0% found this document useful (0 votes)
4 views1 page

Gad Stas Fis L01 Z03 DWG 001012 PDF 05 D

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views1 page

Gad Stas Fis L01 Z03 DWG 001012 PDF 05 D

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

KEY PLAN

X450 X460 X470 X480 X490 X500 X510 X520 X530


X200 X210 X220 X230 X240 X250 X260 X270 X280 X290 X300 X310 X320 X330 X340 X350 X360 X370 X380 X390 X400 X410 X420 X430 X440 X450 X460 X470 X480 X490 X500 X510 X520 X530 X540 X550 X560 X570 X580 X590 X600 X610 X620 X630 X640 X650 X660 X670 X680 X690 X700

10000 10000 10000 10000 10000 10000 10000 10000


Y800 Y800

Y790 Y790

Y780 Y780
B03

TA E ES IS 08 OF 08
Y770 Y770

2
Y760 Y760

S- FE DA DE

I
/D0
Y750 Y750

DM
FI R
S- D SY TEC L 01-

02
Y740 Y740

F0 01-S RA-S

5/L
L0 WG ST T

CM
Y730 Y730

1- I F 5 A F Y720 Y720

Z0 NO EM ON

F0
IT CLOSET F 05 /L0 -SF D-
B02
V1 4

DM
Y710 B02 Y710

F0 05/L/L02/2/M1 D-2421
06 OF 06 B03
/C0 3- 1.810
Y700 05 OF 06 07 OF 08 Y700

DW :

CM
4/S0 5/L 02 M1 1 FOR CONTINUATION REFER DWG NO: Y690 Y690

2 G- 02 /M1 2 GAD-STAS-FIS-L01-Z03-DWG-001014
Y680 Y680

00 /M 3 Y670 Y670

14 Y660 Y660
S 20

FOR CONTINUATION REFER DWG NO:


Y650 B02 B02 Y650

12 B03

GAD-STAS-FIS-L01-Z02-DWG-001006
FW Y640
03 OF 06 04 OF 06 Y640
06 OF 08

S
Y630 Y630

V14
Y620

5
Y620

S0
Y610
/C 0
Y610

C
4/
4/S Y600
B02 B02 B03 B03
Y600

C0
03 Y590
01 OF 06 02 OF 06 04 OF 08 05 OF 08
Y590

3/
VOID
Y580
Y580 Y580

V1
Y570 Y570

SPACE Y560

Y550
Y560

Y550

Y540 B01 B01 B03 B03 Y540

F0
Y530 03 OF 04 04 OF 04 02 OF 08 03 OF 08 Y530

5 /L0
Y520 Y520

2/M
F Y510 Y510

F OR Y500 Y500

47
F0 05/L VES EL

S
Y490 Y490

F 5 0 EC
F0 05/L/L02/2/M0DA
Y480 Y480

TR B01 B01 B03


IC Y470 Y470
01 OF 04 02 OF 04

C
01 OF 08
5/L 02 M0 7
1.8 AL C
AV

DM
Y460 Y460

02 /M0 8 09 LO
Y450 Y450

/M 9

DM
C 10 S ET
Y440

Y430
Y440

Y430

STAIR B05 B04

DM
Y420 Y420

AT TH Y410
03 OF 03 01 OF 01
Y410

DM
IS GALLERY 109 Y400 Y400

01
GA R Y390 Y390

BY OO

/D
D- 1.090 Y380 Y380

02
B05

C
L0 ST R VE M I Y370 Y370

5/L
02 OF 03
1 AS E F SD S D
Y360 Y360
CM
F -SA

F0

S
Y350

-F ER A S ET
Y350

F0 05/L -SFD DM IS
Y340 Y340

5/L 02 -2 -L DW YS ECT
Y330
Y330
B05

/M 5 2
02 /M0 3

02 /M0 D-2
/M 3
CM 01 G TE IO Y320 01 OF 03 Y320

-Z

10000
03 NO M
Y310 Y310
DM N

5/L 02 F
04

F0 05/L-RA-S

06
Y300 Y300

-D : Y290 Y290

W ELECTRICAL CLOSET S C

F 01
X200 X210 X220 X230 X240 X250 X260 X270 X280 X290 X300 X310 X320 X330 X340 X350 X360 X370 X380 X390 X400 X410 X420 X430 X440 X450 X460 X470 X480 X490 X500 X510 X520 X530 X540 X550 X560 X570 X580 X590 X600 X610 X620 X630 X640 X650 X660 X670 X680 X690 X700

