Verifone VX 520
Verifone VX 520
loading and configuration procedure for the different models of OMNI equipment
Verifone brand, also known as POS or Ticket Printer. OMNI vx610 Wireless
This equipment works wirelessly without any cables to receive data from the system.
works with a router or Access Point that emits a wireless signal that the vx610 device receives
and will be able to perform its function with the system. As a first step, we must introduce the
Load the equipment, so we must follow these steps: 1.- We need to identify the
file you need to upload, that is to introduce the software into the vx610 device
necessary for its activity. The file that is required will always be in a compact mode or
Zipped with the name SGvxp This file will always be found in the folder of the
Version of ControlGAS that is installed, it is also very important that the version of
The software load of the Omni VX610 must be in accordance with the ControlGas version.
installed. The procedure is indicated:
We need to edit the following file to configure the port to send the load to
Team 4.- Once we change the port number, we need to select the File option.
and save so that the change of the new COM number remains in the file, afterwards
We must execute it by double-clicking the file ddlvx610.bat and it will open the following window:
4 5.- Prior to this operation, the omni vx610 must already be in standby mode performing the
next steps: The F2 and F4 keys are pressed simultaneously, the keys are located
on the right side of the green display. It shows the legend that says: SYSTEM
MODE ENTRY PASSWORD, here we need to enter the following password; ATIOHS
(284647), is not going to write letters, only asterisks will be visible, we will hit Enter.
It is the green key located at the bottom. It will show us a menu that tells us;
CONTRAST F2, CLOCK F3, RESTART F4, and at the bottom of the green display where it
In this message, there are 4 purple keys from left to right on the second one, at the top.
On the display, there is an arrow pointing downwards; we press it, and other options are displayed.
We need to find or locate the option that says F2 DOWNLOAD, or in the letter F# that
It appears. It displays the following message; SYS MODE FILE FILE GROUP _1, and is pressed
the green Enter key is very IMPORTANT do not change the _1 since this group is the one that
use it to download the program. We type the same password ATIOHS(284647),
we select the F3 of FULL. The following message shows us other options, but we are going to
search with one of the purple keys from left to right for the COM1 option and press
F3. The following message displayed is; SYS MODE DOWNLOAD G 1, DOWNLOADING
NOW The team will start receiving the load and the previous window shows us the details
next:
5 The load has been completed, it is important to mention that for this load to be carried out
the serial cable RJ45 to DB9 (female) must be connected where indicated. To
to connect to the Print Server (SGPS), the following parameters must be programmed:
For this type of equipment, it needs to be configured and able to receive the signal directly from the
router or wireless Access Point, the commands are the following:
Press F2 and F4 simultaneously again with the purple key from left to right to
move the menu and select the EDIT option on F3 or F# with the number displayed to you;
Display the following message SYS MODE FILE FILE GROUP _1, it should not be moved.
group, press Enter We press Enter again until the arrows appear
displacement, press it until finding the option of: #HOSTIP: here the IP must be entered
assigned to the computer or server that has the Print Server (SGPS) active, for
To introduce it, press the F3 VALUE key; the yellow back key is used to delete. They are typed.
the numbers of the IP, for example: , to enter or mark the point, press the number 1 and
then the ALPHA key is pressed until the dot appears. The key is pressed
Enter The following command is #MYIP: an IP is assigned to it because it becomes a machine
further inside the network, it can be; it changes with F3 The next option is #DHCP in the
we will type in VALUE the number 0 because there is no server on our equipment
DHCP. The following command is #PORT: where the print server starts with the port
9711 to 9719, each OMNI vx610 is assigned one of them starting with 9711, which
we can change with F3 Value The following command is #MEDIA and must carry the value of
WIFI, it cannot be changed, it is fixed. The following command is #PROTOCOL and it must have the value of
TCP does not change, it is fixed. The next command is #SYSIP and it must have the value of
VERIFONE, this value must be created in the router or Access Point and in case that the
The router already has another piece of data, this data is entered in the Omni vx610. The following command is
WEP_KEYVAL: a password must be set that will be used by the router or Access Point
To access the wireless service, the password used is the following once
Once these configurations are made on the print server, the must be enabled.
port assigned in the omni and when starting the omni it will validate the version loaded in the omni and will enter
in communication with the Print Server (SGPS). As shown in the image
next:
NOTE: When the Verifone connects via the Ethernet cable or serial port,
you need to configure the default serial Com port that you get when connecting the Verifone to the PC;
a connection speed of 19200, the data bits must be set to 7, as well as the bits of
stop at 1, and regarding the parity it must be Even: OMNI 510 Serial and Ethernet
This model can work through a serial cable or Ethernet cable, that is to say it becomes
a point of a local network. In this model, there are two types of loads, one is SGvxp510, the
The load is in serial form, that is, a RJ45 to DB9 cable. The other is SGvxp510E, the load is
Ethernet form, that is, an RJ45 to RJ45 cable with a cable configuration
bn,n,bv,a,ba,v,bc,c (color code).
