IC 912 LX
NTC-PTC/ P R V-I I-V/ Pt100 Tc
electronic controller with single intervention point
BUTTONS
Scrolls through the menu items Scrolls through the menu items fnc ESC function (quit) set Accesses the set point and Menus
Increases the values Decreases the values Parameter programmable Activates functions
Par. programmable Parameter programmable (see par. H33) Confirms the commands
(see par. H31) (see H32 parameter) Displays the alarms (if active)
Relay OUT Alarm Soft Start (and Set Point setting)
LED ON for relay on (energized);blinking for
delay, protection or enabling blocked.
ON for active alarm; blinking for silenced
alarm
ON for reduced Set Point;
blinking when Soft Start function is on;
PROGRAMMING MENU
The menu is divided into 2 levels; once users have pressed the Navigation at installer level(2):
‘set’ button for 5 seconds, they can access the user level folders (1) • By using the ‘UP’ / ‘DOWN’ buttons
Navigation at user level(1): you can scroll through all the folders in
• By using the ‘UP’ / ‘DOWN’ buttons the programming menu that only con-
you can scroll through all the folders in tain installer level parameters (2)
the programming menu that only contain
user level parameters (1) How to modify the parameter value (on both levels):
• When the ‘set’ button is pressed, the
How to access the installer level (2): set first folder in the menu is displayed.
• By using the ‘UP’ / ‘DOWN’ buttons, scroll (e.g.: “rE1” folder)
through the user level folders (1) until the
folder with the “CnF” label is displayed. • By using the ‘UP’ / ‘DOWN’ buttons
Then press ‘set’ to access the parameters you can scroll through all the folders in
contained in it. current level.
• By pressing the ‘set’ button next to
• By using the ‘UP’ / ‘DOWN’ all the para- the selected folder (in this case “SFt”)
set the first parameter in the current level
meters in the user level (1) in ‘CnF’ are dis-
played, continue until the ‘PA2’ label is not will be displayed. Select the desired
longer displayed and press ‘set’. parameter using the ‘UP’ / ‘DOWN’ keys.
• By pressing the ‘set’ button next to ‘PA2’ • By pressing the ‘set’ button the value
set the first folder containing installer level of the selected parameter is displayed
set and by using the ‘UP’ and ‘DOWN’ but-
parameters will be displayed and then the
tons it can be modified.
‘rE1’ folder.
PASSWORD
Access to parameter handling both at user level and installer level • If password 1 is enabled (not 0) you will
can be limited by using passwords. The passwords can be enabled set be asked to enter it. Perform the operation
by setting the PA1 (user password) and PA2 (installer password) by selecting the correct value using the
‘UP’ and ‘DOWN’ keys and press the ‘set’
in the ‘dIS’ folder. The passwords are enabled if the value of the
button to confirm.
2 parameters PA1 and PA2 is not 0.
• To access the “Programming” menu hold
down the “set” button for more than 5
Installer level (2) parameters
seconds. In the programming menu scroll through the folders containing
set If specified, the user level(1) access PASS- the user level parameters using the UP’ and ‘DOWN’ buttons until
WORD will be requested the CnF folder is displayed.
• Press the ‘set’ button to enter the ‘CnF’ • Use the ‘UP’ / ‘DOWN’ buttons to
folder where the ‘PA2’ label is present. select the correct value of the
installer password and then press the
‘set’ button to access the installer
• Scroll through the folder parameters level parameters (2).
and press the ‘set’ button next to the
‘PA2’ label, ‘0’ will appear on the dis- If the password is not entered correctly, the device will display
play. the ‘PA2’ label again and the operation will have to be repeated.
At each level in both menus, when the “fnc” button is pressed or the 15 second time out elapses, you are taken back to the higher
display level and the last value on the display is stored.
