ABBREVIATIONS SYMBOLS & LEGENDS PROJECT GENERAL NOTES

603 Munger Ave, Suite 130


ARCHITECTURAL DRAWING SYMBOLS

pflugerarchitects.com
A EJ EXPANSION JOINT M.C. MEDICINE CABINET
1. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE A WATERTIGHT & WEATHERTIGHT BUILDING

Dallas, Texas 75202


A.F.F. ABOVE FINISH FLOOR EXT. EXTERIOR MEMB. MEMBRANE T
ACC.FL. ACCESS FLOOR EPS EXTRUDED POLY STYRENE MTL. METAL TB. TACK BOARD
2. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE A PLUM, LEVEL AND SQUARE STRUCTURE UNLESS OTHERWISE NOTED ANY DEVIATION FROM THIS GENERAL INTENT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION
A.P. ACCESS PANEL MFD. METAL FLOOR DECK TK. STP. TACK STRIP
ACOUS. ACOUSTICAL F MRD. METAL ROOF DECK TEL. TELEPHONE Name 3. THE BUILDING SHALL BE CONSTRUCTED IN FULL COMPLIANCE WITH ALL THE APPLICABLE CODES, ORDINANCES AND REGULATIONS AS WELL AS THE DRAWINGS & SPECIFICATION. ANY CODE DEFICIENCIES IN THE DRAWINGS RECOGNIZED BY THE CONTRACTOR SHOULD BE
101 ROOM TAG WITH ROOM FINISH AB COLUMN GRID
ACT. ACOUSTICAL CEILING TILE FAB FABRICATED M. THR. METAL THRESHOLD TV TELEVISION BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION
F1|W1|C1
ADD. ADDENDUM FV. FIELD VERIFY MWK. MILLWORK THK. THICK
ADJNT. ADJACENT FIN. FINISH MIN. MINIMUM THR. THRESHOLD 4. THE CONTRACTOR SHALL VISIT PROJECT SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE OF WORK AND TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BIDDING. ANY AMBIGUOUS ITEMS OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
Name ROOM TAG WITH OCCUPANCY ARCHITECT IN WRITING PRIOR TO SUBMITTING PROPOSAL.
ADJ. ADJUSTABLE FIN. FLR. FINISH FLOOR MIR. MIRROR TO. COL. TOP OF COLUMN 101 5' DIAMETER ADA TURN AROUND
XXX SF/ XXX(P) SF=SQUARE FEET
ADMIN. ADMINISTRATION FFE FINISH FLOOR ELEVATION MISC. MISCELLANEOUS T.O.C. TOP OF CONCRETE 5. THE CONTRACTOR IS TO COMPLY WITH FEDERAL, STATE, AND LOCAL CODES REQUIREMENTS, AND COMPLETE TEXAS HEALTH DEPARTMENT NOTIFICATIONS AND SUBMIT FORMS AND REQUIRED INFORMATION TO MEET " TEXAS COMMISSION ON ENVIRONMENTAL QUALITY"
P=PEOPLE
AGG. AGGREGATE F.T.F. FINISH TO FINISH MOD. MODULAR T.O.F. TOP OF FOOTING (TCEQ) REQUIREMENTS PRIOR TO START OF PROJECT
1 REVISION TAG
A/C AIR CONDITIONING FA. FIRE ALARM MLDG. MOLDING T.O.J. TOP OF JOIST
101 DOOR TAG 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF THE BUILDING ON THE SITE AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. DISCREPANCIES BETWEEN DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE
