Instrumental Analysis: Fluorimetry, Turbidimetry, and Nephelometry Quiz
1. Question: In fluorimetry, the relationship between the intensity of fluorescence
and the concentration of the analyte is described by which of the following
laws?
o A. Beer-Lambert Law
o B. Stern-Volmer Equation
o C. Beer's Law
o D. Luminescence Law
o Correct Answer: D. Luminescence Law
o Rationale: The intensity of fluorescence is directly proportional to the
concentration of the fluorophore at low concentrations, a fundamental
principle of fluorimetry.
2. Question: What is the primary function of the excitation monochromator in a
fluorimeter?
o A. To measure the intensity of the emitted light.
o B. To select the specific wavelength of light used to excite the sample.
o C. To filter out scattered light.
o D. To split the light into multiple beams.
o Correct Answer: B. To select the specific wavelength of light used to
excite the sample.
o Rationale: The excitation monochromator is placed between the light
source and the sample to isolate a specific wavelength of light that will be
absorbed by the analyte, causing it to fluoresce.
3. Question: Which of the following is a common application of fluorimetry?
o A. Measuring the concentration of a colored solution.
o B. Determining the molecular weight of a protein.
o C. Quantifying DNA and RNA concentrations in a sample.
o D. Analyzing the elemental composition of a sample.
o Correct Answer: C. Quantifying DNA and RNA concentrations in a
sample.
o Rationale: Fluorescent dyes that bind to nucleic acids allow for highly
sensitive and specific quantification of DNA and RNA, a common
application in molecular biology.
4. Question: In turbidimetry, what is being measured by the detector?
o A. The intensity of scattered light at a 90∘ angle.
o B. The decrease in the intensity of light transmitted through the sample.
o C. The color of the solution.
o D. The change in wavelength of the incident light.
o Correct Answer: B. The decrease in the intensity of light transmitted
through the sample.
o Rationale: Turbidimetry measures the attenuation of the incident light
beam as it passes through the sample due to scattering and absorption by
suspended particles.
5. Question: Which of the following describes the key difference between
turbidimetry and nephelometry?
o A. Turbidimetry is more sensitive than nephelometry.
o B. Turbidimetry measures transmitted light, while nephelometry
measures scattered light.
o C. Turbidimetry is used for gases, while nephelometry is used for liquids.
o D. Turbidimetry is based on absorption, while nephelometry is based on
scattering.
o Correct Answer: B. Turbidimetry measures transmitted light, while
nephelometry measures scattered light.
o Rationale: This is the fundamental difference. Turbidimetry measures the
reduction in light that passes through the sample, while nephelometry
measures the light that is deflected by the particles.
6. Question: Why is the detector typically placed at a 90∘ angle to the incident
beam in nephelometry?
o A. To measure the transmitted light more accurately.
o B. To maximize the detection of scattered light while minimizing
interference from the incident beam.
o C. Because light is scattered only at a 90∘ angle.
o D. To increase the speed of the measurement.
o Correct Answer: B. To maximize the detection of scattered light while
minimizing interference from the incident beam.
o Rationale: Positioning the detector at a 90∘ angle to the light source
allows it to primarily detect the light scattered by the particles, as the
direct, high-intensity incident beam is blocked.
7. Question: Which of the following is an application of nephelometry?
o A. Analyzing the concentration of a dissolved salt in water.
o B. Monitoring bacterial growth in a culture medium.
o C. Identifying a specific functional group in an organic compound.
o D. Determining the melting point of a solid.
o Correct Answer: B. Monitoring bacterial growth in a culture medium.
o Rationale: As bacteria grow, they form a suspension that increases the
turbidity of the medium. Nephelometry can be used to monitor this
increase in scattered light, which correlates with cell concentration.
8. Question: What is the phenomenon called when an excited molecule loses its
energy non-radiatively through collisions with other molecules?
o A. Phosphorescence
o B. Fluorescence
o C. Quenching
o D. Intersystem crossing
o Correct Answer: C. Quenching
o Rationale: Quenching is a general term for any process that decreases the
fluorescence intensity of a sample, often involving a non-radiative energy
transfer due to collisions or other interactions.
9. Question: Which of the following instruments can be used to measure
turbidity?
o A. Refractometer
o B. Spectrophotometer
o C. pH meter
o D. Calorimeter
o Correct Answer: B. Spectrophotometer
o Rationale: A standard spectrophotometer can be used to measure
turbidity because it measures the absorbance, which is an indirect
measure of the light transmitted through the sample.
10.Question: In nephelometry, what is the relationship between the intensity of
scattered light (Is) and the concentration of the suspended particles (C)?
o A. Is is inversely proportional to C.
o B. Is is proportional to the square of C.
o C. Is is directly proportional to C.
o D. Is is independent of C.
o Correct Answer: C. Is is directly proportional to C.
o Rationale: In a dilute suspension, the scattered light intensity increases
linearly with the concentration of the suspended particles.
11.Question: The measurement of the decrease in light intensity as it passes
through a suspension is the principle of:
o A. Nephelometry
o B. Fluorimetry
o C. Turbidimetry
o D. Spectrophotometry
o Correct Answer: C. Turbidimetry
o Rationale: Turbidimetry is based on the measurement of the light
transmitted through a turbid sample, which is inversely related to the
concentration of suspended particles.
12.Question: What physical phenomenon is the basis for both turbidimetry and
nephelometry?
o A. The Photoelectric effect.
o B. The Tyndall effect.
o C. The Doppler effect.
o D. Beer's Law.
o Correct Answer: B. The Tyndall effect.
o Rationale: The Tyndall effect is the scattering of light by suspended
particles in a colloid or a suspension, which is the fundamental principle
for both techniques.
13.Question: A turbidimeter is best suited for analyzing samples with:
o A. Very low concentrations of suspended particles.
o B. High concentrations of suspended particles.
o C. High concentrations of a dissolved colored substance.
o D. Samples that do not contain any suspended particles.
o Correct Answer: B. High concentrations of suspended particles.
o Rationale: Turbidimetry works best with higher concentrations where the
decrease in transmitted light is significant enough to be accurately
measured.