G-

L
00
20
14 F05
/L0
1/D
17A
FW V13/C
05 /S02
S GENERAL NOTES:
F05
/L0 ˃ Smoke detector coverage area following 9 Meter and Detectors within a distance equal to or less than 0.7 times
1/D F05
15
30 17 /L01 the nominal 9m spacing.
FW
/D1 ˃ Heat detector coverage area following 7 Meter and Detectors within a distance equal to or less than 0.7 times the
V14/C 8
S

20
0 4/S01 nominal 7m spacing.

06

17
V13/C06/S02

4/S
>3rd fixes shall be as per approved Architectural layout wherever applicable.

0
>Cable trays/trunks shall be as per containment layout please refer below client reference drawing number.

3/C
V1
F0 Continue to general notes.....
F0 5/L01/M V13/C
L015-S/L01/M1143
A-SM
05/S03
Y570

20
CM D-X1
DM 03

34
STORAGE
1.013 S1 FW
S

S
S
V13/C04/S03

C
C S
F05

C
/L0 REFERENCE MODELS
1/D
20 V13/C06/S01

90
MODEL NUMBER VER MODEL NUMBER VER

10
F05 F05/L01/D21
/L0
CIRCUIT 5 FROM AMP 3 1/D GAD-STJV-ARC-PJW-Z03-MOD-010101 43 GAD-STAS-FPR-L01-STW-MOD-000002 71
V13/C04/S04 16

T
V14/C GAD-STES-SST-PJW-Z03-MOD-000001 09 GAD-STAS-FPR-PJW-STW-MOD-000007 131
07/S01 Ca
STAIR FA ble T E
F05F- 010 GAD-STJV-FAS-PJW-Z03-MOD-000001 GAD-STAS-ELE-L01-STW-MOD-000002
L0 IM VE /A ATRIUM B.O.H. /L0 01
03 55
AC
F 1-SA 5 & F/A 1.498 1/M

10000
Cables T/A F0505/L0 -SFD 28 CM
GAD-STJV-CGA-PJW-STW-MOD-000000 189
2
CM /L02 /M0 06
-
DM /M02 1
V13/C06/S03 GAD-STJV-CGA-PJW-STW-MOD-000006 103
IM F05 40
/L0 60 GAD-STAS-BWR-PJW-STW-MOD-000001 385
1 /D1
9
Ca CLIENT REFERENCE DRAWING NUMBER: RFI. REFERENCE NUMBER:
V13 ble FW
/C0 STAIR A2-620A/620D _C01, F5-620A/620D_C01, A7-200 _ C01 GAD-STAS-RFI-BMS-000005
FR 5/S F/B S AJ
OM 01 &T Cables T/A

T
FA /A GAD-STAS-ELE-L01-Z03-DWG-004012, F7-120_C01
V E-5 V14/C05/S01
STAIR GAD-STAS-FIS-PJW-STW-DWG-000001 & DWG-000002
AR Cables T/A
V0 GAD-STAS-MEC-L01-Z03-DWG-001012
Ca 7/C
ble 02
F/B /S02

T
GAD-STAS-FPR-L01-Z03-DWG-001012, N2-620A
GALLERY 101 &T
/A GAD-STAS-FIS-PJW-STW-DWG-000011 & DWG-000012
1.010 29
THIS ROOM IS DETECTION 60
BY VESDA SYSTEM
REFER DWG NO :
F05/L01/M21
Y560
56 05 REVISED AS PER COMMENTS 30-01-2024 JTK SAU SUJ
GAD-STAS-FIS-L01-Z03-DWG-002012 04 REVISED AS PER COMMENTS 14-11-2023 JTK SAU SUJ
S 03 REVISED AS PER COMMENTS 31-08-2023 JTK SAU SUJ
F05/L01/D22 C
02 REVISED AS PER COMMENTS 03-07-2023 JTK SAU SUJ
01 REVISED AS PER COMMENTS 02-03-2023 JTK SAU SUJ
00 ISSUED FOR APPROVAL 17-01-2023 JTK SAU SUJ
NO. ISSUE DESCRIPTION DATE DRAWN BY CHECKED BY APPROVED BY
TH PROJECT OWNER
IS
R
GA BY OOM
D-S VE IS
TA REFE SDA DET
S-F R D SY EC
FROM AMP-14 IS- S T
L0 WG TEM ION F05
1-Z NO