ALT. ALTERNATE, ALTERNATIVE FDC FIRE DEPARTMENT CONNECTION MT. MOUNT T.O.P. TOP OF PARAPET
ALUM. ALUMINUM FE. FIRE EXTINGUISHER MTD. MOUNTED T.O.S. TOP OF STEEL REVISION CLOUD ATTENTION OF THE ARCHITECT BEFORE BIDDING THE PROJECT OR THE COMMENCEMENT OF WORK. THE OWNER SHALL NOT BE RESPONSIBLE FOR CHANGES TO THE WORK DUE TO THE FAILURE OF THE CONTRACTOR TO FAMILIARIZE HIS/HER SELF WITH EXISTING
CONDITIONS
ANCH. ANCHOR, ANCHORAGE FEC. FIRE EXTINGUISHER CABINET MOV. MOVE TG. TOUNG AND GROOVE
ANOD. ANODIZED FHS. FIRE HOSE CABINET MULL. MULLION TR. TREAD AX PARTITION TAG
7. DO NOT SCALE DRAWINGS: ALL DIMENSIONS SHALL HAVE PREFERENCE OVER SCALE AND BE FIELD VERIFIED AND COORDINATED WITH WORK OF ALL TRADES. IF NO DIMENSIONS ARE GIVEN OR DISCREPANCIES FOUND, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
APPROX. APPROXIMATE FPL. FIRE PLACE TYP. TYPICAL ALIGN FOR CLARIFICATION BEFORE BIDDING OR COMMENCING THE WORK.
ALIGN FACES
ARCH. ARCHITECT FP. FIRE PROOFING N 1 HOLLOW METAL FRAME TAG
A.D. AREA DRAIN FRC. FIRE RESISTANT COATING NAT. NATURAL U 8. DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF ACCOMPLISHING WORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, ALL INCLUDED AS PART OF THE WORK.
1 ALUMINUM FRAME TAG NOTE BY NUMBER - SHAPE MAY VARY
ASPH. ASPHALT F. RT. FIRE RETARDANT NR. NOISE REDUCTION UC. UNDER CUT
9. THE CONTRACTOR SHALL PROVIDE ALL PERMITS AND INSPECTIONS NECESSARY FOR THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH APPLICABLE CODES AND GOVERNING REGULATIONS
AUTO. AUTOMATIC FLSHG. FLASHING NOM. NOMINAL UNFIN. UNFINISHED
FLEX FLEXIBLE N. NORTH UNO UNLESS NOTED OTHERWISE EXPANSION JOINT 10. THE CONTRACTOR SHALL VERIFY THE SIZES AND LOCATIONS OF ALL MECHANICAL AND ELECTRICAL EQUIPMENT PADS AND BASES, AS WELL AS POWER, WATER AND DRAIN REQUIREMENTS FOR SUCH EQUIPMENT WITH EQUIPMENT MFG. DEVIATION OF BEFORE MENTIONED
B FLR. FLOOR NIC. NOT IN CONTRACT UR. URINAL NORTH ARROW REQUIREMENTS SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION
BSMT. BASEMENT FLR. C.O. FLOOR CLEAN OUT NTS. NOT TO SCALE 21 / A101
ENLARGED CALL OUT 11. ALL INTERIOR INSULATION SHALL BE NON-COMBUSTIBLE
BM. BENCH MARK FD. FLOOR DRAIN V SIM.
BTWN. BETWEEN FLR. JT. FLOOR JOINT O VB. VAPOR BARRIER EXIT POINT WITH WIDTH INDICATED IN INCHES 12. ALL WINDOW OPENING SILL FLASHING SHALL BE END DAMMED
P RO