14.Question: In nephelometry, the detector is typically positioned at a 90∘ angle to
the incident light beam. This is done to:
o A. Measure the scattered light and exclude the transmitted light.
o B. Increase the intensity of the incident light.
o C. Detect the light that is absorbed by the particles.
o D. Ensure the measurement follows the Beer-Lambert Law.
o Correct Answer: A. Measure the scattered light and exclude the
transmitted light.
o Rationale: Placing the detector at a right angle allows it to measure only
the scattered light, while the transmitted light continues in a straight path
and is not detected.
15.Question: Which of the following is a key advantage of nephelometry over
turbidimetry?
o A. It can be used for highly concentrated suspensions.
o B. It is less expensive to set up.
o C. It provides a more accurate measurement for very low concentrations
of particles.
o D. It is not affected by the color of the solution.
o Correct Answer: C. It provides a more accurate measurement for very
low concentrations of particles.
o Rationale: Because it measures scattered light directly, nephelometry is
more sensitive to small numbers of particles, making it ideal for dilute
suspensions.
16.Question: What kind of sample is ideal for analysis by nephelometry or
turbidimetry?
o A. A clear, transparent liquid.
o B. A solid with a crystalline structure.
o C. A solution of a single, pure chemical compound.
o D. A suspension of fine, insoluble particles in a liquid.
o Correct Answer: D. A suspension of fine, insoluble particles in a liquid.
o Rationale: Both turbidimetry and nephelometry are based on the
scattering of light by suspended particles.
17.Question: In turbidimetry, the relationship between transmitted light intensity
and concentration is not always linear. Why is this?
o A. The light source is not powerful enough.
o B. Particles at higher concentrations may interfere with each other,
leading to multiple scattering.
o C. The detector is not sensitive enough.
o D. The particles are too large.
o Correct Answer: B. Particles at higher concentrations may interfere with
each other, leading to multiple scattering.
o Rationale: At high concentrations, particles can interact with each other
and scatter light multiple times before it reaches the detector, causing a
deviation from a linear relationship.
18.Question: Which of the following is a common application of both turbidimetry
and nephelometry?
o A. Determining the freezing point of a substance.
o B. Assessing the concentration of a clear, colored dye.
o C. Monitoring the quality of water in municipal treatment plants.
o D. Measuring the pH of a solution.
o Correct Answer: C. Monitoring the quality of water in municipal
treatment plants.
o Rationale: Water clarity is a critical parameter in water quality analysis,
and both techniques are used to measure the turbidity caused by
suspended solids.
19.Question: What kind of a detector is most suitable for nephelometry, given the
low intensity of scattered light?
o A. A standard photocell.
o B. A photomultiplier tube (PMT).
o C. A gas chromatograph.
o D. A tungsten lamp.
o Correct Answer: B. A photomultiplier tube (PMT).
o Rationale: A PMT is a highly sensitive detector that can amplify the
weak scattered light signal, making it ideal for nephelometry.
20.Question: What is the relationship between the intensity of scattered light (Is)
and the concentration (C) of particles in a dilute suspension, according to
nephelometry?
o A. Is is inversely proportional to C.
o B. Is is proportional to the square of C.
o C. Is is directly proportional to C.
o D. Is is independent of C.
o Correct Answer: C. Is is directly proportional to C.
o Rationale: In a dilute suspension, the scattered light intensity increases
linearly with the concentration of the suspended particles.
21.Question: Which of the following is an example of a common application of
turbidimetry?
o A. Measuring the concentration of a protein in a clinical sample by
forming a suspension with an antigen-antibody reaction.
o B. Monitoring the growth of bacteria in a culture medium.
o C. Detecting trace amounts of heavy metals in water.
o D. Assessing the clarity of a transparent liquid like alcohol.
o Correct Answer: B. Monitoring the growth of bacteria in a culture
medium.
o Rationale: As bacteria grow, the turbidity increases, which can be
measured by monitoring the decrease in transmitted light, making it a
common turbidimetric application.
22.Question: What is the main function of the slit in a monochromator?
o A. To focus the light onto the sample.
o B. To control the intensity of the light source.
o C. To narrow the light beam and select a specific wavelength band.
o D. To absorb unwanted light.
o Correct Answer: C. To narrow the light beam and select a specific
wavelength band.
o Rationale: The slit controls the spectral bandwidth of the light that
passes through the monochromator, affecting the resolution of the
measurement.
23.Question: The Quantum Yield of a fluorophore is a measure of the efficiency
of the fluorescence process. It is defined as the ratio of:
o A. The number of photons absorbed to the number of photons emitted.
o B. The intensity of the excitation light to the intensity of the emitted light.
o C. The number of photons emitted to the number of photons absorbed.
o D. The total energy of the emitted light to the total energy of the absorbed
light.
o Correct Answer: C. The number of photons emitted to the number of
photons absorbed.
o Rationale: Quantum yield is a quantitative measure of how efficiently a
substance fluoresces, calculated as the ratio of photons emitted to photons
absorbed.
24.Question: Which of the following describes the electronic transition that leads
to fluorescence?
o A. A transition from a singlet excited state (S1) to a ground singlet state
(S0).
o B. A transition from a triplet excited state (T1) to a ground singlet state
(S0).
o C. A transition from a ground state (S0) to a singlet excited state (S1).
o D. A transition from a ground state (S0) to a triplet excited state (T1).
o Correct Answer: A. A transition from a singlet excited state (S1) to a
ground singlet state (S0).
o Rationale: Fluorescence is defined as the radiative transition from the
lowest vibrational level of the first excited singlet state to a vibrational
level of the ground singlet state.