COPY CARD
The Copy Card is an accessory connected to the TTL serial port Download from reset
used for quick programming of the unit parameters (upload Connect the copy card when the instrument is OFF. The program-
and download parameter map to one or more units of the same ming parameters are downloaded when the device is switched
type). Upload (UL label), download (dL label) and copy card on. At the end of the lamp test, the following messages are dis-
formatting (Fr label) operations are performed in the following played for about 5 seconds:
way: • dLY label if copy operation is successful
• The ‘FPr’ folder contains the com- • DLn label if operation fails
set mands necessary for use of the Copy
Card. Press ‘set’ to access the func-
tions. DOWNLOAD
ALARMS
IC 912 LX MODELS
LABEL ALARM CAUSE EFFECTS* Resolving problems NTC/PTC V-I Pt100-Tc
E1 Probe 1(control) • measuring of values outside the “E1” label appears on display; • check the probe wiring
faulty nominal reading range Controller enabled as indicated by • replace the probe
• control probe faulty/shorted/open the On1 and OF1 parameters if pro-
probe grammed for the Duty Cycle
AH1 High temperature • value read by probe 1 > HA1 Alarms created in the “AL” folder • Wait for temperature
alarm after time equal to “tAO”. with the AH1 label value read by probe 1 to
(see “ MIN MAX ALARMS” and fall below HA1
description of “HA1”, “Att” and
“tAO” parameters)
AL1 Low temperature • value read by probe 1 < LA1 Alarms created in the “AL” folder • Wait for temperature
alarm after time equal to “tAO”. with the AL1 label value read by probe 1 to
(see “ MIN MAX ALARMS” and go above LA1
description of “LA1”, “Att” and
“tAO” parameters)
EA External alarm • control of alarm from active D.I. if Alarms signalled in the “AL” folder • Manual silencing
“H11” = 8 or 9 with the EA label It only blocks the by pressing button
(see description of “H11” parameter) controllers if “H11”=9
* Effects common to all alarms: Alarm LED permanently on; Buzzer activated (if present););
MAX-MIN Temperature expressed as an absolute value (par “Att”=0) Abs(olute) Temperature in relation to set point (par “Att”=1) rEL(ative)
ALARMS 2
1 Off
AFd AFd
AFd AFd
set
LA1/HA2 HA1/HA2
SP1+ LA1/SP2 + LA2 SP1+ HA1/SP2 + HA2
Minimum temperature alarm Temperature lower than or equal to LA1 (LA1 with sign) Temperature lower than or equal to set point +LA1 (LA1 positive only)
Maximum temperature alarm Temperature higher than or equal to HA1 (HA1 with sign) Temperature lower than or equal to set point +HA1 (HA1 positive only)
Minimum temperature alarm Temperature higher than or equal to LA1+AFd Temperature higher than or equal to set point + LA1 + AFd
back swing set point -|LA1|+AFd
Maximum temperature alarm Temperature lower than or equal to HA1-AFd Temperature lower than or equal to set point+HA1-AFd
back swing
if Att=reL(ative) LA1 must be negative: therefore set
point+LA1<set point because set point+(-|LA1|)=set-|LA1|
IC 912 LX 2/6
PARAMETER TABLE
PAR. RANGE DEFAULT LEVEL M.U. PAR. RANGE DEFAULT LEVEL M.U.
SP1 LS1...HS1 0.0 °C/°F H00 IC 912 LX NTC/PTC PtC/ntC PtC/ntC* 1 flag
(!)
Unt rEL / / 1 /
0/1/2 0 2 hours/mm/sec
tAb / / 1 /
SEn 0/1/2/3 0 2 num
Sdi PA2 label
0...30.0 0 2 °C/°F
In the CnF folder you can access all level 2 parameters with the PA2 label by
Att AbS/rEL AbS 2 flag pressing the “set” button
Add label Alarms-AL label
UL / / 1 /
label FPr
PA1 0...250 0 1 num (3) If the Fr command is used, the data entered in the card will be perma-
PA2 ** 0...250 0 2 num nently lost. This operation cannot be undone. After the operation with the
Copy Card, the controller must be switched off and then switched back on
ndt IC 912 LX NTC/PTC n/y n 1 flag
IC 912 LX V-I n/y/int
IC 912 LX Pt100-Tc n/y WARNING (!)
If one or more parameters marked with (!) are modified, the controller
CA1 -30.0...30.0 0 1 °C/°F
must be switched off after the modification and then switched back on
CAI 0/1/2 2 2 num
LdL IC 912 LX NTC/PTC -67.0...HdL -50 2 °C/°F PLEASE NOTE:
IC 912 LX V-I -99...HdL * The parameters dro, H11, H13 and H14 are only present in IC 915 LX
IC 912 LX Pt100-Tc -328...HdL * NTC/PTC and Pt100/TcJ-TcK models.