10000
C /
03 L03
S -DW : F0 /M2
F05 5/L01
F05/L01/M02 G- V13 4
DEPARTMENT OF CULTURE

FOR CONTINUATION REFER DWG NO:


F05/L01/M03 00 /C0 /L0 /D23 V13
1/D

GAD-STAS-FIS-L01-Z03-DWG-001013
V13/C04/S01 F05/L01/M04 F05/L01/M05 20
12 4/S 24 C /C04
L01-SA-SFD-26 FOR VESDA RPS-09 0 7 / S08
F05/L01/M06
V13/C04/S02
F05/L01/M11
F05/L01/M12
AMP-14
AMP AMP RPS
RPS-08
AMP
FAVE-5
FAVE DM DM DM RPS DM
DM DM DM F05/L01/M07
F05/L01/M08
FOR VESDA
C S RI
AND TOURISM
CM DM CM DM
L01-RA-SFD-24
F05/L01/M09
F05/L01/M10

AMP-13
AMP-15 GALLERY 101 VESTIBULE
L01-RA-SFD-23 V13
CM DM CM DM IM L01-SA-SFD-25 F05/L01/D01 1.010 1.017 / C03
06
FAVE SET
FROM IT TRUNKING F/B
F05/L01/M15 CLO / S05
ELECTRICAL F05/L01/M16 IM CM FROM FFTP-3
AV F05/L01/D02 CLOSET F05/L01/M17 1.012
1.011 F05/L01/M18 PROJECT MANAGER
FOR ACS
C

IM
C

F05/L01/M01
TURNER CONSTRUCTION
S

-INTERNATIONAL LLC
F05
/L0
3 TO
L1M
Y550 P.O. BOX 890, ABU DHABI, UAE
TEL: +971 2 6500 888
FOR CONTINUATION REFER DWG NO:
GAD-STAS-FIS-L01-Z01-DWG-001004

FR
OM
AM CONSULTANTS

E-5
P-1
4

V
TH
GEHRY PARTNERS, LLP.

FA
IS
R

OM
GA BY OOM V13

01
FR
D-S VE IS 47 /C0
0 20
ARCHITECT

3/D
TA REFE SDA DET 3/S
0
C 30
4

/L0
S-F R S E
IS- DW YST CTIO F

F05
3 RI
AMP-1 L0 G EM F 05/L 12541 BEATRICE STREET LOS ANGELES, CALIFORNIA 90066 USA
FROM N F0505/L003/D1

IM
1-Z NO TEL: 310-482-3000
03 ELECTRICAL /L0 3/D1 01
-DW : 1.014 3/D 02
103

RI
G-
00
20
12
F05
S C ARUP
V13

10000
/L0
V13 3/M
23
/C0
3/S0
ENGINEER
/C0 6
4/S S
IM

10 OPEN WORKSPACE 900 WILSHIRE BLVD., 19TH FLOOR LOS ANGELES, CALIFORNIA 90017 USA
CM B
DM 1.721 TEL: 310-578-4400
01/S03 CM

F0505/L0SFD-2-27
V13/C

F /L 3/M 5
DM

F0505/L0 03/M0 01
F RA- FD

/L0 3/M0 2
3/M 3
STORAGE CONSULTANT-OF-RECORD

- -S

04
L01 1-SA
1.499 18
80
ARUP GULF LTD

L0
F

0
F0505/L0

79
F0

0
450

59
01/S04 1/D04 LOST & FOUND 01/S01 1/D11 F05 5/L03 /L0 3/D9
V13/C F05/L0
1080
V13/C F05/L0 F
F0505/L0 /L0 /D99 3/D 7
98 12TH FLOOR,
/D03 C /L 1/M 3/D