25.Question: In a fluorimeter, why are quartz sample cells used instead of glass
cells?
o A. Quartz is less expensive than glass.
o B. Quartz is more resistant to heat and chemicals.
o C. Quartz does not absorb UV light, which is often used for excitation.
o D. Quartz has a higher refractive index than glass.
o Correct Answer: C. Quartz does not absorb UV light, which is often
used for excitation.
o Rationale: Glass absorbs UV light, which would interfere with the
excitation process. Quartz is transparent to UV light, allowing it to pass
through to the sample.
26.Question: The concentration of suspended particles in a solution is directly
proportional to the turbidity of the solution. This holds true as long as:
o A. The particles are colored.
o B. The particles are all the same size.
o C. The suspension is dilute and free from multiple scattering effects.
o D. The solution is completely transparent.
o Correct Answer: C. The suspension is dilute and free from multiple
scattering effects.
o Rationale: At high concentrations, multiple scattering events lead to a
non-linear relationship. Linearity holds best in dilute suspensions.
27.Question: What is the main application of turbidimetry in a brewery or a
beverage industry?
o A. Measuring the alcohol content.
o B. Analyzing the sugar content of the liquid.
o C. Monitoring the clarity and stability of the product.
o D. Determining the pH of the beverage.
o Correct Answer: C. Monitoring the clarity and stability of the product.
o Rationale: Turbidimetry is used to check for cloudiness, haze, or
suspended particles that affect the visual quality of beverages like beer or
wine.
28.Question: The detector in a nephelometer measures the intensity of scattered
light, which is directly related to the:
o A. Transmitted light.
o B. Absorbed light.
o C. Concentration of the suspended particles.
o D. Wavelength of the incident light.
o Correct Answer: C. Concentration of the suspended particles.
o Rationale: The amount of light scattered is proportional to the number of
particles in a dilute solution, which allows for the quantification of their
concentration.
29.Question: Which of the following is NOT a component of a typical
fluorimeter?
o A. An oven or furnace.
o B. A light source.
o C. A detector.
o D. Monochromators or filters.
o Correct Answer: A. An oven or furnace.
o Rationale: An oven or furnace is used in techniques like atomic
absorption or emission spectroscopy, not in a typical fluorimeter.
30.Question: Why is a high-pressure xenon arc lamp often used as a light source in
a spectrofluorimeter?
o A. It emits light at a single, precise wavelength.
o B. It provides a continuous and intense spectrum across the UV-Vis
range.
o C. It is very inexpensive to operate.
o D. It is only capable of producing visible light.
o Correct Answer: B. It provides a continuous and intense spectrum
across the UV-Vis range.
o Rationale: The broad, continuous spectrum of a xenon arc lamp allows
for the selection of any excitation wavelength, making it ideal for
spectrofluorimeters.
31.Question: Which of the following describes the process of internal conversion
in a fluorophore?
o A. A radiative transition from an excited state to the ground state.
o B. A non-radiative transition between two states of the same spin
multiplicity.
o C. A non-radiative transition between a singlet and a triplet state.
o D. A transition from a ground state to an excited state.
o Correct Answer: B. A non-radiative transition between two states of the
same spin multiplicity.
o Rationale: Internal conversion is a non-radiative process where a
molecule transitions from a higher vibrational energy level to a lower one
within the same electronic state (e.g., S2 to S1).
32.Question: What is the main advantage of a spectrofluorimeter over a filter
fluorimeter?
o A. It is more portable.
o B. It allows for the selection of a wider range of excitation and emission
wavelengths.
o C. It is more sensitive.
o D. It has a lower initial cost.
o Correct Answer: B. It allows for the selection of a wider range of
excitation and emission wavelengths.
o Rationale: The use of monochromators in a spectrofluorimeter provides
greater flexibility in selecting wavelengths compared to the fixed
wavelengths of filters in a filter fluorimeter.
33.Question: In turbidimetry, the intensity of the light that passes through the
sample is measured by a detector placed:
o A. At a 45∘ angle to the light source.
o B. In line with the light source.
o C. At a 90∘ angle to the light source.
o D. Opposite to the light source, with a mirror.
o Correct Answer: B. In line with the light source.
o Rationale: Turbidimetry measures transmitted light, so the detector must
be placed in a straight line from the light source, through the sample, and
to the detector.
34.Question: A sample is placed in a nephelometer, and the measured scattered
light intensity is 100 units. If the concentration of the suspended particles is
doubled, what would be the expected scattered light intensity (assuming the
solution is dilute)?
o A. 50 units
o B. 100 units
o C. 200 units
o D. 400 units
o Correct Answer: C. 200 units
o Rationale: For dilute suspensions, the intensity of scattered light is
directly proportional to the concentration. Doubling the concentration
would double the signal.
35.Question: What is the function of the emission filter in a filter fluorimeter?
o A. To select the wavelength of light used to excite the sample.
o B. To block the excitation light from reaching the detector.
o C. To measure the intensity of the fluorescence.
o D. To focus the emitted light onto the detector.
o Correct Answer: B. To block the excitation light from reaching the
detector.
o Rationale: The emission filter is positioned after the sample to allow the
longer wavelength fluorescence to pass through while blocking the
shorter wavelength excitation light that may have been scattered by the
sample.
36.Question: Which of the following is a limitation of both turbidimetry and
nephelometry?
o A. They are not sensitive to particle size.
o B. They are not able to measure very low concentrations.
o C. The presence of colored substances in the sample can interfere with
the measurement.
o D. They require a large sample volume.
o Correct Answer: C. The presence of colored substances in the sample
can interfere with the measurement.
o Rationale: If the sample or suspended particles are colored, they will
absorb light, affecting both the transmitted and scattered light signals,
which can lead to inaccuracies.
37.Question: In nephelometry, the intensity of scattered light is measured at a 90∘
angle. What is the light measured at 180∘?
o A. Reflected light.
o B. Absorbed light.
o C. Transmitted light.
o D. Phosphorescence.
o Correct Answer: C. Transmitted light.
o Rationale: Light that passes straight through the sample in line with the
source is the transmitted light.