HdL IC 912 LX NTC/PTC LdL...302 140 2 °C/°F Parameters H03 and H04 are only present in the IC 915 LX V-I model
IC 912 LX V-I LdL...100 * * The default value depends on the model
IC 912 LX Pt100 LdL...1999 * ** Visible at level 1 in the CnF folder and can be set at level 2 in the diS
dro IC 912 LX NTC/PTC °C/°F °C 1 flag folder
IC 912 LX Pt100
DESCRIPTION OF PARAMETERS
CONTROLLER 1 (folder with “rE1” label) dn1 Start-up delay. The specified time must elapse between the controller
HC1 If set to H, the controller operates in heating mode. If set to C, the con- relay start-up request and actual start-up.
troller operates in cooling mode. do1 Delay after shut-down. The specified time must elapse between shut-
OS1 Offset Setpoint down of the controller 1 relay and a subsequent start-up
db1 Operating band 1 See ON-OFF control diagram di1 Delay between start-ups. The specified time must elapse between two
dF12 Relay OUT1 intervention differential. The load will stop when Set point is subsequent start-ups of controller
reached (as indicated by the control probe) and will restart at a temper- dE1 Shut-down delay. The specified time must elapse between shut-down of
ature equal to setpoint plus (or minus, depending on HC1 the value of the controller 1 relay and a subsequent start-up
the differential. See ON-OFF adjustment diagram NOTE: for parameters dn1, do1, di1, dE1 0= not active
HS1 Maximum value for set point On1 Controller start-up time if probe is faulty. If set to “1” with Of1 at “0”
LS1 Minimum value for set point the controller is always on whereas if Of1 >0 it operates in duty cycle
HA1 Maximum alarm OUT1 See Max/Min. Alarm diagram mode.
LA1 Minimum alarm OUT1 See Max/Min. Alarm diagram. OF1 Controller shut-down time if probe is faulty. If set to “1” with On1 at “0” the
controller is always on whereas if On1>0 it operates in duty cycle mode.
IC 912 LX 3/6
SOFT START (folder with “SFt” label) CAI Offset intervenes on display, thermostat control or both.
0 = only modifies the temperature displayed
N.B.: The SOFT START function is button, D.I. or function selectable. 1 = adds to the temperature used by controllers not the temperature
The Soft Start controller can be used to set the temperature gradient displayed that remains unchanged;
required to reach a specific set point in a specific period of time. This 2 = adds to temperature displayed that is also used by the controllers
function automatically gives you a progressive increase of the control LdL Minimum value the instrument is able to display.
HdL Maximum value the instrument is able to display.
set point from the Ta value (ambient temperature at start-up) to the
dro Select °C or °F to display temperature read by probe.
value actually displayed. This means that a rise in temperature can be N. B.: switching from °C to °F or vice versa DOES NOT modify set
immediately stopped and the risk of overshooting reduced. points, differentials, etc. (e.g. set point=10°C becomes 10°F)
dSi Value (in degrees) of each of subsequent increases (dynamic) of adjust- CONFIGURATION (folder with “CnF” label)
ment point 0=disables the SOFT START function. H00 Selection of probe type.
dSt Time between two subsequent increases (dynamic) of set point H01 Output link. 0 = independent; 1 = dependent; 2 = Neutral Area (or win-
Unt Unit of measurement (hours, minutes, seconds) dow)
SEn Enabled outputs. Establishes which outputs the function must be enabled H02 Button activation time if buttons are configured for a second function.
on: 0 = disabled; 1 = OUT 1; 2 = 3 = not used; For the ESC, Up and DOWN buttons configured for a second function
Sdi Function reinsertion threshold. Establishes the threshold beyond which (defrost, aux, etc) the time for quick enabling is set. Fa Aux is an excep-
the SOFT START function is automatically re-inserted tion and has a set time of 1 second
H03 Minimum value of current input
H04 Maximum value of current input
ALARMS (folder with “AL” label) H05 Window filter. -2=very fast; -1=fast; 0=normal; 1=slow; 2=very slow
Att Parameter “HA1” and “LA1” modes, as absolute temperature values or as H06 button/aux input/door switch light active when instrument is off (but
differential compared with the Set point. powered)
0 = absolute value; 1 = relative value. H08 Stand-by operating mode. 0= only display is switched off; 1= display on
AFd Alarm differential. and controllers disabled; 2= display off and controllers disabled;
PAO Alarm exclusion time on device start-up after a power failure. H10 Output delay from power-on Attention! If = 0 is not active; if ≠ 0 the
SAO Alarm exclusion time after reaching the Set point. 0 = disabled. If >0, an output will not be activated before this time has expired
alarm will be generated if the Set point is not reached after the time (in H11 Configuration of digital inputs
hours) set by this parameter. 0 = disabled; 1 = SOFT START; 2 = Set point Offset;
tAO Temperature alarm signal delay time. 3 = outputs shut down; 4 = periodic cycle; 5 = auxiliary output;
6 = stand-by 7 = maintenance request
COMMUNICATION (folder with “Add” label) 8 = external alarm 9 = external alarm disables controllers.