00
1.412
0 1 RI 100
V11/ 1010 F05/L 1830 SFD01/M222
31 ABU DHABI UNIVERSITY TOWER,

19
C0 30
3/S0 SIGN & STANCHION STORAGE C AL MUROOR STREET,
1570

(NO3
1150

2 F0 S
1.415 CM ) L F05/5/L01 RI PO BOX 78907,
L01-S05/L01/M1290

DM 01- L01 /M2 B V13 PANTRY ABU DHABI, UNITED ARAB


IM SA /M2 4 V13 /C0
F /L01/M

TR -SF 5
F05

/C0 3/S 1.714 EMIRATES


FR UNK
A-SMD

FF CM
D-0 3/S CONFERENCE ROOM 07
OM IN 7 C
01/S02
TP 02 1.723
-3
FF G T / V13/C
D M SUPERVISION CONSULTANT
GROU

TP B 1/D05 Y540
-02 CM D

P F05/L0
CORRIDOR 1100 C
P SALE 93

1.420 V13
FOR5/L

ICE F
F 05/L
F0 0

OFF RI /C0
ERSHIP
S

F0505/L0303/D0 3/S
1.4
mo

MEMB 1.492
1450

PARSONS BRINCKERHOFF LTD


M

ACS/M21

03
CM

1670 IM
/L0 /D0 2 V13
S MAN
ke

3/D 3 /C0
1

RI S
Ov

RI 3/S
1/D10 04
err

IT
F05/L0 1/D12 50 F
F0505/L0
08 B
ABU DHABI
F05/L001/D07

AGER
id

1330
F05/L

1.410
CORR 14

F05/L/L001/D13 1/D14
60
F05/L0 /L0 3/D1

RI
2410

CASH HANDLING GE
STORA1 5

20
F0 A MEMBER OF THE WSP GROUP
1.4

3/D 9
1.431 01/S10 1/M26 20

20
1/D06
IDOR

1.49 V13/C F05/L/L001/M27 -06

00
20 P.O. BOX 447445, SKY TOWER, LEVEL 36
14

50

39
F05 -RA-SFD
10

F
F04 04/L0 RI 01/S09 L01 OFFICE UNIT 3602, REEM ISLAND, ABU HDHABI, UAE
920 V13/C COPY ROOM TEL: +971 2 652 9222. FAX: +971 2 677 9772
/L0 2/D 1 /D08 1/D15 TECHNOLOGY LAB
F05/L0 F05/L0
2/D 95 M
CM D 11 1.722
1.726
01/S08 S
96 30
MAIN CONTRACTOR:
S

R V13/C 28
1/D09 RI B
720

I 60
90 F05/L0
C

C S
12 C V13 RI
V13 / C03 F
01/S07 6290 01/S11 RI
F 05/L

0
V13/C DEPUTY DIRECTOR /C0 /S0
01/S05 V13/C F0505/L0 03/D9

59
720

3 9 S

10000
V13/C C 1.718 /S0 F /L0 3/D9 4
INFORMATION & MEMBERSHIP SERVICES

F 1 F0505/L03 3/D 5 S
F0505/L0
B
17 /L0 /D1 96

50
/L0 3/D0 90 3/D 7 B F
600 DIR C F 05/L

37
3/D 5 18
NEW ECTO F0505/L0303/D9

0
80
06 F0
M RO F05 5/L03 RI IM /L0 /D9 1
SUB CONTRACTOR:
1.71 EDIA F /L0 /D1 S 3/D 2
93
7R 3/D 5 F05

10
I
16 40 F05 /L03/ TEL:04-3389154

20
90 B
1.417

/L0 D21 RI

RI
57 3/D
F0 0
22 FAX:04-3389155
F05 5/L03
RI

RI
01/S06

OM
THIS R /L0 /D0 20
V13/C 01/S12 OOM P.O. BOX 13164, DUBAI U.A.E.

