valve when the emergency is activated. Enabled (Default) (1)
3.4.1.4 Product pump switching off Disabled (0)
It enables/disables the switching off of the product pump when the emergency is activated. Enabled (Default) (1)
3.4.1.5 Alarm output disabling Disabled (0)
It enables/disables the alarm output when the emergency is activated. Enabled (Default) (1)
3.4.1.6 Stop of pulses counting Disabled(Default) (0)
It enables/disables the pulses counting when the emergency is activated. Enabled (1)
3.4.1.7 Output activated (number)
Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated.
By setting the value ‘0’ no output will be activated. 0 32 0

3.4 Emergency functions 3.4.2 Emergency 2


CODE/DESCRIPTION VALUES Protection
3.4.2.1 Preset valve closing Disabled (0)
It enables/disables the closure of the preset valve when the emergency is activated. Enabled (Default) (1)
3.4.2.2 Selecting valve closing Disabled (0)
It enables/disables the closure of the selector valve when the emergency is activated. Enabled (Default) (1)
3.4.2.3 Block valve closing Disabled(Default) (0)
It enables/disables the closure of the block valve when the emergency is activated. Enabled (1)
3.4.2.4 Product pump switching off Disabled (0)
It enables/disables the switching off of the product pump when the emergency is activated. Enabled (Default) (1)
3.4.2.5 Alarm output disabling Disabled (0)
It enables/disables the alarm output when the emergency is activated. Enabled (Default) (1)
3.4.2.6 Stop of pulses counting Disabled(Default) (0)
It enables/disables the pulses counting when the emergency is activated. Enabled (1)
3.4.2.7 Output activated (number)
Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated.
By setting the value ‘0’ no output will be activated. 0 32 0

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°73 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
3.4 Emergency functions 3.4.3 Emergency 3
CODE/DESCRIPTION VALUES Protection
3.4.3.1 Preset valve closing Disabled (0)
It enables/disables the closure of the preset valve when the emergency is activated. Enabled (Default) (1)
3.4.3.2 Selecting valve closing Disabled(Default) (0)
It enables/disables the closure of the selector valve when the emergency is activated. Enabled (1)
3.4.3.3 Block valve closing Disabled(Default) (0)
It enables/disables the closure of the block valve when the emergency is activated. Enabled (1)
3.4.3.4 Product pump switching off Disabled(Default) (0)
It enables/disables the switching off of the product pump when the emergency is activated. Enabled (1)
3.4.3.5 Alarm output disabling Disabled (0)
It enables/disables the alarm output when the emergency is activated. Enabled (Default) (1)
3.4.3.6 Stop of pulses counting Disabled(Default) (0)
It enables/disables the pulses counting when the emergency is activated. Enabled (1)
3.4.3.7 Output activated (number)
Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated.
By setting the value ‘0’ no output will be activated. 0 32 0

3.4 Emergency functions 3.4.4 Info


CODE/DESCRIPTION VALUES Protection
3.4.4.1 Output activated (number)
Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated.
By setting the value ‘0’ no output will be activated. 0 32 0

NOT PROGRAMMABLE EMERGENCY


EMERGENCY 4 EMERGENCY 5
The preset is closed The preset is closed
The selection valve is closed The selection valve is closed
The block valve is closed The block valve is closed
The product pump is switched off The product pump is switched off
The alarm output is deactivated The alarm output is deactivated
The counting of pulses is deactivated The counting of pulses remains active

Page n°74 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
SYSTEM ALARM TABLE
PARAMETERS
CODE Description that VEGA displays Description
ENABLING EMERGENCY
0.01 Low internal temperature The internal temperature is lower than the value set in the parameter 3.2.1.1.3 3.3.1.1.1 3.3.1.1.2
0.02 High internal temperature The internal temperature is higher than the value set in the parameter 3.2.1.2.3 3.3.1.2.1 3.3.1.2.2
0.03 Executable program altered The executable program memorized in FLASH EPROM MEMORY is altered. Always enabled EMERGENCY4
0.04 Internal clock broken The internal clock does not work. Always enabled EMERGENCY5
0.05 Push-button broken “XXX” The push-button is always active. Always enabled EMERGENCY5
0.06 Display broken The display controller reports a malfunction. Always enabled EMERGENCY5
The internal battery, used to power VEGA when main power fails, is not charged or is
0.07 Low voltage of internal battery 3.3.2.1 3.3.2.2
disconnected.
0.08 Values of parameters saved in FLASH altered The values of the parameters memorized inside the FLASH EPROM MEMORY are altered. Always enabled EMERGENCY4
0.09 Values of parameters saved in RAM altered The values of the parameters memorized inside the RAM MEMORY are altered. Always enabled EMERGENCY4
0.10 Low power supply voltage The main power of VEGA is lower than the minimum value. Always enabled EMERGENCY4
0.11 Archive of legally measurements data is altered The archive of legally measurements data is altered. Always enabled EMERGENCY5
0.13 Keyboard broken The internal board is broken. 3.3.13.1 3.3.13.2
VEGA does not receive a valid message from the serial line programmed has to use the
0.14 Timeout with proprietary protocol 3.3.10.1.1 3.3.10.1.2
proprietary protocol.
0.15 System error Please contact the technical customer service at ISOIL IMPIANTI Spa. Always enabled EMERGENCY4
0.16 Analog I/O board broken The “Analog I/O board” is present by does not work. Always enabled EMERGENCY4
VEGA does not receive a valid message from the serial line programmed to use the ModBus
0.17 Timeout with ModBus protocol 3.3.10.2.1 3.3.10.2.2
protocol.
0.18 Thermal conversion enabled but analog I/O board not present. Thermal conversion enabled but the analog I/O board probe is programmed as not present. Always enabled EMERGENCY4
0.20 Timeout with SPD (Shared Printing Device) VEGA does not receive a valid message from the SPD (Shared Printing Device) 3.3.10.3.1 3.3.10.3.2
0.23 Timeout with printer ST500-M VEGA does not receive a valid message from the printer ST500-M. 3.3.10.4.1 3.3.10.4.2
0.24 Switch off with flow of product VEGA is switched off with presence of product flow. 3.3.3.1 3.3.3.2
0.28 Timeout with MRD (Memory Recording Device) VEGA does not receive a valid message from the MRD (Metrical Recording Device). 3.3.10.5.1 3.3.10.5.2
0.33 Timeout with printer ST500-A/B VEGA does not receive a valid message from the printer ST500-A/B. Always enabled (*) EMERGENCY5
0.35 No product selected by selector The external product selector does not give a signal to select one product. 3.3.6.1.1 3.3.6.1.2
0.36 More products selected by selector The external product selector gives more than one signal of product selection. 3.3.6.2.1 3.3.6.2.2
The delivery of the main product is started but the signal “additivation system 1 not ready” is
0.37 Additivation system 1 not ready 3.3.9.1.1 3.3.9.1.2
active.
The delivery of the main product is started but the signal “additivation system 2 not ready” is
0.38 Additivation system 2 not ready 3.3.9.2.1 3.3.9.2.2
active.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°75 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
SYSTEM ALARM TABLE
PARAMETERS
CODE Description that VEGA displays Description
ENABLING EMERGENCY
0.41 FlexiMix on alarm The FlexiMix is on alarm condition Always active (**) EMERGENCY5
0.42 FlexiMix not ready The FlexiMix is not ready to additize Always active (**) EMERGENCY5
0.43 Interlock from FlexiMix. The FlexiMix cannot additize because has one interlock missing Always active (**) EMERGENCY5
0.44 Configuration alarm of FlexiMix The FlexiMix is not programmed correctly. Always active (**) EMERGENCY5
0.46 Timeout with FlexiMix VEGA does not receive a valid message from the FlexiMix Always active (**) EMERGENCY5
0.50 No flow of additive The injection was activated but the additive did not flow inside the additive meter. 3.3.8.1.1(***) 3.3.8.1.2
0.51 Under treatment of additive The previous injection was still active when a new injection should be started. 3.3.8.2.1(***) 3.3.8.2.2
0.52 Overtreatment of additive The single injection quantity is too low. 3.3.8.3.1(***) 3.3.8.3.2
0.53 Additive leak. The additive flows inside the additive meter also if the injection valve is driven to be closed. 3.3.8.4.1(***) 3.3.8.4.2
0.55 Additive out of tolerance The final quantity of additive is out of the tolerance programmed. 3.3.8.5.1(***) 3.3.8.5.2
0.60 Remote start button locked The external push-button of START is always active. 3.3.4.1 3.3.4.2
0.61 Remote stop button locked The external push-button of STOP is always active. 3.3.5.1 3.3.5.2
0.62 INPUT 1 (4-20mA) is out of limits The value acquired by 4-20mA is out of the It defines limits 3.3.7.1.1 3.3.7.1.2
0.63 INPUT 2 (4-20mA) is out of limits The value acquired by 4-20mA is out of the It defines limits 3.3.7.2.1 3.3.7.2.2
0.66 Product leak The product flows with the valves closed. 3.3.11.1 3.3.11.2
0.68 Timeout with LFD-6 VEGA does not receive a valid message from the display LFD-6 1. 3.3.10.6.1 3.3.10.6.2
0.70 Printer error Parity error or memory full of printer ST500M. Always enabled EMERGENCY5
0.71 Flow rate in high flow too low. Arm flow rate during high flow phase under value set by parameter. 3.3.12.1 3.3.13.2
0.78 Memory full Vega stored the maximum number of legally relevant measurements. Always enabled EMERGENCY5
0.87 Timeout with LFD-6 VEGA does not receive a valid message from the display LFD-6 2. 3.3.10.7.1 3.3.10.7.2
* Note:
** Note: The alarm is checked only if VEGA is associated with FlexiMix by serial communication line.
*** Note: Inside the display “alarm description” and inside the serial communication protocols “additive status” is specified for which additive the alarm was generated.

