General ADMAG TI Series

Specifications AXG Magnetic Flowmeter

GS 01E22A01-01EN

n GENERAL DESCRIPTION
The ADMAG TI (Total Insight) series AXG magnetic
flowmeter is a high-quality and highly reliable product
developed based on years of experience and
achievement, such as enhancement of application by
our proprietary dual frequency excitation method.
The AXG magnetic flowmeter is ideal for industrial
process lines like oil & gas, chemical, pulp & paper,
food & beverage, or metal & mining applications.
With outstanding reliability and ease of operation and
maintenance, developed on decades of field-proven
experience, the AXG will increase user benefits while
reducing total cost of ownership. Integral Flowmeter Remote Transmitter
• Size: 2.5 to 500 mm (0.1 to 20 in.)
• Lining: Fluorocarbon PFA, Ceramics tube
• Process connection: ASME, EN, AS, and JIS
Note: For AXG1A remote transmitter, read general specifications
(GS 01E22C01-01EN).
For AXFA11G remote transmitter, read general specifications
(GS 01E20C01-01E).

n FEATURES
Stable Measurement
Our own dual frequency excitation method realizes
stable flow measurement even under high flow noise Remote Sensor
in the fluid with highly concentrated slurry.

Multiple Inputs and Outputs Compliance with IEC61508


Maximum four inputs/outputs of current, pulse, and (optional specification)
status signals can be selected. Mass or calorie This product can be used in safety instrumented
calculation using temperature input is available. systems up to SIL2 in simplex configuration and SIL3
in redundant configuration.
Improved Operation and Monitoring
Function Communication Protocol
Operation authority level setting for ensuring safety, HART, BRAIN, Modbus, FOUNDATION Fieldbus,
process data trend display, display backlight flashing PROFIBUS PA, EtherNet/IP
(Squawk) function, and data store / restore function
with display unit internal memory or microSD card Refer to GS 01E21F02-01EN for FOUNDATION
are available. Fieldbus communication type
Refer to GS 01E21F02-02EN for EtherNet/IP
Improved Maintainability Communication Type
Diagnostic functions that contribute to preventive Refer to GS 01E21F02-03EN for PROFIBUS PA
maintenance of the plant are installed. Diagnosis of communication type
the device (verification function) that can be executed Refer to GS 01E22A11-03EN for pulp & paper
without demounting from piping, detection of the application type
process condition by monitoring the flow noise and Refer to GS 01E22A21-04EN for marine approval
electric conductivity of the fluid, electrode insulation type
deterioration diagnosis, electrode adhesion diagnosis,
and wiring connection diagnosis are available.

Yokogawa Electric Corporation GS 01E22A01-01EN


2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan © Copyright Apr. 2017 (KP)
Tel.: +81-422-52-4443 Fax.: +81-422-52-2018 26th Edition May 30, 2025 (KP)
2
n GENERAL n CONSTRUCTION
Measuring Principle: Use:
By applying the occurrence of electromotive force Use Specification
proportional to the flow velocity when fluid moves in
the magnetic field, the flowmeter can measure the Non explosion protection for the use in
flow velocity of conductive liquid. It calculates the non-hazardous area. Applicable to Integral
General- Flowmeter, Remote Sensor, or Remote
instantaneous flow rate, integrated flow rate, etc.
purpose Transmitter.
from the measured flow velocity. IP Protection Grade:
System Configuration: IP66/IP67, Type 4X (CSA)
Basic configuration: Sensor, Transmitter, Cable Temporary submersion is possible.
Applicable to Remote Sensor only.
Function Note: Urethane resin potting is applied in the
Sensor Detects the flow velocity terminal box of a remote sensor. Signal and
Transmitter Amplifies a sensor and converts signals. excitation cables (when optional code L### is
not selected, cable length is each 30 m) are
Signal cable (for flow signal), excitation
Cable (*) pre-wired and waterproof glands with union
cable (for coil excitation)
joints are attached at factory.
*: Necessary for Remote type with construction Performance:
separated to a sensor and a transmitter. Conforms to continuous immersion under
The excitation cable is to be supplied by customer Submersible
the following test condition.
except for Submersible-Use. Test Condition:
Main Element of Sensor: 1 month with fresh water and 50 m under
Function the water surface (hydraulic pressure 0.5
MPa). However, adverse conditions such
Lining (*1), Electrodes, Grounding as sewage and seawater are excluded.
Wetted Part
Devices (*2), Adapters for hygienic. Protect the cable by appropriate means,
Flanges, Housing, Excitation coil, such as protected separately with conduit
Non-wetted Part Measuring pipe (excluding ceramics piping.
tube) IP Protection Grade: IP68
*1: including ceramics tube. Explosion protection for the use in hazardous
*2: grounding ring plate, metal hat grounding ring, area. Applicable to Integral Flowmeter,
grounding ring for wafer type replacement model Explosion
Remote Sensor, or Remote Transmitter.
grounding ring electrode, built-in grounding electrode Protection
IP Protection Grade:
Note: Grounding devices are for taking the reference electric Read "Explosion Protection".
potential from the process fluid in measuring the
electromotive force, and are fixed (or built-in) at two Equipped with piping adapters following
locations, upstream and downstream of the flow. They hygienic standards. Applicable to Integral
are unnecessary when the reference potential is taken Hygienic Flowmeter, or Remote Sensor.
from installed piping. For details of grounding, read IP Protection Grade:
"Cautions on Selection and Installation". IP66/IP67, Type 4X (CSA)
Main Element of Transmitter: Equipped with piping adapters following
Display unit, Setting keys, Amplifier unit (including hygienic standards.
Hygienic
I/Os and power supply unit) with
Explosion protection for the use in hazardous
area. Applicable to Integral Flowmeter, or
Explosion
Remote Sensor. (Except optional code 3A.)
Protection
IP Protection Grade:
Read "Explosion Protection".
Blow line These specifications are for pulp & paper
application type. For details, please refer to
Circulation/
GS 01E22A11-03EN.
extraction
line

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
3
Construction: Process Connection:
Two types of Integral and Remote type. Wafer, flange, union joint (screw type, welding type),
Type Construction clamp, union, and welded joint type are available.
Integrated structure of a sensor and a
For the availability of lining and size range, read
Integral type "MODEL AND SUFFIX CODE".
transmitter.
Separated structure of a sensor and a Type Process connection
Remote type transmitter, which are connected by a ASME Class 150, Class 300
signal cable and an excitation cable (*). EN PN10, PN16, PN40
Wafer
JIS F12, 10K, 20K
*: To be supplied by customer except for Submersible-
JPI Class 150
Use.
Combinable Transmitter: ASME Class 150, Class 300, Class 600
EN PN10, PN16, PN25, PN40
Remote Sensor Flange AS Table D, Table E
Remote Transmitter
Size JIS F12, 10K, 20K
2.5 to 400 mm JPI Class 150
AXG4A, AXG1A, AXFA11G
(0.1 to 16 in.) Screw Type:
500 mm 1/4 NPT (size 2.5 to 5 mm / 0.1 to 0.2 in.)
AXG1A, AXFA11G 3/8 NPT (size 10 mm / 0.4 in.)
(20 in.)
R 1/4 (size 2.5 to 5 mm / 0.1 to 0.2 in.)
Note 1: When changing the combined transmitter, R 3/8 (size 10 mm / 0.4 in.)
readjustment of the meter factor by actual flow Union Joint
Welding Type:
calibration is necessary to ensure accuracy. Outer Diameter of Welding Union Joint:
Note 2: For AXG1A remote transmitter, read general 18.5 mm / 0.73 in. (size 2.5 to 5 mm / 0.1
specifications (GS 01E22C01-01EN). to 0.2 in.)
For AXFA11G remote transmitter, read general 22.5 mm / 0.89 in. (size 10 mm / 0.4 in.)
specifications (GS 01E20C01-01E).
Note 3: When combining explosion protection AXG remote Tri-Clamp
sensor with general-purpose AXG4A remote DIN 32676 Clamp
Clamp
transmitter, low conductivity detection may not ISO 2852 / SMS 3016 Clamp
perform properly. ISO 2852 Clamp (for JIS G3447 Piping)
Note 4: When selecting the optional code E21 for the DIN 11851 Union
AXG4A remote transmitter, unify either general- ISO 2853 Union
purpose or explosion protection for both of the AXG Union SMS 1145 Union (Open groove packing
remote sensor and the AXG 4A remote transmitter. type)
Note 5: The remote sensor for Japan Flameproof can be ISO 2853 Union (for JIS G3447 Piping)
connected only with a remote transmitter authorized DIN 11850 Piping Butt Weld Joint
by Yokogawa Electric Corporation. Butt Weld Joint ISO 2037 Piping Butt Weld Joint
Maximum Cable Length: JIS G3447 Piping Butt Weld Joint
100 m (328 ft) for AXG4A remote transmitter
Electrode Construction:
200 m (656 ft) for AXG1A and AXFA11G remote
transmitter External insertion type or internal
PFA Lining
5 m (16 ft) when using with Marine Approval Type insertion type (*)
Electrode integrally sintered type
Ceramics Tube
(Platinum- Alumina Cermet)
*: Internal insertion type is for models with Hygienic or
Hygienic Explosion Protection, size 500 mm (20 in.),
or ASME Class 600 flange high pressure type.
Grounding Device Construction:
Grounding Ring
Ring flat plate with mounting bracket
Plate
Metal Hat Grounding ring with hat shape, with
Grounding Ring mounting bracket
Grounding Ring
For Wafer Type Ring-shaped short pipe grounding ring,
Replacement with mounting bracket
Model
Electrode is inserted into ring-shaped
Grounding Ring
short pipe with PFA lining, with mounting
Electrode
bracket
Built-in Grounding Electrode is inserted on the inner
Electrode surface of the measuring pipe
Wetted Part:
Wetted Part Material
Fluorocarbon PFA, Ceramics (*)
Lining * : Alumina ceramics (99.8%)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
4
Wetted Part Material Wetted Part Material
Stainless steel 316L, Nickel alloy (*), Installed Pipe
Platinum- Iridium, Tantalum, Titanium, Standard:
Electrode Tungsten carbide, Platinum-Alumina None (supplied by customer)
cermet Optional (for wafer type, with bolts,
Gasket (Note)
* : ASTM B574 UNS N10276 or nuts, and gaskets):
ASME SB-574 UNS N10276 BSC: Chloroprene rubber (CR)
Grounding Ring Plate BSF: PTFE-sheathed non-asbestos
Stainless steel 316L, Nickel alloy (*), Titanium joint sheet
* : ASTM B575 UNS N10276 or Process Connection (Clamp):
ASME SB-575 UNS N10276
HJA: Stainless steel F304
Metal Hat Grounding Ring Optional W2 (Hygienic Connection
Stainless steel 316L Parts):
Grounding Device Grounding Ring For Wafer Type Clamp: Stainless steel SCS13 (*1)
Replacement Model Ferrule:
Stainless steel F316L Size 15 mm (0.5 in.): Stainless
Grounding Ring Electrode steel 316L
Platinum-Iridium, Tantalum Size 25 to 125 mm (1 to 5 in.):
Built-in Grounding Electrode Stainless steel 304
Platinum-Iridium, Tantalum HJB: Stainless steel F316L
PFA Lining Adapters for Optional W2 (Hygienic Connection
• General-purpose, Submersible, and Hygienic Parts):
Explosion Protection (excluding ASME Clamp: Stainless steel SCS13 (*1)
Class 600 flange high pressure type) Ferrule: Stainless steel 316L
Standard: None (not necessary) HAB, HDB, HKB: Stainless steel F316L
Optional (for plastic piping): Process Connection (Union):
GA: Fluororubber JJA: Stainless steel F304
GC: Acid-resistant fluororubber JJB: Stainless steel F316L
GD: Alkali-resistant fluororubber JDB, JKB, JSB: Stainless steel F316L
• ASME Class 600 flange high pressure type Process Connection (Butt Weld Joint):
Standard: Fluororubber (FKM) (O-ring) KJA: Stainless steel F304
• Hygienic, and Hygienic Explosion Protection KJB, KDB, KKB: Stainless steel F316L
Gasket A: (See the figure below) *1: JIS standard casting material
Standard: Ethylene propylene Screw Union Joint:
diene rubber (EPDM) GUN, GUR: Stainless steel F316L
Optional: Union Joint for Welding Union Joint:
GH: Silicone rubber Ceramics Tube GUW: Stainless steel F316L
3A: ‌Ethylene propylene diene Note: Contact YOKOGAWA office if plastic
rubber(EPDM) union joint is required.
Gasket B: (see the figure below)
Optional: Note: The description is about the material of gaskets
W2: supplied with flowmeter, to be used between the
Size 15 to 100 mm / 0.5 to 4 in.: sensor pipe and grounding ring or the process flange.
Ethylene propylene diene This includes whether gaskets are necessary, or
rubber (EPDM) whether gaskets should be supplied by customer.
Size 125 mm (5 in.): For details of gaskets, read "Cautions on Selection
Silicone rubber and Installation" and "Optional Code".

Gasket (Note) W2 and GH: Silicone rubber Non-wetted Part Material:


5 4 21
Sensor Terminal Box:
Low copper aluminum alloy EN AC-43400
Transmitter Housing:
Clamp
Low copper aluminum alloy EN AC-43400
3 Sensor Housing:
Union Size Material
2.5 to 15 mm (0.1 to 0.5 in.) Stainless steel SCS11 (*1)
21 25 to 125 mm (1 to 5 in.) Stainless steel 304
Welded joint 150 to 500 mm (6 to 20 in.) Carbon steel SPCC (*2) or
its equivalent
21 F01.ai *1: JIS standard casting material
1: Gasket A 2: Adapter *2: JIS standard or JIS standard-based material
When selecting optional code W2
3: Gasket B 4: Clamp Mini-flange (subject to pressure in wafer type):
5: Ferrule PFA Lining
Ceramics Tube
Standard: Size Material
Fluororesin with ceramic fillers 150 to 200 mm (6 to 8 in.) Carbon steel A105 (*3)
(Valqua #7020)
Note: In the wafer type other than the above, there is no
Optional (for plastic piping):
mini flange because the measuring pipe and the
GA: Fluororubber
connecting part have a one-piece casting structure.
GC: Acid-resistant fluororubber
GD: Alkali-resistant fluororubber
Optional (for metal piping):
GF: Fluororesin with alkali-resistant carbons

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
5
Flange: Submersible (Remote Sensor):
Process Connection Code Material Standard Coating:
B## Coated Part Coating Specification
D## Stainless steel F304 Sensor housing
E## Sensor flanges Non-tar epoxy resin solvent
P## Stainless steel F316 Sensor terminal box coating
C## Carbon steel A105 (*3) (incl. cover)
*3: ASTM standard forged material Hygienic, and Hygienic with Explosion Protection
(Integral Flowmeter, and Remote Sensor):
Measuring Pipe: Standard Coating:
• PFA Lining
General-purpose, Submersible, and Explosion Coated Part Coating Specification
Protection (excluding ASME Class 600 flange high Sensor housing
No coating
pressure type): Adapter for piping
Size Material Sensor terminal box
(for remote type,
2.5 to 15 mm (0.1 to 0.5 in.) Stainless steel SCS13 (*4) Polyester resin powder
incl. cover)
25 to 125 mm (1 to 5 in.) Stainless steel CF8 (*5) coating
Transmitter housing
150 to 500 mm (6 to 20 in.) Stainless steel 304 (incl. cover)
*1: No coating for General-purpose and Explosion Protection
ASME Class 600 flange high pressure type with stainless steel flanges in sizes 2.5 to 125 mm (0.1 to
5 in.). Coating is done to sizes 150 mm (6 in.) and more,
Size Material
or to carbon steel flanges.
25 to 100 mm (1 to 4 in.) Stainless steel 304 *2: Rugged coating is for applications which need salt
tolerance resistance, alkali resistance, acid resistance,
and/or weather resistance. Epoxy resin undercoating
Hygienic and Hygienic Explosion Protection twice and polyurethane resin overcoating once are
Size Material performed to the same area as standard coating.
15 to 25 mm (0.5 to 1 in.) Stainless steel SCS13 (*4) Coating Color:
32 to 125 mm (1.25 to 5 in.) Stainless steel CF8 (*5) General-purpose, Explosion Protection, Hygienic,
*4: JIS standard casting material and Hygienic Explosion Protection:
*5: ASME standard casting material Mint green (Munsell 5.6BG3.3/2.9 equivalent)
Note: Read "Lining Material" for ceramics tube, which is a Submersible:
wetted part material. Black
• Ceramics Tube Cable Entry:
For the ceramics tube which is also a wetted
part, read “Lining” in “Wetted part”. JIS G1/2 female
Coating: ASME 1/2 NPT female
General-purpose, and Explosion Protection (Integral ISO M20 x 1.5 female
Flowmeter, Remote Sensor and Transmitter): Cable Entry Direction:
Standard Coating: For Integral Flowmeter and Remote Sensor, the
cable entry direction can be specified from +90,
Coated Part Coating Specification +180, or -90 degree rotation when optional code
Sensor housing RH is ordering, and also can be changed by
Polyurethane resin solvent
Sensor flanges coating, or no coating (*1) customer after delivery. However, it can not be
(for flange type) changed after delivery when submersible-use or
Sensor terminal box optional code DHC (district heating and cooling /
(for remote type, condensation proof use) is selected.
incl. cover) Polyester resin powder
coating Wiring Terminal:
Transmitter housing
(incl. cover) Intra-system Connection Part (*1):
M4 Screw type
Extra-system Connection Part (*2):
Rugged Coating (*2): M4 Screw or Clamp type
Coated Part Coating Specification *1: Connections between Remote Sensor and Remote
Transmitter for flow signal and excitation current.
Sensor housing Expoxy and polyurethane *2: Connections at Integral Flowmeter and Remote
Sensor flanges resin solvent coating, or no Transmitter for input/output signals and power supply.
(for flange type) coating (*1)
Mounting:
Sensor terminal box
(for remote type, Remote Transmitter: 2-inch pipe mounting
incl. cover) Epoxy and polyurethane resin
solvent coating Grounding:
Transmitter housing Grounding Resistance: 10 Ω or less
(incl. cover) Note: When the built-in lightning protector as standard is not
required, grounding resistance 100 Ω or less can be
applied.
For grounding of explosion protection, appropriate
construction is required according to the regulations of
each country.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
6
n FUNCTIONS PROFIBUS PA
Note: For AXG1A remote transmitter, read general specifications Flow rate (%), Flow velocity, Volume flow
(GS 01E22C01-01EN). rate, Mass flow rate, Calorie, Totalizer 1,
For AXFA11G remote transmitter, read general Totalizer 2, Totalizer 3, Adhesion level, Flow
specifications (GS 01E20C01-01E). noise level, Tag number, Communication
Display and Setting: protocol, Total 1 count, Total 2 count, Total 3
Display unit (3 infrared switches with LCD) enables count, AI1.OUT, AI2.OUT, TOT1.OUT, TOT2.
the user to set the parameters without opening the OUT, TOT3.OUT
display cover. Online Trend Screen:
Note: Parameter setting by setting tool such as HHT Display one data as trend graph. The display
(handheld terminal) and FieldMate (device adjustment / data can be changed with infrared switches or
management software) is also possible. automatic scroll function (scroll period 2, 4, or
Display: 8 seconds) selecting up to four data.
Full dot matrix LCD, 64 × 128 dots, with backlight, Selectable Data in Online Trend Screen:
dot reversal display available Flow rate (%), Flow velocity, Volume flow rate,
Display Language (*): Mass flow rate, Calorie, Totalizer 1, Totalizer 2,
Display Code 1: Totalizer 3, Current output 1, Current output 2
English, French, German, Italian, Spanish, Note: Calorie is available for Input/Output signal type H, J,
Portuguese, Russian and Japanese. The display or K.
languages are selectable and can be changed by Current output 2 is available for Input/Output type
B, C, or H.
customer.
Totalizer 3, Current output 1 and Current output
Display Code 2: 2 are not available for FOUNDATION Fieldbus or
English and Chinese. The display languages are PROFIBUS PA.
selectable and can be changed by customer. Alarm Screen:
Display Code 3: When an alarm occurs, the flow rate screen and
English. the alarm screen are alternately displayed in the
* : The setting is English when shipped from factory.
cycle (2, 4, or 8 seconds) linked with the flow
Display Screen Configuration: rate screen update cycle. Select simple screen
Display Screen Item: (single line display) or detail screen (with alarm
Status display (icon), Time (necessary to set the countermeasure display).
time at power-on), Data display (max. four lines), NAMUR NE 107 Alarm Display Function:
Infrared switch operation status Based on NAMUR NE 107, alarms are classified
Flow Rate Screen: and displayed as follows. It can also be set to hide.
Measured Data Screen or Online Trend Screen F: Failure
is available. Update period selectable from 0.2, C: Function Check
0.4, 1, 2, 4, and 8 seconds. S: Out of Specification
Measured Data Screen: M: Maintenance Required
Display up to 4 data points simultaneously Offline Trend Screen (when optional code MC
with numbers, bar graphs, icons, or character (microSD card) is selected):
strings. Specify up to 8 points of data and Data stored by the data logging function can be
change display data with infrared switches or displayed on the trend screen. The selectable data
automatic scroll function (scroll period 2, 4, or is the same as that for the Online Trend Screen.
8 seconds). Display Backlight Flashing (Squawk) Function:
Selectable Data in Measured Data Screen: Display backlight can be set to flash once or
BRAIN, HART, Modbus, EtherNet/IP continuously at 4-second cycle to identify the device.
Flow rate (%), Flow velocity, Volume flow Display Operation Authority:
rate, Mass flow rate, Calorie, Totalizer 1, Display operation authority level against the
Totalizer 2, Totalizer 3, Adhesion level, parameters can be controlled by selecting from
Current output 1, Current output 2, Flow operator, maintenance, or specialist by passcode.
noise level, Tag No., Communication Operator:
protocol, Totalizer 1 count, Totalizer 2 count, Only parameters related to display setting can
Totalizer 3 count, Modbus info be set.
Note: Calorie is available for Input/Output signal type
H, J, or K.
Maintenance:
Current output 2 is available for Input/Output Only parameters related to display setting and
signal type B, C, or H. zero adjustment can be set.
Modbus info is available for Modbus Specialist:
communication type. All parameters can be set.
FOUNDATION Fieldbus
Flow rate (%), Flow velocity, Volume flow
rate, Mass flow rate, Calorie, Totalizer 1,
Totalizer 2, Adhesion level, Flow noise level,
PDtag, Communication protocol, Total 1
count, Total 2 count, AI1 Flow rate, AI1 Flow
rate (%), AI1.OUT, AI2.OUT, AI3.OUT, AI4.
OUT, IT1.OUT, IT2.OUT, AR.OUT

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
7
Communication Function: FOUNDATION Fieldbus:
BRAIN: Output Signal:
Communication Signal: Fieldbus communication signal conforming to
Superimposed on the Current Output 1 the standard specifications (H1) of FOUNDATION
Communication Line Condition: Fieldbus.
Load Resistance: Communication Requirements:
250 to 450 Ω (including cable resistance) Supply Voltage: 9 to 32 V DC
Load Capacitance: 0.22 μF or less Current Draw: 15 mA (maximum)
Load Inductance: 3.3 mH or less For details, please refer IM 01E21A02-03EN.
Input Impedance of Communicating Device: Note: I/O2 (Pulse/Status Output1) is intended only for the
10 kΩ or more (at 2.4 kHz) calibration use.
Communication Distance: PROFIBUS PA:
Up to 1.5 km (0.93 miles), when polyethylene Output Signal:
insulated PVC-sheathed cables (CEV cables) Fieldbus communication signal conforming to the
are used. Communication distance varies standard specifications of PROFIBUS PA.
depending on the type of cable and wiring used. Communication Requirements:
Distance from Power Line: Supply Voltage: 9 to 32 V DC
15 cm (6 in.) or more. (Parallel wiring should Current Draw: 15 mA (maximum)
be avoided) For details, please refer IM 01E21A02-04EN.
HART: Note: I/O2 (Pulse/Status Output1) is intended only for the
calibration use.
Protocol Version: HART 7
Communication Signal: EtherNet/IP:
Superimposed on the Current Output 1 Output:
Communication Line Condition: Digital communication signal based on CIP
Load Resistance: (Common Industrial Protocol), adaptor.
230 to 600 Ω (including cable resistance) Physical layer:
Modbus: 10BASE-T / 100BASE-TX
Communication protocol: Transmission speed:
2-wire half duplex RS-485 Modbus 10 / 100 Mbps with auto negotiation
Flow control: None Functional Specifications:
Baud rate [bps]: 1200, 2400, 4800, 9600, 19200*, - Device Level Ring (DLR)
38400, 57600, 115200 - Cyclic data communication for flow, total and
Start bit: 1 bit (Fixed) diagnostics
Stop bit: 1 bit*, 2 bits - Explicit message communication for flow, total,
Parity bit: Odd, Even*, None diagnostics and write protect
Transfer mode: - Number of simultaneous connections (Explicit
RTU (Remote Terminal Unit) message): Maximum 6
ASCII - Number of simultaneous connections (Cyclic):
Data length: 8 bits Maximum 4
LSB (Least Significant Bit sent first) Displayed Language:
Slave address: 1* to 247 English
Support function: See IM 01E21A02-05EN Ethernet communication:
(Modbus communication type). - Maximum segment length: 100 m
Bus termination: - Web server: Real time monitoring,
Standard RS-485 bus termination configuration change and operation for
ON (bus end), OFF* (not bus end) ADMAG TI is available from web browser
*: Factory default setting - DHCP client functionality
Modbus cable For details, please refer IM 01E21A02-06EN.
3-Wire cable (twisted pair (D0, D1) and Note: No Pulse/Status Output is available.
Common) with shield should be used. Wire
gauge should be AWG24 or wider.
The characteristic impedance of the cable higher
than 100ohm may be preferred.
Line Termination
Modbus cable requires Line Termination at
each of the two ends of the bus to minimize the
reflections. For details, please refer to "Modbus
over serial line specification and implementation
guide V1.02".

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
8
Input/Output Function:
Input/Output Signal:
Input/Output up to four points can be selected from type A to K, P to T, 0, 2, 4, 6, F0, G0, P0 in the table.
Input/Output (HART, BRAIN)
Communication
Input/Output Signal
Type and I/O Code
I/O1 Terminal I/O2 Terminal I/O3 Terminal I/O4 Terminal BRAIN HART 7
Type A ― ― DA JA
Pulse/Status Output 2 Current Output 2
Type B DB JB
Passive Active
Status Input Current Output 2
Type C DC JC
(No-voltage) Active
Status Output Pulse/Status Output 2
Type D DD JD
Passive Passive
Status Input Pulse/Status Output 2
Type E DE JE
(No-voltage) Passive
Current Output 1 Pulse/Status Output 1
Active Passive Status Input Pulse/Status Output 2
Type F DF JF
(No-voltage) Active (with internal resistor)
Status Input Pulse/Status Output 2
Type G DG JG
(No-voltage) Active (without internal resistor)
Current Output 2 Current Input
Type H DH JH
Passive Active
Pulse/Status Output 2 Current Input
Type J DJ JJ
Passive Active
Status Input Current Input
Type K DK JK
(No-voltage) Active

Communication
Input/Output Signal
Type and I/O Code
I/O1 Terminal I/O2 Terminal I/O3 Terminal I/O4 Terminal BRAIN HART 7
Type P ― DP JP
Pulse/Status Output 1
Passive Pulse/Status Output 2
Type Q DQ JQ
Current Output 2 Passive
Type R Current Output 1 Passive ― DR JR
Passive Pulse/Status Output 1
Passive (NAMUR) Pulse/Status Output 2
Type S DS JS
Passive (NAMUR)
Pulse/Status Output 1
Type T ― ― DT JT
Passive
Note: "Active" means no external power supply, "Passive" means external power supply is required.
Input/Output (Modbus)
Input/Output Signal
Communication
Type I/O3 Terminal I/O4 Terminal
I/O1 Terminal I/O2 Terminal and I/O Code
I/O3+ I/O3- I/O4+ I/O4-
Type 0 ― M0
Current Input
Type 2 Pulse/Status Output 1 Modbus Modbus Modbus M2
Active ―
Passive C(Common) B(D1) A(D0)
Current Output 2
Type 6 M6
Active
Note: "Active" means no external power supply, "Passive" means external power supply is required.
Input/Output (FOUNDATION Fieldbus)
Input/Output Signal Communication
Type
I/O1 Terminal I/O2 Terminal I/O3 Terminal I/O4 Terminal and I/O code
Pulse/Status Output 1
Fieldbus
Type F0 Passive ― ― F0
Passive
* Intended only for the calibration use
Input/Output (PROFIBUS PA)
Input/Output Signal Communication
Type
I/O1 Terminal I/O2 Terminal I/O3 Terminal I/O4 Terminal and I/O code
Pulse/Status Output
Fieldbus
Type G0 Passive ― ― G0
Passive
* Intended only for the calibration use
Input/Output (EtherNet/IP)
Input/Output Signal Communication
Type
PORT1 PORT2 and I/O code
Type P0 EtherNet/IP EtherNet/IP P0

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
9
Input Signal • Digital communication (RS485 Modbus
• Current Input (Active) (Type H, J, K, 2) protocol) (Type 0, 2, 6)
4 to 20 mA DC temperature signal from two-wire 2-wire half duplex RS-485 Modbus
type transmitter. • Digital communication (FOUNDATION Fieldbus)
Internal Power Supply: 24 V DC ±20 %, (Type F0)
Current Range: 2.4 to 21.6 mA Fieldbus communication signal conforming to
• Status Input (Dry contact) (Type C, E, F, G, K) the standard specifications (H1) of FOUNDATION
Load Resistance: Fieldbus.
200 Ω or less (ON), 100 kΩ or more (OFF) • Digital communication (PROFIBUS PA)
(Type G0)
Output Signal Fieldbus communication signal conforming to the
• Current Output (Active) (Type A to K, 6) standard specifications of PROFIBUS PA.
4 to 20 mA DC signal • Digital communication (EtherNet/IP)
Load Resistance: (Type P0)
750 Ω maximum, including cable resistance Refer to GS 01E21F02-02EN.
• Current Output (Passive) (Type H) Temperature Input Processing Function:
4 to 20 mA DC signal Input current signal as temperature difference or
External Power Supply: 10.5 to 32 V DC absolute temperature. It can be used for temperature
Load Resistance: check by parameter, mass flow calculation by density
911 Ω maximum, including cable resistance correction, and calorie calculation.
• Current Output (Passive) (Type P to T)
4 to 20 mA DC signal Flow Calculation Function:
External Power Supply: 10.5 to 30 V DC Excitation Method:
Load Resistance: - Dual Frequency Excitation for sizes 2.5 to 400 mm
826 Ω maximum, including cable resistance (0.1 to 16 in.)
• Pulse/Status Output (Passive) (Type A to K, P, - Pulsed DC Excitation for size 500 mm (20 in.)
Q, T, 0, 2, 6, F0, G0) Enhanced Dual Frequency Excitation for sizes 25
Transistor contact output (open collector) to 200 mm (1 to 8 in.). Optional code HF2.
Contact Capacity: 30 V DC (OFF), 200 mA (ON) Span Setting:
Pulse Rate: Span flow can be set in units such as volume flow
0.0001 to 10000 pps (pulse per second) rate, mass flow rate, time, and flow rate value. The
Pulse Width: velocity unit can also be set.
0.05, 0.1, 0.5, 1, 20, 33, 50, 100, 200, 330, 500, Volume Flow Rate Unit:
1000, 2000 ms, or Duty cycle 50% (Maximum kcf, cf, mcf, Mgal (US), kgal (US), gal (US), mgal
pulse width 5 minutes) configurable (US), kbbl (US)*, bbl (US)*, mbbl (US)*, μbbl
Frequency Output Range: 1 to 12500 Hz (US)*, Ml (megaliter), m3, kl (kiloliter), l (liter), cm3
*: "US Oil" or "US Beer" can be selected.
• Pulse/Status Output (Passive) NAMUR (Type R, S)
Mass Flow Rate Unit:
Refer to EN 60947-5-6.
klb (US), lb (US), t (ton), kg, g
• Pulse/Status Output (Active)
Calorie Unit:
Without Internal Resistor (Type G)
MJ, kJ, J, kcal, cal, BTU (Specific heat setting
• Driving Electronic Counter
and temperature input required)
Load Resistance: 1 kΩ or more,
Velocity Unit: ft, m (meter)
Internal Power Supply: 24 V DC ±20 %
Time Unit: s (second), min (minute), h (hour), d (day)
Pulse Rate:
Mass Flow Rate Processing:
0.0001 to 10000 pps (pulse per second)
The mass flow rate Vm is obtained in the following
Pulse Width:
expression.
0.05, 0.1, 0.5, 1, 20, 33, 50, 100, 200, 330,
Vm= Vf×ρ
500, 1000, 2000 ms, or Duty cycle 50%
Vm: Mass flow rate [kg/s]
(Maximum pulse width 5 minutes) configurable
Vf: Volume flow rate [m3/s]
Frequency Output Range: 1 to 12500 Hz
ρ: Density [kg/m3]
• Driving Electromechanical Counter
Calorie Processing:
Maximum Current: 150 mA,
The calorie Q is obtained in the following
Internal Power Supply: 24 VDC ±20 %
expression.
Pulse Rate: 0.0001 to 2 pps (pulse per second)
Q = c×Vm×Δt
Pulse Width: 20, 33, 50, or 100 ms configurable
Q: Calorie [J/s]
With Internal Resistor (Type F)
C: Specific heat [J/kg•K]
Internal resistor: 2.2 kΩ,
Vm: Mass flow rate [kg/s]
Internal Power Supply: 24 VDC ±20 %
ΔT: Temperature difference [K]
Pulse Rate:
0.0001 to 10000 pps (pulse per second)
Pulse Width:
0.05, 0.1, 0.5, 1, 20, 33, 50, 100, 200, 330,
500, 1000, 2000 ms, or Duty cycle 50%
(Maximum pulse width 5 minutes) configurable

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
10
Damping Function (63% response): Absolute Range:
Can be set for each measurement value of flow With 12 mA as flow rate zero, measurements in the
velocity, volume flow rate, mass flow rate, calorie, forward (12 to 20 mA) and reverse (4 to 12 mA)
flow noise. directions are possible in a single range.
Output Damping: Totalization Switch:
For each measured value, the time constant Status signal is output when the totalized value
for instantaneous value output (0.1 to 200.0 becomes equal to or larger than the set value.
seconds, shipped with 3.0 seconds) and the time Preset Totalization:
constant for totalization / pulse output (0.0 to By parameter setting or status input, the totalized
200.0 seconds, shipped with 3.0 seconds) can value is preset to zero or a set value.
be individually set. In the case of piston pump 0% Signal Lock:
etc., it is possible to measure pulsatile flow up to With status input, the current output is forcibly fixed
1 Hz with output damping 0.1 seconds. However, to 0%. Mode is selectable whether to continue
note that decreasing damping time generally output processing for instantaneous flow rate
increases output fluctuation. display/ pulse output/ flow rate totalization or to fix
Display Damping: flow rate at 0.
A common time constant can be set for each Alarm Function:
screen display value of each measurement Alarm Configuration:
value. Time constant 0.0 to 200.0 seconds Alarms are classified into system alarm (device
(shipped with 0.0 seconds). failure), process alarm, setting alarm, and warning.
Current Output: Alarm output availability can be selected for each item.
Current signal (4 to 20 mA DC) proportional to Current Output at Alarm Occurrence:
instantaneous flow rate is output. The current output at alarm occurrence is arbitrarily
Pulse Output: selected from 2.4 mA or less, 3.8 mA fixed, 4 mA
The totalized value of the flow rate is converted fixed, 20.5 mA fixed, 21.6 mA or more, measured
into the number of pulses converted by the pulse value, or HOLD.
rate, and is output. Alarm Countermeasure Indication:
Frequency Output: A specific countermeasure method can be
Frequency signal (Duty 50%) proportional to the displayed on the display when an alarm occurs.
instantaneous value of the flow rate is output. Alarm Type:
Output terminal is shared with pulse output. System Alarm:
Totalization Function: CPU failure, A/D converter failure, Sensor coil
Three independent totalizers can be allocated circuit break (open), Sensor coil short circuit
independently, including the start and stop of Process Alarm:
integration, for each measured value of volume Input signal error (signal overflow), Sensor empty
flow rate, mass flow rate, and calorie. pipe, Electrode adhesion (of insulator)
Totalization Type: Setting Alarm:
Forward / reverse difference flow totalization, Detect inconsistency in parameter setting
Absolute value totalization, Forward direction Warning:
totalization, Reverse direction totalization Warning in a state where measurement can be
Totalization Display: continued
Select from actual flow rate display or count Alarm History: Keep history of up to four alarms.
value display scaled by counter conversion rate.
Low-cut Function: Verification Function:
For each current output, pulse output, or frequency Function to diagnose the soundness of the device
output, the output signal below the set actual flow itself. Diagnose the magnetic circuit, excitation
rate can be cut. (*). It is independent for current circuit, arithmetic processing circuit, etc. offline (i.e.
output, common for pulse output and frequency flow measurement function stopped) and display the
output. result without demounting the device from piping.
*: When "Forward and Reverse Flow Measurement" or Data Management Function:
"Absolute Range" is used, the output signal below the set Store / Restore Function of Parameters:
actual flow rate value against the absolute value of the Main parameters can be stored and restored using
measured one is cut. nonvolatile memory of display unit. The restore can
Output Processing Function: also be used for copying parameters to another
Multi-range: device (except for parameters under unmatched
Flow range can be switched to two ranges by specification for the devices). When optional code
status input or automatic switching. By status MC is selected, this function is also available by
output, it is possible to identify in what range the using microSD card.
measurement is being measured, and the status is
also displayed on the display.
Forward and Reverse Flow Measurement:
Flow rate measurement in both forward and
reverse directions is possible. By status output,
it is possible to identify in which direction the
measurement is being performed, and the status is
also displayed on the display.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
11
Data Logging Function (when optional code MC EMC:
(microSD card) is selected): EN61326-1 Class A, Table 2
It is possible to log up to four process data at the EN61326-2-3
same time. In addition to displaying the logged EN61326-2-5
results on the trend screen, it is also possible to (only for AXG integral type flow meter and AXG4A
connect the microSD card to a PC and retrieve the transmitter combined with AXG sensor)
data. EN61000-3-2 Class A
Logging Cycle: EN61000-3-3
1 second, 10 seconds, 30 seconds, 1 minute, 5 CE marking (optional code EC):
minutes, 30 minutes, 1 hour CE marking is attached to non-Explosion protected
Logging Time: type, ATEX Explosion protected type and IECEx
10 minutes, 30 minutes, 1 hour, 3 hours, 12 Exprosion protected type.
hours, 24 hours, 72 hours, 240 hours, 720 hours, The product which is attaching CE marking is in
1440 hours conformity with the statutory requirements of the
Logging Data: applicable EU Directives.
Flow velocity, Volume flow rate, Mass flow
rate, Calorie, Flow noise, Adhesion resistance, EU RoHS Directive:
Note: Only applicable when optional code EC (CE marking)
Electrode potential (A, B), Flow signal peak value is selected.
Data Security During Power Failure:
Protection of data, such as parameters and Sanitary Standard:
integrated values, by nonvolatile memory at power 3-A Sanitary Certification* (optional code 3A)
*: Only for process connection code HAB (Tri-Clamp)
failure.
Factory Default Parameter Restore:
It is possible to restore the parameters to the values Morocco conformity mark :
that were set at the time of factory shipment. This conformity mark indicates that the product
Lightning Protection: complies with Moroccan safety and EMC requirements.
Note: Applicable for AXG002 to 500. Except INMETRO
Built-in lightning protector for excitation(*), signal explosion ptrotection type, code UF2.
common(*), input/output terminals, and power supply
terminal. Functional safety standard:
Test Standard: IEC61000-4-5 IEC 61508 (Parts 1 - 7: 2010; compliant with
Test Method: Functional Safety of Electrical/Electronic/
Series mode 1 kV / Common mode 2 kV Programmable Electronic Safety-related Systems)
Surge waveform 8/20 μS This product can be used in safety instrumented
*: Integral Flowmeter is excluded. systems up to SIL2 in simplex configuration and SIL3
in redundant configuration.
For details, please refer to IM01E21A21-02EN
n CONFORMITY STANDARDS (ADMAG TI Series AXG/AXW Magnetic Flowmeter
If exporting the product, it must be fully complied with Safety Manual).
all applicable laws and regulations.
Safety Requirements:
EN61010-1
EN61010-2-030
CAN/CSA-C22.2 No.61010-1
CAN/CSA-C22.2 No.61010-2-30
CAN/CSA-C22.2 No.94.2
UL 61010-1
UL 61010-2-030
UL 50E
IEC 60529
Altitude at Installation Site:
Max. 2000 m above sea level
Installation Category (Overvoltage category): II
Micro Pollution Degree: 2
Macro Pollution Degree: 4
Protection Degree:
General-purpose: IP66/IP67, Type 4X (CSA)
Submersible: IP68*
Explosion Protection: Read "Explosion Protection".
Hygienic: IP66/IP67, Type 4X (CSA)
Hygienic with Explosion Protection: Read
"Explosion Protection".
* Conforming to continuous dive under the test conditions
as follows;
1 month with fresh water and 50 m under the water
surface (hydraulic pressure 0.5 MPa). However, adverse
conditions such as sewage and seawater are excluded.
Protect the cable by appropriate means, such as
protected separately with conduit piping.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
12
PED (Pressure Equipment Directive):
Note: Applicable only when optional code EC (CE marking) is selected.
• Technical Data
Module: H
Type of Equipment: Piping
Type of Fluid: Liquid and Gas
Group of Fluid*4: 1 and 2

• General-purpose, Submersible, and Explosion Protection

PROCESS DN*1 PS*1 PS•DN


MODEL CATEGORY*2, *4
CONNECTION (mm) (bar) (MPa) (bar•mm) (MPa•mm)
AXG002 Wafer, Flange 2.5 40 4 100 10 Sound Engineering Practice (SEP)*3
AXG005 Wafer, Flange 5 40 4 200 20 Sound Engineering Practice (SEP)*3
AXG010 Wafer, Flange 10 40 4 400 40 Sound Engineering Practice (SEP)*3
AXG015 Wafer, Flange 15 40 4 600 60 Sound Engineering Practice (SEP)*3
AXG025 Wafer, Flange 25 40 4 1000 100 Sound Engineering Practice (SEP)*3
AXG032 Wafer, Flange 32 40 4 1280 128 II
AXG040 Wafer, Flange 40 40 4 1600 160 II
AXG050 Wafer, Flange 50 40 4 2000 200 II
AXG065 Wafer, Flange 65 40 4 2600 260 II
AXG080 Wafer, Flange 80 40 4 3200 320 II
AXG100 Wafer, Flange 100 40 4 4000 400 III
Wafer 125 20 2 2500 250 II
AXG125
Flange 125 40 4 5000 500 III
Wafer 150 20 2 3000 300 II
AXG150
Flange 150 40 4 6000 600 III
Wafer 200 20 2 4000 400 III
AXG200
Flange 200 40 4 8000 800 III
AXG250 Flange 250 20 2 5000 500 III
AXG300 Flange 300 20 2 6000 600 III
AXG350 Flange 350 18 1.8 6300 630 III
AXG400 Flange 400 16 1.6 6400 640 III

• Hygienic, and Hygienic Explosion Protection

DN*1 PS*1 PS•DN


MODEL CATEGORY*2, *4
(mm) (bar) (MPa) (bar•mm) (MPa•mm)
AXG015 15 10 1 150 15 Sound Engineering Practice (SEP)*3
AXG025 25 10 1 250 25 Sound Engineering Practice (SEP)*3
AXG032 32 10 1 320 32 I
AXG040 40 10 1 400 40 I
AXG050 50 10 1 500 50 I
AXG065 65 10 1 650 65 I
AXG080 80 10 1 800 80 I
AXG100 100 10 1 1000 100 I
AXG125 125 10 1 1250 125 II
*1: PS: Maximum allowable pressure for Pipe
PS indicates the allowable pressure for pipe of the Magnetic flowmeter at PED certification, and is different from the maximum
working pressure as the Magnetic flowmeter.
DN: Nominal size
*2: For details, refer to “Table 6 covered by ANNEX II of Directive 2014/68/EU”.
*3: Article 4, paragraph 3 of Directive 2014/68/EU
*4: Models classified in categories I or II shall not be used for unstable gases of Group 1.

CRN (Canadian Registration Number):


Note: Applicable only when optional code CS (Canada domestic sales) is selected.
CRN is a registration number for pressure equipment, required to use it in each Canadian province or territory.
Integral flowmeter and Remote sensor (for size 2.5 to 400 mm) are registered by all provinces and territories in
Canada.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
13
n HAZARDOUS AREA CLASSIFICATION Process Temperature:
Select appropriate equipment in accordance with See Table(a) and Table(b)
the laws and regulations of the relevant country/ Power Supply:
region, when it is used in a location where explosive 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
atmospheres may be present. 24 Va.c. (50/60 Hz) / 24 Vd.c.
Electrical parameters:
ATEX Terminals: L/+, N/-
Applicable Standard: Um: 250 V
EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, Terminals: Iout1(+, -), Iout2(+, -)
EN 60079-11, EN 60079-31 Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Certificate:FM 17ATEX0031X Terminals: P/Sout1(+, -), P/Sout2(+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
(Integral Flowmeter)
Flameproof (Explosion Protection Code: KF2) Flameproof with Intrinsically Safe output for
FOUNDATION Fieldbus / PROFIBUS PA
Type of Gas Atmosphere Protection
(Explosion Protection Code: KT2)
Group: II
Category: 2G Type of Gas Atmosphere Protection:
Type of Protection: Group: II
Ex db eb ia IIC T6...T3 Gb Category: 2(1)G
(Transmitter Wiring Terminal: M4 screw type) Type of Protection:
Ex db eb ia IIC T6...T3 Gb Ex db eb ia [ia Ga] IIC T6...T3 Gb
Terminal Compartment: Ex db or Ex eb Terminal Compartment: Ex db or Ex eb
(Transmitter Wiring Terminal: Clamp type) (Transmitter Wiring Terminal: Clamp type)
Type of Dust Atmosphere Protection Type of Dust Atmosphere Protection
Group: II Group: II
Category: 2D Category: 2(1)D
Type of Protection: Type of Protection:
Ex tb IIIC T75°C...T130°C Db Ex tb [ia Da] IIIC T75°C...T130°C Db

Enclosure: IP66/IP67 in accordance with EN 60529 Enclosure: IP66/IP67 in accordance with EN 60529
Maximum Surface Temperature: Maximum Surface Temperature:
See Table(a) and Table(b) See Table(a) and Table(b)
Ambient Temperature: Ambient Temperature:
See Table(a) and Table(b) See Table(a) and Table(b)
Process Temperature: Process Temperature:
See Table(a) and Table(b) See Table(a) and Table(b)
Power Supply: Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c. 24 Va.c. (50/60 Hz) / 24 Vd.c.
Um: 250 V Electrical parameters:
Current I/O: 4 to 20 mA, 32 Vd.c. max. Terminals: L/+, N/-
Digital I/O: 30 Vd.c. max., 200 mA max. Um: 250 V
Fieldbus I/O: 32 Vd.c max., 15 mA max. Terminals: Fieldbus (+, -)
Modbus I/O: 5 Vd.c. typ. FISCO field device or
Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Terminals: P/Sout1 (+, -)
Flameproof with Intrinsically Safe output
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
(Explosion Protection Code: KJ2)
Type of Gas Atmosphere Protection:
(Remote Sensor)
Group: II
Category: 2(1)G Flameproof (Explosion Protection Code: KF2)
Type of Protection: Type of Gas Atmosphere Protection
Ex db eb ia [ia Ga] IIC T6...T3 Gb Group: II
Terminal Compartment: Ex db or Ex eb Category: 2G
(Transmitter Wiring Terminal: Clamp type) Type of Protection:
Type of Dust Atmosphere Protection Ex db eb ia IIC T6…T3 Gb
Group: II Type of Dust Atmosphere Protection
Category: 2(1)D Group: II
Type of Protection: Category: 2D
Ex tb [ia Da] IIIC T75°C...T130°C Db Type of Protection:
Ex tb IIIC T75°C...T150°C Db
Enclosure: IP66/IP67 in accordance with EN 60529
Maximum Surface Temperature: Enclosure: IP66/IP67 in accordance with EN 60529
See Table(a) and Table(b) Maximum Surface Temperature:
Ambient Temperature: See Table(a) and Table(b)
See Table(a) and Table(b) Ambient Temperature:
See Table(a) and Table(b)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
14
Process Temperature: Flameproof with Intrinsically Safe output for
See Table(a) and Table(b) FOUNDATION Fieldbus / PROFIBUS PA
Um: 250 V (Explosion Protection Code: KT2)
Type of Gas Atmosphere Protection
(Remote Transmitter) Group: II
Flameproof (Explosion Protection Code: KF2) Category: 2(1)G
Type of Protection:
Type of Gas Atmosphere Protection Ex db [ia Ga] IIC T6...T3 Gb or
Group: II Ex db eb [ia Ga] IIC T6...T3 Gb
Category: 2G (Transmitter Wiring Terminal: Clamp type)
Type of Protection:
Ex db IIC T6 Gb Type of Dust Atmosphere Protection
(Transmitter Wiring Terminal: M4 screw type) Group: II
Ex db IIC T6 Gb or Ex db eb IIC T6 Gb Category: 2(1)D
(Transmitter Wiring Terminal: Clamp type) Type of Protection:
Ex tb [ia Da] IIIC T75°C Db
Type of Dust Atmosphere Protection
Group: II Enclosure: IP66/IP67 in accordance with EN 60529
Category: 2D Maximum Surface Temperature: T75°C
Type of Protection: Ambient Temperature: –40°C to +60°C
Ex tb IIIC T75°C Db Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Enclosure: IP66/IP67 in accordance with EN 60529 24 Va.c. (50/60 Hz) / 24 Vd.c.
Maximum Surface Temperature: T75°C Electrical parameters:
Ambient Temperature: –40°C to +60°C Terminals: L/+, N/-
Power Supply: Um: 250 V
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Terminals: Fieldbus (+, -)
24 Va.c. (50/60 Hz) / 24 Vd.c. FISCO field device or
Current I/O: 4 to 20 mA, 32 Vd.c. max. Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Digital I/O: 30 Vd.c. max., 200 mA max. Terminals: P/Sout1 (+, -)
Fieldbus I/O: 32 Vd.c max., 15 mA max. Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Modbus I/O: 5 Vd.c. typ.