6 RO
3/D 7 4 0
V13/C BY VE IS DETECTIO 08 RI

1.70 REST
SDA S www.alshafar.com
REFER YSTEM N

10
GAD-S 57 V13

L
D W V13 0

20
G NO :

RSA
TAS-F S F /C0
IS-L01
-Z03-D /C0 V13 F0505/L0 3/S

10
4/S 10

IVE
WG-00 09 B /C0 D
FAM IRECT /L0 3/D1 S FIRE FIGHTING CONTRACTOR:
WOMEN'S RESTROOM 3/S11

20
2012 3/D 1

UN
ILY OR 12 B
1.710 PR OF

S
1.71 OGR F
F0505/L03

AM
S 3 AM

GR
S /L0 /D1 S
C

B 3/D 3 S

RO
0
14
Y530

85
B

1.71 BLIC P
S

RI B

0
96
VESTIBULE VESTIBULE 18

6
10

PU
F 70
1.406 S F0505/L03

12
1.403

450
OF
/L0 /D0 PROJECT NAME

30
RI B RI
880 F 3/D 9
F0505/L03

IM
0
OR

35
10
800

F05/L0 /D JANITOR'S CLOSET

ECT
V13/C01/S
16 F05/L033/D 45 /L0 /D2
3/D 7 1.707 CORRIDOR
46 S
GUGGENHEIM ABU DHABI

DIR
F05/L03/D C V13/C01 2580 S 28
/S 70 1.728
15 F05/L03/D
810

47 44 VESTIBULE
B 0 B STUDIO LAB 3 S
C RI 1140 1.705 35
80
RI
F 1.725 B
V13/C01/S14 PROJECTION ROOM F0505/L03
720

810

1.404 V13/C01
/S19 /L0 /D8
3/D 9 ZONE
1280

760
90
GROUP ENTRY
V13/C01/S C 1.401 S CULTURAL DISTRICT, SAADIYAT ISLAND
18 S
ON B
C TI MEN'S RESTROOM B
ETE T HIGH V13/C01

0
D /S17 1.703 F05

95
IS A S F0 SECTOR NO. PLOT NO.
OM
RO SYST
EM F05 5/L03 F05 /L03/D
I S B /L0 /D25 /L0 23
TH ESDA EVEL NO : 004 3/D RI 3/D
-002 V13 26 24
BY V L
ER
D WG
01-D
WG /C0
3 /S1
RI SDN1 P7
REF -L01-Z 4470 FOR CONTINUATION REFER DWG NO: 3 V13
/C0
FI S GAD-STAS-FIS-L01-Z03-DWG-001011 3
AS-
RI

/S1 S

10
D -ST 2

20
A F05/L03 B
G VESTIBULE PROJECT DESCRIPTION
F05/L03 /D48
IM
/ 1.708

LEGENDS:
SYMBOL DESCRIPTION MODEL NUMBER
GENERAL NOTES:
FIRE ALARM SYSTEM
2 core x 1.5sq. mm. 2hr FIRE RATED CABLE FOR LOOP
DETECTION THROUGH 25mm PVC/GI CONDUIT & TRUNKING MODERN AND CONTEMPORARY
01. FIRE ALARM CABLE SHALL BE OF FIRE RATED TYPE. 2 core x 2.5sq. mm. 2hr FIRE RATED CABLE FOR SPEAKER

1 FIRE ALARM SYSTEM PLAN LEVEL 01 (B03 02 OF 08)_SHEET 12


FAVE
ADDRESSABLE FIRE ALARM CONTROL PANEL
Mounting Hight : 1800mm from top
TR-2100ECSR
TR-2100ECSB
02. PROVIDED DEDICATED AC 230V OUTLETS WITH PROPER ISOLATOR / MCB FOR FIRE ALARM PANELS
WITH LETTES " FIRE ALARM SYSTEM DO NOT SWITCH OFF "
EVICES THROUGH 25mm PVC/GI CONDUIT & TRUNKING
2 core x 1.5sq. mm. 2hr FIRE RATED CABLE FOR TELEPHONE
ART MUSEUM
BATTERY CABINET 03. PROVIDED DEDICATED AC 230V OUTLETS WITH PROPER ISOLATOR FOR FAVE, AMP, PSU, FFTP &
BATT Mounting Hight : Bottom of FAVE panel
RBB / AB-55 JACK THROUGH 25mm PVC/GI CONDUIT & TRUNKING
RPS.
REMOTE ANNUNCIATOR 2 core x 2.5sq. mm. 2hr FIRE RATED POWER CABLE DRAWING TITLE
SCALE: 1 : 100 FARP Mounting Hight : 1800mm from top
TR-RD2R 04. FIRE ALARM INTERFACING MODULES ARE OF VOLT FREE CONTACT SUITABLE FOR 24V AC OR 24V
DC.
THROUGH 25mm PVC/GI CONDUIT & TRUNKING