9 As in the previous model, we must make the corresponding load, identifying which
In both ways we are going to use it, it should be mentioned that some previous models of
510 does not have the 10 Base T connection, it can only be charged serially. 1.- MODE
SERIAL. The required file will always be in a compact or zipped format with the
name of SGvxp ETHERNET MODE. The file that is required just like the previous one is
Find in zip format with the name SGvxp510E.
10 The procedure is exactly the same as the previous model, you just need to select the
corresponding file, an image is attached for tracking: Subsequently, the editing is done.
file to send the load, it is reminded that it is similar to the previous equipment, it just needs to
please note that it is model 510.
11 The procedure for putting the equipment on standby to receive the load is the same as the example.
previous since the equipment is from the same brand. The following are the steps of
configuration of the model 510 and 510E SGvxp510: In this mode or type of load of the omni
you only need to connect the cable that comes from the CPU to the terminal as indicated in the
image, it will automatically validate the version that the team has, afterwards it will
indicate that it is loading data, starting with the sign +, the sign -, the sign # and
after several signs *. Subsequently, the display will say the message Press a key or
Swipe the card, the team is already working on issuing the ticket.
16 #TAG.- This variable indicates how the button will be identified: 0: Does not recognize the COM for the
Recognizes the COM for the button and requests to connect the button reader #FAMILY.
This variable indicates the button family: 1: Button from family 1. 6: Button from family 6. #BAR.-
Impresión del código de barras en el ticket: 0: No imprime el código de barras en el ticket. 1:
Print the barcode on the ticket. #DDV.- Print the monthly consumption for clients of
Credit or Print the monthly balance for debit clients 0 = Does not print consumption 1 =
Print the balance or the consumption for the month #CLX.- External client code The equipment
additional devices that can connect to the Verifone equipment must be placed in the Port of
Omni that is referred to as RS232, the devices that can be connected are the
next: Dot Matrix Printer with serial port, for immediate billing Reader of
Barcode Reader Ibutton In model 510 in Ethernet mode or with the load of
SGvxp510E, the link to the SGPS will be via the 10Base T port, two devices can be connected.
additional ones as mentioned in the previous point will be connected to the RS232 ports and
the excess, making the omni more versatile.
18 As in the previous model (vx610), we must do the loading in the same way, for
We need to identify the file that is needed to perform the download, that is to say, to introduce
the vx670 team the software necessary for its activity. The file that is required will be
always in a zipped or compact mode with the name SGvx670s. Once they have been
I made these configurations: HOSTIP, PORT, MYIP, GATEWAY, SUBNETMASK, MEDIA; in
The print server must enable the assigned port on the vx670 and restart it.
Omni will validate the version loaded on the Verifone and will communicate with the Server.
Printing (SGPS), is shown in the following image:
19 OMNI vx510r This model can work via serial cable or Ethernet cable, that is
it becomes a point in a local network. In this model, there is a type of load that is
SGvxp510R, As in the previous model, we must make the corresponding load,
identifying which type of connector we are going to use, it should be mentioned that some
Previous models of 510 do not have the 10 Base T connection, this Verifone model already has it.
with that option.
Before starting to load the software, we need to check if the program is loaded.
factory preset, since if this is the case, the memory of it will need to be cleared in order to
configure the parameters to be able to load our Verifone, for this you must connect to
the PC where this process will take place will use a RJ45 to DB9 cable. For this
Operation must follow the steps below: 1.- We must identify the file that
it is needed to perform the download, that is to say, to introduce the necessary software into the vx510r device
for your activity. The required file will always be in a compact or zipped mode with
the name of Clear Memory Omnis Once we open the file named Wipe.bat we
will be in charge of loading the necessary software to erase the memory of our Verifone to
reset, once we have our omni connected we will need to press Enter to start
the process.
22 OMNI vx570e This model can work via serial cable, Ethernet cable, and USB, it is
saying becomes a point of a local network. In this model there is a type of load that is
SGvx570e, Just like in the previous model 510R, we need to do the corresponding loading,
identifying which type of connector we are going to use, it should be mentioned that some
previous models do not have the 10 Base T connection, this Verifone model already has it.
that option, it is also worth mentioning that it already has an integrated USB port
provides additional flexibility, as it allows downloading applications from a drive
Flash memory in a simple and secure way.