OCC
BEV. BEVEL FLR. PLT. FLOOR PLATE OC. ON CENTER VAR. VARIES OCCUPANT LOAD SHOWN VERTICAL
SIM R EQ
BIT. BITUMINOUS FLOUR. FLUORESCENT OCEW ON CENTER EACH WAY VNR. VENEER 1 BUILDING SECTION TAG P=PROVIDED EXIT WIDTH OF EGRESS COMPONENT 13. PROVIDE FIRE STOPS WHEREVER INTERIOR AND EXTERIOR WALLS AND PARTITIONS INTERSECT FLOORS, CEILINGS, AND ROOFS. ALSO PROVIDE AT ALL OPENINGS AROUND PENETRATIONS TO PREVENT VERTICAL & HORIZONTAL COMMUNICATION OF FIRE ALONG LINES OF
BLK. BLOCKING FTG. FOOTING OPG. OPENING VIF VERIFY IN FIELD A101 R=REQUIRED EXIT WIDTH OF EGRESS COMPONENT CORRIDORS, OCCUPANCY CHANGES, AND SIMILAR SEPARATIONS.
BD. BOARD FRMG. FRAMING OPP. OPPOSITE VERT. VERTICAL
SIM FIRE EXTINGUISHER CABINET 14. ALL WALL WIDTHS ARE SHOWN AND DIMENSIONED WITH ACTUAL DIMENSIONS. DIMENSIONS FOR FRAMED WALLS ARE SHOWN TO FACE OF STUDS AND/OR FACE OF BLOCK U.N.O.
B.S. BOTH SIDES FBO. FURNISHED BY OWNER OH OPPOSITE HAND VG. VERTICAL GRAIN 1 WALL SECTION TAG FEC
B.W. BOTH WAYS FURR. FURRED (ING) OH. OPPOSITE HAND VIN. VINYL A101 15. CONTRACTOR IS TO PROVIDE BLOCKING AS REQUIRED FOR PROPER SUPPORT OF WALL AND CEILING MOUNTED EQUIPMENT
B.O.D. BOTTOM OF DECK FUT. FUTURE O.A. OVER ALL VIN. B. VINYL BASE FIRE EXTINGUISHER
SIM
BRK. BRACKET FRIG. REFRIGERATOR OVRHD. OVER HEAD VCT VINYL COMPOSITION TILE 1 16. CONTRACTOR IS TO DOUBLE- UP METAL STUDS AT ALL DOOR OR CASED OPENINGS
A101
DETAIL SECTION TAG FE
BRZ. BRONZE OFCI OWNER FURNISHED CONTRACTOR VIN. F. VINYL FABRIC
INSTALLED CENTER LINE 17. VERIFY ALL DIMENSIONS BEFORE ORDERING MATERIALS AND PROCEEDING WITH THE WORK
BLDG. BUILDING G VIN. T. VINYL TILE
BUR. BUILT UP ROOFING GALV. GALVANIZED OFOI OWNER FURNISHED OWNER INSTALLED Ref
18. ALL CONSTRUCTION AND EQUIPMENT IS NEW, UNLESS NOTED OTHERWISE
GSKT. GASKET W 20 EXTERIOR ELEVATION TAG
A101 MATCH LINE
C GA. GAUGE P WSCT. WAINSCOT 19. WHERE APPLICABLE, INSTALL ACCESS PANELS FOR VALVES, DAMPERS,CONTROLS, ETC. AND OTHERWISE INDICATED. COORDINATE WITH ARCHITECT & MEP ENGINEER PRIOR TO SELECTION AND INSTALLATION
CAB. CABINET GC. GENERAL CONTRACTOR PNT. PAINT WH. WALL HUNG ITEM SHOWN IS ABOVE/BELOW OR
PTD. PAINTED TO BE REMOVED(ON DEMO SHTS) U.N.O. 20. DIFFUSERS, LIGHT FIXTURES, ETC., ARE INDICATED ON THE REFLECTED CEILING PLAN FOR LOCATION AND COORDINATION. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
CPT. CARPET GLS. GLASS WC. WATER CLOSET INTERIOR ELEVATION TAG
PNL. PANEL 1/ A101 Ref PROPERTY LINE
CSMT. CASEMENT GL. BLK. GLASS BLOCK WPRF. WATER PROOFING 21. PROVIDE MARKERBOARDS AND TACKBOARDS IN NEW CLASSROOMS, REFERENCE FLOOR PLANS FOR SIZES AND LOCATIONS. REFERENCE INTERIOR ELEVATION FOR MOUNTING HEIGHTS.
CIP. CAST IN PLACE CONCRETE GL. CMU. GLAZED CONCRETE MASONRY UNIT PB. PANIC BAR WRP. WATER REPELLENT 15/ A 9.24 VIEW REFERENCE DETAIL
C.B. CATCH BASIN GST. GLAZED STRUCTURAL TILE PTDIS. PAPER TOWEL DISPENSER WS. WATER STOP BREAK LINE 22. COORDINATE ROOF PENETRATIONS WITH M.E.P. DRAWINGS-PENETRATIONS SHALL BE FLASHED TO MEET " SMACNA" DETAIL REQUIREMENTS
CLG. CEILING GB. GRAB BAR PTR. PAPER TOWEL RECEPTACLE WWF. WELDED WIRE FABRIC
CLG. HT. CEILING HEIGHT GBLK. GREEN BLOCK PAR. PARALLEL WWM. WELDED WIRE MESH 23. WHERE DISSIMILAR MATERIALS MEET, PROVIDE BACKER ROD AND SEALANT TO SEAL JOINT, TYPICAL AROUND ENTIRE CAMPUS
CEM. CEMENT GRT. GROUT PKG. PARKING W. WEST LONGEST TRAVEL DISTANCE TO EXIT
24. CLASSROOM FURNITURE INDICATED ON THE FLOOR PLANS, NOT INDICATED AS "BUILT-IN", ARE NOT IN PROJECT CONTRACT. FURNITURE IS SHOWN FOR TYPICAL CLASSROOM ARRANGEMENT, ONLY.