RPS
HIGH VOLTAGE (240V) INTELLIGENT DISTRIBUTED POWER MODULE
Mounting Hight : 1800mm from top
TR-RPS1 05. THIRD PARTY INTERFACING WILL BE PROVIDED AFTER AVAILABILITY OF THIRD PARTY SYSTEM
DRAWINGS.
2 core x 1.5sq. mm. FIRE RATED CABLE FOR NETWORKING
CABLE THROUGH 25mm PVC/GI CONDUIT & TRUNKING FIRE ALARM SYSTEM PLAN
REMOTE MOUNTING KIT FOR LOOP EXPANDERS
FLEC Mounting Hight : 1800mm from top
ADDRESSABLE SMOKE DETECTOR
TR-5815RMKR 06. ALERT SIGNAL FROM FIRE FIGHTING & SPRINKLER SYSTEM TO BE INTERFACED WITH FIRE ALARM
SYSTEM.
07. FOR DEVICE & LOOP DETAILS REFER SCHEMATIC DIAGRAM.
LEVEL 01 (B03 02 OF 08)
TR-PHOTO-W
Mounting Hight : ceiling & slab mount typical 08. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE. ZONE LEGEND
ADDRESSABLE FLOOR VOID SMOKE DETECTOR WITH REMOTE INDICATOR TR-PHOTO-W+ 09. ALL MATERIAL, CODE & EQUIPMENT'S ARE SUBJECT TO APPROVED MATERIAL SUBMITTAL.
Mounting Hight : below raised floor typical TR-RA100Z 10.DEVICE INSTALLATION DETAILS SHALL BE SUBMIT SEPARATELY PLEASE REFER DWG NUMBER: DRAWING NUMBER REVISION NO.
ADDRESSABLE CEILING VOID SMOKE DETECTOR WITH REMOTE INDICATOR TR-PHOTO-W+ GAD-STAS-FIS-PJW-STW-DWG-000002
FIRE ALARM ZONE PART OF WET SPRINKLER ZONE
GP's preference is to locate off Mounting Hight : above ceiling & slab mount typical TR-RA100Z VOICE EVACUATION SYSTEM
of exposed structure where ADDRESSABLE FIXED TEMPERATURE AND RATE OF RISE THERMAL DETECTOR
TR-HEAT-ROR-W
01. VOICE EVACUATION CABLE SHALL BE OF FIRE RATED TYPE.
The Design Architect’s review is only for general conformance with the established aesthetic
This Contractor submittal has been reviewed by the Design Architect for general
design intent of the Project. Corrections and or comments noted on the shop drawings during
conformance
GAD-STAS-FIS-L01-Z03-DWG-001012 05
Mounting Hight : ceiling & slab mount typical 02. PROVIDED DEDICATED AC 230V OUTLETS WITH PROPER ISOLATOR / MCB FOR VOICE EVACUATION this review do not with architectural/aesthetic
relieve design intent
the General Planner (Executive only,
Architect) andand not for technical
its consultants, as the
possible to minimize exposed PANELS WITH LETTERS
FIRE ALARM ZONE PART OF PRE-ACTION SYSTEM ZONE adequacy,
established accuracy
Architect and/orof Engineer
completenessof Recordof the detailed
for the Project,design, which remains
or the construction the
contractor
ADDRESSABLE COMBINED PHOTOELECTRIC SMOKE DETECTOR WITH
