0% found this document useful (0 votes)
6 views2 pages

PD Midea Brochure Rooftop Basefit 460V 20230104 V1

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views2 pages

PD Midea Brochure Rooftop Basefit 460V 20230104 V1

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Cooling with optional electric heat and gas/electric models— roof curb (in inches)

Packaged Rooftop
15 1/2”

54 9/16” 32 1/4” 3.000 84 13/16”


19 3/8”
3.000 SUPPLY

15 13/16”

37 15/16”
RETURN
45 1/8”

-BaseFit Series
14.000
3 9/16”
Cooling and Gas/Electric
7.5 to 12.5 Tons, 460V, 60 Hz
1 3/4”

54 9/16”
84 13/16”

Cooling with optional electrical heat and gas/electric units—front and side views (in inches)

2-3/4”
Ø2
Ø1-3/8”

2-3/4”
Ø2
48-5/16”
48-3/4”

Ø1-3/8”

44-3/16”
30-3/16”
6-5/16”

Ø7/8”
14-7/16”

2-5/16”
7-3/4” 23-3/4” 7-3/4”

7-3/4” 23-3/4” 7-3/4” 9-7/8”


37-15/16”
(GBC UNIT ONLY) 58-7/8”
88-7/16”

Midea Building Technologies Division


Midea Group
Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China

Postal code: 528311

mbt.midea.com www.midea-group.com

Midea reserves the right to change the specifications of the product, and to withdraw or

replace products without prior notification or public announcement. Midea is constantly

developing and improving its products.


Features Generaldata— 7.5–12.5tons—460volts

7.5Ton 8.5Ton 10Ton 12.5Ton

Cooling system can realize Indoor & outdoor top cover plate can realize MRB-75CWN1Z-C MRB-85CWN1Z-C MRB-100CWN1Z-C MRB-125CWN1Z-C
1 100%/75%/50%/25% four speed 6 individual remove, and fixed indoor side is MRB-75HG125WN1Z-C MRB-85HG125WN1Z-C MRB-100HG180WN1Z-C MRB-125HG180WN1Z-C
Model name MRB-75HG180WN1Z-C MRB-85HG180WN1Z-C MRB-100HG225WN1Z-C MRB-125HG225WN1Z-C
adjustment, saving energy. more convenient for maintenance.
MRB-75HG225WN1Z-C MRB-85HG225WN1Z-C MRB-100HG250WN1Z-C MRB-125HG250WN1Z-C

Power supply (V/Ph/Hz) 460/3/60 460/3/60 460/3/60 460/3/60


Adopt all DC outdoor fan motor design, can
Bottom plate easy to remove, more Gross Cooling Capacity 90000 102000 120000 150000
realize 10 speed adjustment, improve
2 7 convenient, no need to do lifting.
system reliability, especially in the low EER(Downflow/Horizontal) 11.2 11.2 11.2 11.0
ambient.
Nominal Airflow CFM / AHRI Rated CFM 3200/3000 3700/3000 3700/3200 4600/4000
Cooling
Perfor AHRI Net Cooling Capacity 86000 104000 140100 140000
(a)
mance
Ambient temp range 40~125°F super low Integrated Energy Efficiency Ratio (IEER) 14.8 14.8 14.8 14.2
Bottom air discharge convert to side
3 cooling(ambient temp 0°F) can be 8 discharge more flexible, no need forklift. Percent Capacity @ partload (Stage1/Stage2) 58/100 47/100 44/100 32/100
customized
System Power (kW) 7.68 9.29 10.18 12.73

Type Scrolls Scrolls Scrolls Scrolls


Compressor
Number 2 2 2 2
Gas pipe maintenance is more flexible, can
4 Meet AHRI &ETL certification, meet UL 60335. 9 directly move out follow the guide rail. Sound Outdoor Sound Rating( BELS) 8.2 8.2 8.2 9.2

Outdoor Coil Type Microchannel Microchannel Microchannel Microchannel

Type Microchannel Microchannel Microchannel Microchannel

Indoor Coil Tube Size (in.) ID 0.98 0.98 1.57 1.57


Can directly replace competitor’s same type All series adopt 4pcs 20*20*2 filter, more
5 10 convenience.
rooftop package unit. CFM EXV EXV EXV EXV

Refrigerant Control Propeller Propeller Propeller Propeller

Type Direct/10 Direct/10 Direct/10 Direct/10


Outdoor Fan
Drive Type/No.Speeds 8400 8300 8300 10000

Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal


R410A Indoor Fan Drive Type/No.Speeds Belt/ 1 Belt/ 1 Belt/ 1 Belt/ 1

Number Motors 1 1 1 1

Type Furnished Throwaway Throwaway Throwaway Throwaway


Cooling with optional electrical heat and gas/electric units—overview Filters
Number Size Recommended (4)20*20*2 (4)20*20*2 (4)20*20*2 (4)20*20*2

Circuit A (lbs) 3.97 4.85 5.29 7.72


Refrigerant
Charge Circuit B (lbs) 3.31 4.41 4.85 5.95

Net Weight(lbs) 906/ 981/ 1003/ 1014 929/ 1004/ 1026/ 1037 952/ 1052/ 1063/ 1063 1060/ 1160/ 1171/ 1171

Gross Weight(lbs) 981/ 1056/ 1078/ 1089 1004/ 1079/ 1101/ 1112 1027/ 1127/ 1138/ 1138 1135/ 1235/ 1246/ 1246

Net Dimensions W×H×D (in.) 88 1/4''*49 1/16''*59 1/2'' 88 1/4''*49 1/16''*59 1/2'' 88 1/4''*49 1/16''*59 1/2'' 88 1/4''*49 1/16''*59 1/2''
Packed Dimensions W×H×D (in.) 89 1/2''*49 5/8''*59 13/16'' 89 1/2''*49 5/8''*59 13/16'' 89 1/2''*49 5/8''*59 13/16'' 89 1/2''*49 5/8''*59 13/16''

(a) Units are AHRI Certified to AHRI Standard 340-360(I-P). Rating conditions are 95°F outdoor air temperature,80°F entering dry bulb, 67°F entering wet bulb with minimum
external static pressure as determined by rating standard.
(b) Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions.

CONDENSATE
GAS CONNECTION DRAIN
INSIDE CONNECTION

You might also like