CORNER OF . WADLEY AVENUE AND N. FAIRGROUNDS ROAD


CL CENTERLINE GYPCTE. GYPCRETE P. BD. PARTICLE BOARD WDW. WINDOW
CT CERAMIC TILE GYP. PL. GYPSUM PLASTER PARTN. PARTITION WGLS. WIRE GLASS 25. WHERE EXISTING OR NEW EXPANSION JOINTS ARE EXPOSED DUE TO NEW CONSTRUCTION OR RENOVATION, PROVIDE APPROVED FLOOR, WALL, AND/OR CEILING EXPANSION JOINT COVER ASSEMBLIES AS REQUIRED.
PVT. PAVEMENT BUILDING EXIT
C.O. CLEAN OUT GYP. T. GYPSUM TILE WM. WIRE MESH
CLR. CLEAR(ANCE) GWB. GYPSUM WALL BOARD PERF. PERFORATED W/. WITH Elevation ELEVATION/ LEVEL TAG 26. CONTRACTOR IS TO ENSURE THAT NEW MECHANICAL, ELECTRICAL, DATA, AND CONTROL SYSTEMS ARE CONCEALED TO THE GREATEST EXTENT AS POSSIBLE UNLESS OTHERWISE NOTED
CLO. CLOSET PERIM. PERIMETER WO. WITHOUT Name
PLAS. PLASTER 27. CONTRACTOR SHALL CROSS REFERENCE STRUCTURAL COMPONENT DIMENSIONS WITH STRUCTURAL DRAWINGS AND NOTIFY ARCHITECT OF DISCREPANCIES PRIOR TO INSTALLATION.
COL. COLUMN H WD. WOOD
PLAM PLASTIC LAMINATE

MIDLAND HIGH SCHOOL


COMPT. COMPARTMENT HD. BD. HARD BOARD WD. B. WOOD BASE O.P.P ORIGIN POINT OF PATTERN 28. ALL EXPOSED METALS EXCEPT GALVANIZED AND PRE-FINISHED ITEMS, SHALL BE FINISH PAINTED - COLOR TO BE SELECTED BY ARCHITECT. REF SPECS FOR FIELD WELDS AT GALV.
COMPR. COMPRESS HD. JT. HARD JOINT PL. PLATE W. PT. WORKING POINT
COMP. COMPUTER HDW. HARDWARE PLY. PLYWOOD
CONC. CONCRETE HDWD. HARDWOOD PVC. POLYVINYL CHLORIDE
CMU. CONCRETE MASONRY UNIT HDR. HEADER PREFAB. PREFABRICATED
CONST. CONSTRUCTION HTG. HEATING PREFIN. PREFINISHED
CONT CONTINUOUS HVAC. HEATING, VENTILATION, AIR P.L. PROPERTY LINE
CONTR. CONTRACT/CONTRACTOR CONDITIONING
CFCI CONTRACTOR FURNISHED/ HVY. D. HEAVY DUTY Q

C.J.
CONTRACTOR INSTALLED
CONTROL JOINT
HT.
HC.
HEIGHT
HOLLOW CORE
QT. QUARRY TILE
WALL LEGEND
CPR. COPPER HM. HOLLOW METAL R
CG. CORNER GUARD HORIZ. HORIZONTAL RAD. RADIUS METAL STUD PARTITION

NEW CONSTRUCTION
CORR. CORRIDOR HB. HOSE BIB REF. REFERENCE
CTR. COUNTER HWH. HOT WATER HEATER RFL. REFLECTED CMU PARTITION

MIDLAND, TEXAS
C. FL. COUNTER FLASHING HR. HOUR REG. REGISTRAR
CTR. SNK. COUNTER SUNK REINF. REINFORCING 1 HR WALL CONSTRUCTION
CRS. COURSE I REM. REMOVE
CU. FT. CUBIC FEET INCL. INCLUDE REQ'D. REQUIRED 1 HR CMU WALL CONSTRUCTION
CU. YD. CUBIC YARD I.D. INSIDE DIAMETER RES. RESILIENT
2 HR WALL CONSTRUCTION
INSUL. INSULATION RET. RETURN
D INT. INTERIOR RA. RETURN AIR 2 HR CMU WALL CONSTRUCTION
D.P. DAMP PROOFING INTERM. INTERMEDIATE RVS. REVERSE
DPR. DAMPER INV. INVERT REV. REVISION
DL. DEAD LOAD RH. RIGHT HAND
DEMO DEMOLISH, DEMOLITION J R.O.W. RIGHT OF WAY
DEP. DEPRESS JAN JANITOR RD. ROOF DRAIN
DTL.
DIAG.
DETAIL
DIAGONAL
J.C.
JT.
JANITORS CLOSET
JOINT
RF. HT.
RFG.
ROOF HEIGHT
ROOFING MATERIALS LEGEND
DIAM. DIAMETER JF. JOINT FILLER RM. ROOM
DW. DISH WASHER JST. JOIST RO. ROUGH OPENING EARTH ( COMPACTED)
Autodesk Docs://24-001 Midland ISD - 2 New HS/24-001_ARCH_CORE_MISD2HS_R24.rvt