Flameproof with Intrinsically Safe output


(Explosion Protection Code: KJ2)
Type of Gas Atmosphere Protection
Group: II
Category: 2(1)G
Type of Protection:
Ex db [ia Ga] IIC T6...T3 Gb or
Ex db eb [ia Ga] IIC T6...T3 Gb
(Transmitter Wiring Terminal: Clamp type)
Type of Dust Atmosphere Protection
Group: II
Category: 2(1)D
Type of Protection:
Ex tb [ia Da] IIIC T75°C Db

Enclosure: IP66/IP67 in accordance with EN 60529


Maximum Surface Temperature: T75°C
Ambient Temperature: –40°C to +60°C
Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Electrical parameters:
Terminals: L/+, N/-
Um: 250 V
Terminals: Iout1(+, -), Iout2(+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Terminals: P/Sout1(+, -), P/Sout2(+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
15
Table (a): Temperature Table (ATEX)

Temperature Table*
Process Integral
Model Size Lining Remote
Connection
Flowmeter Sensor
AXG002, AXG005, 2.5 to 15 mm
Wafer, Flange PFA Lining Table A Table C
AXG010, AXG015 (0.1 to 0.5 in.)
AXG025, AXG032,
AXG040, AXG050, 25 to 125 mm
Wafer, Flange PFA Lining Table B Table D
AXG065, AXG080, (1 to 5 in.)
AXG100, AXG125
AXG150, AXG200,
150 to 400 mm
AXG250, AXG300, Wafer, Flange PFA Lining Table A Table C
(6 to 16 in.)
AXG350, AXG400
AXG015, AXG025,
AXG032, AXG040,
15 to 125 mm Clamp, Union,
AXG050, AXG065, PFA Lining Table E Table F
(0.5 to 5 in.) Butt Weld Joint
AXG080, AXG100,
AXG125
AXG002, AXG005,
AXG010, AXG015,
AXG025, AXG040, 2.5 to 200 mm
Wafer Ceramics Tube Table G Table H
AXG050, AXG080, (0.1 to 8 in.)
AXG100, AXG150,
AXG200
*: For details, see Table No. on Table (b).

Table (b): Ambient Temperature and Process Temperature (ATEX)

Ambient Temperature Maximum Surface Process


Table No.
Temperature Class Temperature Temperature
T6 T75°C -40°C to +75°C
T5 T90°C -40°C to +90°C
A -40°C to +60°C
T4 T120°C -40°C to +120°C
T3 T130°C -40°C to +130°C
-40°C to +45°C T6 T75°C -40°C to +50°C
T5 T90°C -40°C to +75°C
B
-40°C to +60°C T4 T120°C -40°C to +120°C
T3 T130°C -40°C to +130°C
T6 T75°C -40°C to +75°C
T5 T90°C -40°C to +90°C
C -40°C to +60°C
T4 T120°C -40°C to +120°C
T3 T150°C -40°C to +150°C
-40°C to +45°C T6 T75°C -40°C to +50°C
T5 T90°C -40°C to +75°C
D
-40°C to +60°C T4 T120°C -40°C to +120°C
T3 T150°C -40°C to +150°C
-10°C to +45°C T6 T75°C -10°C to +50°C
T5 T90°C -10°C to +75°C
E
-10°C to +60°C T4 T120°C -10°C to +120°C
T3 T130°C -10°C to +130°C
-10°C to +45°C T6 T75°C -10°C to +50°C
T5 T90°C -10°C to +75°C
F
-10°C to +60°C T4 T120°C -10°C to +120°C
T3 T150°C -10°C to +150°C
T6 T75°C -10°C to +75°C
T5 T90°C -10°C to +90°C
G -10°C to +60°C
T4 T120°C -10°C to +120°C
T3 T130°C -10°C to +130°C
T6 T75°C -10°C to +75°C
T5 T90°C -10°C to +90°C
H -10°C to +60°C
T4 T120°C -10°C to +120°C
T3 T150°C -10°C to +150°C

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
16
IECEx Flameproof with Intrinsically Safe output for
Applicable Standard: FOUNDATION Fieldbus / PROFIBUS PA
IEC 60079-0, IEC 60079-1, IEC 60079-7, (Explosion Protection Code: ST2)
IEC 60079-11, IEC 60079-31 Type of Gas Atmosphere Protection
Certificate: IECEx FMG 17.0014X Ex db eb ia [ia Ga] IIC T6...T3 Gb
Terminal Compartment: Ex db or Ex eb
(Integral Flowmeter) (Transmitter Wiring Terminal: Clamp type)
Flameproof (Explosion Protection Code: SF2) Type of Dust Atmosphere Protection
Type of Gas Atmosphere Protection Ex tb [ia Da] IIIC T75°C...T130°C Db
Ex db eb ia IIC T6...T3 Gb
(Transmitter Wiring Terminal: M4 screw type) Enclosure: IP66/IP67 in accordance with IEC 60529
Ex db eb ia IIC T6...T3 Gb Maximum Surface Temperature:
Terminal Compartment: Ex db or Ex eb See Table(c) and Table(d).
(Transmitter Wiring Terminal: Clamp type) Ambient Temperature:
See Table(c) and Table(d).
Type of Dust Atmosphere Protection Process Temperature:
Ex tb IIIC T75°C...T130°C Db See Table(c) and Table(d).
Power Supply:
Enclosure: IP66/IP67 in accordance with IEC 60529 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Maximum Surface Temperature: 24 Va.c. (50/60 Hz) / 24 Vd.c.
See Table(c) and Table(d). Electrical parameters:
Ambient Temperature: Terminals: L/+, N/-
See Table(c) and Table(d). Um: 250 V
Process Temperature: Terminals: Fieldbus (+, -)
See Table(c) and Table(d). FISCO field device or
Power Supply: Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Terminals: P/Sout1 (+, -)
24 Va.c. (50/60 Hz) / 24 Vd.c. Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Um: 250 V
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max. (Remote Sensor)
Fieldbus I/O: 32 Vd.c max., 15 mA max. Flameproof (Explosion Protection Code: SF2)
Modbus I/O: 5 Vd.c. typ. Type of Gas Atmosphere Protection
Ex db eb ia IIC T6…T3 Gb
Flameproof with Intrinsically Safe output Type of Dust Atmosphere Protection
(Explosion Protection Code: SJ2) Ex tb IIIC T75°C...T150°C Db
Type of Gas Atmosphere Protection
Ex db eb ia [ia Ga] IIC T6...T3 Gb Enclosure: IP66/IP67 in accordance with IEC 60529
Terminal Compartment: Ex db or Ex eb Maximum Surface Temperature:
Type of Dust Atmosphere Protection See Table(c) and Table(d).
Ex tb [ia Da] IIIC T75°C...T130°C Db Ambient Temperature:
See Table(c) and Table(d).
Enclosure: IP66/IP67 in accordance with IEC 60529 Process Temperature:
Maximum Surface Temperature: See Table(c) and Table(d).
See Table(c) and Table(d). Um: 250 V
Ambient Temperature:
See Table(c) and Table(d). (Remote Transmitter)
Process Temperature: Flameproof (Explosion Protection Code: SF2)
See Table(c) and Table(d).
Power Supply: Type of Gas Atmosphere Protection
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Ex db IIC T6 Gb
24 Va.c. (50/60 Hz) / 24 Vd.c. (Transmitter Wiring Terminal: M4 screw type)
Electrical parameters: Ex db IIC T6 Gb or Ex db eb IIC T6 Gb
Terminals: L/+, N/- (Transmitter Wiring Terminal: Clamp type)
Um: 250 V Type of Dust Atmosphere Protection
Terminals: Iout1(+, -), Iout2(+, -) Ex tb IIIC T75°C Db
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Terminals: P/Sout1(+, -), P/Sout2(+, -) Enclosure: IP66/IP67 in accordance with IEC 60529
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH Maximum Surface Temperature: T75°C
Ambient Temperature: –40°C to +60°C
Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max.
Fieldbus I/O: 32 Vd.c max., 15 mA max.
Modbus I/O: 5 Vd.c. typ.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
17
Flameproof with Intrinsically Safe output FM (USA)
(Explosion Protection Code: SJ2) Applicable Standard:
Type of Gas Atmosphere Protection FM 3600, FM3610, FM3615, FM3616, FM3810,
Ex db [ia Ga] IIC T6...T3 Gb or ANSI/UL 50E, NEMA 250, ANSI/UL 60079-0,
Ex db eb [ia Ga] IIC T6...T3 Gb ANSI/UL 60079-7, ANSI/UL 60079-11,
ANSI/UL 60079-18, ANSI/UL 61010-1,
Type of Dust Atmosphere Protection ANSI/UL 61010-2-30
Ex tb [ia Da] IIIC T75°C Db Certificate:
FM17US0140X
Enclosure: IP66/IP67 in accordance with IEC 60529
Maximum Surface Temperature: T75°C (Integral Flowmeter)
Ambient Temperature: –40°C to +60°C
Power Supply: Flameproof (Explosion Protection Code: FF2)
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Type of Protection:
24 Va.c. (50/60 Hz) / 24 Vd.c. Explosionproof and Special protection for Class I,
Electrical parameters: Division 1, Groups A, B, C and D.
Terminals: L/+, N/- Dust-Ignitionproof for Class II,III, Division 1,
Um: 250 V Groups E, F and G.
Terminals: Iout1(+, -), Iout2(+, -) with Intrinsically Safe Electrodes for Class I,
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH Division 1, Groups A, B, C and D.
Terminals: P/Sout1(+, -), P/Sout2(+, -) Temperature Class T6…T3.
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Enclosure: Type 4X
Flameproof with Intrinsically Safe output for Ambient Temperature:
FOUNDATION Fieldbus / PROFIBUS PA See Table(c) and Table(d).
(Explosion Protection Code: ST2) Process Temperature:
See Table(c) and Table(d).
Type of Gas Atmosphere Protection Power Supply:
Ex db [ia Ga] IIC T6...T3 Gb or 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Ex db eb [ia Ga] IIC T6...T3 Gb 24 Va.c. (50/60 Hz) / 24 Vd.c.
(Transmitter Wiring Terminal: Clamp type) Um: 250 V
Type of Dust Atmosphere Protection Current I/O: 4 to 20 mA, 32 Vd.c. max.
Ex tb [ia Da] IIIC T75°C Db Digital I/O: 30 Vd.c. max., 200 mA max.
Fieldbus I/O: 32 Vd.c max., 15 mA max.
Enclosure: IP66/IP67 in accordance with IEC 60529 Modbus I/O: 5 Vd.c. typ.
Maximum Surface Temperature: T75°C
Ambient Temperature: –40°C to +60°C Flameproof with Intrinsically Safe output
Power Supply: (Explosion Protection Code: FJ2)
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c. Type of Protection:
Electrical parameters: Explosionproof and Special protection for Class I,
Terminals: L/+, N/- Division 1, Groups A, B, C and D.
Um: 250 V Dust-Ignitionproof for Class II,III, Division 1,
Terminals: Fieldbus (+, -) Groups E, F and G.
FISCO field device or with Intrinsically Safe Electrodes for Class I,
Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH Division 1, Groups A, B, C and D.
Terminals: P/Sout1 (+, -) Associated Apparatus for Class I,II,III, Division 1,
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH Groups A, B, C, D, E, F and G.
Temperature Class T6…T3.

Enclosure: Type 4X
Ambient Temperature:
See Table(c) and Table(d).
Process Temperature:
See Table(c) and Table(d).
Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Electrical parameters:
Terminals: L/+, N/-
Um: 250 V
Terminals: Iout1(+, -), Iout2(+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Terminals: P/Sout1(+, -), P/Sout2(+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
18
Flameproof with Intrinsically Safe output for Enclosure: Type 4X
FOUNDATION Fieldbus / PROFIBUS PA Ambient Temperature: -40°C to +60°C
(Explosion Protection Code: FT2) Power Supply:
Type of Protection: 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Explosionproof and Special protection for Class I, 24 Va.c. (50/60 Hz) / 24 Vd.c.
Division 1, Groups A, B, C and D. Current I/O: 4 to 20 mA, 32 Vd.c. max.
Dust-Ignitionproof for Class II,III, Division 1, Digital I/O: 30 Vd.c. max., 200 mA max.
Groups E, F and G. Fieldbus I/O: 32 Vd.c max., 15 mA max.
with Intrinsically Safe Electrodes for Class I, Modbus I/O: 5 Vd.c. typ.
Division 1, Groups A, B, C and D.
Associated Apparatus for Class I,II,III, Division 1, Flameproof with Intrinsically Safe output
Groups A, B, C, D, E, F and G. (Explosion Protection Code: FJ2)
Temperature Class T6…T3. Type of Protection:
Explosionproof for Class I, Division 1, Groups A, B,
Enclosure: Type 4X C and D.
Ambient Temperature: Dust-Ignitionproof for Class II,III, Division 1,
See Table(c) and Table(d). Groups E, F and G.
Process Temperature: Associated Apparatus for Class I,II,III, Division 1,
See Table(c) and Table(d). Groups A, B, C, D, E, F and G.
Power Supply: Temperature Class T6.
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c. Enclosure: Type 4X
Electrical parameters: Ambient Temperature: -40°C to +60°C
Terminals: L/+, N/- Power Supply:
Um: 250 V 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Terminals: Fieldbus (+, -) 24 Va.c. (50/60 Hz) / 24 Vd.c.
FISCO field device or Electrical parameters:
Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH Terminals: L/+, N/-
Terminals: P/Sout1 (+, -) Um: 250 V
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH Terminals: Iout1(+, -), Iout2(+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
(Remote Sensor) Terminals: P/Sout1(+, -), P/Sout2(+, -)
Flameproof (Explosion Protection Code: FF2) Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Type of Protection:
Explosionproof and Special Protection for Class I, Flameproof with Intrinsically Safe output for
Division 1, Groups A, B, C and D. FOUNDATION Fieldbus / PROFIBUS PA
Dust-Ignitionproof for Class II,III, Division 1, (Explosion Protection Code: FT2)
Groups E, F and G. Type of Protection:
with Intrinsically Safe Electrodes for Class I, Explosionproof for Class I, Division 1, Groups A, B,
Division 1, Groups A, B, C and D. C and D.
Temperature Class T6…T3. Dust-Ignitionproof for Class II,III, Division 1,
Groups E, F and G.
Enclosure: Type 4X Associated Apparatus for Class I,II,III, Division 1,
Ambient Temperature: Groups A, B, C, D, E, F and G.
See Table(c) and Table(d). Temperature Class T6.
Process Temperature:
See Table(c) and Table(d). Enclosure: Type 4X
Um: 250 V Ambient Temperature: -40°C to +60°C
Power Supply:
(Remote Transmitter) 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Flameproof (Explosion Protection Code: FF2) Electrical parameters:
Type of Protection: Terminals: L/+, N/-
Explosionproof for Class I, Division 1, Groups A, B, Um: 250 V
C and D. Terminals: Fieldbus (+, -)
Dust-Ignitionproof for Class II,III, Division 1, FISCO field device or
Groups E, F and G. Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Temperature Class T6. Terminals: P/Sout1 (+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
19
Japan Flameproof Korea
(Integral Flowmeter) Applicable Standard:
Applicable Standard: Notice of Ministry of Labor No. 2016-54
JNIOSH-TR-46-1 Harmonized with IEC 60079-0, IEC 60079-1, IEC
JNIOSH-TR-46-2 60079-7, IEC 60079-11
JNIOSH-TR-46-5 Certificate:
19-KA4BO-0020X (Integral flowmeter)
JNIOSH-TR-46-6
19-KA4BO-0022X (Remote Sensor)
JNIOSH-TR-46-9
19-KA4BO-0021X (Remote Transmitter)
Construction: Ex db eb ia IIC T4 Gb
Ex tb IIIC T120°C Db
Enclosure: IP66/IP67 (Integral Flowmeter)
Ambient Temperature: Type of Gas Atmosphere Protection
-40°C to +60°C (PFA Lining) Ex d e ia IIC T6...T3
-10°C to +60°C (Ceramics Tube)
Process Temperature: Enclosure: IP66/IP67 in accordance with IEC 60529
-40°C to +120°C (PFA Lining) Maximum Surface Temperature:
-10°C to +120°C (Ceramics Tube) See Table(c) and Table(d).
Maximum Surface Temperature: +120°C Ambient Temperature:
Power Supply: See Table(c) and Table(d).
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Process Temperature:
24 Va.c. (50/60 Hz) / 24 Vd.c. See Table(c) and Table(d).
Um=250 V Power Supply:
Current I/O: 4 to 20 mA, 32 Vd.c. max. 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Digital I/O: 30 Vd.c. max., 200 mA max. 24 Va.c. (50/60 Hz) / 24 Vd.c.
Excitation Circuit: 160 V max. Um: 250 V
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Power consumption: 13 W max.
Digital I/O: 30 Vd.c. max., 200 mA max.
(Remote Sensor) (Remote Sensor)
Applicable Standard:
JNIOSH-TR-46-1 Type of Gas Atmosphere Protection
JNIOSH-TR-46-2 Ex d e ia IIC T6...T3
JNIOSH-TR-46-5
JNIOSH-TR-46-6 Enclosure: IP66/IP67 in accordance with IEC 60529
JNIOSH-TR-46-9 Maximum Surface Temperature:
Construction: Ex db eb ia IIC T4 Gb See Table(c) and Table(d).
Ambient Temperature:
Ex tb IIIC T120°C Db
See Table(c) and Table(d).
Enclosure: IP66/IP67
Process Temperature:
Ambient Temperature: See Table(c) and Table(d).
-40°C to +60°C (PFA Lining) Um: 250 V
-10°C to +60°C (Ceramics Tube)
Process Temperature:
-40°C to +120°C (PFA Lining) (Remote Transmitter)
-10°C to +120°C (Ceramics Tube) Type of Gas Atmosphere Protection
Maximum Surface Temperature: +120°C Ex d IIC T6
Um=250 V
Excitation Circuit: 160 V max, 13 W max. Enclosure: IP66/IP67 in accordance with IEC 60529
Maximum Surface Temperature: T75°C
Ambient Temperature: –40°C to +60°C
(Remote Transmitter) Power Supply:
Applicable Standard: 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
JNIOSH-TR-46-1 24 Va.c. (50/60 Hz) / 24 Vd.c.
JNIOSH-TR-46-2 Current I/O: 4 to 20 mA, 32 Vd.c. max.
JNIOSH-TR-46-9 Digital I/O: 30 Vd.c. max., 200 mA max.
Construction: Ex db IIC T6 Gb
Ex tb IIIC T75°C Db
Enclosure: IP66/IP67
Ambient Temperature: -40°C to +60°C
Maximum Surface Temperature: +75°C
Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max.
Excitation Circuit: 160 V max.
Power consumption: 13 W max.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
20
INMETRO EAC
Applicable Standard: Applicable Standard:
ABNT NBR IEC 60079-0 ГОСТ 31610.0 (IEC 60079-0), ГОСТ IEC 60079-1,
ABNT NBR IEC 60079-1 ГОСТ Р МЭК 60079-7, ГОСТ 31610.11 (IEC
ABNT NBR IEC 60079-7 60079-11),
ABNT NBR IEC 60079-11 ГОСТ Р МЭК 60079-27, ГОСТ IEC 60079-31
ABNT NBR IEC 60079-31 Certificate: EAЭC RU C-JP.AA87.B.00388/20
Certificate: TÜV 18.3229 X
(Integral Flowmeter)
(Integral Flowmeter) Flameproof (Explosion Protection Code: GF2)
Type of Gas Atmosphere Protection Type of Gas Atmosphere Protection
Ex db eb ia IIC T6...T3 Gb 1Ex db e ia IIC T6...T3 Gb X
(Transmitter Wiring Terminal: M4 screw type) (Transmitter Wiring Terminal: M4 screw type)
Ex db eb ia IIC T6...T3 Gb 1Ex db e ia IIC T6...T3 Gb X
Terminal Compartment: Ex db or Ex eb Terminal Compartment: Ex db or Ex e
(Transmitter Wiring Terminal: Clamp type) (Transmitter Wiring Terminal: Clamp type)
Type of Dust Atmosphere Protection Type of Dust Atmosphere Protection
Ex tb IIIC T75°C...T130°C Db Ex tb IIIC T75°C...T130°C Db X
Enclosure: IP66/IP67 in accordance with IEC 60529 Enclosure: IP66/IP67 in accordance with ГОСТ
Maximum Surface Temperature: 14254
See Table(c) and Table(d). Maximum Surface Temperature:
Ambient Temperature: See Table(c) and Table(d).
See Table(c) and Table(d). Ambient Temperature:
Process Temperature: See Table(c) and Table(d).
See Table(c) and Table(d). Process Temperature:
Power Supply: See Table(c) and Table(d).
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Power Supply:
24 Va.c. (50/60 Hz) / 24 Vd.c. 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Um: 250 V 24 Va.c. (50/60 Hz) / 24 Vd.c.
Current I/O: 4 to 20 mA, 32 Vd.c. max. Um: 250 V
Digital I/O: 30 Vd.c. max., 200 mA max. Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max.
(Remote Sensor) Fieldbus I/O: 32 Vd.c max., 15 mA max.
Type of Gas Atmosphere Protection
Ex db eb ia IIC T6…T3 Gb Flameproof with Intrinsically Safe output
Type of Dust Atmosphere Protection (Explosion Protection Code: GJ2)
Ex tb IIIC T75°C...T150°C Db Type of Gas Atmosphere Protection
1Ex db e ia [ia Ga] IIC T6...T3 Gb X
Enclosure: IP66/IP67 in accordance with IEC 60529 Terminal Compartment: Ex db or Ex e
Maximum Surface Temperature: (Transmitter Wiring Terminal: Clamp type)
See Table(c) and Table(d).
Ambient Temperature: Type of Dust Atmosphere Protection
See Table(c) and Table(d). Ex tb [ia Da] IIIC T75°C...T130°C Db X
Process Temperature:
See Table(c) and Table(d). Enclosure: IP66/IP67 in accordance with ГОСТ
Um: 250 V 14254
Maximum Surface Temperature:
See Table(c) and Table(d).
(Remote Transmitter)
Ambient Temperature:
Type of Gas Atmosphere Protection See Table(c) and Table(d).
Ex db IIC T6 Gb Process Temperature:
(Transmitter Wiring Terminal: M4 screw type) See Table(c) and Table(d).
Ex db IIC T6 Gb or Ex db eb IIC T6 Gb Power Supply:
(Transmitter Wiring Terminal: Clamp type) 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Type of Dust Atmosphere Protection 24 Va.c. (50/60 Hz) / 24 Vd.c.
Ex tb IIIC T75°C Db Electrical parameters:
Terminals: L/+, N/-
Enclosure: IP66/IP67 in accordance with IEC 60529 Um: 250 V
Maximum Surface Temperature: T75°C Terminals: Iout1(+, -), Iout2(+, -)
Ambient Temperature: –40°C to +60°C Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Power Supply: Terminals: P/Sout1(+, -), P/Sout2(+, -)
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
24 Va.c. (50/60 Hz) / 24 Vd.c.
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
21
Flameproof with Intrinsically Safe output for Flameproof with Intrinsically Safe output
FOUNDATION Fieldbus (Explosion Protection Code: GJ2)
(Explosion Protection Code: GT2) Type of Gas Atmosphere Protection
Type of Gas Atmosphere Protection 1Ex db [ia Ga] IIC T6 Gb X or
1Ex db e ia [ia Ga] IIC T6...T3 Gb X 1Ex db e [ia Ga] IIC T6 Gb X
Terminal Compartment: Ex db or Ex e (Transmitter Wiring Terminal: Clamp type)
(Transmitter Wiring Terminal: Clamp type) Type of Dust Atmosphere Protection
Type of Dust Atmosphere Protection Ex tb [ia Da] IIIC T75°C Db X
Ex tb [ia Da] IIIC T75°C...T130°C Db X
Enclosure: IP66/IP67 in accordance with ГОСТ 14254
Enclosure: IP66/IP67 in accordance with ГОСТ 14254 Maximum Surface Temperature: T75°C
Maximum Surface Temperature: Ambient Temperature: –40°C to +60°C
See Table(c) and Table(d). Power Supply:
Ambient Temperature: 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
See Table(c) and Table(d). 24 Va.c. (50/60 Hz) / 24 Vd.c.
Process Temperature: Electrical parameters:
See Table(c) and Table(d). Terminals: L/+, N/-
Power Supply: Um: 250 V
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. Terminals: Iout1(+, -), Iout2(+, -)
24 Va.c. (50/60 Hz) / 24 Vd.c. Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Electrical parameters: Terminals: P/Sout1(+, -), P/Sout2(+, -)
Terminals: L/+, N/- Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Um: 250 V
Terminals: Fieldbus (+, -) Flameproof with Intrinsically Safe output for
FISCO field device or FOUNDATION Fieldbus
Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Terminals: P/Sout1 (+, -) (Explosion Protection Code: GT2)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH Type of Gas Atmosphere Protection
1Ex db [ia Ga] IIC T6 Gb X or
(Remote Sensor) 1Ex db e [ia Ga] IIC T6 Gb X
(Transmitter Wiring Terminal: Clamp type)
Flameproof (Explosion Protection Code: GF2)
Type of Dust Atmosphere Protection
Type of Gas Atmosphere Protection
Ex tb [ia Da] IIIC T75°C Db X
1Ex db e ia IIC T6…T3 Gb X
Type of Dust Atmosphere Protection Enclosure: IP66/IP67 in accordance with ГОСТ
Ex tb IIIC T75°C...T150°C Db X 14254
Maximum Surface Temperature: T75°C
Enclosure: IP66/IP67 in accordance with ГОСТ 14254 Ambient Temperature: –40°C to +60°C
Maximum Surface Temperature: Power Supply:
See Table(c) and Table(d). 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Ambient Temperature: 24 Va.c. (50/60 Hz) / 24 Vd.c.
See Table(c) and Table(d). Electrical parameters:
Process Temperature: Terminals: L/+, N/-
See Table(c) and Table(d). Um: 250 V
Um: 250 V Terminals: Fieldbus (+, -)
FISCO field device or
(Remote Transmitter) Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Flameproof (Explosion Protection Code: GF2) Terminals: P/Sout1 (+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Type of Gas Atmosphere Protection
1Ex db IIC T6 Gb X
(Transmitter Wiring Terminal: M4 screw type)
1Ex db IIC T6 Gb X or 1Ex db e IIC T6 Gb X
(Transmitter Wiring Terminal: Clamp type)
Type of Dust Atmosphere Protection
Ex tb IIIC T75°C Db X

Enclosure: IP66/IP67 in accordance with ГОСТ 14254


Maximum Surface Temperature: T75°C
Ambient Temperature: –40°C to +60°C
Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max.
Fieldbus I/O: 32 Vd.c max., 15 mA max.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
22
NEPSI (Remote Sensor)
Applicable Standard: Flameproof (Explosion Protection Code: NF2)
GB/T 3836.1-2021, GB/T 3836.2-2021, Type of Gas Atmosphere Protection
GB/T 3836.3-2021, GB/T 3836.4-2021, Ex db eb ia IIC T3···T6 Gb
GB/T 3836.31-2021 Type of Dust Atmosphere Protection
Certificate: Ex tb IIIC T75°C···T150°C Db
GYJ23.1319X
Enclosure: IP66/IP67, in accordance with GB 4208
(Integral Flowmeter) Maximum Surface Temperature:
Flameproof (Explosion Protection Code: NF2) See Table (c) and Table (d)
Type of Gas Atmosphere Protection Ambient Temperature:
Ex db eb ia IIC T3···T6 Gb See Table (c) and Table (d)
(Transmitter wiring terminal: M4 screw type) Process Temperature:
Terminal Compartment: Ex db or Ex eb See Table (c) and Table (d)
(Transmitter wiring terminal: clamp type) Um: 250 V
Type of Dust Atmosphere Protection
Ex tb IIIC T75°C···T130°C Db (Remote Transmitter)
Flameproof (Explosion Protection Code: NF2)
Enclosure: IP66/IP67, in accordance with GB 4208 Type of Gas Atmosphere Protection
Maximum Surface Temperature: Ex db IIC T6 Gb
See Table (c) and Table (d) (Transmitter wiring terminal: M4 screw type)
Ambient Temperature: Ex db IIC T6 Gb
See Table (c) and Table (d) Ex db eb IIC T6 Gb
Process Temperature: (Transmitter wiring terminal: clamp type)
See Table (c) and Table (d) Type of Dust Atmosphere Protection
Power Supply: Ex tb IIIC T75°C Db
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c. Enclosure: IP66/IP67, in accordance with GB 4208
Um: 250 V Maximum Surface Temperature: T75°C
Current I/O: 4 to 20 mA, 32 Vd.c. max Ambient Temperature: -40°C to +60°C
Digital I/O: 30 Vd.c. max., 200 mA max Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Flameproof with output IS circuit (Explosion 24 Va.c. (50/60 Hz) / 24 Vd.c.
Protection Code: NJ2) Current I/O: 4 to 20 mA, 32 Vd.c. max
Type of Gas Atmosphere Protection Digital I/O:30 Vd.c. max, 200 mA max.
Ex db eb ia [ia Ga] IIC T3···T6 Gb
Terminal Compartment: Ex db or Ex eb Flameproof with Intrinsically Safe output
Type of Dust Atmosphere Protection (Explosion Protection Code: NJ2)
Ex tb [ia Da] IIIC T75°C···T130°C Db Type of Gas Atmosphere Protection
Ex db [ia Ga] IIC T6 Gb
Enclosure: IP66/IP67, in accordance with GB 4208 Ex db eb [ia Ga] IIC T6 Gb
Maximum Surface Temperature: Type of Dust Atmosphere Protection
See Table (c) and Table (d) Ex tb [ia Da] IIIC T75°C Db
Ambient Temperature:
See Table (c) and Table (d) Enclosure: IP66/IP67, in accordance with GB 4208
Process Temperature: Maximum Surface Temperature: T75°C
See Table (c) and Table (d) Ambient Temperature:- 40°C to +60°C
Power Supply: Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c. 24 Va.c. (50/60 Hz) / 24 Vd.c.
Electrical parameters: Electrical parameters:
Terminals: L/+, N/- Terminals: L/+, N/-
Um: 250 V Um: 250 V
Terminals: Iout1 (+, -), Iout2 (+, -) Terminals: Iout1 (+, -), Iout2 (+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12μH Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Terminals: P/Sout1 (+, -), P/Sout2 (+, -) Terminals: P/Sout1 (+, -), P/Sout2 (+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12μH Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
23
Table (c): Temperature Table (IECEx, FM (USA), Korea, INMETRO, EAC, NEPSI)

Temperature Table*1
Process
Model Size Lining Integral Remote
Connection
Flowmeter Sensor
AXG002, AXG005, 2.5 to 15 mm
Wafer, Flange PFA Lining Table A Table C
AXG010, AXG015 (0.1 to 0.5 in.)
AXG025, AXG032,
AXG040, AXG050, 25 to 125 mm Table B Table D
Wafer, Flange PFA Lining
AXG065, AXG080, (1 to 5 in.) [Table I]*2 [Table I]*2
AXG100, AXG125
AXG150, AXG200,
150 to 400 mm
AXG250, AXG300, Wafer, Flange PFA Lining Table A Table C
(6 to 16 in.)
AXG350, AXG400
AXG015, AXG025,
AXG032, AXG040,
15 to 125 mm Clamp, Union,
AXG050, AXG065, PFA Lining Table E Table F
(0.5 to 5 in.) Butt Weld Joint
AXG080, AXG100,
AXG125
AXG002, AXG005,
AXG010, AXG015,
AXG025, AXG040, 2.5 to 200 mm
Wafer Ceramics Tube Table G Table H
AXG050, AXG080, (0.1 to 8 in.)
AXG100, AXG150,
AXG200
*1: For details, see Table No. on Table (d).
*2: When process connection EA4 is specified, table specified inside [] is applied.
Process connection EA4 can be applicable for AXG025, AXG040, AXG050, AXG080 and AXG100.

Table (d): Temperature Table (IECEx, FM (USA), Korea, INMETRO, EAC, NEPSI)

Ambient Temperature Maximum Surface Process


Table No.
Temperature Class Temperature Temperature
T6 T75°C -40°C to +75°C
T5 T90°C -40°C to +90°C
A -40°C to +60°C
T4 T120°C -40°C to +120°C
T3 T130°C -40°C to +130°C
-40°C to +45°C T6 T75°C -40°C to +50°C
T5 T90°C -40°C to +75°C
B
-40°C to +60°C T4 T120°C -40°C to +120°C
T3 T130°C -40°C to +130°C
T6 T75°C -40°C to +75°C
T5 T90°C -40°C to +90°C
C -40°C to +60°C
T4 T120°C -40°C to +120°C
T3 T150°C -40°C to +150°C
-40°C to +45°C T6 T75°C -40°C to +50°C
T5 T90°C -40°C to +75°C
D
-40°C to +60°C T4 T120°C -40°C to +120°C
T3 T150°C -40°C to +150°C
-10°C to +45°C T6 T75°C -10°C to +50°C
T5 T90°C -10°C to +75°C
E
-10°C to +60°C T4 T120°C -10°C to +120°C
T3 T130°C -10°C to +130°C
-10°C to +45°C T6 T75°C -10°C to +50°C
T5 T90°C -10°C to +75°C
F
-10°C to +60°C T4 T120°C -10°C to +120°C
T3 T150°C -10°C to +150°C
T6 T75°C -10°C to +75°C
T5 T90°C -10°C to +90°C
G -10°C to +60°C
T4 T120°C -10°C to +120°C
T3 T130°C -10°C to +130°C
T6 T75°C -10°C to +75°C
T5 T90°C -10°C to +90°C
H -10°C to +60°C
T4 T120°C -10°C to +120°C
T3 T150°C -10°C to +150°C
T6 T75°C -10°C to +75°C
T5 T90°C -10°C to +90°C
I -10°C to +60°C
T4 T120°C -10°C to +100°C
T3 T150°C -10°C to +100°C

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
24
FM (Canada) Power Supply:
Applicable Standard: 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
CAN/CSA-C22.2 No. 0, CAN/CSA-C22.2 No. 0.4, 24 Va.c. (50/60 Hz) / 24 Vd.c.
C22.2 No. 0.5, C22.2 No. 25, C22.2 No. 30, C22.2 Electrical parameters:
No. 94.2, CAN/CSA-C22.2 No. 61010-1, CAN/ Terminals: L/+, N/-
CSA-C22.2 No. 61010-2-030, C22.2 No. 60079-0, Um: 250 V
CAN/CSA-C22.2 No. 60079-7, CAN/CSA-C22.2 Terminals: Iout1 (+, -), Iout2 (+, -)
No. 60079-11, CAN/CSA-C22.2 No. 60079-18, Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
ANSI/ISA-12.27.01 Terminals: P/Sout1 (+, -), P/Sout2 (+, -)
Certificate: Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
FM 17CA0076X Process Sealing: Dual seal
Primary Seal Failure Annunciation:
(Integral Flowmeter) For the purpose of failure annunciation, the
process fluid must be conductive.
Explosionproof (Explosion Protection Code: CF2) If the Primary Seal fails, a significant change of
Explosionproof and Ignition Protected Apparatus impedance occurs between the electrodes and the
for Class I, Division 1, Groups B, C and D. housing.
Dust-Ignitionproof for Class II,III, Division 1, This is detected as:
Groups E, F and G. - significant decrease of the flow rate output signal
with Intrinsically Safe Electrodes for Class I, when the process fluid is flowing; or
Division 1, Groups A, B, C and D. - unusual fluctuation of the flow rate output signal
Temperature Class T6…T3. when the process fluid is not flowing.
Enclosure: Type 4X
Ambient Temperature: Explosionproof with Intrinsically Safe output for
See Table (e) and Table (f). FOUNDATION Fieldbus / PROFIBUS PA
Process Temperature: (Explosion Protection Code: CT2)
See Table (e) and Table (f). Type of Protection:
Power Supply: Explosionproof and Ignition Protected Apparatus
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c. for Class I, Division 1, Groups B, C and D.
24 Va.c. (50/60 Hz) / 24 Vd.c. Dust-Ignitionproof for Class II,III, Division 1,
Um: 250 V Groups E, F and G.
Current I/O: 4 to 20 mA, 32 Vd.c. max. with Intrinsically Safe Electrodes for Class I,
Digital I/O: 30 Vd.c. max., 200 mA max. Division 1, Groups A, B, C and D.
Fieldbus I/O: 32 Vd.c. max., 15 mA max. Associated Apparatus for Class I,II,III, Division 1,
Modbus I/O: 5 Vd.c. typ. Groups A, B, C, D, E, F and G.
Process Sealing: Dual seal Temperature Class T6…T3.
Primary Seal Failure Annunciation:
For the purpose of failure annunciation, the Enclosure: Type 4X
process fluid must be conductive. Ambient Temperature:
If the Primary Seal fails, a significant change of See Table (e) and Table (f).
impedance occurs between the electrodes and the Process Temperature:
housing. See Table (e) and Table (f).
This is detected as: Power Supply:
- significant decrease of the flow rate output signal 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
when the process fluid is flowing; or 24 Va.c. (50/60 Hz) / 24 Vd.c.
- unusual fluctuation of the flow rate output signal Electrical parameters:
when the process fluid is not flowing. Terminals: L/+, N/-
Um: 250 V
Explosionproof with Intrinsically Safe output Terminals: Fieldbus (+, -)
(Explosion Protection Code: CJ2) FISCO field device or
Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Type of Protection: Terminals: P/Sout1 (+, -)
Explosionproof and Ignition Protected Apparatus Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
for Class I, Division 1, Groups B, C and D. Process Sealing: Dual seal
Dust-Ignitionproof for Class II,III, Division 1, Primary Seal Failure Annunciation:
Groups E, F and G. For the purpose of failure annunciation, the
with Intrinsically Safe Electrodes for Class I, process fluid must be conductive.
Division 1, Groups A, B, C and D. If the Primary Seal fails, a significant change of
Associated Apparatus for Class I,II,III, Division 1, impedance occurs between the electrodes and the
Groups A, B, C, D, E, F and G. housing.
Temperature Class T6…T3. This is detected as:
- significant decrease of the flow rate output signal
Enclosure: Type 4X when the process fluid is flowing; or
Ambient Temperature: - unusual fluctuation of the flow rate output signal
See Table (e) and Table (f). when the process fluid is not flowing.
Process Temperature:
See Table (e) and Table (f).

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
25
(Remote Sensor) Enclosure: Type 4X
Explosionproof (Explosion Protection Code: CF2) Ambient Temperature: –40°C to +60°C
Power Supply:
Type of Protection: 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
Explosionproof and Ignition Protected Apparatus 24 Va.c. (50/60 Hz) / 24 Vd.c.
for Class I, Division 1, Groups B, C and D. Electrical parameters:
Dust-Ignitionproof for Class II,III, Division 1, Terminals: L/+, N/-
Groups E, F and G. Um: 250 V
with Intrinsically Safe Electrodes for Class I, Terminals: Iout1 (+, -), Iout2 (+, -)
Division 1, Groups A, B, C and D. Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 4.84 nF, Li: 12 μH
Temperature Class T6…T3. Terminals: P/Sout1 (+, -), P/Sout2 (+, -)
Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Enclosure: Type 4X
Ambient Temperature:
See Table (e) and Table (f). Explosionproof with Intrinsically Safe output for
Process Temperature: FOUNDATION Fieldbus / PROFIBUS PA
See Table (e) and Table (f). (Explosion Protection Code: CT2)
Um: 250 V Type of Protection:
Process Sealing: Dual seal Explosionproof for Class I, Division 1, Groups A, B,
Primary Seal Failure Annunciation: C and D.
For the purpose of failure annunciation, the Dust-Ignitionproof for Class II,III, Division 1,
process fluid must be conductive. Groups E, F and G.
If the Primary Seal fails, a significant change of Associated Apparatus for Class I,II,III, Division 1,
impedance occurs between the electrodes and the Groups A, B, C, D, E, F and G.
housing. Temperature Class T6.
This is detected as:
- significant decrease of the flow rate output signal Enclosure: Type 4X
when the process fluid is flowing; or Ambient Temperature: –40°C to +60°C
- unusual fluctuation of the flow rate output signal Power Supply:
when the process fluid is not flowing. 100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
(Remote Transmitter) Electrical parameters:
Terminals: L/+, N/-
Explosionproof (Explosion Protection Code: CF2) Um: 250 V
Type of Protection: Terminals: Fieldbus (+, -)
Explosionproof for Class I, Division 1, Groups A, B, FISCO field device or
C and D. Ui: 30 V, Ii: 380 mA, Pi: 5.32 W, Ci: 5 nF, Li: 10 μH
Dust-Ignitionproof for Class II,III, Division 1, Terminals: P/Sout1 (+, -)
Groups E, F and G. Ui: 30 V, Ii: 300 mA, Pi: 1.25 W, Ci: 14.6 nF, Li: 12 μH
Temperature Class T6.

Enclosure: Type 4X
Ambient Temperature: –40°C to +60°C
Power Supply:
100 to 240 Va.c. (50/60 Hz) / 100 to 120 Vd.c.
24 Va.c. (50/60 Hz) / 24 Vd.c.
Current I/O: 4 to 20 mA, 32 Vd.c. max.
Digital I/O: 30 Vd.c. max., 200 mA max.
Fieldbus I/O: 32 Vd.c. max., 15 mA max.
Modbus I/O: 5 Vd.c. typ.

Explosionproof with Output IS Circuit


(Explosion Protection Code: CJ2)
Type of Protection:
Explosionproof for Class I, Division 1, Groups A, B,
C and D.
Dust-Ignitionproof for Class II,III, Division 1,
Groups E, F and G.
Associated Apparatus for Class I,II,III, Division 1,
Groups A, B, C, D, E, F and G.
Temperature Class T6.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
26
Table (e): Temperature Table (FM (Canada))

Temperature Table*
Process Integral
Model Size Lining Remote
Connection
Flowmeter Sensor
AXG002, AXG005, 2.5 to 15 mm
Wafer, Flange PFA Lining Table A Table C
AXG010, AXG015 (0.1 to 0.5 in.)
AXG025, AXG032,
AXG040, AXG050, 25 to 125 mm
Wafer, Flange PFA Lining Table B Table D
AXG065, AXG080, (1 to 5 in.)
AXG100, AXG125
AXG150, AXG200,
150 to 400 mm
AXG250, AXG300, Wafer, Flange PFA Lining Table A Table C
(6 to 16 in.)
AXG350, AXG400
AXG015, AXG025,
AXG032, AXG040,
15 to 125 mm Clamp, Union,
AXG050, AXG065, PFA Lining Table E Table F
(0.5 to 5 in.) Butt Weld Joint
AXG080, AXG100,
AXG125
*: For details, see Table No. on Table (f).