conduit routing. Contractor to HEAT SENSOR Mounting Hight : ceiling & slab mount typical
TR-PHOTO-T-W " VOICE EVACUATION SYSTEM DO NOT SWITCH OFF " responsibility
from compliance with of others.
any of its or their contractual obligations, or applicable laws, codes and
regulations. The Design Architect’s review of a single item shall not include review of an assembly
confirm if feasible.
ADDRESSABLE PHOTOELECTRIC DUCT SMOKE DETECTOR TR-PHOTO-R-W
03. THE FIRE ALARM SYSTEM SHALL BE INTERFACED WITH VOICE ALARM AND PAVA SYSTEM.
04. FOR DEVICE & CIRCUIT DETAILS REFER SCHEMATIC DIAGRAM of A
which the item is a component.
No comments. SubmittalThe construction
is in general contractor
conformance is responsible for: dimensions
with architectural/aesthetic design intent. to be
DATE SCALE
+ TR-DNR
confirmed and correlated at the jobsite; information that pertains to the fabrication process or to
HD
EXPLOSION PROOF HYDROGEN DETECTOR WITH RELAY MODULE
Mounting Hight : slab / wall mount typical
DRAEGER
ABBREVIATIONS
means, methods,
Proceed techniques, sequences
in accordance
Bthat of allarchitectural/aesthetic
with other trades; and performing
and procedures
with comments.
design intent all
ofgeneral
Submittal is in construction;
worktoinincorporation
subject
coordination
conformance
a safe andofsatisfactory
with
manner.
Design Consultant's
of the work
comment(s)
30-01-2024 As
EXPLOSION PROOF FLAME DETECTOR FIK-IR3-HD-AS11+ on the submittal. Contractor must incorporate and re-submit for record.
FD Mounting Hight : slab / wall mount typical
EXPLOSION PROOF HEAT DETECTOR
FIK-TMO-S01
27121-0 +
T/A TO ABOVE F/A FROM ABOVE
C
NO EXCEPTIONS
Revise and Resubmit -TAKEN
REJECTED
Submittal is NOT consistent with architectural/aesthetic design intent
and must be revised and re-submitted.
indicated
HDP Mounting Hight : slab / wall mount typical 06116317-001 T/B TO BELOW F/B FROM BELOW REVISE AND RESUBMIT
MAKE CORRECTIONS NOTED
REMOTE INDICATOR D Reviewed - delegated design submittal is generally consistent with architectural/aesthetic ADM PROJECT NUMBER:
RI TR-RA100Z FAVE FIRE ALARM & VOICE EVACUATION PANEL FARP FIRE ALARM REPEATER / ANNUNCIATOR PANEL design intent.
Mounting Hight : ceiling / wall mount typical NOT REVIEWED
SUBMIT SPECIFIED ITEMS
ADDRESSABLE MANUAL PULL STATION WITH BACK BOX TR-PULL-DA +
Mounting Hight : 1100mm from top
ADDRESSABLE MANUAL PULL STATION WITH BACK BOX, WEATHER
SB-I/O
TR-PULL-DA +
PSU

