PRODUCT-DETAILS

AF370-40-11-13
AF370-40-11-13 Contactor

General Information
Extended Product Type AF370-40-11-13

Product ID 1SFL607102R1311

EAN 7320500504390

Catalog Description AF370-40-11-13 Contactor

A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-
Long Description pass and Distribution application up to max 1000 V. Operated with wide control voltage
range 100-250 V, 50/60 Hz and DC

Classifications
Object Classification Code Q

ETIM 4 EC000066 - Magnet contactor, AC-switching

ETIM 5 EC000066 - Magnet contactor, AC-switching

ETIM 6 EC000066 - Power contactor, AC switching

ETIM 7 EC000066 - Power contactor, AC switching

IDEA Granular Category 4755 >> Contactors


Code (IGCC)

E-Number (Norway) 4117791

E-Number (Sweden) 3210348


AF370-40-11-13 2

Container Information
Package Level 1 Units box 1 piece

Package Level 1 Width 212 mm

Package Level 1 Depth / 262 mm


Length

Package Level 1 Height 212 mm

Package Level 1 Gross 6.4 kg


Weight

Package Level 1 EAN 7320500504390

Certificates and Declarations (Document Number)


ABS Certificate 14-LD1092198-PDA

BV Certificate BV_36353_A0BV

CB Certificate SE-89316

CCC Certificate CQC_2014010304676670

cUL Certificate 20140910-E73397

Declaration of Conformity 2CMT2015-005439


- CE

DNV GL Certificate DNV_E-14043

EAC Certificate 9AKK107046A8618

Instructions and Manuals 1SFC101066M0201

LR Certificate LR_14_70011(E1)

PRS Certificate TE_2092_880423_16

RINA Certificate ELE060313XG_002

RMRS Certificate 9AKK107045A6978

RoHS Information 2CMT2015-005439

Technical UL/CSA
Maximum Operating Main Circuit 600 V
Voltage UL/CSA

General Use Rating (600 V AC) 420 A


UL/CSA

Environmental
Ambient Air Temperature Close to Contactor for Storage -40 ... +70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C

Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C

Maximum Operating 3000 m


Altitude Permissible

RoHS Status Following EU Directive 2011/65/EU

Technical
Number of Main Contacts 4
NO

Number of Main Contacts 0


AF370-40-11-13 3

NC

Number of Auxiliary 1
Contacts NO

Number of Auxiliary 1
Contacts NC

Rated Operational Voltage Main Circuit 1000 V

Rated Frequency (f) Main Circuit 50 Hz

Conventional Free-air acc. to IEC 60947-4-1, Open Contactors q = 40 °C 525 A


Thermal Current (I th )

Rated Operational Current (1000 V) 40 °C 400 A


AC-1 (I e ) (1000 V) 60 °C 350 A
(1000 V) 70 °C 290 A
(690 V) 40 °C 525 A
(690 V) 60 °C 425 A
(690 V) 70 °C 350 A

Rated Operational Current (220 / 230 / 240 V) 55 °C 370 A


AC-3 (I e ) (380 / 400 V) 55 °C 370 A
(415 V) 55 °C 370 A
(440 V) 55 °C 370 A

Rated Operational Power (220 / 230 / 240 V) 110 KWT


AC-3 (P e ) (380 / 400 V) 200 KWT
(415 V) 200 KWT
(440 V) 200 KWT

Rated Breaking Capacity 8 x Ie AC-3


AC-3 acc. to IEC 60947-4-
1

Rated Making Capacity 10 x Ie AC-3


AC-3 acc. to IEC 60947-4-
1

Short-Circuit Protective gG Type Fuses 630 A


Devices

Rated Short-time at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A
Withstand Current (I cw ) at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A

Maximum Breaking cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A
Capacity

Maximum Electrical AC-1 300 cycles per hour


Switching Frequency

Rated Insulation Voltage acc. to UL/CSA 600 V


(U i ) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

Rated Impulse Withstand Main Circuit 8 kV


Voltage (U imp )

Mechanical Durability 5 million

Maximum Mechanical 300 cycles per hour


Switching Frequency

Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)

Rated Control Circuit 50 Hz 100 ... 250 V


Voltage (U c ) 60 Hz 100 ... 250 V
DC Operation 100 ... 250 V

Coil Consumption Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 4.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 410 W

Operate Time Between Coil De-energization and NO Contact Opening 45 ... 80 ms


Between Coil Energization and NO Contact Closing 30 ... 60 ms
AF370-40-11-13 4

Connecting Capacity Main Flexible 2 x 70 ... 185 m²


Circuit Rigid Al-Cable 1 x 185 ... 240 m²
Rigid Cu-Cable 1 x 6 ... 300 m²

Connecting Capacity Flexible with Ferrule 1x 0.75 ... 2.5


Auxiliary Circuit Flexible with Insulated Ferrule 2x 0.75 ... 2.5
Flexible 2x0.75 ... 2.5 m²
Solid 2 x 1 ... 4 m²
Stranded 2 x 1 .... 4 m²

Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type Main Circuit: Bars

Dimensions
Product Net Width 184 mm

Product Net Depth / 180 mm


Length

Product Net Height 225 mm

Product Net Weight 5.7 kg

Popular Downloads
Data Sheet, Technical 1SBC100192C0206
Information

Instructions and Manuals 1SFC101066M0201

Ordering
Minimum Order Quantity 1 piece

Customs Tariff Number 85364900

Categories

Low Voltage Products and Systems → Control Products → Contactors → Block Contactors