Table (f): Temperature Table (FM (Canada))

Ambient Temperature Maximum Surface Process


Table No.
Temperature Class Temperature Temperature
T6 T75°C -40°C to +75°C
T5 T90°C -40°C to +90°C
A -40°C to +60°C
T4 T120°C -40°C to +120°C
T3 T130°C -40°C to +130°C
-40°C to +45°C T6 T75°C -40°C to +50°C
T5 T90°C -40°C to +75°C
B
-40°C to +60°C T4 T120°C -40°C to +120°C
T3 T130°C -40°C to +130°C
T6 T75°C -40°C to +75°C
T5 T90°C -40°C to +90°C
C -40°C to +60°C
T4 T120°C -40°C to +120°C
T3 T150°C -40°C to +150°C
-40°C to +45°C T6 T75°C -40°C to +50°C
T5 T90°C -40°C to +75°C
D
-40°C to +60°C T4 T120°C -40°C to +120°C
T3 T150°C -40°C to +150°C
-10°C to +45°C T6 T75°C -10°C to +50°C
T5 T90°C -10°C to +75°C
E
-10°C to +60°C T4 T120°C -10°C to +120°C
T3 T130°C -10°C to +130°C
-10°C to +45°C T6 T75°C -10°C to +50°C
T5 T90°C -10°C to +75°C
F
-10°C to +60°C T4 T120°C -10°C to +120°C
T3 T150°C -10°C to +150°C

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
27
n PERFORMANCE Sizes 25 to 200 mm (1 to 8 in.)
Accuracy: High Grade Accuracy (Accuracy Code C)

• AXG Integral Flowmeter, or combination of AXG % of rate


1.2
Remote Sensor and AXG4A Remote Transmitter
(except optional code HF2) 1.0

Size Flow Velocity Standard Accuracy 0.8


mm (in.) V m/s (ft/s) (Accuracy Code B)
0.6
V < 0.3 (1) ±1.0 mm/s
2.5 to 15
(0.1) (0.5) 0.3 ≤ V ≤ 10 0.4
±0.3 % of rate
(1) (33)
0.2
V < 0.15 (0.5) ±0.5 mm/s
25 to 400
(1) (16) 0.15 ≤ V ≤ 10 0.0
±0.3 % of rate
(0.5) (33) 0 1 2 3 4 5 6 7 8 9 10
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33)
V m/s (ft/s) F04.ai
Size Flow Velocity High Grade Accuracy
mm (in.) V m/s (ft/s) (Accuracy Code C)
• AXG Integral Flowmeter, or combination of AXG
V < 0.15 (0.5) ±0.5 mm/s Remote Sensor and AXG1A Remote Transmitter
0.15 ≤ V < 1 (except optional code HF2)
25 to 200 ±0.18% of rate ± 0.2 mm/s
(0.5) (3.3)
(1) (8)
1 ≤ V ≤ 10 Size Flow Velocity Standard Accuracy
±0.15% of rate mm (in.) V m/s (ft/s) (Accuracy Code B)
(3.3) (33)
V < 0.3 (1) ±1.0 mm/s
2.5 to 15
Sizes 2.5 to 15 mm (0.1 to 0.5 in.) (0.1) (0.5) 0.3 ≤ V ≤ 10
Standard Accuracy (Accuracy Code B) ±0.3 % of rate
(1) (33)
% of rate V < 0.15 (0.5) ±0.5 mm/s
25 to 400
1.2
(1) (16) 0.15 ≤ V ≤ 10
±0.3 % of rate
(0.5) (33)
1.0
V < 0.3 (1) ±2.0 mm/s
500
0.8
(20) 0.3 ≤ V ≤ 10
±0.35% of rate ±1.0 mm/s
(1) (33)
0.6

0.4 Size Flow Velocity High Grade Accuracy


mm (in.) V m/s (ft/s) (Accuracy Code C)
0.2
V < 0.15 (0.5) ±0.5 mm/s
0.0 0.15 ≤ V < 1
0 1 2 3 4 5 6 7 8 9 10 25 to 200 ±0.18% of rate ± 0.2 mm/s
(0.5) (3.3)
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33) (1) (8)
1 ≤ V ≤ 10
V m/s (ft/s) F02.ai ±0.15% of rate
(3.3) (33)

Sizes 25 to 400 mm (1 to 16 in.) • Combination of AXG Remote Sensor and AXFA11


Standard Accuracy (Accuracy Code B) Remote Transmitter
% of rate
1.2
Size Flow Velocity Standard Accuracy
mm (in.) V m/s (ft/s) (Accuracy Code B)
1.0 V < 0.3 (1) ±1.0 mm/s
2.5 to 15
(0.1) (0.5) 0.3 ≤ V ≤ 10
0.8 ±0.35 % of rate
(1) (33)
0.6 V < 0.15 (0.5) ±0.5 mm/s
25 to 400
(1) (16) 0.15 ≤ V ≤ 10
0.4 ±0.35 % of rate
(0.5) (33)
0.2 V < 0.3 (1) ±2.0 mm/s
500
(20) 0.3 ≤ V ≤ 10
0.0 ±0.35% of rate ±1.0 mm/s
0 1 2 3 4 5 6 7 8 9 10 (1) (33)
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33)
V m/s (ft/s) F03.ai
Size Flow Velocity High Grade Accuracy
mm (in.) V m/s (ft/s) (Accuracy Code C)
V < 0.15 (0.5) ±0.5 mm/s
0.15 ≤ V < 1
25 to 200 ±0.18% of rate ± 0.2 mm/s
(0.5) (3.3)
(1) (8)
1 ≤ V ≤ 10
±0.2% of rate
(3.3) (33)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
28
• AXG Integral Flowmeter, combination of AXG
Sizes 2.5 to 15 mm (0.1 to 0.5 in.)
with AXFA11 Standard Accuracy (Accuracy Code B) Remote Sensor and AXG4A or AXG1A Remote
Transmitter (combined with optional code HF2)
% of rate
1.2 Size Flow Velocity Standard Accuracy
mm (in.) V m/s (ft/s) (Accuracy Code B)
1.0
V < 0.15
±1.5 mm/s
0.8 25 to 200 (0.5)
(1) (8) 0.15 ≤ V ≤ 10
0.6 ±0.35% of rate ± 1 mm/s
(0.5) (33)
0.4 Sizes 25 to 200 mm (1 to 8 in.)
Combined with optional code HF2
0.2
% of rate
0.0 1.2
0 1 2 3 4 5 6 7 8 9 10
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33) 1.0
V m/s (ft/s) F05.ai
0.8
Sizes 25 to 400 mm (1 to 16 in.)
with AXFA11 Standard Accuracy (Accuracy Code B) 0.6

% of rate 0.4
1.2
0.2
1.0
0.0
0.8 0 1 2 3 4 5 6 7 8 9 10
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33)
0.6 V m/s (ft/s) F09.ai

Note: The accuracy above is the result of calibration test at our


0.4
water flow facility before shipment. It is defined by the
0.2
integrated value of the pulse output. As for the current output
accuracy, add ±8 μA (±0.05% of span) to the accuracy above.
0.0 Calibration takes place at reference conditions as below.
0 1 2 3 4 5 6 7 8 9 10 Medium: Water
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33) Density: 0.9 to 1.1 kg/l
V m/s (ft/s) F06.ai Medium temperature: 10 to 35°C (50 to 95°F)
Ambient temperature: 10 to 35°C (50 to 95°F)
Size 500 mm (20 in.) Reference Standards:
with AXFA11 Standard Accuracy (Accuracy Code B) JIS B 7554, ISO 4185, ISO 5168, ISO 20456,
% of rate BS EN 29104
1.2 Note: Refer to the table below for accuracy grades for export to China.
Size Flow Velocity
1.0 Accuracy grade
mm (in.) V m/s (ft/s)
V < 0.3 (1) Grade 1
0.8 2.5 to 15
0.3 ≤ V ≤ 10
(0.1) (0.5) Grade 0.5
0.6 (1) (33)
25 to 300
V ≤ 10 (33) Grade 0.5
0.4 (1) (12)
* No accuracy grade applies to size larger than 300 mm.
0.2 * When optional code HF2 is selected, the accuracy grade
is not applicable.
0.0
0 1 2 3 4 5 6 7 8 9 10 Repeatability:
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33) For size 2.5 mm (0.1 in.) to 400 mm (16 in.)
V m/s (ft/s) F07.ai ±0.1% of rate (Velocity 1 m/s (3.3 ft/s) or above)
±0.05% of rate ± 0.5 mm/s (Velocity below 1 m/s (3.3 ft/s))
Sizes 25 to 200 mm (1 to 8 in.)
with AXFA11 High Grade Accuracy (Accuracy Code C)
Size 500 mm (20 in.)
± 0.2% of rate (Velocity 1 m/s (3.3 ft/s) or above)
% of rate
± 0.1% of rate± 1 mm/s (Velocity below 1 m/s (3.3 ft/s))
1.2 Measurement Range:
1.0
Minimum Span Velocity: 0.1 m/s (0.33 ft/s)
0.5 m/s (1.64 ft/s) when option E21 is applied
0.8 Maximum Span Velocity: 10 m/s (33 ft/s)
Note: For details of span flow rate, read "Sizing Data", and
0.6 "Ordering Information".
Power Consumption:
0.4
Integral Type: 13 W
0.2 Remote Type:
13 W (with AXG4A Remote Transmitter)
0.0 32 W (with AXG1A Remote Transmitter)
0 1 2 3 4 5 6 7 8 9 10
(0.0) (3.3) (6.6) (9.8) (13) (16) (20) (23) (26) (30) (33) 20 W (with AXFA11 Remote Transmitter)
Note: The power consumption is the same as above
V m/s (ft/s) F08.ai
regardless of the communication and I/O type.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
29
Insulation Resistance: Between power supply terminals and input/output
Integral Flowmeter: terminals:
Between power supply terminals and ground 1400 V AC for 2 seconds
terminal: Between excitation current terminal and ground
100 MΩ/500 V DC terminal:
Between power supply terminals and input/output 160 V AC for 2 seconds
terminals: Between excitation current terminal and input/
100 MΩ/500 V DC output terminals:
Between ground terminal and input/output 350 V AC for 2 seconds
terminals:
20 MΩ/100 V DC or 125 V DC
Between input/output terminals*:
n NORMAL OPERATING CONDITIONS
20 MΩ/100 V DC or 125 V DC Ambient Temperature:
*: Not applicable for I/O3 and I/O4+ of Modbus –40 to 60°C (–40 to 140°F)
Remote Sensor: Note: Minimum value is limited according to minimum fluid
Between signal terminals*: temperature of sensor's specification. Read “Fluid
100 MΩ/500 V DC Temperature and Pressure”.
Display operating range is –20 to 60°C (–4 to 140°F).
Between signal terminals and common terminal*:
Refer to the HAZARDOUS AREA CLASSIFICATION for
100 MΩ/500 V DC Explosion protection type.
*: Not applicable for Explosion protection type
Between excitation current terminal and signal / Ambient Humidity:
common terminals: 0 to 100%
100 MΩ/500 V DC Note: Lengthy continuous operation at 95% or more is not
recommended.
Remote Transmitter:
Between power supply terminals and ground terminal: Power Supply:
100 MΩ/500 V DC Power Supply Code 1:
Between power supply terminals and input/output AC Type:
or excitation current terminals: Rated Power Supply: 100 to 240 V AC, 50/60 Hz
100 MΩ/500 V DC Operating Voltage Range: 80 to 264 V AC
Between ground terminal and input/output or DC Type:
excitation current terminals: Rated Power Supply: 100 to 120 V DC
20 MΩ/100 V DC or 125 V DC Operating Voltage Range: 90 to 130 V DC
Between input/output* and excitation current terminals: Power Supply Code 2:
20 MΩ/100 V DC or 125 V DC AC Type:
*: Not applicable for I/O3 and I/O4+ of Modbus Rated Power Supply: 24 V AC, 50/60 Hz
Withstand Voltage: Operating Voltage Range: 20.4 to 28.8 V AC
Integral Flowmeter: DC Type:
Between power supply terminals and ground Rated Power Supply: 24 V DC
terminal: Operating Voltage Range: 20.4 to 28.8 V DC
1400 V AC for 2 seconds Supply Voltage and Power Supply Cable Length
Between power supply terminals and input/output for Power Supply Code 2:
terminals: 700 (2290)
1400 V AC for 2 seconds
Allowable cable length m(ft)

603 (1970)
Remote Sensor (Optional code WT1): 600 (1960)
Between excitation current terminal and ground 500 (1640)
terminal:
400 (1310)
1000 V AC for 1 minute 338 (1100)
Remote Sensor (Optional code WT2): 300 (980)
Between excitation current terminal and ground 200 (650)
terminal:
100 (320)
1500 V AC for 1 minute
Between signal terminals and excitation current 0
28.8
terminal: 20 22 24 26 28 30
1500 V AC for 1 minute Usable voltage range (V)
Remote Sensor (Explosion protection type): Cable cross section area: 1.25 mm2
Between excitation current terminal and ground Cable cross section area: 2 mm2
terminal: F10.ai

1500 V AC for 1 minute, or 1800 V AC for 0.2 Note: For AXG1A remote transmitter, read general
second specifications (GS 01E22C01-01EN).
Between signal terminals and excitation current Fluid Conductivity:
terminal: Size 2.5 to 10 mm (0.1 to 0.4 in.): 5 μS/cm or larger
1500 V AC for 1 minute, or 1800 V AC for 0.2 Size 15 to 125 mm (0.5 to 5 in.): 1 μS/cm or larger
second Size 150 to 400 mm (6 to 16 in.): 3 μS/cm or larger
Remote Transmitter: Size 500 mm (20 in.): 20 μS/cm or larger
Between power supply terminals and ground Note: For measuring low conductivity fluids, read "Cautions
terminal: on Selection and Installation".
1400 V AC for 2 seconds

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
30
Signal Cable Length and Fluid Conductivity Fluid Temperature and Pressure:
(Remote Sensor): The following figure shows the usable temperature
Sizes 2.5 to 10 mm (0.1 to 0.4 in.) and pressure range of the sensor in each
specification. It is also limited by the flange pressure
Add ±1% of rate to the As show in accuracy rating of the process connection.
Cable length m (ft)

accuracy shown in description


accuracy description For fluid temperature of the Explosion Protection,
Combined read descriptions of “Explosion Protection”.
100 (330) with AXG4A
or AXG1A PFA Lining, Remote Sensor (excluding high
50 (170) or AXFA11
transmitter
pressure type (ASME Class 600 flange) and
3 (10) Hygienic)
0 (0)
1 5 10 20 50
Fluid conductivity (μS/cm) 2.5 to 50 mm (0.1 to 2 in.) (flange type, wafer type)
F11.ai
65 to 200 mm (2.5 to 8 in.) (flange type, wafer type)
Sizes 15 to 125 mm (0.5 to 5 in.) 250 to 300 mm (10 to 12 in.) (flange type)
Add ±1% of rate to the As show in accuracy Pressure
accuracy shown in 350 to 500 mm (14 to 20 in.) (flange type)
description MPa (psi)
accuracy description
200 (660) 4 (580)
Cable length m (ft)

Combined with
AXG1A or AXFA11 *1
transmitter
100 (330) Combined with
AXG4A 2 (290)
transmitter
25 (85) 1 (145)
0 (0)
1 3 5
Fluid conductivity (μS/cm) – 0.1 (–14.5)
F12.ai – 40 –10 0 40 100 130 160
(–40) (14) (32) (104) (212) (266) (320)
Sizes 150 to 400 mm (6 to 16 in.)
Temperature °C (°F) F15.ai
Add ±1% of rate to the As show in accuracy
accuracy shown in description
accuracy description
PFA Lining, Integral Flowmeter (excluding high
200 (660) Combined with
Cable length m (ft)

AXG1A or AXFA11 pressure type (ASME Class 600 flange), and


transmitter Hygienic)
100 (330) Combined with
AXG4A 2.5 to 50 mm (0.1 to 2 in.) (flange type, wafer type)
50 (170) transmitter
65 to 200 mm (2.5 to 8 in.) (flange type, wafer type)
25 (85)
0 (0) 250 to 300 mm (10 to 12 in.) (flange type)
1 3 5 10
Fluid conductivity (μS/cm)
Pressure 350 to 400 mm (14 to 16 in.) (flange type)
F13.ai MPa (psi)
Size 500 mm (20 in.) 4 (580)
*1
200 (660)
Cable length m (ft)

Combined with
2 (290)
AXG1A or AXFA11 transmitter
1 (145)
100 (330)

– 0.1 (–14.5)
– 40 –10 0 40 100 130
0 (– 40) (14) (32) (104) (212) (266)
20
Temperature °C (°F) F16.ai
Fluid conductivity (μS/cm) F14.ai
*1: For wafer types of 150 to 200 mm (6 to 8 in.) or
carbon steel flange types (process connection code:
C##) of 50 to 500 mm (2 to 20 in.), the minimum
temperature is –10°C (14°F).

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
31
PFA Lining, Remote Sensor and Integral Flowmeter Thermal Shock Temperature and Flow Velocity of
(high pressure type (ASME Class 600 flange)) Ceramics Tube:
Sizes 2.5 to 25 mm (0.1 to 1 in.)
Pressure
MPa (psi) ∆T°C(°F)
120 (248)
10 (1450)
9.92 (1440) Increase
100 (212)
8.27 (1200)
8.15 (1182)

Decrease
60 (140)

0 1 (3.3) 5 (16) 10 (33)


Flow Velocity m/s(ft/s)
Sizes 40 to 50 mm (1.5 to 2 in.)
∆T°C(°F) Increase
100 (212)
90 (162)
-0.1 (-14.5) 0 50 100
-10 (32) 37.8 (122) 93.3(212)
(14) (100) (200)
Temperature °C (°F) F17.ai
50 (122)
Decrease
PFA Lining, Remote Sensor and Integral Flowmeter 30 (86)
(Hygienic)
0 1 (3.3) 5 (16) 10 (33)
15 to 125 mm (0.5 to 5 in.) (remote sensor)
Pressure Flow Velocity m/s(ft/s)
15 to 125 mm (0.5 to 5 in.) (integral flowmeter)
MPa (psi) Sizes 80 to 200 mm (3 to 8 in.)
∆T°C(°F) Increase
1(145)
70 (158)

50 (122)
–0.1(–14.5) Decrease
–10 0 130 160 30 (86)
(14) (32) (266) (320)
Temperature °C (°F) F18.ai
0 1 (3.3) 5 (16) 10 (33)
Flow Velocity m/s(ft/s) F21.ai
Note: For fluid temperature of 120°C (248°F) or more
(Maximum: 160°C (320°F)), select optional code GH. “Decrease” means that the temperature of a measured
Ceramics Tube, Remote Sensor fluid drops rapidly, while “Increase” means that the
temperature rises rapidly. The maximum allowable
Pressure 2.5 to 50 mm (0.1 to 2 in.) ranges in both cases are indicated by the curves
MPa (psi) 80 to 200 mm (3 to 8 in.)
shown in the diagrams, with the solid line indicating the
4 (580) maximum increase, and the broken line the maximum
decrease.
ΔT: Change in temperature of measured fluid in one
2 (290) second
Flow velocity: Flow velocity of the measured fluid
Allowable Conditions for Cleaning Lining
–0.1 (–14.5)
–10 0 100 180 (Hygienic, and Hygienic Explosion Protection):
(14) (32) (212) (356) Steam or hot water cleaning:
Temperature °C (°F) Max. temp. 150°C (302°F), time period 60 minutes
F19.ai
or less
· When Use code -H (Hygienic) with Construction
Ceramics Tube, Integral Flowmeter
code D/E/G (Remote sensor) is specified, it can
Pressure 2.5 to 50 mm (0.1 to 2 in.) be cleaned at Max. temp 160°C (320°F).
MPa (psi) 80 to 200 mm (3 to 8 in.) · When Use code -J (Hygienic Explosion
4 (580)
Protection) is specified, clean after the power is
turned off.
3.25 (471)
Vibration Conditions:
2 (290) Integral Flowmeter:
19.6 m/s2 - rms (5 to 2000 Hz)
Remote Sensor:
34.3 m/s2 - rms (5 to 2000 Hz)
–0.1(–14.5) Remote Transmitter:
–10 0 100 130 19.6 m/s2 - rms (5 to 2000 Hz)
(14) (32) (212)(266)
Note: Vibration conditions are based on IEC 60068-2-64.
Temperature °C (°F) Avoid installation in a place with much vibration
F20.ai
(vibration frequency 2000 Hz or more). It may cause
damage to the device.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
32
n CAUTIONS ON SELECTION AND
INSTALLATION
Combined Transmitter:
In the following cases, combine with AXG1A or
AXFA11G remote transmitter. If it is considered that
the flow noise in the fluid could be large because
of low conductivity, or high concentration slurry,
etc. and the size is 250 mm (10 in.) or more, it is
recommended to combine with AXG1A or AXFA11G
remote transmitter.
· When mounting remote transmitter to wall or panel
· When cable length exceeds 100 m
· When using 5 or more input/output terminals
Wiring:
For the power code (-1 100-240 V AC / 100 - 120 V
DC), don't bundle the power supply wire and other
signal wire into the same wiring port.
Lining:
PFA Lining:
It is excellent in chemical resistance. We adopt
the material approved by FDA (US Food and Drug
Administration).
Ceramics Tube:
It is excellent in chemical resistance, heat
resistance and abrasion resistance. Measuring
pipe sintered with high purity alumina ceramics is a
structure that also serves as a lining.
Grounding Device:
The grounding device can be selected as an optional
specification. It is unnecessary to use it for metal
piping which has no lining. In that case, connect
the piping and the sensor flange part (mini-flange
or one-piece casting structured measuring pipe
for wafer type) with grounding wire supplied by
customer (see the figure below). Be sure to select the
grounding device when installed at plastic or lining
piping.

F22.ai

There are thin type (thickness 1 to 2 mm) and thick


type (thickness 3 to 4 mm, or 8.5 to 10.5 mm for
high pressure type) for grounding rings. If the flange
is ASME Class 300, EN PN 40 etc. for high fluid
pressure and the tightening torque is high, the thick
type is recommended.
Grounding ring (electrode type) and built-in grounding
electrode can not be used for permeable fluid (e.g.
nitric acid, hydrofluoric acid, high temperature sodium
hydroxide etc.).
The built-in grounding electrode (for sizes 150 to 400
mm, 6 to 16 in.) has fewer seals against fluid than the
grounding ring, so leakage possibility will be less if
the installed piping is plastic or lining one.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
33
Recommended Gasket (for installed piping flange):
Use compressed non-asbestos joint sheet gaskets, PTFE-sheathed non-asbestos joint sheet gaskets or gaskets
which have equivalent elasticity. When selecting optional code GA, GC, or GD for plastic piping, use rubber gaskets
or ones which have equivalent elasticity (such as PTFE-sheathed rubber gaskets).
Dimensions of the gasket should be determined with reference to the following table (by process connection and lining)
and figure. If the inner diameter of the gasket is too large or the outer diameter is too small, liquid leakage may occur.
Unit: mm
PFA Lining Ceramics Tube
Wafer Flange Wafer
Inner Outer Recommended Inner Minimum Inner Outer Recommended Inner Inner Outer Recommended Inner
Size Diameter Diameter Diameter of Gasket Diameter Diameter Diameter of Gasket Minimum Diameter Diameter Diameter of Gasket Minimum
Inner Inner Inner
for for PTFE- for for PTFE- Diameter for for PTFE- Diameter
Flat Diameter Effective Flat Flat
Effective Effective Effective Effective Effective
Gasket sheathed Gasket sheathed
of of sheathed of
Sealing Sealing Sealing Sealing Gasket
Gasket Gasket* 2 Gasket Gasket*2 Sealing Sealing Gasket Gasket*2
[øA] [øB] [øC] [øA] [øB] [øC] [øA] [øB] [øC]
[øD] [øD] [øD]
2.5 15 38 17 22 15 15 30 17 [15]*1 22 [19]*1 15 ― ― ― ―
5 15 38 17 22 15 15 30 17 [15]*1 22 [19]*1 15 ― ― ― ―
1 1
10 15 38 17 22 15 15 30 17 [15]* 22 [19]* 15 ― ― ― ―
15 18 38 22 15 22 34 22 15 15 33 22 15
25 32 54 35 28 35 54 35 29 27 50 35 27
32 37 58 43 34 40 64 43 34 ― ― ― ―
40 45 71 49 41 48 72 49 41 40 68 49 40
50 58 84 61 53 61 89 61 53 52 82 61 52
65 69 103 84 66 72 108 84 66 ― ― ― ―
80 81 114 90 81 85 119 90 81 81 112 90 81
100 106 140 115 102 110 146 115 102 98 134 115 98
125 131 165 141 128 136 173 141 128 ― ― ― ―
150 164 190 167 147 164 209 {216}*1 167 150 144 188 167 144
200 218 240 218 199 218 259 {272}*1 218 201 192 240 218 192
250 ― ― ― ― 270 320 {332}*1 270 250 ― ― ― ―
300 ― ― ― ― 321 367 {392}*1 321 301 ― ― ― ―
350 ― ― ― ― 350 412 359 330 ― ― ― ―
400 ― ― ― ― 401 475 410 381 ― ― ― ―
500 ― ― ― ― 581 581 <606>*1 513 465 ― ― ― ―

Unit: inch
PFA Lining Ceramics Tube
Wafer Flange Wafer
Inner Outer Recommended Inner Minimum Inner Outer Recommended Inner Inner Outer Recommended Inner
Size Diameter Diameter Diameter of Gasket Diameter Diameter Diameter of Gasket Minimum Diameter Diameter Diameter of Gasket Minimum
Inner Inner Inner
for for PTFE- for for PTFE- Diameter for for PTFE- Diameter
Flat Diameter Flat Flat
Effective Effective Effective Effective Effective Effective
Sealing Sealing Gasket sheathed of Sealing Sealing Gasket sheathed of Sealing Sealing Gasket sheathed of
Gasket Gasket*2 Gasket Gasket*2 Gasket Gasket*2
[øA] [øB] [øC] [øA] [øB] [øC] [øA] [øB] [øC]
[øD] [øD] [øD]
0.1 0.59 1.50 0.67 0.87 0.59 0.59 1.18 0.67 [0.59]*1 0.87 [0.75]*1 0.59 ― ― ― ―
0.2 0.59 1.50 0.67 0.87 0.59 0.59 1.18 0.67 [0.59]*1 0.87 [0.75]*1 0.59 ― ― ― ―
0.4 0.59 1.50 0.67 0.87 0.59 0.59 1.18 0.67 [0.59]*1 0.87 [0.75]*1 0.59 ― ― ― ―
0.5 0.71 1.50 0.87 0.59 0.87 1.34 0.87 0.59 0.59 1.30 0.87 0.59
1.0 1.26 2.13 1.38 1.10 1.39 2.13 1.38 1.14 1.06 1.97 1.38 1.06
1.25 1.46 2.28 1.69 1.34 1.59 2.53 1.69 1.34 ― ― ― ―
1.5 1.76 2.80 1.93 1.61 1.89 2.83 1.93 1.61 1.57 2.68 1.93 1.57
2.0 2.26 3.31 2.40 2.09 2.39 3.50 2.40 2.09 2.05 3.23 2.40 2.05
2.5 2.73 4.06 3.31 2.60 2.84 4.25 3.31 2.60 ― ― ― ―
3.0 3.19 4.49 3.54 3.19 3.33 4.69 3.54 3.19 3.19 4.41 3.54 3.19
4.0 4.19 5.51 4.53 4.02 4.34 5.75 4.53 4.02 3.86 5.28 4.53 3.86
5.0 5.14 6.50 5.55 5.04 5.34 6.81 5.55 5.04 ― ― ― ―
6.0 6.46 7.48 6.57 5.79 6.46 8.23 {8.50}*1 6.57 5.91 5.67 7.40 6.57 5.67
8.0 8.58 9.45 8.58 7.83 8.58 10.20 {10.71}*1 8.58 7.91 7.56 9.45 8.58 7.56
10 ― ― ― ― 10.61 12.60 {13.07}*1 10.63 9.84 ― ― ― ―
12 ― ― ― ― 12.64 14.44 {15.43}*1 12.64 11.85 ― ― ― ―
14 ― ― ― ― 13.76 16.22 14.13 12.99 ― ― ― ―
16 ― ― ― ― 15.78 18.70 16.14 15.00 ― ― ― ―
20 ― ― ― ― 22.87 22.87 <23.86>*1 20.20 18.31 ― ― ― ―
*1: The value varies depending on the selection of process connection code:
DJ1, DJ2, DE4: Values in [ ].
BA2, BJ2, CA2, CJ2, PA2: Values in { }.
BE2, CE2: Values in < >.
Gasket inner diameter*2

Sensor
øB
øD

øC

øA

Lining

or

Flat gasket
PTFE sheathed gasket F23.ai

*2: To prevent the gasket from protruding into the flow path, make sure that this length is smaller than the minimum inner diameter of the gasket in the table.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
34
For high pressure type (ASME Class 600 flange), • Do not install anything in the vicinity that may interfere with
use a flat gasket that matches the outer diameter the magnetic field, induced signal voltages, or flow velocity
and inner diameter of the grounding ring considering distributions of the flowmeter.
• A straight run may not be required on the downstream side of
the dimensions of the seal structure of the flange.
the flowmeter. However, if a downstream valve or other fitting
Do not use a spiral wound gasket. Also, be careful causes irregularity or deviation in flows, provide a distance of
not to damage the flange surface of the sensor 2D to 3D on the downstream side.
by excessive tightening. The structural figure of • The valves shall be mounted on the downstream side so that
grounding ring with flange and the dimensions of deviated flows do not occur in the sensor and to avoid startup
inner and outer diameter of the grounding ring are from an empty condition.
shown below. Note that the grounding ring must be • In case the piping conditions are compounded, install on the
selected for high pressure type. straight pipe section where the upstream part is sufficiently
rectified.
Sensor Flange face

Grounding ring
Maintaining Stable Fluid Conductivity:
Material: Stainless steel 316L Do not install the flowmeter where fluid conductivity
tends to become uneven. If chemicals are fed near
the upstream side of a magnetic flowmeter, they
Details O-Ring may affect the flow-rate’s indications. To avoid this
Material: Fluororubber (FKM) situation, it is recommended that the chemical feed
ports be located on the downstream side of the
flowmeter. If it is unavoidable that chemicals must be
F24.ai fed on the upstream side, provide a sufficient straight
Grounding Rings for High Pressure Type pipe length (approximately 50D or more) to ensure
Unit: mm (approx. in.) the proper mixture of fluids.
Size Outer Diameter Inner Diameter Low Conductivity Fluid:
25 (1) 69 (2.72) 29.0 (1.14)
When used for fluids with high flow noise (pure
water, low viscosity and low conductivity fluid such
40 (1.5) 92 (3.62) 35.4 (1.39)
as alcohols), the output fluctuation increases and
50 (2) 108 (4.25) 46.5 (1.83) the measurement is affected. In that case, using the
80 (3) 147 (5.79) 70.9 (2.79) Magnetic flowmeter CA Series, vortex flowmeter, or
100 (4) 185 (7.28) 93.0 (3.66) Coriolis flowmeter is recommended.
Permeable Fluid:
Noise Avoidance: For use with permeable fluid (e.g. nitric acid,
The flowmeter should be installed away from electrical hydrofluoric acid, high-temperature sodium
motors, transformers, and other power sources in hydroxide, etc.), selecting a model with PFA lining,
order to avoid interference with measurement. vent hole (optional code H), and grounding ring plate
When installing two or more magnetic flowmeters, (thick type)(optional code GRN, GRJ, or GRW), or
provide a distance of at least 5D (D is size of model the Magnetic flowmeter CA Series is recommended.
code) each other. If diameters of them are different, Adhesive Fluid of Insulator:
let D be the larger one. When measuring adhesive fluid of insulator, selecting
Mounting of Flowmeters and Required Straight mirror finished PFA lining or ceramics tube (optional
Pipe Length: code PM or CM), or the Magnetic flowmeter CA
Based on JIS B 7554 “Magnetic Flowmeters” and our Series is recommended. Those help reduce the
piping condition test data, we recommend the piping adhesion on the inner surface of the pipe.
conditions as shown in the following figures. This is Abrasive Slurry Fluid:
not always enough when the piping line incorporates For abrasive slurry fluids mixed with minerals, earth
multiple conditions at the same time. and sand etc., install on vertical piping. This reduces
Gate valve D: Sensor Size uneven wear of the lining. For sizes 200 mm (8 in.)
fully open Tee or less, the AXG magnetic flowmeter with ceramics
tube, the Magnetic flowmeter CA Series, or the AXW
magnetic flowmeter with natural soft rubber lining is
recommended.
5D or more 2D or more 5D or more 0 is allowable.
Reducer 90-degree bend
pipe (*)

0 is allowable. 0 is allowable. 5D or more 0 is allowable.


*: Concentric reducer pipe can be considered part of straight pipe. However,
note that it does not have a rectifying function.
Expander Various valves
pipe

10D or more 2D or more 10D or more 2D or more


F25.ai
Required Straight Pipe Length

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
35
Mounting Positions: Mounting Orientation:
• Pipes must be fully filled with liquids. Install the magnetic flowmeter so that the electrodes
It is essential that pipes remain fully filled at all times, position is not perpendicular to the ground. Otherwise
otherwise flow rate indications may be affected and it may cause the measuring errors because air
measurement errors may be caused. bubbles at upper side or slurry at downside covers
Piping shall be designed so as to maintain the sensor the electrode.
filled with fluids. Mount the terminal box of a remote sensor and the
Vertical mounting is effective in such cases as transmitter of an integral flowmeter above the piping
when fluids tend to separate or solid matter may be to prevent water from entering them.
precipitated. When employing vertical mounting, (Correct)
direct the fluids from the bottom to the top to ensure
(Incorrect) (Incorrect)
that the pipes remain fully filled.
Air bubble

(Correct) (Incorrect)

h
Electrode Electrode Precipitate
Water can
h>0 seep into the
terminal box.
F28.ai

Mounting Orientation
(Correct) (Incorrect)
h Counter Flange Material:
h>0 For some specifications of the wafer type flowmeters
(see the table), if carbon steel flange is used on the
user-side to connect the flowmeter, a measurement
error will be added to the guaranteed accuracy in
this General Specifications. By setting the correction
F26.ai factor provided from us, it is possible to reduce the
added measurement error to around ±0.5%. If you
Mounting Positions want to avoid the measurement error caused by using
• Avoiding Air Bubbles. carbon steel for the user-side flange, select the flange
If air bubbles enter a measurement pipe, flow rate type.
indications may be affected and measurement errors
may be caused. Size 40 mm, 50 mm, 65 mm, 80 mm, 100 mm, 125 mm
In cases where fluids contain air bubbles, piping must Process
A: Wafer Type
be designed to prevent them from accumulating in Connection
the measurement pipe of a sensor. Lining A: PFA Lining
If a valve exists near the sensor, try to mount the * This does not apply to products that include the following
sensor on the valve’s upstream side in order to specifications.
prevent a possible reduction of pressure inside the Gasket for plastic piping (/GA, /GC, /GD)
pipe, thereby avoiding the possibility of air bubbles. Size of 40 mm, 50 mm, 65 mm using grounding ring electrode
(/GRP, /GRT)

(Correct)

(Incorrect)

(Correct) (Incorrect)

Valve F27.ai

Avoiding Air Bubbles

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
36
n MODEL AND SUFFIX CODE
Note:
1: There are some limitations on the combination of specifications. Read specification code table when
selecting specification code.
2: For both wafer and flange type of 2.5 to 10 mm (0.1 to 0.4 in.), prepare 15 mm (0.5 in.) diameter nominal
flanges on the process pipe side. However, for the flanges EN PN40, JIS 10K, JIS 20K, types for the nominal
diameter 10 mm (0.4 in.) flange can also be selected (Process Connection Code DE4, DJ1, and DJ2).
The process connection of ceramics tube sizes 2.5 to 10 mm (0.1 to 0.4 in.) is only Union Joint (Screw and
Welding type).
3: For EN standard wafer and flange type of sizes 2.5 to 50 mm (0.1 to 2 in.), select PN40 even for lower
pressure rating because the dimensions of mating faces for PN10, 16, and 40 are the same.
For EN standard wafer and flange type of sizes 65 to 150 mm (2.5 to 6 in.), select PN16 even for lower
pressure rating because the dimensions of mating faces for PN10 and 16 are the same.
4: The dimensions of mating faces are based on the following flange standards.
JIS F12: JIS G 3443-2, JIS 10K, 20K: JIS B 2220 and JIS G 3443-2,
ASME: ASME B 16.5, EN: EN 1092-1, JPI: JPI-7S-15, AS: AS2129
Each flange standard has the specifications for the limitation on the available fluid temperature and pressure
as well as the dimensions. Be sure that user's fluid conditions meet the specifications of each flange
standard when selecting a process connection code.
5: The grounding device is selectable from none, grounding ring, or built-in grounding electrode. When
selecting the grounding ring or the built-in grounding electrode, it is also necessary to select its type (material
etc.) from the optional codes.
6: The lay length (face to face) of the flange type of PFA lining sizes 15 to 400 mm (0.5 to 16 in.) conforms
to ISO standard (ISO 20456) except for ASME Class 600 flange high pressure type. The lay length for
ceramics tube (wafer and union joint) and Hygienic are the same as those of the conventional model
ADMAG AXF series (AXF standard lay length). The lay length depends on the presence or absence of the
optional grounding rings or gaskets, so see the Dimensional Drawings.
7: Lining, electrode, pipe connection adapter (for Hygienic, or Hygienic Explosion Protection), and
grounding device (grounding ring plate, metal hat grounding ring, grounding ring electrode, built-in grounding
electrode) are wetted parts.
Users must consider the characteristics of selected wetted parts material and influence of process fluids.
The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to
personnel and/or damage to plant facilities. It is also possible that the instrument itself can be damaged and
that fragments from the instrument can contaminate the user's process fluids. Be very careful with highly
corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and
high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted
parts material.
8: In the case of remote sensor, select "None (or Without)" for each specification code of "Power Supply",
"Communication and I/O", "Transmitter Wiring Terminal" and "Display".
9: Select appropriate equipment in accordance with the laws and regulations of the relevant country/region,
when it is used in a location where explosive atmospheres may be present.
In the case that final destination is Taiwan or UAE and the explosion type is required, select IECEx explosion
protection type.
10: Wafer type replacement model has the lay length compatible with previous models (ADMAG, YEWMAG
series) by attaching grounding rings for wafer type replacement model(optional code GAN) to integral flow
meter or remote sensor. For details on dimensions, please refer to the DIMENSIONAL DRAWINGS.
11: For wafer types with sizes ranging from 2.5 to 15 mm, the lay length of previous models (ADMAG and
YEWMAG series) is the same as when grounding rings with optional codes GRN, GRP, and GRT
are selected for the AXG standard lay length type. For details on dimensions, please refer to the the
DIMENSIONAL DRAWINGS.
12: In China, when using magnetic flowmeters for pressure piping, the optional code /TS1 or /TS2 must be
selected . When placing an order, please confirm the grade of the pressure piping (either GC1 or GC2) and
select the optional code /TS1 or /TS2.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
37
●General-purpose, Submersible, Explosionprotection, Wafer, Flange, PFA Lining (2.5 to 400 mm/0.1 to 16 in.)

Model Suffix Code Description Limitation


AXG002 Magnetic Flowmeter (2.5 mm/0.1 in)
AXG005 Magnetic Flowmeter (5 mm/0.2 in)
AXG010 Magnetic Flowmeter (10 mm/0.4 in)
AXG015 Magnetic Flowmeter (15 mm/0.5 in)
AXG025 Magnetic Flowmeter (25 mm/1 in)
AXG032 Magnetic Flowmeter (32 mm/1.25 in)
AXG040 Magnetic Flowmeter (40 mm/1.5 in)
AXG050 Magnetic Flowmeter (50 mm/2 in)
AXG065 Magnetic Flowmeter (65 mm/2.5 in)
AXG080 Magnetic Flowmeter (80 mm/3 in)
AXG100 Magnetic Flowmeter (100 mm/4 in)
AXG125 Magnetic Flowmeter (125 mm/5 in)
AXG150 Magnetic Flowmeter (150 mm/6 in)
AXG200 Magnetic Flowmeter (200 mm/8 in)
AXG250 Magnetic Flowmeter (250 mm/10 in)
AXG300 Magnetic Flowmeter (300 mm/12 in)
AXG350 Magnetic Flowmeter (350 mm/14 in)
AXG400 Magnetic Flowmeter (400 mm/16 in)
-G General-purpose
-C Explosion protection
Use
15 to 400 mm (0.5 to 16 in.),
-W Submersible
only for Remote sensor
A Integral Flowmeter
D Remote Sensor (for AXFA11)
Construction
E Remote Sensor (for AXG1A)
G Remote Sensor (for AXG4A)
000 Non Explosion Protection Approval
See Restriction for
KF2 ATEX Flameproof
Explosion Protection type
See Restriction for
KJ2 ATEX Flameproof with Intrinsically Safe output
Explosion Protection type
ATEX Flameproof with Intrinsically Safe output for See Restriction for
KT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
SF2 IECEx Flameproof
Explosion Protection type
See Restriction for
SJ2 IECEx Flameproof with Intrinsically Safe output
Explosion Protection type
IECEx Flameproof with Intrinsically Safe output for See Restriction for
ST2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
FF2 FM Flameproof
Explosion Protection type
See Restriction for
Explosion FJ2 FM Flameproof with Intrinsically Safe output
Explosion Protection type
Protection
FM Flameproof with Intrinsically Safe output for See Restriction for
FT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
CF2 FMc Flameproof (Canada)
Explosion Protection type
FMc Flameproof with Intrinsically Safe output See Restriction for
CJ2
(Canada) Explosion Protection type
FMc Flameproof with Intrinsically Safe output for See Restriction for
CT2
FOUNDATION Fieldbus, PROFIBUS PA (Canada) Explosion Protection type
See Restriction for
GF2 EAC Flameproof
Explosion Protection type
See Restriction for
GJ2 EAC Flameproof with Intrinsically Safe output
Explosion Protection type
EAC Flameproof with Intrinsically Safe output for See Restriction for
GT2
FOUNDATION Fieldbus Explosion Protection type
See Restriction for
JF5 Japan Flameproof
Explosion Protection type

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
38
(Continued)
See Restriction for
NF2 NEPSI Flameproof
Explosion Protection type
See Restriction for
NJ2 NEPSI Flameproof with Intrinsically Safe output
Explosion Explosion Protection type
Protection See Restriction for
PF2 Korea Flameproof
Explosion Protection type
See Restriction for
UF2 INMETRO Flameproof (Brazil)
Explosion Protection type
AA1 ASME Class 150 Wafer 2.5 to 200 mm (0.1 to 8 in.)
AA2 ASME Class 300 Wafer 2.5 to 200 mm (0.1 to 8 in.)
AE1 EN PN10 Wafer 200 mm (8 in.)
AE2 EN PN16 Wafer 65 to 200 mm (2.5 to 8 in.)
AE4 EN PN40 Wafer 2.5 to 50 mm (0.1 to 2 in.)
Wafer AG1 JIS F12 Wafer 80 to 200 mm (3 to 8 in.)
AJ1 JIS 10K Wafer 2.5 to 200 mm (0.1 to 8 in.)
AJ2 JIS 20K Wafer 2.5 to 200 mm (0.1 to 8 in.)
2.5 to 200 mm (0.1 to 8 in.)
(32, 65, and 125 mm (1.25,
AP1 JPI Class 150 Wafer
2.5, and 5 in.) are not
available.)
BA1 ASME Class 150 Flange
BA2 ASME Class 300 Flange 2.5 to 300 mm (0.1 to 12 in.)
BE1 EN PN10 Flange 200 to 400 mm (8 to 16 in.)
BE2 EN PN16 Flange 65 to 300 mm (2.5 to 12 in.)
BE3 EN PN25 Flange 80 to 400 mm (3 to 16 in.)
BE4 EN PN40 Flange 2.5 to 50 mm (0.1 to 2 in.)
Stainless
BG1 JIS F12 Flange 80 to 400 mm (3 to 16 in.)
Steel
Flange BJ1 JIS 10K Flange
(F304) BJ2 JIS 20K Flange 2.5 to 300 mm (0.1 to 12 in.)
32, 65, and 125 mm (1.25,
BP1 JPI Class 150 Flange 2.5, and 5 in.) are not
available.
DE4 EN PN40 Flange (Nominal Diameter 10 mm) 2.5 to 10 mm (0.1 to 0.4 in.)
Process DJ1 JIS 10K Flange (Nominal Diameter 10 mm) 2.5 to 10 mm (0.1 to 0.4 in.)
Connection DJ2 JIS 20K Flange (Nominal Diameter 10 mm) 2.5 to 10 mm (0.1 to 0.4 in.)
32, 65, and 125 mm (1.25,
PA1 ASME Class 150 Flange 2.5, and 5 in.) are not
available.
2.5 to 300 mm (0.1 to 12
in.) (32, 65, and 125 mm
PA2 ASME Class 300 Flange
(1.25, 2.5, and 5 in.) are not
available.)
Stainless PE1 EN PN10 Flange 200 to 400 mm (8 to 16 in.)
Steel 80 to 300 mm (3 to 12
Flange PE2 EN PN16 Flange in.) (125 mm (5 in.) is not
(F316) available.)
PE3 EN PN25 Flange 80 to 400 mm (3 to 16 in.)
2.5 to 50 mm (0.1 to 2 in.)
PE4 EN PN40 Flange (32 mm (1.25 in.) is not
available.)
32, 65, and 125 mm (1.25,
PJ1 JIS 10K Flange 2.5, and 5 in.) are not
available.
CA1 ASME Class 150 Flange 50 to 400 mm (2 to 16 in.)
CA2 ASME Class 300 Flange 50 to 300 mm (2 to 12 in.)
CE1 EN PN10 Flange 200 to 400 mm (8 to 16 in.)
Carbon CE2 EN PN16 Flange 65 to 300 mm (2.5 to 12 in.)
Steel
Flange CE4 EN PN40 Flange 50 mm (2 in.)
CG1 JIS F12 Flange 80 to 400 mm (3 to 16 in.)
CJ1 JIS 10K Flange 50 to 400 mm (2 to 16 in.)
CJ2 JIS 20K Flange 50 to 300 mm (2 to 12 in.)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
39
(Continued)
50 to 400 mm (2 to 16 in.)
CS1 AS Table D Flange (65, and 125 mm (2.5, and
Carbon 5 in.) are not available.)
Process
Steel
Connection 50 to 300 mm (2 to 12 in.)
Flange
CS2 AS Table E Flange (65, and 125 mm (2.5, and
5 in.) are not available.)
Lining A PFA Lining
L Stainless Steel 316L
P Platinum-Iridium
H Nickel Alloy
Electrode T Tantalum
V Titanium
2.5 mm, 5 mm, 10 mm (0.1,
W Tungsten Carbide
0.2, 0.4 in.) are not available
1 None
Grounding Device 2 Grounding Rings Select an optional code
3 Built-in Grounding Electrodes Select an optional code
1 Standard Material with Standard Coating
Housing and Coating Not applicable for
2 Standard Material with Rugged Coating
Submersible
See Restriction for
0 JIS G1/2 Female
Explosion Protection type
Not applicable for
Submersible, See
2 ASME 1/2 NPT Female
Restriction for Explosion
Cable Entry
Protection type
Not applicable for
Submersible, See
4 ISO M20×1.5 Female
Restriction for Explosion
Protection type
B Standard
Accuracy
C High Grade 25 to 200 mm (1 to 8 in.)
-1 100-240 V AC / 100-120 V DC Only for Integral Flowmeter
Power Supply -2 24 V AC / DC Only for Integral Flowmeter
-N None (Remote Sensor) Only for Remote Sensor
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
D# Only for Integral Flowmeter
BRAIN and I/O (Type A to K, P to T). See "Details".
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
J# Only for Integral Flowmeter
HART 7 and I/O (Type A to K, P to T). See "Details".
#: 0, 2, 6
M# Only for Integral Flowmeter
Modbus and I/O (Type 0, 2, 6). See "Details".
Communication and I/O F0 FOUNDATION Fieldbus I/O Only for Integral Flowmeter
G0 PROFIBUS PA I/O Only for Integral Flowmeter
Only for Integral Flowmeter
Only for Transmitter Wiring
P0 EtherNet/IP
Terminal: 1
Only for Display: 3 or N
NN None (Remote Sensor) Only for Remote Sensor
1 M4 Screw-type
Transmitter Wiring Terminal 2 Clamp Type
N None (Remote Sensor) Only for Remote Sensor
1 With Display (English, Multi-language) Only for Integral Flowmeter
2 With Display (English, Chinese) Only for Integral Flowmeter
Display Only for Integral Flowmeter
3 With Display (English) Only for Communication
and I/O: P0
N Without Display/Remote Sensor
Optional Specification /# Refer to optional specification table.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
40
●General-purpose, Submersible, Flange, PFA Lining (500 mm/20 in.)