PH
POWER SUPPLY UNIT

PHONE HANDSET CABINET


AMP

CBS
AMPLIFIER

CENTRAL BATTERY SYSTEM


E Rejected
GEHRY PARTNERS, LLP
GEHRY PARTNERS, LLP
B1N-2018-005679
PROOF Mounting Hight : 1100mm from top SB-I/O + STI-3150 GUGGENHEIM ABUABU
GUGGENHEIM DHABI
DHABI MUSEUM - 2008-009
MUSEUM - 2008-009
ADDRESSABLE RELAY MODULE RS ROLLER SHUTTER ACV ALARM CHECK VALVE
CM TR-RELAY
Mounting Hight : 2700mm from bottom / above ceiling
SCH SCHEMATIC DIAGRAM ASEF ATRIUM SMOKE EXHAUST FAN Cordell Sheppard 03/01/2024
BY:__________________________________DATE:__________________________
OFFICIAL USE ONLY
ADDRESSABLE DUAL MONITOR MODULE
DM Mounting Hight : 2700mm from bottom / above ceiling
TR-MONITOR-2
ZCV ZONAL CONTROL VALVE SEF SMOKE EXHAUST FAN
ISOLATOR MODULE
IM TR-ISO EF EXHAUST FAN SPEF SPECIALTY SMOKE EXHAUST FAN
Mounting Hight : 2700mm from bottom / above ceiling GP Comments:
WSP ELE: BD RP BEAM DETECTOR & REFLECT PLAT ALPHA2000 GSEF GALLERY SMOKE EXHAUST FAN TEF TUNNEL EXHAUST FAN Comments provided for design intent/aesthetic purposes only.
1. Contractor shall submit typical installation WALL MOUNTED SOUNDER FLASHER, WEATHER PROOF
Mounting Hight : 2000mm from center
TR-P2RK SPF STAIR PRESSURIZATION FAN HPE HOISTWAY PRESSURIZATION FAN
1. Per design build specification requirements, Contractor to validate
of all fire alarm devices with elevation and WALL MOUNTED FLASHER
Mounting Hight : 2000mm from center
TR-SWL + SBBRL
AHU AIR HANDLING UNIT FCU FAN COIL UNIT quantity and location of speakers to meet code requirements.
section details for approval as per WALL MOUNTED FLASHER, WEATHER PROOF
SWK
VESDA VERY EARLY SMOKE DETECTION ALARM FAHU FRESH AIR HANDLING UNIT
2. Review of speaker layout subject to speaker location confirmation
Mounting Hight : 2000mm from center
specification 28 31 00 clause 1.10 C. AMP ECS 50W AMPLIFIER
TR-50W /
AV SPEAKERS NOT IN ASU SCOPE & DEVICES ARE SHOWN
and AV shop drawing submission.
TR-DUAL50W LABELING OF DEVICES AS FOLLOWS: LEVEL & ZONES REFERENCE AS FOLLOWS:
2. All third party interface with FACP including CEILING MOUNT SPEAKER TR-SPCWL +
AS INDICATIVE ONLY
C Mounting Hight : ceiling mount typical SBBCWL
FX / LX / DXX - DETECTORS
LEVELS (FLOOR) AREA (ZONES) SYMBOL DESCRIPTION
PAVA system shall be coordinated and CEILING MOUNT SPEAKER WITH FLASHER TR-SPSCWL +
FX / LX / MXX - MODULES
TX / CX / JXX - TELEPHONE JACK GFR > GROUND FLOOR Z01 > ZONE 1 C
C S NOMINAL LENGTH 1.7m LINE ARRAY LOUDSPEAKER
provide details. Mounting Hight : ceiling mount typical
WALL MOUNT SPEAKER
SBBCWL
TR-SPWL +
VX / CX / SXX - SPEAKERS GFM > GROUND MEZZANINE FLOOR Z02 > ZONE 2
L01 > LEVEL 1 FLOOR Z03 > ZONE 3
3. Amplifier sizing, final tapping detail shall be Mounting Hight : 2000mm from center SBBSPW
L1M > LEVEL 1 MEZZANINE FLOOR Z04 > ZONE 4
S B
CEILING LOUDSPEAKER
WALL MOUNT SPEAKER WITH FLASHER WEATHER PROOF DEVICE TYPE
submitted. Mounting Hight : 2000mm from center
SPSWK L02 > LEVEL 2 FLOOR
L2M > LEVEL 2 MEZZANINE FLOOR
Z05 > ZONE 5
AV
C
AV CONNECTION, TYPOLOGY C
FIRE FIGHTER TELEPHONE CONTROL PANEL
4. All SMD/SFD/EF/SF location and quantity FFTP Mounting Hight : 1800mm from top
TR-FFT DEVICE REFERENCE L03 > LEVEL 3 FLOOR S
WALL MOUNTED LOUDSPEAKER, WIDE COVERAGE
L3M > LEVEL 3 MEZZANINE FLOOR FW
shall be coordinate with approved HVAC PH FIRE FIGHTER HANDSET CABINET
Mounting Hight : 1800mm from top
TR-HSC LOOP / CIRCUIT
L04 > LEVEL 4 FLOOR
REFERENCE
drawing T FIRE TELEPHONE JACK
Mounting Hight : 1100mm from top
TR-FPJ L05 > LEVEL 5 FLOOR
PANEL REFERENCE L06 > LEVEL 6 FLOOR
CABLE TRUNKING
-- L07 > LEVEL 7 FLOOR 04 March 2024
FOR TRUNKING EXACT SIZE REFER PLAN Sarath Kurian

You might also like