MAGNAVIS® 7HF is an oil-based magnetic particle ink designed for visible wet method magnetic particle testing, offering clear indications for detecting fine and medium discontinuities. It is suitable for field testing and can be used with WCP-2 white contrast paint to enhance inspection sensitivity. The product features a low toxicity formula, works in visible light, and complies with various specifications for reliable inspection results.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views3 pages

7HF PDS

MAGNAVIS® 7HF is an oil-based magnetic particle ink designed for visible wet method magnetic particle testing, offering clear indications for detecting fine and medium discontinuities. It is suitable for field testing and can be used with WCP-2 white contrast paint to enhance inspection sensitivity. The product features a low toxicity formula, works in visible light, and complies with various specifications for reliable inspection results.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product Data Sheet

7HF

Oil-Based Visible Magnetic Particle Ink


MAGNAVIS® 7HF is a highly-sensitive, oil-based magnetic particle ink for visible wet
method magnetic particle testing. 7HF provides clear, strong indications, making it
perfect for locating fine and medium discontinuities on finished parts. It is ideal for
field testing, spot inspections and places where bulk processing is impractical.
7HF is often used with our WCP-2 white contrast paint to improve contrast and inspection sensitivity.
This process is especially suited for remote inspections of tubing, piping and large structures.

BENEFITS FEATURES
Maximise indication detection • Clear indications under visible light
• Find indications of all shapes and sizes, • Heavy particle buildup
thanks to the smallest particle on the
• Great particle mobility
market.
• Heavy buildup of highly magnetic particles • Protects parts and equipment against
aroundl leakage fields make for heavy- corrosion
contrast indications, especially when used • Superior surface wetting
with WCP-2 white contrast paint. • Very small particle size
Convenient to use • Works in visible light
• Inspect in all conditions without the need for • Oil-based formula
darkness or UV lights.
• Very low toxicity
• Available in a convenient aerosol format for
easy carrying and use in the field. • Low odour

Wide application versatility


SPECIFICATION COMPLIANCE
• Inspect a wide range of components
without fear of corrosion or specification • AMS2641
non-conformance • AMS3041
• ASM3043 (Aerosols only)
• ASME BPVC-V
• ASTM E709
• ASTM E1444/E1444M
• EN ISO 9934-2
• MIL-STD-2132

Revised: January 2023 www.magnaflux.eu


Product Data Sheet

7HF
APPLICATIONS Like all Magnaflux materials, our visible magnetic
Defect location: surface and slightly subsurface inks are closely controlled to ensure batch-to-
batch consistency, optimum process control and
Ideal for:
inspection reliability.
• Detecting fine and medium discontinuities
• Field testing
USER RECOMMENDATIONS
• Spot inspections
• In-service inspections Magnetic Particle
• Machined parts NDT Method Testing, Visible,
• Light surfaces Wet Method
• Difficult-to-reach areas Storage temperature 10oC to 30oC
Ideal for: Usage temperature* -5oC to 50oC
• Inclusions
Suspension Vehicle Carrier II
• Seams
• Shrink cracks White Contrast Paint WCP-2
• Tears Cleaner/remover SKC-S
• Laps
Accessories Centrifuge Tube
• Flakes
• Welding defects
* For use of an inspection vehicle conforming to
• Grinding cracks
AMS2641, minimum temperature is 6 °C.
• Quenching cracks
• Fatigue cracks INSTRUCTIONS FOR USE
Clean the component before testing to reduce
COMPOSITION
the risk of contamination and to provide a suit-
A suspension of magnetic particles in a high-flash able test surface.
petroleum distillate.
If the test surface is a dark colour, apply a thin
coating of a suitable white contrast paint, such as
PRODUCT PROPERTIES
WCP-2, to provide a contrasting background.
Form and colour Black liquid Before using, shake the aerosol can, or agitate
Flash point > 93 C (bulk product)
o
the ink to ensure uniformity of mix and check it
SAE sensitivity 6-7 has the correct settlement volume (1.5 - 2.4 ml).

Particle size range 0.2 - 2.0 µm Apply the ink by spraying, flooding or immersion,
depending on your chosen method (see next
Viscosity at 20oC 2.5 mm2/s page).
Density 0.8 g/cm3
Coverage 4m2 - 7m2 continued >

pH (2% solution) Neutral

Revised: January 2023 www.magnaflux.eu


Product Data Sheet

7HF
Wet continuous method PACKAGING AND PART NUMBERS
Apply the ink to all surfaces of the component
and apply a magnetising current. Remember to
stop the flow of ink before the current is switched
off, otherwise there is a risk that the force of the
ink flood may wash away indications.
008A103 (x 10)
Wet residual method
This method is generally less sensitive than the
HEALTH AND SAFETY
continuous method and is more susceptible to
rapid particle depletion and bath contamination. Review all relevant health and safety information
before using this product. For complete health
• Pre-magnetise the part to be tested.
and safety information, refer to the Safety Data
• Imerse the part in a bath of the ink.
Sheets, which are available at www.magnaflux.eu
• Remove it and allow it to drain.
• Inspect the part.
Remember to shake/agitate the ink regularly
during use to ensure uniformity of mix. If you are
using a bath and it appears contaminated, or if
it has been in use for a long time, replace the
contents.
During use, the magnetic content of any ink will
become depleted so you will need to check your
bath strength at least once each day. The most
widely-used way of checking an ink’s settlement
volume is by using a graduated ASTM pear-
shaped centrifuge tube.
After inspection, remember to completely de-
magnetise your components before cleaning,
to ensure easy removal of any residual powder
particles.