Model Suffix Code Description Limitation


AXG500 Magnetic Flowmeter (500 mm/20 in)
-G General-purpose
Use
-W Submersible
D Remote Sensor (for AXFA11)
Construction
E Remote Sensor (for AXG1A)
Explosion
000 Non Explosion Protection Approval
Protection
Stainless BA1 ASME Class 150 Flange
Steel BE1 EN PN10 Flange
Flange
Process (F304) BE2 EN PN16 Flange
Connection
Carbon CA1 ASME Class 150 Flange
Steel CE1 EN PN10 Flange
Flange CE2 EN PN16 Flange
Lining A PFA Lining
L Stainless Steel 316L
Electrode
H Nickel Alloy
1 None
Grounding Device
2 Grounding Rings Select an optional code
1 Standard Material with Standard Coating
Housing and Coating Not applicable for
2 Standard Material with Rugged Coating
Submersible
0 JIS G1/2 Female
Not applicable for
2 ASME 1/2 NPT Female
Cable Entry Submersible
Not applicable for
4 ISO M20×1.5 Female
Submersible
Accuracy B Standard
Power Supply -N None
Communication and I/O NN None
Transmitter Wiring Terminal N None
Display N Remote Sensor
Optional Specification /# Refer to optional specification table.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
41
●General-purpose, Submersible, Explosionprotection, Flange, PFA Lining (High Pressure Type, ASME Class 600)

Model Suffix Code Description Limitation


AXG025 Magnetic Flowmeter (25 mm/1 in)
AXG040 Magnetic Flowmeter (40 mm/1.5 in)
AXG050 Magnetic Flowmeter (50 mm/2 in)
AXG080 Magnetic Flowmeter (80 mm/3 in)
AXG100 Magnetic Flowmeter (100 mm/4 in)
-G General-purpose
Use -C Explosion protection
-W Submersible
A Integral Flowmeter
D Remote Sensor (for AXFA11)
Construction
E Remote Sensor (for AXG1A)
G Remote Sensor (for AXG4A)
000 Non Explosion Protection Approval
See Restriction for
SF2 IECEx Flameproof
Explosion Protection type
See Restriction for
SJ2 IECEx Flameproof with Intrinsically Safe output
Explosion Protection type
IECEx Flameproof with Intrinsically Safe output for See Restriction for
ST2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
FF2 FM Flameproof
Explosion Protection type
See Restriction for
FJ2 FM Flameproof with Intrinsically Safe output
Explosion Protection type
FM Flameproof with Intrinsically Safe output for See Restriction for
FT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
Explosion
Protection See Restriction for
GF2 EAC Flameproof
Explosion Protection type
See Restriction for
GJ2 EAC Flameproof with Intrinsically Safe output
Explosion Protection type
EAC Flameproof with Intrinsically Safe output for See Restriction for
GT2
FOUNDATION Fieldbus Explosion Protection type
See Restriction for
NF2 NEPSI Flameproof
Explosion Protection type
See Restriction for
NJ2 NEPSI Flameproof with Intrinsically Safe output
Explosion Protection type
See Restriction for
PF2 Korea Flameproof
Explosion Protection type
See Restriction for
UF2 INMETRO Flameproof (Brazil)
Explosion Protection type
Stainless
Process Steel
EA4 ASME Class 600 Flange (High Pressure)
Connection Flange
(F304)
Lining A PFA Lining
Electrode L Stainless Steel 316L
Grounding device 2 Grounding Rings Select an optional code
1 Standard Material with Standard Coating
Housing and Coating Not applicable for
2 Standard Material with Rugged Coating
Submersible
See Restriction for
0 JIS G1/2 Female
Explosion Protection type
Not applicable for
Submersible, See
2 ASME 1/2 NPT Female
Restriction for Explosion
Cable Entry
Protection type
Not applicable for
Submersible, See
4 ISO M20×1.5 Female
Restriction for Explosion
Protection type
Accuracy B Standard

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
42
(Continued)
-1 100-240 V AC / 100-120 V DC Only for Integral Flowmeter
Power Supply -2 24 V AC / DC Only for Integral Flowmeter
-N None (Remote Sensor) Only for Remote Sensor
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
D# Only for Integral Flowmeter
BRAIN and I/O (Type A to K, P to T). See "Details".
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
J# Only for Integral Flowmeter
HART 7 and I/O (Type A to K, P to T). See "Details".
#: 0, 2, 6
M# Only for Integral Flowmeter
Modbus and I/O (Type 0, 2, 6). See "Details".
Communication and I/O F0 FOUNDATION Fieldbus I/O Only for Integral Flowmeter
G0 PROFIBUS PA I/O Only for Integral Flowmeter
Only for Integral Flowmeter
Only for Transmitter Wiring
P0 EtherNet/IP
Terminal: 1
Only for Display: 3 or N
NN None (Remote Sensor) Only for Remote Sensor
1 M4 Screw-type
Transmitter Wiring Terminal 2 Clamp Type
N None (Remote Sensor) Only for Remote Sensor
1 With Display (English, Multi-language) Only for Integral Flowmeter
2 With Display (English, Chinese) Only for Integral Flowmeter
Display Only for Integral Flowmeter
3 With Display (English) Only for Communication
and I/O: P0
N Without Display/Remote Sensor
Optional Specification /# Refer to optional specification table.

●General-purpose, Explosionprotection, Ceramics Tube

Model Suffix Code Description Limitation


AXG002 Magnetic Flowmeter (2.5 mm/0.1 in)
AXG005 Magnetic Flowmeter (5 mm/0.2 in)
AXG010 Magnetic Flowmeter (10 mm/0.4 in)
AXG015 Magnetic Flowmeter (15 mm/0.5 in)
AXG025 Magnetic Flowmeter (25 mm/1 in)
AXG040 Magnetic Flowmeter (40 mm/1.5 in)
AXG050 Magnetic Flowmeter (50 mm/2 in)
AXG080 Magnetic Flowmeter (80 mm/3 in)
AXG100 Magnetic Flowmeter (100 mm/4 in)
AXG150 Magnetic Flowmeter (150 mm/6 in)
AXG200 Magnetic Flowmeter (200 mm/8 in)
-G General-purpose
Use
-C Explosion protection
A Integral Flowmeter
D Remote Sensor (for AXFA11)
Construction
E Remote Sensor (for AXG1A)
G Remote Sensor (for AXG4A)
000 Non Explosion Protection Approval
See Restriction for
KF2 ATEX Flameproof
Explosion Protection type
See Restriction for
KJ2 ATEX Flameproof with Intrinsically Safe output
Explosion Protection type
ATEX Flameproof with Intrinsically Safe output for See Restriction for
KT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
Explosion
Protection See Restriction for
SF2 IECEx Flameproof
Explosion Protection type
See Restriction for
SJ2 IECEx Flameproof with Intrinsically Safe output
Explosion Protection type
IECEx Flameproof with Intrinsically Safe output for See Restriction for
ST2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
FF2 FM Flameproof
Explosion Protection type

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
43
(Continued)
See Restriction for
FJ2 FM Flameproof with Intrinsically Safe output
Explosion Protection type
FM Flameproof with Intrinsically Safe output for See Restriction for
FT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
GF2 EAC Flameproof
Explosion Protection type
See Restriction for
GJ2 EAC Flameproof with Intrinsically Safe output
Explosion Protection type
EAC Flameproof with Intrinsically Safe output for See Restriction for
GT2
Explosion FOUNDATION Fieldbus Explosion Protection type
Protection See Restriction for
JF5 Japan Flameproof
Explosion Protection type
See Restriction for
NF2 NEPSI Flameproof
Explosion Protection type
See Restriction for
NJ2 NEPSI Flameproof with Intrinsically Safe output
Explosion Protection type
See Restriction for
PF2 Korea Flameproof
Explosion Protection type
See Restriction for
UF2 INMETRO Flameproof (Brazil)
Explosion Protection type
15 to 200 mm (0.5 to 8 in.)
AA1 ASME Class 150 Wafer (125 mm (5 in.) is not
available.)
15 to 200 mm (0.5 to 8 in.)
AA2 ASME Class 300 Wafer (125 mm (5 in.) is not
available.)
AE1 EN PN10 Wafer 200 mm (8 in.)
80 to 200 mm (3 to 8 in.)
AE2 EN PN16 Wafer (125 mm (5 in.) is not
available.)
Wafer
AE4 EN PN40 Wafer 15 to 50 mm (0.5 to 2 in.)
80 to 200 mm (3 to 8 in.)
AG1 JIS F12 Wafer (125 mm (5 in.) is not
Process
available.)
Connection
15 to 200 mm (0.5 to 8 in.)
AJ1 JIS 10K Wafer (125 mm (5 in.) is not
available.)
15 to 200 mm (0.5 to 8 in.)
AJ2 JIS 20K Wafer (125 mm (5 in.) is not
available.)
2.5 to 5 mm (0.1 to 0.2 in.):
Union GUN Screw Union Joint 1/4 NPT
Joint 10 mm (0.4 in.): 3/8 NPT
Stainless 2.5 to 5 mm (0.1 to 0.2 in.):
Steel GUR Screw Union Joint R 1/4
(F316) 10 mm (0.4 in.): R 3/8
GUW Welding Union Joint 2.5 to 10 mm (0.1 to 0.4 in.)
Lining C Ceramics Tube
Erectrode E Platinum-alumina Cermet
1 None
Grounding Device 2.5 mm, 5 mm, 10 mm (0.1,
2 Grounding Rings 0.2, 0.4 in.) are not available
Select an optional code
1 Standard Material with Standard Coating
Housing and Coating
2 Standard Material with Rugged Coating
See Restriction for
0 JIS G1/2 Female
Explosion Protection type
See Restriction for
Cable Entry 2 ASME 1/2 NPT Female
Explosion Protection type
See Restriction for
4 ISO M20×1.5 Female
Explosion Protection type
B Standard
Accuracy
C High Grade 25 to 200 mm (1 to 8 in.)
-1 100-240 V AC / 100-120 V DC Only for Integral Flowmeter
Power Supply -2 24 V AC / DC Only for Integral Flowmeter
-N None (Remote Sensor) Only for Remote Sensor

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
44
(Continued)
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
D# Only for Integral Flowmeter
BRAIN and I/O (Type A to K, P to T). See "Details".
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
J# Only for Integral Flowmeter
HART 7 and I/O (Type A to K, P to T). See "Details".
#: 0, 2, 6
M# Only for Integral Flowmeter
Modbus and I/O (Type 0, 2, 6). See "Details".
Communication and I/O F0 FOUNDATION Fieldbus I/O Only for Integral Flowmeter
G0 PROFIBUS PA I/O Only for Integral Flowmeter
Only for Integral Flowmeter
Only for Transmitter Wiring
P0 EtherNet/IP
Terminal: 1
Only for Display: 3 or N
NN None (Remote Sensor) Only for Remote Sensor
1 M4 Screw-type
Transmitter Wiring Terminal 2 Clamp Type
N None (Remote Sensor) Only for Remote Sensor
1 With Display (English, Multi-language) Only for Integral Flowmeter
2 With Display (English, Chinese) Only for Integral Flowmeter
Display Only for Integral Flowmeter
3 With Display (English) Only for Communication
and I/O: P0
N Without Display/Remote Sensor
Optional Specification /# Refer to optional specification table.

●Hygienic, Hygienic Explosion protection, PFA Lining

Model Suffix Code Description Limitation


AXG015 Magnetic Flowmeter (15 mm/0.5 in)
AXG025 Magnetic Flowmeter (25 mm/1 in)
AXG032 Magnetic Flowmeter (32 mm/1.25 in)
AXG040 Magnetic Flowmeter (40 mm/1.5 in)
AXG050 Magnetic Flowmeter (50 mm/2 in)
AXG065 Magnetic Flowmeter (65 mm/2.5 in)
AXG080 Magnetic Flowmeter (80 mm/3 in)
AXG100 Magnetic Flowmeter (100 mm/4 in)
AXG125 Magnetic Flowmeter (125 mm/5 in)
-H Hygienic
Use
-J Hygienic Explosion Protection
A Integral Flowmeter
D Remote Sensor (for AXFA11)
Construction
E Remote Sensor (for AXG1A)
G Remote Sensor (for AXG4A)
000 Non Explosion Protection Approval
See Restriction for
KF2 ATEX Flameproof
Explosion Protection type
See Restriction for
KJ2 ATEX Flameproof with Intrinsically Safe output
Explosion Protection type
ATEX Flameproof with Intrinsically Safe output for See Restriction for
KT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
SF2 IECEx Flameproof
Explosion Protection type
See Restriction for
Explosion SJ2 IECEx Flameproof with Intrinsically Safe output
Explosion Protection type
Protection
IECEx Flameproof with Intrinsically Safe output for See Restriction for
ST2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
FF2 FM Flameproof
Explosion Protection type
See Restriction for
FJ2 FM Flameproof with Intrinsically Safe output
Explosion Protection type
FM Flameproof with Intrinsically Safe output for See Restriction for
FT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
CF2 FMc Flameproof (Canada)
Explosion Protection type

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
45
(Continued)
FMc Flameproof with Intrinsically Safe output See Restriction for
CJ2
(Canada) Explosion Protection type
FMc Flameproof with Intrinsically Safe output for See Restriction for
CT2
FOUNDATION Fieldbus, PROFIBUS PA (Canada) Explosion Protection type
See Restriction for
GF2 EAC Flameproof
Explosion Protection type
See Restriction for
GJ2 EAC Flameproof with Intrinsically Safe output
Explosion Protection type
EAC Flameproof with Intrinsically Safe output for See Restriction for
GT2
Explosion FOUNDATION Fieldbus Explosion Protection type
Protection See Restriction for
JF5 Japan Flameproof
Explosion Protection type
See Restriction for
NF2 NEPSI Flameproof
Explosion Protection type
See Restriction for
NJ2 NEPSI Flameproof with Intrinsically Safe output
Explosion Protection type
See Restriction for
PF2 Korea Flameproof
Explosion Protection type
See Restriction for
UF2 INMETRO Flameproof (Brazil)
Explosion Protection type
15 to 100 mm (0.5 to 4 in.)
HAB Tri-Clamp, Stainless Steel F316L (32 mm (1.25 in.) is not
available.)
HDB DIN 32676 Clamp, Stainless Steel F316L
ISO 2852 Clamp (for JIS G3447 Piping),
Clamp HJA
Stainless Steel F304
ISO 2852 Clamp (for JIS G3447 Piping),
HJB
Stainless Steel F316L
ISO 2852 / SMS 3016 Clamp,
Process HKB
Stainless Steel F316L
Connection
JDB DIN 11851 Union, Stainless Steel F316L
ISO 2853 Union (for JIS G3447 Piping),
JJA 25 to 100 mm (1 to 4 in.)
Stainless Steel F304
ISO 2853 Union (for JIS G3447 Piping),
JJB 25 to 100 mm (1 to 4 in.)
Union Stainless Steel F316L
ISO 2853 Union,
JKB 15 to 100 mm (0.5 to 4 in.)
Stainless Steel F316L
SMS 1145 Union (Open groove packing type),
JSB 25 to 100 mm (1 to 4 in.)
Stainless Steel F316L
DIN 11850 Piping Butt Weld Joint,
KDB
Stainless Steel F316L
JIS G3447 Piping Butt Weld Joint,
Butt KJA
Process Stainless Steel F304
Weld
Connection JIS G3447 Piping Butt Weld Joint,
Joint KJB
Stainless Steel F316L
ISO 2037 Piping Butt Weld Joint,
KKB
Stainless Steel F316L
Lining A PFA Lining
Erectrode L Stainless Steel 316L
Grouding Device 1 None
Housing and Coating 1 Standard Material with Standard Coating
See Restriction for
0 JIS G1/2 Female
Explosion Protection type
See Restriction for
Cable Entry 2 ASME 1/2 NPT Female
Explosion Protection type
See Restriction for
4 ISO M20×1.5 Female
Explosion Protection type
B Standard
Accuracy
C High Grade 25 to 125 mm (1 to 5 in.)
-1 100-240 V AC / 100-120 V DC Only for Integral Flowmeter
Power Supply -2 24 V AC / DC Only for Integral Flowmeter
-N None (Remote Sensor) Only for Remote Sensor

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
46
(Continued)
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
D# Only for Integral Flowmeter
BRAIN and I/O (Type A to K, P to T). See "Details".
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
J# Only for Integral Flowmeter
HART 7 and I/O (Type A to K, P to T). See "Details".
#: 0, 2, 6
M# Only for Integral Flowmeter
Modbus and I/O (Type 0, 2, 6). See "Details".
Communication and I/O F0 FOUNDATION Fieldbus I/O Only for Integral Flowmeter
G0 PROFIBUS PA I/O Only for Integral Flowmeter
Only for Integral Flowmeter
Only for Transmitter Wiring
P0 EtherNet/IP
Terminal: 1
Only for Display code: 3 or N
NN None (Remote Sensor) Only for Remote Sensor
1 M4 Screw-type
Transmitter Wiring Terminal 2 Clamp Type
N None (Remote Sensor) Only for Remote Sensor
1 With Display (English, Multi-language) Only for Integral Flowmeter
2 With Display (English, Chinese) Only for Integral Flowmeter
Display Only for Integral Flowmeter
3 With Display (English) Only for Communication
and I/O: P0
N Without Display/Remote Sensor
Optional Specification /# Refer to optional specification table.

●Replacement Model, General-purpose, Submersible, Explosionprotection, Wafer, PFA Lining

Model Suffix Code Description Limitation


AXG025 Magnetic Flowmeter (25 mm/1 in)
AXG040 Magnetic Flowmeter (40 mm/1.5 in)
AXG050 Magnetic Flowmeter (50 mm/2 in)
AXG080 Magnetic Flowmeter (80 mm/3 in)
AXG100 Magnetic Flowmeter (100 mm/4 in)
AXG150 Magnetic Flowmeter (150 mm/6 in)
AXG200 Magnetic Flowmeter (200 mm/8 in)
-G General-purpose
-C Explosion protection
Use
25 to 200 mm (1 to 8 in.),
-W Submersible
only for Remote sensor
A Integral Flowmeter
Construction E Remote Sensor (for AXG1A)
G Remote Sensor (for AXG4A)
000 Non Explosion Protection Approval
See Restriction for
SF2 IECEx Flameproof
Explosion Protection type
See Restriction for
SJ2 IECEx Flameproof with Intrinsically Safe output
Explosion Protection type
IECEx Flameproof with Intrinsically Safe output for See Restriction for
ST2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
FF2 FM Flameproof
Explosion Protection type
See Restriction for
Explosion FJ2 FM Flameproof with Intrinsically Safe output
Explosion Protection type
Protection
FM Flameproof with Intrinsically Safe output for See Restriction for
FT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
JF5 Japan Flameproof
Explosion Protection type
See Restriction for
NF2 NEPSI Flameproof
Explosion Protection type
See Restriction for
NJ2 NEPSI Flameproof with Intrinsically Safe output
Explosion Protection type
See Restriction for
PF2 Korea Flameproof
Explosion Protection type

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
47
(Continued)
Explosion See Restriction for
UF2 INMETRO Flameproof (Brazil)
Protection Explosion Protection type
AA1 ASME Class 150 Wafer 25 to 200 mm (1 to 8 in.)
AA2 ASME Class 300 Wafer 25 to 200 mm (1 to 8 in.)
Process
Wafer AG1 JIS F12 Wafer 80 to 200 mm (3 to 8 in.)
Connection
AJ1 JIS 10K Wafer 25 to 200 mm (1 to 8 in.)
AJ2 JIS 20K Wafer 25 to 200 mm (1 to 8 in.)
Lining A PFA Lining
L Stainless Steel 316L
P Platinum-Iridium
H Nickel Alloy
Electrode
T Tantalum
V Titanium
W Tungsten Carbide
Select an optional code /
Grounding Device 2 Grounding Rings
GAN
1 Standard Material with Standard Coating
Housing and Coating Not applicable for
2 Standard Material with Rugged Coating
Submersible
See Restriction for
0 JIS G1/2 Female
Explosion Protection type
Not applicable for
Submersible, See
2 ASME 1/2 NPT Female
Restriction for Explosion
Cable Entry
Protection type
Not applicable for
Submersible, See
4 ISO M20×1.5 Female
Restriction for Explosion
Protection type
Accuracy B Standard
-1 100-240 V AC / 100-120 V DC Only for Integral Flowmeter
Power Supply -2 24 V AC / DC Only for Integral Flowmeter
-N None (Remote Sensor) Only for Remote Sensor
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
D# Only for Integral Flowmeter
BRAIN and I/O (Type A to K, P to T). See "Details".
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
J# Only for Integral Flowmeter
HART 7 and I/O (Type A to K, P to T). See "Details".
#: 0, 2, 6
M# Only for Integral Flowmeter
Modbus and I/O (Type 0, 2, 6). See "Details".
Communication and I/O F0 FOUNDATION Fieldbus I/O Only for Integral Flowmeter
G0 PROFIBUS PA I/O Only for Integral Flowmeter
Only for Integral Flowmeter
Only for Transmitter Wiring
P0 EtherNet/IP
Terminal: 1
Only for Display: 3 or N
NN None (Remote Sensor) Only for Remote Sensor
1 M4 Screw-type
Transmitter Wiring Terminal 2 Clamp Type
N None (Remote Sensor) Only for Remote Sensor
1 With Display (English, Multi-language) Only for Integral Flowmeter
2 With Display (English, Chinese) Only for Integral Flowmeter
Display Only for Integral Flowmeter
3 With Display (English) Only for Communication
and I/O: P0
N Without Display/Remote Sensor
/RW/GAN With Grounding Rings For Wafer Type Mandatory for Wafer Type
Optional Specification Replacement Model Replacement Model
/# Refer to optional specification table.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
48
●General-purpose, Explosion protection. Remote Transmitter

Model Suffix Code Description Limitation


AXG4A Magnetic Flowmeter Remote Transmitter
-G General-purpose
Use
-C Explosion Protection
000 Non Explosion Protection Approval
See Restriction for
KF2 ATEX Flameproof
Explosion Protection type
See Restriction for
KJ2 ATEX Flameproof with Intrinsically Safe output
Explosion Protection type
ATEX Flameproof with Intrinsically Safe output for See Restriction for
KT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
SF2 IECEx Flameproof
Explosion Protection type
See Restriction for
SJ2 IECEx Flameproof with Intrinsically Safe output
Explosion Protection type
IECEx Flameproof with Intrinsically Safe output for See Restriction for
ST2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
FF2 FM Flameproof
Explosion Protection type
See Restriction for
FJ2 FM Flameproof with Intrinsically Safe output
Explosion Protection type
FM Flameproof with Intrinsically Safe output for See Restriction for
FT2
FOUNDATION Fieldbus, PROFIBUS PA Explosion Protection type
See Restriction for
Explosion CF2 FMc Flameproof (Canada)
Explosion Protection type
Protection
FMc Flameproof with Intrinsically Safe output See Restriction for
CJ2
(Canada) Explosion Protection type
FMc Flameproof with Intrinsically Safe output for See Restriction for
CT2
FOUNDATION Fieldbus, PROFIBUS PA (Canada) Explosion Protection type
See Restriction for
GF2 EAC Flameproof
Explosion Protection type
See Restriction for
GJ2 EAC Flameproof with Intrinsically Safe output
Explosion Protection type
EAC Flameproof with Intrinsically Safe output for See Restriction for
GT2
FOUNDATION Fieldbus Explosion Protection type
See Restriction for
JF5 Japan Flameproof
Explosion Protection type
See Restriction for
NF2 NEPSI Flameproof
Explosion Protection type
See Restriction for
NJ2 NEPSI Flameproof with Intrinsically Safe output
Explosion Protection type
See Restriction for
PF2 Korea Flameproof
Explosion Protection type
See Restriction for
UF2 INMETRO Flameproof (Brazil)
Explosion Protection type
Housing and 1 Standard Material with Standard Coating
Coating 2 Standard Material with Rugged Coating
See Restriction for
0 JIS G1/2 Female
Explosion Protection type
See Restriction for
Cable Entry 2 ASME 1/2 NPT Female
Explosion Protection type
See Restriction for
4 ISO M20×1.5 Female
Explosion Protection type
1 100-240 V AC / 100-120 V DC
Power Supply
2 24 V AC / DC
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
D#
BRAIN and I/O (Type A to K, P to T). See "Details".
#: A, B, C, D, E, F, G, H, J, K, P, Q, R, S, T
J#
HART 7 and I/O (Type A to K, P to T). See "Details".
#: 0, 2, 6
M#
Communication and I/O Modbus and I/O (Type 0, 2, 6). See "Details".
F0 FOUNDATION Fieldbus I/O
G0 PROFIBUS PA I/O
Only for Transmitter Wiring
P0 EtherNet/IP Terminal: 1
Only for Display code: 3 or N

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
49
(Continued)
1 M4 Screw-type
Transmitter Wiring Terminal
2 Clamp Type
1 With Display (English, Multi-language)
2 With Display (English, Chinese)
Display Only for Communication
3 With Display (English)
and I/O: P0
N Without Display
Optional Specification /# Refer to optional specification table.

●Signal Cable

Model Suffix Code Optional Code Description


AX01C Magnetic Flowmeter Signal Cable
Unfinished, Cable length ### m, Set of Finishing Parts for M4
-A### (*1)
Screws
Cable Finish and -B### (*1) Finished for AXG1A, Cable Length ### m
Length
-C### (*1) Finished for AXG4A, Cable Length ### m
-D### (*1) Finished for AXFA11, Cable Length ### m
Finishing Parts /C# (*2) Finishing Parts (# sets)
*1: Specify the cable length in the "###" with the numerical value three digits (001 to 200) as multiple of 1 meter (e.g. 001, 002, or 005) for a length
up to 5 m, as multiple of 5 meters up to 100 m (e.g. 010, 020, or 100), or as multiple of 10 meters up to 200 m (e.g. 110, 120, or 200).
The maximum cable length: -A###: 200 m, -B###: 200 m, -C###: 100 m, -D###: 200 m
5 m (16 ft) when using with Marine Approval Type
*2: Specify the finishing parts quantity in the "#" with the numerical value one digit (1 to 9).

●Details: Communication and I/O (HART type, BRAIN type)


Communication Number of Input and Output
and I/O Code Pulse/ Pulse/Status Pulse/Status
Type Current Status Status Current Current
Status Output Active Output Active
Output Input (No- Output Output Input
BRAIN HART 7 Output (with internal (without internal
Active voltage) Passive Passive Active
Passive resistor) resistor)
Type A DA JA 1 1 ― ― ― ― ― ―
Type B DB JB 2 2 ― ― ― ― ― ―
Type C DC JC 2 1 1 ― ― ― ― ―
Type D DD JD 1 2 ― 1 ― ― ― ―
Type E DE JE 1 2 1 ― ― ― ― ―
Type F DF JF 1 1 1 ― 1 ― ― ―
Type G DG JG 1 1 1 ― ― 1 ― ―
Type H DH JH 1 1 ― ― ― ― 1 1
Type J DJ JJ 1 2 ― ― ― ― ― 1
Type K DK JK 1 1 1 ― ― ― ― 1

●Details: Communication and I/O (IS Output)


Communication Number of Input and Output
and I/O Code Pulse/Status Output
Type Current Output Pulse/Status Output
Passive
BRAIN HART Passive Passive
(NAMUR)
Type P DP JP 2 1 ―
Type Q DQ JQ 2 2 ―
Type R DR JR 2 ― 1
Type S DS JS 2 ― 2
Type T DT JT 1 1 ―

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
50
●Details: Communication and I/O (Modbus type)
Communication Number of Input and Output
Type and I/O Code Current Output Pulse/ Status Output Current Input
Modbus Active Passive Active
Type 0 M0 ― 1 ―
Type 2 M2 ― 1 1
Type 6 M6 1 1 ―

●Details: Communication and I/O (FOUNDATION Fieldbus type)


Communication Number of Input and Output
Type and I/O Code
Current Output Pulse/ Status Output Current Input
FOUNDATION Fieldbus Active Passive Active
Type F0 F0 ― 1 ―

●Details: Communication and I/O (PROFIBUS PA type)


Communication Number of Input and Output
Type and I/O code
Current Output Pulse/Status Output Current Input
PROFIBUS PA Active Passive Active
Type G0 G0 ― 1 ―

●Details: Communication and I/O (EtherNet/IP type)


Communication Number of Input and Output
Type and I/O code
Current Output Pulse/Status Current Input
EtherNet/IP Active Output Active
Type P0 P0 ― ― ―

●Details: Restriction for Explosion protection type


For Explosion protection type, the following combinations of suffix code or optional code are restricted. For other
optional codes, see optional code tables.
Restriction of Combination
Item Code
Mandatory Not Available
• Optional Code: EC • Use: -G, -W, -H
• Process Connection: AG1, AJ#, AP1, BG1, BJ#, BP1,
CG1, CJ#, CS#, DJ#, EA4, PJ1
ATEX Flameproof KF2
• Cable Entry: 0 (JIS G1/2)
• Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: CS, RW, GAN
• Communication and I/O: Type P, Q, R, S, T • Use: -G, -W, -H
• Optional Code: EC • Construction: D, E, G (Remote Sensor)
ATEX Flameproof
• Transmitter Wiring Terminal: 2 • Process Connection: AG1, AJ#, AP1, BG1, BJ#, BP1,
with Intrinsically Safe KJ2
CG1,CJ#, CS#, DJ#, EA4, PJ1
output
• Cable Entry: 0 (JIS G1/2)
• Optional Code: CS, RW, GAN
• Communication and I/O: Type F0, G0 • Use: -G, -W, -H
ATEX Flameproof
• Optional Code: EC • Construction: D, E, G (Remote Sensor)
with Intrinsically Safe
• Transmitter Wiring Terminal: 2 • Process Connection: AG1, AJ#, AP1, BG1, BJ#, BP1,
output, FOUNDATION KT2
CG1,CJ#, CS#, DJ#, EA4, PJ1
Fieldbus / PROFIBUS
• Cable Entry: 0 (JIS G1/2)
PA • Optional Code: CS, RW, GAN
• Use: -G, -W, -H
• Cable Entry: 0 (JIS G1/2)
IECEx Flameproof SF2 ― • Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC (Excludes combination with
optional code WCD)
• Communication and I/O: Type P, Q, R, S, T • Use: -G, -W, -H
IECEx Flameproof
• Transmitter Wiring Terminal: 2 • Construction: D, E, G (Remote Sensor)
with Intrinsically Safe SJ2
• Cable Entry: 0 (JIS G1/2)
output
• Optional Code: EC
IECEx Flameproof • Communication and I/O: Type F0, G0 • Use: -G, -W, -H
with Intrinsically Safe • Transmitter Wiring Terminal: 2 • Construction: D, E, G (Remote Sensor)
output, FOUNDATION ST2 • Cable Entry: 0 (JIS G1/2)
Fieldbus / PROFIBUS • Optional Code: EC
PA

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
51
(Continued)
• Cable Entry: 2 (ASME 1/2NPT) • Use: -G, -W, -H
• Grounding Device: 3
FM Flameproof FF2 • Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC
• Optional Code: GBP, GBT
• Cable Entry: 2 (ASME 1/2NPT) • Use: -G, -W, -H
• Communication and I/O: Type P, Q, R, S, T • Construction: D, E, G (Remote Sensor)
FM Flameproof with
FJ2 • Transmitter Wiring Terminal: 2 • Grounding Device: 3
Intrinsically Safe output
• Optional Code: EC
• Optional Code: GBP, GBT
FM Flameproof with • Cable Entry: 2 (ASME 1/2NPT) • Use: -G, -W, -H
Intrinsically Safe • Communication and I/O: Type F0, G0 • Construction: D, E, G (Remote Sensor)
output, FOUNDATION FT2 • Transmitter Wiring Terminal: 2 • Grounding Device: 3
Fieldbus / PROFIBUS • Optional Code: GBP, GBT
PA • Optional Code:EC
• Cable Entry: 2 (ASME 1/2NPT) • Use: -G, -W, -H
• Optional Code: CS • Process Connection: EA4
• Lining: C
FMc Flameproof
CF2 • Grounding Device: 3
(Canada)
• Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC
• Optional Code: GBP, GBT, RW, GAN
• Cable Entry: 2 (ASME 1/2NPT) • Use: -G, -W, -H
• Communication and I/O: Type P, Q, R, S, T • Construction: D, E, G (Remote Sensor)
FMc Flameproof with • Transmitter Wiring Terminal: 2 • Process Connection: EA4
Intrinsically Safe output CJ2 • Optional Code: CS • Lining: C
(Canada) • Grounding Device: 3
• Optional Code: EC
• Optional Code: GBP, GBT, RW, GAN
• Cable Entry: 2 (ASME 1/2NPT) • Use: -G, -W, -H
FMc Flameproof • Communication and I/O: Type F0, G0 • Construction: D, E, G (Remote Sensor)
with Intrinsically Safe • Transmitter Wiring Terminal: 2 • Process Connection: EA4
output, FOUNDATION CT2 • Optional Code: CS • Lining: C
Fieldbus / PROFIBUS • Grounding Device: 3
PA (Canada) • Optional Code: EC
• Optional Code: GBP, GBT, RW, GAN
• Optional Code: VE, VR • Use: -G, -W, -H
• Cable Entry: 0 (JIS G1/2)
EAC Flameproof GF2
• Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC, CS, RW, GAN
• Communication and I/O: Type P, Q, R, S, T • Use: -G, -W, -H
EAC Flameproof with • Transmitter Wiring Terminal: 2 • Construction: D, E, G (Remote Sensor)
GJ2
Intrinsically Safe output • Optional Code: VE, VR • Cable Entry: 0 (JIS G1/2)
• Optional Code: EC, CS, RW, GAN
• Communication and I/O: Type F0 • Use: -G, -W, -H
EAC Flameproof with
• Transmitter Wiring Terminal: 2 • Construction: D, E, G (Remote Sensor)
Intrinsically Safe output, GT2
• Optional Code: VE, VR • Cable Entry: 0 (JIS G1/2)
FOUNDATION Fieldbus
• Optional Code: EC, CS, RW, GAN
• Cable Entry: 4 (ISO M20) • Use: -G, -W, -H
• Optional Code: V5# • Process Connection: C##
• Cable Entry: 0 (JIS G1/2), 2 (ASME 1/2NPT)
Japan Flameproof JF5 • Communication and I/O: Type P, Q, R, S, T, P0
• Display (Integral Flowmeter, Transmitter):
N (Without Display)
• Optional Code: EC
• Use: -G, -W, -H
• Cable Entry: 0 (JIS G1/2)
NEPSI Flameproof NF2 ―
• Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC
• Communication and I/O: Type P, Q, R, S, T • Use: -G, -W, -H
NEPSI Flameproof
• Transmitter Wiring Terminal: 2 • Construction: D, E, G (Remote Sensor)
with Intrinsically Safe NJ2
• Cable Entry: 0 (JIS G1/2)
output
• Optional Code: EC
• Use: -G, -W, -H
• Cable Entry: 0 (JIS G1/2)
Korea Flameproof PF2 ― • Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC
• Optional Code: JC
• Use: -G, -W, -H
INMETRO Flameproof • Cable Entry: 0 (JIS G1/2)
UF2 ―
(Brazil) • Communication and I/O: Type P, Q, R, S, T, P0
• Optional Code: EC, CS, JC

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
52
n OPTIONAL CODE
●Application, Usage, and Operating Function
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Finish the inner surface of the PFA lining (sizes 15 to
400 mm (0.5 to 16 in.), except for high pressure type)
Mirror Finished
to a mirror finish. The Ra is average of measured
PFA
values on several points.      ― PM
(for adhesive
Sizes 15 to 200 mm (0.5 to 8 in.) : Ra 0.05 to 0.15 μm
fluid)
Sizes 250 to 400 mm (10 to 16 in.) : Ra 0.05 to 0.25
μm
Mirror
Finish the inner surface of the ceramics tube (5 to
Finished
200 mm (0.2 to 8 in.)) to a mirror finish with Ra 0.1
Ceramics   ― ― ― ― CM
μm or less. The Ra is average of measured values
(for adhesive
on several points.
fluid)
For permeable fluid applications (e.g. nitric acid,
hydrofluoric acid, high temperature sodium
Vent Hole hydroxide, black liquor etc.). A vent hole is provided
(for permeable for letting fluid permeated between the lining and   ― ― ― ― H
fluid) the measuring pipe escape.
Applicable for flange type of PFA lining except for
high pressure type.
Built-in DC noise cut circuit. It works effectively
when the size is 15 mm (0.5 in.) or more and fluid
DC Noise Cut conductivity is 50 μS/cm or more. Empty pipe
Circuit detection, electrode adhesion diagnosis, electrode
 ― ―  ―  ELC
(for electrolytic potential measurement, and wetted resistance
bath) measurement function can not be used. For remote
transmitter, it must be combined with remote
sensor of size 15 mm (0.5 in.) or more.
Urethane resin potting is applied in the terminal box
Potting of a remote sensor. Signal and excitation cables
Terminal Box (when optional code L### is not selected, cable
with Cable length is each 30 m) are pre-wired and waterproof
(For district glands with union joints are attached at factory.
―  ― ―  ― DHC
heating and For cable entry, selection of JIS G1/2 female thread
cooling or is necessary.
condensation- When optional code DHC is selected, the optional
proof) code of plastic and waterproof glands can not be
selected.
Change the length of signal cable and excitation
cable pre-wired for a remote sensor of Submersible
or one with optional code DHC. Specify the cable
length in the "###" with the numerical value three
digits (001 to 200) as multiple of 1 meter (e.g. 001,
002, or 005) for a length up to 5 m, as multiple of 5
Signal and
meters up to 100 m (e.g. 010, 020, or 100), or as
Excitation ―   ―  ― L###
multiple of 10 meters up to 200 m (e.g. 110, 120, or
Cable Length
200).
The maximum cable length is 100 m in combination
with the AXG4A transmitter, and 200 m in
combination with the AXG1A or AXFA11 transmitter.
When optional code L### is not selected, a
30-meter length cable is pre-wired.
This specification provides AXG with the lay length
that are compatible with previous models(ADMAG,
Wafer Type
YEWMAG Series) in wafer type. Please be sure
Replacement    ― ― ― RW
to select the option code GAN at the same time.
Model
For details on dimensions, please refer to the
DIMENSIONAL DRAWINGS.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
53
●Application, Usage, and Operating Function (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Electrodes, linings, grounding devices (grounding
rings plate type, metal hat grounding ring, grounding
rings electrode type, built-in grounding electrodes),
Oil Prohibited gaskets, and piping adapters and connection parts
  ―   ― K1
Use (for Hygienic) of sizes 2.5 to 400 mm (0.1 to 16 in.)
are assembled and packed with polyethylene after
being cleaned with water and acetone and dried
with air. The label "OIL FREE" is affixed.
Electrodes, linings, and grounding devices
(grounding rings plate type, metal hat grounding
ring, grounding rings electrode type, built-in
Oil Prohibited
grounding electrodes) of sizes 2.5 to 400 mm
Use with   ― ― ― ― K5
(0.1 to 16 in.) are assembled and packed with
Dehydration
polyethylene including desiccants after being
cleaned with water and acetone and dried with air.
The label "OIL & WATER FREE" is affixed.
The flow rate calculation is performed in mass
unit. In addition to fluid density, specify span flow
rate, pulse weight, and totalization weight in mass
Mass Unit
unit. For specifying procedures, read “Ordering      ― MU
Setting
Information”.
For remote sensor, specified parameters are set in
the transmitter that is ordered in combination.
The current output signal is set as follows when
shipped.
Output signal at CPU failure or alarm occurrence:
Signal Down 2.4 mA (–10 %) or less
 ― ―  ―  C1
on Failure (The standard setting is 21.6 mA (110%) or more
at CPU failure or alarm occurrence.)
Not with Communication and I/O code M0, M2,
F0, G0, P0.
The current output signal is set as follows when
shipped.
Signal Down
Output signal limits: 3.8 to 20.5 mA
on Failure
Output signal at CPU failure or alarm occurrence:  ― ―  ―  C2
(NAMUR NE
Low: 2.4 mA (–10%) or less
43 Compliant)
Not with Communication and I/O code M#, F0,
G0, P0.
The current output signal is set as follows when
shipped.
Signal Up
Output signal limits: 3.8 to 20.5 mA
on Failure
Output signal at CPU failure or alarm occurrence:  ― ―  ―  C3
(NAMUR NE
High: 21.6 mA (110%) or more
43 Compliant)
Not with Communication and I/O code M#, F0,
G0, P0.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
54
●Application, Usage, and Operating Function (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
The "Enhanced Dual Frequency Excitation Method"
can be used. For difficult applications such as for
high concentration slurries or low conductivity fluid,
extremely stable measurements can be realized.
The meter factor for the enhanced dual frequency
excitation obtained by flow calibration is inscribed
on the Integral Flow Meter or Remote Sensor
name plate and set into the combined Remote
Transmitter in addition to the meter factor for the
standard dual frequency excitation.
Applicable Specifications:
Enhanced
• Size: 25 to 200 mm (1 to 8 in.)
Dual
• Use: -G, -W, -H
Frequency       HF2
• Construction: A, E, G
Excitation
• Accuracy: B
Type
• Communication and I/O: HART, BRAIN
Not applicable with the following optional code:
• JC (Flow Calibration in Japan)
To use the Enhanced Dual Frequency Excitation
with a remote type, HF2 must be added to both a
Sensor and a Transmitter.
*The AXG4A adds a Dual Frequency Excitation.
When used in combination with a remote sensor
for flow calibration, the transmitter is shipped with
both meter factors for Dual Frequency Excitation
and Enhanced Dual Frequency Excitation.
A microSD card slot is added to the display unit,
and a microSD card (capacity 1 GB, format FAT 16)
is inserted when shipped.
microSD Card When using parameter store / restore function with  ― ―  ―  MC
microSD card, and/or data logging function, specify
optional code MC. Be careful that the microSD card slot
is not mounted unless optional code MC is specified.
CE marking is indicated on the nameplate. When
a flowmeter is used in the countries where CE
marking is required, specify optional code EC.
Optional code EC cannot be applicable for AXG500.
Applicable for the following process connection codes.
CE Marking       EC
AA#, AE#, BA#, BE#, CA#, CE#, DE#, GU#,
H##(*), J##(*), K##, PA#, PE#
*: ‌It can not be combined with optional code W2.
Not applicable with the following specifications:
• Optional code: 3A (3-A Sanitary Certification)
Compliant to NAMUR NE21 under span setting
of 0.5 m/s or more in terms of flow velocity. For
specifiable span, read "Ordering Information".
NAMUR NE21  ― ―  ―  E21
Combination with optional code EC (CE marking)
is necessary.
Not with Communication and I/O code M#, F0, G0, P0.
Compliant to CSA standards.
Integral flowmeter and remote sensor (for size 2.5
to 400 mm) are registered with CRN in Canada.
When the product is used in Canada, it is mandatory to
comply with these standards. Specify option code CS.
Optional code CS cannot be applicable for AXG500.
Canada Applicable for the following process connection codes.
Domestic AA#, BA#, CA#, EA4, H##(*), J##(*), K##, PA#       CS
Sales *: It can not be combined with optional code W2.
Not applicable with the following specifications:
• Lining: C (Ceramics Tube)
• Optional code: EC (CE Marking)
• Optional code: VR, VE (EAC Marking)
• Optional code: JC (Flow Calibration in Japan)
• Optional code: RW (Wafer Type Replacement Model)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
55
●Application, Usage, and Operating Function (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Identifies the final destination as Japan.
Japan
Mandatory when the final destination is Japan.
Domestic       PJ
Not applicable when the final destination is not in
Sales
Japan.
Compliant to 3-A sanitary standards.
Use EPDM rubber gasket for 3-A standard.
Process connection code: HAB
For remote type, only AXG4A remote transmitter
3-A Sanitary can be combined.
― ― ―    3A
Certification Nominal size:15 mm to 100 mm, except 32 mm
Not applicable with the following specifications:
• Optional code: EC (CE Marking)
• Optional code: VR, VE (EAC Marking)
• Optional code: JC (Flow Calibration in Japan)
EAC approval marking and Russian pattern approval
marking are indicated on the nameplate. When the product
is used in Russian Federation, specify optional code VR.
Not applicable with the following specifications:
• Size: 500 mm
EAC Approval
• Communication and I/O: P0 (EtherNet/IP)
and Russian
• Optional code: EC (CE Marking)       VR
Pattern Approval
• Optional code: CS (Canada Domestic Sales)
Marking
• Optional code: 3A (3-A Sanitary Certification)
• Optional code: JC (Flow Calibration in Japan)
• Optional code: WCD (Marine Approval)
• Optional code: RW (Wafer Type Replacement
Model)
EAC approval marking is indicated on the
nameplate. (no Russian pattern approval marking).
When the product is used in EEU except for
Russian Federation, specify optional code VE.
Not applicable with the following specifications:
EAC Approval
• Size: 500 mm
Marking without
• Communication and I/O: P0 (EtherNet/IP)
Russian Pattern       VE
• Optional code: EC (CE Marking)
Approval
• Optional code: CS (Canada Domestic Sales)
Marking
• Optional code: 3A (3-A Sanitary Certification)
• Optional code: JC (Flow Calibration in Japan)
• Optional code: WCD (Marine Approval)
• Optional code: RW (Wafer Type Replacement
Model)
Compliant to the functional safety standard
IEC61508.
When the product is used in a safety instrumented
system, specify optional code SL. This product can
SIL be used in safety instrumented systems up to SIL2
 ― ―  ―  SL
Certification in simplex configuration and SIL3 in redundant
configuration.
Not applicable with the following specifications:
• Communication and I/O: M#, F0, G0, P0
• Optional code: ELC (DC noise cut circuit)
For details, refer to the general specifications (GS
01E22A21-04EN)
Marine
Not applicable with the following specifications:    ― ―  WCD
Approval
• Optional code: RW (Wafer Type Replacement
Model)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
56
●Application, Usage, and Operating Function (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Compliant to the TSG (Pressure Grade GC1) of
China.
TSG (China
Pressure Applicable Specifications:
Standard) • Size: 50 to 500 mm (2 to 20 in.)
   ― ― ― TS1
Certification • Process Connection: AA#, AE#, BA#, BE#, CA#,
(Pressure CE#, EA4, PA#, PE#
Grade GC1)
Not applicable with the following specification:
• Lining: C (Ceramic Tube)
Compliant to the TSG (Pressure Grade GC2) of
China. Liquid penetrant test is not performed.