Page n°76 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
METER 1 ALARM TABLE
Parameters
CODE Description that VEGA displays Description
ENABLING EMERGENCY
1.01 Pulses emitter not connected The pulse emitter is not connected 3.1.1.1.1 3.1.1.1.2
1.02 Channel A of pulses emitter not connected The number of pulses received on channel A is lower than the number received on channel B. 3.1.1.2.1 3.1.1.2.2
1.03 Channel B of pulses emitter not connected The number of pulses received on channel B is lower than the number received on channel A. 3.1.1.2.1 3.1.1.2.2
1.04 Low flow of product The product flow rate is lower than the minimum flow rate. 3.1.2.1.1 3.1.2.1.2
1.05 High flow of product The product flow rate is higher than the maximum flow rate. 3.1.2.2.1 3.1.2.2.2
1.06 Zero flow of product The product flow-rate is zero but the preset valve is open. 3.1.2.3.1 3.1.2.3.2
1.07 Negative flow rate The product flow-rate is negative. 3.1.2.4.1 3.1.2.4.2
1.08 No flow of product after start The product does not flow with the valves opened and the pump switched on. 3.1.2.5.1 3.1.2.5.2
The signal present on the analog input where the Pt100 is connected is not correct or out of
1.11 Pt100 probe not working 3.1.4.1 3.1.4.2
range.
1.16 Low temperature product 1 The temperature of the Product 1 is lower than the minimum value programmed into par. 1.2.1.1. 3.1.5.1.1 3.1.5.1.2
The temperature of the Product 1 is higher than the maximum value programmed into par.
1.17 High temperature product 1 3.1.5.2.1 3.1.5.2.2
1.2.1.2.
1.18 Temperature of prod.1 out of conversion method range The temperature of the Product 1 is out of range of the thermal conversion method in use. 3.1.5.3.1 3.1.5.3.2
The temperature of the Product 2 is higher than the maximum value programmed into par.
1.19 Low temperature product 2 3.1.5.4.1 3.1.5.4.2
1.3.1.2.
1.20 High temperature product 2 The temperature of the Product 2 is lower than the minimum value programmed into par. 1.3.1.1. 3.1.5.5.1 3.1.5.5.2
1.21 Temperature of prod.2 out of conversion method range The temperature of the Product 2 is out of range of the thermal conversion method in use. 3.1.5.6.1 3.1.5.6.2
1.22 Low temperature product 3 The temperature of the Product 3 is lower than the minimum value programmed into par. 1.4.1.1. 3.1.5.7.1 3.1.5.7.2
The temperature of the Product 3 is higher than the maximum value programmed into par.
1.23 High temperature product 3 3.1.5.8.1 3.1.5.8.2
1.4.1.2.
1.24 Temperature of prod.3 out of conversion method range The temperature of the Product 3 is out of range of the thermal conversion method in use. 3.1.5.9.1 3.1.5.9.2
The input signal feedback “vapour recovery valve opened” is not coherent with the command of
1.25 Vapour recovery valve not opened 3.3.4.1.1 3.3.4.1.2
valve of meter 1.
The input signal feedback “vapour recovery valve closed” is not coherent with the command of
1.26 Vapour recovery valve not closed 3.3.4.2.1 3.3.4.2.2
valve of meter 1.
1.27 Block valve not opened The input signal feedback “block valve opened” is not coherent with the command of valve. 3.1.3.1.1 3.1.3.1.2
1.28 Block valve not closed The input signal feedback “block valve closed” is not coherent with the command of valve. 3.1.3.2.1 3.1.3.2.2
1.30 Thermal conversion enabled but temperature, density or pressure not present. Thermal conversion enabled but temperature or density or pressure not acquired. Always enabled EMERGENCY5
1.34 Preset valve not closed. Product flow after a command of closure to preset valve. 3.1.3.4.1 3.1.3.4.2
1.35 Product 1 selecting valve not rightly positioned. Selecting valve not completely closed/opened 3.3.1.1 3.3.1.2
1.36 Product 2 selecting valve not rightly positioned. Selecting valve not completely closed/opened 3.3.2.1 3.3.2.2
1.37 Product 3 selecting valve not rightly positioned. Selecting valve not completely closed/opened 3.3.3.1 3.3.3.2
1.48 Pressure out of range The pressure is out of the established range 3.1.7.1 3.1.7.2
1.49 Density/Alpha or Strength acquired with 4÷20mA is out of range The density or the Alcoholic strength acquired by 4÷20mA signal is out of range. 3.1.6.1 3.1.6.2
1.72 Error in CTPL calculation It’s no possible calculate the CTPL value 3.1.5.11.1 3.1.5.11.2
1.81 Encoder error. Error of magnet of encoder Can-Bus.
Always active if par.
1.82 Encoder error. Wrong pulses sequence on encoder Can-Bus.
n°0.1.2.1 is set to 3.1.1.1.2
1.83 Encoder error. Software reset of encoder Can-Bus.
“ENCODER CAN-BUS”
1.84 Encoder error. Hardware reset of encoder Can-Bus.
1.87 Wrong counting of product. There was a problem in the counting of product. Always enabled EMERGENCY5
VEGA does not receive a valid message from the serial line programmed to use the Legally
1.91 Timeout legally relevant Modbus protocol 3.1.8.1 3.1.8.2
Modbus protocol.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°77 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
METER 2 ALARM TABLE
Parameters
CODE Description that VEGA displays Description
ENABLING EMERGENCY
2.01 Pulses emitter not connected The pulse emitter is not connected 3.2.1.1.1 3.2.1.1.2
2.02 Channel A of pulses emitter not connected The number of pulses received on channel A is lower than the number received on channel B. 3.2.1.2.1 3.2.1.2.2
2.03 Channel B of pulses emitter not connected The number of pulses received on channel B is lower than the number received on channel A. 3.2.1.2.1 3.2.1.2.2
2.04 Low flow of product The product flow rate is lower than the minimum flow rate. 3.2.2.1.1 3.2.2.1.2
2.05 High flow of product The product flow rate is higher than the maximum flow rate. 3.2.2.2.1 3.2.2.2.2
2.06 Zero flow of product The product flow-rate is zero but the preset valve is open. 3.2.2.3.1 3.2.2.3.2
2.07 Negative flow rate The product flow-rate is negative. 3.2.2.4.1 3.2.2.4.2
2.08 No flow of product after start The product does not flow with the valves opened and the pump switched on. 3.2.2.5.1 3.2.2.5.2
The signal present on the analog input where the Pt100 is connected is not correct or out of
2.11 Pt100 probe not working 3.2.4.1 3.2.4.2
range.
2.16 Low temperature product 1 The temperature of the Product 1 is lower than the minimum value programmed into par. 1.2.1.1. 3.2.5.1.1 3.2.5.1.2
The temperature of the Product 1 is higher than the maximum value programmed into par.
2.17 High temperature product 1 3.2.5.2.1 3.2.5.2.2
1.2.1.2.
2.18 Temperature of prod.1 out of conversion method range The temperature of the Product 1 is out of range of the thermal conversion method in use. 3.2.5.3.1 3.2.5.3.2
The temperature of the Product 2 is higher than the maximum value programmed into par.
2.19 Low temperature product 2 3.2.5.4.1 3.2.5.4.2
1.3.1.2.
2.20 High temperature product 2 The temperature of the Product 2 is lower than the minimum value programmed into par. 1.3.1.1. 3.2.5.5.1 3.2.5.5.2
2.21 Temperature of prod.2 out of conversion method range The temperature of the Product 2 is out of range of the thermal conversion method in use. 3.2.5.6.1 3.2.5.6.2
2.22 Low temperature product 3 The temperature of the Product 3 is lower than the minimum value programmed into par. 1.4.1.1. 3.2.5.7.1 3.2.5.7.2
The temperature of the Product 3 is higher than the maximum value programmed into par.
2.23 High temperature product 3 3.2.5.8.1 3.2.5.8.2
1.4.1.2.
2.24 Temperature of prod.3 out of conversion method range The temperature of the Product 3 is out of range of the thermal conversion method in use. 3.2.5.9.1 3.2.5.9.2
The input signal feedback “vapour recovery valve opened” is not coherent with the command of
2.25 Vapour recovery valve not opened 3.4.4.1.1 3.4.4.1.2
valve of meter 2.
The input signal feedback “vapour recovery valve closed” is not coherent with the command of
2.26 Vapour recovery valve not closed 3.4.4.2.1 3.4.4.2.2
valve of meter 2.
2.27 Block valve not opened The input signal feedback “block valve opened” is not coherent with the command of valve. 3.2.3.1.1 3.2.3.1.2
2.28 Block valve not closed The input signal feedback “block valve closed” is not coherent with the command of valve. 3.2.3.2.1 3.2.3.2.2
2.30 Thermal conversion enabled but temperature, density or pressure not present. Thermal conversion enabled but temperature or density or pressure not acquired. Always enabled EMERGENCY5
2.34 Preset valve not closed. Product flow after a command of closure to preset valve. 3.2.3.4.1 3.2.3.4.2
2.35 Product 1 selecting valve not rightly positioned. Selecting valve not completely closed/opened. 3.4.1.1 3.4.1.1
2.36 Product 2 selecting valve not rightly positioned. Selecting valve not completely closed/opened. 3.4.2.1 3.4.2.1
2.37 Product 3 selecting valve not rightly positioned. Selecting valve not completely closed/opened. 3.4.3.1 3.4.3.1
2.48 Pressure out of range The pressure is out of the established range 3.2.7.1 3.2.7.2
2.49 Density/Alpha or Strength acquired with 4÷20mA is out of range The density or the Alcoholic strength acquired by 4÷20mA signal is out of range. 3.2.6.1 3.2.6.2
2.72 Error in CTPL calculation It’s no possible calculate the CTPL value 3.2.5.11.1 3.2.5.11.2
2.81 Encoder error. Error of magnet of encoder Can-Bus.
Always active if par.
2.82 Encoder error. Wrong pulses sequence on encoder Can-Bus.
n°0.2.2.1 is set to 3.2.1.1.2
2.83 Encoder error. Software reset of encoder Can-Bus.
“ENCODER CAN-BUS”
2.84 Encoder error. Hardware reset of encoder Can-Bus.
2.87 Wrong counting of product. There was a problem in the counting of product. Always enabled EMERGENCY5
VEGA does not receive a valid message from the serial line programmed to use the Legally
2.91 Timeout legally relevant Modbus protocol
Modbus protocol.
3.2.8.1 3.2.8.2

Page n°78 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
5 PASSWORDS

5 Passwords
CODE/DESCRIPTION VALUES Protection
Password level 1 Minimum Maximum Default
It allows to change the password of level 1 used to enter in programming mode. 00000 99999 1221
Password level 2 Minimum Maximum Default
It allows to change the password of level 2 used to enter in programming mode. 00000 99999 2112
Reading password Minimum Maximum Default
It allows to change the reading password to enter in programming mode. 00000 99999 97531
Programming mode entry Password (Default)
It allows to choose if, for entering in programming mode, is enough the password or is also necessary to unscrew the Access to the programming menu parameters is allowed after the
(0)
Weight &Measure switch. introduction of one of the passwords (See parameters 5.1, 5.2
and 5.3).
Password + Weight & Measure switch
Access to the programming menu parameters is allowed after the
(1)
introduction of one of the passwords (See parameters 5.1, 5.2
and 5.3) and the removal of the Weight and measure switch.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°79 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
6 SERIAL LINES

6.1 Serial line 1 (RS232/485)


CODE/DESCRIPTION VALUES Protection
6.1.1 Baud rate 19200 baud (Default) (0)
Set communication speed in baud rate (bits/second).
9600 baud (1)

Clamps of VEGAII: B1-1 (+ RS485 / Tx RS232) B1-2 (- RS485 / Rx RS232) B1-3 (COM) 4800 baud (2)
See also the selector S3 to choose from RS232 and RS485.
2400 baud (3)

1200 baud (4)

6.1.2 Parity No parity (0)


Set type of parity used for message. Even parity (Default) (1)
Odd parity (2)
6.1.4 Legally relevant Protocol Not used (0)
It allows to choose which protocol is used on the line. Legally printer ST500-M (1)
MRD (Memory Recording Device) (2)
Legally rel. Modbus (Default) (3)
6.1.5 Not legally relevant Protocol Not used (Default) (0)
It allows to choose which protocol is used on the line. Proprietary protocol (1)
Printer ST500 A/B (2)
SPD (Shared Printing Device) (3)
Modbus protocol (4)
FlexiMix (5)
LFD-6 (6)
Badge reader RFID (7)

Page n°80 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
6.2 Serial line 2 (RS232/485)
CODE/DESCRIPTION VALUES Protection
6.2.1 Baud rate 19200 baud (Default) (0)
Set communication speed in baud rate (bits/second).
9600 baud (1)

Clamps of VEGAII: B1-4 (+ RS485 / Tx RS232) B1-5 (- RS485 / Rx RS232) B1-3 (COM) 4800 baud (2)
See also the selector S4 to choose from RS232 and RS485.
2400 baud (3)

1200 baud (4)

6.2.2 Parity No parity (Default) (0)


It defines the type of parity control on the characters. Even parity (1)
Odd parity (2)
6.2.3 Bits for character 7 bit (0)
Set how many bits compose a character of message.
8 bit (Default) (1)

6.2.4 Legally relevant Protocol Not used (Default) (0)


It allows to choose which protocol is used on the line. Legally printer ST500-M (1)
MRD (Memory Recording Device) (2)
Legally rel. Modbus (3)
6.2.5 Not legally relevant Protocol Not used (Default) (0)
It allows to choose which protocol is used on the line. Proprietary protocol (1)
Printer ST500 A/B (2)
SPD (Shared Printing Device) (3)
Modbus protocol (4)
FlexiMix (5)
LFD-6 (6)
Badge reader RFID (7)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°81 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
6.3 Serial line 3 (RS422/485)
CODE/DESCRIPTION VALUES Protection
6.3.1 Baud rate 19200 baud (Default) (0)
Set communication speed in baud rate (bits/second).
9600 baud (1)

Clamps of VEGAII:: B1-7 (+ Rx) B1-8 (- Rx) B1-9 (+Tx) B1-10 (-Tx) 4800 baud (2)

2400 baud (3)

1200 baud (4)

6.3.2 Parity No parity (Default) (0)


t defines the type of parity control on the characters. Even parity (1)
Odd parity (2)
6.3.3 Bits for character 7 bit (0)
Set how many bits compose a character of message.
8 bit (Default) (1)

6.3.4 Legally relevant Protocol Not used (Default) (0)


It allows to choose which protocol is used on the line. Legally printer ST500-M (1)
MRD (Memory Recording Device) (2)
Legally rel. Modbus (3)
6.3.5 Not legally relevant Protocol Not used (Default) (0)
It allows to choose which protocol is used on the line. Proprietary protocol (1)
Printer ST500 A/B (2)
SPD (Shared Printing Device) (3)
Modbus protocol (4)
FlexiMix (5)
LFD-6 (6)
Badge reader RFID (7)

Page n°82 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
6.4 Serial line 4 (RS232)
CODE/DESCRIPTION VALUES Protection
6.4.1 Baud rate 19200 baud (Default) (0)
Set communication speed in baud rate (bits/second).
9600 baud (1)

4800 baud (2)

2400 baud (3)

1200 baud (4)

6.4.2 Parity No parity (Default) (0)


It defines the type of parity control on the characters. Even parity (1)
Odd parity (2)
6.4.3 Bits for character 7 bit (0)
Set how many bits compose a character of message.
8 bit (Default) (1)

6.4.4 Legally relevant Protocol Not used (Default) (0)


It allows to choose which protocol is used on the line. Legally printer ST500-M (1)
MRD (Memory Recording Device) (2)
Legally rel. Modbus (3)
6.4.5 Not legally relevant Protocol Not used (Default) (0)
It allows to choose which protocol is used on the line. Proprietary protocol (1)
Printer ST500 A/B (2)
SPD (Shared Printing Device) (3)
Modbus protocol (4)
FlexiMix (5)
LFD-6 (6)
Badge reader RFID (7)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°83 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7 AUTOMATION

7.1 General features 7.1.1 Operating mode


CODE/DESCRIPTION VALUES Description of values Protection
7.1.1 Operating mode Local (Default) VEGA works only in Local mode (0)
It defines if the delivery of product is controlled in Local or Remote mode: Remote VEGA works only in Remote mode (1)
- in Local mode VEGA manages directly the delivery operations, Local & Remote VEGA works in Local or Remote mode based on the
- in Remote mode the delivery is controlled by the automation protocol (Proprietary or ModBus). position of the external selector connected to VEGA (2)
It’s possible to choose the function mode (Local or Remote) with an external selector connected to one digital by one of its input.
input of VEGA.