38.Question: How does an increase in temperature generally affect fluorescence
intensity?
o A. It increases it.
o B. It decreases it.
o C. It has no effect.
o D. The effect is unpredictable.
o Correct Answer: B. It decreases it.
o Rationale: An increase in temperature leads to more molecular
collisions, which increases the rate of non-radiative relaxation pathways
(quenching), thereby decreasing the fluorescence intensity.
39.Question: Which of the following is a characteristic of phosphorescence that
distinguishes it from fluorescence?
o A. It occurs at a shorter wavelength than fluorescence.
o B. It involves a transition from a singlet to a triplet state.
o C. It has a much longer decay time (delay) after excitation.
o D. It is a non-radiative process.
o Correct Answer: C. It has a much longer decay time (delay) after
excitation.
o Rationale: Phosphorescence involves a forbidden intersystem crossing
from a singlet to a triplet state, leading to a much slower return to the
ground state and a delayed emission of light.
40.Question: What is the primary purpose of a reference cell in a fluorimeter?
o A. To hold the blank solution for calibration.
o B. To measure the intensity of the light source.
o C. To correct for fluctuations in the light source intensity.
o D. To cool the sample and prevent quenching.
o Correct Answer: C. To correct for fluctuations in the light source
intensity.
o Rationale: A reference cell and a reference detector are often used in
double-beam fluorimeters to monitor the light source and compensate for
any variations in its intensity, improving accuracy.
41.Question: The term turbidity is a measure of the:
o A. Color of a solution.
o B. Concentration of a dissolved solute.
o C. Cloudiness or haziness of a fluid caused by suspended particles.
o D. Acidity of a liquid.
o Correct Answer: C. Cloudiness or haziness of a fluid caused by
suspended particles.
o Rationale: Turbidity is a measure of the light-scattering property of a
suspension, which is directly related to its cloudiness.
42.Question: Which of the following is a key application of turbidimetry in
medicine?
o A. Measuring the concentration of blood glucose.
o B. Determining the concentration of white blood cells in a sample.
o C. Measuring the amount of protein in urine.
o D. Quantifying the concentration of bacteria in a lab culture.
o Correct Answer: D. Quantifying the concentration of bacteria in a lab
culture.
o Rationale: As bacteria grow, they make the culture medium more turbid,
a change that can be measured with a turbidimeter to monitor the
population size.
43.Question: The intensity of scattered light in nephelometry is dependent on:
o A. The color of the particles.
o B. The size, shape, and number of the particles.
o C. The concentration of the solvent.
o D. The temperature of the solution.
o Correct Answer: B. The size, shape, and number of the particles.
o Rationale: The amount of light scattered is a complex function of the
physical properties of the suspended particles, including their size, shape,
and concentration.
44.Question: What is the main advantage of using a PMT detector in fluorimetry?
o A. Its low cost.
o B. Its ability to detect a wide range of wavelengths.
o C. Its high sensitivity to low light levels.
o D. Its ability to operate at high temperatures.
o Correct Answer: C. Its high sensitivity to low light levels.
o Rationale: Fluorescence is a weak signal, and PMTs are capable of
amplifying this signal, making them ideal for the low light intensities
common in fluorimetry.
45.Question: Which of the following is a non-radiative pathway for an excited
molecule to lose energy?
o A. Fluorescence
o B. Phosphorescence
o C. Internal conversion
o D. Luminescence
o Correct Answer: C. Internal conversion
o Rationale: Internal conversion is a non-radiative process where the
molecule loses energy through vibrational relaxation, without emitting a
photon.
46.Question: What is the standard used for calibrating a nephelometer or
turbidimeter?
o A. A solution of potassium permanganate.
o B. A solution of formazin.
o C. A solution of copper sulfate.
o D. A solution of sodium chloride.
o Correct Answer: B. A solution of formazin.
o Rationale: Formazin is a polymer suspension that is a primary standard
for calibrating turbidimeters and nephelometers.
47.Question: The term quantum efficiency in fluorimetry is synonymous with:
o A. Quantum yield.
o B. Molar absorptivity.
o C. Luminescence.
o D. Quenching.
o Correct Answer: A. Quantum yield.
o Rationale: Quantum efficiency and quantum yield are synonymous terms
that describe the ratio of emitted to absorbed photons.
48.Question: Which of the following is a significant source of error in
fluorimetry?
o A. Stray light from the light source reaching the detector.
o B. High concentration of the analyte.
o C. Temperature fluctuations in the sample.
o D. All of the above.
o Correct Answer: D. All of the above.
o Rationale: All of these factors—stray light, high concentrations (leading
to inner filter effect and self-quenching), and temperature changes
(affecting non-radiative decay)—can significantly affect the accuracy of
fluorescence measurements.
49.Question: The inner filter effect is a type of quenching that occurs at high
concentrations. It is caused by:
o A. The absorption of emitted light by other fluorophores.
o B. The absorption of both excitation and emitted light by the analyte
itself.
o C. Collisional deactivation between fluorophores.
o D. The interaction of the solvent with the fluorophore.
o Correct Answer: B. The absorption of both excitation and emitted light
by the analyte itself.
o Rationale: At high concentrations, the analyte itself can absorb a
significant portion of the excitation light (primary inner filter effect) and
the emitted light (secondary inner filter effect) before they reach the
detector.
50.Question: Which of the following is an advantage of fluorimetry over
absorption spectroscopy (spectrophotometry)?
o A. Higher selectivity.
o B. Higher sensitivity.
o C. A wider linear range for concentration.
o D. Both A and B.
o Correct Answer: D. Both A and B.
o Rationale: Fluorimetry is generally more selective because it requires
both a specific absorption and a specific emission profile. It is also more
sensitive as it measures an emitted signal against a dark background,
whereas absorption measures a small difference between two large
signals.
51.Question: In a turbidimetric measurement, the relationship between the
measured signal (absorbance) and the concentration is linear according to:
o A. The Luminescence Law.
o B. The Stern-Volmer Equation.
o C. Beer's Law.
o D. Rayleigh's Law.
o Correct Answer: C. Beer's Law.
o Rationale: Although the measurement is due to scattering, the instrument
(often a spectrophotometer) measures the light attenuation in a way that
can be related to concentration via Beer's Law, but with significant
deviations at high concentrations.