TSG (China Applicable Specifications:


Pressure • Size: 50 to 500 mm (2 to 20 in.)
Standard) • Process Connection: AA#, AE#, BA#, BE#, CA#,
   ― ― ― TS2
Certification CE#, EA4, PA#, PE#
(Pressure
Grade GC2) Not applicable with the following specifications:
• Lining: C (Ceramic Tube)
• Optional Code:PTC(TSG (China Pressure
Standard) Liquid Penetrant Test)

●Tag Plate and Mounting Bracket


: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
The pendant type tag plate (stainless steel 304) is
wired around the flowmeter neck. Select optional
Stainless Steel code SCT when necessary in addition to that on the
Tag Plate nameplate, on which the Tag No. is inscribed.       SCT
Plate size (Height x Width):
Approx. 12.5 mm x 40 mm (4.92 in. x 15.7 in.)
Stainless Steel Change the material of the remote transmitter mounting
Mounting Bracket bracket, from carbon steel to stainless steel 304. ― ― ― ― ―  SB

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
57
●Piping Parts
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
Hygienic
General-purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Code
Explosion protection
Integral Remote Remote Integral Remote
Flowmeter Sensor Sensor Flowmeter Sensor
The mounting bolts, nuts and gaskets of wafer
type (process connection code: AJ1, AJ2, AA1)
are supplied. For PFA lining and ceramics tube,
when adopting the optional code BSC together
with the optional earth ring plate, there is a risk of
liquid leakage due to the difference in elasticity, so
between the detector and the earth ring, also using
Bolts, Nuts
a gasket of hardness equivalent to chloroprene
and Gaskets    ― ― BSC
rubber is recommended.
(Type C)
Bolt: Stainless steel 304
Nut: Stainless steel 304
Gasket(*):
Chloroprene rubber (CR),
thickness: 3 mm (0.12 in.)
*: ‌The allowable temperature and pressure is
equivalent to that of Valqua #2010 series.
The mounting bolts, nuts and gaskets of wafer type
(process connection code: AJ1, AJ2, AA1) are supplied.
Bolt: Stainless steel 304
Bolts, Nuts Nut: Stainless steel 304
and Gaskets Gasket(*):    ― ― BSF
(Type F) PTFE-sheathed non-asbestos joint sheet,
thickness: 3 mm (0.12 in.)
*: ‌The allowable temperature and pressure is
equivalent to that of Valqua #7030 (S) series.
Connection parts for hygienic are supplied.
Optional code W2 can be selected with the
following process connection codes.
HJA:
Clamp: Stainless steel SCS13
Ferrule:
Size 15 mm (0.5 in.): Stainless steel 316L
Hygienic
Sizes 25 to 125 mm (1 to 5 in.): Stainless steel 304
Connection ― ― ―   W2
Gasket: Ethylene propylene diene rubber
Parts
(EPDM) (*)
HJB:
Clamp: Stainless steel SCS13
Ferrule: Stainless steel 316L
Gasket: Ethylene propylene diene rubber (EPDM) (*)
*: ‌The gasket material is silicone rubber, when size
125 mm (5 in.) or optional code GH is selected.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
58
●Grounding Device
Grounding devices are attached at factory.
For the applicable condition of grounding devices and gaskets, see the separate table.
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
Hygienic
General-purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Code
Explosion protection
Integral Remote Remote Integral Remote
Flowmeter Sensor Sensor Flowmeter Sensor
Material: Stainless Steel 316L, Thin Type(*).
Grounding
Thickness:
Rings    ― ― GRL
1 mm (0.04 in.) for sizes 2.5 to 200 mm (0.1 to 8 in.)
(Plate Type L)
2 mm (0.08 in.) for sizes 250 to 400 mm (10 to 16 in.)
Material: Stainless Steel 316L, Thick Type(*).
Thickness:
Except for high pressure type (ASME Class 600
flange):
Grounding
3 mm (0.12 in.) for sizes 2.5 to 400 mm (0.1 to 16 in.)
Rings    ― ― GRN
4 mm (0.16 in.) for size 500 mm (20 in.)
(Plate Type N)
For high pressure type (ASME Class 600 flange):
8.5 mm (0.33 in.) for size 25 mm (1 in.)
10.5 mm (0.41 in.) for sizes 40 to 100 mm (1.5
to 4 in.).
Material: Nickel Alloy, Thin Type(*).
Grounding
Thickness:
Rings    ― ― GRH
1 mm (0.04 in.) for sizes 2.5 to 200 mm (0.1 to 8 in.)
(Plate Type H)
2 mm (0.08 in.) for sizes 250 to 400 mm (10 to 16 in.)
Material: Nickel Alloy, Thick Type(*).
Grounding
Thickness:
Rings    ― ― GRJ
3 mm (0.12 in.) for sizes 2.5 to 400 mm (0.1 to 16 in.)
(Plate Type J)
4 mm (0.16 in.) for size 500 mm (20 in.)
Material: Titanium, Thin Type(*).
Grounding
Thickness:
Rings    ― ― GRV
1 mm (0.04 in.) for sizes 2.5 to 200 mm (0.1 to 8 in.)
(Plate Type V)
2 mm (0.08 in.) for sizes 250 to 400 mm (10 to 16 in.)
Grounding Material: Titanium, Thick Type(*).
Rings Thickness:    ― ― GRW
(Plate Type W) 3 mm (0.12 in.) for sizes 2.5 to 400 mm (0.1 to 16 in.)
Metal Hat Attach the metal hat grounding ring on upstream
Grounding Ring side and the grounding ring on downstream side.
(Upstream Side) Material: Stainless Steel 316L    ― ― GSN
Grounding Ring Thickness:
(Downstream Side) 3 mm (0.12 in.) for sizes 80 to 400 mm (3 to 16 in.)
Metal Hat Attach the metal hat grounding rings on both
Grounding upstream and downstream sides.
Rings Material: Stainless Steel 316L    ― ― GDN
(Upstream and Thickness:
Downstream Side) 3 mm (0.12 in.) for sizes 80 to 400 mm (3 to 16 in.)
Attach the grounding rings for wafer type
replacement model. This ensures the AXG have
the lay length compatible with previous models
(ADMAG, YEWMAG Series). Please be sure
Grounding Ring
to select the option code RW at the same time.
For Wafer Type
For details on dimensions, please refer to the    ― ― GAN
Replacement
DIMENSIONAL DRAWINGS.
Model
Material: Stainless Steel F316L
Thickness:please check the DIMENSIONAL
DRAWINGS.
Material: Platinum-Iridium
Width:
14 mm (0.55 in.) for sizes 2.5 to 15 mm (0.1 to 0.5
Grounding
in.), sizes 25 to 125 mm (1 to 5 in.) with process
Rings
connection Wafer (A##).    ― ― GRP
(Electrode
14.5 mm (0.57 in.) for sizes 25 to 125 mm (1 to 5
Type P)
in.) with process connection Flange (B##, C##,
E##, P##).
17 mm (0.67 in.) for sizes 150 to 200 mm (6 to 8 in.)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
59
●Grounding Device (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
Hygienic
General-purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Code
Explosion protection
Integral Remote Remote Integral Remote
Flowmeter Sensor Sensor Flowmeter Sensor
Material: Tantalum
Width:
14 mm (0.55 in.) for sizes 2.5 to 15 mm (0.1 to 0.5
Grounding
in.), sizes 25 to 125 mm (1 to 5 in.) with process
Rings
connection Wafer (A##)    ― ― GRT
(Electrode
14.5 mm (0.57 in.) for sizes 25 to 125 mm (1 to 5
Type T)
in.) with process connection Flange (B##, C##,
E##, P##)
17 mm (0.67 in.) for sizes 150 to 200 mm (6 to 8 in.)
Built-in
Material: Platinum-Iridium
Grounding
For electrode material selected by the suffix code,    ― ― GBP
Electrodes
selection of platinum-iridium is necessary.
(Type P)
Built-in
Material: Tantalum
Grounding
For electrode material selected by the suffix code,    ― ― GBT
Electrodes
selection of tantalum is necessary.
(Type T)
*: Either thin type or thick type for the grounding rings can be selected when the material is Stainless Steel 316L, Nickel Alloy, or
Titanium. If the flange pressure ratings is ASME Class 300, EN PN 40 etc. for high fluid pressure and the tightening torque is high,
the thick type is recommended.

Size Range by Grounding Device


Grounding Ring Plate:
Stainless Steel 316L
2.5 to 500 mm, 0.1 to 20 in. (for PFA Lining)
15 to 200 mm, 0.5 to 8 in. (for Ceramics Tube)
Nickel Alloy
2.5 to 500 mm, 0.1 to 20 in. (for PFA Lining)
15 to 200 mm, 0.5 to 8 in. (for Ceramics Tube)
Titanium
2.5 to 400 mm, 0.1 to 16 in. (for PFA Lining)
15 to 200 mm, 0.5 to 8 in. (for Ceramics Tube)
Metal Hat Grounding Ring:
Stainless Steel 316L
80 to 400 mm, 3to 16 in. (for PFA Lining, Flange
type)
Grounding Ring For Wafer Type Replacement Model:
Stainless Steel F316L
25 to 200 mm, 1 to 8 in.(for PFA Lining)
Grounding Ring Electrode:
Platinum-Iridium
2.5 to 200 mm, 0.1 to 8 in. (for PFA Lining)
15 to 200 mm, 0.5 to 8 in. (for Ceramics Tube)
Tantalum
2.5 to 200 mm, 0.1 to 8 in. (for PFA Lining)
15 to 200 mm, 0.5 to 8 in. (for Ceramics Tube)
Built-in Grounding Electrode:
Platinum-Iridium
150 to 400 mm, 6 to 16 in. (for PFA Lining,
Flange type)
Tantalum
150 to 400 mm, 6 to 16 in. (for PFA Lining,
Flange type)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
60
●Gasket
Grounding devices are attached at factory.
For applicable condition of grounding devices and gaskets, see the separate table.
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
Hygienic
General-purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Code
Explosion protection
Integral Remote Remote Integral Remote
Flowmeter Sensor Sensor Flowmeter Sensor
Fluororubber gasket (Viton) for plastic piping such
as PVC.
Plastic Pipe
The allowable temperature and pressure range is    ― ― GA
Gaskets
the same as those of Valqua #4010 with no special
formulation.
Acid-resistant fluororubber gasket (Viton) for
Plastic Pipe plastic piping such as PVC.
Acid-resistant The allowable temperature and pressure range is    ― ― GC
Gaskets the same as those of Valqua #4010 with special
formulation D2470.
Alkali-resistant fluororubber gasket (Viton) for
Plastic Pipe
plastic piping such as PVC.
Alkali-
The allowable temperature and pressure range is    ― ― GD
resistant
the same as those of Valqua #4010 with special
Gaskets
formulation D0970.
Alkali-resistant (fluorocarbon resin containing
Metal Pipe carbon) gaskets for use with metal piping.
Alkali- The allowable temperature and pressure range is
resistant the same as those of Valqua #7026.   ― ― ― GF
Gaskets Target specification
• Lining: C (Ceramics Tube)
For Hygienic (sizes 15 to 25, and 40 to 125 mm (0.5
to 1, and 1.5 to 5 in.)), change the material of the
Hygienic gasket fixed between the measuring pipe and piping
Use Silicone connection adapter from ethylene propylene diene
Rubber rubber (EPDM)) to silicone rubber. Select optional ― ― ―   GH
Gaskets code GH, when the fluid temperature is 120 °C (248
°F) or more (Maximum: 160 °C (320 °F)), (Except
optional code 3A.)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
61
●Details: Applicable Condition for Grounding Devices and Gaskets
: Applicable ―: Not Applicable
Lining PFA Lining Ceramics Tube
Flange Clamp
High Union
Process Connection Wafer Union Joint Wafer
Except for High Pressure Type Pressure Butt Weld
Type Joint
Size 2.5 to 15 25 to 125 150 to 200 250 to 400 500 25 to 100 2.5 to 200 15 to 125 2.5 to 10 15 to 200
mm (inch) (0.1 to 0.5) (1 to 5) (6 to 8) (10 to 16) (20) (1 to 4) (0.1 to 8) (0.5 to 5) (0.1 to 0.4) (0.5 to 8)
Code GA
GA GA GA GA GA GA GA
(Gasket) Not Not Not Not Not Not Not Not Not Not GC
GC GC GC GC GC GC GC GH GF
Code selected selected selected selected selected selected selected selected selected selected GD
GD GD GD GD GD GD GD
(Grounding Device) GF
Not selected  ―  ―  ―  ―  ― ― ―  ―      ―
GRL  ―  ―  ― *1 ― ― ― ― ―  ― ― ― ― ― ― ―
GRN ―      *1 ―  ―  ― ―  ― ― ― ―  
GRH  ―  ―  ― *1 ― ― ― ― ―  ― ― ― ― ― ― ―
GRJ ―      *1 ―  ― ― ― ―  ― ― ― ―  
GRV  ―  ―  ― *1 ― ― ― ― ―  ― ― ― ― ― ― ―
GRW ―      *1 ― ― ― ― ― ―  ― ― ― ―  
GRP       ― ― ― ― ― ―   ― ― ― ―  
GRT       ― ― ― ― ― ―   ― ― ― ―  
GBP*2 ― ― ― ―  ― *1 ― ― ― ― ― ― ― ― ― ― ― ― ―
GBT*2 ― ― ― ―  ― *1 ― ― ― ― ― ― ― ― ― ― ― ― ―
GSN ― ―  ―  ―  ― ― ― ― ― ― ― ― ― ― ― ― ―
GDN ― ―  ―  ―  ― ― ― ― ― ― ― ― ― ― ― ― ―
GAN ― ― ― ― ― ― ― ― ― ― ― ―   ― ― ― ― ― ―

*1: Not applicable for process connection code BE3, PE3 (EN PN25 flange) of sizes 350, 400 mm.
*2: Not applicable for process connection code BE3, PE3 (EN PN25 flange).

●Direction of Cable Entry, Cable Glands


: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Rotate the transmitter of integral flowmeter or
Cable Entry the terminal box of remote sensor and change
Direction the direction of the cable entry (+90, +180, or -90      ― RH
Change degree). For specifying procedures, read “Ordering
Information”.
Waterproof 2 pcs. of waterproof gland, and no blanking plug.
Glands Available only for cable entry code 0 (JIS G1/2 ―  ― ―  ― EG
(Type G) female thread).
Waterproof 2 pcs. of waterproof gland, and a blanking plug.
Glands Available only for cable entry code 0 (JIS G1/2  ― ―  ― ― EG2
(Type G2) female thread).
Waterproof 3 pcs. of waterproof gland, and no blanking plug.
Glands Available only for cable entry code 0 (JIS G1/2  ― ―  ― ― EG3
(Type G3) female thread).
Waterproof 4 pcs. of waterproof gland, and a blanking plug.
Glands Available only for cable entry code 0 (JIS G1/2 ― ― ― ― ―  EG4
(Type G4) female thread).
Waterproof 5 pcs. of waterproof gland, and no blanking plug.
Glands Available only for cable entry code 0 (JIS G1/2 ― ― ― ― ―  EG5
(Type G5) female thread).
2 pcs. of waterproof gland with union joint, and no
Waterproof
blanking plug.
Glands ―  ― ―  ― EU
Available only for cable entry code 0 (JIS G1/2
(Type U)
female thread).
2 pcs. of waterproof gland with union joint, and a
Waterproof
blanking plug.
Glands  ― ―  ― ― EU2
Available only for cable entry code 0 (JIS G1/2
(Type U2)
female thread).

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
62
●Direction of Cable Entry, Cable Glands (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
3 pcs. of waterproof gland with union joint, and no
Waterproof
blanking plug.
Glands  ― ―  ― ― EU3
Available only for cable entry code 0 (JIS G1/2
(Type U3)
female thread).
4 pcs. of waterproof gland with union joint, and a
Waterproof
blanking plug.
Glands ― ― ― ― ―  EU4
Available only for cable entry code 0 (JIS G1/2
(Type U4)
female thread).
5 pcs. of waterproof gland with union joint, and no
Waterproof
blanking plug.
Glands ― ― ― ― ―  EU5
Available only for cable entry code 0 (JIS G1/2
(Type U5)
female thread).
2 pcs. of plastic gland, and no blanking plug.
Plastic Glands
Available only for cable entry code 0 (JIS G1/2 ―  ― ―  ― EP
(Type P)
female thread).
2 pcs. of plastic gland, and a blanking plug.
Plastic Glands
Available only for cable entry code 0 (JIS G1/2  ― ―  ― ― EP2
(Type P2)
female thread).
3 pcs. of plastic gland, and no blanking plug.
Plastic Glands
Available only for cable entry code 0 (JIS G1/2  ― ―  ― ― EP3
(Type P3)
female thread).
4 pcs. of plastic gland, and a blanking plug.
Plastic Glands
Available only for cable entry code 0 (JIS G1/2 ― ― ― ― ―  EP4
(Type P4)
female thread).
5 pcs. of plastic gland, and no blanking plug.
Plastic Glands
Available only for cable entry code 0 (JIS G1/2 ― ― ― ― ―  EP5
(Type P5)
female thread).
2 pcs. of waterproof gland with JIS G3/4 female,
Waterproof
and no blanking plug.
Glands ―  ― ―  ― EW
Available only for cable entry code 0 (JIS G1/2
(Type W)
female thread).
1 piece of Flameproof gland with JIS G1/2 female,
Flameproof*
and 2 blanking plugs.
gland  ― ―  ― ― V51
Available only for cable entry code 4 (ISO M20×1.5
1 piece
Female thread).
2 pcs. of Flameproof gland with JIS G1/2 female
and;
Flameproof*
- Integral flowmeter: a blanking plug.
gland   ―   ― V52
- Remote sensor: no blanking plug.
2 pcs.
Available only for cable entry code 4 (ISO M20×1.5
Female thread).
3 pcs. of Flameproof gland with JIS G1/2 female
and;
Flameproof*
- Remote transmitter: 2 blanking plugs.
gland  ― ―  ―  V53
- Integral flowmeter: no blanking plug.
3 pcs.
Available only for cable entry code 4 (ISO M20×1.5
Female thread).
4 pcs. of Flameproof gland with JIS G1/2 female,
Flameproof*
and a blanking plug.
gland ― ― ― ― ―  V54
Available only for cable entry code 4 (ISO M20×1.5
4 pcs.
Female thread).
5 pcs. of Flameproof gland with JIS G1/2 female,
Flameproof*
and no blanking plug.
gland ― ― ― ― ―  V55
Available only for cable entry code 4 (ISO M20×1.5
5 pcs.
Female thread).
*: The thread of connection between AXG and Flameproof gland is M20, and the thread of connection between Flameproof gland and
CABLE is G1/2.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
63
●Certificate, Calibration, and Various Test
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Material certificate is issued.
Target Parts:
PFA Lining:
Measuring Pipe, Electrodes, Grounding
Devices (Grounding Rings Plate Type,
Metal Hat Grounding Rings, Grounding
Material Rings Electrode Type, or Built-in Grounding
     ― M01
Certificate Electrodes),
Flanges (for flange type), Mini-flanges (for
wafer type), Adapters for Hygienic
Ceramics Tube:
Grounding Devices (Grounding Rings Plate
Type, or Grounding Rings Electrode Type),
Union Joint
Material For sizes 2.5 to 400 mm (0.1 to 16 in.), except for
Certificate high pressure type, material certificates according to
     ― E01
(EN 10204- EN 10204 Type 3.1 with a dedicated cover is issued.
3.1) The target parts are the same as optional code M01.
Calibration
The Declaration and the Calibration Equipment List
Certificate       L2
are issued.
(Level 2)
Calibration
The Declaration and the Primary Standard List are
Certificate       L3
issued.
(Level 3)
Calibration
The Declaration and the Yokogawa Measuring
Certificate       L4
Instruments Control System are issued.
(Level 4)
ISO/IEC 17025 calibration and certificates with
ILAC MRA mark (Standard flow points) .
Target Specifications:
• Size: 15 to 400 mm (0.5 to 16 in.)
• Accuracy: B (Standard)
• Communication and I/O: D# (BRAIN), J#
(HART)

Not applicable with the following specifications:


• Size: 2.5 to 10 mm, 500 mm (0.1 to 0.4 in., 20 in.)
• Accuracy: C (High Grade)
ISO/IEC
• Construction: D (Remote Sensor (for AXFA11))
17025
• Communication and I/O: F0 (FOUNDATION      ― L10
calibration
Fieldbus), G0 (PROFIBUS PA), M# (Modbus)
(Standard)*1
P0 (EtherNet/IP)
• Optional code: L2, L3, L4 (Calibration
Certificate)
• Optional code: L11, L12 (ISO/IEC 17025
calibration)
• Optional code: SC (Specified Span Five-point
Calibration)
• Optional code: JC (Flow Calibration in Japan)
• Optional code: HF2 (Enhanced Dual Frequency
Excitation Type)
• Optional code: MU (Mass Unit Setting)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
64
●Certificate, Calibration, and Various Test (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
ISO/IEC 17025 calibration and certificates with
ILAC MRA mark (2 points of user-specified flow
span, around 50 and 100%) .
Target Specifications:
• Size: 15 to 400 mm (0.5 to 16 in.)
• Accuracy: B (Standard)
• Communication and I/O: D# (BRAIN), J#
(HART)

Not applicable with the following specifications:


ISO/IEC
• Size: 2.5 to 10 mm, 500 mm (0.1 to 0.4 in., 20 in.)
17025
• Accuracy: C (High Grade)
calibration
• Construction: D (Remote Sensor (for AXFA11))      ― L11
(Specified
• Communication and I/O: F0 (FOUNDATION
span, 2
Fieldbus), G0 (PROFIBUS PA), M# (Modbus)
points)*1
P0 (EtherNet/IP)
• Optional code: L2, L3, L4 (Calibration
Certificate)
• Optional code: L10, L12 (ISO/IEC 17025
calibration)
• Optional code: SC (Specified Span Five-point
Calibration)
• Optional code: JC (Flow Calibration in Japan)
• Optional code: HF2 (Enhanced Dual Frequency
Excitation Type)
ISO/IEC 17025 calibration and certificates with
ILAC MRA mark (4 points of user-specified flow
span, around 25, 50, 75, and 100%).
Target Specifications:
• Size: 15 to 400 mm (0.5 to 16 in.)
• Accuracy: B (Standard)
• Communication and I/O: D# (BRAIN), J#
(HART)

Not applicable with the following specifications:


ISO/IEC • Size: 2.5 to 10 mm, 500 mm (0.1 to 0.4 in., 20 in.)
17025 • Accuracy: C (High Grade)
calibration • Construction: D (Remote Sensor (for AXFA11))
     ― L12
(Specified • Communication and I/O: F0 (FOUNDATION
span, 4 Fieldbus), G0 (PROFIBUS PA), M# (Modbus)
points)*1 P0 (EtherNet/IP)
• Optional code: L2, L3, L4 (Calibration
Certificate)
• Optional code: L10, L11 (ISO/IEC 17025
calibration)
• Optional code: SC (Specified Span Five-point
Calibration)
• Optional code: JC (Flow Calibration in Japan)
• Optional code: HF2 (Enhanced Dual Frequency
Excitation Type)
• Optional code: MU (Mass Unit Setting)
With the customer’s specified span, the actual flow
inspection of 5 points around 0, 25, 50, 75, and
Specified
100% is performed. Instead of the flow inspection
Span
at the standard flow rate of 2 m/s (6.56 ft/s), the      ― SC
Five-point
result of flow inspection with the customer specified
Calibration
span is described in a test certificate (QIC). For
specifiable spans, read “Ordering Information”.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
65
●Certificate, Calibration, and Various Test (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
The actual flow inspection is performed at Yokogawa
Manufacturing Kofu Factory in Japan. The result of
that flow inspection is described in a test certificate
(QIC). To performe the actual flow inspection
reguraly at Kofu factory, specify optional code JC.
For remote type, available only when the
combination of the sensor and the transmitter is
ordered. In this case, specify this optional code JC
for both the sensor and the transmitter. Not available
when the sensor or the transmitter is ordered alone.
Target Specifications:
• Size: 2.5 to 400 mm (0.1 to 16 in.)
• Lining: A (PFA Lining)
Flow
• Accuracy: B (Standard)
Calibration       JC
• Communication and I/O: D# (BRAIN), J#
in Japan
(HART), F0 (FOUNDATION Fieldbus)

Not applicable with the following specifications:


• Size: 500 mm
• Explosion Protection: PF2 (Korea Flameproof),
UF2 (INMETRO Flameproof)
• Lining: C (Ceramics Tube)
• Accuracy: C (High Grade)
• Communication and I/O: G0 (PROFIBUS PA),
P0 (EtherNet/IP)
• Optional code: 3A (3-A Sanitary Certification)
• Optional code: CS (Canada Domestic Sales)
• Optional code: VR, VE (EAC Marking)
The water pressure depending on the process
connection is applied to the lining (measuring pipe)
Hydrostatic for 10 minutes to check that there is no leakage, and
   ― ― ― T01
Test the result is described in a test certificate (QIC).
For the test water pressure on each process
connection, see the separate table.
The water pressure depending on the process
connection is applied to the lining (measuring pipe)
TSG (China for 10 minutes to check that there is no deformation
Pressure and leakage, and the result is described in a TSG
Standard) test certificate format (QIC).    ― ― ― T0C
Hydrostatic For the test water pressure on each process
Test connection, see the separate table.
Be sure to select the optional code TS1 or TS2 at
the same time.
Withstand voltage test on remote sensor (sizes 2.5
Withstand to 400 mm (0.1 to 16 in.)) is performed, and the
Voltage Test result is described in a test certificate (QIC). ―   ―  ― WT1
(Type 1) WT1:
Between excitation current terminal and ground terminal:
1000 V AC for 1 minute
WT2:
Withstand Between excitation current terminal and ground terminal:
Voltage Test 1500 V AC for 1 minute ―   ―  ― WT2
(Type 2) Between signal terminals and excitation current terminal:
1500 V AC for 1 minute
PMI Test Fluorescent X-ray analysis of nickel, chromium and
molybdenum is performed on parts made of stainless    ― ― ― PM1
(Type 1)
steel or nickel alloy, and a test report is issued. For
PMI Test applicable condition, see the separate table.
Target Parts:    ― ― ― PM2
(Type 2)
PM1: Grounding Rings (Plate Type), Metal Hat
PMI Test Grounding Rings
PM2: Flange (Stainless steel only)      ― PM3
(Type 3)
PM3: Measuring Pipe

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
66
●Certificate, Calibration, and Various Test (Continued)
: Applicable : Applicable (except Explosion Protection) ―: Not Applicable
Applicable Model
General-
Hygienic
General-purpose purpose
Submersible Hygienic with
Item Specification and Applicable Condition Explosion protection Explosion Code
Explosion protection
protection
Integral Remote Remote Integral Remote Remote
Flowmeter Sensor Sensor Flowmeter Sensor Transmitter
Liquid penetrant test on welded parts of flanges
Liquid (for flange type) or mini-flanges (for wafer type)
   ― ― ― PT
Penetrant Test is performed and a test report is issued. For
applicable condition, see the separate table.
Liquid penetrant test on welded parts of flanges
TSG (China (for flange type) or mini-flanges (for wafer type) is
Pressure performed and a TSG test certificate format (QIC)
Standard) is issued.    ― ― ― PTC
Liquid For applicable condition, see the separate table.
Penetrant Test Be sure to select the optional code TS1 or TS2 at
the same time.
*1 Please confirm "ISO/IEC 17025 calibration-related confirmation list".

●Details: Water Pressure of Hydrostatic Test ●Details:TSG (China Pressure Standard)


(Optional Code T01): Hydrostatic Test (Optional Code T0C):

Process Water Process Water


Process Process
connection Size: mm (in.) pressure connection Size: mm (in.) pressure
connection connection
code (MPa) code (MPa)
ASME 2.5 to 300 (0.1 to 12) 3.0 ASME 50 to 300 (2 to 12) 3.0
#A1 #A1
Class 150 350 to 500 (14 to 20) 1.5 Class 150 350 to 500 (14 to 20) 1.5
ASME 2.5 to 50 (0.1 to 2) 6.0 ASME 50 (2) 6.0
#A2 #A2
Class 300 65 to 300 (2.5 to 12) 3.0 Class 300 65 to 300 (2.5 to 12) 3.0
ASME ASME
#A4 25 to 100 (1 to 4) 15.5 #A4 50 to 100 (2 to 4) 15.5
Class 600 Class 600
#E1 EN PN10 200 to 500 (8 to 20) 1.5 #E1 EN PN10 200 to 500 (8 to 20) 1.5
65 to 300 (2.5 to 12) 2.4 65 to 300 (2.5 to 12) 2.4
#E2 EN PN16 #E2 EN PN16
500 (20) 1.5 500 (20) 1.5
80 to 300 (3 to 12) 3.0 80 to 300 (3 to 12) 3.0
#E3 EN PN25 #E3 EN PN25
350 to 400 (14 to 16) 1.5 350 to 400 (14 to 16) 1.5
#E4 EN PN40 2.5 to 50 (0.1 to 2) 6.0 #E4 EN PN40 50 (2) 6.0
80 to 300 (3 to 12) 1.8
#G1 JIS F12
350 to 400 (14 to 16) 1.5
2.5 to 300 (0.1 to 12) 2.1
#J1 JIS 10K
350 to 400 (14 to 16) 1.5
2.5 to 50 (0.1 to 2) 6.0
#J2 JIS 20K
65 to 300 (2.5 to 12) 3.0
JPI 2.5 to 300 (0.1 to 12) 3.0
#P1
Class 150 350 to 400 (14 to 16) 1.5
#S1 AS Table D 50 to 400 (2 to 16) 1.1
#S2 AS Table E 50 to 300 (2 to 12) 2.1
GU# Union Joint 2.5 to 10 (0.1 to 0.4) 6.0

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
67
●Details: Applicable Condition for PMI Test
○Grounding Rings (Plate Type), Metal Hat Grounding Rings, Grounding Rings For Wafer Type Replacement
Model (Optional Code PM1)
: Applicable ―: Not Applicable
Lining PFA Lining Ceramics Tube
Clamp
Union Union
Process Connection Flange Wafer Wafer
Butt Weld Joint
Joint
Size
mm (inch) 2.5 to 65 80 to 400 500 2.5 to 200 15 to 125 2.5 to 10 15 to 200
Code (0.1 to 2.5) (3 to 16) (20) (0.1 to 16) (0.5 to 5) (0.1 to 0.4) (0.5 to 8)
(Grounding Device)
Not selected ― ― ― ― ― ― ―
GRL   ―  ― ― ―
GRN   ―  ― ― 
GRH   ―  ― ― ―
GRJ   ―  ― ― 
GRV ― ― ― ― ― ― ―
GRW ― ― ― ― ― ― ―
GSN ―  ― ― ― ― ―
GDN ―  ― ― ― ― ―
GAN ― ― ―  ― ― ―

○Flange (Optional Code PM2)


: Applicable ―: Not Applicable
Lining PFA Lining Ceramics Tube
Clamp
Union
Union
Process Connection Flange Wafer Butt Wafer
Joint
Weld
Joint
Code
(Process H##
Connection) B## C## D## E## P## A## J## G## A##
Size K##
mm (inch)
2.5 (0.1)  ―  ―  ― ― ― ―
5 (0.2)  ―  ―  ― ― ― ―
10 (0.4)  ―  ―  ― ― ― ―
15 (0.5)  ― ― ―  ― ― ― ―
25 (1)  ― ―   ― ― ― ―
32 (1.25)  ― ― ― ― ― ― ― ―
40 (1.5)  ― ―   ― ― ― ―
50 (2)  ― ―   ― ― ― ―
65 (2.5)  ― ― ― ― ― ― ― ―
80 (3)  ― ―   ― ― ― ―
100 (4)  ― ―   ― ― ― ―
125 (5)  ― ― ― ― ― ― ― ―
150 (6)  ― ― ―  ― ― ― ―
200 (8)  ― ― ―  ― ― ― ―
250 (10)  ― ― ―  ― ― ― ―
300 (12)  ― ― ―  ― ― ― ―
350 (14)  ― ― ―  ― ― ― ―
400 (16)  ― ― ―  ― ― ― ―
500 (20) ― ― ― ― ― ― ― ― ―

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
68
○Measuring Pipe (Optional Code PM3)
: Applicable ―: Not Applicable
Lining PFA Lining Ceramics Tube
Process Clamp
Connection Union Union
Flange Wafer Wafer
Size Butt Weld Joint
mm (inch) Joint
2.5 (0.1)   ― ― ―
5 (0.2)   ― ― ―
10 (0.4)   ― ― ―
15 (0.5)    ― ―
25 (1)    ― ―
32 (1.25)    ― ―
40 (1.5)    ― ―
50 (2)    ― ―
65 (2.5)    ― ―
80 (3)    ― ―
100 (4)    ― ―
125 (5)    ― ―
150 (6)   ― ― ―
200 (8)   ― ― ―
250 (10)  ― ― ― ―
300 (12)  ― ― ― ―
350 (14)  ― ― ― ―
400 (16)  ― ― ― ―
500 (20) ― ― ― ― ―

●Details: Applicable Condition for Liquid Penetrant Test (Optional Code PT)
: Applicable ―: Not Applicable
Lining PFA Lining Ceramics Tube
Clamp
Union
Union
Process Connection Flange Wafer Butt Wafer
Joint
Weld
Joint
Code
(Process H##
Connection) B## C## D## E## P## A## J## G## A##
Size K##
mm (inch)
2.5 (0.1) ― ― ― ― ― ― ― ― ―
5 (0.2) ― ― ― ― ― ― ― ― ―
10 (0.4) ― ― ― ― ― ― ― ― ―
15 (0.5) ― ― ― ― ― ― ― ― ―
25 (1)  ― ―   ― ― ― ―
32 (1.25)  ― ― ― ― ― ― ― ―
40 (1.5)  ― ―   ― ― ― ―
50 (2)   ―   ― ― ― ―
65 (2.5)   ― ― ― ― ― ― ―
80 (3)   ―   ― ― ― ―
100 (4)   ―   ― ― ― ―
125 (5)   ― ― ― ― ― ― ―
150 (6)   ― ―   ― ― ―
200 (8)   ― ―   ― ― ―
250 (10)   ― ―  ― ― ― ―
300 (12)   ― ―  ― ― ― ―
350 (14)   ― ―  ― ― ― ―
400 (16)   ― ―  ― ― ― ―
500 (20)   ― ― ― ― ― ― ―

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
69
●Details: Applicable Condition for TSG (China Pressure Standard) Liquid Penetrant Test (Optional Code PTC):
: Applicable ―: Not Applicable
Lining PFA Lining
Process Connection Flange Wafer
Code
(Process
Connection) BA# BE# CA# CE# DE# EA4 PA# PE# AA# AE#
Size
mm (inch)
2.5 (0.1) ― ― ― ― ― ― ― ― ― ―
5 (0.2) ― ― ― ― ― ― ― ― ― ―
10 (0.4) ― ― ― ― ― ― ― ― ― ―
15 (0.5) ― ― ― ― ― ― ― ― ― ―
25 (1) ― ― ― ― ― ― ― ― ― ―
32 (1.25) ― ― ― ― ― ― ― ― ― ―
40 (1.5) ― ― ― ― ― ― ― ― ― ―
50 (2)     ―    ― ―
65 (2.5)     ― ― ― ― ― ―
80 (3)     ―    ― ―
100 (4)     ―    ― ―
125 (5)     ― ― ― ― ― ―
150 (6)     ― ―    
200 (8)     ― ―    
250 (10)     ― ―   ― ―
300 (12)     ― ―   ― ―
350 (14)     ― ―   ― ―
400 (16)     ― ―   ― ―
500 (20)     ― ― ― ― ― ―

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
70
●ISO/IEC 17025 calibration-related confirmation list
○Item to check regarding calibration, etc.
• Calibration values of the calibration certificate are reported as the measured values at the time we performed the
calibration.
• We do not make a statement of conformity.
○Item to check regarding certificates, etc.
• The calibration certificate will be written in both Japanese and English.
• Certificates etc. cannot be duplicated and used again.
• Certificates etc. are not issued electronically.
○Confidentiality
• We promise not to disclose to anyone any business information about our customers that we learn in the course of
carrying out calibration and other work.
• However, we may disclose such information to a third party at our discretion in the following cases.
(1) When disclosing information to a accreditation body when we undergo an audit for ISO/IEC 17025 etc.
(2) When there is an order or request from the law or a goverment agency.
○Calibration specification etc.
• ISO/IEC 17025 calibration (Complied with ISO/IEC 17025, Calibration certificate issued with ILAC MRA mark) will be
performed.
• If the span flow rate unit is other than "m3/h", the unit will be converted to "m3/h", (see "Unit Conversion Values List
(Optional Code L11, L12)").
• If the conversion result exceeds the acceptable flow rate range in "m3/h", it will be adjusted to within the acceptable
flow rate range .
• Zero adjustment will be performed before calibration.
• If no grounding ring is specified, calibration will be performed using the grounding ring from our facility.
• For hygienic and hygienic with explosion protection specifications, calibration is performed using a jig from our
facility that simulates an adapter, the included adapter is not used.
• The calibration conditions for each optional code are shown in "Calibration Specifications" below.
○Calibration Specifications (Optional Code L10, L11, L12)
Optional Code L10 Optional Code L11 Optional Code L12
Setting Span 2.0 m/s Customer-specified Span
Output Frequency 0 Hz - 1 kHz
Number of Calibration Points 3 points 2 points 4 points
Around 100%, 50% of specified Around 100%, 75%, 50%, 25% of
Calibration Points *1, *2, *3 Around 2.0 m/s, 1.0 m/s, 0.4 m/s
span*4 specified span*4
Medium: Water
Calibration Conditions Medium temperature: 15°C ~ 30°C
Ambient temperature: 15°C ~ 25°C
*1 The flow rate is adjusted within a range of ±5%. For the 100% point, it is adjusted within a range of 95% ±5% so as not to exceed
the upper limit.
*2 The 0.4 m/s point will be adjusted within the range of the acceptable flow rate.
*3 If the flow rate exceeds the acceptable range, it will be adjusted to within the range.
*4 The selectable flow rate span of optional codes L11, L12 are as shown in "• Selectable Span Flow Rate Range (Optional Code L11,
L12)".

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
71
・Acceptable Flow Rate Range (Optional Code L10, L11, L12)
Size Min. Flow Rate Max. Flow Rate
mm m3/h m3/h
15 0.26 2.80
25 0.70 10.8
32 1.80 29.0
40 1.80 29.0
50 2.90 43.0
65 7.30 121
80 7.30 121
100 11.3 183
125 26.0 389
150 26.0 389
200 46.0 635
250 104 1141
300 104 1141
350 179 1350
400 179 1350

・Selectable Span Flow Rate Range (Optional Code L11, L12)


Selectable Span Flow Rate Range of L11 Selectable Span Flow Rate Range of L12
Size
mm Min. Span Flow Rate Max. Span Flow Rate Min. Span Flow Rate Max. Span Flow Rate
m3/h m3/h m3/h m3/h
15 0.58 2.80 1.30 2.80
25 1.56 10.8 3.50 10.8
32 4.00 28.9 9.00 28.9
40 4.00 28.0 9.00 28.0
50 6.45 43.0 14.5 43.0
65 16.3 80.0 36.5 80.0
80 16.3 121 36.5 121
100 25.2 183 56.5 183
125 57.8 300 130 300
150 57.8 380 130 380
200 103 635 230 635
250 232 1000 520 1000
300 232 1141 520 1141
350 398 1200 895 1200
400 398 1350 895 1350

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
72
○Unit Conversion Values List (Optional Code L11, L12)
If the span flow rate unit is other than "m3/h", the unit will be converted to "m3/h", using the following conversion
values.
If the conversion result exceeds the acceptable flow rate range in m3/h, the flow rate will be adjusted to within the
acceptable flow rate range and actual flow calibration will be performed.

・Volume Units
Unit Description Conversion Value to "m3"
l liter 0.001
gal(US) US liquid gallon 0.003785412
bbl(US Oil) US Oil barrel 0.158987295
bbl(US Beer) US Beer barrel 0.117347765
cf cubic feet 0.028316847

・Time Units
Unit Description Conversion Value to "h"
s second 1/3600
min minute 1/60
d day 24

・Flow Velocity Units


If the span units are velocity, convert to volumetric flow rate using the nominal size (mm).
If the unit of length is "ft", convert it to "m" using the following:
Unit Description Conversion Value to "m"
ft feet 0.3048

・Prefixes
If a prefix is ​​added, the following values ​​are used for conversion.
Prefix Description Value
M mega 106
k kilo 103
c centi 10-2
m milli 10-3
μ micro 10-6

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
73
n ACCESSORIES
• Centering Device (wafer type only): 1 set
• Blanking Plug: 1 to 2 pcs.
• Gasket (sensor side): 2 sheets
• Mounting Bracket (transmitter only): 1 set
• Dedicated mounting bolt (Size 50 mm / 2 in, Submersible, JIS 20K Wafer only)
Note: Accessories differ depending on specifications to be selected. For the accessories of each optional specification, refer to the optional
code table.

n TERMINAL CONFIGURATION
Remote Sensor: Remote Transmitter:
<To be wired to Remote Transmitter> <To be wired to Remote Sensor>
Non Explosion Protection

Terminal Symbol Description


SA
Explosion protection SB
A Flow Signal Input
B
C
EX1 Excitation Current Output
EX2
F30.ai

Terminal Symbol Description


A
B Flow Signal Output
C
EX1 Excitation Current Input
EX2
Protective Grounding
(Outside of the terminal box)
Functional grounding
(Only for explosion proof type)
F29.ai
Note: When submersible use or optional code DHC is selected,
waterproof glands with union joints and cables are
attached.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
74
Integral Flowmeter and Remote Transmitter: For Communication and I/O Suffix Code P0 (EtherNet/IP)
For Communication and I/O Suffix Code other than P0 <To be wired to Power Supply and PORTs>
(EtherNet/IP)
M4 Screw Type
<To be wired to Power Supply and I/Os>
M4 Screw Type

Terminal Symbol Description


Shorting Screw
Clamp Type (Need to be fixed for normal operation)
Functional Grounding
N/-
Power Supply
L/+
PORT1
Ethernet port (RJ-45, 2 ports)
PORT2
Protective Grounding
(Inside and outside of the terminal box)
F32.ai

For AXG4A FOUNDATION Fieldbus type remote transmitter,


read general specifications (GS 01E21F02-01E).
For AXG4A EtherNet/IP type remote transmitter,
read general specifications (GS 01E21F02-02EN).
For AXG4A PROFIBUS PA type remote transmitter,
read general specifications (GS 01E21F02-03EN).
For AXG1A remote transmitter, read general
Terminal Symbol Description specifications (GS 01E22C01-01EN).
Shorting Screw For AXFA11G remote transmitter, read general
(Need to be fixed for normal operation)
specifications (GS 01E20C01-01E).
Functional Grounding
N/-
Recommended Cable for Excitation, Power and
Power Supply Input/Output:
L/+
JIS C 3401 control cable equivalent
I/O4 -
JIS C 3312 power cable equivalent
I/O4 +
I/O3 -
14 AWG Belden 8720 equivalent
I/O3 +
Outer Diameter:
Selected Input/Output (Note) Without gland:
I/O2 -
I/O2 + ø6.5 to ø12 mm (ø0.26 to ø0.47 in.)
I/O1 - With waterproof gland (optional code EG, EG#, EU, EU#, EW):
I/O1 + For excitation cable:
Protective Grounding ø10.5 or ø11.5 mm (ø0.41 or ø0.45 in.)
(Inside and outside of the terminal box) For power and input/output cable:
F31.ai
ø7.5 to ø12 mm (ø0.30 to ø0.47 in.)
Note: Read "Functions" for the input/output signal terminals.
With plastic gland (optional code EP, EP#):
ø6 to ø12 mm (ø0.24 to ø0.47 in.)
Nominal Cross Section:
Single wire: 0.5 to 2.5 mm2
Stranded wire: 0.5 to 1.5 mm2
Excitation Cable for Submersible Use and Optional Code DHC:
Heat resistant vinyl resin sheath cable
Outer diameter ø10.5 mm (ø0.41 in.)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
75
n DIMENSIONAL DRAWINGS
(1) Integral Flowmeter, Remote Sensor
● Wafer (PFA Lining)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
Size 2.5 to 15 mm (0.1 to 0.5 in.) 56 (2.20)*1 232 (9.13)*1
AXG002 150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
AXG005 (M4) 48 (1.89)
-AA ø91 (3.58)
AXG010
48 (1.89) 113 (4.45)
AXG015 Process

ø128 (5.04)
(2.24) (1.65)(1.65)

Connection
42 42

Size Code Code


Lining Code

63 (2.48)
57
Hi

Hr
*1: This length becomes 21 mm
d)
(0.83 in.) shorter when display (ø
H1

code N is selected.

øD
63.5 (2.52)
L □72 (2.83)
□58 (2.28)
4-ø6.2 (0.24)

Ground Terminal F33.ai


(M4)
Size 25 to 125 mm (1 to 5 in.) 56 (2.20)*1 232 (9.13)*1
AXG025 150 (5.91) 68 (2.68) 83 (3.27) 25 (0.98)
Ground Terminal
AXG032 (M4) 48 (1.89)
AXG040 ø91 (3.58)
AXG050 48 (1.89) 113 (4.45)
-AA

ø128 (5.04)
AXG065
(2.24) (1.65)(1.65)
42 42

AXG080 Process
AXG100 Connection
63 (2.48)

AXG125 Code
Lining Code
57

Size Code
Hi

*1: This length becomes 21 mm


Hr

(0.83 in.) shorter when ød


H1

display code N is selected.


øD

L F34.ai

Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Size 150 to 200 mm (6 to 8 in.)
150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
AXG150 (M4)
-AA 48 (1.89)
AXG200 ø91 (3.58)
Process 48 (1.89) 113 (4.45)
ø128 (5.04)
(2.24) (1.65) (1.65)

Connection
57 42 42

Code Lifting
Size Code
Lining Code Hole*2
63 (2.48)
Hi

*1: This length øD


Hr

becomes 21 mm
(0.83 in.) shorter )
(ød
H1

when display
H3

code N is
selected.
*2: Similar design to
standardized eye
L bolt. F35.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
76
Unit: mm (approx. in.)
AA1, AA2, AJ1, AJ2 AA1, AJ1 AA2, AJ2 AA1, AJ1 AA2, AJ2
AE4 AE2 AE2 - AE2 -
Process Connection
- - - - - - - - - - - - - - AE1 -
Code
- - - - - - - - - AG1 AG1 - AG1 -
Model AP1 - AP1 - AP1 - AP1 - AP1 -
Size Code 002 005 010 015 025 032 040 050 065 080 100 125 150 150 200 200
2.5 5 10 15 25 32 40 50 65 80 100 125 150 150 200 200
Size
(0.1) (0.2) (0.4) (0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5) (6) (6) (8) (8)
Lining Code A A A A A A A A A A A A A A A A
79 79 79 79 58 68 68 78 98 118 148 198 197 197 247 247
Lay Length (*1) L
(3.11) (3.11) (3.11) (3.11) (2.30) (2.69) (2.69) (3.09) (3.87) (4.66) (5.84) (7.81) (7.74) (7.74) (9.70) (9.70)
Remote 44 44 44 44 68 73 86 99 117 129 155 183 202 202 252 252
Outer Diameter øD
(1.73) (1.73) (1.73) (1.73) (2.66) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10) (7.20) (7.94) (7.94) (9.91) (9.91)
Sensor
Lining Inner 2 5 8 13 24 29 37 49 61 73 97 121 145 145 194 194
ød
Diameter (0.09) (0.19) (0.30) (0.51) (0.93) (1.13) (1.44) (1.94) (2.40) (2.87) (3.82) (4.76) (5.72) (5.72) (7.65) (7.65)
Integral
167 167 167 167 110 116 129 148 165 175 201 230 244 262 294 312
Flowmeter Height H1
(6.57) (6.57) (6.57) (6.57) (4.33) (4.57) (5.08) (5.83) (6.50) (6.89) (7.91) (9.06) (9.62) (10.31) (11.59) (12.28)
235 235 285 285
Height H3 - - - - - - - - - - - -
(9.26) (9.26) (11.22) (11.22)
Maximum 284 284 284 284 227 233 246 265 282 292 318 347 362 380 412 430
Hr
Remote Height (11.18) (11.18) (11.18) (11.18) (8.94) (9.17) (9.69) (10.43) (11.10) (11.50) (12.52) (13.66) (14.24) (14.96) (16.21) (16.93)
Sensor Approx. Weight, 2.7 2.7 2.7 2.7 2.2 2.4 2.6 3.2 3.9 4.6 6.3 10.5 15 15 22 22
Unit: kg (lb) (*2) (6.0) (6.0) (6.0) (6.0) (4.9) (5.3) (5.7) (7.1) (8.6) (10.1) (13.9) (23.2) (33.1) (33.1) (48.6) (48.6)
Maximum 329 329 329 329 272 278 291 310 327 337 363 392 406 424 456 474
Hi
Integral Height (12.95) (12.95) (12.95) (12.95) (10.71) (10.94) (11.46) (12.20) (12.87) (13.27) (14.29) (15.43) (16.00) (16.69) (17.97) (18.66)
Flowmeter Approx. Weight, 5.3 5.3 5.3 5.3 4.8 4.9 5.1 5.7 6.4 7.2 8.8 13.1 17 17 25 25
Unit: kg (lb) (11.7) (11.7) (11.7) (11.7) (10.6) (10.8) (11.2) (12.6) (14.1) (15.9) (19.4) (28.9) (37.5) (37.5) (55.2) (55.2)
+6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
Gaskets (BSC, BSF) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thin type (GRL, GRH, +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2
GRV) (*1) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08)
Grounding rings thin type (GRL, GRH, +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8 +8
GRV) and gaskets (BSC, BSF) (*1) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31) (+0.31)
+6 +6 +6 +6
Grounding rings thick type (GRN) (*1) - - - - - - - - - - - -
(+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN) with +12 +12 +12 +12
- - - - - - - - - - - -
gaskets (BSC, BSF) (*1) (+0.47) (+0.47) (+0.47) (+0.47)
Grounding rings thick type (GRN, GRJ, +8 +8 +8 +8 +10 +10 +10 +10 +10 +10 +10 +10 +12 +12 +12 +12
GRW) with gaskets (GA, GC, GD) (*1) (+0.31) (+0.31) (+0.31) (+0.31) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47) (+0.47) (+0.47)
Grounding rings thick type (GRN, GRJ,
+14 +14 +14 +14 +16 +16 +16 +16 +16 +16 +16 +16 +18 +18 +18 +18
GRW) with gaskets (GA, GC, GD) and
(+0.55) (+0.55) (+0.55) (+0.55) (+0.63) (+0.63) (+0.63) (+0.63) (+0.63) (+0.63) (+0.63) (+0.63) (+0.71) (+0.71) (+0.71) (+0.71)
gaskets (BSC, BSF) (*1)
Grounding rings electrode type (GRP, +28 +28 +28 +28 +28 +28 +28 +28 +28 +28 +28 +28 +34 +34 +34 +34
GRT) (*1) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.34) (+1.34) (+1.34) (+1.34)
Grounding rings electrode type (GRP, +34 +34 +34 +34 +34 +34 +34 +34 +34 +34 +34 +34 +40 +40 +40 +40
GRT) and gaskets (BSC, BSF) (*1) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.57) (+1.57) (+1.57) (+1.57)
Grounding rings electrode type (GRP, GRT) +30 +30 +30 +30 +32 +32 +32 +32 +32 +32 +32 +32 +40 +40 +40 +40
with gaskets (GA, GC, GD) (*1) (+1.18) (+1.18) (+1.18) (+1.18) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.57) (+1.57) (+1.57) (+1.57)
Grounding rings electrode type (GRP, GRT)
+36 +36 +36 +36 +38 +38 +38 +38 +38 +38 +38 +38 +46 +46 +46 +46
with gaskets (GA, GC, GD) and gaskets
(+1.42) (+1.42) (+1.42) (+1.42) (+1.50) (+1.50) (+1.50) (+1.50) (+1.50) (+1.50) (+1.50) (+1.50) (+1.81) (+1.81) (+1.81) (+1.81)
(BSC, BSF) (*1)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2) and FM (Canada) Flameproof (CF2, CJ2, CT2)
Size 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200
Lining Code A A A A A A A A A A A A A A
Wafer 0.1 0.1 0.2 0.3 0.5 0.8 1.3 1.8 2 4
- - - -
Approx. Additional Weigt, Unit: kg (lb) (0.22) (0.22) (0.44) (0.66) (1.10) (1.76) (2.87) (3.97) (4.41) (8.82)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
77
● Flange (PFA Lining, excluding High Pressure Type)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
Size 2.5 to 15 mm (0.1 to 0.5 in.) 56 (2.20)*1 232 (9.13)*1
AXG002 150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
AXG005 (M4) 48 (1.89)
-A ø91 (3.58)
AXG010 48 (1.89) 113 (4.45)

ø128 (5.04)
AXG015 Process (2.24) (1.65) (1.65)
57 42 42
Connection
Size Code Code
=B, D, P Lining Code

63 (2.48)
Hi

t
N-øh

Hr

60.5 (2.38) (H2)


*1: This length becomes 21
øD
mm (0.83 in.) shorter
H1
øC
when display code N is (ød
selected. )

L θ˚

F36.ai

Ground Terminal
Size 25 to 125 mm (1 to 5 in.) (M4)
56 (2.20)*1 232 (9.13)*1
AXG025 68 (2.68) 83 (3.27) 25 (0.98)
150 (5.91) Ground Terminal
AXG032 (M4) 48 (1.89)
AXG040 ø91 (3.58)
AXG050 48 (1.89) 113 (4.45)
-A

ø128 (5.04)
(2.24) (1.65) (1.65)

AXG065
57 42 42

AXG080 Process
AXG100 Connection
63 (2.48)

AXG125 Code
Lining Code
t
Size Code
Hi

=B, C, P *1: This length becomes


Hr

(H2)

21 mm (0.83 in.) (ød)


H1

shorter when display


code N is selected. øD
øC
N-øh
L θ˚

F37.ai

Ground Terminal
Size 150 to 200 mm (6 to 8 in.) (M4)
56 (2.20)*1 232 (9.13)*1
AXG150 Ground Terminal
150 (5.91) 68 (2.68) 83 (3.27) 25 (0.98)
AXG200 -A (M4) 48 (1.89)
ø91 (3.58)
Size Code Process 48 (1.89) 113 (4.45)
ø128 (5.04)

Connection
(2.24) (1.65) (1.65)
57 42 42

=B, C, P Code
Lining Code
63 (2.48)

øD
Hi

*1: This length


(H2)

becomes 21 mm
øC
Hr

(0.83 in.) shorter



when display
H1

d)
code N is
selected.
N-øh
L θ˚

F38.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
78
Unit: mm (approx. in.)
Size 250 to 400 mm (10 to 16 in.)
AXG250 Integral Remote Integral Remote
AXG300 Flowmeter Sensor Flowmeter Sensor
-A
AXG350 Ground Terminal
AXG400 Process (M4)
Connection 56 (2.20)*1 232 (9.13)*1
Ground Terminal
Size Code Code
150 (5.91) (M4) 68 (2.68) 83 (3.27) 25 (0.98)
=B, C, P Lining Code ø91 (3.58) 48 (1.89)
48 (1.89) 113 (4.45)

ø128(5.04)
(2.24)(1.65) (1.65)
57 42 42

Eye Bolt

63 (2.48)
*1: This length øD
øC
(H2)
becomes 21
Hi

mm (0.83 in.) (ød


Hr

)
shorter when

H3
H1

display code
N is
selected.