7.1 General features 7.1.2 Local mode 7.1.2.1 Transaction closing


CODE/DESCRIPTION VALUES Protection
7.1.2.1.1 Enable transaction closing” Enabled (0)
It enables/disables the management of the transaction closing in Local mode. Disabled (Default) (1)
7.1.2.1.2 Type of transaction closing CLEAR button (Default) (0)
It defines if the closure of the transaction will be made by push-button CLEAR or automatically when a series of digital
inputs, until six, assume programmed status. If using the RFID Badge Reader, transaction will be closed when the badge INPUTS (1)

is removed. BADGE (2)

7.1.2.1.3 Number of first input


Minimum Maximum Default
These parameters are active only if previous parameter is set with the value “Input” and VEGA is in Local mode.
See DIGITAL INPUT TABLE to identify the corresponding clamp.
NOTE: Set the value “0” for not using. 0 32 0

7.1.2.1.4 Logic position first input Opened (Default) (0)


Logic state that the input has to assume in order to close the transaction.
The transaction closing will be activated when all the programmed inputs assume the programmed logic state. Closed (1)

7.1.2.1.5 Number of second input Minimum Maximum Default


As for par. 7.1.2.1.3 0 32 0
7.1.2.1.6 Logic position second input Opened (Default) (0)
As for par. 7.1.2.1.4 Closed (1)
7.1.2.1.7 Number of third input Minimum Maximum Default
As for par. 7.1.2.1.3 0 32 0
7.1.2.1.8 Logic position third input Opened (Default) (0)
As for par. 7.1.2.1.4 Closed (1)
7.1.2.1.9 Number of fourth input Minimum Maximum Default
As for par. 7.1.2.1.3 0 32 0
7.1.2.1.10 Logic position fourth input Opened (Default) (0)
As for par. 7.1.2.1.4 Closed (1)
7.1.2.1.11 Number of fifth input Minimum Maximum Default
As for par. 7.1.2.1.3 0 32 0
7.1.2.1.12 Logic position fifth input Opened (Default) (0)
As for par. 7.1.2.1.4 Closed (1)

Page n°84 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.1 General features 7.1.2 Local mode
CODE/DESCRIPTION VALUES Protection
7.1.2.2 Reset quantity Local mode Automatic (0)
It allows to choose how to reset the delivery data of a batch or transaction when VEGA works in Local mode. By request (Default) (1)

7.1 General features 7.1.3 Remote mode


CODE/DESCRIPTION VALUES Protection
7.1.3.1 Alarm reset By protocol (Default) (0)
It allows to choose how to reset an alarm when VEGA works in remote mode. By protocol or CLEAR (Default) (1)
7.1.3.2 Batch closing
Disabled (Default) (0)
It allows to enable functionality that if operator push STOP during a delivery and loading is stopped, if he push again STOP
because he wants to close batch, VEGAII asks to the automation system to close the batch.
Enabled (1)

7.1.3.3 Data storing


It enables/disables the management of store data, if the parameter is set to enable at the end of batch/transaction VEGAII Disabled (0)
set the flag “Status batch”/”Status transaction” at the value “Data ready to be stored” and the head wait the serial command
of Batch/Transaction data stored.
If the parameter is disable at the end of batch/transaction the flag “Status batch”/”Status transaction” will be not set to “Data
Enabled (Default) (1)
ready to be stored” and the head goes in next operative phase without waiting a serial command of Batch/Transaction data
stored.
7.1.3.4.1 Transaction management enabling
It enables/disables management of loading by transaction (more batches), if it’s enabled to deliver product you will have to Disabled (0)
send “Start transaction” and “Close transaction” serial messages.
Enabled (Default) (1)

7.1.3.4.2 Operating mode


Semiautomatic (0)
It defines if in remote working mode with transaction management disabled VEGAII operate in Semiautomatic or Automatic
mode.
In Semiautomatic mode operator could choose product to deliver and set preset quantity. Automatic (Default) (1)
In Automatic mode all will be done by TAS.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°85 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.1 General features 7.1.4 Preset
CODE/DESCRIPTION VALUES Description of values Protection
7.1.4.1 Preset management VEGA does not use preset function and preset valve.
Preset NO / Start-Stop NO (0)
It allows to choose if the preset function (predetermined quantity that This option is normally used in a pipeline.
must be delivered) has to be used. VEGA does not use preset function but opens and closes the preset valve with the
command of start and stop.
Preset NO / Start-Stop Yes (1)
This option is normally used for a delivery where the quantity is unknown but is
necessary to start and stop the flow with a valve.
Preset Yes /Start Yes
VEGA uses the preset function and the preset valve. (2)
(Default)

7.1 General features 7.1.4 Preset


CODE/DESCRIPTION VALUES Protection
7.1.4.2 Repeat preset value Enabled (0)
It enables/disables the use of the same preset value for the next batch. Disabled (Default) (1)

7.1 General features 7.1.4 Preset 7.1.4.3 Preset limits


CODE/DESCRIPTION VALUES Protection
7.1.4.3.1 Minimum presettable quantity Minimum Maximum Default
Minimum presettable quantity. 0 Par. 7.1.4.3.2 100,000
7.1.4.3.2 Maximum presettable quantity
Maximum presettable quantity. Par. 7.1.4.3.1 9999999 9999999,999

7.1 General features 7.1.5 Pin code/Badge


CODE/DESCRIPTION VALUES Protection
7.1.5.1 Management Disabled (Default) (0)
It defines if “Pin Code/Badge” has to be required before a new batch or a transaction.
If enabled, the operator has to input a numeric code (Pin Code) before to initiate the delivery or insert the badge in RFID reader Always Enabled (1)

if enabled by serial line. Enabled in remote (2)

7.1.5.2 Timeout Minimum Maximum Default


Pin code/Badge is automatically erased if delivery doesn’t start before the end of this time.
0 999 0
Entering ‘0’ will disable the timeout.
7.1.5.3 Characters of Pin Code
1 12 6
Maximum number of characters used for the Pin Code.
7.1.5.4 Type of Pin Code Numeric (Default)
The Pin Code is composed only of
(0)
numeric value
It allows to choose if the Pin Code is represented like a numeric or alphanumeric value. The Pin Code can be composed with
Alphanumeric numeric value or alphabetic characters
(1)

7.1 General features 7.1.6 Product selection mode


CODE/DESCRIPTION VALUES Protection
7.1.6 Product selection Keyboard (Default) (0)
In local or semiautomatic mode selection of product to deliver when more than a products are enabled may be done by VEGAII
keyboard or by an external selector connected to VEGAII input. Selector (1)

Page n°86 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.1 General features 7.1.7 Transactions & batches number
CODE/DESCRIPTION VALUES Protection
7.1.7.1 Transactions Minimum Maximum Default
Number of transactions delivered. Value is automatically updated by VEGA at the end of transaction.
0 999999 0
7.1.7.2 Batches Minimum Maximum Default
Number of batches delivered. Value is automatically updated by VEGA at the end of batch.
0 999999 0
7.1.7.3 Legally relevant measurements Minimum Maximum Default
Number of “Legally relevant measurements” delivered. Value is automatically updated by VEGA at the end of a delivery.
0 999999 0

7.2 Inputs 7.2.1 Digital inputs


DESCRIPTION CODE VALUES Protection
Input number Minimum Maximum Default
It defines the number of input to be programmed. -------
1 32 1
Type
Not used (Default) (0)
It defines the type of function linked with the input.
The input can be programmed as: See Power
Interlock (1)
 Interlock: during the delivery when the contact is in “not OK position” (se par. supply board
Contact) VEGA activates the action programmed into the parameter Action; out of Input table
delivery the “not OK position” does not give the permission to start the delivery. Signal (2)
 Signal: the input can be linked with a specific function.
Contact (only for inputs programmed as Interlock)
See Power OK if OPEN (0)
It defines the logic state of the contact connected with the input to give a permission to deliver
supply board
the product.
Input table OK if CLOSED (Default) (1)

Action (only for inputs programmed as Interlock) Standard (Default) (0)


It allows to select the action that will be activated when the Interlock is not OK. See Power Action 1 (1)
supply board
Input table Action 2 (2)

Action 3 (3)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°87 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.2 Inputs 7.2.1 Digital inputs
CODE VALUES
DESCRIPTION Protection
Interlocks Signals
Name Interlock number (0) Generic signal (50)
Grounding unit (1) Remote start (51)
When the input is programmed as an Interlock it allows to associate it with a defined
Loading arm (2) Remote stop (52)
name or a custom name that is visualized on display when the interlock in not OK. Manual valve (3) Local / Remote selector (53)
When the input is programmed as a Signal it allows to link it with a defined function. Vapour recovery valve (4) Overfilling by-pass (54)
Overfilling (5) Vapour recovery valve of meter 1 opened (55)
Tank truck presence (6) Vapour recovery valve of meter 1 closed (56)
Interlock by badge reader (7) Vapour recovery valve of meter 2 opened (57)
Dead man (8) Vapour recovery valve of meter 2 closed (58)
Dirty filter (9) Block valve of meter 1 opened (59)
Emergency (10) Block valve of meter 1 closed (60)
Bay locked (11) Block valve of meter 2 opened (61)
Remote emergency (12) Block valve of meter 2 closed (62)
Vapour recovery (13) Selecting valve of product 1 of meter 1 opened (63)
Tank level (14) Selecting valve of product 2 of meter 1 opened (64)
Interlock custom name 1 (parameter 7.2.4.1 value) (15) Selecting valve of product 3 of meter 1 opened (65)
Interlock custom name 2 (parameter 7.2.4.2 value) (16) Selecting valve of product 1 of meter 2 opened (66)
See next
Interlock custom name 3 (parameter 7.2.4.3 value) (17) Selecting valve of product 2 of meter 2 opened (67)
tables Selecting valve of product 3 of meter 2 opened (68)
Selecting valve of product 1 of meter 1 closed (69)
Selecting valve of product 2 of meter 1 closed (70)
Selecting valve of product 3 of meter 1 closed (71)
Selecting valve of product 1 of meter 2 closed (72)
Selecting valve of product 2 of meter 2 closed (73)
Selecting valve of product 3 of meter 2 closed (74)
Product 1 selection (75)
Product 2 selection (76)
Product 3 selection (77)
Additive system 1not ready (78)
Additive system 2 not ready (79)
Start/Stop ON/OFF (80)
Gas extractor level (LF) Meter 1 (81)
Gas extractor level (STOP) Meter 1 (82)
Gas extractor level (LF) Meter 2 (83)
Gas extractor level (STOP) Meter 2 (84)

Page n°88 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
Power supply board - Input table
PARAMETER
Input number Clamp
Type Contact Action Name
1 E1-2 7.2.1.1.1 7.2.1.1.2 7.2.1.1.5 7.2.1.1.6
2 E1-3 7.2.1.2.1 7.2.1.2.2 7.2.1.2.5 7.2.1.2.6
3 E1-4 7.2.1.3.1 7.2.1.3.2 7.2.1.3.5 7.2.1.3.6
4 E1-5 7.2.1.4.1 7.2.1.4.2 7.2.1.4.5 7.2.1.4.6
5 E1-6 7.2.1.5.1 7.2.1.5.2 7.2.1.5.5 7.2.1.5.6
6 E1-7 7.2.1.6.1 7.2.1.6.2 7.2.1.6.5 7.2.1.6.6
7 E1-8 7.2.1.7.1 7.2.1.7.2 7.2.1.7.5 7.2.1.7.6
8 E1-9 7.2.1.8.1 7.2.1.8.2 7.2.1.8.5 7.2.1.8.6
9 E2-2 7.2.1.9.1 7.2.1.9.2 7.2.1.9.5 7.2.1.9.6
10 E2-3 7.2.1.10.1 7.2.1.10.2 7.2.1.10.5 7.2.1.10.6
11 E2-4 7.2.1.11.1 7.2.1.11.2 7.2.1.11.5 7.2.1.11.6
12 E2-5 7.2.1.12.1 7.2.1.12.2 7.2.1.12.5 7.2.1.12.6
13 E2-6 7.2.1.13.1 7.2.1.13.2 7.2.1.13.5 7.2.1.13.6
14 E2-7 7.2.1.14.1 7.2.1.14.2 7.2.1.14.5 7.2.1.14.6
15 E2-8 7.2.1.15.1 7.2.1.15.2 7.2.1.15.5 7.2.1.15.6
16 E2-9 7.2.1.16.1 7.2.1.16.2 7.2.1.16.5 7.2.1.16.6

Digital I/O board - Input table


PARAMETER
Input number Clamp
Type Contact Action Name
17 D1-2 7.2.2.1.1 7.2.2.1.2 7.2.2.1.5 7.2.2.1.6
18 D1-3 7.2.2.2.1 7.2.2.2.2 7.2.2.2.5 7.2.2.2.6
19 D1-4 7.2.2.3.1 7.2.2.3.2 7.2.2.3.5 7.2.2.3.6
20 D1-5 7.2.2.4.1 7.2.2.4.2 7.2.2.4.5 7.2.2.4.6
21 D1-6 7.2.2.5.1 7.2.2.5.2 7.2.2.5.5 7.2.2.5.6
22 D1-7 7.2.2.6.1 7.2.2.6.2 7.2.2.6.5 7.2.2.6.6
23 D1-8 7.2.2.7.1 7.2.2.7.2 7.2.2.7.5 7.2.2.7.6
24 D1-9 7.2.2.8.1 7.2.2.8.2 7.2.2.8.5 7.2.2.8.6
25 D2-2 7.2.2.9.1 7.2.2.9.2 7.2.2.9.5 7.2.2.9.6
26 D2-3 7.2.2.10.1 7.2.2.10.2 7.2.2.10.5 7.2.2.10.6
27 D2-4 7.2.2.11.1 7.2.2.11.2 7.2.2.11.5 7.2.2.11.6
28 D2-5 7.2.2.12.1 7.2.2.12.2 7.2.2.12.5 7.2.2.12.6
29 D2-6 7.2.2.13.1 7.2.2.13.2 7.2.2.13.5 7.2.2.13.6
30 D2-7 7.2.2.14.1 7.2.2.14.2 7.2.2.14.5 7.2.2.14.6
31 D2-8 7.2.2.15.1 7.2.2.15.2 7.2.2.15.5 7.2.2.15.6
32 D2-9 7.2.2.16.1 7.2.2.16.2 7.2.2.16.5 7.2.2.16.6