dEA Device address: indicates the device address to the management protocol. H13 Polarity and priority Digital Input
FAA Family address: indicates the device family to the management protocol. no= normally open/ nc= normally closed /
noP= normally open with polarity / ncP= normally closed with polarity
DISPLAY (folder with “diS” label) see “H13 parameter configuration” table
H14 Digital input enabling delay
Keyboard Lock
H31 UP button configurability.
Keyboard operating can be locked by programming the “Loc” para- 0 = disabled; 1 = SOFT START;
meter (see folder with “diS” table). If the keyboard is locked you can 2 = Set point Offset; 3 = outputs shut down;
access the Programming Menu by pressing the “set” button. The Set 4 = periodic cycle; 5 = auxiliary output (aux);
point can also be displayed. 6 = stand-by; 7 = maintenance request
H32 DOWN button configurability. Same as H31.
LOC Keyboard locked (set point and buttons). However, you can still access the H33 fnc button configurability. Same as H31.
parameter programming menu and modify the parameters including the rEL Device version. Read only parameter.
status of this parameter to allow keyboard unlocking. y = yes; n = no. tAb Reserved. Read only parameter.
PA1 Password 1. When enabled (value is not 0) it represents the access key COPY CARD (folder with “Fpr” label)
to level 1 parameters. UL UpLoad: transfer of programming parameters from instrument to Copy
PA2 Password 2. When enabled (value is not 0) it represents the access key Card.
to level 2 parameters. dL downLoad: transfer of programming parameters from Copy Card to
ndt number display type. Display with decimal point. device.
y = yes, range = -99...10 Fr Format. Cancelling all data entered in the copy card.
n = no, range = -99,9 ... 100,0 N.B.: if the “Fr” parameter is used (copy card formatting) the data
int = integer, range = -990...1000 entered in the card will be permanently lost. This operation can-
CA1 Calibration 1. Positive or negative temperature value that is added to the not be undone. After the operation with the Copy Card the con-
value read by control probe (probe 1) before being displayed or used troller must be switched off and then on again
for control.
HC1=H HC1=C
IC 912 LX 4/6
TECHNICAL DATA IC 912 LX NTC/PTC IC 912 LX P/R/V-I/I-V IC 912 LX Pt100/TC
Front protection IP65 IP65 IP65
Casing PC+ABS plastic resin body PC+ABS UL94 V-0, PC+ABS plastic resin body PC+ABS UL94 V-0, PC+ABS plastic resin body PC+ABS UL94 V-0,
polycarbonate front, thermoplastic resin buttons polycarbonate front, thermoplastic resin buttons polycarbonate front, thermoplastic resin buttons
Dimensions front keypad 74x32 mm, depth 59mm (excluding terminals) front keypad 74x32 mm, depth 59mm (excluding terminals) front keypad 74x32 mm, depth 59mm (excluding terminals)
Assembly each panel with drilling template 71x29mm (+0.2/-0.1mm) each panel with drilling template 71x29mm (+0.2/-0.1mm) each panel with drilling template 71x29mm (+0.2/-0.1mm)
Operating temperature -5°C...55°C -5°C...55°C -5°C...55°C
Storage temperature -30°C...85°C -30°C...85°C -30°C...85°C
Ambient operating and storage 10...90% RH (non-condensing) 10...90% RH (non-condensing) 10...90% RH (non-condensing)
humidity
Display range NTC: -50...110°C (-58...230°F) / PTC: -50...140°C(-58...302°F) -99...100 (ndt=n), -99,9...100,0 (ndt=y), -999...1000 (ndt=int) Pt100: -150...650°C / TcJ: -40...750°C / TcK: -40...1350°C*
on display 3 1/2 digits plus sign on display 3 1/2 digits plus sign on display 3 1/2 digits plus sign
Digital Input 1 voltage-free parameter-configurable digital input 1 voltage-free parameter-configurable digital input 1 voltage-free parameter-configurable digital input
Analogue input 1 NTC or 1 PTC (parameter selectable) 1 V-I (0-1V, 0-5V, 0-10V, 0-20...mA, 4...20mA par.H00) Pt100 or 1 TcJ or TcK (depending on model)
Serial TTL for connection to Copy Card or TelevisSystem TTL for connection to Copy Card and Televis System TTL for connection to Copy Card or TelevisSystem