615 W. MISSOURI AVENUE


DISPR. DISPENSER RB. RUBBER BASE
DIV. DIVISION K

MIDLAND, TEXAS 79701


DR. DOOR K. PL. KICK PLATE S POROUS FILL (STONE OR GRAVEL)
DBL DOUBLE KIT. KITCHEN SF. GL. SAFETY GLASS
DH. DOUBLE HUNG K.O. KNOCK OUT SCHED. SCHEDULE
CONCRETE
DN. DOWN SLNT. SEALANT

MIDLAND ISD
DS. DOWNSPOUT L STG. SEATING

SHEET NAMING CONVENTION


DRN. DRAIN LUG BRICK LUG DIMENSION SCTN. SECTION
PLASTER/SAND/CEMENT/ GROUT
DRN. BD. DRAIN BOARD LAB. LABORATORY SHTH. SHEATHING
DRN. TL. DRAIN TILE LAM. LAMINATE SHT. SHEET
DWR. DRAWER LAV. LAVATORY SH. GL. SHEET GLASS BRICK ( COMMON OR FACE)
DWG. DRAWING LH. LEFT HAND SHR. SHORING
DF DRINKING FOUNTAIN LC. LIGHT CONTROL SIM. SIMILAR
LT. WT. LIGHT WEIGHT SKYLT. SKYLIGHT CONCRETE MASONRY UNIT (CMU) DRAWING SHEET DISCIPLINE
E LT. LIGHT, RE: ELECTRICAL SLV. SLEEVE
EA EACH LT. CONC. LIGHTWEIGHT CONCRETE SC. SOLID CORE G GENERAL M MECHANICAL
METAL (LARGE SCALE) C CIVIL E ELECTRICAL
EA. FA. EACH FACE LMSTN LIMESTONE SCW SOLID CORE WOOD

A02.XYZ
L LANDSCAPE, IRRIGATION FA FIRE ALARM
E. EAST LTL. LINTEL S. SOUTH S STRUCTURAL T TECHNOLOGY
ELEC. ELECTRIC LL. LIVE LOAD SPCR. SPACER A ARCHITECTURE AV AUDIO VISUAL
METAL (SMALL SCALE)
EDF. ELECTRIC DRINKING FOUNTAIN LB. LOAD BEARING SPKR. SPEAKER FP FIRE PROTECTION TE THEATRICAL
EP. ELECTRICAL PANEL LPT. LOW POINT SPEC. SPECIFICATIONS P PLUMBING FS FOOD SERVICE
ELEV. ELEVATION SQ. SQUARE BATT INSULATION
EMERG. EMERGENCY M S.S. STAINLESS STEEL
ENCL. ENCLOSURE MH. MAN HOLE STD. STANDARD
RIGID BOARD OR SPRAY FOAM INSULATION
FLOOR PLAN SEGMENT DESIGNATION (FLOOR PLANS ONLY)
EQ. EQUAL MFR. MANUFACTURE STA. STATION
EQUP. EQUIPMENT MRB. MARBLE STL. STEEL PLAN WING DESIGNATION OR SHEET SERIES DATE: 08/22/2025
ESC.
EXCAV.
ESCALATOR
EXCAVATE
MB
MAS.
MARKER BOARD
MASONRY
STN.
STOR.
STONE
STORAGE ROUGH WOOD (CONTINUOUS) FLOOR LEVEL OR SHEET SERIES
EXH.
EXIST.
EXHAUST
EXISTING
M.O.
MU
MASONRY OPENING
MASONRY UNIT
SD.
STRUCT.
STORM DRAIN
STRUCTURE (TURAL)
DRAWING SHEET SERIES PROJECT NO. 24-001
08/22/2025
DATE:
ROUGH WOOD (NON-CONTINUOUS)
EXP. EXPANSION MAT'L. MATERIAL SUSP. SUSPENDED DRAWN BY: DRW CHECKED BY: CHK
MAX. MAXIMUM SYM. SYMMETRICAL
REVISIONS:
MECH. MECHANICAL SYN. SYNTHETIC FINISH WOOD
MEP MECHANICAL/ELECTRICAL/ PLUMBING SYS. SYSTEM No. Date Description

PLYWOOD

BUILDING PACKAGE FOR


PERMIT
8/20/2025 5:40:42 PM

A00.00
SYMBOLS &
ABBREVIATIONS

UPDATED 08-21-21