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°89 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.2 Inputs 7.2.2 Analog inputs 7.2.2.1 Pt100 correction of Meter 1
CODE/DESCRIPTION VALUES Protection
7.2.2.1.2 Pt100 correction of Meter 1 Minimum Maximum Default
Value to be added to compensate the difference between the value on VEGA with the value measured with a sample
instrument. Value is calculated as displayed below: -5.0 5.0 0.0
VALUE TO INSERT = TEMPERATURE OF THERMOMETER – (VEGA TEMPERATURE + PARAMETER VALUE)

7.2 Inputs 7.2.2 Analog inputs 7.2.2.2 Pt100 correction of Meter 2


CODE/DESCRIPTION VALUES Protection
7.2.2.2.2 Pt100 correction of Meter 2 Minimum Maximum Default
Value to be added to compensate the difference between the value on VEGA with the value measured with a sample
instrument. Value is calculated as displayed below: -5.0 5.0 0.0
VALUE TO INSERT = TEMPERATURE OF THERMOMETER – (VEGA TEMPERATURE + PARAMETER VALUE)

7.2 Inputs 7.2.3 Analog inputs 7.2.2.3 Input 1 4-20mA


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
7.2.2.3.1 Offset in mA
Value to be added to compensate the difference between the value measured by VEGA with the value measured by a
-2.0 2.0 0.0
sample instrument. The value is calculated as follows:
VALUE TO INPUT = Instrument value – (VEGA value + Value already present on parameter)
7.2.2.3.2 Enable/Disable acquisition of input Disabled (Default) (0)
It allows to enable/disable the acquisition of the analog input value. Enabled (1)

7.2 Inputs 7.2.3 Analog inputs 7.2.2.4 Input 2 4-20mA


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
7.2.2.4.1 Offset in mA
Value to be added to compensate the difference between the value measured by VEGA with the value measured by a
-2.0 2.0 0.0
sample instrument. The value is calculated as follows:
VALUE TO INPUT = Instrument value – (VEGA value + Value already present on parameter)
7.2.2.4.2 Enable/Disable acquisition of input Disabled (Default) (0)
It allows to enable/disable the acquisition of analog input value. Enabled (1)

Page n°90 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.2 Inputs 7.2.3 Interlocks actions 7.2.3.1 Action 1
CODE/DESCRIPTION VALUES Protection
7.2.3.1.1 Preset valve closing Disabled (0)
It enables/disables the closure of the preset valve when the emergency is activated. Enabled (Default) (1)
7.2.3.1.2 Alarm output disabling Disabled (0)
It enables/disables the alarm output when the emergency is activated. Enabled (Default) (1)
7.2.3.1.3 Selecting valve closing Disabled (0)
It enables/disables the closure of the selecting valve when the emergency is activated. Enabled (Default) (1)
7.2.3.1.4 Product pump switching off Disabled (0)
It enables/disables the switching off of the product pump when the emergency is activated. Enabled (Default) (1)
7.2.3.1.5 Block valve closing Disabled (0)
It enables/disables the closure of the block valve when the emergency is activated. Enabled (Default) (1)
7.2.3.1.6 Output activated (number) Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated.
0 32 0
By setting the value ‘0’ no output will be activated.

7.2 Inputs 7.2.3 Interlocks actions 7.2.3.2 Action 2


CODE/DESCRIPTION VALUES Protection
7.2.3.2.1 Preset valve closing Disabled (0)
It enables/disables the closure of the preset valve when the emergency is activated. Enabled (Default) (1)
7.2.3.2.2 Alarm output disabling Disabled (0)
It enables/disables the alarm output when the emergency is activated. Enabled (Default) (1)
7.2.3.2.3 Selecting valve closing Disabled (Default) (0)
It enables/disables the closure of the selecting valve when the emergency is activated. Enabled (1)
7.2.3.2.4 Product pump switching off Disabled (Default) (0)
It enables/disables the switching off of the product pump when the emergency is activated. Enabled (1)
7.2.3.2.5 Block valve closing Disabled (Default) (0)
It enables/disables the closure of the block valve when the emergency is activated. Enabled (1)
7.2.3.2.6 Output activated (number) Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated. 0 32 0

7.2 Inputs 7.2.3 Interlocks actions 7.2.3.3 Action 3


CODE/DESCRIPTION VALUES Protection
7.2.3.3.1 Preset valve closing Disabled (0)
It enables/disables the closure of the preset valve when the emergency is activated. Enabled (Default) (1)
7.2.3.3.2 Alarm output disabling Disabled (0)
It enables/disables the alarm output when the emergency is activated. Enabled (Default) (1)
7.2.3.3.3 Selecting valve closing Disabled (Default) (0)
It enables/disables the closure of the selecting valve when the emergency is activated. Enabled (1)
7.2.3.3.4 Product pump switching off Disabled (Default) (0)
It enables/disables the switching off of the product pump when the emergency is activated. Enabled (1)
7.2.3.3.5 Block valve closing Disabled (Default) (0)
It enables/disables the closure of the block valve when the emergency is activated. Enabled (1)
7.2.3.3.6 Output activated (number) Minimum Maximum Default
It allows to activate one of the digital outputs of VEGA when the emergency is activated. 0 32 0

7.2 Inputs

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°91 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.2.4 Interlocks custom names
7.2.4.1 Custom name 1
7.2.4.2 Custom name 2
7.2.4.3 Custom name 3
VALUES
CODE/DESCRIPTION CODE LINE Protection
Minimum Maximum Default
Custom name 1 7.2.4.1.1 Line 1 0 Characters 14 Characters Custom name 1
These parameters allows to enter a name of maximum 14 characters for 4 lines, that will be 7.2.4.1.2 Line 2 0 Characters 14 Characters
visualized when the relative interlock is not OK. 7.2.4.1.3 Line 3 0 Characters 14 Characters
7.2.4.1.4 Line 4 0 Characters 14 Characters
Custom name 2 7.2.4.2.1 Line 1 0 Characters 14 Characters Custom name 2
These parameters allows to enter a name of maximum 14 characters for 4 lines, that will be 7.2.4.2.2 Line 2 0 Characters 14 Characters
visualized when the relative interlock is not OK. 7.2.4.2.3 Line 3 0 Characters 14 Characters
7.2.4.2.4 Line 4 0 Characters 14 Characters
Custom name 3 7.2.4.3.1 Line 1 0 Characters 14 Characters Custom name 3
These parameters allows to enter a name of maximum 14 characters for 4 lines, that will be 7.2.4.3.2 Line 2 0 Characters 14 Characters
visualized when the relative interlock is not OK. 7.2.4.3.3 Line 3 0 Characters 14 Characters
7.2.4.3.4 Line 4 0 Characters 14 Characters

Page n°92 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.3 Outputs 7.3.1 Digital outputs
DESCRIPTION CODE VALUES Protection
Output number – It allows to set the number of the output Minimum Maximum Default
to be linked with the relative Type of function -------
1 32 1
Type of function. Function type Function description
Not used (0) The output is not used by VEGA
Solenoid valve LF = Low Flow NC = Normally Closed OC = Open Close
LF /NC/OC of preset valve of meter 1 (1)
Two stage Multistep OPEN/CLOSE
Solenoid valve HF = High Flow NO = Normally Open
HF/NO of preset valve of meter 1 (2)
Two stage Multistep
Solenoid valve LF = Low Flow NC = Normally Closed OC = Open Close
LF /NC/OC of preset valve of meter 2 (3)
Two stage Multistep OPEN/CLOSE
Solenoid valve HF = High Flow NO = Normally Open
HF/NO of preset valve of meter 2 (4)
Two stage Multistep
It is activated at the START of the batch when the product 1 of meter 1is selected and deactivated at the end of
Pump of product 1 of meter 1 (5) batch after the delay programmed par. 7.4.1.7 or immediately when an alarm or an interlock absence happens
and in Emergency functions or Interlock action is set to deactivate pump output.
Pump of product 2 of meter 1 (6) As for pump of product 1 of meter 1.
Pump of product 3 of meter 1 (7) As for pump of product 1 of meter 1.
It is activated at the START of the batch when the product 1 of meter 2 is selected and deactivated at the end of
Pump of product 1 of meter 2 (8) batch after the delay programmed par. 7.4.2.7 or immediately when an alarm or an interlock absence happens
and in Emergency functions or Interlock action is set to deactivate pump output.
Pump of product 2 of meter 2 (9) As for pump of product 2 of meter 2.
Pump of product 3 of meter 2 (10) As for pump of product 3 of meter 2.
It is activated at the START of the batch when the product 1 of meter 1 is selected and deactivated at the end of
Selecting valve of product 1 of meter 1 (11) batch after the delay programmed par. 7.4.1.9 or immediately when an alarm or an interlock absence happens
and in Emergency functions or Interlock action is set to deactivate pump output.
Selecting valve of product 2 of meter 1 (12) As for selecting valve of product 1 of meter 1
Selecting valve of product 3 of meter 1 (13) As for selecting valve of product 1 of meter 1
It is activated at the START of the batch when the product 1 of meter 2 is selected and deactivated at the end of
Selecting valve of product 1 of meter 2 (14) batch after the delay programmed par. 7.4.2.9 or immediately when an alarm or an interlock absence happens
See next and in Emergency functions or Interlock action is set to deactivate pump output.
Selecting valve of product 2 of meter 2 (15) As for selecting valve of product 1 of meter 2.
table
Selecting valve of product 3 of meter 2 (16) As for selecting valve of product 1 of meter 2.
Alarm condition (17) Normally active, it is deactivated by an Emergency, an Action or when the main power supply fails.
It is activated at the START of delivery and deactivated at the end of batch or transaction (see parameter 7.4.1.8)
Block valve of meter 1 (18) or when an alarm or an interlock absence happens and in Emergency functions or Interlock action is set to
deactivate block valve output.
It is activated at the START of delivery and deactivated at the end of batch or transaction (see parameter 7.4.2.8)
Block valve of meter 2 (19) or when an alarm or an interlock absence happens and in Emergency functions or Interlock action is set to
deactivate block valve output.
Vapour recovery valve of meter 1 (20) As for product pumps.
Vapour recovery valve of meter 2 (21) As for product pumps.
Pulses reset (22) It is activated for 0,5 seconds when the delivery data are zeroed.
Enable of additivation system 1 (23) Output used to manage external smart injection additive system. See par. 8.2.
Enable of additivation system 2 (24) Output used to manage external smart injection additive system. See par. 8.2.
Additive cleaning line (25) Output managed on base of the parameter 8.1.4.
Additive selection 1 (26) Output used to manage external smart injection additive system. See par. 8.2.
Additive selection 2 (27) Output used to manage external smart injection additive system. See par. 8.2.
Additive selection 3 (28) Output used to manage external smart injection additive system. See par. 8.2.
Additive selection 4 (29) Output used to manage external smart injection additive system. See par. 8.2.
1 (30) It is activated when product 1 is selected.
Product 2 (31) It is activated when product 2 is selected.
Product 3 (32) It is activated when product 3 is selected.
Product 1 of meter 1 (33) It is activated when the Product 1 of meter 1 is selected.
Product 2 of meter 1 (34) It is activated when the Product 2 of meter 1 is selected.
Product 3 of meter 1 (35) It is activated when the Product 3 of meter 1 is selected.
Product 1 of meter 2 (36) It is activated when the Product 1 of meter 2 is selected.
Product 2 of meter 2 (37) It is activated when the Product 2 of meter 2 is selected.
Product 3 of meter 2 (38) It is activated when the Product 3 of meter 2 is selected.