N-øh
t θ˚
L
F39.ai

Remote Sensor
Size 500 mm (20 in.)
AXG500 -A Ground Terminal
(M4)
Process ø91 (3.58) 113 (4.45)
Size Code
Connection Eye Bolt 48 (1.89)
=B, C Code
63 (2.48)

Lining Code
(H2)

øD
Hr

(ød)
H3
H1

øC

N-øh
t θ˚

L
F40.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
79
 Flange, ASME Class 150
Unit: mm (approx. in.)
BA1
Process Connection Code - - - - - - - CA1
PA1 - PA1 - PA1 - PA1 -
Model Size Code 002 005 010 015 025 032 040 050 065 080 100 125 150 200 250 300 350 400 500
2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300 350 400 500
Size
(0.1) (0.2) (0.4) (0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5) (6) (8) (10) (12) (14) (16) (20)
Lining Code A A A A A A A A A A A A A A A A A A A
148 148 148 198 198 198 198 198 198 198 248 248 298 348 446 496 546 596 600
Lay Length (*1) (*3) L
(5.83) (5.83) (5.83) (7.80) (7.78) (7.78) (7.78) (7.78) (7.78) (7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51) (21.48) (23.44) (23.62)
Flange Outer 90 90 90 90 110 115 125 150 180 190 230 255 280 345 405 485 535 595 700
øD
Diameter (3.54) (3.54) (3.54) (3.54) (4.33) (4.53) (4.92) (5.91) (7.09) (7.48) (9.06) (10.04) (11.02) (13.58) (15.94) (19.09) (21.06) (23.43) (27.56)
Flange Thickness 19.2 19.2 19.2 16.2 18.7 19.3 20.9 22.5 25.7 27.3 27.3 27.3 30.4 33.5 35.6 37.2 40.9 42.5 48.6
t
(incl. lining flare) (0.76) (0.76) (0.76) (0.64) (0.74) (0.76) (0.82) (0.89) (1.01) (1.07) (1.07) (1.07) (1.20) (1.32) (1.40) (1.46) (1.61) (1.67) (1.91)
Lining Inner 2 5 8 13 24 29 37 49 61 73 97 121 145 194 243 292 323 374 459
ød
Diameter (0.09) (0.19) (0.30) (0.51) (0.93) (1.13) (1.44) (1.94) (2.40) (2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51) (12.73) (14.70) (18.07)
Remote Sensor Bolt 60.3 60.3 60.3 60.3 79.4 88.9 98.4 120.7 139.7 152.4 190.5 215.9 241.3 298.5 362.0 431.8 476.3 539.8 635.0
øC
Circle Diameter (2.37) (2.37) (2.37) (2.37) (3.13) (3.50) (3.87) (4.75) (5.50) (6.00) (7.50) (8.50) (9.50) (11.75) (14.25) (17.00) (18.75) (21.25) (25.00)
Integral Bolt Hole Interval θ° 45 45 45 45 45 45 45 45 45 45 22.5 22.5 22.5 22.5 15 15 15 11.25 9
15.9 15.9 15.9 15.9 15.9 15.9 15.9 19.1 19.1 19.1 19.1 22.2 22.3 22.3 25.4 25.4 28.6 28.6 31.8
Flowmeter Bolt Hole Diameter øh
(0.63) (0.63) (0.63) (0.63) (0.63) (0.63) (0.63) (0.75) (0.75) (0.75) (0.75) (0.87) (0.88) (0.88) (1.00) (1.00) (1.13) (1.13) (1.25)
Number of Bolt
N 4 4 4 4 4 4 4 4 4 4 8 8 8 8 12 12 12 16 20
Holes
164 164 164 164 135 144 149 174 198 209 239 266 283 340 401 465 512 569 689
Height H1
(6.46) (6.46) (6.46) (6.46) (5.31) (5.67) (5.87) (6.85) (7.80) (8.23) (9.41) (10.47) (11.12) (13.39) (15.78) (18.32) (20.14) (22.41) (27.12)
104 104 104 104 80 86 86 99 108 114 124 138 143 168 198 223 244 272 339
Height H2
(4.09) (4.09) (4.09) (4.09) (3.15) (3.39) (3.39) (3.90) (4.25) (4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77) (9.61) (10.70) (13.34)
456 536 595 655 760
Height H3 - - - - - - - - - - - - - -
(17.95) (21.10) (23.43) (25.79) (29.92)
Maximum 281 281 281 281
252 261 266 291
326 315 356 383 400 457 518 583 629 687 806
Hr
Height (11.06) (11.06) (11.06) (11.06)
(9.92) (10.28) (10.47) (11.46)
(12.83) (12.40) (14.02) (15.08) (15.74) (18.01) (20.40) (22.94) (24.76) (27.03) (31.74)
Remote Sensor
Approx. Weight, 3.6 3.6 3.6 3.8
4.2 4.8 5.5 7.4
13.0 10.8 18.2 22.8 31 50 79 109 136 173 233
Unit: kg (lb) (*2) (7.9) (7.9) (7.9) (8.4)
(9.3) (10.6) (12.1) (16.3)
(28.7) (23.8) (40.1) (50.3) (68.4) (110.4) (174.4) (240.6) (300.2) (381.9) (514.4)
Maximum 326 326 326 326
297 306 311 336
371 360 401 428 445 502 563 627 674 731
Hi -
Integral Height (12.83) (12.83) (12.83) (12.83)
(11.69) (12.05) (12.24) (13.23)
(14.61) (14.17) (15.79) (16.85) (17.50) (19.77) (22.16) (24.69) (26.52) (28.79)
Flowmeter Approx. Weight, 6.1 6.1 6.1 6.4
6.7 7.3 8.0 9.9
15.5 13.7 20.7 25.4 34 52 82 111 138 175
-
Unit: kg (lb) (13.5) (13.5) (13.5) (14.1)
(14.8) (16.1) (17.6) (21.8)
(34.2) (30.2) (45.6) (56.0) (75.1) (114.8) (181.0) (245.0) (304.6) (386.3)
Grounding rings thin type (GRL, GRH, GRV) +2 +2 +2 +2+2 +2 +2 +2
+2 +2 +2 +2 +2 +2 +4 +4 +4 +4
-
(*1) (+0.08) (+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16) (+0.16) (+0.16)
Grounding rings thick type (GRN, GRJ, GRW) +6 +6 +6 +6
+6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +8
- - - -
(*1) (+0.24) (+0.24) (+0.24) (+0.24)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.31)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +10 +10 +10 +10 +10
+10 +10 +10 +10 +12 +12
- - - - -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39)
(+0.39) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) - - - - - - - - - -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+28 +28 +28 +28 +29 +29 +29 +29 +29 +29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - - - - -
(+1.10) (+1.10) (+1.10) (+1.10) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +32 +32 +32 +32 +33 +33 +33 +33 +33 +33 +33 +33 +40 +40
- - - - -
with gaskets (GA, GC, GD) (*1) (+1.26) (+1.26) (+1.26) (+1.26) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2) and FM (Canada) Flameproof (CF2, CJ2, CT2)
Size 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300 350 400
Lining Code A A A A A A A A A A A A A A A A A A
Flange 0.1 0.2 0.2 0.3 0.4 0.4 0.7 0.7 3 4 8 10 18 25
- - - -
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.44) (0.44) (0.66) (0.88) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05) (39.68) (55.12)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
80
 Flange, ASME Class 300
Unit: mm (approx. in.)
BA2
Process Connection Code - - - - - - - CA2
PA2 - PA2 - PA2 - PA2
Model Size Code 002 005 010 015 025 032 040 050 065 080 100 125 150 200 250 300
2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300
Size
(0.1) (0.2) (0.4) (0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5) (6) (8) (10) (12)
Lining Code A A A A A A A A A A A A A A A A
148 148 148 198 198 198 198 198 198 198 248 248 298 348 446 496
Lay Length (*1) (*3) L
(5.83) (5.83) (5.83) (7.80) (7.78) (7.78) (7.78) (7.78) (7.78) (7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51)
Flange Outer 95 95 95 95 125 135 155 165 190 210 255 280 320 380 445 520
øD
Diameter (3.74) (3.74) (3.74) (3.74) (4.92) (5.31) (6.10) (6.50) (7.48) (8.27) (10.04) (11.02) (12.60) (14.96) (17.52) (20.47)
Flange Thickness 20.3 20.3 20.3 17.3 21.9 22.5 24.1 25.7 28.9 32.0 35.2 38.4 41.5 46.2 53.1 56.3
t
(incl. lining flare) (0.80) (0.80) (0.80) (0.68) (0.86) (0.89) (0.95) (1.01) (1.14) (1.26) (1.39) (1.51) (1.63) (1.82) (2.09) (2.22)
2 5 8 13 24 29 37 49 61 73 97 121 145 194 243 292
Lining Inner Diameter ød
(0.09) (0.19) (0.30) (0.51) (0.93) (1.13) (1.44) (1.94) (2.40) (2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51)
Remote Sensor Bolt 66.7 66.7 66.7 66.7 88.9 98.4 114.3 127.0 149.2 168.3 200.0 235.0 269.9 330.2 387.4 450.8
øC
Circle Diameter (2.63) (2.63) (2.63) (2.63) (3.50) (3.87) (4.50) (5.00) (5.87) (6.63) (7.87) (9.25) (10.63) (13.00) (15.25) (17.75)
Integral Bolt Hole Interval θ° 45 45 45 45 45 45 45 22.5 22.5 22.5 22.5 22.5 15 15 11.25 11.25
Flowmeter 15.9 15.9 15.9 15.9 19.1 19.1 22.2 19.1 22.2 22.2 22.2 22.2 22.3 25.4 28.6 31.8
Bolt Hole Diameter øh
(0.63) (0.63) (0.63) (0.63) (0.75) (0.75) (0.87) (0.75) (0.87) (0.87) (0.87) (0.87) (0.88) (1.00) (1.13) (1.25)
Number of Bolt Holes N 4 4 4 4 4 4 4 8 8 8 8 8 12 12 16 16
164 164 164 164 143 154 164 182 203 219 252 278 303 358 421 483
Height H1
(6.46) (6.46) (6.46) (6.46) (5.63) (6.06) (6.46) (7.17) (7.99) (8.62) (9.92) (10.94) (11.91) (14.08) (16.57) (19.01)
104 104 104 104 80 86 86 99 108 114 124 138 143 168 198 223
Height H2
(4.09) (4.09) (4.09) (4.09) (3.15) (3.39) (3.39) (3.90) (4.25) (4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77)
496 571
Height H3 - - - - - - - - - - - - - -
(19.53) (22.48)
Maximum 281 281 281 281 260 271 281 299 320 336 369 395 420 475 538 600
Hr
Height (11.06) (11.06) (11.06) (11.06) (10.24) (10.67) (11.06) (11.77) (12.60) (13.23) (14.53) (15.55) (16.53) (18.70) (21.19) (23.62)
Remote Sensor
Approx. Weight, 3.9 3.9 3.9 4.0 5.2 6.2 8.0 9.3 13.2 17.2 26.7 35.5 47 71 112 152
Unit: kg (lb) (*2) (8.6) (8.6) (8.6) (8.8) (11.5) (13.7) (17.6) (20.5) (29.1) (37.9) (58.9) (78.3) (103.8) (156.7) (247.2) (335.5)
Maximum 326 326 326 326 305 316 326 344 365 381 414 440 465 520 583 645
Hi
Integral Height (12.83) (12.83) (12.83) (12.83) (12.01) (12.44) (12.83) (13.54) (14.37) (15.00) (16.30) (17.32) (18.29) (20.46) (22.95) (25.38)
Flowmeter Approx. Weight, 6.5 6.5 6.5 6.6 7.8 8.8 10.5 11.8 15.7 19.7 29.2 38.0 50 74 114 155
Unit: kg (lb) (14.3) (14.3) (14.3) (14.6) (17.2) (19.4) (23.2) (26.0) (34.6) (43.4) (64.4) (83.8) (110.4) (163.4) (251.7) (342.2)
+2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16)
Grounding rings thick type (GRN, GRJ, GRW) +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
- - - -
(*1) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +12 +12
- -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) - - - - - - - - -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+28 +28 +28 +28 +29 +29 +29 +29 +29 +29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - -
(+1.10) (+1.10) (+1.10) (+1.10) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +32 +32 +32 +32 +33 +33 +33 +33 +33 +33 +33 +33 +40 +40
- -
with gaskets (GA, GC, GD) (*1) (+1.26) (+1.26) (+1.26) (+1.26) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2) and FM (Canada) Flameproof (CF2, CJ2, CT2)
Size 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300
Lining Code A A A A A A A A A A A A A A A A
Flange 0.1 0.2 0.2 0.3 0.4 0.4 0.7 0.7 3 4 8 10
- - - -
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.44) (0.44) (0.66) (0.88) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
81
 Flange, EN PN16, EN PN40
Unit: mm (approx. in.)
DE4 BE4 BE2
Process Connection
- - - - - - - - - - CE4 CE2
Code
- - - PE4 - PE4 - PE2 - PE2 -
Model Size Code 002 005 010 002 005 010 015 025 032 040 050 065 080 100 125 150 200 250 300 500
2.5 5 10 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300 500
Size
(0.1) (0.2) (0.4) (0.1) (0.2) (0.4) (0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5) (6) (8) (10) (12) (20)
Lining Code A A A A A A A A A A A A A A A A A A A A
148 148 148 148 148 148 198 198 198 198 198 198 198 248 248 298 348 446 496 600
Lay Length (*1) (*3) L
(5.83) (5.83) (5.83) (5.83) (5.83) (5.83) (7.80) (7.78) (7.78) (7.78) (7.78) (7.78) (7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51) (23.62)
Flange Outer 90 90 90 95 95 95 95 115 140 150 165 185 200 220 250 285 340 405 460 715
øD
Diameter (3.54) (3.54) (3.54) (3.74) (3.74) (3.74) (3.74) (4.53) (5.51) (5.91) (6.50) (7.28) (7.87) (8.66) (9.84) (11.22) (13.39) (15.94) (18.11) (28.15)
Flange Thickness 20.0 20.0 20.0 20.0 20.0 20.0 19.0 22.0 21.0 21.0 23.0 21.0 23.0 23.0 25.0 25.5 27.5 30.0 31.0 49.3
t
(incl. lining flare) (0.79) (0.79) (0.79) (0.79) (0.79) (0.79) (0.75) (0.87) (0.83) (0.83) (0.91) (0.83) (0.91) (0.91) (0.98) (1.00) (1.08) (1.18) (1.22) (1.94)
2 5 8 2 5 8 13 24 29 37 49 61 73 97 121 145 194 243 292 459
Lining Inner Diameter ød
Remote (0.09) (0.19) (0.30) (0.09) (0.19) (0.30) (0.51) (0.93) (1.13) (1.44) (1.94) (2.40) (2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51) (18.07)
Sensor Bolt 60 60 60 65 65 65 65 85 100 110 125 145 160 180 210 240 295 355 410 650
øC
Circle Diameter (2.36) (2.36) (2.36) (2.56) (2.56) (2.56) (2.56) (3.35) (3.94) (4.33) (4.92) (5.71) (6.30) (7.09) (8.27) (9.45) (11.61) (13.98) (16.14) (25.59)
Bolt Hole Interval θ° 45 45 45 45 45 45 45 45 45 45 45 22.5 22.5 22.5 22.5 22.5 15 15 15 9
Integral
14 14 14 14 14 14 14 14 18 18 18 18 18 18 18 22 22 26 26 33
Flowmeter Bolt Hole Diameter øh
(0.55) (0.55) (0.55) (0.55) (0.55) (0.55) (0.55) (0.55) (0.71) (0.71) (0.71) (0.71) (0.71) (0.71) (0.71) (0.87) (0.87) (1.02) (1.02) (1.30)
Number of Bolt Holes N 4 4 4 4 4 4 4 4 4 4 4 8 8 8 8 8 12 12 12 20
164 164 164 164 164 164 164 138 156 161 182 201 214 234 263 285 338 401 453 696
Height H1
(6.46) (6.46) (6.46) (6.46) (6.46) (6.46) (6.46) (5.43) (6.14) (6.34) (7.17) (7.91) (8.43) (9.21) (10.35) (11.22) (13.29) (15.78) (17.82) (27.42)
104 104 104 104 104 104 104 80 86 86 99 108 114 124 138 143 168 198 223 339
Height H2
(4.09) (4.09) (4.09) (4.09) (4.09) (4.09) (4.09) (3.15) (3.39) (3.39) (3.90) (4.25) (4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77) (13.34)
456 511 786
Height H3 - - - - - - - - - - - - - - - - -
(17.95) (20.12) (30.94)
Maximum 281 281 281 281 281 281 255 281 273 278 331299 318 351 380 402 455 518 570 814
Hr
Remote Height (11.06) (11.06) (11.06) (11.06) (11.06) (11.06) (11.06)
(10.04) (10.75) (10.94) (11.77)
(13.03) (12.52) (13.82) (14.96) (15.84) (17.91) (20.40) (22.44) (32.04)
Sensor Approx. Weight, 3.9 3.9 3.9 4.1 4.1 4.1 4.8 4.2 6.4 7.1 8.9
12.4 9.9 15.0 20.7 29 44 73 91 247
Unit: kg (lb) (*2) (8.6) (8.6) (8.6) (9.0) (9.0) (9.0) (9.3)
(10.6) (14.1) (15.7) (19.6)
(27.3) (21.8) (33.1) (45.6) (64.0) (97.1) (161.2) (200.9) (545.3)
Maximum 326 326 326 326 326 326 300 326 318 323 376344 363 396 425 447 500 563 615
Hi -
Integral Height (12.83) (12.83) (12.83) (12.83) (12.83) (12.83) (12.83)
(11.81) (12.52) (12.72) (13.54)
(14.80) (14.29) (15.59) (16.73) (17.60) (19.67) (22.16) (24.20)
Flowmeter Approx. Weight, 6.5 6.5 6.5 6.7 6.7 6.7 7.4 6.8 9.0 9.6 11.4
15.0 12.4 17.6 23.3 31 46 75 93
-
Unit: kg (lb) (14.3) (14.3) (14.3) (14.8) (14.8) (14.8) (15.0)
(16.3) (19.8) (21.2) (25.1)
(33.1) (27.3) (38.8) (51.4) (68.4) (101.6) (165.6) (205.3)
Grounding rings thin type (GRL, GRH, GRV) +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +4 +4
-
(*1) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16)
Grounding rings thick type (GRN, GRJ, +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +8
- - - - - - -
GRW) (*1) (+0.24) (+0.24) (+0.24) (+0.24)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.31)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10+10 +10 +10 +10 +12 +12
- - -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39)
(+0.39) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) - - - - - - - - - - - - -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+28 +28 +28 +28 +28 +28 +28 +29 +29 +29 +29 +29 +29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - - -
(+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +32 +32 +32 +32 +32 +32 +32 +33 +33 +33 +33 +33 +33 +33 +33 +40 +40
- - -
with gaskets (GA, GC, GD) (*1) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300
Lining Code A A A A A A A A A A A A A A A A
Flange
0.1 0.2 0.2 0.3 0.4 0.4 0.7 0.7 3 4 8 10
Approx. Additional Weight, - - - -
(0.22) (0.44) (0.44) (0.66) (0.88) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05)
Unit: kg (lb)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
82
 Flange, EN PN10, EN PN25
Unit: mm (approx. in.)
BE1, CE1
Process Connection Code BE3, PE3
PE1 -
Size Code 080 100 125 150 200 250 300 350 400 200 250 300 350 400 500
Model
80 100 125 150 200 250 300 350 400 200 250 300 350 400 500
Size
(3) (4) (5) (6) (8) (10) (12) (14) (16) (8) (10) (12) (14) (16) (20)
Lining Code A A A A A A A A A A A A A A A
198 248 248 298 348 446 496 546 596 348 446 496 546 596 600
Lay Length (*1) (*3) L
(7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51) (21.48) (23.44) (13.68) (17.54) (19.51) (21.48) (23.44) (23.62)
200 235 270 300 360 425 485 555 620 340 395 445 505 565 670
Flange Outer Diameter øD
(7.87) (9.25) (10.63) (11.81) (14.17) (16.73) (19.09) (21.85) (24.41) (13.39) (15.55) (17.52) (19.88) (22.24) (26.38)
Flange Thickness 27.0 27.0 29.0 31.5 33.5 36.0 38.0 41.5 43.5 27.5 30.0 29.0 29.5 29.5 33.3
t
(incl. lining flare) (1.06) (1.06) (1.14) (1.24) (1.32) (1.42) (1.50) (1.63) (1.71) (1.08) (1.18) (1.14) (1.16) (1.16) (1.31)
73 97 121 145 194 243 292 323 374 194 243 292 323 374 459
Lining Inner Diameter ød
(2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51) (12.73) (14.70) (7.65) (9.55) (11.51) (12.73) (14.70) (18.07)
Bolt 160 190 220 250 310 370 430 490 550 295 350 400 460 515 620
Remote Sensor øC
Circle Diameter (6.30) (7.48) (8.66) (9.84) (12.20) (14.57) (16.93) (19.29) (21.65) (11.61) (13.78) (15.75) (18.11) (20.28) (24.41)
Integral Flowmeter Bolt Hole Interval θ° 22.5 22.5 22.5 22.5 15 15 11.25 11.25 11.25 22.5 15 15 11.25 11.25 9
18 22 26 26 26 30 30 33 36 22 22 22 22 26 26
Bolt Hole Diameter øh
(0.71) (0.87) (1.02) (1.02) (1.02) (1.18) (1.18) (1.30) (1.42) (0.87) (0.87) (0.87) (0.87) (1.02) (1.02)
Number of Bolt Holes N 8 8 8 8 12 12 16 16 16 8 12 12 16 16 20
214 242 273 293 348 411 465 522 582 338 396 445 497 554 674
Height H1
(8.43) (9.53) (10.75) (11.52) (13.69) (16.18) (18.32) (20.53) (22.91) (13.29) (15.58) (17.53) (19.55) (21.82) (26.53)
114 124 138 143 168 198 223 244 272 168 198 223 244 272 339
Height H2
(4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77) (9.61) (10.70) (6.60) (7.81) (8.77) (9.61) (10.70) (13.34)
476 536 615 680 446 496 565 625 730
Height H3 - - - - - -
(18.74) (21.10) (24.21) (26.77) (17.56) (19.53) (22.24) (24.61) (28.74)
Maximum 331 359 390 410 465 528 583 639 699455 513 563 614 672 791
Hr
Height (13.03) (14.13) (15.35) (16.13) (18.30) (20.79) (22.94) (25.15) (27.52)
(17.91) (20.20) (22.15) (24.17) (26.44) (31.15)
Remote Sensor
Approx. Weight, 13.8 18.8 25.3 35 54 86 110 146 189 44 70 84 105 132 189
Unit: kg (lb) (*2) (30.42) (41.45) (55.78) (77.26) (119.21) (189.85) (242.83) (322.30) (417.22)
(97.1) (154.5) (185.4) (231.8) (291.4) (417.2)
Maximum 376 404 435 455 510 573 627 684 744500 558 607 659 716
Hi -
Height (14.80) (15.91) (17.13) (17.89) (20.06) (22.55) (24.69) (26.91) (29.28)
(19.67) (21.96) (23.91) (25.93) (28.20)
Integral Flowmeter
Approx. Weight, 16.4 21.4 27.9 38 56 89 112 148 191 47 72 87 108 135
-
Unit: kg (lb) (36.16) (47.18) (61.51) (83.89) (123.62) (196.47) (247.24) (326.71) (421.63)
(103.8) (158.9) (192.1) (238.4) (298.0)
+2 +2 +2 +2 +2 +4 +4 +2 +4 +4 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1) - - -
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16) (+0.08) (+0.16) (+0.16) (+0.16) (+0.16)
+6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +8 +6
Grounding rings thick type (GRN, GRJ, GRW) (*1) - -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
(+0.31)
Grounding rings thick type (GRN, GRJ, GRW) +12 +12 +12 +12 +12 +12
- - - - - - - - -
with gaskets (GA, GC, GD) (*1) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+34 +34 +34 +34 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - - - - - - - - -
(+13.4) (+13.4) (+13.4) (+13.4) (+13.4) (+13.4)
Grounding rings electrode type (GRP, GRT) +40 +40 +40 +40 +40 +40
- - - - - - - - -
with gaskets (GA, GC, GD) (*1) (+1.57) (+1.57) (+1.57) (+1.57) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 80 100 125 150 200 250 300 350 400
Lining Code A A A A A A A A A
Flange 0.4 0.7 0.7 3 4 8 10 18 25
Approx. Additional Weight, Unit: kg (lb) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05) (39.68) (55.12)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
83
 Flange, JIS F12
Unit: mm (approx. in.)
BG1
Process Connection Code
CG1
Size Code 080 100 125 150 200 250 300 350 400
Model
80 100 125 150 200 250 300 350 400
Size
(3) (4) (5) (6) (8) (10) (12) (14) (16)
Lining Code A A A A A A A A A
198 248 248 298 348 446 496 546 596
Lay Length (*1) (*3) L
(7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51) (21.48) (23.44)
211 238 263 290 342 410 464 530 582
Flange Outer Diameter øD
(8.31) (9.37) (10.35) (11.42) (13.46) (16.14) (18.27) (20.87) (22.91)
Flange Thickness 23.0 23.0 25.0 26.5 26.5 29.0 28.0 30.5 30.5
t
(incl. lining flare) (0.91) (0.91) (0.98) (1.04) (1.04) (1.14) (1.10) (1.20) (1.20)
73 97 121 145 194 243 292 323 374
Lining Inner Diameter ød
(2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51) (12.73) (14.70)
Remote Sensor Bolt 168 195 220 247 299 360 414 472 524
øC
Circle Diameter (6.61) (7.68) (8.66) (9.72) (11.77) (14.17) (16.30) (18.58) (20.63)
Bolt Hole Interval θ° 45 45 30 30 22.5 22.5 18 18 15
Integral Flowmeter
19 19 19 19 19 23 23 25 25
Bolt Hole Diameter øh
(0.75) (0.75) (0.75) (0.75) (0.75) (0.91) (0.91) (0.98) (0.98)
Number of Bolt Holes N 4 4 6 6 8 8 10 10 12
220 243 270 288 339 403 455 509 563
Height H1
(8.66) (9.57) (10.63) (11.32) (13.33) (15.88) (17.90) (20.04) (22.16)
114 124 138 143 168 198 223 244 272
Height H2
(4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77) (9.61) (10.70)
461 515 591 643
Height H3 - - - - -
(18.15) (20.28) (23.27) (25.31)
Maximum 337 360 387 405 456 521 572 626 680
Hr
Height (13.27) (14.17) (15.24) (15.94) (17.95) (20.50) (22.52) (24.66) (26.78)
Remote Sensor
Approx. Weight, 12.8 16.1 21.2 30 43 73 88 114 140
Unit: kg (lb) (*2) (28.2) (35.5) (46.7) (66.2) (94.9) (161.2) (194.3) (251.7) (309.1)
Maximum 382 405 432 450 501 565 617 671 725
Hi
Height (15.04) (15.94) (17.01) (17.70) (19.71) (22.26) (24.28) (26.42) (28.54)
Integral Flowmeter
Approx. Weight, 15.3 18.7 23.6 33 46 75 90 116 142
Unit: kg (lb) (33.7) (41.2) (52.0) (72.9) (101.6) (165.6) (198.7) (256.1) (313.5)
+2 +2 +2 +2 +2 +4 +4 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16) (+0.16) (+0.16)
+6 +6 +6 +6 +6 +6 +6 +6 +6
Grounding rings thick type (GRN, GRJ, GRW) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +12 +12
- - - -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - - - -
(+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +33 +33 +33 +40 +40
- - - -
with gaskets (GA, GC, GD) (*1) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 80 100 125 150 200 250 300 350 400
Lining Code A A A A A A A A A
Flange 0.4 0.7 0.7 3 4 8 10 18 25
Approx. Additional Weight, Unit: kg (lb) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05) (39.68) (55.12)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
84
 Flange, JIS 10K
Unit: mm (approx. in.)
DJ1 BJ1
Process Connection
- - - - - - - - - - CJ1
Code
- - - PJ1 - PJ1 - PJ1 - PJ1
Model Size Code 002 005 010 002 005 010 015 025 032 040 050 065 080 100 125 150 200 250 300 350 400
2.5 5 10 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300 350 400
Size
(0.1) (0.2) (0.4) (0.1) (0.2) (0.4) (0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5) (6) (8) (10) (12) (14) (16)
Lining Code A A A A A A A A A A A A A A A A A A A A A
Lay Length 148 148 148 148 148 148 198 198 198 198 198 198 198 248 248 298 348 446 496 546 596
L
(*1) (*3) (5.83) (5.83) (5.83) (5.83) (5.83) (5.83) (7.80) (7.78) (7.78) (7.78) (7.78) (7.78) (7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51) (21.48) (23.44)
Flange Outer 90 90 90 95 95 95 95 125 135 140 155 175 185 210 250 280 330 400 445 490 560
øD
Diameter (3.54) (3.54) (3.54) (3.74) (3.74) (3.74) (3.74) (4.92) (5.31) (5.51) (6.10) (6.89) (7.28) (8.27) (9.84) (11.02) (12.99) (15.75) (17.52) (19.29) (22.05)
Flange 18.0 18.0 18.0 18.0 18.0 18.0 15.0 20.0 21.0 21.0 21.0 23.0 23.0 23.0 25.0 26.5 26.5 29.0 28.0 30.5 32.5
Thickness t
(0.71) (0.71) (0.71) (0.71) (0.71) (0.71) (0.59) (0.79) (0.83) (0.83) (0.83) (0.91) (0.91) (0.91) (0.98) (1.04) (1.04) (1.14) (1.10) (1.20) (1.28)
(incl. lining flare)
Lining Inner 2 5 8 2 5 8 13 24 29 37 49 61 73 97 121 145 194 243 292 323 374
ød
Diameter (0.09) (0.19) (0.30) (0.09) (0.19) (0.30) (0.51) (0.93) (1.13) (1.44) (1.94) (2.40) (2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51) (12.73) (14.70)
Remote Bolt 65 65 65 70 70 70 70 90 100 105 120 140 150 175 210 240 290 355 400 445 510
Sensor Circle Diameter øC (2.56) (2.56) (2.56) (2.76) (2.76) (2.76) (2.76) (3.54) (3.94) (4.13) (4.72) (5.51) (5.91) (6.89) (8.27) (9.45) (11.42) (13.98) (15.75) (17.52) (20.08)
Bolt Hole
Integral θ° 45 45 45 45 45 45 45 45 45 45 45 45 22.5 22.5 22.5 22.5 15 15 11.25 11.25 11.25
Interval
Flowmeter Bolt Hole 15 15 15 15 15 15 15 19 19 19 19 19 19 19 23 23 23 25 25 25 27
øh
Diameter (0.59) (0.59) (0.59) (0.59) (0.59) (0.59) (0.59) (0.75) (0.75) (0.75) (0.75) (0.75) (0.75) (0.75) (0.91) (0.91) (0.91) (0.98) (0.98) (0.98) (1.06)
Number of Bolt
N 4 4 4 4 4 4 4 4 4 4 4 4 8 8 8 8 12 12 16 16 16
Holes
164 164 164 164 164 164 164 143 154 156 177 196 207 229 263 283 333 398 445 489 552
Height H1
(6.46) (6.46) (6.46) (6.46) (6.46) (6.46) (6.46) (5.63) (6.06) (6.14) (6.97) (7.72) (8.15) (9.02) (10.35) (11.12) (13.10) (15.68) (17.53) (19.25) (21.72)
104 104 104 104 104 104 104 80 86 86 99 108 114 124 138 143 168 198 223 244 272
Height H2
(4.09) (4.09) (4.09) (4.09) (4.09) (4.09) (4.09) (3.15) (3.39) (3.39) (3.90) (4.25) (4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77) (9.61) (10.70)
451 496 550 620
Height H3 - - - - - - - - - - - - - - - - -
(17.76) (19.53) (21.65) (24.41)
Maximum 281 281 281 281 281 281 281 260 271 273 294 313 324 346 380 400 450 516 563 606 669
Hr
Remote Height (11.06) (11.06) (11.06) (11.06) (11.06) (11.06) (11.06) (10.24) (10.67) (10.75) (11.57) (12.32) (12.76) (13.62) (14.96) (15.74) (17.71) (20.30) (22.15) (23.87) (26.34)
Sensor Approx. Weight, 3.6 3.6 3.6 3.7 3.7 3.7 3.8 4.8 5.9 6.1 7.3 9.6 10.2 13.0 19.1 27 39 67 78 95 126
Unit: kg (lb) (*2) (7.9) (7.9) (7.9) (8.2) (8.2) (8.2) (8.4) (10.6) (13.0) (13.5) (16.1) (21.2) (22.5) (28.7) (42.1) (59.6) (86.1) (147.9) (172.2) (209.7) (278.2)
Maximum 326 326 326 326 326 326 326 305 316 318 339 358 369 391 425 445 495 560 607 651 714
Hi
Integral Height (12.83) (12.83) (12.83) (12.83) (12.83) (12.83) (12.83) (12.01) (12.44) (12.52) (13.35) (14.09) (14.53) (15.39) (16.73) (17.50) (19.47) (22.06) (23.91) (25.63) (28.10)
Flowmeter Approx. Weight, 6.2 6.2 6.2 6.3 6.3 6.3 6.4 7.3 8.4 8.7 9.8 12.1 12.7 15.6 21.6 30 41 69 80 97 129
Unit: kg (lb) (13.7) (13.7) (13.7) (13.9) (13.9) (13.9) (14.1) (16.1) (18.5) (19.2) (21.6) (26.7) (28.0) (34.4) (47.6) (66.2) (90.5) (152.3) (176.6) (214.1) (284.8)
Grounding rings thin type +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +4 +4 +4 +4
(GRL, GRH, GRV) (*1) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16) (+0.16) (+0.16)
Grounding rings thick type +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
- - - - - - -
(GRN, GRJ, GRW) (*1) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type
+10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +12 +12
(GRN, GRJ, GRW) - - - -
(+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
with gaskets (GA, GC, GD) (*1)
Metal hat grounding rings +6 +6 +6 +6 +6 +6 +6 +6 +6
- - - - - - - - - - - -
(GSN, GDN) (*1) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings electrode type +28 +28 +28 +28 +28 +28 +28 +29 +29 +29 +29 +29 +29 +29 +29 +34 +34
- - - -
(GRP, GRT) (*1) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type
+32 +32 +32 +32 +32 +32 +32 +33 +33 +33 +33 +33 +33 +33 +33 +40 +40
(GRP, GRT) - - - -
(+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)
with gaskets (GA, GC, GD) (*1)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300 350 400
Lining Code A A A A A A A A A A A A A A A A A A
Flange
0.1 0.2 0.2 0.3 0.4 0.4 0.7 0.7 3 4 8 10 18 25
Approx. Additional Weight, - - - -
(0.22) (0.44) (0.44) (0.66) (0.88) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05) (39.68) (55.12)
Unit: kg (lb)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
85
 Flange, JIS 20K
Unit: mm (approx. in.)
DJ2 BJ2
Process Connection Code
- - - - - - - - - - CJ2
Size Code 002 005 010 002 005 010 015 025 032 040 050 065 080 100 125 150 200 250 300
Model
2.5 5 10 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300
Size
(0.1) (0.2) (0.4) (0.1) (0.2) (0.4) (0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5) (6) (8) (10) (12)
Lining Code A A A A A A A A A A A A A A A A A A A
148 148 148 148 148 148 198 198 198 198 198 198 198 248 248 298 348 446 496
Lay Length (*1) (*3) L
(5.83) (5.83) (5.83) (5.83) (5.83) (5.83) (7.80) (7.78) (7.78) (7.78) (7.78) (7.78) (7.78) (9.74) (9.74) (11.71) (13.68) (17.54) (19.51)
90 90 90 95 95 95 95 125 135 140 155 175 200 225 270 305 350 430 480
Flange Outer Diameter øD
(3.54) (3.54) (3.54) (3.74) (3.74) (3.74) (3.74) (4.92) (5.31) (5.51) (6.10) (6.89) (7.87) (8.86) (10.63) (12.01) (13.78) (16.93) (18.90)
Flange Thickness 18.0 18.0 18.0 20.0 20.0 20.0 17.0 22.0 23.0 23.0 23.0 25.0 27.0 29.0 31.0 32.5 34.5 39.0 40.0
t
(incl. lining flare) (0.71) (0.71) (0.71) (0.79) (0.79) (0.79) (0.67) (0.87) (0.91) (0.91) (0.91) (0.98) (1.06) (1.14) (1.22) (1.28) (1.36) (1.54) (1.57)
2 5 8 2 5 8 13 24 29 37 49 61 73 97 121 145 194 243 292
Lining Inner Diameter ød
(0.09) (0.19) (0.30) (0.09) (0.19) (0.30) (0.51) (0.93) (1.13) (1.44) (1.94) (2.40) (2.87) (3.82) (4.76) (5.72) (7.65) (9.55) (11.51)
Remote Sensor Bolt 65 65 65 70 70 70 70 90 100 105 120 140 160 185 225 260 305 380 430
øC
Circle Diameter (2.56) (2.56) (2.56) (2.76) (2.76) (2.76) (2.76) (3.54) (3.94) (4.13) (4.72) (5.51) (6.30) (7.28) (8.86) (10.24) (12.01) (14.96) (16.93)
Integral Bolt Hole Interval θ° 45 45 45 45 45 45 45 45 45 45 22.5 22.5 22.5 22.5 22.5 15 15 15 11.25
Flowmeter 15 15 15 15 15 15 15 19 19 19 19 19 23 23 25 25 25 27 27
Bolt Hole Diameter øh
(0.59) (0.59) (0.59) (0.59) (0.59) (0.59) (0.59) (0.75) (0.75) (0.75) (0.75) (0.75) (0.91) (0.91) (0.98) (0.98) (0.98) (1.06) (1.06)
Number of Bolt Holes N 4 4 4 4 4 4 4 4 4 4 8 8 8 8 8 12 12 12 16
164 164 164 164 164 164 164 143 154 156 177 196 214 237 273 295 343 413 463
Height H1
(6.46) (6.46) (6.46) (6.46) (6.46) (6.46) (6.46) (5.63) (6.06) (6.14) (6.97) (7.72) (8.43) (9.33) (10.75) (11.61) (13.49) (16.27) (18.22)
104 104 104 104 104 104 104 80 86 86 99 108 114 124 138 143 168 198 223
Height H2
(4.09) (4.09) (4.09) (4.09) (4.09) (4.09) (4.09) (3.15) (3.39) (3.39) (3.90) (4.25) (4.49) (4.88) (5.43) (5.61) (6.60) (7.81) (8.77)
481 531
Height H3 - - - - - - - - - - - - - - - - -
(18.94) (20.91)
Maximum 281 281 281 281 281 281 260281 271 273 294 313 331 354 390 412 460 531 580
Hr
Height (11.06) (11.06) (11.06) (11.06) (11.06) (11.06) (11.06)
(10.24) (10.67) (10.75) (11.57) (12.32) (13.03) (13.94) (15.35) (16.23) (18.11) (20.89) (22.84)
Remote Sensor
Approx. Weight, 3.7 3.7 3.7 3.9 3.9 3.9 4.0
5.2 6.3 6.6 7.5 9.9 13.1 17.7 26.5 36 51 90 108
Unit: kg (lb) (*2) (8.2) (8.2) (8.2) (8.6) (8.6) (8.6) (8.8)
(11.5) (13.9) (14.6) (16.5) (21.8) (28.9) (39.0) (58.4) (79.5) (112.6) (198.7) (238.4)
Maximum 326 326 326 326 326 326 305326 316 318 339 358 376 399 435 457 505 575 625
Hi
Integral Height (12.83) (12.83) (12.83) (12.83) (12.83) (12.83) (12.83)
(12.01) (12.44) (12.52) (13.35) (14.09) (14.80) (15.71) (17.13) (17.99) (19.87) (22.65) (24.60)
Flowmeter Approx. Weight, 6.3 6.3 6.3 6.5 6.5 6.5 6.6
7.7 8.8 9.2 10.0 12.5 15.6 20.2 29.1 39 53 92 111
Unit: kg (lb) (13.9) (13.9) (13.9) (14.3) (14.3) (14.3) (14.6)
(17.0) (19.4) (20.3) (22.1) (27.6) (34.4) (44.5) (64.2) (86.1) (117.0) (203.1) (245.0)
+2 +2 +2 +2 +2 +2 +2+2 +2 +2 +2 +2 +2 +2 +2 +2 +2 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16)
Grounding rings thick type (GRN, GRJ, GRW) +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
- - - - - - -
(*1) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +10 +12 +12
- -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) - - - - - - - - - - - -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+28 +28 +28 +28 +28 +28 +28 +29 +29 +29 +29 +29 +29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - -
(+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +32 +32 +32 +32 +32 +32 +32 +33 +33 +33 +33 +33 +33 +33 +33 +40 +40
- -
with gaskets (GA, GC, GD) (*1) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.26) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 2.5 5 10 15 25 32 40 50 65 80 100 125 150 200 250 300
Lining Code A A A A A A A A A A A A A A A A
Flange 0.1 0.2 0.2 0.3 0.4 0.4 0.7 0.7 3 4 8 10
- - - -
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.44) (0.44) (0.66) (0.88) (0.88) (1.54) (1.54) (6.61) (8.82) (17.64) (22.05)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
86
 Flange, JPI Class 150
Unit: mm (approx. in.)
Process Connection Code BP1
Size Code 002 005 010 015 025 040 050 080 100 150 200 250 300 350 400
Model 2.5 5 10 15 25 40 50 80 100 150 200 250 300 350 400
Size
(0.1) (0.2) (0.4) (0.5) (1) (1.5) (2) (3) (4) (6) (8) (10) (12) (14) (16)
Lining Code A A A A A A A A A A A A A A A
148 148 148 198 198 198 198 198 248 298 348 446 496 546 596
Lay Length (*1) (*3) L
(5.83) (5.83) (5.83) (7.80) (7.78) (7.78) (7.78) (7.78) (9.74) (11.71) (13.68) (17.54) (19.51) (21.48) (23.44)
90 90 90 90 110 125 150 190 230 280 345 405 485 535 595
Flange Outer Diameter øD
(3.54) (3.54) (3.54) (3.54) (4.33) (4.92) (5.91) (7.48) (9.06) (11.02) (13.58) (15.94) (19.09) (21.06) (23.43)
Flange Thickness 19.2 19.2 19.2 16.2 20.3 22.5 24.1 28.9 28.9 30.4 33.5 35.6 37.2 40.9 42.5
t
(incl. lining flare) (0.76) (0.76) (0.76) (0.64) (0.80) (0.89) (0.95) (1.14) (1.14) (1.20) (1.32) (1.40) (1.46) (1.61) (1.67)
2 5 8 13 24 37 49 73 97 145 194 243 292 323 374
Lining Inner Diameter ød
(0.09) (0.19) (0.30) (0.51) (0.93) (1.44) (1.94) (2.87) (3.82) (5.72) (7.65) (9.55) (11.51) (12.73) (14.70)
Remote Sensor Bolt 60.3 60.3 60.3 60.3 79.4 98.4 120.7 152.4 190.5 241.3 298.5 362.0 431.8 476.3 539.8
øC
Circle Diameter (2.37) (2.37) (2.37) (2.37) (3.13) (3.87) (4.75) (6.00) (7.50) (9.50) (11.75) (14.25) (17.00) (18.75) (21.25)
Integral Bolt Hole Interval θ° 45 45 45 45 45 45 45 45 22.5 22.5 22.5 15 15 15 11.25
Flowmeter 16 16 16 16 16 16 19 19 19 22 22 26 26 29 29
Bolt Hole Diameter øh
(0.63) (0.63) (0.63) (0.63) (0.63) (0.63) (0.75) (0.75) (0.75) (0.87) (0.87) (1.02) (1.02) (1.14) (1.14)
Number of Bolt Holes N 4 4 4 4 4 4 4 4 8 8 8 12 12 12 16
164 164 164 164 135 149 174 209 239 283 340 401 465 512 569
Height H1
(6.46) (6.46) (6.46) (6.46) (5.31) (5.87) (6.85) (8.23) (9.41) (11.12) (13.39) (15.78) (18.32) (20.14) (22.41)
104 104 104 104 80 86 99 114 124 143 168 198 223 244 272
Height H2
(4.09) (4.09) (4.09) (4.09) (3.15) (3.39) (3.90) (4.49) (4.88) (5.61) (6.60) (7.81) (8.77) (9.61) (10.70)
456 536 595 655
Height H3 - - - - - - - - - - -
(17.95) (21.10) (23.43) (25.79)
Maximum 281 281 281 281 252 266 291
326 356 400 457 518 583 629 687
Hr
Height (11.06) (11.06) (11.06) (11.06)
(9.92) (10.47) (11.46)
(12.83) (14.02) (15.74) (18.01) (20.40) (22.94) (24.76) (27.03)
Remote Sensor
Approx. Weight, 3.7 3.7 3.7 3.8 4.3 5.7 7.7
13.2 18.4 31 50 79 109 135 172
Unit: kg (lb) (*2) (8.2) (8.2) (8.2) (8.4)
(9.5) (12.6) (17.0)
(29.1) (40.6) (68.4) (110.4) (174.4) (240.6) (298.0) (379.7)
Maximum 326 326 326 326 297 311 336
371 401 445 502 563 627 674 731
Hi
Integral Height (12.83) (12.83) (12.83) (12.83)
(11.69) (12.24) (13.23)
(14.61) (15.79) (17.50) (19.77) (22.16) (24.69) (26.52) (28.79)
Flowmeter Approx. Weight, 6.1 6.1 6.1 6.2 6.8 8.2 10.1
15.7 20.8 34 52 81 111 138 175
Unit: kg (lb) (13.5) (13.5) (13.5) (13.7)
(15.0) (18.1) (22.3)
(34.6) (45.9) (75.1) (114.8) (178.8) (245.0) (304.6) (386.3)
+2 +2 +2 +2 +2 +2 +2+2 +2 +2 +2 +4 +4 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1)
(+0.08) (+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16) (+0.16) (+0.16)
Grounding rings thick type (GRN, GRJ, GRW) +6 +6 +6+6 +6 +6 +6 +6 +6 +6 +6
- - - -
(*1) (+0.24) (+0.24) (+0.24)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +10 +10 +10 +10
+10 +10 +12 +12
- - - -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39) (+0.39)
(+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) - - - - - - -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+28 +28 +28 +28 +29 +29 +29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - - - -
(+1.10) (+1.10) (+1.10) (+1.10) (+1.14) (+1.14) (+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +32 +32 +32 +32 +33 +33 +33 +33 +33 +40 +40
- - - -
with gaskets (GA, GC, GD) (*1) (+1.26) (+1.26) (+1.26) (+1.26) (+1.30) (+1.30) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 2.5 5 10 15 25 40 50 80 100 150 200 250 300 350 400
Lining Code A A A A A A A A A A A A A A A
Flange 0.1 0.2 0.3 0.4 0.7 3 4 8 10 18 25
- - - -
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.44) (0.66) (0.88) (1.54) (6.61) (8.82) (17.64) (22.05) (39.68) 55.12)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
87
 Flange, AS Table D
Unit: mm (approx. in.)
Process Connection Code CS1
Size Code 050 080 100 150 200 250 300 350 400
Model 50 80 100 150 200 250 300 350 400
Size
(2) (3) (4) (6) (8) (10) (12) (14) (16)
Lining Code A A A A A A A A A
198 198 248 298 348 446 496 546 596
Lay Length (*1) (*3) L
(7.78) (7.78) (9.74) (11.71) (13.68) (17.54) (19.51) (21.48) (23.44)
150 185 215 280 335 405 455 525 580
Flange Outer Diameter øD
(5.91) (7.28) (8.46) (11.02) (13.19) (15.94) (17.91) (20.67) (22.83)
Flange Thickness 13.0 15.0 15.0 17.9 17.9 21.4 24.4 27.9 27.9
t
(incl. lining flare) (0.51) (0.59) (0.59) (0.70) (0.70) (0.84) (0.96) (1.10) (1.10)
49 73 97 145 194 243 292 323 374
Lining Inner Diameter ød
(1.94) (2.87) (3.82) (5.72) (7.65) (9.55) (11.51) (12.73) (14.70)
Remote Sensor Bolt 114 146 178 235 292 356 406 470 521
øC
Circle Diameter (4.49) (5.75) (7.01) (9.25) (11.50) (14.02) (15.98) (18.50) (20.51)
Integral Bolt Hole Interval θ° 45 45 45 22.5 22.5 22.5 15 15 15
Flowmeter 18 18 18 18 18 22 22 26 26
Bolt Hole Diameter øh
(0.71) (0.71) (0.71) (0.71) (0.71) (0.87) (0.87) (1.02) (1.02)
Number of Bolt Holes N 4 4 4 8 8 8 12 12 12
174 207 232 283 335 401 450 507 562
Height H1
(6.85) (8.15) (9.13) (11.12) (13.19) (15.78) (17.73) (19.94) (22.12)
99 114 124 143 168 198 223 244 272
Height H2
(3.90) (4.49) (4.88) (5.61) (6.60) (7.81) (8.77) (9.61) (10.70)
438 497 576 631
Height H3 - - - - -
(17.26) (19.55) (22.68) (24.84)
Maximum 291 324 349 400 452 518 568 624 679
Hr
Height (11.46) (12.76) (13.74) (15.74) (17.81) (20.40) (22.34) (24.56) (26.74)
Remote Sensor
Approx. Weight, 5.5 8.7 11.8 25 37 65 80 105 131
Unit: kg (lb) (*2) (12.1) (19.2) (26.0) (55.2) (81.7) (143.5) (176.6) (231.8) (289.2)
Maximum 336 369 394 445 497 563 612 669 724
Hi
Integral Height (13.23) (14.53) (15.51) (17.50) (19.57) (22.16) (24.10) (26.32) (28.50)
Flowmeter Approx. Weight, 7.9 11.1 14.2 27 39 67 82 107 133
Unit: kg (lb) (17.4) (24.5) (31.3) (59.6) (86.1) (147.9) (181.0) (236.2) (293.6)
+2 +2 +2 +2 +2 +4 +4 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16) (+0.16) (+0.16)
+6 +6 +6 +6 +6 +6 +6 +6 +6
Grounding rings thick type (GRN, GRJ, GRW) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +12 +12
- - - -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - - - -
(+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +33 +33 +33 +40 +40
- - - -
with gaskets (GA, GC, GD) (*1) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 50 80 100 150 200 250 300 350 400
Lining Code A A A A A A A A A
Flange 0.3 0.4 0.7 3 4 8 10 18 25
Approx. Additional Weight, Unit: kg (lb) (0.66) (0.88) (1.54) (6.61) (8.82) (17.64) (22.05) (39.68) (55.12)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
88
 Flange, AS Table E
Unit: mm (approx. in.)
Process Connection Code CS2
Size Code 050 080 100 150 200 250 300
Model 50 80 100 150 200 250 300
Size
(2) (3) (4) (6) (8) (10) (12)
Lining Code A A A A A A A
198 198 248 298 348 446 496
Lay Length (*1) (*3) L
(7.78) (7.78) (9.74) (11.71) (13.68) (17.54) (19.51)
150 185 215 280 335 405 455
Flange Outer Diameter øD
(5.91) (7.28) (8.46) (11.02) (13.19) (15.94) (17.91)
Flange Thickness 15.0 16.0 18.0 21.9 23.9 27.4 30.4
t
(incl. lining flare) (0.59) (0.63) (0.71) (0.86) (0.94) (1.08) (1.20)
49 73 97 145 194 243 292
Lining Inner Diameter ød
(1.94) (2.87) (3.82) (5.72) (7.65) (9.55) (11.51)
Remote Sensor Bolt 114 146 178 235 292 356 406
øC
Circle Diameter (4.49) (5.75) (7.01) (9.25) (11.50) (14.02) (15.98)
Bolt Hole Interval θ° 45 45 22.5 22.5 22.5 15 15
Integral Flowmeter
18 18 18 22 22 22 26
Bolt Hole Diameter øh
(0.71) (0.71) (0.71) (0.87) (0.87) (0.87) (1.02)
Number of Bolt Holes N 4 4 8 8 8 12 12
174 207 232 283 335 401 450
Height H1
(6.85) (8.15) (9.13) (11.12) (13.19) (15.78) (17.73)
99 114 124 143 168 198 223
Height H2
(3.90) (4.49) (4.88) (5.61) (6.60) (7.81) (8.77)
456 506
Height H3 - - - - -
(17.95) (19.92)
Maximum 291 324 349 400 452 518 568
Hr
Height (11.46) (12.76) (13.74) (15.74) (17.81) (20.40) (22.34)
Remote Sensor
Approx. Weight, 5.9 8.9 12.5 28 42 72 89
Unit: kg (lb) (*2) (13.0) (19.6) (27.6) (61.8) (92.7) (158.9) (196.5)
Maximum 336 369 394 445 497 563 612
Hi
Height (13.23) (14.53) (15.51) (17.50) (19.57) (22.16) (24.10)
Integral Flowmeter
Approx. Weight, 8.3 11.3 15.0 30 44 74 91
Unit: kg (lb) (18.3) (24.9) (33.1) (66.2) (97.1) (163.4) (200.9)
+2 +2 +2 +2 +2 +4 +4
Grounding rings thin type (GRL, GRH, GRV) (*1)
(+0.08) (+0.08) (+0.08) (+0.08) (+0.08) (+0.16) (+0.16)
+6 +6 +6 +6 +6 +6 +6
Grounding rings thick type (GRN, GRJ, GRW) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, GRW) +10 +10 +10 +12 +12
- -
with gaskets (GA, GC, GD) (*1) (+0.39) (+0.39) (+0.39) (+0.47) (+0.47)
+6 +6 +6 +6 +6 +6
Metal hat grounding rings (GSN, GDN) (*1) -
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+29 +29 +29 +34 +34
Grounding rings electrode type (GRP, GRT) (*1) - -
(+1.14) (+1.14) (+1.14) (+1.34) (+1.34)
Grounding rings electrode type (GRP, GRT) +33 +33 +33 +40 +40
- -
with gaskets (GA, GC, GD) (*1) (+1.30) (+1.30) (+1.30) (+1.57) (+1.57)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional grounding rings with/without
gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 2.5 to 200 mm (0.1 to 8 in.): 0/-3 mm
• Size 250 to 400 mm (10 to 16 in.): 0/-5 mm