52.Question: Which of the following would produce a turbid solution suitable for
turbidimetry?
o A. A solution of table salt in water.
o B. A solution of sugar in water.
o C. A suspension of clay in water.
o D. A solution of food coloring in water.
o Correct Answer: C. A suspension of clay in water.
o Rationale: Turbidimetry requires a suspension of insoluble particles.
Salt, sugar, and food coloring all dissolve completely to form clear
solutions.
53.Question: In nephelometry, as the particle size increases, the scattering
becomes more forward-directed. This is described by:
o A. Rayleigh scattering.
o B. Mie scattering.
o C. The Tyndall effect.
o D. The Lambert-Beer Law.
o Correct Answer: B. Mie scattering.
o Rationale: Mie scattering theory describes the scattering of light by
particles that are larger than the wavelength of the incident light, resulting
in a more forward-directed scattering pattern. Rayleigh scattering applies
to much smaller particles.
54.Question: What is the primary purpose of a filter in a filter fluorimeter?
o A. To select a narrow band of wavelengths.
o B. To completely block all light.
o C. To amplify the light signal.
o D. To cool the sample.
o Correct Answer: A. To select a narrow band of wavelengths.
o Rationale: Filters are used to isolate specific wavelengths for either
excitation or emission, but unlike a monochromator, they can only pass a
specific wavelength band, not a continuously variable one.
55.Question: When an excited molecule undergoes intersystem crossing, it
transitions from a singlet excited state to a:
o A. Ground singlet state.
o B. Triplet excited state.
o C. Different singlet excited state.
o D. Ground triplet state.
o Correct Answer: B. Triplet excited state.
o Rationale: Intersystem crossing is a non-radiative process that involves a
change in the electron's spin state from a singlet to a triplet state.
56.Question: The intensity of scattered light in nephelometry is directly
proportional to the:
o A. Molar absorptivity of the particles.
o B. Wavelength of the incident light.
o C. Concentration of the suspended particles.
o D. Temperature of the suspension.
o Correct Answer: C. Concentration of the suspended particles.
o Rationale: Nephelometry is used to quantify the concentration of
suspended particles by measuring the amount of scattered light, which is
directly proportional to their concentration in a dilute solution.
57.Question: What is the main disadvantage of a turbidimeter compared to a
nephelometer?
o A. It is more expensive.
o B. It is less sensitive to low concentrations of particles.
o C. It cannot be used with colored samples.
o D. It requires a more powerful light source.
o Correct Answer: B. It is less sensitive to low concentrations of particles.
o Rationale: Turbidimetry measures a small decrease in a large signal,
making it less sensitive to low concentrations than nephelometry, which
measures a small signal against a dark background.
58.Question: Which of the following is a common application of nephelometry in
clinical analysis?
o A. Measuring the concentration of blood alcohol.
o B. Quantifying specific proteins in blood serum (immunochemical
assays).
o C. Determining the pH of a blood sample.
o D. Measuring the concentration of hemoglobin.
o Correct Answer: B. Quantifying specific proteins in blood serum
(immunochemical assays).
o Rationale: Nephelometry is used in immunochemical assays where
antibodies and antigens react to form a suspension of particles, and the
concentration of the specific protein can be determined by measuring the
scattered light.
59.Question: The excitation spectrum of a fluorophore is a plot of:
o A. Fluorescence intensity versus emission wavelength.
o B. Fluorescence intensity versus excitation wavelength.
o C. Absorbance versus wavelength.
o D. Emitted light intensity versus time.
o Correct Answer: B. Fluorescence intensity versus excitation wavelength.
o Rationale: The excitation spectrum is measured by monitoring the
fluorescence at a fixed emission wavelength while scanning the excitation
wavelength. It should ideally match the absorption spectrum.
60.Question: In turbidimetry, the measured signal is typically expressed as:
o A. Fluorescence units.
o B. Nephelometric Turbidity Units (NTU).
o C. Absorbance.
o D. Relative light intensity.
o Correct Answer: C. Absorbance.
o Rationale: A turbidimeter measures the decrease in transmitted light,
which is directly analogous to an absorbance measurement on a
spectrophotometer.
61.Question: Which of the following best describes the process of Rayleigh
scattering?
o A. Scattering of light by particles much larger than the wavelength of the
light.
o B. Scattering of light by particles much smaller than the wavelength of
the light.
o C. Scattering that occurs only at a 90∘ angle.
o D. Scattering that is dependent on the color of the particles.
o Correct Answer: B. Scattering of light by particles much smaller than
the wavelength of the light.
o Rationale: Rayleigh scattering applies to very small particles, where the
scattering intensity is inversely proportional to the fourth power of the
wavelength.
62.Question: Why are turbidimeters and nephelometers calibrated using a standard
of known turbidity?
o A. To measure the molecular weight of the particles.
o B. To establish a relationship between the instrument reading and the
particle concentration.
o C. To determine the size of the particles.
o D. To correct for the color of the sample.
o Correct Answer: B. To establish a relationship between the instrument
reading and the particle concentration.
o Rationale: Calibration is essential to convert the measured light signal
(in NTU or other units) into a meaningful concentration value for the
suspended particles.
63.Question: Which of the following can lead to non-linearity in a fluorescence
calibration curve?
o A. Inner filter effect.
o B. Collisional quenching.
o C. Self-quenching.
o D. All of the above.
o Correct Answer: D. All of the above.
o Rationale: All these phenomena are concentration-dependent and cause
deviations from the expected linear relationship between fluorescence
intensity and concentration at higher analyte levels.
64.Question: In a fluorimeter, what is the purpose of the emission
monochromator?
o A. To select the wavelength of light that excites the sample.
o B. To measure the concentration of the analyte.
o C. To separate the emitted fluorescence from other light and select a
specific emission wavelength for the detector.
o D. To focus the light from the source onto the sample.
o Correct Answer: C. To separate the emitted fluorescence from other
light and select a specific emission wavelength for the detector.
o Rationale: The emission monochromator is positioned between the
sample and the detector to isolate the specific fluorescence emission
wavelength of interest while rejecting any scattered light or other
unwanted signals.