Digital outputs (configurable) 1 SPDT 8(3)A 1/2 hp 250 Va 1 SPDT 8(3)A 1/2 hp 250 Va 1 SPST 8(3)A 1/2 hp 250 Va
Buzzer output only in specific models from only in specific models from only in specific models from
Measurement range from -50 to 140°C from -999 to 1000 from -150 to 1350
Accuracy better than 0.5% of full scale value + 1 digit better than 0.5% of full scale value + 1 digit see “Pt100/TcJ/TcK models” table
Resolution 0,1°C (0,1°F up to +199,9°F; 1°F over) 1 or 0.1 digits depending on parameter settings see “Pt100/TcJ/TcK models” table
Power consumption 1,5 W max(mod. 12V) / 3 VA max (mod. 230V) 1,5 W max(mod. 12V) / 3 VA max (mod. 230V) 1,5 W max(mod. 12V) / 3 VA max (mod. 230V)
Power supply 12Va/c, 12/24 Va/c, 24Va/c 10%, 12Va/c, 12/24 Va/c, 24Va/c 10%, 12Va/c, 12/24 Va/c, 24Va/c 10%,
110/115Va, 220/230 Va 10% 50/60 Hz 110/115Va, 220/230 Va 10% 50/60 Hz 110/115Va, 220/230 Va 10% 50/60 Hz
IC 912 LX 5/6
EWPA-EWHS PROBES CONFIGURATION
EWHS 280 2 wires EWHS 310 4 wires
brown
Probe
8 9 10 11 8 9 10 11
blue GND
8 9 10 11 RH T
GND
Transducer
brown
DISCLAIMER
TELEVIS SYSTEM
This document is exclusive property of Eliwell and cannot be reproduced
and circulated unless expressly authorized by Eliwell. Although Eliwell has
taken all possible measures to guarantee the accuracy of this document, it
declines any responsibility for any damage arising out of its use. The same
applies to any person or company involved in preparing and writing this Personal Computer
document. Eliwell reserves the right to make any changes or improve- TTL + PCI1110/1120
ments without prior notice and at any time.
-
The technical characteristics in this document concerning measure-
ments (range, accuracy, resolution, etc.) refer to the instrument in TelevisCompact
the strictest sense and not to any accessories provided such as BusAdapter -
probes, for example. This means, for example, that an error intro-
duced by the probe is added to any error that is typical of the TelevisStation
instrument.
The Televis remote control systems can be connected using the
TTL serial port (the 130 or 150 485 BUS ADAPTER TTL-RS interface
module must be used). To configure the instrument to do this, you
need to access the “Add” folder and use the “dEA” and “FAA” RS485
parameters.
CONDITIONS OF USE
PERMITTED USE
For safety reasons the instrument must be installed and used in accordance with the instructions supplied.
Eliwell & Controlli s.r.l. Users must not be able to access parts with dangerous voltage levels under normal operating conditions. The
Via dell'Industria, 15 Zona Industriale Paludi device must be suitably protected from water and dust according to the specific application and only be
32010 Pieve d'Alpago (BL) ITALY accessible using special tools (except for the front keypad). The device can be fitted to equipment for house-
Telephone +39 0437 986111 hold use and/or similar use in the refrigeration sector and has been tested with regard to safety in accordance
with the European harmonized reference standards: It is classified as follows:
Facsimile +39 0437 989066
• as an automatic electronic control device to be integrated as regards its construction;
Internet http://www.eliwell.it
• as a 1 B type operated control device as regards its automatic operating features;
• as a Class A device in relation to the category and structure of the software.
Technical Customer Support: UNPERMITTED USE
Telephone +39 0437 986300 The use of the unit for applications other than those described above is forbidden. It should be noted that the
Email: [email protected] relay contacts supplied with the device are functional and therefore exposed to potential faults. Any protec-
tion devices required to comply with product requirements or dictated by common sense due to obvious safe-
Invensys Controls Europe ty reasons should be installed externally.
An Invensys Company
cod.9IS44019
10-05 GB
IC 912 LX 6/6