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 50 80 100 150 200 250 300
Lining Code A A A A A A A
Flange 0.3 0.4 0.7 3 4 8 10
Approx. Additional Weight, Unit: kg (lb) (0.66) (0.88) (1.54) (6.61) (8.82) (17.64) (22.05)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
89
● Flange (PFA Lining, High Pressure Type)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
Size 25 to 50 mm (1 to 2 in.) (M4) 48 (1.89)
AXG025 ø91 (3.58)
AXG040 -EA 48 (1.89) 113 (4.45)

ø128 (5.04)
AXG050 (2.24) (1.65) (1.65)
57 42 42
Process
Connection
Size Code Code
Lining Code
t
Hi

d)

Hr
*1: This length

(H2)
becomes 21 mm
(0.83 in.) shorter
H1
øD
when display
code N is øC
selected.
L N-øh
θ˚
F41.ai

Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
150 (5.91) (M4)
Size 80 to 100 mm (3 to 4 in.) 48 (1.89)
ø91 (3.58)
AXG080
-EA 48 (1.89) 113 (4.45)

ø128 (5.04)
AXG100
(2.24)(1.65)(1.65)
57 42 42

Process
Connection Eye Bolt
63 (2.48)

Size Code Code


Lining Code
Hi

*1: This length


Hr

(H2)

becomes 21 mm (ød)
H3
H1

(0.83 in.) shorter


when display øD
code N is
selected. øC

t θ˚ N-øh
L
F42.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
90
 Flange, ASME Class 600
Unit: mm (approx. in.)
Process Connection Code EA4
Size Code 025 040 050 080 100
Model 25 40 50 80 100
Size
(1) (1.5) (2) (3) (4)
Lining Code A A A A A
211 263 263 263 313
Lay Length (*1) (*3) L
(8.31) (10.35) (10.35) (10.35) (12.32)
124.0 155.5 165.1 209.6 273.1
Flange Outer Diameter øD
(4.88) (6.12) (6.50) (8.25) (10.75)
Flange Thickness 29.0 34.4 37.4 43.8 50.1
t
(incl. lining flare) (1.14) (1.35) (1.47) (1.72) (1.97)
24 29 41 64 87
Lining Inner Diameter ød
(0.93) (1.16) (1.59) (2.52) (3.43)
Remote Sensor Bolt 88.9 114.3 127.0 168.1 215.9
øC
Circle Diameter (3.50) (4.50) (5.00) (6.62) (8.50)
Bolt Hole Interval θ° 45 45 22.5 22.5 22.5
Integral Flowmeter
19.1 22.4 19.1 22.4 25.4
Bolt Hole Diameter øh
(0.75) (0.88) (0.75) (0.88) (1.00)
Number of Bolt Holes N 4 4 8 8 8
148 167 185 222 265
Height H1
(5.83) (6.57) (7.28) (8.74) (10.43)
86 90 103 117 129
Height H2
(3.38) (3.53) (4.05) (4.61) (5.07)
243 306
Height H3 - - -
(9.57) (12.05)
Maximum 265 284 302 339 382
Hr
Height (10.43) (11.18) (11.89) (13.35) (15.04)
Remote Sensor
Approx. Weight, 5.8 9.2 11.0 19.4 36.9
Unit: kg (lb) (*2) (12.8) (20.3) (24.3) (42.8) (81.4)
Maximum 310 329 347 384 427
Hi
Height (12.20) (12.95) (13.66) (15.12) (16.81)
Integral Flowmeter
Approx. Weight, 8.2 11.6 13.4 21.9 39.3
Unit: kg (lb) (18.1) (25.6) (29.5) (48.3) (86.6)

*1: The lay length “L” includes the thickness of the grounding rings (GRN) which always needs to be selected.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.
*3: The limit deviation of the lay length “L” is as follows.
• Size 25 mm (1 in.): 0/-4 mm
• Size 40 to 100 mm (1.5 to 4 in.): 0/-5 mm

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
91
● Ceramics Tube (Union Joint)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Size 2.5 to 10 mm (0.1 to 0.4 in.)
150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
AXG002
(M4) 48 (1.89)
AXG005 -GC
ø91 (3.58)
AXG010
Process 48 (1.89) 113 (4.45)

ø128 (5.04)
(2.24) (1.65) (1.65)
Connection
42 42

Size Code Code


Lining Code

63 (2.48)
57
Hi

Hr *1: This length becomes 21


H1 mm (0.83 in.) shorter when
display code N is selected.

63.5 (2.52)
L □72 (2.83)
□58 (2.28)
4-ø6.2 (0.24)

F43.ai
Unit: mm (approx. in.)
Process Connection GUN, GUR: GUW:
Code Screw Union Joint Welding Union Joint
Size Code 002 005 010 002 005 010
Model
2.5 5 10 2.5 5 10
Size
(0.1) (0.2) (0.4) (0.1) (0.2) (0.4)
Lining Code C C C C C C
Remote 130 140
Sensor Lay Length L
(5.12) (5.51)
167 167
Integral Height H1
Flowmeter (6.57) (6.57)
Maximum 284 284
Hr
Remote Height (11.18) (11.18)
Sensor Approx. Weight, 2.7 2.7
Unit: kg (lb) (*1) (6.0) (6.0)
Maximum 329 329
Hi
Integral Height (12.95) (12.95)
Flowmeter Approx. Weight, 5.2 5.2
Unit: kg (lb) (11.5) (11.5)
*1: When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Screw Union Joint Welding Union Joint


D

øA øA øB øC øD
øB øC

4(0.16) 11.5(0.45) 4(0.16) 10(0.39)


30(1.18) 35(1.38) F44.ai

Process Process Process


Connection GUN: Screw Union Joint Connection GUR: Screw Union Joint Connection GUW: Welding Union Joint
Code Code Code
Size 2.5(0.1) 5(0.2) 10(0.4) Size 2.5(0.1) 5(0.2) 10(0.4) Size 2.5(0.1) 5(0.2) 10(0.4)
øA 22(0.87) 22(0.87) 25(0.98) øA 22(0.87) 22(0.87) 25(0.98) øA 22(0.87) 22(0.87) 25(0.98)
øB 8(0.31) 8(0.31) 10(0.39) øB 8(0.31) 8(0.31) 10(0.39) øB 8(0.31) 8(0.31) 10(0.39)
øC 18.5(0.73) 18.5(0.73) 22.5(0.89) øC 18.5(0.73) 18.5(0.73) 22.5(0.89) øC 14.3(0.56) 14.3(0.56) 17.8(0.70)
D NPT1/4 NPT1/4 NPT3/8 D R1/4 R1/4 R3/8 øD 18.5(0.73) 18.5(0.73) 22.5(0.89)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
92
● Ceramics Tube (Wafer)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (1.98)
Size 15 mm (0.5 in.) (M4) 48 (1.89)
AXG015 -AC ø91 (3.58)
Process 48 (1.89) 113 (4.45)
Size Code

ø128 (5.04)
(2.24) (1.65) (1.65)
Connection 42 42
Code
Lining Code

63 (2.48)
57
Hi

Hr
*1: This length becomes 21 mm d)

H1
(0.83 in.) shorter when
display code N is selected.

øD
63.5 (2.52)
L □72 (2.83)
□58 (2.28)
4-ø6.2 (0.24)

F45.ai
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Size 25 to 100 mm (1 to 4 in.) 150 (5.91) 68 (2.68) 83 (3.27) 25 (0.98)
Ground Terminal
AXG025 (M4) 48 (1.89)
AXG040 ø91 (3.58)
AXG050 -AC 48 (1.89) 113 (4.45)

ø128 (5.04)
(2.24) (1.65) (1.65)

AXG080
42 42

Process
AXG100 Connection
Code
Size Code
63 (2.48)

Lining Code
57
Hi

Hr

*1: This length becomes 21 mm øD d)


(0.83 in.) shorter when (ø
H1

display code N is selected.

F46.ai
Size 150 to 200 mm (6 to 8 in.)
AXG150 Ground Terminal
-AC
AXG200 (M4)
Process 56 (2.20)*1 232 (9.13)*1
Connection 150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
Size Code Code (M4) 48 (1.89)
Lining Code ø91 (3.58)
48 (1.89) 113 (4.45)
ø128 (5.04)
(2.24) (1.65)(1.65)
57 42 42

63 (2.48)
Hi

Hr

*1: This length becomes øD


21 mm (0.83 in.)
H1

shorter when display )


code N is selected. (ød

F47.ai
L

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
93
Unit: mm (approx. in.)
AA1, AA2, AJ1, AJ2 AA1, AJ1 AA2, AJ2 AA1, AJ1 AA2, AJ2
Process Connection AE4 AE2 AE2 - AE2 -
Code - - - - - - - - AE1 -
- - - - AG1 AG1 - AG1 -
Model Size Code 015 025 040 050 080 100 150 150 200 200
15 25 40 50 80 100 150 150 200 200
Size
(0.5) (1) (1.5) (2) (3) (4) (6) (6) (8) (8)
Lining Code C C C C C C C C C C
79 87 100 114 154 174 226 226 296 296
Lay Length (*1) L
(3.11) (3.43) (3.94) (4.49) (6.06) (6.85) (8.90) (8.90) (11.65) (11.65)
Remote 44 67.5 86 99 129 155 214 214 264 264
Sensor Outer Diameter øD
(1.73) (2.66) (3.39) (3.90) (5.08) (6.10) (8.43) (8.43) (10.39) (10.39)
Pipe Inner 13 23 36 48 73 93 141 141 187 187
Integral ød
Flowmeter Diameter (0.51) (0.91) (1.42) (1.89) (2.87) (3.66) (5.55) (5.55) (7.36) (7.36)
167 110 129 148 175 201 255 273 305 323
Height H1
(6.57) (4.33) (5.08) (5.83) (6.89) (7.91) (10.04) (10.75) (12.02) (12.72)
Maximum 284 227 246 265 292 318 372 390 423 441
Hr
Remote Height (11.18) (8.94) (9.69) (10.43) (11.50) (12.52) (14.66) (15.35) (16.63) (17.36)
Sensor Approx. Weight, 2.7 2.7 3.6 4.5 7.2 10.1 21 21 34 34
Unit: kg (lb) (*3) (6.0) (6.0) (7.9) (9.9) (15.9) (22.3) (46.4) (46.4) (75.1) (75.1)
Maximum 329 272 291 310 337 363 417 435 467 485
Hi
Integral Height (12.95) (10.71) (11.46) (12.20) (13.27) (14.29) (16.42) (17.13) (18.39) (19.09)
Flowmeter Approx. Weight, 5.2 5.2 6.1 7.0 9.7 12.6 23 23 36 36
Unit: kg (lb) (11.5) (11.5) (13.5) (15.4) (21.4) (27.8) (50.8) (50.8) (79.5) (79.5)
+6 +6 +6 +6 +6 +6 +6 +6 +6 +6
Gaskets (BSC, BSF) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
GRW) (*1) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
Grounding rings thick type (GRN, GRJ, +12 +12 +12 +12 +12 +12 +12 +12 +12 +12
GRW) and gaskets (BSC, BSF) (*1) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47)
Grounding rings thick type (GRN, GRJ, +6 +6 +6 +6 +6 +6 +6 +6 +6 +6
GRW)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
with gaskets (GA, GC, GD, GF) (*1) (*2)
Grounding rings thick type (GRN, GRJ, +12 +12 +12 +12 +12 +12 +12 +12 +12 +12
GRW) with gaskets (GA, GC, GD, GF) and
(+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47) (+0.47)
gaskets (BSC, BSF) (*1) (*2)
Grounding rings electrode type (GRP, +28 +28 +28 +28 +28 +28 +36 +36 +36 +36
GRT) (*1) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.42) (+1.42) (+1.42) (+1.42)
Grounding rings electrode type (GRP, GRT) +34 +34 +34 +34 +34 +34 +42 +42 +42 +42
and gaskets (BSC, BSF) (*1) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.65) (+1.65) (+1.65) (+1.65)
Grounding rings electrode type (GRP, GRT) +28 +28 +28 +28 +28 +28 +36 +36 +36 +36
with gaskets (GA, GC, GD, GF) (*1) (*2) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.10) (+1.42) (+1.42) (+1.42) (+1.42)
Grounding rings electrode type (GRP, GRT) +34 +34 +34 +34 +34 +34 +42 +42 +42 +42
with gaskets (GA, GC, GD, GF) and
(+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.34) (+1.65) (+1.65) (+1.65) (+1.65)
gaskets (BSC, BSF) (*1) (*2)

*1: The lay length “L” includes the thickness of two gaskets which are supplied with the flowmeter. Be sure to always use the supplied gaskets.
Add the value above (which is the total of both ends including the supplied two gaskets) to the lay length “L” when selecting optional
grounding rings with/without gaskets.
*2: When the optional code GA, GC, GD, or GF is selected, two gaskets which are supplied with the flowmeter are changed to the gaskets
selected by the optional code.
*3: When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
94
● Hygienic Use (Clamp, PFA Lining)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Size 15 to 125 mm (0.5 to 5 in.) 150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
AXG015 (M4) 48 (1.89)
AXG025 ø91 (3.58)
48 (1.89) 113 (4.45)
AXG032

ø128 (5.04)
(2.24) (1.65) (1.65)
42 42
AXG040
AXG050 -HHA

63 (2.48)
AXG065
Process
AXG080 Connection
57

AXG100
Hi

Code
AXG125

Hr
Lining Code
Size Code
*1: This length becomes 21 mm øD )
(ød

H1
(0.83 in.) shorter when
display code N is selected.

L
F48.ai

Unit: mm (approx. in.)


HAB: Tri-Clamp (not applicable for size code 032 and 125)
Process Connection HDB: DIN 32676 Clamp
Code HKB: ISO 2852 / SMS 3016 Clamp
HJA, HJB: ISO 2852 Clamp (for JIS G3447 Piping)
Model Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
Lining Code A A A A A A A A A
166 166 166 166 176 196 216 246 316
Lay Length L
Remote (6.54) (6.54) (6.54) (6.54) (6.93) (7.72) (8.50) (9.69) (12.44)
Sensor
73 73 73 86 99 117 129 155 183
Outer Diameter øD
(2.87) (2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10) (7.20)
Integral
Flowmeter 116 116 116 129 149 166 176 202 230
Height H1
(4.57) (4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95) (9.06)
Maximum 233 233 233 246 266 283 293 319 347
Hr
Remote Height (9.17) (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56) (13.66)
Sensor Approx. Weight, 3.1 2.9 3.0 3.3 4.1 5.4 6.4 9.1 13.5
Unit: kg (lb) (*1) (6.8) (6.4) (6.6) (7.3) (9.0) (11.9) (14.1) (20.1) (29.8)
Maximum 278 278 278 291 311 328 338 364 392
Hi
Integral Height (10.94) (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33) (15.43)
Flowmeter Approx. Weight, 5.6 5.4 5.5 5.8 6.7 7.9 8.9 11.7 16.1
Unit: kg (lb) (12.4) (11.9) (12.1) (12.8) (14.8) (17.4) (19.6) (25.8) (35.5)

*1: When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2) and FM (Canada) Flameproof (CF2, CJ2, CT2)
Size 15 25 32 40 50 65 80 100 125
Lining Code A A A A A A A A A
Hygienic
0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.3 1.8
Approx. Additional Weight,
(0.22) (0.22) (0.22) (0.44) (0.66) (1.10) (1.76) (2.87) (3.97)
Unit: kg (lb)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
95
 Clamp Connection Adapter
Unit: mm (approx. in.)
Process HAB, HDB, HKB, HJA, HJB
Connection HAB: Tri-Clamp
Code
Size Code 015 025 040 050 065 080 100

øC
15 25 40 50 65 80 100
Size
(0.5) (1) (1.5) (2) (2.5) (3) (4)
70 70 83 96 114 126 152
øA
(2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98)

øA

øE
øF
øB

ød
16.0 22.2 34.6 47.6 59.5 72.3 97.0
øB
(0.63) (0.87) (1.36) (1.87) (2.34) (2.85) (3.82)
19.2 25.4 38.1 50.8 63.5 76.2 101.6
øC
(0.76) (1.00) (1.50) (2.00) (2.50) (3.00) (4.00)
15.7 22.1 34.8 47.5 60.2 72.9 97.4
ød
(0.62) (0.87) (1.37) (1.87) (2.37) (2.37) (3.83)
43.6 43.6 56.3 70.6 83.3 110.3
øE -
(1.72) (1.72) (2.22) (2.78) (3.28) (4.34)
G
25.0 50.4 50.4 64.0 77.4 91.0 118.9
øF
(0.98) (1.98) (1.98) (2.52) (3.05) (3.58) (4.68) F49.ai
50 50 50 50 50 50 50
G
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) Clamp Connection Adapter
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811
(HAB) HU HV HX HY HZ JA JB

Unit: mm (approx. in.)


Process
Connection HDB: DIN 32676 Clamp
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
70 70 70 83 96 114 126 152 180
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(3.82) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
20.0 30.0 36.0 42.0 54.0 70.0 85.0 104.0 129.0
øC
(0.79) (1.18) (1.42) (1.65) (2.13) (2.76) (3.35) (4.09) (5.08)
16.0 26.0 32.0 38.0 50.0 66.0 81.0 100.0 125.0
ød
(0.63) (1.02) (1.26) (1.50) (1.97) (2.60) (3.19) (3.94) (4.92)
27.5 43.5 43.5 43.5 56.5 83.5 97.0 110.0 146.0
øE
(1.08) (1.71) (1.71) (1.71) (2.22) (3.29) (3.82) (4.33) (5.75)
34.0 50.5 50.5 50.5 64.0 91.0 106.0 119.0 155.0
øF
(1.34) (1.99) (1.99) (1.99) (2.52) (3.58) (4.17) (4.69) (6.10)
50 50 50 50 50 50 50 50 60
G
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (2.36)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(HDB) JD JE JF JG JH JJ JK JL ZD

Unit: mm (approx. in.)


Process
Connection HKB: ISO 2852 / SMS 3016 Clamp
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
70 70 70 83 96 114 126 152 180
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
18.0 25.6 34.3 38.6 51.6 64.1 76.7 102.5 141.2
øC
(0.71) (1.01) (1.35) (1.52) (2.03) (2.52) (3.02) (4.04) (5.56)
15.2 22.6 31.3 35.6 48.6 60.3 72.9 97.6 135.7
ød
(0.60) (0.89) (1.23) (1.40) (1.91) (2.37) (2.87) (3.84) (5.34)
27.5 43.5 43.5 43.5 56.5 70.5 83.5 110.0 146.0
øE
(1.08) (1.71) (1.71) (1.71) (2.22) (2.78) (3.29) (4.33) (5.75)
34.0 50.5 50.5 50.5 64.0 77.5 91.0 119.0 155.0
øF
(1.34) (1.99) (1.99) (1.99) (2.52) (3.05) (3.58) (4.69) (6.10)
50 50 50 50 50 50 50 50 60
G
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (2.36)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(HKB) JN JP JQ JR JS JT JU JV ZE

Unit: mm (approx. in.)


Process
Connection HJA, HJB: ISO 2852 Clamp (for JIS G3447 Piping)
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
70 70 70 83 96 114 126 152 180
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
21.7 25.4 31.8 38.1 50.8 63.5 76.3 101.6 139.8
øC
(0.85) (1.00) (1.25) (1.50) (2.00) (2.50) (3.00) (4.00) (5.50)
17.5 23.0 29.4 35.7 47.8 59.5 72.3 97.6 133.8
ød
(0.69) (0.91) (1.16) (1.41) (1.88) (2.34) (2.85) (3.84) (5.27)
27.5 43.5 43.5 43.5 56.5 70.5 83.5 110.0 146.0
øE
(1.08) (1.71) (1.71) (1.71) (2.22) (2.78) (3.29) (4.33) (5.75)
34.0 50.5 50.5 50.5 64.0 77.5 91.0 119.0 155.0
øF
(1.34) (1.99) (1.99) (1.99) (2.52) (3.05) (3.58) (4.69) (6.10)
50 50 50 50 50 50 50 50 60
G
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (2.36)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(HJA) HA HB HC HD HE HF HG HH ZA
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(HJB) HK HL HM HN HP HQ HR HS ZB

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
96
● Hygienic Use (Clamp, PFA Lining) with Connection Parts for HJA and HJB (Optional code W2)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
Size 15 to 125 mm (0.5 to 5 in.) (M4) 48 (1.89)
ø91 (3.58)
AXG015
48 (1.89) 113 (4.45)
AXG025

ø128 (5.04)
AXG032 (2.24) (1.65)(1.65)
57 42 42

AXG040

63 (2.48)
AXG050 -HHA
AXG065
Process
AXG080
Hi

Connection
AXG100

Hr
Code
AXG125 *1: This length becomes 21 mm øD(ød)
Lining Code

H1
(0.83 in.) shorter when
Size Code display code N is selected.

L
F50.ai

Unit: mm (approx. in.)


Process Connection Code HJA, HJB: ISO 2852 Clamp (for JIS G3447 Piping)
Size Code 015 025 032 040 050 065 080 100 125
Model 15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
Lining Code A A A A A A A A A
204 211 204 211 221 241 261 291 374
Lay Length L
(8.03) (8.31) (8.03) (8.31) (8.70) (9.49) (10.28) (11.46) (14.72)
Remote Sensor 73 73 73 86 99 117 129 155 183
Outer Diameter øD
(2.87) (2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10) (7.20)
17.5 23.0 29.4 35.7 47.8 59.5 72.3 97.6 133.8
Integral Flowmeter Inner Diameter ød
(0.69) (0.91) (1.16) (1.41) (1.88) (2.34) (2.85) (3.84) (5.27)
116 116 116 129 149 166 176 202 230
Height H1
(4.57) (4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95) (9.06)
Maximum 233 233 233 246 266 283 293 319 347
Hr
Height (9.17) (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56) (13.66)
Remote Sensor
Approx. Weight, 3.0 2.7 2.9 3.2 3.9 5.1 5.9 8.1 12.3
Unit: kg (lb) (*1) (6.6) (6.0) (6.4) (7.1) (8.6) (11.2) (13.0) (17.9) (27.1)
Maximum 278 278 278 291 311 328 338 364 392
Hi
Height (10.94) (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33) (15.43)
Integral Flowmeter
Approx. Weight, 5.5 5.2 5.4 5.7 6.5 7.6 8.5 10.7 14.9
Unit: kg (lb) (12.1) (11.5) (11.9) (12.6) (14.3) (16.8) (18.7) (23.6) (32.9)

*1 When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 15 25 32 40 50 65 80 100 125
Lining Code A A A A A A A A A
Hygienic 0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.3 1.8
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.22) (0.22) (0.44) (0.66) (1.10) (1.76) (2.87) (3.97)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
97
● Hygienic Use (Union, PFA Lining)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Size 15 to 125 mm (0.5 to 5 in.) 150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
(M4) 48 (1.89)
AXG015
ø91 (3.58)
AXG025
48 (1.89) 113 (4.45)
AXG032

ø128 (5.04)
(2.24) (1.65) (1.65)
57 42 42
AXG040
AXG050 -HJA

63 (2.48)
AXG065
Process
AXG080 Connection
Hi

AXG100 Code
AXG125

Hr
Lining Code
*1: This length becomes 21 mm øD )
Size Code (ød

H1
(0.83 in.) shorter when
display code N is selected.

L
F51.ai

Unit: mm (approx. in.)


Process Connection Code JDB: DIN 11851 Union
Size Code 015 025 032 040 050 065 080 100 125
Model 15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
Lining Code A A A A A A A A A
166 166 166 166 176 196 236 266 326
Lay Length L
Remote Sensor (6.54) (6.54) (6.54) (6.54) (6.93) (7.72) (9.29) (10.47) (12.83)
73 73 73 86 99 117 129 155 183
Outer Diameter øD
(2.87) (2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10) (7.20)
Integral Flowmeter 116 116 116 129 149 166 176 202 230
Height H1
(4.57) (4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95) (9.06)
Maximum 233 233 233 246 266 283 293 319 347
Hr
Height (9.17) (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56) (13.66)
Remote Sensor
Approx. Weight, 3.0 3.0 3.1 3.4 4.3 5.5 6.5 9.2 14.3
Unit: kg (lb) (*1) (6.6) (6.6) (6.8) (7.5) (9.5) (12.1) (14.3) (20.3) (31.5)
Maximum 278 278 278 291 311 328 338 364 392
Hi
Height (10.94) (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33) (15.43)
Integral Flowmeter
Approx. Weight, 5.5 5.5 5.6 5.9 6.9 8.0 9.1 11.8 16.9
Unit: kg (lb) (12.1) (12.1) (12.3) (13.0) (15.2) (17.6) (20.1) (26.0) (37.3)

Unit: mm (approx. in.)


Process Connection Code JKB: ISO 2853 Union
Size Code 015 025 032 040 050 065 080 100
Model 15 25 32 40 50 65 80 100
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4)
Lining Code A A A A A A A A
166 166 166 166 176 196 216 246
Lay Length L
Remote Sensor (6.54) (6.54) (6.54) (6.54) (6.93) (7.72) (8.50) (9.69)
73 73 73 86 99 117 129 155
Outer Diameter øD
(2.87) (2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10)
Integral Flowmeter 116 116 116 129 149 166 176 202
Height H1
(4.57) (4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95)
Maximum 233 233 233 246 266 283 293 319
Hr
Height (9.17) (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56)
Remote Sensor
Approx. Weight, 3.0 3.0 3.1 3.4 4.3 5.5 6.5 9.2
Unit: kg (lb) (*1) (6.6) (6.6) (6.8) (7.5) (9.5) (12.1) (14.3) (20.3)
Maximum 278 278 278 291 311 328 338 364
Hi
Height (10.94) (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33)
Integral Flowmeter
Approx. Weight, 5.5 5.5 5.6 5.9 6.9 8.0 9.1 11.8
Unit: kg (lb) (12.1) (12.1) (12.3) (13.0) (15.2) (17.6) (20.1) (26.0)

*1: When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2) and FM (Canada) Flameproof (CF2, CJ2, CT2)
Size 15 25 32 40 50 65 80 100 125
Lining Code A A A A A A A A A
Hygienic 0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.3 1.8
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.22) (0.22) (0.44) (0.66) (1.10) (1.76) (2.87) (3.97)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
98
Unit: mm (approx. in.)
Process Connection Code JJA, JJB: ISO 2853 Union (for JIS G3447 Piping)
Size Code 025 032 040 050 065 080 100
Model 25 32 40 50 65 80 100
Size
(1) (1.25) (1.5) (2) (2.5) (3) (4)
Lining Code A A A A A A A
166 166 166 176 196 216 246
Lay Length L
Remote Sensor (6.54) (6.54) (6.54) (6.93) (7.72) (8.50) (9.69)
73 73 86 99 117 129 155
Outer Diameter øD
(2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10)
Integral Flowmeter 116 116 129 149 166 176 202
Height H1
(4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95)
Maximum 233 233 246 266 283 293 319
Hr
Height (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56)
Remote Sensor
Approx. Weight, 3.0 3.1 3.4 4.3 5.5 6.5 9.2
Unit: kg (lb) (*1) (6.6) (6.8) (7.5) (9.5) (12.1) (14.3) (20.3)
Maximum 278 278 291 311 328 338 364
Hi
Height (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33)
Integral Flowmeter
Approx. Weight, 5.5 5.6 5.9 6.9 8.0 9.1 11.8
Unit: kg (lb) (12.1) (12.3) (13.0) (15.2) (17.6) (20.1) (26.0)

Unit: mm (approx. in.)


Process Connection Code JSB: SMS 1145 Union (Open groove packing type)
Size Code 025 032 040 050 065 080 100
Model 25 32 40 50 65 80 100
Size
(1) (1.25) (1.5) (2) (2.5) (3) (4)
Lining Code A A A A A A A
166 166 166 176 196 216 276
Lay Length L
Remote Sensor (6.54) (6.54) (6.54) (6.93) (7.72) (8.50) (10.87)
73 73 86 99 117 129 155
Outer Diameter øD
(2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10)
Integral Flowmeter 116 116 129 149 166 176 202
Height H1
(4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95)
Maximum 233 233 246 266 283 293 319
Hr
Height (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56)
Remote Sensor
Approx. Weight, 3.0 3.1 3.4 4.3 5.5 6.5 9.2
Unit: kg (lb) (*1) (6.6) (6.8) (7.5) (9.5) (12.1) (14.3) (20.3)
Maximum 278 278 291 311 328 338 364
Hi
Height (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33)
Integral Flowmeter
Approx. Weight, 5.5 5.6 5.9 6.9 8.0 9.1 11.8
Unit: kg (lb) (12.1) (12.3) (13.0) (15.2) (17.6) (20.1) (26.0)

*1: When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
99
 Union Connection Adapter JDB
Unit: mm (approx. in.) G
Process Connection

øC
JDB: DIN 11851 Union
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)

øA
øB

øE
øF
ød
70 70 70 83 96 114 126 152 180
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
20.0 30.0 36.0 42.0 54.0 70.0 85.0 104.0 129.0
øC
(0.79) (1.18) (1.42) (1.65) (2.13) (2.76) (3.35) (4.09) (5.08)
16.0 26.0 32.0 38.0 50.0 66.0 81.0 100.0 125.0 H
ød
(0.63) (1.02) (1.26) (1.50) (1.97) (2.60) (3.19) (3.94) (4.92)
18.0 30.0 36.0 42.0 54.0 71.0 85.0 104.0 130.0
øE
(0.71) (1.18) (1.42) (1.65) (2.13) (2.80) (3.35) (4.09) (5.12)
øF
25.8 39.8 45.8 51.8 63.8 80.8 94.8 113.8 141.8 JKB, JJA, JJB
(1.02) (1.57) (1.80) (2.04) (2.51) (3.18) (3.73) (4.48) (5.58)
RD34 RD52 RD58 RD65 RD78 RD95 RD110 RD130 RD160
G
x 1/8" x 1/6" x 1/6" x 1/6" x 1/6" x 1/6" x 1/4" x 1/4" x 1/4"
50 50 50 50 50 50 60 60 65

øC
H
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (2.36) (2.36) (2.56)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(JDB) KR KS KT KU KV KW KX KY ZH

øA
øB

øE
ød
Unit: mm (approx. in.)
Process Connection JKB: ISO 2853 Union
Code
Size Code 015 025 032 040 050 065 080 100 F G
15 25 32 40 50 65 80 100
Size H
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4)
70 70 70 83 96 114 126 152
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) JSB
18.0 25.6 34.3 38.6 51.6 64.1 76.7 102.5
øC
(0.71) (1.01) (1.35) (1.52) (2.03) (2.52) (3.02) (4.04)
G
15.2 22.6 31.3 35.6 48.6 60.3 72.9 97.6

øC
ød
(0.60) (0.89) (1.23) (1.40) (1.91) (2.37) (2.87) (3.84)
21.2 29.2 38.2 42.7 56.2 69.9 82.6 108.7
øE
(0.83) (1.15) (1.50) (1.68) (2.21) (2.75) (3.25) (4.28)
13.5 13.5 13.5 13.5 13.5 13.5 13.5 13.5

øE
øB

ød
øA
F
(0.53) (0.53) (0.53) (0.53) (0.53) (0.53) (0.53) (0.53)
3 3 3 3 3 3 3 3
G
(0.12) (0.12) (0.12) (0.12) (0.12) (0.12) (0.12) (0.12)
H
50 50 50 50 50 50 50 50 3 (0.12)
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F
(JKB) LA LB LC LD LE LF LG LH H
Unit: mm (approx. in.) F52.ai
Process Connection
Code JJA, JJB: ISO 2853 Union (for JIS G3447 Piping) Union Connection Adapter
Size Code 025 032 040 050 065 080 100
25 32 40 50 65 80 100
Size
(1) (1.25) (1.5) (2) (2.5) (3) (4)
70 70 83 96 114 126 152
øA
(2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98)
22.2 29.4 34.6 47.6 59.5 72.3 97.0
øB
(0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82)
25.6 31.8 38.0 51.0 63.5 76.3 101.6
øC
(1.01) (1.25) (1.50) (2.01) (2.50) (3.00) (4.00)
23.0 29.4 35.6 47.8 59.5 72.3 97.6
ød
(0.91) (1.16) (1.40) (1.88) (2.34) (2.85) (3.84)
29.2 35.7 42.7 56.2 69.9 82.6 108.7
øE
(1.15) (1.41) (1.68) (2.21) (2.75) (3.25) (4.28)
13.5 10.0 13.5 13.5 13.5 13.5 18.0
F
(0.53) (0.39) (0.53) (0.53) (0.53) (0.53) (0.71)
3 2.5 3 3 3 3 3
G
(0.12) (0.10) (0.12) (0.12) (0.12) (0.12) (0.12)
50 50 50 50 50 50 50
H
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (1.97)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811
(JJA) JY JZ KA KB KC KD KE
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811
(JJB) KH KJ KK KL KM KN KP
Unit: mm (approx. in.)
Process Connection JSB: SMS 1145 Union (Open groove packing type)
Code
Size Code 025 032 040 050 065 080 100
25 32 40 50 65 80 100
Size
(1) (1.25) (1.5) (2) (2.5) (3) (4)
70 70 83 96 114 126 152
øA
(2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98)
22.2 29.4 34.6 47.6 59.5 72.3 97.0
øB
(0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82)
25.4 32.0 38.1 51.0 63.5 76.2 102.5
øC
(1.00) (1.26) (1.50) (2.01) (2.50) (3.00) (4.04)
22.5 29.6 35.5 48.5 60.5 72.9 97.6
ød
(0.89) (1.17) (1.40) (1.91) (2.38) (2.87) (3.84)
32.0 40.0 48.0 61.0 73.5 86.0 120.0
øE
(1.26) (1.57) (1.89) (2.40) (2.89) (3.39) (4.72)
11 13 15 15 19 19 30
F
(0.43) (0.51) (0.59) (0.59) (0.75) (0.75) (1.18)
RD40 RD48 RD60 RD70 RD85 RD98 RD132
G
x 1/6" x 1/6" x 1/6" x 1/6" x 1/6" x 1/6" x 1/6"
50 50 50 50 50 50 65
H
(1.97) (1.97) (1.97) (1.97) (1.97) (1.97) (2.56)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811
(JSB) LK LL LM LN LP LQ LR

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
100
● Hygienic Use (Butt Weld Joint, PFA Lining)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Ground Terminal
(M4)
56 (2.20)*1 232 (9.13)*1
Size 15 to 125 mm (0.5 to 5 in.) 150 (5.91) Ground Terminal 68 (2.68) 83 (3.27) 25 (0.98)
(M4) 48 (1.89)
AXG015 ø91 (3.58)
AXG025 48 (1.89) 113 (4.45)
AXG032

ø128 (5.04)
(2.24) (1.65) (1.65)
57 42 42
AXG040
AXG050 -HKA

63 (2.48)
AXG065
Process
AXG080 Connection
AXG100
Hi

Code
AXG125

Hr
Lining Code
*1: This length becomes 21 mm øD
Size Code (0.83 in.) shorter when (ød)

H1
display code N is selected.

L
F53.ai

Unit: mm (approx. in.)


KDB: DIN 11850 Piping Butt Weld Joint
Process Connection
KKB: ISO 2037 Piping Butt Weld Joint
Code
KJA, KJB: JIS G3447 Piping Butt Weld Joint
Size Code 015 025 032 040 050 065 080 100 125
Model
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
Lining Code A A A A A A A A A
126 126 126 126 136 156 176 206 276
Lay Length L
Remote (4.96) (4.96) (4.96) (4.96) (5.35) (6.14) (6.93) (8.11) (10.87)
Sensor 73 73 73 86 99 117 129 155 183
Outer Diameter øD
(2.87) (2.87) (2.87) (3.39) (3.90) (4.61) (5.08) (6.10) (7.20)
Integral
Flowmeter 116 116 116 129 149 166 176 202 230
Height H1
(4.57) (4.57) (4.57) (5.08) (5.87) (6.54) (6.93) (7.95) (9.06)
Maximum 233 233 233 246 266 283 293 319 347
Hr
Remote Height (9.17) (9.17) (9.17) (9.69) (10.47) (11.14) (11.54) (12.56) (13.66)
Sensor Approx. Weight, 3.0 2.7 2.9 3.2 3.9 5.1 5.9 8.1 12.3
Unit: kg (lb) (*1) (6.6) (6.0) (6.4) (7.1) (8.6) (11.2) (13.0) (17.9) (27.1)
Maximum 278 278 278 291 311 328 338 364 392
Hi
Integral Height (10.94) (10.94) (10.94) (11.46) (12.24) (12.91) (13.31) (14.33) (15.43)
Flowmeter Approx. Weight, 5.5 5.2 5.4 5.7 6.5 7.6 8.5 10.7 14.9
Unit: kg (lb) (12.1) (11.5) (11.9) (12.6) (14.3) (16.8) (18.7) (23.6) (32.9)
*1: When optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2) and FM (Canada) Flameproof (CF2, CJ2, CT2)
Size 15 25 32 40 50 65 80 100 125
Lining Code A A A A A A A A A
Hygienic 0.1 0.1 0.1 0.2 0.3 0.5 0.8 1.3 1.8
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.22) (0.22) (0.44) (0.66) (1.10) (1.76) (2.87) (3.97)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
101
 Butt Weld Joint Adapter
Unit: mm (approx. in.)
Process KDB, KKB, KJA, KJB
Connection KDB: DIN 11850 Piping Butt Weld Joint
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
70 70 70 83 96 114 126 152 180
øA

øA

øB

øC
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)

ød
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
20.0 30.0 36.0 42.0 54.0 70.0 85.0 104.0 129.0
øC
(0.79) (1.18) (1.42) (1.65) (2.13) (2.76) (3.35) (4.09) (5.08)
16.0 26.0 32.0 38.0 50.0 66.0 81.0 100.0 125.0
ød
(0.63) (1.02) (1.26) (1.50) (1.97) (2.60) (3.19) (3.94) (4.92)
30 30 30 30 30 30 30 30 40 E
E F54.ai
(1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.57)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(KDB) ND NE NF NG NH NJ NK NL ZP Butt Weld Joint Adapter

Unit: mm (approx. in.)


