0% found this document useful (0 votes)
33 views5 pages

330D2 LEGALEM Warning Operation

The document provides operational information for the 330D2 L Excavator powered by the C7.1 engine, detailing the E Series Excavator Monitoring System. It outlines the warning levels for machine conditions, ranging from Level 1 (operator awareness) to Level 3 (immediate shutdown required), along with a list of potential warning messages. The monitoring system logs events and alerts operators to maintain safe and effective machine operation.

Uploaded by

Daniel Tekle
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views5 pages

330D2 LEGALEM Warning Operation

The document provides operational information for the 330D2 L Excavator powered by the C7.1 engine, detailing the E Series Excavator Monitoring System. It outlines the warning levels for machine conditions, ranging from Level 1 (operator awareness) to Level 3 (immediate shutdown required), along with a list of potential warning messages. The monitoring system logs events and alerts operators to maintain safe and effective machine operation.

Uploaded by

Daniel Tekle
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

330D2 L Excavator SZK00001-UP (MACHINE) POWERED BY C7.1 En...

Page 1 of 5

Shutdown SIS

Previous Screen

Product: EXCAVATOR
Model: 330D2 L EXCAVATOR SZK
Configuration: 330D2 L Excavator SZK00001-UP (MACHINE) POWERED BY C7.1 Engine

Systems Operation
E Series Excavator Monitoring System
Media Number -KENR9509-23Publication Date -01/07/2015Date Updated -26/04/2018

i05627452

Warning Operation
SMCS - 7490

Illustration 1 g03586851
Monitoring System Display
(1) Multi-Information Area

The Monitor will activate, display, and log events for machine conditions that are not
within normal operating parameters. The Monitor will detect some of the events that
are not within normal operating parameters. However, many of these events are
detected by the other control modules on the machine.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/si... 7/2/2024
330D2 L Excavator SZK00001-UP (MACHINE) POWERED BY C7.1 En... Page 2 of 5

The Monitor receives this event data from the other control modules via the CAT Data
Link. The level of the warning response will be determined depending on the severity
of the problem. The event warnings are classified into three warning levels. The
warning level determines which response is required by the operator. Warning Level 1
represents the least severe problem and Warning Level 3 represents the most severe
problem. The warning levels, monitor response, and the required operator actions are
given below.

Warning Level 1 - Graphic Display - requires operator awareness.

Warning Level 2 - Graphic Display and Action Lamp - requires a change in the
operation of the machine or a change in the maintenance of the machine to correct the
condition.

Warning Level 3 - Graphic Display, Action Lamp, and Action Alarm - requires
immediate shutdown of the machine to prevent damage to the machine or personnel.

When multiple warnings are present in the system, the highest warning level is shown
first. Press the right or left key to view all of the logged warnings. If no keys are
pressed within five seconds, the display will return to the highest level warning.

Note: All of the warnings that are listed may not be applicable to all machine models.

Table 1
Warning Messages
Security System Active
Security System Active (HESS)
Operator Override Hot Shutdown
Active Regen
Key Off Regen
Engine Cooldown Active
Service Required
Engine Fault Shutdown Safely
Inlet Air Temp Power Derate
Engine Oil Pressure Power Derate
Fuel Filter Plugged Power Derate

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/si... 7/2/2024
330D2 L Excavator SZK00001-UP (MACHINE) POWERED BY C7.1 En... Page 3 of 5

Coolant Temp High


Hydraulic Oil Temp High
DPF Level High Shutdown Safely
Starter Over Heat
ECM Error
Counterweight Removal
Quick Coupler Unlock
100% Load
Cancel Auto Stop
Lift Overload Warning
E-Fence System Backup Switch On
Limited Mobility Mode
Engine Shutdown Pending
Engine Shutdown Idle Time Exceeded
Regen Disabled
Engine Fault Check Engine
Tool Control Malfunction
Travel with Lift Out of Work Area
DPF Level High Regen Required
Engine Oil Pressure Low
Battery Voltage Irregular
Coolant Temp Power Derate
Hydraulic Oil Temp Power Derate
Hydraulic Return Filter Plugged
Water Separator Full
Attachment Filter Plugged

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/si... 7/2/2024
330D2 L Excavator SZK00001-UP (MACHINE) POWERED BY C7.1 En... Page 4 of 5

Hydraulic Oil Temp High (Tool)


Lever is not Neutral
Cycle the Lock Lever
E-Fence System Interfering
Reverse Fan Error
90% Load
Boom Out of Work Area
Stick Out of Work Area
Hook Interfering
Fuel Level Low
Bucket Cylinder Stroke End
Engine Over Speed Warning
Fuel Pressure High
Fuel Filter Plugged
Intake Air Filter Plugged
Coolant Level Low
Engine Oil Level Low
Hydraulic Oil Level Low
Check Filter/Fluid Information
Fasten Seat Belt
Regen Condition Not Met
Regen Condition Engine Temp Low
Regen System Fault
Glow Active
Low Battery Elevated Idle
Warm-Up Mode Power Derate

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/si... 7/2/2024
330D2 L Excavator SZK00001-UP (MACHINE) POWERED BY C7.1 En... Page 5 of 5

Intelligent Hammer Active


Reverse Fan Starting
Quick Coupler Locking
Verify Tool Locking
Bucket In
Crane System Off
Deceleration Area
Retract Sliding Stick

Copyright 1993 - 2024 Caterpillar Inc. Tue Jul 2 09:43:43 UTC+0300 2024
All Rights Reserved.
Private Network For SIS Licensees.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/si... 7/2/2024