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°93 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
POWER SUPPLY BOARD OUTPUT TABLE
PARAMETERS
Output n° CLAMP
CODE DEFAULT
1 E5-2 7.3.1.1 Not used
2 E5-3 7.3.1.2 Not used
3 E5-4 7.3.1.3 Not used
4 E5-5 7.3.1.4 Not used
5 E5-6 7.3.1.5 Not used
6 E5-7 7.3.1.6 Not used
7 E5-8 7.3.1.7 Not used
8 E5-9 7.3.1.8 Not used
9 E6-1/E6-3 7.3.1.9 LF /NC/OC of preset valve of meter 1
10 E6-2/E6-3 7.3.1.10 HF/NO of preset valve of meter 1
11 E6-4/E6-6 7.3.1.11 Pump of product 1 of meter 1
12 E6-5/E6-6 7.3.1.12 Not used
13 E6-7/E6-9 7.3.1.13 Not used
14 E6-8/E6-9 7.3.1.14 Not used
15 E6-10/E6-12 7.3.1.15 Not used
16 E6-11/E6-12 7.3.1.16 Alarm condition

DIGITAL I/O BOARD OUTPUT TABLE


PARAMETERS
Output n° CLAMP
CODE DEFAULT
17 E5-2 7.3.2.1 Not used
18 E5-3 7.3.2.2 Not used
19 E5-4 7.3.2.3 Not used
20 E5-5 7.3.2.4 Not used
21 E5-6 7.3.2.5 Not used
22 E5-7 7.3.2.6 Not used
23 E5-8 7.3.2.7 Not used
24 E5-9 7.3.2.8 Not used
25 E6-1/E6-3 7.3.2.9 Not used
26 E6-2/E6-3 7.3.2.10 Not used
27 E6-4/E6-6 7.3.2.11 Not used
28 E6-5/E6-6 7.3.2.12 Not used
29 E6-7/E6-9 7.3.2.13 Not used
30 E6-8/E6-9 7.3.2.14 Not used
31 E6-10/E6-12 7.3.2.15 Not used
32 E6-11/E6-12 7.3.2.16 Not used

Page n°94 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.3 Outputs 7.3.2 Analog outputs 7.3.2.1 Output 1 4-20mA
CODE/DESCRIPTION VALUES Protection
7.3.2.1.1 Data represented No one (Default) (0)
Data represented on OUTPUT1 4-20mA. Differential flow rate (1)
VEGAII clamps: C3-3 (+) and C3-4 (-). Differential aver. Flow rate (2)
Meter 1 flow rate (3)
Meter 1 aver. flow rate (4)
Meter 2 flow rate (5)
Meter 2 aver. flow rate (6)
Met.1 temperature (7)
Met.1 aver. temperature (8)
Met.2 temperature (9)
Met.2 aver. temperature (10)
Met.1 valve 4-20mA (11)
Met.2 valve 4-20mA (12)
7.3.2.1.2 Value of data at 4mA Minimum Maximum Default
Value of the unit of measure represented with 4mA. Flow rate Temperature Flow rate Temperature Flow rate Temp.
-40°C -40°C
0,0 Par. 7.3.2.1.3 0,0
-40°F -40°F
7.3.2.1.3 Value of data at 20mA Minimum Maximum Default
Value of the unit of measure represented with 20mA. Flow rate Temperature Flow rate Temperature Flow rate Temp.
240°C 240°C
Par. 7.3.2.1.2 99999,9 99999,9
473°F 473°F
7.3.2.1.4 Correction of 4-20mA Minimum Maximum Default
Value to be added to compensate the difference between the value measured by VEGA with the value
measured by a sample instrument.
-2,00 2,00 0,00
The value is calculated as follows: VALUE TO INPUT = Instrument value – (VEGA value + Value already
present on parameter)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°95 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.3 Outputs 7.3.2 Analog outputs 7.3.2.2 Output 2 4-20mA
CODE/DESCRIPTION VALUES Protection
7.3.2.2.1 Data represented No one (Default) (0)
Data represented on OUTPUT2 4-20mA. Differential flow rate (1)
VEGAII clamps: C3-1 (+) and C3-2 (-). Differential aver. Flow rate (2)
Meter 1 flow rate (3)
Meter 1 aver. flow rate (4)
Meter 2 flow rate (5)
Meter 2 aver. flow rate (6)
Met.1 temperature (7)
Met.1 aver. temperature (8)
Met.2 temperature (9)
Met.2 aver. temperature (10)
Met.1 valve 4-20mA (11)
Met.2 valve 4-20mA (12)
7.3.2.2.2 Value of data at 4mA Minimum Maximum Default
Value of the unit of measure represented with 4mA. Flow rate Temperature Flow rate Temperature Flow rate Temp.
-40°C -40°C
0,0 Par. 7.3.2.2.3 0,0
-40°F -40°F
7.3.2.2.3 Value of data at 20mA Minimum Maximum Default
Value of the unit of measure represented with 20mA. Flow rate Temperature Flow rate Temperature Flow rate Temp.
240°C 240°C
Par. 7.3.2.2.2 99999,9 99999,9
473°F 473°F
7.3.2.2.4 Correction of 4-20mA Minimum Maximum Default
Value to be added to compensate the difference between the value measured by VEGA with the value
measured by a sample instrument.
-2,00 2,00 0,00
The value is calculated as follows: VALUE TO INPUT = Instrument value – (VEGA value + Value already
present on parameter)

Page n°96 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.3 Outputs 7.3.3 Pulses outputs 7.3.3.1 Pulses output 1
CODE/DESCRIPTION VALUES Value description Protection
7.3.3.1.1 Data represented No one (Default) (0) This output is not used
Differential gross volume (1) The output emits pulses that represent the gross volume of differential.
It allows to choose which type of data is represented by the pulses emitted by this Differential gross standard volume (2) The output emits pulses that represent the gross standard volume of differential.
output. Differential mass (3) The output emits pulses that represent the mass of differential.
Meter 1 gross volume (4) The output emits pulses that represent the gross volume of Meter 1.
Clamps of VEGAII: B3-2. Meter 1 gross standard volume (5) The output emits pulses that represent the gross standard volume of Meter 1.
Meter 1 mass (6) The output emits pulses that represent the mass of Meter 1.
Example: To emit one pulse every 20 litres, set “Volume” and the value “20” into the Meter 2 gross volume (7) The output emits pulses that represent the gross volume of Meter 2.
parameter “Ratio units of measurement/pulses”. Meter 2 gross standard volume (8) The output emits pulses that represent the gross standard volume of Meter 2.
Meter 2 mass (9) The output emits pulses that represent the mass of Meter 2.
Additivation system 1 (10) Only if the additivation system 1 is used. The data emitted is the same of the preset
Additivation system 2 (11) Only if the additivation system 2 is used. The data emitted is the same of the preset.
Additivation systems 1&2 (12) Only if the additivation system 1or 2 are used. The data emitted is the same of the preset.
FlexiMix (13) Only if FlexiMix is used. The data emitted is the same of the preset.
7.3.3.1.2 Ratio units of measurement/pulses Minimum Maximum Default
It allows to set the ratio between the units measured and pulses to emit. 0,0001 99999,9999 1,0

7.3 Outputs 7.3.3 Pulses outputs 7.3.3.2 Pulses output 2


CODE/DESCRIPTION VALUES Value description Protection
7.3.3.2.1 Data represented No one (Default) (0) This output is not used
Differential gross volume (1) The output emits pulses that represent the gross volume of differential.
It allows to choose which type of data is represented by the pulses emitted by this Differential gross standard volume (2) The output emits pulses that represent the gross standard volume of differential.
output... Differential mass (3) The output emits pulses that represent the mass of differential.
Clamps of VEGAII: B3-3. Meter 1 gross volume (4) The output emits pulses that represent the gross volume of Meter 1.
Example: To emit one pulse every 20 litres, set “Volume” and the value “20” into the Meter 1 gross standard volume (5) The output emits pulses that represent the gross standard volume of Meter 1.
Meter 1 mass (6) The output emits pulses that represent the mass of Meter 1.
parameter “Ratio units of measurement/pulses”. Meter 2 gross volume (7) The output emits pulses that represent the gross volume of Meter 2.
Meter 2 gross standard volume (8) The output emits pulses that represent the gross standard volume of Meter 2.
Meter 2 mass (9) The output emits pulses that represent the mass of Meter 2.
Additivation system 1 (10) Only if the additivation system 1 is used. The data emitted is the same of the preset
Additivation system 2 (11) Only if the additivation system 2 is used. The data emitted is the same of the preset.
Additivation systems 1&2 (12) Only if the additivation system 1or 2 are used. The data emitted is the same of the preset.
FlexiMix (13) Only if FlexiMix is used. The data emitted is the same of the preset.
7.3.3.2.2 Ratio units of measurement/pulses Minimum Maximum Default
It allows to set the ratio between the units measured and pulses to emit. 0,0001 99999,9999 1,0

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°97 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.3 Outputs 7.3.3 Pulses outputs 7.3.3.3 Pulses output 3
CODE/DESCRIPTION VALUES Value description Protection
7.3.3.3.1 Data represented No one (Default) (0) This output is not used
Differential gross volume (1) The output emits pulses that represent the gross volume of differential.
It allows to choose which type of data is represented by the pulses emitted by this Differential gross standard volume (2) The output emits pulses that represent the gross standard volume of differential.
output... Differential mass (3) The output emits pulses that represent the mass of differential.
Clamps of VEGAII: B3-4. Meter 1 gross volume (4) The output emits pulses that represent the gross volume of Meter 1.
Example: To emit one pulse every 20 litres, set “Volume” and the value “20” into the Meter 1 gross standard volume (5) The output emits pulses that represent the gross standard volume of Meter 1.
Meter 1 mass (6) The output emits pulses that represent the mass of Meter 1.
parameter “Ratio units of measurement/pulses”. Meter 2 gross volume (7) The output emits pulses that represent the gross volume of Meter 2.
Meter 2 gross standard volume (8) The output emits pulses that represent the gross standard volume of Meter 2.
Meter 2 mass (9) The output emits pulses that represent the mass of Meter 2.
Additivation system 1 (10) Only if the additivation system 1 is used. The data emitted is the same of the preset
Additivation system 2 (11) Only if the additivation system 2 is used. The data emitted is the same of the preset.
Additivation systems 1&2 (12) Only if the additivation system 1or 2 are used. The data emitted is the same of the preset.
FlexiMix (13) Only if FlexiMix is used. The data emitted is the same of the preset.
7.3.3.3.2 Ratio units of measurement/pulses Minimum Maximum Default
It allows to set the ratio between the units measured and pulses to emit. 0,0001 99999,9999 1,0

7.3 Outputs 7.3.3 Pulses outputs 7.3.3.4 Pulses output 4


CODE/DESCRIPTION VALUES Value description Protection
7.3.3.4.1 Data represented No one (Default) (0) This output is not used
Differential gross volume (1) The output emits pulses that represent the gross volume of differential.
It allows to choose which type of data is represented by the pulses emitted by this Differential gross standard volume (2) The output emits pulses that represent the gross standard volume of differential.
output... Differential mass (3) The output emits pulses that represent the mass of differential.
Clamps of VEGAII: B3-5. Meter 1 gross volume (4) The output emits pulses that represent the gross volume of Meter 1.
Example: To emit one pulse every 20 litres, set “Volume” and the value “20” into the Meter 1 gross standard volume (5) The output emits pulses that represent the gross standard volume of Meter 1.
Meter 1 mass (6) The output emits pulses that represent the mass of Meter 1.
parameter “Ratio units of measurement/pulses”.
Meter 2 gross volume (7) The output emits pulses that represent the gross volume of Meter 2.
Meter 2 gross standard volume (8) The output emits pulses that represent the gross standard volume of Meter 2.
Meter 2 mass (9) The output emits pulses that represent the mass of Meter 2.
Additivation system 1 (10) Only if the additivation system 1 is used. The data emitted is the same of the preset
Additivation system 2 (11) Only if the additivation system 2 is used. The data emitted is the same of the preset.
Additivation systems 1&2 (12) Only if the additivation system 1or 2 are used. The data emitted is the same of the preset.
FlexiMix (13) Only if FlexiMix is used. The data emitted is the same of the preset.
7.3.3.4.2 Ratio units of measurement/pulses Minimum Maximum Default
It allows to set the ratio between the units measured and pulses to emit. 0,0001 99999,9999 1,0

Page n°98 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.4 Valves 7.4 Valves
7.4.1 Valves of meter 1 7.4.2 Valves of meter 2
DESCRIPTION CODE METER VALUES Protection
Choice regulating valve Two stage (0)
It allows to set the type of “regulating valve” used to open and close the flow of product inside 7.4.1.1 METER 1 Multistep (Default) (1)
the meter during a batch or transaction... Open/Close (2)
Two stage 4-20mA (3)
7.4.2.1 METER 2
Analog 4-20mA (4)

7.4 Valves 7.4 Valves


7.4.1 Valves of meter 1 7.4.2 Valves of meter 2
7.4.1.2 Two stage 7.4.2.2 Two stage
DESCRIPTION CODE METER VALUES Protection
Enable final adjustment 7.4.1.2.1 METER 1 Disabled (Default) (0)
It enables/disables the automatic adjustment to achieve the preset quantity. 7.4.2.2.1 METER 2 Enabled (1)
Minimum Maximum Default
Final adjustment pulse 7.4.1.2.2 METER 1
1 ms 9999 ms 100 ms
Duration of the pulses used to open the valve during the automatic final adjustment... 7.4.2.2.2 METER 2
Final adjustment pause 7.4.1.2.3 METER 1
Duration of the pause between two pulses used to open the valve during the automatic final 1 ms 9999 ms 1000 ms
7.4.2.2.3 METER 2
adjustment.
Low flow 4-20mA value 7.4.1.2.4 METER 1
4,0 mA 20,0 mA 6,0 mA
It allows to set the value of current to open the “Two stage 4-20mA” valve in LF (Low Flow). 7.4.2.2.4 METER 2
High flow 4-20mA value 7.4.1.2.5 METER 1
4,0 mA 20,0 mA 18,0 mA
It allows to set the value of current to open the “Two stage 4-20mA” valve in HF (High Flow). 7.4.2.2.5 METER 2