Process
Connection KKB: ISO 2037 Piping Butt Weld Joint
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
70 70 70 83 96 114 126 152 180
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
18.0 25.6 34.3 38.6 51.6 64.1 76.7 102.5 141.2
øC
(0.71) (1.01) (1.35) (1.52) (2.03) (2.52) (3.02) (4.04) (5.56)
15.2 22.6 31.3 35.6 48.6 60.3 72.9 97.6 135.7
ød
(0.60) (0.89) (1.23) (1.40) (1.91) (2.37) (2.87) (3.84) (5.34)
30 30 30 30 30 30 30 30 40
E
(1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.57)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(KKB) NN NP NQ NR NS NT NU NV ZQ

Unit: mm (approx. in.)


Process
Connection KJA, KJB: JIS G3447 Piping Butt Weld Joint
Code
Size Code 015 025 032 040 050 065 080 100 125
15 25 32 40 50 65 80 100 125
Size
(0.5) (1) (1.25) (1.5) (2) (2.5) (3) (4) (5)
70 70 70 83 96 114 126 152 180
øA
(2.76) (2.76) (2.76) (3.27) (3.78) (4.49) (4.96) (5.98) (7.09)
16.0 22.2 29.4 34.6 47.6 59.5 72.3 97.0 121.0
øB
(0.63) (0.87) (1.16) (1.36) (1.87) (2.34) (2.85) (3.82) (4.76)
21.7 25.4 31.8 38.1 50.8 63.5 76.3 101.6 139.8
øC
(0.85) (1.00) (1.25) (1.50) (2.00) (2.50) (3.00) (4.00) (5.50)
17.5 23.0 29.4 35.7 47.8 59.5 72.3 97.6 133.8
ød
(0.69) (0.91) (1.16) (1.41) (1.88) (2.34) (2.85) (3.84) (5.27)
30 30 30 30 30 30 30 30 40
E
(1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.18) (1.57)
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(KJA) MA MB MC MD ME MF MG MH ZL
Parts No. F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9811 F9870
(KJB) MK ML MM MN MP MQ MR MS ZM

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
102
● Replacement Model Wafer (PFA Lining)
Unit: mm (approx. in.)
Integral Remote Integral Remote
Flowmeter Sensor Flowmeter Sensor
Size 25 to 100 mm (1 to 4 in.) Ground Terminal
AXG025 (M4)
AXG040 232 (9.13)*1
AXG050 -AA…/RW/GAN 150 (5.91) 56 (2.20)*1 68 (2.68) 83 (3.27) 25 (0.98)
Ground Terminal
AXG080 (M4) 48 (1.89)
Process
AXG100 Connection ø91 (3.58)
Code 48 (1.89) 113 (4.45)
Size Code

ø128 (5.04)
(2.24) (1.65) (1.65)
Lining Code
42 42

63 (2.48)
57
Hi

Hr d)
*1: This length becomes 21 mm
(0.83 in.) shorter when display (ø
H1 code N is selected.

øD

F55.ai
L

Size 150 to 200 mm (6 to 8 in.) Ground Terminal


AXG150 (M4)
-AA…/RW/GAN 232 (9.13)*1
AXG200
150 (5.91) Ground Terminal 56 (2.20)*1 68 (2.68) 83 (3.27) 25 (0.98)
Process
(M4) 48 (1.89)
Connection ø91 (3.58)
Size Code Code
48 (1.89) 113 (4.45)
Lining Code

ø128 (5.04)
(2.24) (1.65)(1.65)
57 42 42

Lifting
Hole*2
63 (2.48)
Hi

*1: This length


becomes 21 mm øD
Hr

(0.83 in.) shorter


)
when display code (ød
H1

H3

N is selected.
*2: Similar design to
standardized eye
bolt.

F56.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
103
Unit: mm (approx. in.)
AA1, AA2, AJ1, AJ2 AA1, AJ1 AA2, AJ2 AA1, AJ1 AA2, AJ2
Process Connection Code
- - - AG1 AG1 - AG1 -
Size Code 025 040 050 080 100 150 150 200 200
Model
25 40 50 80 100 150 150 200 200
Size
(1) (1.5) (2) (3) (4) (6) (6) (8) (8)
Lining Code A A A A A A A A A
Lay Length (*1)
93 106 120 160 180 230 230 300 300
(Including The Thickness L
(3.66) (4.17) (4.72) (6.30) (7.09) (9.06) (9.06) (11.81) (11.81)
Of The Grounding Ring)
68 86 99 129 155 202 202 252 252
Outer Diameter øD
Remote Sensor (2.66) (3.39) (3.90) (5.08) (6.10) (7.94) (7.94) (9.91) (9.91)
Grounding Ring 27 40 52 81 102 147.3 147.3 198.9 198.9
Integral Flowmeter ød
Inner Diameter (1.06) (1.57) (2.05) (3.19) (4.02) (5.80) (5.80) (7.83) (7.83)
110 129 148 175 201 244 262 294 312
Height H1
(4.33) (5.08) (5.83) (6.89) (7.91) (9.62) (10.31) (11.59) (12.28)
235 235 285 285
Height H3 - - - - -
(9.26) (9.26) (11.22) (11.22)
Maximum 227 246 265 292 318 362 380 412 430
Hr
Height (8.94) (9.69) (10.43) (11.50) (12.52) (14.24) (14.96) (16.21) (16.93)
Remote Sensor
Approx. Weight, 2.9 3.8 4.9 7.0 8.8 19 19 30 30
Unit: kg (lb) (*2) (6.39) (8.38) (10.80) (15.43) (19.40) (41.89) (41.89) (66.14) (66.14)
Maximum 272 291 310 337 363 406 424 456 474
Hi
Height (10.71) (11.46) (12.20) (13.27) (14.29) (16.00) (16.69) (17.97) (18.66)
Integral Flowmeter
Approx. Weight, 5.5 6.3 7.4 9.6 11.3 21 21 33 33
Unit: kg (lb) (12.13) (13.89) (16.31) (21.16) (24.91) (46.30) (46.30) (72.75) (72.75)
+6 +6 +6 +6 +6 +6 +6 +6 +6
Gaskets (BSC, BSF) (*1)
(+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24) (+0.24)
+4 +4 +4 +4 +4 +6 +6 +6 +6
Gaskets (GA, GC, GD) (*1)
(0.16) (0.16) (0.16) (0.16) (0.16) (0.24) (0.24) (0.24) (0.24)
Gaskets (GA, GC, GD) and +10 +10 +10 +10 +10 +12 +12 +12 +12
Gaskets (BSC, BSF) (*1) (0.39) (0.39) (0.39) (0.39) (0.39) (0.47) (0.47) (0.47) (0.47)

*1: Add the value above (which is the total of both ends) to the lay length “L” when selecting optional gaskets.
*2: When submersible use or optional code DHC is selected, waterproof glands with union joints and cables are attached.
When the cable length is 30-meters, add 9.5 kg (20.9 lb) to the weight in the table.

Additional weight for FM (USA) Flameproof (FF2, FJ2, FT2)


Size 25 40 50 80 100 150 200
Lining Code A A A A A A A
Wafer 0.1 0.2 0.3 0.8 1.3 2 4
Approx. Additional Weight, Unit: kg (lb) (0.22) (0.44) (0.66) (1.76) (2.87) (4.41) (8.82)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
104
(2) AXG4A Remote Transmitter Unit: mm (approx. in.)
With Display Without Display
56 (2.20) 232 (9.13)
150 (5.91) 151 (5.94) 25 (0.98)
42
86 (3.39) (1.65) 62 (2.44) 211 (8.31)
Ground Terminal
76 (2.99) (M4) 35 (1.38) 35 (1.38) 151 (5.94) 25 (0.98)

42 (1.65)
Ground Terminal

ø128 (5.04)
201 (7.91)

(M4)

140 (5.51)
299 (11.77)

66 (2.60)

(1.65)
124 (4.88)

42
23 (0.91)
118 (4.65) 107 (4.21)
Weight: 4.4 kg (9.7 lb) Weight: 4.1 kg (9.0 lb)

(3) AX01C Magnetic Flowmeter Signal Cable


Cable Finish: Finished Unit: mm (approx. in.)
AX01C-
=B, C, D

55(2.17)
A

B
E
A

B
SA

SB

C
F

90(3.54)

90(3.54)
C

(WHITE) (BLACK) (RED)


D

(WHITE) (BLACK) (RED)


8(0.31)Max.
8(0.31)Max.
(5.91)

(5.91)
150±5

150±5
TRANSMITTER

SENSOR

*1: Size Limit Deviation for L


ø10.5(0.41)

L (Specified Length)*1×103 (Specified Length)


L Limit Deviation
20(0.79) [m] Lower Upper
1 to 9 0 +2 %
AX01C- 10 to 200 0 +1 %

Unit: mm (approx. in.)


Length
Model and Suffix Code Description
D E F G
AX01C-B 70 (2.8) +5 +5 +5 +5
0 25 (1.0) 0 50 (2.0) 0 60 (2.4) 0 For AXG1A
AX01C-C 60 (2.4) +5 +5 +5 +5
0 25 (1.0) 0 70 (2.8) 0 50 (2.0) 0 For AXG4A
AX01C-D 70 (2.8) +5 +5 +5 +5
0 25 (1.0) 0 50 (2.0) 0 60 (2.4) 0 For AXFA11

Cable Finish: Unfinished


AX01C- *2: Size Limit Deviation for L
ø10.5(0.41)

=A (Specified Length)


CAP
L Limit Deviation
[m] Lower Upper
AX01C- 1 to 9 0 +4 %
10 to 100 0 +2 %
[ L (Specified Length)*2 × 103 ] + [340 (13.39) (Length for Cable Finish)]
101 to 200 0 +1 %
F57.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
105
(4) Flameproof Packing Adapter (Optional code V5#: #=1 to 5)

Unit: mm ([ ]: approx.inch)
32 [1.26]
M20x1.5
Flameproof gland (Sensor side)
O-ring

16 [0.63]
Washer
Rubber packing (See the left figure.)

øD O-ring
ød Washer
Hexagon socket set screw
(95) [(3.74)]

Gland
Cross-sectioned pan head screw
L

(12 to 15) [(0.47 to 0.59)]

Clamp
Union cover
Rubber packing O-ring

Union coupling

G1/2 32 [1.26]

34 [1.34]

Unit: mm ([ ]: approx.inch)
Dimensions of rubber packing (before compression) Identification Cable outer diameter
mark of
L øD ød rubber packing Min. Max.
20 [0.79] ø20 [0.79] ø10 [0.39] ø10 [0.39] ø8.0 [0.31] ø10.0 [0.39]

20 [0.79] ø20 [0.79] ø12 [0.47] ø12 [0.47] ø10.0 [0.39] ø12.0 [0.47]
F58.ai

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
106
(5) Mounting bolts
● Optional code BSC, BSF
 PFA Lining, JIS 10K Wafer Unit: mm (approx.inch)
Optional code (Grounding Devices)
Without Grounding ring, /GRL, /GRH,
/GRP, /GRT /GAN
Size /GRV, /GRN, /GRJ, /GRW
Nominal Bolt Length of Nominal Bolt Length of Nominal Bolt Length of
Diameter Through-bolt Diameter Through-bolt Diameter Through-bolt
2, 5, 10, 15
M12 160 (6.30) M12 180 (7.09) – –
(0.1, 0.2, 0.4, 0.5)
25 (1) M16 155 (6.10) M16 200 (7.87) M16 200 (7.87)
32 (1.25) M16 155 (6.10) M16 190 (7.48) – –
40 (1.5) M16 175 (6.89) M16 175 (6.89) M16 200 (7.87)
50 (2) M16 185 (7.28) M16 220 (8.66) M16 220 (8.66)
65 (2.5) M16 190 (7.48) M16 220 (8.66) – –
80 (3) M16 220 (8.66) M16 245 (9.65) M16 255 (10.04)
100 (4) M16 255 (10.04) M16 275 (10.83) M16 280 (11.02)
125 (5) M20 316 (12.44) M20 340 (13.39) – –
150 (6) M20 340 (13.39) M20 340 (13.39) M20 340 (13.39)
200 (8) M20 410 (16.14) M20 410 (16.14) M20 410 (16.14)

 PFA Lining, JIS 20K Wafer Unit: mm (approx.inch)


Optional code (Grounding Devices)
Without Grounding ring, /GRL, /GRH,
/GRP, /GRT /GAN
Size /GRV, /GRN, /GRJ, /GRW
Nominal Bolt Length of Nominal Bolt Length of Nominal Bolt Length of
Diameter Through-bolt Diameter Through-bolt Diameter Through-bolt
2, 5, 10, 15
M12 160 (6.30) M12 180 (7.09) – –
(0.1, 0.2, 0.4, 0.5)
25 (1) M16 155 (6.10) M16 180 (7.09) M16 180 (7.09)
32 (1.25) M16 175 (6.89) M16 190 (7.48) – –
40 (1.5) M16 175 (6.89) M16 190 (7.48) M16 200 (7.87)
50 (2) M16 185 (7.28) M16 220 (8.66) M16 220 (8.66)
65 (2.5) M16 220 (8.66) M16 220 (8.66) – –
80 (3) M20 260 (10.24) M20 260 (10.24) M20 295 (11.61)
100 (4) M20 271 (10.67) M20 295 (11.61) M20 295 (11.61)
125 (5) M22 330 (12.99) M22 360 (14.17) – –
150 (6) M22 360 (14.17) M22 360 (14.17) M22 360 (14.17)
200 (8) M22 435 (17.13) M22 435 (17.13) M22 435 (17.13)

 PFA Lining, ASME Class 150 Wafer Unit: mm (approx.inch)


Optional code (Grounding Devices)
Without Grounding ring, /GRL, /GRH,
/GRP, /GRT /GAN
Size /GRV, /GRN, /GRJ, /GRW
Nominal Bolt Length of Nominal Bolt Length of Nominal Bolt Length of
Diameter Through-bolt Diameter Through-bolt Diameter Through-bolt
2, 5, 10, 15
1/2UNC 155 (6.10) 1/2UNC 190 (7.48) – –
(0.1, 0.2, 0.4, 0.5)
25 (1) 1/2UNC 155 (6.10) 1/2UNC 165 (6.50) 1/2UNC 190 (7.48)
32 (1.25) 1/2UNC 160 (6.30) 1/2UNC 180 (7.09) – –
40 (1.5) 1/2UNC 160 (6.30) 1/2UNC 180 (7.09) 1/2UNC 190 (7.48)
50 (2) 5/8UNC 200 (7.87) 5/8UNC 200 (7.87) 5/8UNC 240 (9.45)
65 (2.5) 5/8UNC 230 (9.06) 5/8UNC 230 (9.06) – –
80 (3) 5/8UNC 230 (9.06) 5/8UNC 250 (9.84) 5/8UNC 265 (10.43)
100 (4) 5/8UNC 265 (10.43) 5/8UNC 280 (11.02) 5/8UNC 290 (11.42)
125 (5) 3/4UNC 345 (13.58) 3/4UNC 345 (13.58) – –
150 (6) 3/4UNC 345 (13.58) 3/4UNC 345 (13.58) 3/4UNC 345 (13.58)
200 (8) 3/4UNC 420 (16.54) 3/4UNC 420 (16.54) 3/4UNC 420 (16.54)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
107
 Ceramics Tube, JIS 10K Wafer Unit: mm (approx.inch)
Optional code (Grounding Devices)
Without Grounding ring, /GRL, /GRH,
/GRP, /GRT
Size /GRV, /GRN, /GRJ, /GRW
Nominal Bolt Length of Nominal Bolt Length of
Diameter Through-bolt Diameter Through-bolt
15 (0.5) M12 160 (6.30) M12 180 (7.09)
25 (1) M16 200 (7.87) M16 200 (7.87)
40 (1.5) M16 200 (7.87) M16 220 (8.66)
50 (2) M16 220 (8.66) M16 255 (10.04)
80 (3) M16 255 (10.04) M16 280 (11.02)
100 (4) M16 280 (11.02) M16 300 (11.81)
150 (6) M20 340 (13.39) M20 370 (14.57)
200 (8) M20 410 (16.14) M20 440 (17.32)

 Ceramics Tube, JIS 20K Wafer Unit: mm (approx.inch)


Optional code (Grounding Devices)
Without Grounding ring, /GRL, /GRH,
/GRP, /GRT
Size /GRV, /GRN, /GRJ, /GRW
Nominal Bolt Length of Nominal Bolt Length of
Diameter Through-bolt Diameter Through-bolt
15 (0.5) M12 160 (6.30) M12 180 (7.09)
25 (1) M16 180 (7.09) M16 200 (7.87)
40 (1.5) M16 200 (7.87) M16 220 (8.66)
50 (2) M16 220 (8.66) M16 255 (10.04)
80 (3) M20 295 (11.61) M20 295 (11.61)
100 (4) M20 295 (11.61) M20 340 (13.39)
150 (6) M22 360 (14.17) M22 390 (15.35)
200 (8) M22 435 (17.13) M22 465 (18.31)

 Ceramics Tube, ASME Class 150 Wafer Unit: mm (approx.inch)


Optional code (Grounding Devices)
Without Grounding ring, /GRL, /GRH,
/GRP, /GRT
Size /GRV, /GRN, /GRJ, /GRW
Nominal Bolt Length of Nominal Bolt Length of
Diameter Through-bolt Diameter Through-bolt
15 (0.5) 1/2UNC 155 (6.10) 1/2UNC 190 (7.48)
25 (1) 1/2UNC 190 (7.48) 1/2UNC 190 (7.48)
40 (1.5) 1/2UNC 190 (7.48) 1/2UNC 210 (8.27)
50 (2) 5/8UNC 240 (9.45) 5/8UNC 240 (9.45)
80 (3) 5/8UNC 265 (10.43) 5/8UNC 285 (11.22)
100 (4) 5/8UNC 290 (11.42) 5/8UNC 305 (12.01)
150 (6) 3/4UNC 345 (13.58) 3/4UNC 375 (14.76)
200 (8) 3/4UNC 420 (16.54) 3/4UNC 450 (17.72)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
108
● Dedicated mouonting bolt (Size 50 mm / 2 in, Submersibe, JIS 20K Wafer only)

ø12.6
M16 M16
F59.ai

Unit: mm (approx.inch)
Length of Length of bolt
Nominal Bolt Bolt Diameter
Optional code (Grounding Devices) Through-bolt without Screw
Diameter without Screw
L A
Without Grounding ring,
/GRL,/GRH,/GRV, M16 185 (7.28) 100 (3.94) 12.6 (0.50)
/GRN,/GRJ,/GRW
/GRP,/GRT, /GAN M16 220 (8.66) 120 (4.72) 12.6 (0.50)

(6) Limit Deviation


Unless otherwise specified, size limit deviation in the drawings are as shown in the following table.
General limit deviation in the dimensional outline drawing.
Unit: mm (approx. in.)
Category of basic size Category of basic size
Limit deviation Limit deviation
Above Equal or below Above Equal or below
3 (0.12) ±0.7 (±0.03) 500 (19.69) 630 (24.80) ±5.5 (±0.22)
3 (0.12) 6 (0.24) ±0.9 (±0.04) 630 (24.80) 800 (31.50) ±6.25 (±0.25)
6 (0.24) 10 (0.39) ±1.1 (±0.04) 800 (31.50) 1000 (39.37) ±7.0 (±0.28)
10 (0.39) 18 (0.71) ±1.35 (±0.05) 1000 (39.37) 1250 (49.21) ±8.25 (±0.32)
18 (0.71) 30 (1.18) ±1.65 (±0.06) 1250 (49.21) 1600 (62.99) ±9.75 (±0.38)
30 (1.18) 50 (1.97) ±1.95 (±0.08) 1600 (62.99) 2000 (78.74) ±11.5 (±0.45)
50 (1.97) 80 (3.15) ±2.3 (±0.09) 2000 (78.74) 2500 (98.43) ±14.0 (±0.55)
80 (3.15) 120 (4.72) ±2.7 (±0.11) 2500 (98.43) 3150 (124.02) ±16.5 (±0.65)
120 (4.72) 180 (7.09) ±3.15 (±0.12)
180 (7.09) 250 (9.84) ±3.6 (±0.14)
250 (9.84) 315 (12.40) ±4.05 (±0.16)
315 (12.40) 400 (15.75) ±4.45 (±0.18)
400 (15.75) 500 (19.69) ±4.85 (±0.19)
Remarks: The numeric is based on criteria of standard tolerance grade IT18 in JIS B 0401-1.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
109
n SIZING DATA
SI Units Size: mm * Measurable flow velocity is from 0 m/s.

0
0
5

40 0
0

0
0
0
0
5
65
32
25

80

20
40

50

25
2.

35
30

50
15
10
12
5

15
10
10.0

5.0

Flow velocity
(m/s)
1.0

0.5

0.3

0.1
0.001 0.01 0.1 1 10 100 1,000 10,000
Flow rate (m3/h)

English Units Size: inch


* Measurable flow velocity is from 0 ft/s.

5
0.1

0.2

0.4

0.5

1.2
1.5

2.5

10
12
14
16
20
1

3
4
5
6

8
33
Flow velocity
(ft/s)

10

5.0

2.0

1.0

0.33
0.001 0.01 0.1 1.0 10 100 1,000 10,000 100,000
F60.ai
Flow rate (GPM)

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
110
n ORDERING INFORMATION Tag No. can be "described on the nameplate and
Note 1: W hen ordering, the span flow rate, unit, stainless steel tag plate (optional code SCT)" and
output pulse weight, and totalizer display "set to the memory in the transmitter". Refer to the
pulse weight can be specified. These table below for the item to be specified.
parameters will be set before shipment. Described/ Setting Items to be Maximum
In the case of remote type, specify Destination Specified Number of Characters
combination information of sensor and • Name plate
• Stainless steel tag
transmitter. plate (Optional
30 (*)
These parameters will be set in the code SCT)
combined transmitter. TAG NO 30 (*)
When ordering of a remote sensor alone There are restrictions
or a remote transmitter alone, these • Amplifier memory on the write destination
(Integral flowmeter parameters. Read the
parameters cannot be specified. and remote next table.
Custom configuration request is necessary transmitter) SOFTWARE TAG
Read the
for setting these parameters out of regular (Overrides "TAG
next table
setting range. NO" designation)
Note 2: Some options, if ordered, require the *: For AXFA11G remote transmitter, the maximum number
relevant specifications to be input when of characters for "TAG NO" is 16.
ordering.
For integral flowmeter and remote transmitter, the
Note 3: For AXG4A FOUNDATION Fieldbus characters specified by "TAG NO" are also written
type remote transmitter, read general to the memory (parameter) in the amplifier. If it is
specifications (GS 01E21F02-01EN). necessary to specify a different tag number only for
For AXG4A EtherNet/IP type remote the amplifier memory, specify "SOFTWARE TAG".
transmitter, read general specifications It is also possible to specify only "SOFTWARE
(GS 01E21F02-02EN) TAG". Names of the parameter to be written and the
For AXG4A PROFIBUS PA type remote maximum number of characters are as shown in the
transmitter, read general specifications table below. If the number of specified characters
(GS 01E21F02-03EN). exceed the maximum number, the characters from
For AXG1A remote transmitter, read general the beginning up to the maximum number is written.
specifications (GS 01E22C01-01EN).
For AXFA11G remote transmitter, read Tag No. in Amplifier Memory
general specifications (GS 01E20C01-01E). Items to be Parameter
Maximum
Communication Number of
The contents and conditions of ordering Specified Name
Characters
informations are different. BRAIN TAG NO 16
Long Tag 32 (*)
HART
1. Model, Suffix Code and Optional Code Tag 8
TAG NO Long Tag 32
2. Combination or
Modbus
Tag 16
This is necessary when ordering combination SOFTWARE FOUNDATION
TAG PDTag 32
of remote sensor and transmitter. Specify the Fieldbus
PROFIBUS PA PB.TAG_DESC 32
combination of a sensor and a transmitter one Long Tag 32
by one by their model name, specification code, EtherNet/IP
Tag 16
or Tag No. etc. On the nameplate of each sensor
*: For AXFA11G remote transmitter, the maximum number
and transmitter, the serial number of the specified of characters for "TAG NO" is 16. And as its HART
combination partner is described when shipped. protocol is HART 5, the "Long Tag" is not available.
3. Tag No.
The Tag No. can be specified by a combination of 4. Range and Unit of Flowrate Span
the characters shown in the following table. Specify the range of span flow rate in the range of 0.0001
to 999999000000.0000 (the number of significant
Hyphen-
-
minus
. Period Space (*1) digits in operation is the upper six digits). Up to four
_ Underscore = Equal sign + Plus sign
digits below the decimal point that can be specified
Symbol (by 0.0001 unit). However, if the transmitter is BRAIN
Left round Right round
/ Slash (
bracket
)
bracket communication type, specify so that it is within the
Exclamation
range of 0.0001 to 32000, it is up to four digits below
: Colon # Hash mark ! the decimal point when it is included, and the numerical
mark
Number 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 value excluding the decimal point is within 32000.
Uppercase A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, Specify units in the unit described in "Flow
letter U, V, W, X, Y, Z Calculation Function". This span flow rate is set to
Lowercase a, b, c, d, e, f, g, h, i, j, k, l, m, n, o, p, q, r, s, t, u, v, w, the positive first range. Be sure to specify the range
letter (*2) x, y, z and unit of flowrate span when selecting the Mass
*1: Leading and trailing space characters are deleted and left- Unit Setting (optional code MU), Specified Span Five-
justified, then printed on the name plate/ tag plate and written point Calibration (optional code SC), ISO/IEC 17025
to the amplifier memory.
calibration (Specified span, 2 points) (Optional code
*2: When Communication and I/O code J# (HART
communication) is specified, the lowercase letters are
L11), or ISO/IEC 17025 calibration (Specified span,
converted to uppercase and written to the parameter “Tag”. 4 points) (Optional code L12). When selecting the
For parameter “Long Tag”, they are written in lowercase as is. NAMUR NE21 (optional code E21), specify the span
flow rate of 0.5 m/s or more in terms of flow velocity.
All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
111
Unless specified, it is set as the following when (2) C
 ombined with AXG1A Remote Transmitter
shipped. SI Units (Size: mm, Flow rate: m3/h)
• Integral Flowmeter, or combined with AXG4A or Size
0 to Min. Span 0 to Min. Span 0 to Max. Span
Flow Rate Flow Rate Flow Rate
AXG1A Remote Transmitter span flow rate (unit (mm)
m3/h (0.1 m/s) m3/h (0.5 m/s) m3/h (10 m/s)
m3/h) equivalent to flow velocity 1 m/s 2.5 0 to 0.0018 0 to 0.0089 0 to 0.1767
• Combined with AXFA11 Remote Transmitter flow 5 0 to 0.0071 0 to 0.0354 0 to 0.7068
velocity 1 m/s 10 0 to 0.0283 0 to 0.1414 0 to 2.8274
The measurement flow range (minimum and 15 0 to 0.0637 0 to 0.3181 0 to 6.3617
maximum of span flow rate) is shown below (in the 25 0 to 0.1768 0 to 0.8836 0 to 17.6714
case of flow rate unit m3/h and GPM). Specify the 32 0 to 0.2896 0 to 1.4477 0 to 28.9529
span flow within this range. The range specifying 40 0 to 0.4524 0 to 2.2620 0 to 45.2389
50 0 to 0.7069 0 to 3.5343 0 to 70.6858
different unit must also fall into the same flow rate (flow
65 0 to 1.1946 0 to 5.9730 0 to 119.459
velocity) range after conversion. 80 0 to 1.8096 0 to 9.0478 0 to 180.955
100 0 to 2.8275 0 to 14.1372 0 to 282.743
Measurable Flow Rate Range 125 0 to 4.4179 0 to 22.0894 0 to 441.786
(1) Integral Flowmeter, or combined with AXG4A 150 0 to 6.3618 0 to 31.8087 0 to 636.172
Remote Transmitter 200 0 to 11.3098 0 to 56.5487 0 to 1130.97
SI Units (Size: mm, Flow rate: m3/h) 250 0 to 17.6715 0 to 88.3573 0 to 1767.14
0 to Min. Span 0 to Min. Span 0 to Max. Span 300 0 to 25.4470 0 to 127.235 0 to 2544.69
Size 350 0 to 34.6361 0 to 173.181 0 to 3463.60
Flow Rate Flow Rate Flow Rate
(mm) 400 0 to 45.2390 0 to 226.195 0 to 4523.89
m3/h (0.1 m/s) m3/h (0.5 m/s) m3/h (10 m/s)
2.5 0 to 0.0018 0 to 0.0089 0 to 0.1767 500 0 to 70.69 0 to 353 0 to 7068
5 0 to 0.0071 0 to 0.0354 0 to 0.7068 English Units (Size: in., Flow rate: GPM)
10 0 to 0.0283 0 to 0.1414 0 to 2.8274
0 to Min. Span 0 to Min. Span 0 to Max. Span
15 0 to 0.0637 0 to 0.3181 0 to 6.3617 Size
Flow Rate Flow Rate Flow Rate
25 0 to 0.1768 0 to 0.8836 0 to 17.6714 (in.)
GPM (0.33 ft/s) GPM (1.64 ft/s) GPM (33 ft/s)
32 0 to 0.2896 0 to 1.4477 0 to 28.9529
0.1 0 to 0.0078 0 to 0.0389 0 to 0.7780
40 0 to 0.4524 0 to 2.2620 0 to 45.2389
0.2 0 to 0.0312 0 to 0.1557 0 to 3.1122
50 0 to 0.7069 0 to 3.5343 0 to 70.6858
0.4 0 to 0.1245 0 to 0.6225 0 to 12.4488
65 0 to 1.1946 0 to 5.9730 0 to 119.459
0.5 0 to 0.2801 0 to 1.4005 0 to 28.0098
80 0 to 1.8096 0 to 9.0478 0 to 180.955
1 0 to 0.7781 0 to 3.8903 0 to 77.8050
100 0 to 2.8275 0 to 14.1372 0 to 282.743
1.25 0 to 1.2748 0 to 6.3738 0 to 127.475
125 0 to 4.4179 0 to 22.0894 0 to 441.786
1.5 0 to 1.9919 0 to 9.9591 0 to 199.181
150 0 to 6.3618 0 to 31.8087 0 to 636.172
2 0 to 3.1123 0 to 15.5611 0 to 311.220
200 0 to 11.3098 0 to 56.5487 0 to 1130.97
2.5 0 to 5.2597 0 to 26.2982 0 to 525.962
250 0 to 17.6715 0 to 88.3573 0 to 1767.14
3 0 to 7.9673 0 to 39.8363 0 to 796.724
300 0 to 25.4470 0 to 127.235 0 to 2544.69
4 0 to 12.4489 0 to 62.2441 0 to 1244.88
350 0 to 34.6361 0 to 173.181 0 to 3463.60
5 0 to 19.4513 0 to 97.2564 0 to 1945.12
400 0 to 45.2390 0 to 226.195 0 to 4523.89
6 0 to 28.0099 0 to 140.049 0 to 2800.98
English Units (Size: in., Flow rate: GPM) 8 0 to 49.7953 0 to 248.977 0 to 4979.52
0 to Min. Span 0 to Min. Span 0 to Max. Span 10 0 to 77.8051 0 to 389.026 0 to 7780.5
Size 12 0 to 112.040 0 to 560.197 0 to 11203.9
Flow Rate Flow Rate Flow Rate
(in.) 14 0 to 152.498 0 to 762.490 0 to 15249.7
GPM (0.33 ft/s) GPM (1.64 ft/s) GPM (33 ft/s)
0.1 0 to 0.0078 0 to 0.0389 0 to 0.7780 16 0 to 199.182 0 to 995.906 0 to 19918.1
0.2 0 to 0.0312 0 to 0.1557 0 to 3.1122 20 0 to 311.3 0 to 1556 0 to 31122
0.4 0 to 0.1245 0 to 0.6225 0 to 12.4488
0.5 0 to 0.2801 0 to 1.4005 0 to 28.0098
1 0 to 0.7781 0 to 3.8903 0 to 77.8050
1.25 0 to 1.2748 0 to 6.3738 0 to 127.475
1.5 0 to 1.9919 0 to 9.9591 0 to 199.181
2 0 to 3.1123 0 to 15.5611 0 to 311.220
2.5 0 to 5.2597 0 to 26.2982 0 to 525.962
3 0 to 7.9673 0 to 39.8363 0 to 796.724
4 0 to 12.4489 0 to 62.2441 0 to 1244.88
5 0 to 19.4513 0 to 97.2564 0 to 1945.12
6 0 to 28.0099 0 to 140.049 0 to 2800.98
8 0 to 49.7953 0 to 248.977 0 to 4979.52
10 0 to 77.8051 0 to 389.026 0 to 7780.5
12 0 to 112.040 0 to 560.197 0 to 11203.9
14 0 to 152.498 0 to 762.490 0 to 15249.7
16 0 to 199.182 0 to 995.906 0 to 19918.1

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
112
(3) Combined with AXFA11 Remote Transmitter 6. Totalizer Display Pulse Weight (Totalizer 1)
SI Units (Size: mm, Flow rate: m3/h) Specify the volume flow per pulse, after specifying
Size 0 to Min. Span Flow Rate 0 to Max. Span Flow Rate the span flow rate. This totalizer display pulse
(mm) m3/h (0.1 m/s) m3/h (10 m/s) weight is set to the Totalizer 1. For unit, specify
2.5 0 to 0.0018 0 to 0.1767
"unit/p" which means "(the same unit as the flow
5 0 to 0.0071 0 to 0.7068
10 0 to 0.0283 0 to 2.8274
rate span)/p".
15 0 to 0.0637 0 to 6.361 (Example: When "m3" is selected for "Span Flow
25 0 to 0.1768 0 to 17.671 Rate", "unit/p" means "m3/p".)
32 0 to 0.2896 0 to 28.952
40 0 to 0.4524 0 to 45.23
The specifiable numerical digit and range is the
50 0 to 0.7069 0 to 70.68 same as that for "4. Range and Unit of Flowrate
65 0 to 1.1946 0 to 119.45 Span.
80 0 to 1.8096 0 to 180.95 Unless specified, it is set as the following when
100 0 to 2.8275 0 to 282.74
shipped.
125 0 to 4.418 0 to 441.7
150 0 to 6.362 0 to 636.1 • Integral Flowmeter, or combined with AXG4A or
200 0 to 11.310 0 to 1130.9 AXG1A Remote Transmitter 1 [span unit/p]
250 0 to 17.672 0 to 1767.1 • Combined with AXFA11 Remote Transmitter 0
300 0 to 25.447 0 to 2544.6 pulse/s
350 0 to 34.64 0 to 3463
400 0 to 45.24 0 to 4523 7. Mass Unit (optional code MU)
500 0 to 70.69 0 to 7068
The flow rate calculation is performed in mass unit.
English Units (Size: in., Flow rate: GPM) In addition to fluid density, specify span flow rate,
Size 0 to Min. Span Flow Rate 0 to Max. Span Flow Rate output pulse weight, and totalizer display pulse
(in.) GPM (0.33 ft/s) GPM (33 ft/s) weight in mass unit.
0.1 0 to 0.0078 0 to 0.7780 The specifiable numerical digit and range is the
0.2 0 to 0.0312 0 to 3.112
0.4 0 to 0.1245 0 to 12.44
same as that for "4. Range and Unit of FLowrate
0.5 0 to 0.1946 0 to 19.45 Span.
1 0 to 0.7781 0 to 77.80 (1) Density
1.25 0 to 1.216 0 to 121.5
1.5 0 to 1.751 0 to 175.0
Numerical Value:
2 0 to 3.113 0 to 311.2 Specify within six digits (up to three digits
2.5 0 to 4.863 0 to 486.2 below the decimal point) in the range of 500
3 0 to 7.003 0 to 700.2 to 2000 kg/m3 (4.2 to 16.7 lb/gal, 31.2 to
4 0 to 12.45 0 to 1244 124.8 lb/cf). If BRAIN communication type is
5 0 to 19.46 0 to 1945
selected, specify so that the numerical value
6 0 to 28.01 0 to 2800
8 0 to 49.80 0 to 4979
excluding the decimal point is within 32000.
10 0 to 77.81 0 to 7780 Unit:
12 0 to 112.1 0 to 11203
kg/m3, lb/gal, lb/cf
14 0 to 152.5 0 to 15249
16 0 to 199.2 0 to 19918 The density of water is about 1000 kg/m3.
20 0 to 311.3 0 to 31122 Then specify "1000 kg/m3" in this case.
However, as the density varies with
temperature, specify the density at the time
5. Output Pulse Weight (Pulse Status Output 1)
of flow measurement.
Specify the volume flow per pulse, after specifying
(2) Flowrate Span
the span flow rate. This output pulse weight is set to
the Pulse Status Output 1. For unit, specify "unit/p" Numerical Value:
which means "(the same unit as the flow rate span)/ When setting the mass span flow rate,
p". calculate the volume span flow rate from
(Example: When "m3" is selected for "Span Flow the "density" and it must be within the
Rate", "unit/p" means "m3/p".) measurable flow rate range. The settable
numerical range for the mass span flow rate
The specifiable numerical digit and range is the
is the same as that for the volume span flow
same as that for "4. Range and Unit of Flowrate
rate.
Span.
Unit:
Unless specified, it is set as the following when
shipped. Mass Unit: t, kg, g, klb, lb
• Integral Flowmeter, or combined with AXG4A or Time Unit: /d, /h, /min, /s
AXG1A Remote Transmitter 0 [span unit/p] (3) Output Pulse Weight, Totalizer Display Pulse
• Combined with AXFA11 Remote Transmitter 0 Weight
pulse/s For unit, specify "unit/p" which means "(the
Not applicable for EtherNet/IP communication type. same unit as the flow rate span)/p".

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
113
8. Specified Span Five-point Calibration (optional code Direction of Cable Entry
SC) Standard +90 degree +180 degree -90 degree
(0 degree) rotation rotation rotation
A flow test at the five points around 0, 25, 50, 75,
Display
100% of the customer specified span is performed. Cable Entry Cable Entry Display

In the test certificate (QIC), the result for the Integral


Flowmeter
customer specified span is recorded instead of
that for the standard flow rate of 2 m/s (6.56 ft/s).
Corresponding flow velocity of the selectable span Front side Cable Entry Back side Cable Entry
lies between 0.5 to 10 m/s (1.64 to 33 ft/s) or 0.8 to Remote
10 m/s (2.62 to 33 ft/s). The latter is applied when Sensor
the size is 32, 65, or 125 mm (1.25, 2.5, or 5 in.). It
is also limited by the capacity of our flow test facility.
Specify it within the following range. The specifiable 10. Direction of Display
numerical digit and range is the same as that for "4. When the specification "With Display" is selected
Range and Unit of FLowrate Span. for the integral flowmeter or the remote transmitter,
specify direction of the display. For the integral
Selectable Range of Flow Rate Span
flowmeter, specify according to the horizontal or
SI Units (Size: mm, Flow rate: m3/h) vertical direction of the installation piping. For
Size Min. Span Flow Rate Max. Span Flow Rate the remote transmitter, specify according to the
(mm) m3/h (m/s) m3/h (m/s) positional relation of mounting bracket or mounting
2.5 0.009 (0.5) 0.05 (2.83)
pipe.
5 0.036 (0.5) 0.20 (2.83)
10 0.15 (0.5) 0.96 (3.40)
15 0.32 (0.5) 2.80 (4.40) Direction of Display
Without Display
25 0.89 (0.5) 11.0 (6.22) Horizontal Vertical
32 2.32 (0.8) 28.9 (9.98)
40 2.27 (0.5) 28.0 (6.19) Integral
50 3.54 (0.5) 56.0 (7.92) Flowmeter
65 9.56 (0.8) 80.0 (6.70)
80 9.05 (0.5) 126 (6.96)
100 14.2 (0.5) 190 (6.72)
125 35.4 (0.8) 300 (6.79) Remote
150 31.9 (0.5) 380 (5.97) Transmitter Mounting pipe Mounting
Mounting bracket
200 56.6 (0.5) 670 (5.92) bracket Mounting
Mounting pipe
bracket
250 88.4 (0.5) 1000 (5.66) Mounting pipe

300 128 (0.5) 1200 (4.72)


350 174 (0.5) 1200 (3.46) 11. Fluid Name
400 227 (0.5) 1350 (2.98)
500 354 (0.5) 7068 (10.0) 12. Modbus Protocol parameters
English Units (Size: in., Flow rate: GPM) Specify the following parameters for Modbus
Size Min. Span Flow Rate Max. Span Flow Rate communication.
(in.) GPM (ft/s) GPM (ft/s)
0.1 0.039 (1.64) 0.2201 (9.28) Parameter to be
0.2 0.1557 (1.64) 0.8805 (9.28) Selectable value
specified
0.4 0.6225 (1.64) 4.2267 (11.1)
0.5 1.4005 (1.64) 12.328 (14.4) Baud rate [bps] 1200, 2400, 4800, 9600, 19200*,
1 3.8903 (1.64) 48.4315 (20.4) 38400, 57600, 115200
1.25 10.1981 (2.62) 127.242 (32.7)
Stop bit 1 bit*, 2 bits
1.5 9.9591 (1.64) 123.280 (20.3)
2 15.5611 (1.64) 246.560 (25.9) Parity bit Odd, Even*, None
2.5 42.0770 (2.62) 352.229 (21.9)
Slave address 1* to 247 (decimal value.)
3 39.8363 (1.64) 554.761 (22.8)
4 62.2441 (1.64) 836.544 (22.0) *: Factory default setting. If the parameter is not specified
5 156.052 (2.62) 1320.86 (22.2) at ordering, these settings are applied to the parameter
6 140.050 (1.64) 1673.08 (19.5) for Modbus communication.
8 248.977 (1.64) 2949.92 (19.4)
10 389.026 (1.64) 4402.86 (18.5)
12 560.197 (1.64) 5283.44 (15.4)
14 762.490 (1.64) 5283.44 (11.3)
16 995.906 (1.64) 5943.87 (9.78)
20 1556.11 (1.64) 31119.4 (32.8)

9. Direction of Cable Entry (optional code RH)


Rotate the transmitter of integral flowmeter or the
terminal box of remote sensor and change the
direction of the cable entry. See the table below
and specify either +90, +180, or -90 degree. When
the direction of cable entry is not changed, optional
code RH is not necessary.

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00
114
13. EtherNet/IP communication parameters n SECURITY
The following parameters can be set at factory. For EtherNet/IP communication type, The device can be
supported as a range of warranty only when the device
is installed and used in Control and Field network.
Parameter to be
Value Operator must have the responsible for IT security of
specified
equipment that is connected with the device, and this
DHCP enable Disable*, Enable
device must not connect with IT network.
IP address 192.168.1.210*
In addition, parameter configuration can be locked by
Subnet mask 255.255.255.0* hardware switch.
Default gateway (empty)*
*: Factory default setting. If the parameter is not specified at n TRADEMARKS
ordering, these settings are applied to the parameter for HART is a registered trademark of FieldComm Group.
EtherNet/IP communication. Viton is a registered trademark of DuPont.
14. ISO/IEC 17025 calibration (optional code L10, L11, Tri-Clamp is a registered trademark of Alfa Laval.
L12)
Modbus is a registered trademark of AEDG Schneider.
Please specify the customer name, address, and
flow rate span (only for L11, L12). Please refer to "FOUNDATION" in "FOUNDATION Fieldbus" is a registered
trademark of FieldComm Group.
the "ISO/IEC 17025 calibration-related confirmation
list" when ordering. PROFIBUS is a registered trademark of Profibus
Nutzerorganisation e.v., Karlsruhe, Germany.
In the test certificate (QIC), the result for the
customer specified span is recorded instead of "EtherNet/IP", "CIP" and "ODVA" are trademarks or
that for the standard flow rate of 2 m/s (6.56 ft/s), registered trademarks of ODVA Inc.
when the optional codes L11 or L12 is selected. 3-A is a registered trademark of 3-A Sanitary Standards Inc.
Please refer to the "ISO/IEC 17025 Calibration Det Norske Veritas is a registered trademark of Det
Confirmation" when ordering. Norske Veritas Group.
ADMAG, AXG, AXW, BRAIN TERMINAL, and
n RELATED INSTRUMENTS FieldMate are registered trademarks of Yokogawa
Electric Corporation.
Product Document Number All other company and product names mentioned in this
AM012 Calibrator for Magnetic Flowmeter GS 1E6K2-E document are trade names, trademarks or registered
BT200 BRAIN TERMINAL GS 01C00A11-00EN trademarks of their respective companies.
AXFA11G Magnetic Flowmeter Remote In this document, trademarks or registered trademarks
GS 01E20C01-01E
Converter are not marked with ™ or ®.
AXG1A Magnetic Flowmeter Remote Transmitter GS 01E22C01-01EN Note: The terms “transmitter” and “sensor” in this document are used
Magnetic Flowmeter CA Series GS 01E40A01-01EN in the same manner as “converter” and “flowtube” respectively
ADMAG CA Capacitance Magnetic Flowmeter GS 01E08B01-00E which are used for our previous magnetic flowmeter models.
FieldMate Versatile Device Management Wizard GS 01R01A01-01E
ADMAG TI Series
<Information on EU WEEE Directive>
AXW Magnetic Flowmeter GS 01E24A01-01EN EU WEEE (Waste Electrical and Electronic Equipment)
[Size: 25 to 400 mm (1 to 16 in.)]
Directive is only valid in the EU.
ADMAG TI Series
AXW Magnetic Flowmeter GS 01E25D11-01EN This instrument is intended to be sold and used only as
[Size: 500 to 1800 mm (20 to 72 in.)] a part of equipment which is excluded from WEEE
ADMAG TI Series FOUNDATION Fieldbus GS 01E21F02-01EN Directive, such as large-scale stationary industrial
ADMAG TI Series EtherNet/IP GS 01E21F02-02EN tools, a large-scale fixed installation and so on, and,
ADMAG TI Series PROFIBUS PA GS 01E21F02-03EN therefore, subjected to the exclusion from the scope
FSA130 ADMAG TI Verification Tool GS 01E21A04-01EN of the WEEE Directive. The instrument should be
disposed of in accordance with local and national
legislation/regulations.
n REFERENCE STANDARD
Design and Test on Magnetic Flowmeters:
JIS B 7554(1997), ISO 20456(2017),
NAMUR NE70(2006), ASME MFC-16-2014

All Rights Reserved. Copyright © 2017, Yokogawa Electric Corporation GS 01E22A01-01EN May 30, 2025-00