2021-10-15 1943193
1943193 - Instructions for check monitor in EWM
Version 2 Type SAP Note
Language English Master Language German
Priority Recommendations / Additional Info Category Consulting
Release Status Released for Customer Released On 19.11.2015
Component SCM-EWM-WOP ( Warehouse Order Processing )
Please find the original document at https://launchpad.support.sap.com/#/notes/ 1943193
Symptom
This SAP Note describes the steps you have to carry out for analyzing and correcting inconsistencies in the
available stocks or the warehouse order status.
Other checks, for example, with regard to the warehouse order status can be executed in the same way.
Other Terms
/SCWM/CHM_LOG, /SCWM/CHM_PRF, /SCWM/AQUA, /SCWM/WHO, EWM, Extended Warehouse
Management
Reason and Prerequisites
Solution
• Checking inconsistencies in available stocks
1. Call transaction /SCWM/CHM_LOG.
2. Choose "Ad-Hoc".
3. On the following screen, choose "Stock and Bin" and enter the selection criteria by choosing the yellow
arrow on the right (entry of warehouse number, storage type, and storage bin as required).
4. From the checks available below this node, select "Available Quantity" and then select the line. As a
result, the system should display the bulb icon on the left.
5. At the level of the available stocks, you can optionally restrict your selection (arrow) to a transportation
unit (TU), resource, or product.
6. Make the selection using F8.
The system now checks for inconsistencies.
If there are any inconsistencies, they can be corrected by positioning the cursor on a line and right-clicking it,
provided that the relevant function supports this.
However, the selection criteria should be entered as specifically as possible. A selection that checks an entire
storage type with regard to the available stocks can be very time-consuming. In addition, you should not
execute more comprehensive selections at a time where a large number of other activities is executed.
© 2021 SAP SE or an SAP affiliate company. All rights reserved 1 of 3
2021-10-15 1943193
Software Components
Software Component Release
SCMEWM 510 - 510
SCMEWM 700 - 700
SCMEWM 701 - 701
SCMEWM 702 - 702
SCMEWM 712 - 712
SCMEWM 900 - 900
SCMEWM 910 - 910
This document refers to
SAP Note/KBA Title
1926397 Check monitor: WHO is assigned the wrong status
1910524 /scwm/chm_log: Internal error when checking available stocks
1837232 EWM check monitor: Error for checks on available quantities
1835202 CHM status check doesn't work for outbound deliveries
1833126 EWM check monitor:Release corr. function for WO structure
1791947 EWM check monitor:Release correction function for WO status
1764328 Unable to delete empty HU from check monitor log
1759182 CHM: Superfluous Links check cannot correct temporary no.
This document is referenced by
SAP Note/KBA Title
3058435 EWM Check Monitor
© 2021 SAP SE or an SAP affiliate company. All rights reserved 2 of 3