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°99 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.4 Valve 7.4 Valve
7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.3 Multistep 7.4.2.3 Multistep
VALUES
DESCRIPTION CODE METER Protection
Minimum Maximum Default
Unlock time 7.4.1.3.1 METER 1
Time necessary to open the valve at the ILF (Initial Low Flow) from full close state. 1 99999 500
7.4.2.3.1 METER 2
Low flow rate tolerance 7.4.1.3.2 METER 1
Range of values within the flow rate is accepted. The range is calculated as a percentage of the 0% 100 % 10 %
ILF flow and FLF . 7.4.2.3.2 METER 2
High flow rate tolerance 7.4.1.3.3 METER 1
Range of values within the flow rate is accepted. The range is calculated as a percentage of the 0% 100 % 5%
HF flow 7.4.2.3.3 METER 2
Stabilization delay 7.4.1.3.4 METER 1
Delay time between the end of one valve command (pulse) and the stabilization of the flow rate. 500 ms 9999 ms 1000 ms
7.4.2.3.4 METER 2
Opening speed 7.4.1.3.5 METER 1
It defines the time to open the valve at the maximum flow rate from full close state. To increase 1 ms 99999 ms 1500 ms
the speed, increase the value. 7.4.2.3.5 METER 2
Closing speed 7.4.1.3.6 METER 1
Time necessary to close the valve from the maximum flow rate. To increase the speed, increase 1 ms 99999 ms 1500 ms
the value. 7.4.2.3.6 METER 2
Minimum pulse 7.4.1.3.7 METER 1
Minimum pulse time of the pulse used to drive the valve. 1 ms 999 ms 20 ms
7.4.2.3.7 METER 2
Minimum gain
7.4.1.3.8 METER 1
Minimum flow rate variation after a regulation of valve (pulse). If after some regulations the
0 9999 0
variation is not appreciable, VEGA stops the regulation of the valve until a variation occurs. Set
7.4.2.3.8 METER 2
the value “0” to disable this functionality.
First rising pulse 7.4.1.3.9 METER 1
Percentage of high flow rate that must be reached by the first pulse used to move from ILF 0% 100 % 75 %
(Initial Low Flow) to HF (High Flow). 7.4.2.3.9 METER 2
First falling pulse 7.4.1.3.10 METER 1
Percentage of the instantaneous flow rate that must be reached by the first pulse used to move 0% 100 % 75 %
from HF (High Flow) to FLF (Final Low Flow). 7.4.2.3.10 METER 2
Pulse time of rise ramp 7.4.1.3.11 METER 1
If there isn’t an appreciable increasing of flow rate during first pulse of rise ramp, valve will be set 0 ms 9999 ms 5000 ms
in stabilization phase. 7.4.2.3.11 METER 2
Percentage at max flow rate 7.4.1.3.12 METER 1
Set the opening percentage of valve at maximum flow rate of meter. 0% 100 % 0%
7.4.2.3.12 METER 2

Page n°100 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.4 Valve 7.4 Valve
7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.4 Analog 4-20mA 7.4.2.4 Analog 4-20mA
VALUES
DESCRIPTION CODE METER Protection
Minimum Maximum Default
Unlock time 7.4.1.4.1 METER 1
It allows to set the time necessary to open the valve to the ILF (Initial Low Flow) with the valve 1 99999 500
closed. 7.4.2.4.1 METER 2
mA to unlock 7.4.1.4.2 METER 1
It allows to set the value of current necessary to open the valve to the ILF (Initial Low Flow). 4,0 mA 20,0 mA 5,0 mA
7.4.2.4.2 METER 2
Low flow rate tolerance 7.4.1.4.3 METER 1
Range of values within the flow rate is accepted. The range is calculated as a percentage of the 0% 100 % 10 %
ILF flow and FLF . 7.4.2.4.3 METER 2
High flow rate tolerance 7.4.1.4.4 METER 1
Range of values within the flow rate is accepted. The range is calculated as a percentage of the 0% 100 % 5%
HF flow 7.4.2.4.4 METER 2
Stabilization delay 7.4.1.4.5 METER 1
Delay time between the end of one valve command (pulse) and the stabilization of the flow rate. 500 ms 9999 ms 1000 ms
7.4.2.4.5 METER 2
Minimum variation in mA 7.4.1.4.6 METER 1
Minimum current for every step that VEGA can use to change the flow rate. 0,1 mA Par n° 7.4.1.4.7 0,1 mA
7.4.2.4.6 METER 2
Maximum variation in mA 7.4.1.4.7 METER 1
Maximum current for every step that VEGA can use to change the flow rate. Par n° 7.4.1.4.6 16,0 mA 5,0 mA
7.4.2.4.7 METER 2
mA value of max flow rate 7.4.1.4.8 METER 1
Minimum current to open the valve at the maximum flow rate. 4,0 mA 20,0 mA 20,0 mA
7.4.2.4.8 METER 2

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°101 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.4 Valve 7.4 Valve
7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.5 Line in pressure delay 7.4.2.5 Line in pressure delay
VALUES
DESCRIPTION CODE METER Protection
Minimum Maximum Default
Line in pressure delay 7.4.1.5 METER 1
Delay between the start of product pump and the opening of the preset valve. 0s 99 s 5s
7.4.2.5 METER 2

7.4 Valve 7.4 Valve


7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.6 Final closing quantity 7.4.2.6 Final closing quantity
VALUES
DESCRIPTION CODE METER Protection
Minimum Maximum Default
First flow rate Maximum value of
7.4.1.6.1 METER 1 0,000 0,000
Value of first flow rate used to interpolate final closing quantity. flow rate of meter
If it is set to 0 interpolation will not be done and to close valve will be used “Quantity at first flow Maximum value of
rate” parameter. 7.4.2.6.1 METER 2 0,000 0,000
flow rate of meter
Quantity at first flow rate
7.4.1.6.2 METER 1 0,0000 9999.9999 0,0000
Product quantity that flows after a closing at first flow rate.
7.4.2.6.2 METER 2 0,0000 9999.9999 0,0000
Second flow rate Maximum value of
7.4.1.6.3 METER 1 0,000 0,000
Value of second flow rate used to interpolate final closing quantity. flow rate of meter
Maximum value of
7.4.2.6.3 METER 2 0,000 0,000
flow rate of meter
Quantity at second flow rate
7.4.1.6.4 METER 1 0,0000 9999.9999 0,0000
Product quantity that flows after a closing at second flow rate.
7.4.2.6.4 METER 2 0,0000 9999.9999 0,0000
Third flow rate Maximum value of
7.4.1.6.5 METER 1 0,000 0,000
Value of third flow rate used to interpolate final closing quantity. flow rate of meter
Maximum value of
7.4.2.6.5 METER 2 0,000 0,000
flow rate of meter
Quantity at third flow rate
7.4.1.6.6 METER 1 0,0000 9999.9999 0,0000
Product quantity that flows after a closing at third flow rate.
7.4.2.6.6 METER 2 0,0000 9999.9999 0,0000

Page n°102 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.4 Valve 7.4 Valve
7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.7 Pump delay to switch off 7.4.2.7 Pump delay to switch off
VALUES
DESCRIPTION CODE METER Protection
Minimum Maximum Default
Pump delay to switch off 7.4.1.7 METER 1
Delay between the final closing of preset valve and the switch off of product pump. 0s 99 s 5s
7.4.2.7 METER 2

7.4 Valve 7.4 Valve


7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.8 Block valve closing 7.4.2.8 Block valve closing
DESCRIPTION CODE METER VALUES Protection
Block valve closing 7.4.1.8 METER 1 Batch end(Default) (0)
It defines if the “block valve” will be closed at the end of the batch or at the end of the
transaction. 7.4.2.8 METER 2 Transaction end (1)

7.4 Valve 7.4 Valve


7.4.1 Meter 1 7.4.2 Meter 2
7.4.1.9 Selecting valve closing 7.4.2.9 Selecting valve closing
DESCRIPTION CODE METER VALUES Protection
Selecting valve closing 7.4.1.9 METER 1 Batch end(Default) (0)
It defines if selecting valve has to be closed at the end of batch, at the end of transaction or
never. Transaction end (1)
7.4.1.9 METER 2
Never (2)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°103 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.4 Valve
7.4.1 Meter 1
7.4.1.10 Back-pressure control
DESCRIPTION CODE METER VALUES Protection
Back-pressure enabling Not enabled(Default) (0)
It defines if flow rate has to be reduce using value of pressure acquired. 7.4.1.10.1 METER 1 Fixed back pressure value (1)
Equilibrium pressure value (2)
Fixed back pressure value Minimum Maximum Default
It defines minimum back pressure value granted. 7.4.1.10.2 METER 1
0 1500 5
Flow rate percentage reduction
7.4.1.10.3 METER 1 50% 90% 75%
It defines reduction percentage to apply to observed flow rate.
Delta pressure for flow rate reduction
Pressure value to be summed to equilibrium pressure or fixed back pressure value to establish 7.4.1.10.4 METER 1 0 1500 1
threshold for flow rate reduction.
Delta pressure for flow rate restore
Pressure value to be summed to equilibrium pressure or fixed back pressure value to establish 7.4.1.10.5 METER 1 0 1500 2
threshold for flow rate restore.
Flow rate reduction delay
Delay to start reduction of flow rate when pressure value is less than reduction value. 7.4.1.10.6 METER 1 0s 99 s 5s

Flow rate restore delay


Minimum time of permanency in flow-rate reduce condition before restore nominal flow rate set 7.4.1.10.7 METER 1 0s 99 s 30 s
point.

Page n°104 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.5 Print 7.5.1 Print Configuration
CODE/DESCRIPTION VALUES Protection
7.5.1.1 Type of print End of batch (Default) (0)
It allows to set if the printing of data takes place at the end of each batch or at the end of transaction
End of transaction (1)

7.5.1.2 Page form feed Disabled (Default) (0)


It enables/disables the jump of page at the end of every batch/transaction data printing. Enabled (1)
7.5.1.3 Type of data to print Differential (0)
It defines if VEGA has to print only the data of differential or data of differential, meter 1 and meter 2 products. Differential & products (Default) (1)
7.5.1.4 Label for mass/weight Mass
It defines if the label for weight data must be printed with “Mass” or “Weight”. Weight (Default)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°105 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.5 Print 7.5.2 Data of Differential
DESCRIPTION DATA CODE DATA DESCRIPTION VALUES Protection
It allows to choose which data has to be 1 7.5.2.1 TEST OF PRINT Disabled (Default) (0) Enabled (1)
printed for differential. 2 7.5.2.2 LEGALLY MEASUREMENT NUMBER Disabled (0) Enabled (Default) (1)
3 7.5.2.3 TRANSACTION NUMBER Disabled (0) Enabled (Default) (1)
NOTE: 4 7.5.2.4 BATCH NUMBER Disabled (0) Enabled (Default) (1)
The printer has to be connected at one of
5 7.5.2.5 PIN CODE/BADGE Disabled (Default) (0) Enabled (1)
the serial lines (See Installation Manual)
6 7.5.2.6 R.C.E. CODE Disabled (Default) (0) Enabled (1)
and VEGA must be programmed to
communicate with the printer. 7 7.5.2.7 VEGA POSITION Disabled (0) Enabled (Default) (1)
8 7.5.2.8 VEGA SERIAL NUMBER Disabled (0) Enabled (Default) (1)
9 7.5.2.9 METER 1 SERIAL NUMBER Disabled (0) Enabled (Default) (1)
10 7.5.2.10 METER 2 SERIAL NUMBER Disabled (0) Enabled (Default) (1)
11 7.5.2.11 DATE AND TIME OF DELIVERY END OF TRANSACTION OR BATCH Disabled (0) Enabled (Default) (1)
12 7.5.2.12 DATE AND TIME OF DELIVERY START OF TRANSACTION OR BATCH Disabled (0) Enabled (Default) (1)
13 7.5.2.13 PRODUCT NAME Disabled (0) Enabled (Default) (1)
14 7.5.2.14 PRESET QUANTITY Disabled (0) Enabled (Default) (1)
15 7.5.2.15 FINAL GROSS VOLUME TOTALIZER Disabled (0) Enabled (Default) (1)
16 7.5.2.16 INITIAL GROSS VOLUME TOTALIZER Disabled (0) Enabled (Default) (1)
17 7.5.2.17 GROSS VOLUME DELIVERED Disabled (0) Enabled (Default) (1)
18 7.5.2.18 FINAL GROSS STANDARD VOLUME TOTALIZER Disabled (Default) (0) Enabled (1)
19 7.5.2.19 INITIAL GROSS STANDARD VOLUME TOTALIZER Disabled (Default) (0) Enabled (1)
20 7.5.2.20 GROSS STANDARD VOLUME DELIVERED Disabled (Default) (0) Enabled (1)
21 7.5.2.21 FINAL MASS TOTALIZER Disabled (0) Enabled (Default) (1)
22 7.5.2.22 INITIAL MASS TOTALIZER Disabled (0) Enabled (Default) (1)
23 7.5.2.23 MASS DELIVERED Disabled (0) Enabled (Default) (1)
24 7.5.2.24 AVERAGE FLOW RATE Disabled (0) Enabled (Default) (1)
25 7.5.2.25 AVERAGE TEMPERATURE Disabled (0) Enabled (Default) (1)
26 7.5.2.26 VOLUME THERMAL CONVERSION METHOD Disabled (0) Enabled (Default) (1)
27 7.5.2.27 AVERAGE ALPHA/STRENGTH Disabled (Default) (0) Enabled (1)
28 7.5.2.28 AVERAGE BASE DENSITY Disabled (0) Enabled (Default) (1)
29 7.5.2.29 AVERAGE OBSERVED DENSITY Disabled (0) Enabled (Default) (1)
30 7.5.2.30 AVERAGE PRESSURE Disabled (0) Enabled (Default) (1)
31 7.5.2.31 ADDITIVATION RECIPE Disabled (Default) (0) Enabled (1)
32 7.5.2.32 VOLUME OF ADDITIVES INJECTED Disabled (Default) (0) Enabled (1)
33 7.5.2.33 MASS OF ADDITIVES INJECTED Disabled (Default) (0) Enabled (1)

Page n°106 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
7.5 Print 7.5.3 Data of Meter 1 7.5.4 Data of Meter 2

