0% found this document useful (0 votes)
7 views6 pages

Data Sheet 3LD2103-1TL53: Model

Uploaded by

MomoMarouf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views6 pages

Data Sheet 3LD2103-1TL53: Model

Uploaded by

MomoMarouf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Data sheet 3LD2103-1TL53

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 4- pole, Iu:


25 A, operating power / at AC-23 A 400 V: 9.5 kW, front-mounted, rotary operating
mechanism, Red / yellow, 4-hole mounting of the handle

Model
product brand name SENTRON
product designation Switch disconnector
design of the product EMERGENCY-STOP switch
display version for switch position indicator manual operation 1 ON - 0 OFF
type of switch front mounted
design of the actuating element Short rotary knob
color of the actuating element red
design of handle rotary operating mechanism, red/yellow
type of the driving mechanism motor drive No
General technical data
number of poles 4
size of switch disconnector 2
mechanical service life (operating cycles) typical 100 000
electrical endurance (operating cycles)
● at AC-23 A at 690 V 6 000
operating frequency maximum 50 1/h
degree of pollution 3
Voltage
insulation voltage rated value 690 V
surge voltage resistance rated value 6 kV
operating voltage
● at AC rated value 690 V
operating frequency rated value
● minimum 50 Hz
● maximum 60 Hz
Protection class
protection class IP IP65
degree of protection NEMA rating 1, 3R, 4X, 12
protection class IP on the front IP65
Dissipation
power loss [W] for rated value of the current at AC in hot 1.1 W
operating state per pole
Main circuit
operational current
● at AC-21 at 690 V rated value 25 A
● at AC-21 A at 240 V rated value 25 A
● at AC-21 A at 400 V rated value 25 A
● at AC-21 A at 440 V rated value 25 A
● at AC-23 A at 400 V rated value 20 A

3LD21031TL53 Subject to change without notice


11/16/2023
Page 1/6 © Copyright Siemens
operating power
● at AC-23 A at 240 V rated value 5 kW
● at AC-23 A at 400 V rated value 10 kW
● at AC-23 A at 440 V rated value 9.5 kW
● at AC-23 A at 690 V rated value 10 kW
● at AC-3 at 240 V rated value 4 kW
● at AC-3 at 400 V rated value 8 kW
● at AC-3 at 690 V rated value 7.5 kW
Auxiliary circuit
number of CO contacts for auxiliary contacts 0
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
operating voltage of auxiliary contacts at AC maximum 500 V
continuous current of the auxiliary contact rated value 10 A
insulation voltage of the auxiliary switch rated value 500 V
Suitability
suitability for use
● main switch Yes
● switch disconnector Yes
● EMERGENCY OFF switch Yes
● safety switch Yes
● maintenance/repair switch Yes
Product details
product feature can be locked into OFF position Yes
accessories
product extension optional
● motor drive No
● voltage trigger No
number of connectable NC contacts for auxiliary contacts 2
attachable maximum
number of connectable NO contacts for auxiliary contacts 2
attachable maximum
number of connectable CO contacts for auxiliary contacts 0
attachable maximum
number of bracket locks maximum 3
hasp thickness of the bracket locks 4 ... 8 mm
Short circuit
conditional short-circuit current with line-side fuse protection
● at 690 V by gG fuse rated value 50 kA
let-through current with closed switch
● at 240 V for combination switch + gG fuse maximum 3.5 kA
● at 440 V for combination switch + gG fuse maximum 3.5 kA
● at 690 V for combination switch + gG fuse maximum 4 kA
permissible
I2t value with closed switch
● at 240 V for combination switch + gG fuse maximum 4 kA2.s
● at 440 V for combination switch + gG fuse maximum 4 kA2.s
● at 690 V for combination switch + gG fuse maximum 4 kA2.s
design of the fuse link
● for short-circuit protection of the main circuit required fuse gL/gG: 25 A
● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A
operational current of upstream fuse rated value 25 A
according UL
operational current at AC according to UL 508/UL 60947-4-1 25 A
rated value
operating voltage at AC at 50/60 Hz according to UL 508/UL 600 V
60947-4-1 rated value
active power [hp] at AC at 480 V according to UL 508/UL 60947- 10
4-1 rated value
active power [hp] at AC at 600 V according to UL 508/UL 60947- 15
4-1 rated value
short-time withstand current (SCCR) at 600 V according to UL 5 kA
508/UL 60947-4-1

3LD21031TL53 Subject to change without notice


11/16/2023
Page 2/6 © Copyright Siemens
continuous current of upstream fuse according to UL rated value 50 A
type of fuse according to UL RK5
Connections
AWG number as coded connectable conductor cross section
solid
● maximum 8
● minimum 14
type of connectable conductor cross-sections for copper
conductor
● solid 1x (1,5...16mm²)
● finely stranded with core end processing 1x (1,5...10mm²)
● stranded 1x (1,5...16mm²)
type of connectable conductor cross-sections for auxiliary
contacts
● solid lateral auxiliary switch 2x (0,75 ... 2,5mm²), 1x 4mm²; front auxiliary switch 1x
(0,75 ... 2,5mm²)
● finely stranded with core end processing lateral auxiliary switch 2x (0,75 ... 1,5mm²), 1x 2,5mm²; front auxiliary switch 1x
2,5mm²
● stranded lateral auxiliary switch 2x (0,75 ... 2,5mm²), 1x 4mm²; front auxiliary switch 1x
(0,75 ... 2,5mm²)
type of electrical connection
● for main current circuit box terminal
● for auxiliary contacts connection terminals
Mechanical Design
height 84 mm
width 67 mm
depth 92.5 mm
type of device fixed mounting
fastening method Built-in unit fixed-mounted version
fastening method
● 4-hole front mounting Yes
● front mounting with central attachment No
● rail mounting No
net weight 247 g
Environmental conditions
ambient temperature during operation
● minimum -25 °C
● maximum 55 °C
ambient temperature during storage
● minimum -25 °C
● maximum 55 °C
Approvals Certificates
General Product Approval

Confirmation Miscellaneous

Declaration of Conformity Marine / Shipping other

Confirmation

other Environment

Miscellaneous Environmental Con-


firmations

3LD21031TL53 Subject to change without notice


11/16/2023
Page 3/6 © Copyright Siemens
Further information
Siemens has decided to exit the Russian market (see here).
https://press.siemens.com/global/en/pressrelease/siemens-wind-down-russian-business
Siemens is working on the renewal of the current EAC certificates.
Please contact your local Siemens office on the status of validity of the EAC certification if you intend to import or offer to supply these products to an
EAC relevant market (other than the sanctioned EAEU member states Russia or Belarus).
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3LD2103-1TL53
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3LD2103-1TL53
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3LD2103-1TL53
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

3LD21031TL53 Subject to change without notice


11/16/2023
Page 4/6 © Copyright Siemens
1 L1 3 L2 5 L3 N

-Q1

2 T1 4 T2 6 T3 N
-CI

1 2
L1 T1

3 4
L2 T2

5 6
L3 T3

N N

last modified: 6/20/2023

3LD21031TL53 Subject to change without notice


11/16/2023
Page 5/6 © Copyright Siemens
3LD21031TL53 Subject to change without notice
11/16/2023
Page 6/6 © Copyright Siemens