65.Question: A major advantage of fluorescence spectroscopy is that it can
provide information about the molecular environment. This is possible because
fluorescence is sensitive to:
o A. Temperature, pH, and solvent polarity.
o B. Molecular weight.
o C. The elemental composition of the sample.
o D. The boiling point of the solvent.
o Correct Answer: A. Temperature, pH, and solvent polarity.
o Rationale: The quantum yield and emission spectrum of a fluorophore
are sensitive to its local environment, allowing for studies of molecular
interactions, protein folding, and membrane dynamics.
66.Question: When a fluorophore is excited and then non-radiatively decays from
a higher excited state to the lowest excited state (S1), this process is called:
o A. Intersystem crossing.
o B. Vibrational relaxation.
o C. Quenching.
o D. Internal conversion.
o Correct Answer: D. Internal conversion.
o Rationale: Internal conversion is the non-radiative process that brings the
molecule from a higher electronic state to a lower one of the same spin
multiplicity.
67.Question: Which of the following is a common application of fluorimetry in
environmental science?
o A. Measuring the concentration of a heavy metal.
o B. Detecting trace amounts of organic pollutants like polyaromatic
hydrocarbons (PAHs) in water.
o C. Measuring the conductivity of water.
o D. Quantifying the hardness of water.
o Correct Answer: B. Detecting trace amounts of organic pollutants like
polyaromatic hydrocarbons (PAHs) in water.
o Rationale: Many PAHs are naturally fluorescent, and fluorimetry's high
sensitivity makes it ideal for detecting them at very low concentrations in
water samples.
68.Question: In turbidimetry, the relationship between the measured absorbance
(A) and the concentration (C) of the suspended particles is best described by the
equation:
o A. A=ϵbC.
o B. A=kC.
o C. A=kI0.
o D. A=kIs.
o Correct Answer: A. A=ϵbC.
o Rationale: The measurement in turbidimetry is treated as an absorbance,
which formally follows the Beer-Lambert Law, even though the
attenuation is due to scattering, not true absorption.
69.Question: What is the main difference between a filter fluorimeter and a
spectrofluorimeter in terms of their wavelength selection components?
o A. A filter fluorimeter uses filters, while a spectrofluorimeter uses prisms
or gratings.
o B. A filter fluorimeter uses monochromators, while a spectrofluorimeter
uses filters.
o C. Both use filters, but a spectrofluorimeter has more of them.
o D. A filter fluorimeter uses a single light source, while a
spectrofluorimeter uses two.
o Correct Answer: A. A filter fluorimeter uses filters, while a
spectrofluorimeter uses prisms or gratings.
o Rationale: Filter fluorimeters use fixed filters, whereas
spectrofluorimeters use dispersive elements (prisms or gratings) to select
a continuously variable range of wavelengths.
70.Question: The term scattering in nephelometry refers to:
o A. The absorption of light by suspended particles.
o B. The deflection of a light beam by particles in all directions.
o C. The change in wavelength of light upon contact with a substance.
o D. The emission of light by a substance.
o Correct Answer: B. The deflection of a light beam by particles in all
directions.
o Rationale: Scattering is the process by which light is redirected by
particles in a suspension, which is the basis for nephelometry.
71.Question: Which of the following is a major advantage of nephelometry
compared to turbidimetry for measuring a suspension of very fine particles?
o A. It is less affected by multiple scattering.
o B. It measures a signal against a zero background.
o C. It has a wider linear range.
o D. It is more sensitive to a change in particle color.
o Correct Answer: B. It measures a signal against a zero background.
o Rationale: In nephelometry, the signal from the scattered light is
measured against a background of no light (in an ideal system), which
allows for greater sensitivity to the presence of a few particles.
72.Question: What is the primary cause of the Stokes shift in fluorimetry?
o A. Absorption of light by the solvent.
o B. Collisional deactivation.
o C. Non-radiative energy loss, such as vibrational relaxation, in the excited
state.
o D. Quenching by impurities.
o Correct Answer: C. Non-radiative energy loss, such as vibrational
relaxation, in the excited state.
o Rationale: After excitation, the molecule quickly loses some of its
energy as heat through vibrational relaxation before fluorescing from the
lowest vibrational level of the excited state, leading to the emission of a
lower-energy (longer-wavelength) photon.
73.Question: In the instrumentation for both turbidimetry and nephelometry, the
light source should be:
o A. A continuous, high-intensity source.
o B. A pulsed laser source.
o C. A mercury vapor lamp.
o D. A low-intensity, monochromatic source.
o Correct Answer: A. A continuous, high-intensity source.
o Rationale: A continuous, high-intensity source is needed to provide a
stable and strong signal, which is critical for accurate measurements in
both techniques.
74.Question: Which of the following factors can affect the intensity of scattered
light in nephelometry?
o A. The wavelength of the incident light.
o B. The concentration of the particles.
o C. The size and shape of the particles.
o D. All of the above.
o Correct Answer: D. All of the above.
o Rationale: The intensity of scattered light is a complex function of the
properties of the particles themselves (size, shape, concentration) and the
incident light (wavelength).
75.Question: What is the primary purpose of a photomultiplier tube (PMT) in a
fluorimeter?
o A. To select a specific wavelength.
o B. To amplify the weak fluorescence signal.
o C. To filter out scattered light.
o D. To provide the excitation light.
o Correct Answer: B. To amplify the weak fluorescence signal.
o Rationale: The PMT's cascade of dynodes allows it to multiply the
electrical current produced by a single photon, making it extremely
sensitive to the low light levels of fluorescence.
