Convivio 3-Phase Distribution Boards: From 12 To 54 Poles (Outgoing Terminals)

The document details ConvivioTM 3-phase distribution boards available in configurations from 12 to 54 poles, designed for DIN-rail mounting circuit breakers. These boards comply with IEC 61439-3 standards, feature a maximum voltage of 480 V, and are equipped with various accessories for installation. It lists specific models, their ratings, and technical characteristics, including short-time and peak withstand currents.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views1 page

Convivio 3-Phase Distribution Boards: From 12 To 54 Poles (Outgoing Terminals)

The document details ConvivioTM 3-phase distribution boards available in configurations from 12 to 54 poles, designed for DIN-rail mounting circuit breakers. These boards comply with IEC 61439-3 standards, feature a maximum voltage of 480 V, and are equipped with various accessories for installation. It lists specific models, their ratings, and technical characteristics, including short-time and peak withstand currents.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ConvivioTM 3-phase distribution boards

from 12 to 54 poles (outgoing terminals)

6 044 00 6 044 02 6 044 42

Technical characteristics p. 209

3-phase distribution boards for DIN-rail mounting circuit breakers


IP 40 - IK 08 with door
Conform to standard IEC 61439-3: busbar type tested (Lovag certified)
Maximum voltage 480 V± ; Rated short-time withstand current (Icw): 17 kA 0.2 s
Rated peak withstand current (Ipk): 34 kA
Ambient temperature: 50 °C continuously
White RAL 9003
Supplied with: surface or flush-mounting box, door with handle, faceplate, fully isolated tin plated copper busbar
The number of holes of earth and neutral terminal blocks are equal to the number of outgoing devices
Pack Cat.Nos Distribution boards up to 125 A Pack Cat.Nos Accessories
Maximum rating 125 A Fixing supports for terminal blocks
Flush or surface mounting 10 6 054 93 Kit consisting of 2 insulated fixing supports for
Equipped with 4 rail for main circuit breaker : terminal blocks for earth
3P or 3P + N (Neutral on the right-hand side),
1 module/pole, 4 rail mounting MCB Insulating caps
No of poles No of 3P
10 6 054 94 Set of 20 insulating caps for protecting unused
(outgoing terminals) ways outgoing terminals of the busbar
1 6 044 00 12 4 Blanking plate RAL 7035
1 6 044 01 18 6
1 6 044 02 24 8 Separable into modules or 1/2 modules
1 6 044 03 30 10 10 0 016 65 18 modules
1 6 044 04 36 12
1 6 044 05 42 14
1 6 044 06 48 16
1 6 044 07 54 18
Distribution boards up to 250 A
Maximum rating 125 A
Flush or surface mounting
Equipped with mounting plate for main circuit
breaker: DRX 125 MCCB
No of poles
(outgoing terminals) No of 3P ways
1 6 044 30 12 4
1 6 044 31 18 6
1 6 044 32 24 8
1 6 044 33 30 10
1 6 044 34 36 12
1 6 044 35 42 14
1 6 044 36 48 16
1 6 044 37 54 18
Maximum rating 250 A
Flush or surface mounting
Equipped with mounting plate for main circuit
breaker: DRX 250 MCCB
1 6 044 40 18 6
1 6 044 41 24 8
1 6 044 42 30 10
1 6 044 43 36 12
1 6 044 44 42 14
1 6 044 45 48 16
1 6 044 46 54 18

208