CODE
DESCRIPTION DATA DATA DESCRIPTION VALUES Protection
Meter 1 Meter 2
It allows to choose which data has to be 1 7.5.3.1 7.5.4.1 PRODUCT NAME Disabled (0) Enabled (Default) (1)
printed for meter. 2 7.5.3.2 7.5.4.2 FINAL GROSS VOLUME TOTALIZER Disabled (0) Enabled (Default) (1)
3 7.5.3.3 7.5.4.3 INITIAL GROSS VOLUME TOTALIZER Disabled (0) Enabled (Default) (1)
NOTE: 4 7.5.3.4 7.5.4.4 GROSS VOLUME DELIVERED Disabled (0) Enabled (Default) (1)
The printer has to be connected at one of 5 7.5.3.5 7.5.4.5 FINAL GROSS STANDARD VOLUME TOTALIZER Disabled (Default) (0) Enabled (1)
the serial lines (See Installation Manual)
6 7.5.3.6 7.5.4.6 INITIAL GROSS STANDARD VOLUME TOTALIZER Disabled (Default) (0) Enabled (1)
and VEGA must be programmed to
communicate with the printer. 7 7.5.3.7 7.5.4.7 GROSS STANDARD VOLUME DELIVERED Disabled (Default) (0) Enabled (1)
8 7.5.3.8 7.5.4.8 FINAL MASS TOTALIZER Disabled (0) Enabled (Default) (1)
9 7.5.3.9 7.5.4.9 INITIAL MASS TOTALIZER Disabled (0) Enabled (Default) (1)
10 7.5.3.10 7.5.4.10 MASS DELIVERED Disabled (0) Enabled (Default) (1)
11 7.5.3.11 7.5.4.11 AVERAGE FLOW RATE Disabled (0) Enabled (Default) (1)
12 7.5.3.12 7.5.4.12 AVERAGE TEMPERATURE Disabled (0) Enabled (Default) (1)
13 7.5.3.13 7.5.4.13 VOLUME THERMAL CONVERSION METHOD Disabled (0) Enabled (Default) (1)
14 7.5.3.14 7.5.4.14 AVERAGE ALPHA/STRENGTH Disabled (Default) (0) Enabled (1)
15 7.5.3.15 7.5.4.15 AVERAGE BASE DENSITY Disabled (0) Enabled (Default) (1)
16 7.5.3.16 7.5.4.16 AVERAGE OBSERVED DENSITY Disabled (0) Enabled (Default) (1)
17 7.5.3.17 7.5.4.17 AVERAGE PRESSURE Disabled (0) Enabled (Default) (1)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°107 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
7.6 LFD-6 display
7.6.1 LFD-6 1 7.6.2 LFD-6 2
CODE/DESCRIPTION VALUES Protection
Data shown on LFD-6 No one (0)
Select which data has to be shown on the external LFD-6 display. Gross volume (Default) (1)
Gross standard volume (2)
Mass (3)
Flow rate (4)
Preset in decreasing (5)
Decimals used on LFD-6 3 decimals (0)
Select how many decimals will be shown on external LFD-6 display. 2 decimals (1)
1 decimal (Default) (2)
0 decimals (3)
Data of batch or sum of batches Single batch (Default) (0)
Select if showed data is related to the single batch or sum of batches. Sum of batches (1)
Data Meter 1 (0)
Select which meter is refer the data that has to be shown on external LFD-6 display. Meter 2 (1)
Differential (Default) (2)

7.7 Gas extractor


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
7.7.1 Delay (LF)
Delay in seconds before opening the valve in high flow.
0 100 0

7.7.2 Delay (STOP)


0 100 0
Delay in seconds before opening the valve.

Page n°108 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
8 ADDITIVATION

8.1 General 8.1.1 Management


CODE/DESCRIPTION VALUES Protection
8.1.1.1 Enabling (Local) Never (Default) (0)
It allows to set if and when the additivation is enabled during delivery operations in Local mode. Always (1)
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed. By request (2)
8.1.1.2 Alarm/Timeout
It allows to set if the alarms of additivation must be checked always or only during the additivation phase. During additivation (Default) (0)

The alarms “Leak of additive” and “Additive out of tolerance” are always checked.
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed.
Always (1)

8.1 General 8.1.2 Unit of measurement


CODE/DESCRIPTION VALUES Protection
8.1.2.1 Volume/mass
cc / g (Default) (0)
It allows to choose the unit of measurement of the additive.

Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed. L / Kg (1)

8.1.2.2 Ppm reference


Mass (grams) (0)
It allows to choose if the ppm (parts per million) of additive are computed in volume or in mass.

Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed. Volume (Default) (1)

8.1 General 8.1.3 Displays


CODE/DESCRIPTION VALUES Protection
8.1.3 Displays Peso (0)
Specifies if the additive quantity should be displayed in volume, mass or both. It is also possible to display the flow rate of additive.
The flow rate is available only for the additives managed as “metered injection” (see par. 8.4.1, 8,5.1, 8.6.1, 8.7.1, 8.8.1, 8.9.1) Volume (1)

Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure Volume e peso (Default) (2)
switch is removed.

8.1 General 8.1.4 Quantity of cleaning line


CODE/DESCRIPTION VALUES Protection
8.1.4 Quantity of cleaning line Minimum Maximum Default
Quantity of main product remaining to deliver when the injection of additives is completed. 0 99999 100

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°109 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
8.2 Recipes 8.2.1 Management
CODE/DESCRIPTION VALUES Protection
8.2.1.1 Recipes number Minimum Maximum Default
It defines how many recipes can be used to additize a batch. Every recipe can be composed with one or more additives. See note
1 4 1
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed.

8.2 Recipes 8.2.2 Recipe 1


CODE/DESCRIPTION VALUES Protection
8.2.2.1 Name of recipe Minimum Maximum Default
It allows to set a name for the first recipe. Maximum 10 alphanumeric characters.
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed.
0 10 RECIPE 1
8.2.2.2 Additives quantities CODE ADDITIVE Minimum Maximum Default Protection
Parts per million (ppm) of additives A, B, C, D, E, F that have to be injected during a batch. . 8.2.2.2.1 Additive A 0 999999 0 See par. 8.4.2
For example, if the quantity delivered is 1.000 Litres and this parameter is set to “100 ppm” the 8.2.2.2.2 Additive B 0 999999 0 See par. 8.5.2
injected quantity will be (1000 litres/1.000.000) x 100=100cc. 8.2.2.2.3 Additive C 0 999999 0 See par. 8.6.2
8.2.2.2.4 Additive D 0 999999 0 See par. 8.7.2
8.2.2.2.5 Additive E 0 999999 0 See par. 8.8.2
8.2.2.2.6 Additive F 0 999999 0 See par. 8.9.2
8.2.2.3 Outputs for recipe CODE OUTPUT Minimum Maximum Default
Outputs used to manage an external smart additive system. 8.2.2.3.1 Additive selection 1 ON OFF OFF
It is also necessary to set the corresponding outputs in the parameters “7.3 - Outputs”. 8.2.2.3.2 Additive selection 2 ON OFF OFF
For example, to enable the additive system 1 you have to:
8.2.2.3.3 Additive selection 3 ON OFF OFF
 Set the parameter (e.g.) 7.3.2.9 = “Enabling of additivation system 1”
 Set the parameter 8.2.2.3.5 = “ON” 8.2.2.3.4 Additive selection 4 ON OFF OFF
Enable of additivation
8.2.2.3.5 ON OFF OFF
system 1
Enable of additivation
8.2.2.3.6 ON OFF OFF
system 2

Page n°110 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
8.2 Recipes 8.2.3 Recipe 2
CODE/DESCRIPTION VALUES Protection
8.2.3.1 Name of recipe Minimum Maximum Default
It allows to set a name for the second recipe. Maximum 10 alphanumeric characters.
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed.
0 10 RECIPE 2
8.2.3.2 Additives quantities CODE ADDITIVE Minimum Maximum Default Protection
Parts per million (ppm) of additives A, B, C, D, E, F that have to be injected during a batch. . 8.2.3.2.1 Additive A 0 999999 0 See par. 8.4.2
For example, if the quantity delivered is 1.000 Litres and this parameter is set to “100 ppm” the 8.2.3.2.2 Additive B 0 999999 0 See par. 8.5.2
injected quantity will be (1000 litres/1.000.000) x 100=100cc. 8.2.3.2.3 Additive C 0 999999 0 See par. 8.6.2
8.2.3.2.4 Additive D 0 999999 0 See par. 8.7.2
8.2.3.2.5 Additive E 0 999999 0 See par. 8.8.2
8.2.3.2.6 Additive F 0 999999 0 See par. 8.9.2
8.2.3.3 Outputs for recipe CODE OUTPUT Minimum Maximum Default
Outputs used to manage an external smart additive system. 8.2.3.3.1 Additive selection 1 ON OFF OFF
It is also necessary to set the corresponding outputs in the parameters “7.3 - Outputs”. 8.2.3.3.2 Additive selection 2 ON OFF OFF
For example, to enable the additive system 1 you have to:
8.2.3.3.3 Additive selection 3 ON OFF OFF
 Set the parameter (e.g.) 7.3.2.9 = “Enabling of additivation system 1”
 Set the parameter 8.2.3.3.5 = “ON” 8.2.3.3.4 Additive selection 4 ON OFF OFF
8.2.3.3.5 Enable of additivation
ON OFF OFF
system 1
8.2.3.3.6 Enable of additivation
ON OFF OFF
system 2

8.2 Recipes 8.2.4 Recipe 3


CODE/DESCRIPTION VALUES Protection
8.2.4.1 Name of recipe Minimum Maximum Default
It allows to set a name for the second recipe. Maximum 10 alphanumeric characters.
0 10 RECIPE 3
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed.
8.2.4.2 Additives quantities CODE ADDITIVE Minimum Maximum Default Protection
Parts per million (ppm) of additives A, B, C, D, E, F that have to be injected during a batch. . 8.2.4.2.1 Additive A 0 999999 0 See par. 8.4.2
For example, if the quantity delivered is 1.000 Litres and this parameter is set to “100 ppm” the 8.2.4.2.2 Additive B 0 999999 0 See par. 8.5.2
injected quantity will be (1000 litres/1.000.000) x 100=100cc. 8.2.4.2.3 Additive C 0 999999 0 See par. 8.6.2
8.2.4.2.4 Additive D 0 999999 0 See par. 8.7.2
8.2.4.2.5 Additive E 0 999999 0 See par. 8.8.2
8.2.4.2.6 Additive F 0 999999 0 See par. 8.9.2
8.2.4.3 Outputs for recipe CODE OUTPUT Minimum Maximum Default
Outputs used to manage an external smart additive system. 8.2.4.3.1 Additive selection 1 ON OFF OFF
It is also necessary to set the corresponding outputs in the parameters “7.3 - Outputs”. 8.2.4.3.2 Additive selection 2 ON OFF OFF
For example, to enable the additive system 1 you have to:
8.2.4.3.3 Additive selection 3 ON OFF OFF
 Set the parameter (e.g.) 7.3.2.9 = “Enabling of additivation system 1”
 Set the parameter 8.2.3.3.5 = “ON” 8.2.4.3.4 Additive selection 4 ON OFF OFF
8.2.4.3.5 Enable of additivation
ON OFF OFF
system 1
8.2.4.3.6 Enable of additivation
ON OFF OFF
system 2

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°111 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
8.2 Recipes 8.2.5 Recipe 4
CODE/DESCRIPTION VALUES Protection
8.2.5.1 Name of recipe Minimum Maximum Default
It allows to set a name for the second recipe. Maximum 10 alphanumeric characters.
0 10 RECIPE 4
Note: If one of these parameters: 8.4.2, 8.5.2, 8.6.2, 8.7.2, 8.8.2, 8.9.2 is enabled, this parameter will be modifiable only if Weight & Measure switch is removed.
8.2.5.2 Additives quantities CODE ADDITIVE Minimum Maximum Default Protection
Parts per million (ppm) of additives A, B, C, D, E, F that have to be injected during a batch. . 8.2.5.2.1 Additive A 0 999999 0 See par. 8.4.2
For example, if the quantity delivered is 1.000 Litres and this parameter is set to “100 ppm” the 8.2.5.2.2 Additive B 0 999999 0 See par. 8.5.2
injected quantity will be (1000 litres/1.000.000) x 100=100cc. 8.2.5.2.3 Additive C 0 999999 0 See par. 8.6.2
8.2.5.2.4 Additive D 0 999999 0 See par. 8.7.2
8.2.5.2.5 Additive E 0 999999 0 See par. 8.8.2
8.2.5.2.6 Additive F 0 999999 0 See par. 8.9.2
8.2.5.3 Outputs for recipe CODE OUTPUT Minimum Maximum Default
Outputs used to manage an external smart additive system. 8.2.5.3.1 Additive selection 1 ON OFF OFF
It is also necessary to set the corresponding outputs in the parameters “7.3 - Outputs”. 8.2.5.3.2 Additive selection 2 ON OFF OFF
For example, to enable the additive system 1 you have to:
8.2.5.3.3 Additive selection 3 ON OFF OFF
 Set the parameter (e.g.) 7.3.2.9 = “Enabling of additivation system 1”
 Set the parameter 8.2.3.3.5 = “ON” 8.2.5.3.4 Additive selection 4 ON OFF OFF
8.2.5.3.5 Enable of additivation
ON OFF OFF
system 1
8.2.5.3.6 Enable of additivation
ON OFF OFF
system 2