76.Question: The term quantum yield of a fluorophore is also known as its
fluorescence efficiency and is a measure of the number of photons emitted for
every photon absorbed. A fluorophore with a quantum yield of 1.0 would mean:
o A. No light is absorbed.
o B. All absorbed photons are emitted as fluorescence.
o C. No fluorescence is emitted.
o D. It has no linear range.
o Correct Answer: B. All absorbed photons are emitted as fluorescence.
o Rationale: A quantum yield of 1.0 indicates that every photon absorbed
results in the emission of a fluorescence photon, which is the theoretical
maximum efficiency.
77.Question: In a turbidimetric measurement, the pathlength of the sample cell can
affect the measurement. This relationship is described by:
o A. The Luminescence Law.
o B. Beer's Law.
o C. Rayleigh's Law.
o D. The Stokes shift.
o Correct Answer: B. Beer's Law.
o Rationale: Similar to absorption, the attenuation of light in a turbid
solution is dependent on the pathlength of the cuvette, as described by
Beer's Law.
78.Question: A major limitation of turbidimetry is that it can only be used with
samples that are:
o A. Colorless.
o B. In a gaseous state.
o C. Highly concentrated.
o D. Homogeneous.
o Correct Answer: A. Colorless.
o Rationale: Turbidimetry is a measure of light attenuation by scattering,
and if the sample is colored, the absorption of light by the color can
interfere with and invalidate the turbidity measurement.
79.Question: The scattered light in nephelometry is most intense at:
o A. The same wavelength as the incident light.
o B. A longer wavelength than the incident light.
o C. A shorter wavelength than the incident light.
o D. A randomly selected wavelength.
o Correct Answer: A. The same wavelength as the incident light.
o Rationale: Scattering is a physical process that deflects light without
changing its wavelength, so the scattered light has the same wavelength
as the incident light.
80.Question: What is the main difference between fluorescence and
phosphorescence?
o A. Fluorescence is a non-radiative process, while phosphorescence is
radiative.
o B. Fluorescence occurs from a singlet state, while phosphorescence
occurs from a triplet state.
o C. Phosphorescence is instantaneous, while fluorescence is delayed.
o D. Fluorescence has a longer wavelength than phosphorescence.
o Correct Answer: B. Fluorescence occurs from a singlet state, while
phosphorescence occurs from a triplet state.
o Rationale: Fluorescence is the result of a spin-allowed transition from a
singlet excited state, while phosphorescence is the result of a spin-
forbidden transition from a triplet excited state.
81.Question: Which of the following statements about fluorimetry is true?
o A. It is generally less sensitive than absorption spectroscopy.
o B. It measures the amount of light absorbed by a sample.
o C. The excitation spectrum of a compound is independent of its emission
spectrum.
o D. It can be used to study dynamic molecular interactions.
o Correct Answer: D. It can be used to study dynamic molecular
interactions.
o Rationale: The sensitivity of fluorescence to its molecular environment
makes it a powerful tool for studying processes like protein-ligand
binding, conformational changes, and membrane dynamics.
82.Question: What is a common application of nephelometry in environmental
monitoring?
o A. Measuring the concentration of dissolved oxygen.
o B. Monitoring the turbidity of a river after rainfall.
o C. Measuring the amount of dissolved CO2.
o D. Analyzing the pH of a soil sample.
o Correct Answer: B. Monitoring the turbidity of a river after rainfall.
o Rationale: Rainfall can introduce suspended solids into a river,
increasing its turbidity. Nephelometry is an excellent method for
continuously monitoring this change in water quality.
83.Question: The fluorescence lifetime of a molecule is defined as the average
time a molecule spends in the:
o A. Ground state before excitation.
o B. Excited state before returning to the ground state.
o C. Triplet state before returning to the ground state.
o D. Ground state after fluorescence.
o Correct Answer: B. Excited state before returning to the ground state.
o Rationale: The fluorescence lifetime is the average time a fluorophore
remains in the excited state before returning to the ground state by
emitting a photon.
84.Question: Which of the following is an example of an inorganic material that
can be analyzed by fluorimetry?
o A. Lead ions (Pb2+).
o B. Copper ions (Cu2+).
o C. Zinc ions (Zn2+).
o D. Sulfate ions (SO42−).
o Correct Answer: C. Zinc ions (Zn2+).
o Rationale: While some inorganic ions can be directly fluorescent, many
are analyzed by reaction with a fluorescent chelating agent to form a
complex. Zinc ions are known to form fluorescent complexes with certain
ligands.
85.Question: In turbidimetry, if the concentration of suspended particles becomes
very high, the measured absorbance will:
o A. Increase linearly with concentration.
o B. Increase non-linearly and eventually level off.
o C. Decrease linearly with concentration.
o D. Decrease non-linearly.
o Correct Answer: B. Increase non-linearly and eventually level off.
o Rationale: At high concentrations, multiple scattering and other effects
lead to a deviation from Beer's Law, causing the measured absorbance to
increase less than linearly and eventually plateau.
86.Question: What is the primary disadvantage of using a filter fluorimeter?
o A. Its high cost.
o B. Its lack of sensitivity.
o C. It cannot perform a full fluorescence spectrum scan.
o D. It requires a complex light source.
o Correct Answer: C. It cannot perform a full fluorescence spectrum scan.
o Rationale: A filter fluorimeter uses fixed filters for wavelength selection,
which means it cannot be used to generate a continuous spectrum like a
spectrofluorimeter.
87.Question: The intensity of scattered light in nephelometry is at its maximum at
which angle, relative to the incident light?
o A. 0∘ (transmitted light).
o B. 90∘.
o C. 180∘ (back-scattered).
o D. The angle depends on particle size.
o Correct Answer: D. The angle depends on particle size.
o Rationale: For very small particles (Rayleigh scattering), the scattering is
symmetrical in the forward and backward directions. For larger particles
(Mie scattering), the scattering is predominantly in the forward direction.
88.Question: What is the main cause of the inner filter effect in fluorimetry?
o A. Light scattering by the solvent.
o B. Absorption of light by the cuvette walls.
o C. The high concentration of the analyte, leading to reabsorption of light.
o D. The presence of impurities that quench fluorescence.
o Correct Answer: C. The high concentration of the analyte, leading to
reabsorption of light.
o Rationale: At high concentrations, the analyte itself acts as a filter,
absorbing both the excitation light before it reaches the entire sample and
the emitted light before it reaches the detector.