23 Before starting to load the software, we must check if the program is loaded.
factory default, since if this is the case, the memory of this must be cleared in order to
configure the parameters to be able to load our Verifone, this is done within the
Verify manually, the steps to follow are as follows: 1.- When turning on the omni we
The following appears on the screen: Press the 1 key on our Verifone. VERIFONE s Vx570
Modem Profile Loader Conexant CX86501 (Eisenhower) Ver Profiles Loaded: 26 Press 1 to
Proceed: 2.- Next, the configuration of the country where you will work appears.
omni, which we are going to set as default region 14 MEX Modem Profile Select Total Files:
26 Country: 14 MEX SCROLL UP <F3> SCROLL DOWN <F4> ENTER to SELECT 3.- In the
On the next screen, press the key 5 to continue and confirm the change. Step 4.
we press the F2 and F4 keys at the same time 5.- It will ask us for the password of the verifone that
brings by default or from factory: After that we press the F3 key for the DOWNLOAD option
F3
24 7.- On the next screen, the GROUP ID appears. _1, for this option we press
Enter 8.- Again, we type the default password for the Verifone: We press F4 on the option
from MULTI-APP F Then we press F3 of FULL F Immediately a screen appears to us in the
which asks us if we want to clean the application that comes by default with the Verifone to which
we will give F3 of YES F3; and we confirm with the same option of YES F The next step is the
to load our Verifone with the ATIO software: To load the required software it must be
to connect to the PC where this process will take place, an RJ45 cable will be used to
DB9. For this operation, the following must be done; for the download, that is to say to introduce
the vx570e team the necessary software for its activity, the required file will be
always in a compact or zipped mode with the name SGvx570e.
26 VERIFONE VX520 In this version the terminal will connect via Ethernet, it becomes
at a point on a local network. There is a type of load that is SGvx520, for future version it
It will enable the RS232 communication not defined if it will be USB TYPE, it will be informed for the
connection of some accessory such as: barcode reader, IButton or Serial printer.
IMPORTANT NOTE: Unlike previous terminals, some options will be chosen
with the keyboard and not with the function buttons.
29 SOFTWARE LOAD Before starting to load the software, we must check if it has
loaded the factory default program, as if so it will need to be cleaned
memory of this to be able to configure the parameters to load our Verifone, this
It is done manually within the Verifone, the steps to follow are as follows: TERMINAL
NEW 1.- When we turn on the Vx, the following appears on the screen: Press the key 1 of the
terminal. VERIFONE s Vx520 Modem Profile Loader Conexant CX86501 (Eisenhower) Ver
Profiles Loaded: 26 Press 1 to Proceed: 2.- Next, the configuration appears for the
country where the Vx will work, which we will set as default region 14 MEX
Modem Profile Select Total Files: 26 Country: 14 MEX SCROLL UP <F3> SCROLL DOWN
Press ENTER to SELECT 3.- By performing this step, the device will restart and turn on again.
new, it will request the file upload 4.- The next step is to load our Verifone with
ATIO software: To load the required software, you must connect to the PC where
this process will be carried out, an RJ45 to DB9 cable will be used. For this operation it is necessary to
to carry out the following; for the download, that is to introduce the software into the vx520 device
necessary for your activity, the required file will always be in a compact mode with
the name of SGvx520.
30 The progress of the download is shown: Once these have been done
relevant configurations: HOSTIP, MYIP, SUBNETMASK, GATEWAY, PORT, in the
Verifone must configure the parameters set on the printing server.
You must enable the assigned port on the vx520 and upon restarting the VX520, it will validate the version.
loaded on the Verifone and will communicate with the Print Server (SGPS), as
it is shown in the following image
32 SOFTWARE LOAD VERIX Procedure on PC The .bat file is edited and executed
corresponding to the Verix model, in order to configure the assigned COM port The
file will depend on the Verix model: CLEANOMNI UTILITY Procedure on PC For
update a Verix or load a version onto a preloaded device, we will be able to use the
CleanOMNI utility, which frees us from any configuration on the device, NOT WITHOUT
BEFORE BACKING UP THE EQUIPMENT LICENSE. The loading method in Verix is
the same as the Preloaded Terminal, with the difference of the following files to load
on the PC: Inside the LimpiaVerifone folder, edit the Wipe.bat file. Write the port.
COM assigned in the device manager (In this case it's COM3) Save the
changes and run the same Wipe.bat file
34 TERMINAL Vx680 It is a terminal for operating on WiFi networks, in this version the
The terminal will connect securely using WEP. For connecting an accessory such as: reader
For barcode, IButton or Serial printer, it is necessary to have the respective cradle.
IMPORTANT NOTE: Unlike previous terminals, some options will be selected.
with the keyboard and the touch screen and not with the function buttons.