8.3 FlexiMix
VALUES
DESCRIPTION CODE FLEXIMIX Protection
Minimum Maximum Default
8.3.1 Serial addresses 8.3.1.1 FlexiMix 1 0 247 1
VEGA allows to additize the main product with a maximum of six additives. In the versions of VEGA with ‘integrated
additivation system’, additives A and B can also be managed directly by VEGA while the rest can be delegated to the 8.3.1.2 FlexiMix 2 0 247 2
smart additive system “FlexiMix”.
8.3.1.3 FlexiMix 3 0 247 3
Considering that FlexiMix can manage up to a maximum of six additives, it is possible to associate all the six additives to
only one FlexiMix or potentially to different FlexiMixes, depending on your needs (See parameters n.8.4.5.1, 8.5.5.1,
8.3.1.4 FlexiMix 4 0 247 4
8.6.5.1, 8.7.5.1, 8.8.5.1 and 8.9.5.1).
FlexiMix performs the additivation based on the information received from VEGA by the serial communication line 8.3.1.5 FlexiMix 5 0 247 5
(RS485). If there are more FlexiMixes connected to the same line, it is necessary to address the messages to the right
FlexiMix. For this reason, on both VEGA and FlexiMix must be set the correct address number. 8.3.1.6 FlexiMix 6 0 247 6

Page n°112 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
8.4 Additive A 8.4.1 Management
CODE/DESCRIPTION VALUES Protection
8.4.1.1 Additive management Disabled (Default) (0) See par
It allows to enable or disable the management of this additive by choosing the type of additive system. FlexiMix (1) n. 8.4.2
8.4.1.2 Product to additize Differential (Default) (0)
It defines if the additive is for differential or for one of the Meters. See par
Meter 1 (1)
n. 8.4.2
Meter 2 (2)

8.4 Additive A
CODE/DESCRIPTION VALUES Protection
8.4.2 Parameters protection Disabled (Default) (0)
It allows to choose if the additive parameters, having influence on the measure, should be protected by the Weight & Measure switch. Enabled (1)

8.4 Additive A
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.4.3 Additive name See par
0 Characters 7 Characters ADD. A
It allows to personalize the name of additive A. n. 8.4.2

8.4 Additive A
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.4.4 Additive density See par
0,1 99999,9 1000,0
Density of the additive used by VEGA to calculate the mass. Mass = Volume * Density n. 8.4.2

8.4 Additive A
CODE/DESCRIPTION VALUES Protection
8.4.5 FlexiMix FlexiMix 1 (default) (0)
If the parameter 8.4.1.1 is set to “FlexiMix” it allows to choose which FlexiMix manages this additive. FlexiMix 2 (1)
FlexiMix 3 (2)
FlexiMix 4 (3)
FlexiMix 5 (4)
FlexiMix 6 (5)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°113 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
8.5 Additive B 8.5.1 Management
CODE/DESCRIPTION VALUES Protection
8.5.1.1 Additive management Disabled (Default) (0) See par
It allows to enable or disable the management of this additive by choosing the type of additive system. FlexiMix (1) n. 8.5.2
8.5.1.2 Product to additize Differential (Default) (0)
It defines if the additive is for differential or for one of the Meters. See par
Meter 1 (1)
n. 8.5.2
Meter 2 (2)

8.5 Additive B
CODE/DESCRIPTION VALUES Protection
8.5.2 Parameters protection Disabled (Default) (0)
It allows to choose if the additive parameters, having influence on the measure, should be protected by the Weight & Measure switch. Enabled (1)

8.5 Additive B
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.5.3 Additive name See par
0 Characters 7 Characters ADD. B
It allows to personalize the name of additive B. n. 8.5.2

8.5 Additive B
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.5.4 Additive density See par
0,1 99999,9 1000,0
Density of the additive used by VEGA to calculate the mass. Mass = Volume * Density n. 8.5.2

8.5 Additive B
CODE/DESCRIPTION VALUES Protection
8.5.5 FlexiMix FlexiMix 1 (default) (0)
If the parameter 8.5.1.1 is set to “FlexiMix” it allows to choose which FlexiMix manages this additive. FlexiMix 2 (1)
FlexiMix 3 (2)
FlexiMix 4 (3)
FlexiMix 5 (4)
FlexiMix 6 (5)

Page n°114 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
8.6 Additive C 8.5.1 Management
CODE/DESCRIPTION VALUES Protection
8.6.1.1 Additive management Disabled (Default) (0) See par
It allows to enable or disable the management of this additive by choosing the type of additive system. FlexiMix (1) n. 8.6.2
8.6.1.2 Product to additize Differential (Default) (0)
It defines if the additive is for differential or for one of the Meters. See par
Meter 1 (1)
n. 8.6.2
Meter 2 (2)

8.6 Additive C
CODE/DESCRIPTION VALUES Protection
8.6.2 Parameters protection Disabled (Default) (0)
It allows to choose if the additive parameters, having influence on the measure, should be protected by the Weight & Measure switch. Enabled (1)

8.6 Additive C
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.6.3 Additive name See par
0 Characters 7 Characters ADD. C
It allows to personalize the name of additive C. n. 8.6.2

8.6 Additive C
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.6.4 Additive density See par
0,1 99999,9 1000,0
Density of the additive used by VEGA to calculate the mass. Mass = Volume * Density n. 8.6.2

8.6 Additive C
CODE/DESCRIPTION VALUES Protection
8.6.5 FlexiMix FlexiMix 1 (default) (0)
If the parameter 8.6.1.1 is set to “FlexiMix” it allows to choose which FlexiMix manages this additive. FlexiMix 2 (1)
FlexiMix 3 (2)
FlexiMix 4 (3)
FlexiMix 5 (4)
FlexiMix 6 (5)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°115 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
8.7 Additive D 8.5.1 Management
CODE/DESCRIPTION VALUES Protection
8.7.1.1 Additive management Disabled (Default) (0) See par
It allows to enable or disable the management of this additive by choosing the type of additive system. FlexiMix (1) n. 8.7.2
8.7.1.2 Product to additize Differential (Default) (0)
It defines if the additive is for differential or for one of the Meters. See par
Meter 1 (1)
n. 8.7.2
Meter 2 (2)

8.7 Additive D
CODE/DESCRIPTION VALUES Protection
8.7.2 Parameters protection Disabled (Default) (0)
It allows to choose if the additive parameters, having influence on the measure, should be protected by the Weight & Measure switch. Enabled (1)

8.7 Additive D
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.7.3 Additive name See par
0 Characters 7 Characters ADD. D
It allows to personalize the name of additive D. n. 8.7.2

8.7 Additive D
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.7.4 Additive density See par
0,1 99999,9 1000,0
Density of the additive used by VEGA to calculate the mass. Mass = Volume * Density n. 8.7.2

8.7 Additive D
CODE/DESCRIPTION VALUES Protection
8.7.5 FlexiMix FlexiMix 1 (default) (0)
If the parameter 8.7.1.1 is set to “FlexiMix” it allows to choose which FlexiMix manages this additive. FlexiMix 2 (1)
FlexiMix 3 (2)
FlexiMix 4 (3)
FlexiMix 5 (4)
FlexiMix 6 (5)

Page n°116 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
8.8 Additive E 8.8.1 Management
CODE/DESCRIPTION VALUES Protection
8.8.1.1 Additive management Disabled (Default) (0) See par
It allows to enable or disable the management of this additive by choosing the type of additive system. FlexiMix (1) n. 8.8.2
8.8.1.2 Product to additize Differential (Default) (0)
It defines if the additive is for differential or for one of the meter. See par
Meter 1 (1)
n. 8.8.2
Meter 2 (2)

8.8 Additive E
CODE/DESCRIPTION VALUES Protection
8.8.2 Parameters protection Disabled (Default) (0)
It allows to choose if the additive parameters, having influence on the measure, should be protected by the Weight & Measure switch. Enabled (1)

8.8 Additive E
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.8.3 Additive name See par
0 Characters 7 Characters ADD. E
It allows to personalize the name of additive E. n. 8.8.2

8.8 Additive E
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.8.4 Additive density See par
0,1 99999,9 1000,0
Density of the additive used by VEGA to calculate the mass. Mass = Volume * Density n. 8.8.2

8.8 Additive E
CODE/DESCRIPTION VALUES Protection
8.8.5 FlexiMix FlexiMix 1 (default) (0)
If the parameter 8.8.1.1 is set to “FlexiMix” it allows to choose which FlexiMix manages this additive. FlexiMix 2 (1)
FlexiMix 3 (2)
FlexiMix 4 (3)
FlexiMix 5 (4)
FlexiMix 6 (5)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°117 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
8.9 Additive F 8.9.1 Management
CODE/DESCRIPTION VALUES Protection
8.9.1.1 Additive management Disabled (Default) (0) See par
It allows to enable or disable the management of this additive by choosing the type of additive system. FlexiMix (1) n. 8.9.2
8.9.1.2 Product to additize Differential (Default) (0)
It defines if the additive is for differential or for one of the Meters. See par
Meter 1 (1)
n. 8.9.2
Meter 2 (2)

8.9 Additive F
CODE/DESCRIPTION VALUES Protection
8.9.2 Parameters protection Disabled (Default) (0)
It allows to choose if the additive parameters, having influence on the measure, should be protected by the Weight & Measure switch. Enabled (1)

8.9 Additive F
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.9.3 Additive name See par
0 characters 7 characters ADD. F
It allows to personalize the name of additive F. n. 8.9.2

8.9 Additive F
VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
8.9.4 Additive density See par
0,1 99999,9 1000,0
Density of the additive used by VEGA to calculate the mass. Mass = Volume * Density n. 8.9.2

8.9 Additive F
CODE/DESCRIPTION VALUES Protection
8.9.5 FlexiMix FlexiMix 1 (default) (0)
If the parameter 8.9.1.1 is set to “FlexiMix” it allows to choose which FlexiMix manages this additive. FlexiMix 2 (1)
FlexiMix 3 (2)
FlexiMix 4 (3)
FlexiMix 5 (4)
FlexiMix 6 (5)

Page n°118 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.


PROGRAMMING PARAMETERS
Code MA/0721/02/EN/01 dated 05/2018 Reproduction of this document in any form is strictly prohibited by law.
9 DIFFERENTIAL

9.1 Configuration 9.1.1 Flow rates


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
9.1.1.1 Initial low flow rate Minimum flow Maximum flow
300.000
It defines differential flow-rates to reach during the phase of Initial low flow. rate of meters rate of meters
Minimum Maximum Default
9.1.1.2 High flow rate Minimum flow Maximum flow
1800.000
It defines differential flow-rates to reach during the phase of High flow. rate of meters rate of meters
Minimum Maximum Default
9.1.1.3 Final flow rate Minimum flow Maximum flow
300.000
It defines differential flow-rates to reach during the phase of Final low flow. rate of meters rate of meters

9.1 Configuration 9.1.2 Initial low flow quantity


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
9.1.2.1 Percentage of preset
Quantity during initial low flow phase. The value is calculated as percentage of preset value.
0% 100 % 0%
For example: Preset=1000 par.=10% Value = 1000/100*10=100
This parameter will be used if greater than the next parameter and different from 0.
Minimum Maximum Default
9.1.2.2 Fixed quantity
0,000 99999,999 100,000
Quantity in Initial low flow that has to be delivered before going in high flow phase.

9.1 Configuration 9.1.3 Final low flow quantity


VALUES
CODE/DESCRIPTION Protection
Minimum Maximum Default
9.1.3.1 Percentage of preset
Quantity during final low flow phase. The value is calculated as percentage of preset value.
0% 100 % 0%
For example: Preset=1000 par.=10% Value = 1000/100*10=100
- This parameter will be used if greater than the next parameter and different from 0.
Minimum Maximum Default
9.1.3.2 Fixed quantity
0,000 99999,999 200,000
Quantity in final low flow that has to be delivered.

9.2 Differential 1 9.3 Differential 2 9.4 Differential 3


9.2.1 Protection 9.3.1 Protection 9.4.1 Protection
CODE/DESCRIPTION VALUES Protection
Protection Disabled (Default) (0)
If enabled, VEGA will ask to remove weigh & measure switch to modify the parameters. Enabled (1)

COPYRIGHT: ISOIL IMPIANTI S.p.A. Page n°119 of 120


PROGRAMMING PARAMETERS
Reproduction of this document in any form is strictly prohibited by law. Code MA/0721/02/EN/01 dated 05/2018
9.2 Differential 1 9.3 Differential 2 9.4 Differential 3
9.2.2 Composition 9.3.2 Composition 9.4.2 Composition
PARAMETER
DESCRIPTION VALUES Protection
CODE DIFFERENTIAL
Product of Meter 1 9.2.2.1 DIFFERENTIAL 1 Product 1 (Default) (0) Par. 9.2.1
It allows to select the product of Meter 1 for the Differential. 9.3.2.1 DIFFERENTIAL 2 Product 2 (1) Par. 9.3.1
9.4.2.1 DIFFERENTIAL 3 Product 3 (2) Par. 9.4.1

Product of Meter 2 9.2.2.3 DIFFERENTIAL 1 Product 1 (Default) (0) Par. 9.2.1


It allows to select the product of Meter 2 for the Differential. 9.3.2.3 DIFFERENTIAL 2 Product 2 (1) Par. 9.3.1
9.4.2.3 DIFFERENTIAL 3 Product 3 (2) Par. 9.4.1

9.2 Differential 1 9.3 Differential 2 9.4 Differential 3


9.2.4 Additivation recipe 9.3.4 Additivation recipe 9.4.4 Additivation recipe
CODE/DESCRIPTION VALUES Protection
Additivation recipe No one (Default) (0)
In local mode it defines which additivation recipe is associated to differential measurement. Recipe 1 (1)
Recipe 2 (2)
Recipe 3 (3)
Recipe 4 (4)

Page n°120 of 120 COPYRIGHT: ISOIL IMPIANTI S.p.A.