89.Question: Which of the following best describes the principle of operation for a
turbidimeter?
o A. It measures the light emitted by a sample.
o B. It measures the light scattered at a 90∘ angle.
o C. It measures the light that passes through the sample without being
scattered.
o D. It measures the light absorbed by the solvent.
o Correct Answer: C. It measures the light that passes through the sample
without being scattered.
o Rationale: Turbidimetry is a measure of the light transmitted through a
suspension, which is inversely related to the amount of scattering and
absorption.
90.Question: What is the unit typically used to express turbidity?
o A. Molarity (M).
o B. Parts per million (ppm).
o C. Nephelometric Turbidity Units (NTU).
o D. Absorbance units (AU).
o Correct Answer: C. Nephelometric Turbidity Units (NTU).
o Rationale: NTU is the standard unit for expressing turbidity, especially
for water quality measurements, as it is derived from a nephelometric
measurement principle.
91.Question: Which of the following is a key advantage of fluorimetry in
biological research?
o A. It can be used to determine the exact elemental composition of a
sample.
o B. It can be used to monitor the changes in protein conformation.
o C. It is very good for analyzing a wide range of inorganic compounds.
o D. It requires a high concentration of the analyte.
o Correct Answer: B. It can be used to monitor the changes in protein
conformation.
o Rationale: Many biomolecules, such as tryptophan residues in proteins,
are naturally fluorescent. Changes in their fluorescence properties can be
used to monitor changes in the protein's conformation or folding.
92.Question: Which of the following phenomena can be a source of error in a
turbidimetric measurement?
o A. The color of the suspended particles.
o B. The presence of air bubbles in the sample.
o C. The presence of multiple scattering.
o D. All of the above.
o Correct Answer: D. All of the above.
o Rationale: The color of particles, air bubbles, and multiple scattering can
all interfere with the accurate measurement of transmitted light, leading to
errors.
93.Question: What is the primary limitation of nephelometry?
o A. It is not suitable for colorless samples.
o B. It cannot be used with solid particles.
o C. The relationship between scattered light and concentration is non-
linear at high concentrations.
o D. It is not sensitive to particle size.
o Correct Answer: C. The relationship between scattered light and
concentration is non-linear at high concentrations.
o Rationale: At high concentrations, multiple scattering events lead to a
non-linear response, limiting the useful range of the technique.
94.Question: What is the main principle behind the use of a reference detector in a
fluorimeter?
o A. To measure the fluorescence of the blank solution.
o B. To normalize the sample signal against the light source intensity.
o C. To correct for the inner filter effect.
o D. To measure the light scattered by the sample.
o Correct Answer: B. To normalize the sample signal against the light
source intensity.
o Rationale: The reference detector monitors the light source intensity, and
the sample signal is divided by the reference signal to correct for any
short-term fluctuations in the lamp's output.
95.Question: In the context of fluorimetry, phosphorescence is a type of
luminescence that involves a transition from a:
o A. Triplet excited state to a ground singlet state.
o B. Singlet excited state to a triplet state.
o C. Singlet excited state to a ground singlet state.
o D. Ground singlet state to a triplet excited state.
o Correct Answer: A. Triplet excited state to a ground singlet state.
o Rationale: Phosphorescence is the radiative decay from a triplet excited
state back to the ground singlet state.
96.Question: Why is a fluorimeter generally more selective than a
spectrophotometer?
o A. It uses a laser as a light source.
o B. It requires a substance to both absorb and emit light.
o C. It measures light at a single wavelength.
o D. It can only analyze colorless solutions.
o Correct Answer: B. It requires a substance to both absorb and emit light.
o Rationale: The combined requirement of a specific absorption profile
and a specific emission profile makes fluorimetry much more selective, as
not all compounds that absorb light will fluoresce.
97.Question: What is the primary application of nephelometry in the
pharmaceutical industry?
o A. Measuring the pH of a solution.
o B. Determining the potency of a drug.
o C. Monitoring the clarity of final products or measuring the concentration
of suspended particles.
o D. Analyzing the elemental composition of a tablet.
o Correct Answer: C. Monitoring the clarity of final products or
measuring the concentration of suspended particles.
o Rationale: Nephelometry is used to ensure the quality and clarity of
liquid pharmaceutical products and to measure the concentration of
suspended particles in suspensions.
98.Question: When an excited fluorophore undergoes non-radiative decay, what
happens to the energy?
o A. It is released as a photon.
o B. It is released as heat.
o C. It is stored in the molecule's bonds.
o D. It is transferred to the solvent molecules.
o Correct Answer: B. It is released as heat.
o Rationale: Non-radiative decay involves the dissipation of the excited
state energy as heat, often through vibrational relaxation or collisional
processes.
99.Question: In turbidimetry, the measured signal is related to the concentration of
the suspended particles. This relationship is often expressed as:
o A. Absorbance vs. Concentration.
o B. Fluorescence vs. Concentration.
o C. Wavelength vs. Intensity.
o D. Scattered Light vs. Concentration.
o Correct Answer: A. Absorbance vs. Concentration.
o Rationale: While the principle is scattering, the measurement is typically
conducted on a spectrophotometer and presented as a plot of absorbance
against concentration.
100. Question: What is the major limitation of using a filter fluorimeter as
opposed to a spectrofluorimeter?
* A. It is less sensitive.
* B. It can only be used with a limited number of fluorescent compounds.
* C. It cannot distinguish between fluorescence and phosphorescence.
* D. It requires a more complex setup.
* Correct Answer: B. It can only be used with a limited number of fluorescent
compounds.
* Rationale: Since filters only allow a fixed wavelength, a filter fluorimeter can
only be used with compounds that absorb and emit at those specific
wavelengths, limiting its versatility compared to a spectrofluorimeter.